345 BELVEDERE ST FL24397_R6_II_11030-001-1stCoast-5V Crimp Panel non-structural-CertRepRev8_1
Metal Roof Certification & Listing Program
Certification Report
11030-001-KCI
145 Limekiln Road, Suite 100B Issue Date: 9/01/2017
New Cumberland, PA 17070 Revision Date: 1/11/2021
www.keystonecerts.com Expiration Date: 10/12/2025
Refer to www.keystonecerts.com to ascertain the ongoing status of this Certification Report. Approval of building products and/or materials can only be granted by
the building official having jurisdictional legal authority. Keystone Certifications, Inc. does not endorse or make warranties with respect to product performance or
suitability of a product for a given use.
Construction Specifications Institute (CSI) Category:
Division: 07 00 00 – Thermal & Moisture Protection
Section: 07 41 13 – Metal roof and wall panels
1. Program Licensee:
1st Coast Metal Roofing Supply
186 SR 207
East Palatka, FL 32131
386-325-0242
http://www.1stcoastmrs.com/
2. Certified Roof Covering:
1st Coast Metal Roofing Supply’s Model 5V Crimp Panel
non-structural through-fastened minimum 26 gauge
metal roof and wall panels installed over nominal 7/16”
OSB sheathing roof deck for use in new construction, re-
roofing and re-covering applications.
3. Scope of Certification:
This Certification Report provides technical data
substantiating that the use of the certified roof covering
and the evaluated roof systems are in compliance with
the following:
• 2020 Florida Building Code - Building, 7th Edition,
Section 1504.3.2.
• Florida Product Approval Rule 61G20-3.
Properties Evaluated:
• Wind Uplift Resistance
This Certification Report was used to qualify
Florida Product Approval FL 24397-R6.
4. Evaluated Roof System Description:
4.1. Roof Covering: 5V Crimp Panel metal roof and
wall covering panels are cold roll-formed from minimum
26 gauge ASTM A792 Grade 50 steel sheet. The panels
are aluminum-zinc alloy coated per ASTM A792 (AZ50),
and shall be installed in accordance with the
manufacturer’s instructions and this Certification Report.
4.2. Roof Deck: 5V Crimp metal roof and wall panels
are certified for use over solid or closely-spaced, nominal
7/16” OSB sheathing complying with 2020 Florida
Building Code - Building, 7th Edition, Section 2303.1.8
with a minimum slope of 25% (3:12).
4.3. Anchorage: 5V Crimp Panel metal roof and wall
panels shall be through-fastened to the roof deck using
#9-15 x 1-1/2” Woodbinder ST-XL hex-head wood screws
with EPDM-sealing washer or equivalent, as specified in
Table 1, applied in the patterns described in Appendix 1.
4.4. Underlayment: 5V Crimp Panel metal roof and
wall panels in new construction applications shall be
installed over underlayment meeting the applicable
material type and attachment details specified in 2020
Florida Building Code - Building, 7th Edition Table
1507.1.1.1., the manufacturer’s installation instructions
and this Certification Report.
Metal Roof Certification & Listing Program
Certification Report
11030-001-KCI
Page 2 of 5
Refer to www.keystonecerts.com to ascertain the ongoing status of this Certification Report. Approval of building products and/or materials can only be granted by
the building official having jurisdictional legal authority. Keystone Certifications, Inc. does not endorse or make warranties with respect to product performance or
suitability of a product for a given use.
5. Installation
5V Crimp Panel metal roof and wall panels in new
construction applications shall be installed in accordance
with the 2020 Florida Building Code - Building, 7th
Edition, Section 1507.4, the manufacturer’s published
installation instructions and this Certification Report.
5V Crimp Panel metal roof and wall panels in re-roofing
and re-covering applications may be installed over a
single layer of existing shingles and shall be installed in
accordance with the 2020 Florida Building Code Code -
Building, 7th Edition, Sections 1507.4 & 1511, the
manufacturer’s published installation instructions and
this Certification Report.
The manufacturer’s installation instructions shall be
made available at the time of installation. If there are
differences between this report and the manufacturer’s
installation instructions, this report shall take
precedence.
6. Product Performance
The performance of the 5V Crimp Panel non-structural
through-fastened metal roof and wall panels described
in this Certification Report has been determined in
accordance with:
• UL 580-06, Tests for Uplift Resistance of Roof
Assemblies.
• UL 1897-04, Uplift Tests for Roof Covering Systems.
As tested & reported by the following independent
accredited laboratory:
Laboratory Report Ref.
Force Engineering & Testing 99-0284T-15A & B
Note: The UL 1897-04 standard is equivalent to the UL
1897-2012 standard.
6.1. Wind Resistance
The allowable design uplift pressures for 5V Crimp Panel
anchored as described in Appendix 1, when tested in
accordance with the referenced standards with an
applied safety factor of 2.0 are found in Table 1.
Table 1
Description Anchor
Pattern
Anchor
Man’f &
Model
Max
Design
Uplift
Pressure
Over 7/16” OSB
Sheathing
A
(16” O.C.)
Woodbinder
ST-XL -52.5 psf
Over 7/16” OSB
Sheathing
B
(24” O.C.)
Woodbinder
ST-XL -63.5 psf
7. Conditions of Use
5V Crimp Panel non-structural through-fastened metal
roof and wall panels must be insulated against other
materials or metals including concrete, lead, copper and
treated lumber that contains corrosive materials.
8. Limitations of Use
5V Crimp Panel non-structural through-fastened metal
roof and wall panels are not qualified for use in the High
Velocity Hurricane Zone (HVHZ).
Fire classification, shear diaphragm design, roof deck
design & attachment to supporting members are not
within the scope of this Certification Report.
Roof support framing shall comply with 2020 Florida
Building Code - Building, 7th Edition, Chapter 22 for
steel, Chapter 23 for wood and Chapter 16 for structural
loading.
Metal Roof Certification & Listing Program
Certification Report
11030-001-KCI
Page 3 of 5
Refer to www.keystonecerts.com to ascertain the ongoing status of this Certification Report. Approval of building products and/or materials can only be granted by
the building official having jurisdictional legal authority. Keystone Certifications, Inc. does not endorse or make warranties with respect to product performance or
suitability of a product for a given use.
9. Licensed Manufacturing Facilities
This Certification Report is applicable only to 5V Crimp
Panel non-structural through-fastened metal roof and
wall panels manufactured at the following locations:
1st Coast Metal Roofing Supply
186 State Rd 207
East Palatka, Florida 32131
Each licensed facility is subject to periodic inspection by
Keystone Certifications to verify conformance with
Keystone Roof Covering Certification & Listing Program
requirements.
10. Identification
5V Crimp Panel non-structural through-fastened metal
roof and wall panels represented by this report shall be
identified with Keystone Roof Covering Certification &
Listing Program certification labeling illustrated below,
to be applied to individual panels, packaging, invoicing or
bills of lading:
keystonecerts.com
KCI-11030-001
Aaron M. Shultz
Validation Manager
Metal Roof Certification & Listing Program
Certification Report
11030-001-KCI
Page 4 of 5
Refer to www.keystonecerts.com to ascertain the ongoing status of this Certification Report. Approval of building products and/or materials can only be granted by
the building official having jurisdictional legal authority. Keystone Certifications, Inc. does not endorse or make warranties with respect to product performance or
suitability of a product for a given use.
Appendix 1
Anchor Pattern A
Anchor Pattern B
Note: In all cases (new construction and re-roofing), the
anchors shall fully penetrate the OSB roof deck.
Metal Roof Certification & Listing Program
Certification Report
11030-001-KCI
145 Limekiln Road, Suite 100B Issue Date: 9/01/2017
New Cumberland, PA 17070 Revision Date: 1/11/2021
www.keystonecerts.com Expiration Date: 10/12/2025
Refer to www.keystonecerts.com to ascertain the ongoing status of this Certification Report. Approval of building products and/or materials can only be granted by
the building official having jurisdictional legal authority. Keystone Certifications, Inc. does not endorse or make warranties with respect to product performance or
suitability of a product for a given use.
Certificate Revisions
Rev # Date Description
0 9/1/2017 Initial issuance.
1 9/6/2017 Revised 2017 FBC Particleboard Section reference to 2301.1.8.
2 1/8/2018 Added reference to associated Florida Product Approval No FL24397.
3 1/23/2018 Added hyperlink to FL24397
4 6/25/2018 Removed ref’s to measurements for mat’l thickness and yield strength, relying on
applicable Gauge and steel Grade.
5 3/12/2019 Updated Model name to include metal roof "and wall panels"
6 10/7/2019 Updated ANSI Logo to proper requirements. Revised anchorage illustrations for
clarity, added reference to optional re-roofing / re-covering installation over “one
layer of existing shingles”.
7 10/12/2020 Updated to 2020 FBC 7th Edition.
8 1/11/2021 Corrected Model name. Updated FPA link.