Loading...
89 Nicole Ln ROOF21-0097 PLI-DECK WATERPROOFINGOWNER:ADDRESS:CITY:STATE:ZIP: WILLIS JOHN R III 89 NICOLE LN ATLANTIC BEACH FL 32233-5979 COMPANY:ADDRESS:CITY:STATE:ZIP: Bluewave Builders Inc.822 A1A North # 310 Ponte Vedra FL 32082 TYPE OF CONSTRUCTION: REAL ESTATE NUMBER:ZONING:BUILDING USE GROUP:SUBDIVISION: 169519 0840 TIFFANY BY THE SEA JOB ADDRESS:PERMIT TYPE:DESCRIPTION: VALUE OF WORK: 89 NICOLE LN ROOF NON SHINGLE PLI-DECK WATERPROOFING $50000.00 FEES DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT LIST OF CONDITIONS Roll off container company must be on City approved list . Container cannot be placed on City right-of-way. 1 BUILDING ROOF IN-PROGRESS INSPECTION REQUIRED INFORMATIONAL Notes: a. The roof sheathing for all new construction must remain uncovered until the Roof Sheathing Inspection is approved. b. All roofing projects require an In-Progress Inspection. c. Sheathing installation and replacement guidelines per APA. d. Underlayment must conform to FBC-R Table 905.1.1 e. Shingles must conform to ASTM D3161 G or H, or ASTM D7158 F NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION. ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES . ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY. 1 of 2Issued Date: 1/26/2022 PERMIT NUMBER ROOF21-0097 ISSUED: 1/26/2022 EXPIRES: 7/25/2022 ROOF NON SHINGLE PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 BUILDING PERMIT 455-0000-322-1000 0 $305.00 BUILDING PLAN CHECK 455-0000-322-1001 0 $152.50 STATE DBPR SURCHARGE 455-0000-208-0700 0 $6.86 STATE DCA SURCHARGE 455-0000-208-0600 0 $4.58 TOTAL: $468.94 2 of 2Issued Date: 1/26/2022 PERMIT NUMBER ROOF21-0097 ISSUED: 1/26/2022 EXPIRES: 7/25/2022 ROOF NON SHINGLE PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 Final Plumbing Final Electrical Final HVAC CC Final Final Building* Swimming Pool Steel Swimming Pool Safety Electrical Grounding & Bonding Swimming Pool Final (Bldg) Swimming Pool Final (PW) Formed Columns/ Beams* Masonry Cell Fill Structural Steel* OTHER: OTHER: OTHER: OTHER: OTHER: Power Pole Silt Fence Piers/ Stem Walls Underground Plumbing Underground Electric Foundation/ Footing Slab** Retaining Wall Footing Driveway Sewer (Building Dept) Sewer Tap (Utilities Dept) Rough Electric* Rough Plumbing/ Top Out* Rough Mechanical* House Wrap Wall Sheathing Roof Sheathing Tie-down Framing Connections Rough Framing Roofing In Progress Window/Door In-Progress Insulation Ceiling Insulation Wall Exterior Lath Stucco Scratch Coat Exterior Siding In-Progress Brick Flashing & Ties Early Power Gas Rough Gas Final* * When all rough electric, plumbing, mechanical are complete but before any work is covered up. * When all gas piping is complete and wallboard is installed but before gas is attached to any appliance. All outlets must be capped and pipe pressurized at a minimum of 15 lbs. * For new living space: When all construction work including electrical, plumbing, mechanical, exterior finish, grading, required paving and landscaping is complete and the building is ready for occupancy, but before being occupied Additional inspections may apply to your project if your project contains these elements: INSPECTIONS REQUIRED FOR BUILDING PERMITS To verify compliance with building codes, inspections of the work authorized are required at various points of the construction. The following inspections are typically required for residential projects: Date: Initial: Date: Initial: _____________________________________________________ Permit Type ____________________________________________________ Permit No. __________________________________________________________ Job Address ____________________________________________________ Contractor POST THIS CARD WITH PERMITS AND PERMIT DOCUMENTATION IN FRONT OF BUILDING Construction Hours per City Code: 7am—7pm Weekdays; 9am—7pm Weekends Building Department Public Works/Utilities Fire Department Phone: 904-247-5826 Phone: 904-247-5834 Phone: 904-630-4789 Fax: 904-247-5845 Fax: 904-247-5843 Fax: 904-630-4203 * When forms and reinforcing steel, anchor bolts, sleeves and inserts, and all electrical, plumbing and mechanical work is in place, but before concrete is poured. * When all structural steel members are in place and all connections are complete, but before such work is covered or concealed. ** FORM BOARD ELEVATION CERTIFICATE MUST BE ON-SITE FOR SLAB INSPECTION ROOF21-0097NOT FILED ROOF21-0097 Page 1 of 4 Updated 10/17/18 PRODUCT APPROVAL INFORMATION SHEET FOR THE CITY OF ATLANTIC BEACH, FLORIDA (*REQUIRED) *Project Address: _________________________________________________________________________ Permit #: ___________________________ *Owner/Project Name: _______________________________________________________________________________________________________ As required by Florida Statute 553.842 and Florida Administrative Code Rule 9B-72, please provide the information and product approval number(s) for the building components listed below as applicable to the building construction project for the permit number listed above. You should contact your product supplier if you do not know the product approval number for any of the applicable listed products. Information regarding statewide product approval may be obtained at: www.floridabuilding.org. Category/Subcategory Manufacturer Product Description Limitation of Use State # Local # A. EXTERIOR DOORS 1. Swinging 2. Sliding 3. Sectional 4. Garage Roll-Up 5. Automatic 6. Other B. WINDOWS 1. Single hung 2. Horizontal slider 3. Casement 4. Double hung 5. Fixed 6. Awning 7. Pass-through 8. Projected 9. Mullion 10. Wind breaker 11. Dual action 12. Other 83 Nicole Lane Susan Walsh Simonton Vinyl window 5167.1 89 Nicole Lane Jack Willis ROOF21-0097 Page 2 of 4 Updated 10/17/18 Category/Subcategory Manufacturer Product Description Limitation of Use State # Local # C. PANEL WALL 1. Siding 2. Soffits 3. EIFS 4. Storefronts 5. Curtain walls 6. Wall louvers 7. Glass block 8. Membrane 9. Greenhouse 10. Synthetic stucco 11. Other D. ROOFING PRODUCTS 1. Asphalt shingles 2. Underlayments 3. Roofing fasteners 4. Nonstructural metal roof 5. Built-up roofing 6. Modified bitumen 7. Single ply roofing 8. Roofing tiles 9. Roofing insulation 10. Waterproofing 11. Wood shingles/shakes 12. Roofing slate 13. Liquid applied roofing 14. Cement-adhesive coats 15. Roof tile adhesive 16. Spray applied polyurethane roof 17. Other NA Pli-dek fluid applied waterproofing 15027.2 Page 4 of 4 Updated 10/17/18 In addition to completing the above list of manufacturers, product description and State approval number for the products use d on this project, the Contractor shall maintain on the job site and available to the Inspector, a legible copy of each manufacture r's printed specifications and installation instructions along with this Product Approval Sheet. I certify that this product approval list is true and correct to the best of my knowledge. I further certify that use of diff erent components other than the ones listed in this document must be approved by the Building Official. *Contractor Name (Print Name):_________________________________ *Contractor Signature: ___________________________________________ *Company Name: __________________________________________________________________________________________________________ *Mailing Address: __________________________________________________________________________________________________________ *City: _______________________________________________ *State: ______________________ *Zip Code: _______________________________ *Telephone Number: ___________________________________ *E-mail Address: _______________________________________________________ Cell Phone Number: _____________________________________ Fax Number: _________________________________________________________ Paul Zebouni Bluewave Builders, Inc. 822 A1A N suite #310 Ponte Vedra Beach FL 32082 248-0395 PZ@bluewavebuilders.com 248-0395 Scan here to visit the Pli-Dek website Rev. 12.2020 TESTS PROCEDURE LIMITATIONS RESULTS 1.ASTM D1242 Abrasion Test 1000 Revolutions @ 1000 gm load No. 80 TP alum. Ox. Grit. Allowable abrasion loss is 5% Pli-Dek average loss: 2.9% 2.ASTM D570 Water Absorption of Plastics 24 hour immersion in distilled water Allowable absorption by weight: 15% Pli-Dek within specification average weight: 12.6% 3.ASTM E96 Water Vapor Transmission Inverted water method wetted on one side Allowable 2.4 gms/24 hours per 100 square inch Vapor transmission: .31 grams/24 hours per 100 square inch 4.ASTM Pending Percolating Test 2” diameter tube/48” water column. 48 hours at room temp.- 72 °F RH 50% Allowable total drop 1% in 48 hours Pli-Dek percolation drop: .02% 5.ASTM C297 Bond Strength Material is placed in a sandwich between plywood tensile load applied to the plane of the sandwich Tests conducted to determine relative bond strengths usually within limits of plywood bond strength Pli-Dek bond strength exceeded the strength of plywood on 5 separate tests with plywood bond failure at 126 psi 6.ASTM G23 Weatherability Test 2000 hours Atlas Twin Arc Weatherometer (equivalent to 6 yrs. Natural weathering) No surface cracking, blistering, chalking, or other deleterious effects Pli-Dek had no signs of deleterious effects 7.ASTM D2707L/D270T Tensile Strength Specimens are pulled in longitudinal plane Effects of weathering on strength: min. 290 psi After weathering: D2707L 1505 psi, D270T 411 psi 8.ASTM E84 Surface Burning 240 feet per minute in fire chamber Effects of surface burning on min of 10 minutes 10-minute Class A 30-minute extended Pass 9.ASTM A756 Freeze-Thaw Cycling 3 Cycles: 24 hrs freezer @ -40 °C 24 hrs in oven @ 80 °C 75% RH No evidence of cracking, splitting, blistering or other deleterious effect Pli-Dek had no signs of deleterious effects 10.ASTM C67 Freeze-Thaw Cycling 50 Cycles: 24 hrs in oven @ 235 °F 24 hrs freezer @ 32 °F 4 hrs thaw @75/50%RH Max. allowable weight loss of 1% Percentage of weight loss was less 1%. No breakage or cracking on 5 test specimens 11.ASTM C150-72 Compressive Strength Pressure exerted to crush sample Low concrete 750 psi to high of 3000 psi Pli-Dek average: 6075 psi 12.ASTM Pending Impact Test 2lb. Steel ball, drop height of 8ft. No signs of cracking, chipping, flaking or delamination Pli-Dek had no signs of deleterious effects 13.ASTM Pending Concentrated Load 5 cycles: 500lbs. Load on 1” diameter cylinder To measure surface of penetration Nominal residual readings 14.ASTM D2299 Chemical Resistance Reagents applied to surface, then placed 16 hrs in oven @122 °F Determine effects of reagents to surface Pli-Dek had no signs of deleterious effects 15.ASTM C 1028-96 Static Coefficient of Friction Specimens are tested in both wet and dry conditions; Five each in longitudinal and five each in the transverse direction. The ADA minimum requirement for static coefficient of friction is an average value of no less than 0.65 Tests results after conducted in wet and dry conditions: Pli-Dek average in dry condition was .835 and in wet condition .74 16.ASTM E108 Spread of Flame 10 minutes application of 1400 °F flame on surface Class “A” max. 6 feet Pli-Dek decks had a heat effect area averaging 9.5 inches 17.ASTM E108 Intermittent Flame 15 cycles: 2 minute application of 1400 °F flame, followed by 2 minutes with flame off Class “A” requires 15 intermittent cycles without displacement, spalling production of flying brands or flaming on underside Pli-Dek decks passed all requirements for a Class “A” deck 18.ASTM E108 Burning Brand 6” x 6” brands ignited by gas flame for 4 min., placed at intersection of vertical and horizontal joints of deck No flames of distress may occur on or below the decks or produce burning brands Pli-Dek decks passed test, qualifying system as a fire retardant roof/deck covering 19.ASTM E119 One-Hour System Burners generating up to one million BTU’s are lit beneath deck surface with minimum temperatures of 1400° F The exposed face of the deck may not rise in surface temp- eratures in excess of 250°F over ambient temperatures for 1 hour Although under surface of the deck was over 1400 °F after 65 minutes of intense flame, the average unexposed face temperature never rose above 163 °F 20.Factory Mutual 1-52 Wind Uplift Test Place the Factory Mutual 1-52 vacuum chamber onto the surface of the test specimen and evacuating the air within the chamber. During the air evacuation process, deflection readings were taken on the surface of the walking deck. See the Pli-Dek ICC-ES ESR- 2097 Report (Tables 3 and 4) for building height and exposure ratings. The “Wind Uplift Strength” of the “Partial” Pli-Dek Walking Deck System exceeds the capacity of Ramtech’s test fixture of 202 pounds per sq. ft. with a maximum deflection of 0.2 inches. PAGE 1 OF 1 (All tests on file and preformed over plywood surfaces by ICC ES (ICBO) Authorized Testing Labs) 150 Dascomb Road • Andover, MA 01810 • 800-364-0287 • www.plidek.com ©2019 Pli-Dek Systems, LLC. and other marks on this document are trademarks of ICP Building Solutions Group ROOF21-0097 Scan here to visit the Pli-Dek website Rev. 12.2020 TESTS PROCEDURE LIMITATIONS RESULTS 1.ASTM D1242 Abrasion Test 1000 Revolutions @ 1000 gm load No. 80 TP alum. Ox. Grit. Allowable abrasion loss is 5% Pli-Dek average loss: 2.9% 2.ASTM D570 Water Absorption of Plastics 24 hour immersion in distilled water Allowable absorption by weight: 15% Pli-Dek within specification average weight: 12.6% 3.ASTM E96 Water Vapor Transmission Inverted water method wetted on one side Allowable 2.4 gms/24 hours per 100 square inch Vapor transmission: .31 grams/24 hours per 100 square inch 4.ASTM Pending Percolating Test 2” diameter tube/48” water column. 48 hours at room temp.- 72 °F RH 50% Allowable total drop 1% in 48 hours Pli-Dek percolation drop: .02% 5.ASTM C297 Bond Strength Material is placed in a sandwich between plywood tensile load applied to the plane of the sandwich Tests conducted to determine relative bond strengths usually within limits of plywood bond strength Pli-Dek bond strength exceeded the strength of plywood on 5 separate tests with plywood bond failure at 126 psi 6.ASTM G23 Weatherability Test 2000 hours Atlas Twin Arc Weatherometer (equivalent to 6 yrs. Natural weathering) No surface cracking, blistering, chalking, or other deleterious effects Pli-Dek had no signs of deleterious effects 7.ASTM D2707L/D270T Tensile Strength Specimens are pulled in longitudinal plane Effects of weathering on strength: min. 290 psi After weathering: D2707L 1505 psi, D270T 411 psi 8.ASTM E84 Surface Burning 240 feet per minute in fire chamber Effects of surface burning on min of 10 minutes 10-minute Class A 30-minute extended Pass 9.ASTM A756 Freeze-Thaw Cycling 3 Cycles: 24 hrs freezer @ -40 °C 24 hrs in oven @ 80 °C 75% RH No evidence of cracking, splitting, blistering or other deleterious effect Pli-Dek had no signs of deleterious effects 10.ASTM C67 Freeze-Thaw Cycling 50 Cycles: 24 hrs in oven @ 235 °F 24 hrs freezer @ 32 °F 4 hrs thaw @75/50%RH Max. allowable weight loss of 1% Percentage of weight loss was less 1%. No breakage or cracking on 5 test specimens 11.ASTM C150-72 Compressive Strength Pressure exerted to crush sample Low concrete 750 psi to high of 3000 psi Pli-Dek average: 6075 psi 12.ASTM Pending Impact Test 2lb. Steel ball, drop height of 8ft. No signs of cracking, chipping, flaking or delamination Pli-Dek had no signs of deleterious effects 13.ASTM Pending Concentrated Load 5 cycles: 500lbs. Load on 1” diameter cylinder To measure surface of penetration Nominal residual readings 14.ASTM D2299 Chemical Resistance Reagents applied to surface, then placed 16 hrs in oven @122 °F Determine effects of reagents to surface Pli-Dek had no signs of deleterious effects 15.ASTM C 1028-96 Static Coefficient of Friction Specimens are tested in both wet and dry conditions; Five each in longitudinal and five each in the transverse direction. The ADA minimum requirement for static coefficient of friction is an average value of no less than 0.65 Tests results after conducted in wet and dry conditions: Pli-Dek average in dry condition was .835 and in wet condition .74 16.ASTM E108 Spread of Flame 10 minutes application of 1400 °F flame on surface Class “A” max. 6 feet Pli-Dek decks had a heat effect area averaging 9.5 inches 17.ASTM E108 Intermittent Flame 15 cycles: 2 minute application of 1400 °F flame, followed by 2 minutes with flame off Class “A” requires 15 intermittent cycles without displacement, spalling production of flying brands or flaming on underside Pli-Dek decks passed all requirements for a Class “A” deck 18.ASTM E108 Burning Brand 6” x 6” brands ignited by gas flame for 4 min., placed at intersection of vertical and horizontal joints of deck No flames of distress may occur on or below the decks or produce burning brands Pli-Dek decks passed test, qualifying system as a fire retardant roof/deck covering 19.ASTM E119 One-Hour System Burners generating up to one million BTU’s are lit beneath deck surface with minimum temperatures of 1400° F The exposed face of the deck may not rise in surface temp- eratures in excess of 250°F over ambient temperatures for 1 hour Although under surface of the deck was over 1400 °F after 65 minutes of intense flame, the average unexposed face temperature never rose above 163 °F 20.Factory Mutual 1-52 Wind Uplift Test Place the Factory Mutual 1-52 vacuum chamber onto the surface of the test specimen and evacuating the air within the chamber. During the air evacuation process, deflection readings were taken on the surface of the walking deck. See the Pli-Dek ICC-ES ESR- 2097 Report (Tables 3 and 4) for building height and exposure ratings. The “Wind Uplift Strength” of the “Partial” Pli-Dek Walking Deck System exceeds the capacity of Ramtech’s test fixture of 202 pounds per sq. ft. with a maximum deflection of 0.2 inches. PAGE 1 OF 1 (All tests on file and preformed over plywood surfaces by ICC ES (ICBO) Authorized Testing Labs) 150 Dascomb Road • Andover, MA 01810 • 800-364-0287 • www.plidek.com ©2019 Pli-Dek Systems, LLC. and other marks on this document are trademarks of ICP Building Solutions Group ROOF21-0097 41610 Date Street, Suite 104, Murrieta, CA 92562 • 800-364-0287 • www.plidek.com ©2019 Pli-Dek Systems, LLC. and other marks on this document are trademarks of ICP Building Solutions Group Waterproof Deck Coating –Pli-Dek System Application Instructions PD-120 Rev. 5.4.2020 I.Substrate Inspection/ Preparation: A.General 1.All building permits are required by local authorities shall be produced by contractor, owner, and/or their agent. 2.All inspections, as required by local building authorities, shall be the responsibility of the contractor, owner, and/or their agent. 3.Verify all necessary tools and PPE according to the various SDS Sheets are on the job site. 4.For application instructions in Inclement Weather areas, refer to Waterproof Deck Coating –Pli-Dek System Application Instructions PD-120-IW. B.Traditional Plywood Substrates 1.Plywood shall be a minimum of 16mm, 5/8” (3/4” recommended) sound and dry, exposure 1 sheathing, and have a recommended span between supports of 410mm (16”) on center. All plywood shall be securely fastened to the supports with screws or ring shank nails spaced in accordance with APA guidelines and Building Code requirements. **Contact Pli-Dek, LLC. for installation approvals over OSB, pressure treated, or marine grade, etc. substrates. 2.Maximum deflection of the deck shall be less than L/360th of the span. 3.Framing or blocking must support all plywood edges, except as per APA guidelines; blocking is not required when tongue and groove plywood is used. 4.The plywood surface shall be clean, dry, and free of dirt, dust, oil, paint, or any other contaminants that may impair adhesion. 5.All plywood seams shall be staggered and gapped 3.2mm (1/8”). NOTE: If plywood is butted tightly, the seams shall be saw cut to provide a 3.2mm (1/8”) gap between sheets, except tongue & groove. Ensure that the tongue and groove section of the plywood is installed to allow for expansion. 6.All adjacent edges of the plywood sheets shall not be more than 0.78mm (1/32”) out of plane (i.e. above or below each other). 7.Plywood should be installed with a 6.4mm/.3m (1/4”) per linear foot slope. Decks with parapet enclosures must be sloped to a drain or scupper. 8.Any variation from the framing specifications mentioned in Section I, requires written approval and system recommendations from Pli-Dek, LLC. C.Flashing 1.The following items that involve flashing must be completed or adhered to: a)Flashing shall be minimum 26 gauge galvanized, bonderized sheet metal. (Contact Pli-Dek for Alternatives). b)Ensure ALL metal flashing is wiped clean with a solvent to ensure oils are completely removed from the Surface. Dissimilar metals, such as Copper and galvanized, should NEVER come in direct contact with each other, please contact Pli-Dek for instructions on dissimilar metals. PAGE 1 OF 9 ROOF21-0097 41610 Date Street, Suite 104, Murrieta, CA 92562 • 800-364-0287 • www.plidek.com ©2019 Pli-Dek Systems, LLC. and other marks on this document are trademarks of ICP Building Solutions Group Waterproof Deck Coating – Pli-Dek System Application Instructions PD-120 Rev. 5.4.2020 c)Openings shall be flashed before installation of doors and sliders. NOTE: If doors or sliders have been installed without proper flashing, we recommend they be removed, and proper flashing installed. d)All penetrations, including posts, or other objects that protrude through the deck shall be installed and flashed prior to applying the Pli-Dek materials. e)All decks with a parapet surround require a scupper not less than 76mm (3”) wide, and 100mm (4”) high, spaced a maximum of 3.65m (12’) apart. Any scuppers or overflows shall be installed and flashed prior to applying Pli-Dek materials. f)All deck drains must be flanged, and properly installed to a proper depth. NOTE: Brass drains with a sheet metal flange are recommended. Pli-Dek requires a galvanized or stainless-steel drain as per Drain Detail, PD-24, on all plywood installations. Please contact Pli-Dek for help in acquiring these drains. Do not use plastic, cast iron, or shower drains. If copper drains are used, please contact Pli-Dek for instructions on dissimilar metals. The use of plastic deck drains will void warranty. g)Gravel stops shall have a maximum ground dimension of 3/16”. h)All flashing must be attached to the substrate with galvanized ring shank nails a minimum 25mm (1”) length. i)All flashing shall overlap adjacent pieces, a minimum of 100mm (4”), installed not to “buck” water, and be caulked horizontally and vertically with a Polyurethane Sealant per ASTM C 920, such as Sika-1a or 221 or equivalent, at the furthermost edge with a ¾” bead of sealant between any pieces of flashing that adjoin. (Surface caulking is NOT acceptable). j)(Optional) All vertical flashing and door pans shall be coated with Fiberglass and PD Resin or PD Flash Coat and Flash Coat Seam Tape or self-adhering drywall mesh tape, GU80-1 Top Coat, and GS88 Pigmented Sealer at the time of applying each product. Door pans do not need Top Coat and Sealer. k)Deck/Wall interfaces and all stairs must be flashed. l)When copper flashing/drains are used, ensure that all galvanized metal; such as, nails, staples, lath, drains, etc. does not come into contact with copper (do not allow any dissimilar metals to come in contact with each other). The contact of the two dissimilar metals will create rust and corrosion (electrolysis). **Contact Pli-Dek, LLC for additional details and recommendations. m)Contact Pli-Dek, LLC for written approval on flashing details that vary or are not included in Pli-Dek Details. D.Sloping 1.It’s the General Contractor’s, his representative’s, or individual owner’s responsibility to assure adequate drainage. 2.All plywood substrates are recommended to be sloped ¼” per foot. PAGE 2 OF 9 41610 Date Street, Suite 104, Murrieta, CA 92562 • 800-364-0287 • www.plidek.com ©2019 Pli-Dek Systems, LLC. and other marks on this document are trademarks of ICP Building Solutions Group Waterproof Deck Coating – Pli-Dek System Application Instructions PD-120 Rev. 5.4.2020 3.If auxiliary slope is required, Slope Mix - DP may be applied. (See Sloping Application Instructions SP-121 for complete details and limitations). When this type of sloping will not accommodate the problem, then drains become a necessity. 4.Pli-Dek requires a galvanized or stainless-steel drain as per Drain Detail, PD-24, on all plywood installations. Please contact Pli-Dek for help in acquiring these drains. Do not use plastic, cast iron, or shower drains. If copper drains are used, please contact Pli-Dek for instructions on dissimilar metals. 5.The alternatives available for proper drainage are the responsibility of the General Contractor. Contact Pli-Dek, LLC. for complete details. 6.Additional sloping required on a project should be confirmed through a written proposal given by the trained applicator prior to the commencement of work. II.Mixing Instructions: A.GU80-1 Gray Base {Base Coat} 1.Pour 3.8L (1 gallon) of GU80-1 Liquid Admixture into a clean 19L (5 gallon) plastic container. 2.Add one 21kg (46lb.) bag of GU80-1 Gray Base and mix thoroughly for 3 to 4 minutes. Use a Wind-lock B-M1 mixing blade, or equivalent, powered by a 13mm (1/2”) variable speed drill, capable of producing 1000 RPMs. TIP: In areas subject to extremely dry and/or hot climates, it may be necessary to add water (up to .47L [1 pint] per mix). To avoid flash drying, it may be necessary to chill the GU80-1 Liquid Admixture before mixing. Proper PPE should be worn when working with all Pli-Dek products. B.GU80-1 Top Coat {Screed Coat & Knockdown Texture} 1.Pour 4.75L (1.25 gallons) of GU80-1 Liquid Admixture into a clean 19L (5-gallon) plastic container. 2.Add one 21kg (46 lbs.) bag of GU80-1 Top Coat powder. Mix thoroughly for 3 to 4 minutes, with a Wind-lock B-M1 mixing blade, or equivalent, powered by a 13mm (1/2 inch0 variable speed drill, capable of producing 1000 RPMs. TIP: In areas subject to extremely dry, and/or hot climates, it may be necessary to add water (up to .47L {1 pint} per mix). In order to avoid flash drying it may be necessary to chill the GU80-1 Liquid Admixture before mixing. Proper PPE should always be worn when working with Pli-Dek Products. 3.Pli-Dek products must be stored in the shade to prevent overheating and reduction of pot life. 4.If colored cement is required, a Pli-Dek recommended tint pack may be added to the mix to achieve the desired color. NOTE: to ensure that all the colorant is dispersed out of the container. 5.All mixes must be consistent (use the same mix ratios) to maintain color consistency. C.GU80-1 Custom Top Coat 1.Pour 4.75L (1.25 gallons) of GU80-1 Liquid Admixture into a clean 19L (5-gallon) plastic container. PAGE 3 OF 9 41610 Date Street, Suite 104, Murrieta, CA 92562 • 800-364-0287 • www.plidek.com ©2019 Pli-Dek Systems, LLC. and other marks on this document are trademarks of ICP Building Solutions Group Waterproof Deck Coating – Pli-Dek System Application Instructions PD-120 Rev. 5.4.2020 2.Add one 21kg (46 lbs.) bag of GU80-1 Custom Top Coat powder. Mix thoroughly for 3 to 4 minutes, with a Wind-lock B-M1 mixing blade, or equivalent, powered by a 13mm (1/2” variable speed drill, capable of producing 1000 RPMs. TIP: In areas subject to extremely dry, and/or hot climates, it may be necessary to add water (up to .47L {1 pint} per mix). In order to avoid flash drying it may be necessary to chill the GU80-1 Liquid Admixture before mixing. Proper PPE should always be worn when working with Pli-Dek Products. 3.Pli-Dek products must be stored in the shade to prevent overheating and reduction of pot life. 4.If colored cement is required, a Pli-Dek recommended tint pack may be added to the mix to achieve the desired color. NOTE: to ensure that all the colorant is dispersed out of the container. 5.All mixes must be consistent (use the same mix ratios) to mainta in color consistency. III.Application: A.General: 1.Ensure that the plywood surface has been prepared in accordance with Section I. 2.Ensure that all proper flashings are in place. 3.Air temperature for application of the GU80-1 Gray Base must be between 4°C (40°F) and 43°C (110°F) and must remain so for a minimum of 2 - 6 hours. Ensure humidity levels are low. Do not apply over any standing water, contact Pli-Dek for additional information. B.Plywood Deck Preparation: 1.Install PD Seam Paper on all sides of plywood. 2.Lay out 2.5 lbs/sq yd G60 Hot Dipped Galvanized Metal Lath in a staggered pattern over the entire plywood surface overlapping the metal flashing, to the edge of the deck surface. 3.Overlap all edges of metal lath, a minimum of 13mm (3/4”). 4.Offset metal lath edges a minimum of 150mm (6”) from plywood seams. (as per Deck Plan Detail, PD-1). 5.Secure metal lath to plywood with a minimum 22mm (7/8”) crown by a minimum 16mm (5/8”) long corrosion resistant staples spaced approximately 1½” on center around the perimeter and on overlapped lath seams, and 75mm (3”) in the field (average 12 staples per square foot). 6.Additional staples spaced every 1½” on center are required where the metal lath overlaps as well as the seam paper, as installed in Section I. C.Base Coat Application: 1.Mix the GU80-1 Gray Base as described in Section II – A. 2.Pour the GU80-1 Gray Base over the metal lath and trowel the product using the lathing as a screed, filling all voids at a rate of 25 - 30 square feet per mix. The metal lath must be completely covered in the GU80-1 Gray Base. PAGE 4 OF 9 41610 Date Street, Suite 104, Murrieta, CA 92562 • 800-364-0287 • www.plidek.com ©2019 Pli-Dek Systems, LLC. and other marks on this document are trademarks of ICP Building Solutions Group Waterproof Deck Coating – Pli-Dek System Application Instructions PD-120 Rev. 5.4.2020 3.Allow the GU80-1 Gray Base to fully cure (approximately 4-6 hours depending on environmental conditions) prior to applying the next application. If the base coat does not cover the lath completely, a screed coat of GU80-1 Gray Base or GU80- 1 Top Coat is required. D.Screed Coat Application: 1.Screed coat may not be necessary in all applications. Contact Pli-Dek, LLC for application details and recommendations. 2.Prior to the screed coat application, remove any high or rough edges using a hand grinding stone or scraper. 3.The deck must be free of all surface contaminants, such as dust, dirt, etc., which will impair the adhesion of the Pli-Dek GU80-1 Top Coat or GU80-1 Custom Top Coat. 4.Mix the GU80-1 Top Coat or GU80-1 Custom Top Coat as described in Section II – B or C. 5.Trowel a screed coat over the GU80-1 Top Coat or GU80-1 Custom Top Coat at a rate of 150 square feet per mix. Allow to fully cure (approximately 2 - 6 hours). E.Pli-Dek “F” Fiberglass & Resin: PD Resin Application: 1.**This application becomes required when job conditions may experience excessive movement. Examples: cantilevered decks, large spanning decks, or if the dimensions of the deck are approximately 8’ x15’ or larger, or joist spacing greater than 16” O.C., etc. Contact Pli-Dek, LLC for written recommendations. Some geographic locations may require the Fiberglass and PD Resin Coating in ALL applications. Contact Pli-Dek, LLC for written verification. 2.First Coat: a)The Pli-Dek Applicator must have sole right of access to the specified areas for the time needed, in order to complete the application of the Pli-Dek System and obtain an adequate cure. b)Air temperature for application of the PD Resin and Fiberglass Coat must be between 4°C (40°F) and 43°C (110°F) and must remain so in the acceptable range until the product has cured. c)Mix the PD Resin using a mechanical mixer at slow speed for approximately 1 minute or until completely homogenous. d)The deck must be free of all surface contaminants, such as dust, dirt, etc., which will impair the adhesion of the PD Resin. The Pli-Dek GU80-1 Gray Base must be smooth so that the fiberglass properly adheres to the surface. e)Lay out the ¾ oz fiberglass mat over entire deck surface extending to all edges of the deck and up all vertical transitions. Overlap fiberglass mat seams a minimum of 1/4” to a maximum of 1/2”. f)Apply the PD Resin over fiberglass mat, at a rate of approximately 40 - 50 square feet per gallon with a trowel. Allow to completely cure, approximately 6 - 8 hours depending on environmental conditions. PD Resin must completely penetrate through the fiberglass mat. PD Resin should not be exposed to construction traffic. PAGE 5 OF 9 41610 Date Street, Suite 104, Murrieta, CA 92562 • 800-364-0287 • www.plidek.com ©2019 Pli-Dek Systems, LLC. and other marks on this document are trademarks of ICP Building Solutions Group Waterproof Deck Coating – Pli-Dek System Application Instructions PD-120 Rev. 5.4.2020 3.Optional: a)A screed coat of GU80-1 Top Coat can be applied over the fiberglass and PD Resin application in order to make a smoother surface, or to help protect the PD Resin if prolonged exposure to construction trade traffic is anticipated. F.Finish Options: 1.Preparation: a)Prior to any finish coat installation, the following must be completed: i.Grind any rough areas, being careful not to damage Fiberglass and PD Resin coat. Rough areas will affect the aesthetic appearance of the finished product. ii.The deck must be free of all surface contaminants, such as dust, dirt, etc. which will impair the adhesion of the Finish Coats. 2.Knockdown Texture Finish: a)Air temperature for application of the Knockdown Texture Coat must be between 40°F and 110°F and must remain so for a minimum of 8 hours. b)Mix the GU80-1 Top Coat as described in Section II - A. c)Using a hopper gun, spray the Knockdown Coating over the entire deck surface at a rate of 175 square feet per mix. CAUTION: AS WITH ANY SPRAY MATERIAL, BE CERTAIN TO PROTECT ALL SURROUNDING AREAS FROM OVER-SPRAY. d)When the material begins to dry, knock down the material with a trowel. TIP: In order to eliminate footprints, we suggest wearing metal spiked shoes (golf shoes) during this process. e)Allow the Knockdown to dry a minimum of 2 - 6 hours, depending on weather. f)Remove any sharp edges by scraping the surface with a scraper or trowel. g)Air temperature for application of the GS88-1 Pigmented Sealer must be between 40°F and 110°F and must remain so for a minimum of 8 hours. Ensure humidity levels are low. Do not apply over moisture. h)The deck must be free of all surface contaminants, such as dust, dirt, etc., which will impair adhesion of the GS88-1 Pigmented Sealer. i)Mix the GS88-1 Pigmented Sealer thoroughly with the use of mechanical mixers. All containers should be boxed and mixed to ensure consistent coloring throughout. j)Apply the GS88-1 Pigmented Sealer over the dry Knockdown application at a rate of 100 square feet per gallon using a 19mm (¾”) paint roller nap, suitable for latex type coatings (2 coats may be necessary). k)Allow GS88-1 Pigmented Sealer coat to dry for a minimum of 6 hours. PAGE 6 OF 9 41610 Date Street, Suite 104, Murrieta, CA 92562 • 800-364-0287 • www.plidek.com ©2019 Pli-Dek Systems, LLC. and other marks on this document are trademarks of ICP Building Solutions Group Waterproof Deck Coating – Pli-Dek System Application Instructions PD-120 Rev. 5.4.2020 l)To make cleaning easier in high traffic areas, a coat of GS13 or PD Clear Sealer may be applied over the dry GS88-1 Pigmented Sealer at a rate of 200 square feet per gallon. Surface will become more slippery. Use of a non-skid agent is recommended. 3.Polymer Sand Finish: a)Air temperature for application of the Sand Finish must be between 4°C (40°F) and 43°C (110°F) and must remain so for a minimum of 8 hours. Do not apply over moisture. b)(Optional) Apply a bead of manufacturer’s recommended elastomeric joint sealant at all wall-to-deck junctions, wood posts, wrought iron posts, etc. c)Before application, mix PD Resin using a mechanical mixer at slow speeds for approximately 1 minute or until completely homogenous. d)Apply PD Resin, using a ¾” nap roller and a brush at a rate of 75 square feet per gallon, ensuring a constant wet edge while broadcasting the desired aggregate until refusal. Do not allow PD Resin to puddle. e)Broadcast aggregates of washed, dry, rounded, crystal silica sand, approximately 16 mesh at a rate of 100 lbs. per 100 square feet or until refusal (depending on skid resistance requirements) into wet/uncured PD Resin. f)After full cure remove all excess aggregates. g)Air temperature for application of the GS88-1 Pigmented Sealer must be between 4°C (40°F) and 43°C (110°F), allow to completely cure, approximately 6 - 8 hours depending on environmental conditions. Ensure humidity levels are low. h)The deck must be free of all surface contaminants, such as dust, dirt, etc., which will impair adhesion of the GS88-1 Pigmented Sealer. i)Mix the GS88-1 Pigmented Sealer thoroughly using a mechanical mixer. All containers should be boxed and mixed to ensure consistent coloring throughout. j)Apply the GS88-1 Pigmented Sealer over the dry sand finish at a rate of 75 to 100 sq. ft. per gallon, (2 coats may be necessary) using a 19mm (¾”) paint roller nap, suitable for latex type coatings. k)Allow GS88-1 Pigmented Sealer coat to dry for a minimum of 6 hours. l)To make cleaning easier in high traffic areas, a coat of GS13 or PD Clear Sealer may be applied over the dry GS88-1 Pigmented Sealer at a rate of 200 square feet per gallon. (Surface will become more slippery. Use of a non-skid agent is recommended.) 4.Pli-Dek “U” (Underlayment): Note: The vertical leg of all flashings should be coated with Fiberglass and PD Resin or PD Flash Coat and Flash Coat Seam Tape or self-adhering drywall mesh tape. a)Air temperature for application of the Con-Dek “U” must be between 40°F and 110°F and must remain so for a minimum of 8 hours. Do not apply over any moisture. PAGE 7 OF 9 41610 Date Street, Suite 104, Murrieta, CA 92562 • 800-364-0287 • www.plidek.com ©2019 Pli-Dek Systems, LLC. and other marks on this document are trademarks of ICP Building Solutions Group Waterproof Deck Coating – Pli-Dek System Application Instructions PD-120 Rev. 5.4.2020 b)PD Resin should not be exposed to construction traffic. c)Mix the Pli-Dek GU80-1 Top Coat as described in Section II – A. d)Apply a screed coat of GU80-1 Top Coat over the entire deck at a rate of 150 square feet per mix. Allow to dry for a minimum of 2 - 6 hours. Mix the GU80-1 Top Coat as described in Section II – B. e)(Optional) Consult Tile Manufacturer or Sub for Recommendations: Broadcast aggregates of washed, dry, rounded crystal silica sand, approximately 16 mesh, at a rate of 100lbs. per 200 square feet. 5.Polyacrylic Smooth Finish: a)Air temperature for application of the polyacrylic smooth finish must be between 4°C (40°F) and 43°C (110°F) and must remain so for a minimum of 8 hours. It may be necessary to grind the rough ridges of the Base Coat to minimize chatter lines. b)Mix the GU80-1 Top Coat as described in Section II – B. c)Trowel a screed coat over the entire deck surface at a rate of 150 square feet per mix. Allow it to dry for a minimum of 6 hours. d)It may be necessary to apply an additional coat of GU80-1 Custom Top Coat to create a smoother finish. Coverage rate should be approximately 200 square feet per mix. **Please note: Surface will not be perfectly smooth and will have some imperfections/variations. e)(Optional) Apply a bead of Pli-Dek recommended elastomeric joint sealant to all wall-to-deck junctions, wood posts, wrought iron posts, etc. f)Air temperature for application of the GS88-1 Sealer must be between 4°C (40°F) and 43°C (110°F) and must remain so for a minimum of 8 hours. Ensure humidity levels are low. Do not apply over standing water. **Forced air electric heater maybe required. **. g)The deck must be free of all surface contaminants, such as dust, dirt, etc., which will impair adhesion of the GS88-1 Sealer. h)Mix the GS88-1 Sealer thoroughly with the use of mechanical mixers for 1 minute or until completely homogenous. i)All containers should be boxed and mixed to ensure consistent coloring throughout. Apply the GS88-1 Sealer over the polyacrylic smooth finish at a rate of 100 square feet per gallon using a 19mm (¾”) paint roller nap, suitable for latex type coatings (2 coats may be necessary). 6.Epoxy Stone Finish: a)Contact Pli-Dek, LLC for written instructions. 7.Custom Finish: Simulated Tile, Brick, and Stone a)Air temperature for application of the Custom Finish must be between 40°F and 110°F and must remain so for a minimum of 8 hours. b)Mix the GU80-1 Custom Top Coat as described in Section II - B. Add the selected color tint pack to establish the desired grout color. Note: All mixes must be consistent (use the same mix ratios) to maintain color consistency. PAGE 8 OF 9 41610 Date Street, Suite 104, Murrieta, CA 92562 • 800-364-0287 • www.plidek.com ©2019 Pli-Dek Systems, LLC. and other marks on this document are trademarks of ICP Building Solutions Group Waterproof Deck Coating – Pli-Dek System Application Instructions PD-120 Rev. 5.4.2020 c)The deck must be free of all surface contaminants, such as dust, dirt, etc. which will impair adhesion of the GU80-1 Custom Top Coat. d)Trowel a tinted GU80-1 Custom Top Coat over the entire deck surface at a rate of 150 square feet per mix. Allow to dry for a minimum of 2 – 6 hours. (Decorative scroll lines can be achieved at this step prior to screed coat drying, if no templates or tape are going to be used.) e)Install one of the various types of stencil patterns or install tape pattern over cured screed coat to achieve desired pattern finish. f)Mix the GU80-1 Custom Top Coat as described in Section II – B. g)Trowel a tinted screed coat over the stenciled or taped deck surface at a rate of 150 square feet per mix. Apply the desired texture while spreading the GU80 Custom Top Coat. Allow to dry for a minimum of 2 - 6 hours. h)Apply desired stain/shading with PD Stain using a low-pressure sprayer, soft broom, or sponge. Contact Pli-Dek, LLC. for complete details. i)Remove stencil or tape pattern. j)The deck must be free of all surface contaminants, such as dust, dirt, etc., which will impair adhesion of the GS13 or PD Clear Sealer. k)Apply a coat of PD Clear Sealer or GS13 Clear Sealer at a rate of 100 square feet per gallon. (2 coats may be necessary). Surface will become more slippery. Use of a non-skid agent is recommended. IV.Slip and Fall Precautions: OSHA, American Disabilities Act (ADA), and The Federal Housing Act (FHA) have now set enforceable standards for slip-resistance on pedestrian surfaces. Pli-Dek LLC recommends the use of angular slip-resistant aggregate in all coatings or flooring systems that may be exposed to wet, oily/greasy, or otherwise potentially slippery conditions. It is the end user’s responsibility to provide a flooring system that meets current safety standards. Pli-Dek Systems, Inc or its sales agents will not be responsible for injury incurred in a slip and fall accident. Please consult local building codes for the current coefficient of friction requirement. Disclaimer Information contained in this specification conforms to standard detail and product recommendations for the installation of the Pli-Dek products as of the date of publication of this document and is presented in good faith. Pli- Dek LLC assumes no liability, expressed or implied, as to the architecture, engineering or workmanship of any project. To ensure that you are using the latest, most complete information, contact Pli-Dek LLC, at: 41610 Date St, Suite 104 Murrieta, CA 92562 Tel.: (800) 364-0287 Website: www.plidek.com * The Trained Applicator Certificate indicates certain employees of the company have been instructed in the proper application of Pli-Dek products and have received copies of the Pli-Dek Application Instructions and Specifications. The Trained Contractor Program is not an apprenticeship. Each trained contractor is an independent company and bears responsibility for its own workmanship. Pli-Dek LLC assumes no liability for the workmanship of a trained contractor. PAGE 9 OF 9 Description: The Pli-Dek Waterproofing System is a 1-Hour, Class “A” Fire Rated deck system. It uses a poly-acrylic emulsion membrane, combined with elastomeric, acrylic, or cementitious finishes. The system consists of 2.5lbs/sq. yd. galvanized metal lath, base coat, and a wide range of finishes. This system offers high durability with low maintenance. . Uses: Waterproof Deck Coating Scan here to visit the Pli-Dek website 6\VWHP'DWD6KHHW–Pli'ek System Rev. 10.2020 SYSTEM DATE SHEET PLI-DEK SYSTEM WATERPROOFING OVER PLYWOOD SUBSTRATE •Plywood Balconies •Walking Decks •Stairways •Roof Decks •Interior & Exterior •New Construction •Rehabilitation Standards: The Pli-Dek System meets the requirements of the ASTM E119 for a 1-Hour Fire Rating and the ASTM E108 for a Class “A” Fire Retardant Roof. Job Conditions: The ambient air and surface temperature must be a minimum of 4.44°C (40°F) and a maximum of 43°C (110°F) and shall remain so for at least 24 hours. Do not install over wet substrates or in rainy conditions. The Pli-Dek installer shall inspect the substrate for any deficiencies and notify the architect or general contractor in writing of the corrections that need to be made before application of the Pli-Dek products. Color: The finish coat of the Pli-Dek System is available in Pli-Dek’s standard colors. Custom color matching is also available, refer to the Pli-Dek System brochure or contact Pli-Dek LLC. for further information. Packaging: The GU80-1 Powders are available in 46 lb. bags. The PD Resin, GU80-1 Liquid Admixture, GS88-1 Pigmented Sealer, and the GS99-1 or GS13 Sealer are supplied in 5 gallon pails. The flashing, metal lath, and staples are sold separately in various quantities. Shelf Life: One year from the ship date. Do not allow products to freeze. Do not store GU80-1 powders in wet or damp areas. Technical Data: Spread of Flame (ASTM E-108) Class “A” Freeze Thaw (ASTM C67-03) Pass 1-Hour (ASTM E119)Pass Bond Strength – Plywood (ASTM C-297) 126 psi Tensile Strength (ASTM D 2707) 1505 psi after weathering Impact Test (ASTM D-3320) No Cracking Water Transmission (ASTM E-96) 31g/24hrs. Abrasion Test (ASTM D-1242) 2.9% Static Coefficient of Friction (ASTM C-1028-96) 835 Limitations: Not for use in areas intended for vehicular traffic. Warranty: Contact Pli-Dek LLC. for warranty information. Technical Assistance: Pli-Dek LLC. or its local authorized representatives are available for technical assistance and/or inspections for the Pli-Dek line of products. 150 Dascomb Road • Andover, MA 01810 • 800-364-0287 • www.plidek.com ©2019 Pli-Dek Systems, LLC. and other marks on this document are trademarks of ICP Building Solutions Group Surface Burning (ASTM E84) 10-minute Class A 30-minute Extended Pass Decking for Wildland Urban Interface W.U.I. Listing No.8110-2327:0500 ROOF21-0097