Loading...
340 2nd ST RES21-0371 Revision - Energy Sheets signed 1-25-22_1RES21-0371 Revision Request/Correction to Comments City of Atlantic Beach Building Department 800 Seminole Rd, Atlantic Beach, FL 32233 **ALL INFORMATION HIGHLIGHTED IN GRAY IS REQUIRED. Phone: (904) 247-5826 Email: Building-Dept@coab.us PERMIT#: _______ _; D Revision to Issued Permit OR 12'.J Corrections to Comments Project Address: 3 W d /\.J S·tr:eGi Contractor/Contact Name: _s~·, 3.,-'f\"-'=-Q. +~. v_ .. _c"--_,_l~+. O'-'!V\---'-"'e.'-< _~___;:b:;....OJc......::..,(..,_l ~-'?f--'~'--='--\-'-,-f/'--....;.i<_e._x._W'-----'.i_\ l:J..; (f.='tf\..:::5:....__ ____ _ Contact Phone: '{ )If., 7 S'°l , i 8 Q Email: re:x.@ 5 i J hotves~\, CP"-" Description of Proposed Revision/ Corrections: 0 00 1_...R~e._)(...___...,.l_J_~ ~ll_,_I _"'-~""'~< _____ affirm the revision/correction to comments is inclusive of the proposed changes. (printed name) ~~I proposed revision/corrections add additional square footage to original submittal? 1£:JNo D Yes (additional s.f. to be added: ____________ ) •~I proposed revision~c_orrec:ions ad~ add'.ti~nal increase in b, 1ding value to original submittal? l)LJNo D*Yes (add1t1onal increase in building value: ;,-t----1'H-+-----~ (Contractor must sign if increase in valuation) (Office Use Only) D Approved D Denied D Not Applicable to Department Permit Fee Due$ _____ _ Revision/Plan Review Comments ____________________________ _ Department Review Required: Building Planning & Zoning Tree Administrator Public Works Public Utilities Public Safety Fire Services Reviewed By Date Updated 10/17/18 RES21-0371 FORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation -Residential Performance Method Project Name: Street: City, State, Zip: Owner: Design Location: Wade Residence 340 2nd Ave Atlantic Beach , FL , FL, MAYPORT_NS 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area above grade (ft') Conditioned floor area below grade (ft2) 7. Windows(795.0 sqft.) Description a. U-Factor: Dbl, U=0.40 SHGC: SHGC=0.25 b. U-Factor: N/A SHGC: c. U-Factor: N/A SHGC: New (From Plans) Detached 1 4 No 3944 0 Area 794.95 tt• ft2 fl' Area Weighted Average Overhang Depth: 6.029 ft. 0.250 Area Area Weighted Average SHGC: 8. Skylights C. U-Factor:(AVG) N/A SHGC(AVG): N/A 9. Floor Types (3944.0 sqfl.) Insulation Area a. Slab-On-Grade Edge Insulation R=0.0 2162.00 ft2 b. Floor Over Other Space R=0.0 960.00 tt2 c. other (see details) R= 822.00 tt2 Builder Name: Signature Homes & Development, Inc. Permit Office: Atlantic Beach Permit Number: Jurisdiction: 261100 County: Duval (Florida Climate Zone 2 ) 10. Wall Type~393.4 sqft.) a. Frame -Wood, Exterior b. Frame -Wood, Adjacent c. NIA d. N/A 11. Ceiling Types (2984.0 sqft.) a. Roof Deck (Unvented) b. NIA c. N/A 12. Ducts a. Sup: Attic, Rel: Attic, AH: 2nd Floor b. Sup: Attic, Ret: Attic, AH: 2nd Floor 13. Cooling systems a. Central Unit b. Central Unit 14. Heating systems a. Electric Heat Pump b. Electric Heat Pump 15. Hot water systems a. Propane Tankless b. Conservation features None 16. Credits Insulation Area R=19.0 4596.50 ft2 R=19.0 796.89 ft2 R= tt• R= tt2 Insulation Area R=20.0 2984.00 ft2 R= tt• R= ft2 R tt• 6 281.06 6 231.66 kB tu/hr Efficiency 26.3 SEER:15.25 26.3 SEER:15.25 kBtu/hr Efficiency 25.0 HSPF:9.50 25.0 HSPF:9.50 Cap: 1 gallons EF: 0.750 Pstat Glass/Floor Area: 0.202 Total Proposed Modified Loads: 97.86 PASS Total Baseline Loads: 114.47 I hereby certify that the plans and specifications covered by this calculation are in compliance with the Florida Energy Code. PREPARED BY: DATE: 6/20/2021 I hereby certify that this building, s designed, is in compliance with the Florida Energy Review of the plans and specifications covered by this calculation indicates compliance with the Florida Energy Code. Before construction is completed this building will be inspected for compliance with Section 553.908 Florida Statutes. BUILDING OFFICIAL: DATE: ________________ _ -Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACHS0 (R402.4.1.2). 6/20/2021 8:20 PM EnergyGauge® USA 7.0.00-FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 5 FORM R405-2020 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 85 The lower the EnergyPerformance Index, the more efficient the home. 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area (ft2) 7. Windows•• a. U-Factor: SHGC: b. U-Factor: SHGC: c. U-Factor: SHGC: d. U-Factor: SHGC: Description Dbl, U=0.40 SHGC=0.25 N/A NIA N/A Area Weighted Average Overhang Depth: Area Weighted Average SHGC: 8. Skylights Description a. U-Factor(AVG): N/A SHGC(AVG): N/A 9. Floor Types a. Slab-On-Grade Edge Insulation b. Floor Over Other Space c. other (see details) 340 2nd Ave, Atlantic Beach , FL, New (From Plans) Detached 4 No 3944 Area 794.95 ft2 11• ft• ft2 6.029 ft. 0.250 Area fl2 Insulation Area R=0.0 2162.00 ft2 R=0.O 960.00 ft2 R= 822.00 ft2 10. Wall Type and Insulation a. Frame -Wood, Exterior b. Frame -Wood, Adjacent c. NIA d. NIA 11. Ceiling Type and insulation level a. Roof Deck (Unvented) b. N/A c. NIA 12. Ducts, location & insulation level a. Sup: Attic, Rel: Attic, AH: 2nd Floor b. Sup: Attic, Ret: Attic, AH: 2nd Floor 13. Cooling systems a. Central Unit b. Central Unit 14. Heating systems a. Electric Heat Pump b. Electric Heat Pump 15. Hot water systems a. Propane b. Conservation features None Credits (Performance method) I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. th~rwise, a new EPL Display Card will be completed based on installed Code complian a i(es. Builder Signature: Date: 1;;./2s/2.1 I I ~d~tf0~_2_1'-J~st ........ ____ City/FL Zip: AB fl 3))33 Address of New Ho ----- Insulation Area R=19.0 4596.50 ft2 R=19.0 796.89 ft2 R= ft2 R= ft2 Insulation Area R=20.0 2984.00 ft2 R= ft2 R= ft• R ft2 6 281.06 6 231.66 kBtu/hr Efficiency 26.3 SEER:15.25 26.3 SEER:15.25 kBtu/hr Efficiency 25.0 HSPF:9.50 25.0 HSPF:9.50 Cap: 1 gallons EF: 0.75 Pstat *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff . ... Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 6/20/2021 8:20 PM EnergyGauge® USA 7.0.00 • FlaRes2020 FBC 7th Edition (2020) Compliant Software Pace 1 of 1