Loading...
345 BELVEDERE ST RESA21-0024 FL5179_R32_II_IN0234 41-18 SL_2x REV 12-14-21_1MODEL DESIGNATION: MAXIMUM OVERALL NOMINAL SIZE: Single up to 73" x 63" DESIGN PRESSURE RATING: Positive: 30.0 PSF Simonton Horizontal Slider Series USABLE CONFIGURATIONS: GENERAL DESCRIPTION: 2" MAX. Negative: 30.0 PSF OX or X0 41-18 Vinyl Window The head, sill, and side jambs are extruded PVC. The wall thickness through which the anchor screw penetrates is a minimum of 0.070". r9" 0.C. MAX. TYP. 2" MAX.~ —+ 63" MAX. OVERALL FRAME HEIGHT I I 1 \ \ L CD 0 X 1 O _J } < X < 73" MAX. OVERALL FRAME WIDTH } #6 X 1 1/4" MIN. WOOD SCREW WITH 1.00" MIN. EMBEDMENT INTO WOOD MIN. EDGE DIST., SEE NOTES SILICONE CAULK SILICONE CAULK NO P.E. SEAL REQUIRED INSTALLATION SUPPORTED BY AAMA TEST REPORTS OHEAD 1 1/4" MAX. SHIM 2X BUCK #6 X 1 1/4" MIN. WOOD SCREW WITH 1.00" MIN. EMBEDMENT INTO WOOD MIN. EDGE DIST., SEE NOTES OSILL 2 2X BUCK 1/4" MAX. SHIM REV. #: REVISIONS: REVISED BY: DATE: 9 UPDATED PER NEW TESTING. T.D.D. 10/09/12 10 UPDATED SIZE PER NEW TESTING. T.D.D. 02/20/13 11 ADDED MIN. EDGE DIST. NOTE. T.D.D. 02/20/13 12 ADDED NOTES 11 & 12. LMH 07/07/16 13 UPDATED TO 7TH EDITION (2020) FBC LMH 02/15/21 #6 X 1 1/4" MIN. WOOD SCREW WITH 1.00" MIN. EMBEDMENT INTO WOOD MIN. EDGE DIST., SEE NOTES 2X BUCK 1/4" MAX. SHIM SILICONE CAULK CD, JAMB NOTES I. THIS INSTALLATION HAS BEEN EVALUATED FOR USE IN LOCATIONS ADHERING TO THE TEXAS & FLORIDA BUILDING CODE AND WHERE PRESSURE REQUIREMENTS AS DETERMINED BY ASCE 7 MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES DO NOT EXCEED THE DESIGN PRESSURE RATINGS HEREIN, FOR USE OUTSIDE THE H.V.H.Z. 2. ALL INTERIOR AND EXTERIOR PERIMETER SURFACES OF THE WINDOW MUST BE CAULKED. 3. ANCHORS SHALL BE SPECIFIED AND SPACED AS SHOWN ANCHOR EMBEDMENT TO BASE MATERIAL SHALL BE BEYOND WALL DRESSING OR STUCCO AND INTO WOOD. 4. THE RESPONSIBILITY FOR SELECTION OF SIMONTON PRODUCTS TO MEET ANY APPLICABLE LOCAL LAWS, BUILDING CODES, ORDINANCES, OR OTHER SAFETY REQUIREMENTS RESTS SOLELY WITH THE ARCHITECT, BUILDING OWNER, OR CONTRACTOR. 5. SHIMS ARE OPTIONAL. MAXIMUM SHIM STACK IS 1/4". 6. WOOD BUCKS (BY OTHERS) MUST BE ENGINEERED AND ANCHORED PROPERLY TO TRANSFER LOADS TO THE STRUCTURE. WOOD BUCKS SHALL BE SPRUCE -PINE -FIR. WOOD MINIMUM SPECIFIC GRAVITY = 0.42 PSI. 7. WHEN USED IN AREAS REQUIRING IMPACT PROTECTION, THIS PRODUCT REQUIRES THE USE OF APPROVED IMPACT RESISTANT SHUTTERS OR OTHER EXTERNAL PROTECTION. 8. FLASHING SHOULD BE APPLIED USING THE ASTM E 2112 METHOD APPROPRIATE FOR THE OPENING INTO WHICH THE WINDOW IS BEING INSTALLED. 9. INSTALLATION SCREWS MUST BE AT LEAST 1/2" FROM THE EDGE OF THE WOOD. 10. THIS PRODUCT COMPLIES WITH ASTM E 1300. II. USE A BACKER ROD ON ALL JOINTS >3/4" DEEP AND/OR WIDER THAN 1/4". FINISHED CAULK JOINT SHOULD BE A MINIMUM OF 3/8" DEEP. DISCLOSURE STATEMENT This document is the property of Simonton Windows, which retains all proprietary and other rights to its subject matter. This document is provided to the recipient on the expressed condition that it is not to be disclosed, reproduced in whole or part, nor used in conjunction with the design, manufacture or repair of goods for anyone other than Simonton Windows without its consent. This restriction does not limit the recipient's rights to utilize information contained in this document which is properly obtained from another source MATERIAL: RMS FINISH: EXCEPT AS NOTED ALLOY & TEMPER: WEIGHT: VOLUME: SURFACE AREA: PERIMETER: FILE: FL 5179 FINISH TREATMENT: Dimensional Tolerances Unless Otherwise Specified Decimals Angles .X±.03 .XX ± .01 0' 30 min. .XXX ± .005 SIMONTON° UU WINDOWS 1 Cochrane Avenue Pcnnsboro, WV 26415 SIZE: B DRAWING NO.: IN0234 REV.: 13 DRAWN BY: T.D.D. DATE: 02/01/08 CHECKED BY: DATE: SCALE: FIT SHEET: 1 of 1 APPRV'D BY: DATE: SERIES: 41-18 HORIZONTAL SLIDER TITLE: 2X BUCK INSTALLATION