Loading...
763 ATLANTIC BLVD COMM21-0010 JM ATLANTIC BEACH, FL - M4 HOOD INSTALLATION DETAILS rev. 7-29-21_1INSTALLATION FASTENER TYPES FAN TO CURB WOOD (SG = 0.42 MIN.)STEEL (12 GAUGE MIN.) CONCRETE (2500 PSI MIN. CRACKEDCONCRETE) FASTENER 1/4"-14 X 1" SELF DRILLING SCREW (A307 OR BETTER) 3/8" DIA. ZINC PLATED LAG BOLT 1/4"-14 DRIL-FLEX SELF DRILLING SCREW 3/8" DIA. SS HILTIKWIK BOLT TZ EXPANSION ANCHOR MINIMUM THREAD PENETRATION N/A 2"12 GAUGE 2-5/16" MINIMUM EDGE DISTANCE N/A 1-1/2"3/8"3" MINIMUM END DISTANCE N/A 2-5/8"3/8"4" MINIMUM SPACING N/A 1-1/2"3/4"7" INSTALLATION FASTENER QTY CURB TO FAN WOOD STEEL CONCRETE FAN MODEL LONGSIDE SHORTSIDE TOTAL LONGSIDE SHORTSIDE TOTAL LONGSIDE PER SIDE TOTAL LONGSIDE SHORTSIDE TOTAL SCALE:AS NOTED DRAWING NO. DATE: DRAWN BY:KPL JOB NO.:OAKWELL COMPANIES, LLC.10950-60 SAN JOSE BLVD. #306JACKSONVILLE, FL 32223904-710-8391JIM@OAKWELLCOMPANIES.COMKATHLEEN@OAKWELLCOMPANIES.COMAUSTIN R. ACE, P.E.P.E.171805908 Orchard Pond. Dr.Fleming Island, FL 32003P: 904-716-3661763 ATLANTIC BLVD. UNIT CATLANTIC BEACH, FL 32233763-C 2/15/21REV.DATEBYDESCRIPTION16/10/21KPLCOOLER REPOSITIONM4 HOOD INSTALLATION DETAILS