Loading...
576 COASTAL OAK LN ROW21-0069 Comcast CableOWNER:ADDRESS:CITY:STATE:ZIP: HICKS ANTHONY R 2403 SARAGOSSA AVE JACKSONVILLE FL 32217 COMPANY:ADDRESS:CITY:STATE:ZIP: SOUTHEAST UTILITIES 1 ENERGY PL PENSACOLA FL 32520 TYPE OF CONSTRUCTION: REAL ESTATE NUMBER:ZONING:BUILDING USE GROUP:SUBDIVISION: 169505 2035 ATLANTIC BEACH COUNTRY CLUB UNIT 02 JOB ADDRESS:PERMIT TYPE:DESCRIPTION: VALUE OF WORK: 576 COASTAL OAK LN RIGHT OF WAY COMMERCIAL RIGHT OF WAY COMCAST - CABLE REPLACEMENT $0.00 LIST OF CONDITIONS Roll off container company must be on City approved list . Container cannot be placed on City right-of-way. 1 PUBLIC WORKS ON SITE RUNOFF INFORMATIONAL Notes: All runoff must remain on-site during construction. 2 PUBLIC WORKS ROLL OFF CONTAINER INFORMATIONAL Notes: Roll off container company must be on City approved list. Approved list can be obtained at the Building Department at City Hall. Roll off container cannot be placed on City right-of-way. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION. ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES . ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY. 1 of 2Issued Date: 1/19/2022 PERMIT NUMBER ROW21-0069 ISSUED: 1/19/2022 EXPIRES: 4/19/2022 RIGHT OF WAY PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 FEES DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT TOTAL: 3 PUBLIC WORKS RIGHT OF WAY RESTORATION INFORMATIONAL Notes: Full right-of-way restoration, including sod, is required. 4 PUBLIC WORKS INFRASTRUCTURE INFORMATIONAL Notes: Any damage done to infrastructure must be repaired by Contractor. 5 PUBLIC WORKS AS-BUILT INFORMATIONAL Notes: Contractor must submit As-Built plans to City within 30 days after completion of project. 6 PUBLIC WORKS DEBRIS INFORMATIONAL Notes: Roadway must be kept free of debris, mud, dirt, etc. during and after project by Contractor. All holes that have been dug and any property that has been disturbed must have barriers and flags placed during project by Contractor. 7 PUBLIC UTILITIES UNDERGROUND WATER SEWER UTILITIES INFORMATIONAL Notes: 2 of 2Issued Date: 1/19/2022 PERMIT NUMBER ROW21-0069 ISSUED: 1/19/2022 EXPIRES: 4/19/2022 RIGHT OF WAY PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 R O W 2 1 - 0 0 6 9 NO EXPECTED CONFLICTS WITH OTHER UTILITIES VICINITY MAP: 576 COASTAL OAK LN ATLANTIC BEACH FL, 32233 DUVAL COUNTY SANTA ROSA OKALOOSA WALTON HOLMES WASHINGTON BAY CALHOUN JACKSON GADSDEN LIBERTY GULF FRANKLIN WAKULLA LEON JE F F E R S O N TAYLOR MADISON HAMILTON SUWANNEE LAFAYETTE DIXIE GI L C H R I S T COLUMBIA UNION BAKER BRA D F O R D ALACHUA LEVY MARION PUTNAM CLAY DUVAL NASSAU ST J O H N S FLAGLER VOLUSIA LAKE SUMTER CITRUS ORANGE SEMINOLE OSCEOLA PASCO HERNANDO POLK HILLSBOROUGH PI N E L L A S INDIAN RIVER BREVARD ST LUCIE MARTIN OKEECHOBEE HIGHLANDS HARDEEMANATEE SARASOTA DESOTO GLADES CHARLOTTE LEE HENDRY PALM BEACH BROWARD COLLIER MIAMI-DADEMONROE ESCAMBIA COMCAST PERMIT REQUEST FOR LOCATION: 576 COASTAL OAK LN ATLANTIC BEACH FL, 32233 THESE PLANS WERE PREPARED UNDER THE RESPONSIBLE CHARGE OF COMCAST COASTAL OAK LANE REVISIONS NO.DRAWN BY LOCATION: TOTAL JOB LENGTH: DESCRIPTION: JOB NO.:SCALE: PREPARED BY: SHEET: DATE C: \ U s e r s \ l c h i n \ D o c u m e n t s \ D E C 0 5 - D E C 1 1 \ J B 8 6 6 2 6 _ D U V A L C O - C A D \ J B 8 6 6 2 6 _ D U V A L C O - C A D . d w g 1 2 0 7 , 2 0 2 1 - 2 : 4 0 P M L c h i n 576 COASTAL OAK LN ATLANTIC BEACH FL, 32233 CATV DIRECTIONAL BORE PLACEMENT 245' UG JB866626 NTS 1 OF 5 0 LEC 12/06/2021 ROW21-0069 THE FOLLOWING STANDARD PLANS ARE IN ACCORDANCE WITH THE FLORIDA DEPARTMENT OF TRANSPORTATION 102-602 & 660 INDEX AND APPLY TO: 576 COASTAL OAK LN ATLANTIC BEACH FL, 32233 NO EXPECTED CONFLICTS WITH OTHER UTILITIES REVISIONS NO.DRAWN BY LOCATION: TOTAL JOB LENGTH: DESCRIPTION: JOB NO.:SCALE: PREPARED BY: SHEET: DATE C: \ U s e r s \ l c h i n \ D o c u m e n t s \ D E C 0 5 - D E C 1 1 \ J B 8 6 6 2 6 _ D U V A L C O - C A D \ J B 8 6 6 2 6 _ D U V A L C O - C A D . d w g 12 0 7 , 2 0 2 1 - 2 : 4 0 P M Lc h i n 576 COASTAL OAK LN ATLANTIC BEACH FL, 32233 CATV DIRECTIONAL BORE PLACEMENT 245' UG JB866626 NTS 2 OF 5 0 LEC 12/06/2021 ROAD RIGHT-OF-WAY SANITARY SEWER STORM SEWER LEGEND CABLE TV SPAN (EXIST) FENCE GAS PIPELINE O/H POWER LINE U/G POWER LINE PROPERTY LINE BOTTOM BANK TOP BANK UNKNOWN U/G UTILITY WATER LINE COMCAST SPAN ROUTE COMCAST BORE ROUTE CABLE TV BORE (EXIST.) O/H TELEPHONE U/G TELEPHONE ROAD CENTERLINE FIBER OPTIC CABLE MANHOLE (SANITARY SEWER) CABLE TV PEDESTAL MANHOLE (STORM SEWER) GENERAL NOTES: ALL PROPOSED UNDERGROUND CATV WILL BE BURIED A MINIMUM OF 36" INCLUDING ROAD BORES AND DRIVEWAY BORES. ALL PROPOSED UNDERGROUND CATV ROAD BORES WILL USE CITY APPROVED DIRECTIONAL BORE MACHINE, AS WELL AS COUNTY APPROVED CONDUIT. ALL PROPOSED CATV ROAD BORES WILL EXTEND A MINIMUM OF 7' BEYOND THE EDGE OF PAVEMENT. ALL PROPOSED CATV DRIVEWAY BORES WILL EXTEND A MINIMUM OF 6' BEYOND THE EDGE OF PAVEMENT. ALL PROPOSED BORES WILL BE IN A (4'X4'X4') PIT AND WILL USE (2)2" HDPE CONDUIT AT 36" DEPTH USING A 5 1/4" DRILL HEAD. ALL PROPOSED AERIAL CATV WILL BE 0.700" DIAMETER AND WILL BE LASHED TO 0.250" STEEL STRAND CABLE USING 0.125" STANDARD GALVANIZED LASHING WIRE. ALL PROPOSED AERIAL CATV CROSSING ROADWAYS WILL HAVE A MINIMUM MID-SPAN HEIGHT OF 18'-0". ALL PROPOSED AERIAL CATV CROSSING DRIVEWAYS WILL HAVE A MINIMUM MID-SPAN HEIGHT OF 16'-0". LOCATES WILL BE REQUIRED IN ALL PROPOSED UNDERGROUND AREAS AT LEAST 48 HRS PRIOR TO CONSTRUCTION. NOTIFICATIONS TO ALL UTILITIES INVOLVED WILL BE MADE PRIOR TO CONSTRUCTION. ALL DISTRIBUTED AREA WITHIN THE RIGHT OF WAY WILL BE RESTORED TO ORIGINAL OR BETTER CONDITION BY GRADING AND RE-SODDING. SOD ALL AREAS DISTURBED BY CONSTRUCTION WITH BERMUDA SOD. "ALL CRACKED SIDEWALKS ARE TO BE REPLACED FROM JOINT TO JOINT WITHIN 7 DAYS OF WORK COMPLETION." WORK OPERATIONS ARE TO BE MINDFUL NOT TO DAMAGE THE PAVER SIDEWALK WHEN POSITIONING EQUIPMENT. ANY DAMAGE INCLUDING TRACK MARKS WILL BE REPAIRED OR REPLACED BY THE CONTRACTOR. CONSTRUCTION NOTES: IN ORDER TO REDUCE THE DISRUPTION AND COST OF UTILITY DAMAGES OCCURRING IN THE RIGHT-OF-WAY AND EASEMENTS. THE PERMITTEE SHALL PREVENT DAMAGES TO EXISTING UTILITIES CAUSED BY THE WORK THROUGH FIELD VERIFICATION OF THE LOCATION OF THE EXISTING UTILITIES IN CASE OF OPEN EXCAVATION. VERIFICATION MAY BE PERFORMED DURING THE PERMITTEES WORK. IN THE CASE OF DIRECTIONAL DRILLING, VERIFICATION SHALL TAKE PLACE PRIOR TO MOBILIZATION OF THE DRILLING EQUIPMENT. THE PERMITTEE SHALL VERIFY THE LOCATION OF THE EXISTING UTILITIES AS NEEDED TO AVOID CONTACT WITH DETECTION EQUIPMENT OR OTHER ACCEPTABLE MEANS, SUCH METHODS MAY INCLUDE BUT SHALL NOT BE LIMITED TO-"SOFT DIG"-EQUIPMENT AND GROUND PENETRATION RADAR (GPR). THE EXCAVATOR SHALL BE HELD LIABLE FOR DAMAGES CAUSED TO CITY'S/COUNTY'S/STATE INFRASTRUCTURE AND THE EXISTING FACILITIES OF THE OTHER UTILITY COMPANIES. NO REAMER USED SS MH EDGE OF PAVEMENT CABLE TV RISER UTILITY POLE D/W D/WD/WD/W D/W MH COASTAL OAK LANE C O A S T A L O A K L A N E 588 582 576 594 600 583 577 0 589 50'22' 12' 12' 2' 2' R/W C&G EOP R/W EOP C&G R/W C&G EOP R/W EOP C&G R/ W C & G E O P R/ W E O P C & G SW SW S W 11'11' 115' 0+00 BEGIN U/G, EXISTING CATV PED 2+45 END U/G, EXISTING CATV PED 1+30 EXISTING CATV PED 50' 22' 12' 12' 2' 2' 2' 2' 22' 50' 12' 12' PROPOSED BORE PLACEMENT FOR 245' ALONG COASTAL OAK LANE AT MIN DEPTH OF 36" USING 2" 13.5 SDR ROLL PIPE WITH 0.700" COAXIAL CABLE INSIDE 4' SW 4' SW 4' SW 4' SW 130' EXISTING ELEC PED EXISTING WATER METER VAULT EXISTING WATER METER VAULT EXISTING CATV PED WATER METER VAULT EXISTING TEL PED WATER METER VAULT EXISTING TEL PED EXISTING WATER VAULT 360' ± TO MARITIME OAK DR 300' ± TO ATL A N T I C B E A C H D R C& G R/ W EO P C/L COASTAL OAK LANE TYP ALLOCATION -36" MIN -48" MIN 50' 12'22'12' R/ W 2' C & G CA T V C& G 11' TE L E 9' WA T E R EL E C 7' 5' EO P 2' C & G SA N 4' S/W 4' S/WC/L GA S 3' NO EXPECTED CONFLICTS WITH OTHER UTILITIES REVISIONS NO.DRAWN BY LOCATION: TOTAL JOB LENGTH: DESCRIPTION: JOB NO.:SCALE: PREPARED BY: SHEET: DATE C: \ U s e r s \ l c h i n \ D o c u m e n t s \ D E C 0 5 - D E C 1 1 \ J B 8 6 6 2 6 _ D U V A L C O - C A D \ J B 8 6 6 2 6 _ D U V A L C O - C A D . d w g 12 0 7 , 2 0 2 1 - 2 : 4 0 P M Lc h i n 576 COASTAL OAK LN ATLANTIC BEACH FL, 32233 CATV DIRECTIONAL BORE PLACEMENT 245' UG JB866626 NTS 3 OF 5 0 LEC 12/06/2021 C: \ U s e r s \ l c h i n \ D o c u m e n t s \ D E C 0 5 - D E C 1 1 \ J B 8 6 6 2 6 _ D U V A L C O - C A D \ J B 8 6 6 2 6 _ D U V A L C O - C A D . d w g 12 0 7 , 2 0 2 1 - 2 : 4 1 P M Lc h i n SHEET 4 OF 5 C: \ U s e r s \ l c h i n \ D o c u m e n t s \ D E C 0 5 - D E C 1 1 \ J B 8 6 6 2 6 _ D U V A L C O - C A D \ J B 8 6 6 2 6 _ D U V A L C O - C A D . d w g 12 0 7 , 2 0 2 1 - 2 : 4 1 P M Lc h i n SHEET 5 OF 5