345 BELVEDERE ST RESA21-0024 FL5177_R35_II_IN0514 07-20 PW 2X REV 12-14-21_11-
5
LU
I
3
0
X
<C
MODEL DESIGNATION:Simonton Series 07-20 Vinyl Fixed Window
MAXIMUM OVERALL NOMINAL SIZE:See Size Chart
DESIGN PRESSURE RATING:
USABLE CONFIGURATIONS:
GENERAL DESCRIPTION:
I
V.
_ 4 1/2"MAX.
1
3
<1
37"
74"
See Size Chart
0
The head and side jambs are extruded PVC. The wall thickness through
which the anchor screw penetrates is a minimum of 0.070".
23 1-t 4 1/2" O.C.
MAX. TYP.
<1
"W" MAX. OVERALL WIDTH
SIZE CHART
OVERALL SIZE
WI D TH HEIGHT
96"72"
84"
63"
////
DP RATING
*45.0 PSF
*50.0 PSF
160.0 PSF
4 1/2"
MAX.1 11
..1-
IIF
SM
:E
00-In-=1
2 I In
1 -L----21
SILICONE -
CAULK -&..
#8 X 1 1/4" WOOD
SCREW WITH 1.00" MIN SILL
EMBEDMENT INTO WOOD
MIN. EDGE DIST., SEE NOTES
SILICONE
CAULK
1/4" MAX. SHIM
r 2X BUCK
1
1
NO P.E. SEAL REQUIRED
INSTALLATION SUPPORTED
BY AAMA TEST REPORTS
#8 X 1 1/4" WOOD
SCREW WITH 1.00" MIN.
EMBEDMENT INTO WOOD
MIN. EDGE DIST., SEE NOTES
HEAD
--2X BUCK
1/4" MAX. SHIM
REV.
1
2
4
3
REVISIONS:
ADDED 37" X 84" UNIT SIZE.
UPDATED SIZE CHART PER NEW TESTING.
MIN. EDGE DIST. NOTE
ADDED NOTES 11 & 12 - AAMA 800
2X BUCK 7
#8 X 1 1/4" WOOD
SCREW WITH 1.00" MIN.
EMBEDMENT INTO WOOD 7
MIN. EDGE DIST., SEE NOTES
SILICONE CAUL
1
3
j-j
.-4-/
REVISED BY:
T.D.D.
T.D.D.
B.J. S.
LMH
1/4" MAX. SHIM
/E-SUL 0
JOjUr
JAMB
DATE:
06/06/12
10/31/12
06/17/15
10/7/16
NOTES:
1. This installation has been evaluated for use in locations adhering to the Florida Building Codes and where pressure requirements as determined by ASCE 7 Minimum
Design Loads for Buildings and Other Structures do not exceed the design pressure ratings herein, for use outside the H.V.H.Z.
2. All exterior perimeter surfaces of the window must be caulked. Interior caulking is optional unless noted otherwise.
3. Anchors shall be as specified and spaced as shown. Anchor embedment to base material shall be beyond wall dressing or stucco and into wood.
4. The responsibility for selection of Simonton products to meet any applicable local laws, building codes, ordinances, or other safety requirements rests solely with the
architect, building owner, or contractor.
5. Shims are optional. Max. shim stack is 1/4".
6. Wood bucks (by others) must be engineered and anchored properly to transfer loads to the structure.
7. When used in areas requiring impact protection this product REQUIRES the use of approved impact resistant shutters or other external protection.
8. Flashing should be applied using the ASTM E 2112 methodology appropriate for the opening into which the window is being installed.
9. Installation screws must be at least 3/4" from the edge of the wood.
10. Glazing shall comply with ASTM E 1300-04.
11. Use 100% pure silicone caulk compliant with AAMA 800 Section 1 - Sealant Specifications for use with Architectural Fenestration Products. Make sure surfaces are
completely free from all old caulk, damaged wood, wood fibers, grease, oil dirt, rust, mold or similar contaminants. Vacuum and clean opening surfaces completely.
A fully primed surface is recommended, but not required. Cleaning of all surfaces should be done the same day of which the silicone caulk is to applied. For more
details visit Simonton.com.
12. Caulk application: recommended air and surface temperatures at the time of application are to be between 40 and 90 degrees F. Insure all contact surfaces are
clean and dry including the new window(s). Use a backer rod on all joints >3/4" deep and/or wider than 1/4". Finished caulk joint should be a minimum of 3/8" deep
and make full contact with both the new window and structural opening surfaces. Silicone caulk should be forced into joint or compressed to assure full contact on
both surfaces and to expel any air pockets.
DISCLOSURE STATEMENT
This document is the property of Simonton Windows, which
retains all proprietory and other rights to its subject matter.
This document is provided to the recipient on the expressed
condition that it is not to be disclosed, reproduced in whole or
part, nor used in conjunction with the design, manufacture or
repair of goods for anyone other than Simonton Windows
without its consent.This restriction does not limit the
recipient's rights to utilize information contained in this
document which is properly obtained from another source.
FILE: IN0514
MATERIAL:
RMS FINISH:
EXCEPT AS NOTED
ALLOY & TEMPER:
WEIGHT:
SURFACE AREA:
FINISH TREATMENT:
VOLUME:
PERIMETER:
Dimensionol Tolerances
Unless Otherwise Specified
Decimals Angles
.X * .03
.XX i .01 0' 30 min.
.XXX * .005
SIMONTON'WIN D 0 W S
1 Cochrane Avenue
Pennsboro, WV 26415
SCALE:SHEET:
FIT 1 of 1
SERIES:
TITLE:
SIZE: DRAWING NO.:REV.:
B IN0514 4
DRAWN BY:DATE:
T.D.D.07/20/10
CHECKED BY: DATE:
APPRV'D BY:
07-20 PICTURE (FIXED) WINDOW
2X BUCK INSTALLATION (AS TESTED)
DATE: