Loading...
617 PARADISE CT POOL22-0001 PoolOWNER:ADDRESS:CITY:STATE:ZIP: LAZARUS GRAHAM A 617 PARADISE CT ATLANTIC BEACH FL 32233-6946 COMPANY:ADDRESS:CITY:STATE:ZIP: POOLS BY JOHN CLARKSON, INC.600 ST JOHNS BLUFF RD JACKSONVILLE FL 32225 TYPE OF CONSTRUCTION: REAL ESTATE NUMBER:ZONING:BUILDING USE GROUP:SUBDIVISION: 172386 2045 PARADISE COVE JOB ADDRESS:PERMIT TYPE:DESCRIPTION: VALUE OF WORK: 617 PARADISE CT SWIMMING POOL SWIMMING POOL RESIDENTIAL SWIMMING POOL $39000.00 LIST OF CONDITIONS Roll off container company must be on City approved list . Container cannot be placed on City right-of-way. 1 PUBLIC WORKS EROSION CONTROL INSTALLATION INFORMATIONAL Notes: Full erosion control measures must be installed and approved prior to beginning any earth disturbing activities. Contact the Inspection Line (904-247- 5814) to request an Erosion and Sediment Control Inspection prior to start of construction. 2 PUBLIC WORKS ON SITE RUNOFF INFORMATIONAL Notes: All runoff must remain on-site during construction. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION. ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES . ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY. 1 of 2Issued Date: 1/25/2022 PERMIT NUMBER POOL22-0001 ISSUED: 1/25/2022 EXPIRES: 7/24/2022 SWIMMING POOL PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 FEES DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT BUILDING PERMIT 455-0000-322-1000 0 $250.00 BUILDING PLAN CHECK 455-0000-322-1001 0 $125.00 PW REVIEW RESIDENTIAL BLDG 001-0000-329-1004 0 $100.00 STATE DBPR SURCHARGE 455-0000-208-0700 0 $5.63 STATE DCA SURCHARGE 455-0000-208-0600 0 $3.75 ZONING REVIEW SINGLE AND TWO FAMILY USES 001-0000-329-1003 0 $100.00 TOTAL: $584.38 3 PUBLIC WORKS POOL WELLPOINT INFORMATIONAL Notes: Pool Wellpoint (if used) must discharge into vegetated area 10 foot minimum from street or drainage feature (swale, structure or lagoon). 4 PUBLIC WORKS ROLL OFF CONTAINER INFORMATIONAL Notes: Roll off container company must be on City approved list. Approved list can be obtained at the Building Department at City Hall. Roll off container cannot be placed on City right-of-way. 5 PUBLIC WORKS RIGHT OF WAY RESTORATION INFORMATIONAL Notes: Full right-of-way restoration, including sod, is required. 6 PUBLIC WORKS DECKING REMOVED INFORMATIONAL Notes: All old decking and debris must be removed from job site by Contractor. 7 PUBLIC WORKS INFRASTRUCTURE INFORMATIONAL Notes: Any damage done to infrastructure must be repaired by Contractor. 2 of 2Issued Date: 1/25/2022 PERMIT NUMBER POOL22-0001 ISSUED: 1/25/2022 EXPIRES: 7/24/2022 SWIMMING POOL PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 Final Plumbing Final Electrical Final HVAC CC Final Final Building* Swimming Pool Steel Swimming Pool Safety Electrical Grounding & Bonding Swimming Pool Final (Bldg) Swimming Pool Final (PW) Formed Columns/ Beams* Masonry Cell Fill Structural Steel* OTHER: OTHER: OTHER: OTHER: OTHER: Power Pole Silt Fence Piers/ Stem Walls Underground Plumbing Underground Electric Foundation/ Footing Slab** Retaining Wall Footing Driveway Sewer (Building Dept) Sewer Tap (Utilities Dept) Rough Electric* Rough Plumbing/ Top Out* Rough Mechanical* House Wrap Wall Sheathing Roof Sheathing Tie-down Framing Connections Rough Framing Roofing In Progress Window/Door In-Progress Insulation Ceiling Insulation Wall Exterior Lath Stucco Scratch Coat Exterior Siding In-Progress Brick Flashing & Ties Early Power Gas Rough Gas Final* * When all rough electric, plumbing, mechanical are complete but before any work is covered up. * When all gas piping is complete and wallboard is installed but before gas is attached to any appliance. All outlets must be capped and pipe pressurized at a minimum of 15 lbs. * For new living space: When all construction work including electrical, plumbing, mechanical, exterior finish, grading, required paving and landscaping is complete and the building is ready for occupancy, but before being occupied Additional inspections may apply to your project if your project contains these elements: INSPECTIONS REQUIRED FOR BUILDING PERMITS To verify compliance with building codes, inspections of the work authorized are required at various points of the construction. The following inspections are typically required for residential projects: Date: Initial: Date: Initial: _____________________________________________________ Permit Type ____________________________________________________ Permit No. __________________________________________________________ Job Address ____________________________________________________ Contractor POST THIS CARD WITH PERMITS AND PERMIT DOCUMENTATION IN FRONT OF BUILDING Construction Hours per City Code: 7am—7pm Weekdays; 9am—7pm Weekends Building Department Public Works/Utilities Fire Department Phone: 904-247-5826 Phone: 904-247-5834 Phone: 904-630-4789 Fax: 904-247-5845 Fax: 904-247-5843 Fax: 904-630-4203 * When forms and reinforcing steel, anchor bolts, sleeves and inserts, and all electrical, plumbing and mechanical work is in place, but before concrete is poured. * When all structural steel members are in place and all connections are complete, but before such work is covered or concealed. ** FORM BOARD ELEVATION CERTIFICATE MUST BE ON-SITE FOR SLAB INSPECTION POOL22-0001 POOL22-0001 POOL22-0001 SWIM-OUT OR LADDER REQUIRED (GR/#8 CU) WHERE DEPTH OVER 5' DEEP (SEE NOTES) ENTRY REQUIRED (SEE NOTES) RAIL OPTIONAL FLOW THRU SPA NO SKIMMER 1' - 6 " NO LIMITATIONS TO SHAPE EXCEPT FOR DIVING OPTIONAL 12V LIGHT W/TRANS. 3 4" BRASS OR PVC (SEE NOTES) SKIMMER TYPICAL GR. FOR # 3 REBAR, 2' OUT WITH # 8 CU TO PUMP OPTIONAL DECK W/ 1 1 2" PITCH IN 10' GENERAL POOL PLAN N.T.S. A A A S-1 2'-9" Min. EXCEPT FOR SLOPING ENTRIES. 4'-0" Max. WATER LINE 3 Max. 7 Max. 11.0° Max. 8" Max. Radius 1 1 4 ' - 9 " 4 ' - 0 " 8' Min. TO SLOPE CHANGE POOL SECTION DETAIL N.T.S. E S-1 SKIMMER REQUIRED FOR SPA WITH INDEPENDENT FILTRATION SYSTEM MAIN DRAIN REQUIRE (TAMPER PROOF/SEE NOTES) LIGHTING & BONDING SAME AS POOL NO LIMITATIONS ON SHAPE GENERAL SPA PLAN N.T.S. CIRCULATION LINE RAIL OPTIONAL STEPS OPTIONAL B S-1 SB836, 6-20-07 FOR BONDING AND GROUNDING SYSTEMS FOR SWIMMING POOLS, THE USE OF AN UNDERGROUND BONDING CONDUCTOR MADE OF #8 AWG. BARE SOLID COPPER WIRE BURIED TO A MINIMUM DEPTH OF 4 INCHES TO 6 INCHES BELOW SUBGRADE, AND 18 TO 24 INCHES FROM INSIDE WALL OF A SWIMMING POOL OR SPA, IS DEEMED A PERMISSIBLE ALTERNATIVE OR EQUIVALENT TO COMPLIANCE WITH s. 680.26(c) OF THE NATIONAL ELECTRICAL CODE. POOL RESIDENCE CLEANER LINE EQUIPMENT LOCATION 3 ' - 0 " * MAIN DRAINS AS OF 12-19-08 ANSI/ASME A112.19.8-2007 MIN. GRATE OPEN AREA = FLOW/17.8 FOR VELOCITY 6'/SEC PIPE SIZING CHART (MAXIMUM) SUCTION PRESSURE 35 GPM 60 90 135 235 65 GPM 105 147 230 396 PIPE 1 1 2" 2" 3" 4" 2 1 2 MAIN SUCTION PIPE SIZE _____ SKIMMER SUCTION PIPE SIZE ______ CLEANER/VAC PIPE SIZE ______ RETURN PIPE SIZE ______ ELECTRICAL REQUIREMENTS: FLORIDA BUILDING CODE R4501 -WIRING AND BONDING AND ALL ELECTRICAL TO COMPLY WITH CHAPTER 27, FLORIDA BUILDING CODE 7TH EDITION-RESIDENTIAL AND NEC 2017. -NO OUTLET OR OVERHEAD POWER WITHIN 10' IF WITHIN 15' PROTECT BY GFI, TRANSFORMER MIN. 10' FROM POOL, 8" ABOVE WATER, J BOX 4' FROM POOL, BRASS TO J BOX OR TRANSFORMER WHICH EVER IS FIRST EXCEPT WHERE PVC IS APPROVED. THE POOL CONTRACTOR IS RESPONSIBLE FOR FURNISHING ALL DETAIL DESIGN REQUIREMENTS FOR EACH INDIVIDUAL POOL IN ACCORDANCE WITH THE FLORIDA BUILDING CODE, AND ALL CONSTRUCTION SHALL MEET ALL APPLICABLE CODES INCLUDING PLUMBING, ELECTRICAL AND GAS. PIPING SHALL BE SCH. 40 PVC, NSFpw, MAX. PRESSURE VELOCITY 10 FPS, SUCTION 6 FPS. THE POOL PLAN SHALL SHOW THE DESIGN PLUMBING AS PER THE SAMPLE WITH THE INFORMATION REQUIRED SHOWN. MAIN DRAIN PLUMBING SHALL BE TWO DRAINS SEPARATED BY 3' WITH APPROVED ANSI/ASME A112.19.8.2009 COVERS. AS AN ALTERNATE THE APPROVED DRAINS MAY BE PLACED ON DIFFERENT PLANES. THE TWO DRAINS SHALL HAVE A COMMON SUCTION LINE. SUCTION GRATES MAY BE USED IF APPROVED AT A MAXIMUM OF 1 1 2 FPS AND THE SUCTION PIPING IS RECESSED FROM THE GRATE THE DISTANCE EQUAL TO THE SUCTION PIPE SIZE. SKIMMERS DO NOT REQUIRE PROTECTION AND MUST BE DESIGNED FOR A MINIMUM 25 gpm. THE FOLLOWING SHALL BE LABELED WITH LABEL MARKER TAPE AT THE FILTER LOCATION: PIPES, VALVES, PUMP(S) OFF SWITCH. GENERAL DESIGN REQUIREMENTS -DESIGN, CONSTRUCTION AND WORKMANSHIP SHALL BE IN CONFORMITY WITH THE REQUIREMENTS OF APSP/ICC 3, APSP/ICC 4, APSP/ICC 5, AND APSP/ICC 6 AND APSP/ICC 7 BASED ON THE POOL TYPE. -SEE NSPI FOR DIVING WATER ENVELOPES. -SLIDES SHALL MEET THE MANUFACTURE'S INSTALLATION REQUIREMENTS. -ALL POOLS WHETHER PUBLIC OR PRIVATE SHALL BE PROVIDED WITH A LADDER OR STEPS IN THE SHALLOW END WHERE THE WATER DEPTH EXCEEDS 24 INCHES (610 MM). IN PRIVATE POOLS WHERE WATER DEPTH EXCEEDS 5 FEET (1524 MM) THERE SHALL BE LADDERS, STAIRS OR UNDERWATER BENCHES/ SWIM-OUTS IN THE DEEP END. WHERE MANUFACTURED DIVING EQUIPMENT IS TO BE USED, BENCHES OR SWIM-OUTS SHALL BE RECESSED OR LOCATED IN A CORNER. -CIRCULATION SYSTEMS, COMPONENTS AND EQUIPMENT SHALL COMPLY WITH NSF 50. -THE MAXIMUM TURNOVER RATE IS 12 HOURS. -FILTERS SHALL HAVE AN AIR RELEASE AND PRESSURE GAGE. -PUMPS 3 HP AND LESS SHALL MEET ANSI/UL1081 CORROSION RESISTANT WITH STRAINER AND MEET THE REQUIRED FLOW. -SURFACE SKIMMERS SHALL MEET NSF 50 AND THERE SHALL BE ONE FOR EVERY 800 SQUARE FEET OF SURFACE AREA. -APPROVED MANUFACUTRED INLET FITTNGS FOR THE RETURN OF RECIRCULATED POOL WATER SHALL BE PROVIDED ON THE BASIS OF AT LEAST ONE PER 300 SQUARE FEET (28 m2) OF SURFACE AREA. SUCH INLET FITTINGS SHALL BE DESIGNED AND CONSTRUCTED TO INSURE AN ADEQUATE SEAL TO THE POOL STRUCTURE AND SHALL INCORPORATE A CONVENIENT MEANS OF SEALING FOR PRESSURE TESTING OF THE POOL CIRCULATION PIPING. WHEN MORE THAN ONE INLET IS REQUIRED, THE SHORTEST DISTANCE BETWEEN ANY TWO REQUIRED INLETS SHALL BE AT LEAST 10 FEET (3048 MM). -HEATER SHALL MEET ANSI-Z21.56 OR UL 1261 OR UL 559. -DISINFECTANT EQUIPMENT SHALL COMPLY WITH NSF 50. -PRESSURE TEST PIPING AT 35 PSI FOR 15 MINUTES OR MEET LOCAL CODE IF GREATER. -RESIDENTIAL SWIMMING BARRIER REQUIREMENTS TO MEET SECTONS 4501.17 -WASTE DISPOSAL TO COMPLY WITH SECTION 454.2.10 R403.10 (MANDATORY) POOLS & PERMANENT SPA ENERGY CONSUMPTION - THE ENERGY CONSUMPTION OF POOLS AND PERMANENT SPAS SHALL BE IN ACCORDANCE WITH SECTIONS R403.10.1 THROUGH R403.10.5. SPECIAL SPA REQUIREMENTS: -MAXIMUM WATER DEPTH 4', MAXIMUM SEAT DEPTH 28", MAX. -FLOOR SLOPE 1:12 -STEPS: MIN. TREAD 10" X 12", 7" MIN. RISER, 12" MAX. RISER EXCEPT THE BOTTOM STEP MAY BE 14" IF IT IS THE SEAT. INTERMEDIATE TREADS AND RISERS TO BE UNIFORM. IF THE SPA IS OPERATED INTERMITTENTLY IT SHALL HAVE A ONE HOUR TURNOVER, IF CONTINUOUS A SIX HOUR TURNOVER. -MAXIMUM TEMPERATURE 104 DEGREES. -MEET ANSI/NSPI ARTICLE XVII, SAFETY INSTRUCTION/SAFETY SIGNS. -PRESSURE TEST PIPING AT 35 PSI FOR 15 MINUTES OR MEET LOCAL CODE IF GREATER. IT HAS BEEN CERTIFIED THAT THESE DESIGN REQUIREMENTS ARE IN COMPLIANCE WITH THE FLORIDA BUILDING CODE 7TH EDITION, R4501,ANSI/APSP/ICC 3, ANSI/APSP/ICC 4, ANSI/APSP/ICC 5, AND ANSI/APSP/ICC 6 AND ANSI/APSP/ICC 7, ANSI/APSP/ICC 14, ANSI/APSP/ICC 15. STEEL AT SKIMMER BEAM DETAIL N.T.S. BEAM NOTCH-OUT OR CUT-OUT FOR SKIMMER BEND REBAR AROUND SKIMMER NOTCH-OUT FOR CONTINUOUS BEAM (2) #3 BARS (2" MIN. COVERAGE) POOL SHELL STEEL #3 BAR @ 12" O.C.E.W. SKIMMER 3" MIN. STEEL COVERAGE D S-1 PAVERS OR 4" DECK 3,000 psi (Min.) CONC. W/FIBER MESH FOOTING OPTIONAL 1 2 " 12" 12" X 12" FOOTING W/(2) #5 BARS DECK FINISH PER CONTRACT (NON-SLIP) 6" POOL/SPA CROSS SECTION A-A' N.T.S. 6" Min. WALL & FLOOR THICKNESS. 3,000 psi (MIN.) CONC. #3 BARS ON 12" CENTERS EITHER WAY, TIE ALT. INTERSECTIONS 15" MIN. OVERLAP. 2" MIN.COVERAGE ON STEEL W/CONC. TO ASTM A15. A16. ASTM A30-5 Structural subject to suitable soil conditions. COPING- CONFIRM WITH OWNER 8 " 4 " BEAM & "7" BAR OPTIONAL PROVIDE EXPANSION JOINT MATERIAL FOR POURED DECK CONDITION COPING & TILE- CONFIRM WITH OWNER POOL/SPA COMMON WALL (2 ROWS) #3 REBAR @ 6" O.C.E.W., STAGGERED POOL FINISH PER CONTRACT FINISH 3 8" MARCITE OR EXPOSED AGGREGATE 10"-12" WATERLINE POOL FINISH PER CONTRACT FINISH 3 8" MARCITE OR EXPOSED AGGREGATE 8" 6 " 6 " POOL SPA DECK FINISH PER CONTRACT (NON-SLIP) WATERLINE 12" 6" 8 " 4 " 8" POOL C S-1 St a n d a r d R e s i d e n t i a l P o o l an d / o r S p a D e s i g n Gr a h a m L a z a r u s 61 7 P a r a d i s e C o u r t At l a n t i c B e a c h , F L 3 2 2 3 3 CE R T I F I C A T E O F A U T H O R I Z A T I O N 2 7 9 3 4 G. B . C O l l I N s E N G I N E E R I N G P . A . AQ U A T I C E N G I N E E R I N G C O N S U L T A N T S 30 0 A L T E R N A T E 1 9 N O R T H , S U I T E A PA L M H A R B O R , F L O R I D A 3 4 6 8 3 gb _ c o l l i n s @ v e r i z o n . n e t (7 2 7 ) - 4 4 2 - 8 4 4 3 COMPLIES WITH FLORIDA BUILDING CODE, 7TH EDITION (2020) SA M U E L A . L I B E R A T O R E , P . E . # 5 5 7 4 0 no v e m b e r 3 0 , 2 0 2 1 S-1