576 COASTAL OAK LN ROW21-0069 Comcast CableOWNER:ADDRESS:CITY:STATE:ZIP:
HICKS ANTHONY R 2403 SARAGOSSA AVE JACKSONVILLE FL 32217
COMPANY:ADDRESS:CITY:STATE:ZIP:
SOUTHEAST UTILITIES 1 ENERGY PL PENSACOLA FL 32520
TYPE OF
CONSTRUCTION:
REAL ESTATE
NUMBER:ZONING:BUILDING USE
GROUP:SUBDIVISION:
169505 2035 ATLANTIC BEACH
COUNTRY CLUB UNIT 02
JOB ADDRESS:PERMIT TYPE:DESCRIPTION: VALUE OF WORK:
576 COASTAL OAK LN RIGHT OF WAY COMMERCIAL
RIGHT OF WAY
COMCAST - CABLE
REPLACEMENT $0.00
LIST OF CONDITIONS
Roll off container company must be on City approved list . Container cannot be placed on City right-of-way.
1 PUBLIC WORKS ON SITE RUNOFF INFORMATIONAL
Notes:
All runoff must remain on-site during construction.
2 PUBLIC WORKS ROLL OFF CONTAINER INFORMATIONAL
Notes:
Roll off container company must be on City approved list. Approved list can be obtained at the Building Department at City Hall. Roll off container
cannot be placed on City right-of-way.
NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property
that may be found in the public records of this county, and there may be additional permits required from other
governmental entities such as water management districts, state agencies, or federal agencies.
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN
YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT
MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU
INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE
RECORDING YOUR NOTICE OF COMMENCEMENT.
MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION.
ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING
CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES .
ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY.
1 of 2Issued Date: 1/19/2022
PERMIT NUMBER
ROW21-0069
ISSUED: 1/19/2022
EXPIRES: 4/19/2022
RIGHT OF WAY PERMIT
CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
ATLANTIC BEACH, FL 32233
FEES
DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT
TOTAL:
3 PUBLIC WORKS RIGHT OF WAY RESTORATION INFORMATIONAL
Notes:
Full right-of-way restoration, including sod, is required.
4 PUBLIC WORKS INFRASTRUCTURE INFORMATIONAL
Notes:
Any damage done to infrastructure must be repaired by Contractor.
5 PUBLIC WORKS AS-BUILT INFORMATIONAL
Notes:
Contractor must submit As-Built plans to City within 30 days after completion of project.
6 PUBLIC WORKS DEBRIS INFORMATIONAL
Notes:
Roadway must be kept free of debris, mud, dirt, etc. during and after project by Contractor. All holes that have been dug and any property that has been
disturbed must have barriers and flags placed during project by Contractor.
7 PUBLIC UTILITIES UNDERGROUND WATER SEWER UTILITIES INFORMATIONAL
Notes:
2 of 2Issued Date: 1/19/2022
PERMIT NUMBER
ROW21-0069
ISSUED: 1/19/2022
EXPIRES: 4/19/2022
RIGHT OF WAY PERMIT
CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
ATLANTIC BEACH, FL 32233
R
O
W
2
1
-
0
0
6
9
NO EXPECTED CONFLICTS
WITH OTHER UTILITIES
VICINITY MAP:
576 COASTAL OAK LN ATLANTIC BEACH FL, 32233
DUVAL COUNTY
SANTA ROSA
OKALOOSA
WALTON
HOLMES
WASHINGTON
BAY
CALHOUN
JACKSON
GADSDEN
LIBERTY
GULF
FRANKLIN
WAKULLA
LEON
JE
F
F
E
R
S
O
N
TAYLOR
MADISON
HAMILTON
SUWANNEE
LAFAYETTE
DIXIE GI
L
C
H
R
I
S
T
COLUMBIA
UNION
BAKER
BRA
D
F
O
R
D
ALACHUA
LEVY
MARION
PUTNAM
CLAY
DUVAL
NASSAU
ST
J
O
H
N
S
FLAGLER
VOLUSIA
LAKE
SUMTER
CITRUS
ORANGE
SEMINOLE
OSCEOLA
PASCO
HERNANDO
POLK
HILLSBOROUGH
PI
N
E
L
L
A
S
INDIAN RIVER
BREVARD
ST LUCIE
MARTIN
OKEECHOBEE
HIGHLANDS
HARDEEMANATEE
SARASOTA
DESOTO
GLADES
CHARLOTTE
LEE HENDRY
PALM BEACH
BROWARD
COLLIER
MIAMI-DADEMONROE
ESCAMBIA
COMCAST PERMIT REQUEST FOR LOCATION:
576 COASTAL OAK LN ATLANTIC BEACH FL,
32233
THESE PLANS WERE PREPARED UNDER THE
RESPONSIBLE CHARGE OF COMCAST
COASTAL OAK LANE
REVISIONS
NO.DRAWN BY
LOCATION:
TOTAL JOB LENGTH:
DESCRIPTION:
JOB NO.:SCALE:
PREPARED BY:
SHEET:
DATE
C:
\
U
s
e
r
s
\
l
c
h
i
n
\
D
o
c
u
m
e
n
t
s
\
D
E
C
0
5
-
D
E
C
1
1
\
J
B
8
6
6
2
6
_
D
U
V
A
L
C
O
-
C
A
D
\
J
B
8
6
6
2
6
_
D
U
V
A
L
C
O
-
C
A
D
.
d
w
g
1
2
0
7
,
2
0
2
1
-
2
:
4
0
P
M
L
c
h
i
n
576 COASTAL OAK LN ATLANTIC BEACH
FL, 32233
CATV DIRECTIONAL BORE
PLACEMENT
245' UG
JB866626 NTS 1 OF 5
0 LEC 12/06/2021
ROW21-0069
THE FOLLOWING STANDARD PLANS ARE IN ACCORDANCE
WITH THE FLORIDA DEPARTMENT OF TRANSPORTATION
102-602 & 660 INDEX AND APPLY TO:
576 COASTAL OAK LN ATLANTIC BEACH FL, 32233
NO EXPECTED CONFLICTS
WITH OTHER UTILITIES
REVISIONS
NO.DRAWN BY
LOCATION:
TOTAL JOB LENGTH:
DESCRIPTION:
JOB NO.:SCALE:
PREPARED BY:
SHEET:
DATE
C:
\
U
s
e
r
s
\
l
c
h
i
n
\
D
o
c
u
m
e
n
t
s
\
D
E
C
0
5
-
D
E
C
1
1
\
J
B
8
6
6
2
6
_
D
U
V
A
L
C
O
-
C
A
D
\
J
B
8
6
6
2
6
_
D
U
V
A
L
C
O
-
C
A
D
.
d
w
g
12
0
7
,
2
0
2
1
-
2
:
4
0
P
M
Lc
h
i
n
576 COASTAL OAK LN ATLANTIC BEACH
FL, 32233
CATV DIRECTIONAL BORE
PLACEMENT
245' UG
JB866626 NTS 2 OF 5
0 LEC 12/06/2021
ROAD RIGHT-OF-WAY
SANITARY SEWER
STORM SEWER
LEGEND
CABLE TV SPAN (EXIST)
FENCE
GAS PIPELINE
O/H POWER LINE
U/G POWER LINE
PROPERTY LINE
BOTTOM BANK
TOP BANK
UNKNOWN U/G UTILITY
WATER LINE
COMCAST SPAN ROUTE
COMCAST BORE ROUTE
CABLE TV BORE (EXIST.)
O/H TELEPHONE
U/G TELEPHONE
ROAD CENTERLINE
FIBER OPTIC CABLE
MANHOLE (SANITARY SEWER)
CABLE TV PEDESTAL
MANHOLE (STORM SEWER)
GENERAL NOTES:
ALL PROPOSED UNDERGROUND CATV WILL BE BURIED A MINIMUM OF 36" INCLUDING ROAD BORES AND
DRIVEWAY BORES.
ALL PROPOSED UNDERGROUND CATV ROAD BORES WILL USE CITY APPROVED DIRECTIONAL BORE MACHINE,
AS WELL AS COUNTY APPROVED CONDUIT.
ALL PROPOSED CATV ROAD BORES WILL EXTEND A MINIMUM OF 7' BEYOND THE EDGE OF PAVEMENT.
ALL PROPOSED CATV DRIVEWAY BORES WILL EXTEND A MINIMUM OF 6' BEYOND THE EDGE OF PAVEMENT.
ALL PROPOSED BORES WILL BE IN A (4'X4'X4') PIT AND WILL USE (2)2" HDPE CONDUIT AT 36" DEPTH USING A
5 1/4" DRILL HEAD.
ALL PROPOSED AERIAL CATV WILL BE 0.700" DIAMETER AND WILL BE LASHED TO 0.250" STEEL STRAND CABLE
USING 0.125" STANDARD GALVANIZED LASHING WIRE.
ALL PROPOSED AERIAL CATV CROSSING ROADWAYS WILL HAVE A MINIMUM MID-SPAN HEIGHT OF 18'-0".
ALL PROPOSED AERIAL CATV CROSSING DRIVEWAYS WILL HAVE A MINIMUM MID-SPAN HEIGHT OF 16'-0".
LOCATES WILL BE REQUIRED IN ALL PROPOSED UNDERGROUND AREAS AT LEAST 48 HRS PRIOR TO
CONSTRUCTION.
NOTIFICATIONS TO ALL UTILITIES INVOLVED WILL BE MADE PRIOR TO CONSTRUCTION.
ALL DISTRIBUTED AREA WITHIN THE RIGHT OF WAY WILL BE RESTORED TO ORIGINAL OR BETTER CONDITION
BY GRADING AND RE-SODDING. SOD ALL AREAS DISTURBED BY CONSTRUCTION WITH BERMUDA SOD. "ALL
CRACKED SIDEWALKS ARE TO BE REPLACED FROM JOINT TO JOINT WITHIN 7 DAYS OF WORK COMPLETION."
WORK OPERATIONS ARE TO BE MINDFUL NOT TO DAMAGE THE PAVER SIDEWALK WHEN POSITIONING
EQUIPMENT. ANY DAMAGE INCLUDING TRACK MARKS WILL BE REPAIRED OR REPLACED BY THE CONTRACTOR.
CONSTRUCTION NOTES:
IN ORDER TO REDUCE THE DISRUPTION AND COST OF UTILITY DAMAGES OCCURRING IN THE RIGHT-OF-WAY
AND EASEMENTS. THE PERMITTEE SHALL PREVENT DAMAGES TO EXISTING UTILITIES CAUSED BY THE WORK
THROUGH FIELD VERIFICATION OF THE LOCATION OF THE EXISTING UTILITIES IN CASE OF OPEN EXCAVATION.
VERIFICATION MAY BE PERFORMED DURING THE PERMITTEES WORK. IN THE CASE OF DIRECTIONAL DRILLING,
VERIFICATION SHALL TAKE PLACE PRIOR TO MOBILIZATION OF THE DRILLING EQUIPMENT.
THE PERMITTEE SHALL VERIFY THE LOCATION OF THE EXISTING UTILITIES AS NEEDED TO AVOID CONTACT
WITH DETECTION EQUIPMENT OR OTHER ACCEPTABLE MEANS, SUCH METHODS MAY INCLUDE BUT SHALL NOT
BE LIMITED TO-"SOFT DIG"-EQUIPMENT AND GROUND PENETRATION RADAR (GPR). THE EXCAVATOR SHALL BE
HELD LIABLE FOR DAMAGES CAUSED TO CITY'S/COUNTY'S/STATE INFRASTRUCTURE AND THE EXISTING
FACILITIES OF THE OTHER UTILITY COMPANIES.
NO REAMER USED
SS
MH
EDGE OF PAVEMENT
CABLE TV RISER
UTILITY POLE
D/W
D/WD/WD/W
D/W
MH COASTAL OAK LANE
C
O
A
S
T
A
L
O
A
K
L
A
N
E
588 582
576
594
600
583
577
0
589
50'22'
12'
12'
2'
2'
R/W
C&G
EOP
R/W
EOP
C&G
R/W
C&G
EOP
R/W
EOP
C&G
R/
W
C
&
G
E
O
P
R/
W
E
O
P
C
&
G
SW
SW
S
W
11'11'
115'
0+00
BEGIN U/G,
EXISTING
CATV PED
2+45
END U/G,
EXISTING
CATV PED
1+30
EXISTING
CATV PED
50'
22'
12'
12'
2'
2'
2'
2'
22'
50'
12'
12'
PROPOSED BORE PLACEMENT
FOR 245' ALONG COASTAL OAK
LANE AT MIN DEPTH OF 36"
USING 2" 13.5 SDR ROLL PIPE
WITH 0.700" COAXIAL CABLE
INSIDE
4' SW
4' SW
4' SW
4' SW
130'
EXISTING
ELEC PED EXISTING WATER
METER VAULT
EXISTING WATER METER VAULT
EXISTING CATV PED
WATER METER VAULT
EXISTING TEL PED
WATER METER VAULT
EXISTING TEL PED
EXISTING WATER VAULT
360' ± TO MARITIME OAK DR
300' ± TO ATL
A
N
T
I
C
B
E
A
C
H
D
R
C&
G
R/
W
EO
P
C/L
COASTAL OAK LANE
TYP ALLOCATION
-36" MIN
-48" MIN
50'
12'22'12'
R/
W
2'
C
&
G
CA
T
V
C&
G
11'
TE
L
E
9'
WA
T
E
R
EL
E
C
7'
5'
EO
P
2'
C
&
G
SA
N
4' S/W 4' S/WC/L
GA
S
3'
NO EXPECTED CONFLICTS
WITH OTHER UTILITIES
REVISIONS
NO.DRAWN BY
LOCATION:
TOTAL JOB LENGTH:
DESCRIPTION:
JOB NO.:SCALE:
PREPARED BY:
SHEET:
DATE
C:
\
U
s
e
r
s
\
l
c
h
i
n
\
D
o
c
u
m
e
n
t
s
\
D
E
C
0
5
-
D
E
C
1
1
\
J
B
8
6
6
2
6
_
D
U
V
A
L
C
O
-
C
A
D
\
J
B
8
6
6
2
6
_
D
U
V
A
L
C
O
-
C
A
D
.
d
w
g
12
0
7
,
2
0
2
1
-
2
:
4
0
P
M
Lc
h
i
n
576 COASTAL OAK LN ATLANTIC BEACH
FL, 32233
CATV DIRECTIONAL BORE
PLACEMENT
245' UG
JB866626 NTS 3 OF 5
0 LEC 12/06/2021
C:
\
U
s
e
r
s
\
l
c
h
i
n
\
D
o
c
u
m
e
n
t
s
\
D
E
C
0
5
-
D
E
C
1
1
\
J
B
8
6
6
2
6
_
D
U
V
A
L
C
O
-
C
A
D
\
J
B
8
6
6
2
6
_
D
U
V
A
L
C
O
-
C
A
D
.
d
w
g
12
0
7
,
2
0
2
1
-
2
:
4
1
P
M
Lc
h
i
n
SHEET
4 OF 5
C:
\
U
s
e
r
s
\
l
c
h
i
n
\
D
o
c
u
m
e
n
t
s
\
D
E
C
0
5
-
D
E
C
1
1
\
J
B
8
6
6
2
6
_
D
U
V
A
L
C
O
-
C
A
D
\
J
B
8
6
6
2
6
_
D
U
V
A
L
C
O
-
C
A
D
.
d
w
g
12
0
7
,
2
0
2
1
-
2
:
4
1
P
M
Lc
h
i
n
SHEET
5 OF 5