Loading...
812 Ocean Blvd RES21-0158 5th submittal 5 of 7 TFSystemSpecificationsandTestData_1TF System£ Specification Data PRODUCT NAME TF System®-- The Vertical Insulated Concrete Form MANUFACTURER TF System® Wisconsin Thermo-Form, Inc. 185 East Walnut Street Sturgeon Bay, WI 54235 USA Web: www.tfsystem.com Phone: 800-3600-4634 or 920-746-9100 Fax: 920-746-9975 E-mail: info@tfsystem.com PRODUCT DESCRIPTION TF System® is an insulated concrete forming system consisting of expanded polystyrene panels (EPS) held in place by structural vertical I-beams. When filled with concrete this results in full width, monolithic concrete walls of exceptional strength and energy efficiency. The I-beam substructure also serves as a convenient and predictable attachment point for both interior and exterior wall treatments. APPLICATION STANDARDS TF System® walls are subject to ACI (American Concrete Institute) Chapter 318 (latest revision), which indicates reinforcement requirements for standard poured walls. Because TF System ® forms are NOT waffle grid or post and beam design, no additional engineering is required except for cases where ACI 318 calls for engineering of specific applications. Essentially, TF System ® walls are conventional poured walls with the insulation applied before, rather than after, the pour. DIMENSIONS EPS Panels Width 12-inches Height Variable up to 12 feet Thickness 2.5-inches standard (3.0, 3.5, 4.0-inches optional) I-Beams (steel) Flange Width 3-inches Height Variable up to 12 feet Thickness 4, 6, 8, 10, 12, 14, 16, 18, 20, 24–inches (nominal concrete wall width) I-Beams (PVC) Flange Width 2-inches Height Variable up to 12 feet Thickness 4, 6, 8, 10–inches (nominal concrete wall width) PHYSICAL PROPERTIES Steel I-beams Content Galvanized sheet metal Thickness 0.17 – 0.20 doubled Shaping Method Roll forming Fastening Method Norlock Technologies double clinch Screw Pullout Test # 6 235 lbs. # 8 277 lbs. # 10 307 lbs. TF System - The Vertical ICF, Inc. 3030C Holmgren Way Green Bay, WI 54304 Phone: 800-360-4634 or 920-983-9960 Fax: 920-983-9962 Email: info@tfsystem.com 8-inches PVC I-beams Content Recycled PVC Thickness 0.125 Shaping Method Extruded Expanded Polystyrene Polystyrene insulation used in TF System® is approved by applicable code enforcement agencies. See physical properties table: Density (minimum) 1.95 lbs. per cubic foot Compressive Strength 25 psi @ 10% deformation Flexural Strength 55 psi Dimensional Tolerance  0.030 inch/ft. length  1/16-inch width  1/16-inch thickness Thermal Resistance (minimum per inch) 4.2 @ 75° F 4.6 @ 40° F Oxygen Index (minimum) 24.0 Flame Spread 20 as tested per ASTM E84 Smoke Density 150-300 as tested per ASTM E84 Applicable Code Listings ICBO PFC568C, SBCCI PST & ESI Report No. 94136D; ICC Evaluation Service, Inc. ESR-1006 Labeling UL Virgin Certified material (no recycled content) Termite Resistant Treatment (optional) PerformGuard® borate treatment (PerformGuard® is a registered trademark of AFM® Corp.) Resins Permitted Specified by Wisconsin Thermo-Form, Inc. SOUND TRANSMISSION TF System® 6-inch concrete wall, uncovered 42 dB STC TF System® 6-inch concrete wall, with 5/8 drywall on both sides 55 dB STC FIRE RATING Concrete walls have a 2 - 4 hour fire rating depending upon concrete thickness. AVAILABILITY International, contact manufacturer for local TF System® representative. COST Insulated concrete forms are very cost competitive. TF System® walls provide comparable R-value to conventional poured concrete wall assemblies with 2x6 stud framing, six-inches of fiberglass batt-insulation, and one-inch of exterior sheathed insulation. Contractors find the speed of installation provides labor cost savings. Building owners continually appreciate lower life cycle costs, including lower utility bills, reduced insurance premiums, and higher resale value. WARRANTY Refer to Terms and Conditions of Sale Document available from manufacturer. MAINTENANCE Maintenance of TF System®, installed per manufacturers instructions, is not required. TECHNICAL SERVICES TF System® Installation Manual, available by request or at www.tfsytem.com Telephone Support, 800-360-4634 or 920-746-9100 Jobsite Training, contact manufacturer for availability and rates ADDITIONAL INFORMATION www.tfsystem.com 1.35 lbs. per cubic foot 15 45 4.17 @ 75 Deg F 4.55 @ 40 Deg F 4.76 @ 25 Deg F Specified by TF System - The Vetical ICF, Inc. 920-908-9960 RICE ENGINEERING Rice Engineering - 105 School Creek Trail - Luxemburg, WI 54217 Phone:(920) 845-1042 Fax:(920) 845-1048 Email: daverice@rice-inc.com April 13, 2009 RE: T/F Systems Vertical ICF To Whom It May Concern: The T/F system for insulated concrete forms is in essence, a concrete form which stays in place after construction. During construction, the expanded polystyrene panels (EPS) serve as the main form, and the “I Beams” hold the EPS panels in place until the concrete has hardened. In the completed wall, the concrete forms are not a structural component, As such, the wall should be designed using its actual concrete thickness in accordance with ACI 318, the local building code, or other approved methods. The Forms do serve two other purposes in the completed wall, both as insulation, and as an attachment method for finish materials. Both the EPS panels, and the I-Beams have been tested by a third party testing agency for burn rate, and ignition temperature for compliance with chapter 26 of the international building code. The I-beams have also been tested for their tensile properties, for screw withdrawal, and screw shear. The test results show that with a safety factor of 4, the tensile capacity is 144 #, and the shear capacity is 113# using # 10 screws. The evaluation reports have been included as an attachment for your reference. Please feel free to call with any questions. Benjamin T. Gerold, P.E. Bradley J. Kuehl, P.E. TF System£ Technical Bulletin 12003-1 TF System£ Code Compliance There are three unique types of Insulated Concrete Forming systems currently available in the marketplace. They are the waffle-grid, post and beam, and straight wall designs. The post and beam and waffle-grid systems are designed to reduce the amount of concrete used in a particular wall cavity and as such need to have special code approval or be specifically engineered to ensure correct reinforcement requirements. Straight wall systems are designed to provide a wall that is of the same dimension and cross section as conventionally formed concrete walls. TF System£ is a straight wall form that was designed to closely mimic conventional plywood, steel, or aluminum forms. As such, TF System£ does not require a separate evaluation report. TF System£ is a straight wall type form that results in a full width, monolithic poured concrete wall and is therefore subject to American Concrete Institute 318-02, which spells out reinforcement requirements for poured concrete walls. In addition to ACI 318- 02, local codes must be followed as well. Reinforcement within a TF System £ wall is exactly the same as conventionally formed concrete walls of the same dimension. Concrete exerts a significant amount of pressure as it is poured into formwork and until it acquires the strength to support itself. In this regard, TF System£ has been field and laboratory tested to determine the strength of its individual components. TF System £ crossties were determined to have a tension value of 850 pounds. The EPS planks (2.5 inches thick, 1.95 lbs/cu. ft. density) have a capacity of 525 psf. Using these figures, we recommend a pour rate of four feet per hour in conjunction with adequate bracing (as shown in our TF System£ Installation Manual). Consolidation of the poured concrete inside the form system is acceptable if done in a proper manner. The expanded polystyrene component of TF System£ is fully code approved and meets all flame spread and smoke development ratings. TF System£ Technical Bulletin 12003-2 TF System£ Fastener Pullout Testing In many applications TF System£ walls will be covered with a variety of treatments including, but not limited to, drywall, vinyl siding, wood siding, fiber cement siding, paneling, and brick or stone veneer. These treatments will need to be attached to the walls by means of installing screws through the treatment (or in the case of brick and stone through the wall ties) and into metal flange of the TF System £ I-Beam. TF System£ I-Beams were subjected to screw pullout testing and the following average results were achieved: 1. Self-tapping steel fasteners #6 235 lbs. #8 277 lbs. #10 307 lbs. 2. Sharp point light metal/wood screws #8 286 lbs. #10 313 lbs. Always follow manufacturers recommendations or accepted construction practices to determine pattern and frequency of fasteners. Use corrosion resistant fasteners in applications exposed to the elements. TF System£ Technical Bulletin 12003-3 TF System£ Sound Transmission Characteristics Above grade residential, multi family, and, in many instances, commercial structures need to be designed to achieve a certain level of sound attenuation. Insulated concrete walls naturally provide a high level of sound control. This sound control ability is measured in STC (Sound Transmission Classification), and is determined through testing room sized wall section in an approved sound testing laboratory. A TF System£ wall section was tested on September 8th, 1999 at Riverbank Laboratory in Geneva, Illinois. This wall section had a 6-inch concrete core with five/eighths inch thick drywall screw attached to both sides. An STC of 55 was established for this particular wall. This level of sound control is considered to be an excellent rating for most applications. In all cases where specific STC levels are required, it is the responsibility of the project design team to determine the components necessary to achieve these levels. TECHDATA TM WWW.FOAM-CONTROL.COM Foam-Control EPS has a flame spread index of 20 and a smoke developed index of 150-300 when tested in accordance with ASTM E84/UL 723 for densities from 0.7 - 2.0 lb/ft3. Please refer to Foam-Control EPS UL certificates. 1 See ASTM C578 Standard for test methods and complete information. Foam-Control EPS Properties Property ASTM C578 Type XI Type I Type VIII Type II Type IX Type XIV Type XV Nominal Density lb/ft3 (kg/m3) 0.75 (12) 1.00 (16) 1.25 (20) 1.50 (24) 2.00 (32) 2.50 (40) 3.00 (48) Density1, min. lb/ft3 (kg/m3)0.70(12)0.90(15)1.15(18)1.35(22)1.80(29)2.40(38)2.85(46) Design Thermal Resistance per 1.0 in. thickness 25oF oF.ft2.h/Btu (oK.m2/W)3.60(0.63) 4.35 (0.77) 4.55 (0.80) 4.76 (0.84) 5.00 (0.88) 5.00 (0.89) 5.10 (0.90) 40oF oF.ft2.h/Btu (oK.m2/W) 3.43 (0.60) 4.17 (0.73) 4.25 (0.75) 4.55 (0.80) 4.76 (0.84) 4.76 (0.84) 4.85 (0.85) 75oF oF.ft2.h/Btu (oK.m2/W) 3.22 (0.57) 3.85 (0.68) 3.92 (0.69) 4.17 (0.73) 4.35 (0.77) 4.35 (0.77) 4.45 (0.78) Thermal Resistance1, min per 1.0 in. thickness 25oF oF.ft2.h/Btu (oK.m2/W) 3.45 (0.61) 4.20 (0.74) 4.40 (0.77) 4.60 (0.85) 4.80 (0.84) 4.80 (0.84) 4.90 (0.86) 40oF oF.ft2.h/Btu (oK.m2/W) 3.30 (0.58) 4.00 (0.70) 4.20 (0.74) 4.40 (0.77) 4.60 (0.81) 4.60 (0.81) 4.70 (0.83) 75oF oF.ft2.h/Btu (oK.m2/W) 3.10 (0.55) 3.60 (0.63) 3.80 (0.67) 4.00 (0.70) 4.20 (0.74) 4.20 (0.74) 4.30 (0.76) Compressive Strength1 @ 10% deformation, min.psi(kPa)5.0(35)10.0(69)13.0(90)15.0(104)25.0(173)40.0(276)60.0(414) Flexural Strength1, min.psi(kPa)10.0(69)25.0(173)30.0(208)35.0(242)50.0(345)60.0(414)75.0(517) Water Vapor Permeance1 of 1.0 in. thickness, max., perm 5.0 5.0 3.5 3.5 2.5 2.5 2.5 Water Absorption1 by total immersion, max., volume %4.0 4.0 3.0 3.0 2.0 2.0 2.0 Foam-ControlTM EPS (expanded polystyrene) rigid board foam plastic is for all types of industrial, packaging, and construction uses. Foam-Control EPS is manufactured in conformance with numerous standards. • ASTM C 578 (Thermal Insulation) • ASTM E 2430 (EIFS boards) • ICC ES AC12 (Foam Plastic Insulation) TM Foam-Control EPS products are manufac- tured by AFM Corporation licensees. Copyright ©2007 AFM Corporation. All rights reserved. Printed in USA. Foam-Control and Perform Guard are trademarks of AFM Corporation, Burnsville, MN. ICC ES logo is a registered trademark of ICC Evaluation Service, Inc. UL logo is a registered trademark of Underwriters Laboratories Inc. FM logo is a registered trademark of Factory Mutual/FM Global. FC02-04/07 CONTROL, NOT COMPROMISE. Foam-Control EPS (800) 255-0176 General Information (800) 255-3908 Technical Information www.foam-control.com TM Design Options. Cost effective design is among the highest priori- ties for industrial, packaging, and construction appli- cations. Foam-Control EPS products are available in a range of Types necessary to provide control of struc- tural integrity, thermal resistance (R-value), and cost effectiveness. Thermal Performance. The R-value of Foam-Control EPS remains constant and does not suffer from R-value loss. The closed cell structure of Foam-Control EPS contains air and not blowing agents which deplete over time. Exposure to Water and Water Vapor. The mechanical properties of EPS are unaffected by mois- ture. Exposure to water or water vapor does not cause swelling. Temperature Exposure/Flame Retardants. EPS is able to withstand the rigors of temperature cycling, assuring long-term performance. Although flame retardants used in the manufacture of EPS provide an important margin of safety, all EPS products must be considered combustible. The maximum recommended long-term exposure tempera- ture for Foam-Control EPS is 1650F (740C). Adhesives, Coatings, and Chemicals. Solvents which attack EPS include esters, ketones, ethers, aromatic, and aliphatic hydrocarbons and their emulsions, among others. If EPS is to be placed in contact with mate- rials (or their vapors) of unknown composition, pretest for compatibility at maximum exposure temperature. Do not install or use EPS with coal tar pitch, highly solvent- extended mastics, or solvent-based adhesives without adequate separation. Quality Assurance/Building Code Compliance. Foam-Control EPS meets or exceeds the requirements of ASTM C578, “Standard Speci- fication for Rigid, Cellular Polystyrene Thermal Insulation.” Foam-Control EPS is monitored for Quality Control and Listed by Underwriters Laboratories Inc. The International Code Council Evaluation Service recognizes Foam-Control EPS for building code compliance. Please see ICC ES ESR-1006. Note: Local Building Codes must be followed regarding thermal barriers. Resistance to Termites, Mold, and Mildew. Foam plastic insulations have been shown to become termite infested under certain exposure conditions. Foam-Control EPS with Perform Guard® provides resistance to termite infestation. Please review literature on Foam-Control EPS with Perform Guard for complete information. EPS will not decompose and will not support mold or mildew growth. EPS provides no nutrient value to plants or animals. Weathering. Long-term exposure to sunlight causes yellowing and a slight embrittlement of the surface due to ultraviolet light. This has little effect on mechanical properties. If stored out- doors, cover EPS with opaque polyethylene film, tarps, or similar material. Warranty. Foam-Control EPS Licensees offer a product warranty ensuring thermal performance, physical properties, and termite resistance. TECHDATA TM WWW.FOAM-CONTROL.COM Foam-Control EPS has a flame spread index of 20 and a smoke developed index of 150-300 when tested in accordance with ASTM E84/UL 723 for densities from 0.7 - 2.0 lb/ft3. Please refer to Foam-Control EPS UL certificates. 1 See ASTM C578 Standard for test methods and complete information. Foam-Control EPS Properties Property ASTM C578 Type XI Type I Type VIII Type II Type IX Type XIV Type XV Nominal Density lb/ft3 (kg/m3) 0.75 (12) 1.00 (16) 1.25 (20) 1.50 (24) 2.00 (32) 2.50 (40) 3.00 (48) Density1, min. lb/ft3 (kg/m3)0.70(12)0.90(15)1.15(18)1.35(22)1.80(29)2.40(38)2.85(46) Design Thermal Resistance per 1.0 in. thickness 25oF oF.ft2.h/Btu (oK.m2/W)3.60(0.63) 4.35 (0.77) 4.55 (0.80) 4.76 (0.84) 5.00 (0.88) 5.00 (0.89) 5.10 (0.90) 40oF oF.ft2.h/Btu (oK.m2/W) 3.43 (0.60) 4.17 (0.73) 4.25 (0.75) 4.55 (0.80) 4.76 (0.84) 4.76 (0.84) 4.85 (0.85) 75oF oF.ft2.h/Btu (oK.m2/W) 3.22 (0.57) 3.85 (0.68) 3.92 (0.69) 4.17 (0.73) 4.35 (0.77) 4.35 (0.77) 4.45 (0.78) Thermal Resistance1, min per 1.0 in. thickness 25oF oF.ft2.h/Btu (oK.m2/W) 3.45 (0.61) 4.20 (0.74) 4.40 (0.77) 4.60 (0.85) 4.80 (0.84) 4.80 (0.84) 4.90 (0.86) 40oF oF.ft2.h/Btu (oK.m2/W) 3.30 (0.58) 4.00 (0.70) 4.20 (0.74) 4.40 (0.77) 4.60 (0.81) 4.60 (0.81) 4.70 (0.83) 75oF oF.ft2.h/Btu (oK.m2/W) 3.10 (0.55) 3.60 (0.63) 3.80 (0.67) 4.00 (0.70) 4.20 (0.74) 4.20 (0.74) 4.30 (0.76) Compressive Strength1 @ 10% deformation, min.psi(kPa)5.0(35)10.0(69)13.0(90)15.0(104)25.0(173)40.0(276)60.0(414) Flexural Strength1, min.psi(kPa)10.0(69)25.0(173)30.0(208)35.0(242)50.0(345)60.0(414)75.0(517) Water Vapor Permeance1 of 1.0 in. thickness, max., perm 5.0 5.0 3.5 3.5 2.5 2.5 2.5 Water Absorption1 by total immersion, max., volume %4.0 4.0 3.0 3.0 2.0 2.0 2.0 Foam-ControlTM EPS (expanded polystyrene) rigid board foam plastic is for all types of industrial, packaging, and construction uses. Foam-Control EPS is manufactured in conformance with numerous standards. • ASTM C 578 (Thermal Insulation) • ASTM E 2430 (EIFS boards) • ICC ES AC12 (Foam Plastic Insulation) TM Foam-Control EPS products are manufac- tured by AFM Corporation licensees. Copyright ©2007 AFM Corporation. All rights reserved. Printed in USA. Foam-Control and Perform Guard are trademarks of AFM Corporation, Burnsville, MN. ICC ES logo is a registered trademark of ICC Evaluation Service, Inc. UL logo is a registered trademark of Underwriters Laboratories Inc. FM logo is a registered trademark of Factory Mutual/FM Global. FC02-04/07 CONTROL, NOT COMPROMISE. Foam-Control EPS (800) 255-0176 General Information (800) 255-3908 Technical Information www.foam-control.com TM Design Options. Cost effective design is among the highest priori- ties for industrial, packaging, and construction appli- cations. Foam-Control EPS products are available in a range of Types necessary to provide control of struc- tural integrity, thermal resistance (R-value), and cost effectiveness. Thermal Performance. The R-value of Foam-Control EPS remains constant and does not suffer from R-value loss. The closed cell structure of Foam-Control EPS contains air and not blowing agents which deplete over time. Exposure to Water and Water Vapor. The mechanical properties of EPS are unaffected by mois- ture. Exposure to water or water vapor does not cause swelling. Temperature Exposure/Flame Retardants. EPS is able to withstand the rigors of temperature cycling, assuring long-term performance. Although flame retardants used in the manufacture of EPS provide an important margin of safety, all EPS products must be considered combustible. The maximum recommended long-term exposure tempera- ture for Foam-Control EPS is 1650F (740C). Adhesives, Coatings, and Chemicals. Solvents which attack EPS include esters, ketones, ethers, aromatic, and aliphatic hydrocarbons and their emulsions, among others. If EPS is to be placed in contact with mate- rials (or their vapors) of unknown composition, pretest for compatibility at maximum exposure temperature. Do not install or use EPS with coal tar pitch, highly solvent- extended mastics, or solvent-based adhesives without adequate separation. Quality Assurance/Building Code Compliance. Foam-Control EPS meets or exceeds the requirements of ASTM C578, “Standard Speci- fication for Rigid, Cellular Polystyrene Thermal Insulation.” Foam-Control EPS is monitored for Quality Control and Listed by Underwriters Laboratories Inc. The International Code Council Evaluation Service recognizes Foam-Control EPS for building code compliance. Please see ICC ES ESR-1006. Note: Local Building Codes must be followed regarding thermal barriers. Resistance to Termites, Mold, and Mildew. Foam plastic insulations have been shown to become termite infested under certain exposure conditions. Foam-Control EPS with Perform Guard® provides resistance to termite infestation. Please review literature on Foam-Control EPS with Perform Guard for complete information. EPS will not decompose and will not support mold or mildew growth. EPS provides no nutrient value to plants or animals. Weathering. Long-term exposure to sunlight causes yellowing and a slight embrittlement of the surface due to ultraviolet light. This has little effect on mechanical properties. If stored out- doors, cover EPS with opaque polyethylene film, tarps, or similar material. Warranty. Foam-Control EPS Licensees offer a product warranty ensuring thermal performance, physical properties, and termite resistance. Page 7 of 15 ESR-1006 TABLE 1 PROPERTY TYPE I TYPE VIII TYPE II TYPE IX Density, min., lb/ft3 (kg/m3) 0.90 (15) 1.15 (18) 1.35 (22) 1.80 (29) Thermal Resistance, min., per 1.0 in. thickness 75/F.-ft2-h/Btu (/K-m2/W) 3.60 (0.63) 3.80 (0.67) 4.00 (0.70) 4.20 (0.74) Compressive strength @ 10% def., min. psi (kPa) 10.0 (69) 13.0 (90) 15.0 (104) 25.0 (17.3) Flexural strength min., psi (kPa) 25.0 (173) 30.0 (208) 40.0 (276) 50.0 (345) Water vapor permeance of 1.0 in. thickness max., perm 5.0 3.5 3.5 2.0 Water absorption by total immersion, max., volume % 4.0 3.0 3.0 2.0 CONTACTCONTACTCONTACTCONTACTCONTACT: AFM R-Control Building Systems 211 River Ridge Circle #102 Burnsville, MN 55337 952/474-0809 HAZARD RATING:2=Moderate 0=Minimal 3=Serious 1=Slight 4=Severe HEALTH 0 FIRE 2 REACTIVITY 0 PRODUCTPRODUCTPRODUCTPRODUCTPRODUCT: R-Control®l EPS, Contour Taper Tile®, Perform®, WSG®, Fabri-tech®, SpecLam™ core, R-Control® SIP core and Geofoam SYNONYMSSYNONYMSSYNONYMSSYNONYMSSYNONYMS: AFM Expanded Polystyrene (EPS) PRODUCT GRADESPRODUCT GRADESPRODUCT GRADESPRODUCT GRADESPRODUCT GRADES: Type I, VIII, II and IX CHEMICAL FAMILYCHEMICAL FAMILYCHEMICAL FAMILYCHEMICAL FAMILYCHEMICAL FAMILY: Polystyrene Thermoplastic CAS REGISTRY NOCAS REGISTRY NOCAS REGISTRY NOCAS REGISTRY NOCAS REGISTRY NO: 9003536 CAS NAMECAS NAMECAS NAMECAS NAMECAS NAME: Ethenylbenzene Homopolymer FORMULAFORMULAFORMULAFORMULAFORMULA: (C8 H8)nTSCA INVENTORY STATUS: TSCA INVENTORY STATUS: TSCA INVENTORY STATUS: TSCA INVENTORY STATUS: TSCA INVENTORY STATUS: Listed I - PRODUCT INFORMATIONI - PRODUCT INFORMATIONI - PRODUCT INFORMATIONI - PRODUCT INFORMATIONI - PRODUCT INFORMATION HAZARDOUS COMPONENTSHAZARDOUS COMPONENTSHAZARDOUS COMPONENTSHAZARDOUS COMPONENTSHAZARDOUS COMPONENTS:CAS REGISTRY NOCAS REGISTRY NOCAS REGISTRY NOCAS REGISTRY NOCAS REGISTRY NO:APPROX. WEIGHT PERCENTAGEAPPROX. WEIGHT PERCENTAGEAPPROX. WEIGHT PERCENTAGEAPPROX. WEIGHT PERCENTAGEAPPROX. WEIGHT PERCENTAGE: Pentane 109660 1% Max. Halogen Flame Retardants N/A .9% Max. NON-HAZARDOUS COMPONENTSNON-HAZARDOUS COMPONENTSNON-HAZARDOUS COMPONENTSNON-HAZARDOUS COMPONENTSNON-HAZARDOUS COMPONENTS:CAS REGISTRY NOCAS REGISTRY NOCAS REGISTRY NOCAS REGISTRY NOCAS REGISTRY NO:APPROX. WEIGHT PERCENTAGEAPPROX. WEIGHT PERCENTAGEAPPROX. WEIGHT PERCENTAGEAPPROX. WEIGHT PERCENTAGEAPPROX. WEIGHT PERCENTAGE: Polystyrene 9003536 98% Min. II - INGREDIENTSII - INGREDIENTSII - INGREDIENTSII - INGREDIENTSII - INGREDIENTS III - PHYSICAL DATAIII - PHYSICAL DATAIII - PHYSICAL DATAIII - PHYSICAL DATAIII - PHYSICAL DATA FORM: FORM: FORM: FORM: FORM: Rigid cellular foam blocks, boards, and shapes COLOR: COLOR: COLOR: COLOR: COLOR: White ODOR: ODOR: ODOR: ODOR: ODOR: Very slight hydrocarbon odor BOILING POINT: BOILING POINT: BOILING POINT: BOILING POINT: BOILING POINT: N/A MELTING POINT: MELTING POINT: MELTING POINT: MELTING POINT: MELTING POINT: Softens at 175o F. to 220o F. SPECIFIC GRAVITY (Water = 1): SPECIFIC GRAVITY (Water = 1): SPECIFIC GRAVITY (Water = 1): SPECIFIC GRAVITY (Water = 1): SPECIFIC GRAVITY (Water = 1): Density 0.6 pcf to 2.0 pcf VAPOR PRESSURE:VAPOR PRESSURE:VAPOR PRESSURE:VAPOR PRESSURE:VAPOR PRESSURE: N/A VOLATILES BY VOLUME: VOLATILES BY VOLUME: VOLATILES BY VOLUME: VOLATILES BY VOLUME: VOLATILES BY VOLUME: < 4% (pentane and water) VAPOR DENSITY (Air = 1): VAPOR DENSITY (Air = 1): VAPOR DENSITY (Air = 1): VAPOR DENSITY (Air = 1): VAPOR DENSITY (Air = 1): N/A EVAPORATION RATE: EVAPORATION RATE: EVAPORATION RATE: EVAPORATION RATE: EVAPORATION RATE: None SOLUBILITY IN WATER: SOLUBILITY IN WATER: SOLUBILITY IN WATER: SOLUBILITY IN WATER: SOLUBILITY IN WATER: Insoluble IV - FIRE & EXPLOSION DATAIV - FIRE & EXPLOSION DATAIV - FIRE & EXPLOSION DATAIV - FIRE & EXPLOSION DATAIV - FIRE & EXPLOSION DATA FLASH PT., AND METHOD USED: FLASH PT., AND METHOD USED: FLASH PT., AND METHOD USED: FLASH PT., AND METHOD USED: FLASH PT., AND METHOD USED: 610o F. Min. (ASTM D 1929) SPECIAL FIRE FIGHTING INSTRUCTIONS: SPECIAL FIRE FIGHTING INSTRUCTIONS: SPECIAL FIRE FIGHTING INSTRUCTIONS: SPECIAL FIRE FIGHTING INSTRUCTIONS: SPECIAL FIRE FIGHTING INSTRUCTIONS: Use approved self-contained breathing apparatus respirator and personal protective clothing (Turn out gear). EXTINQUISHING MEDIA:EXTINQUISHING MEDIA:EXTINQUISHING MEDIA:EXTINQUISHING MEDIA:EXTINQUISHING MEDIA: Water fog, carbon dioxide, dry chemical, foam. V - REACTIVITY DATAV - REACTIVITY DATAV - REACTIVITY DATAV - REACTIVITY DATAV - REACTIVITY DATA STABILITY (CONDITIONS TO AVOID):STABILITY (CONDITIONS TO AVOID):STABILITY (CONDITIONS TO AVOID):STABILITY (CONDITIONS TO AVOID):STABILITY (CONDITIONS TO AVOID): Stable. Avoid fire and high temperatures. INCOMPATIBILITY (MATERIALS TO AVOID):INCOMPATIBILITY (MATERIALS TO AVOID):INCOMPATIBILITY (MATERIALS TO AVOID):INCOMPATIBILITY (MATERIALS TO AVOID):INCOMPATIBILITY (MATERIALS TO AVOID): Will disolve in most organic solvents, and some insecticides, aldehydes, HAZARDOUS DECOMPOSITION: HAZARDOUS DECOMPOSITION: HAZARDOUS DECOMPOSITION: HAZARDOUS DECOMPOSITION: HAZARDOUS DECOMPOSITION: Carbon monoxide, carbon dioxide, carbon, water, hydrogen halide. HAZARDOUS POLYMERIZATION:HAZARDOUS POLYMERIZATION:HAZARDOUS POLYMERIZATION:HAZARDOUS POLYMERIZATION:HAZARDOUS POLYMERIZATION: None and amines. AUTOIGNITION TEMPERATURE:AUTOIGNITION TEMPERATURE:AUTOIGNITION TEMPERATURE:AUTOIGNITION TEMPERATURE:AUTOIGNITION TEMPERATURE: 850o F. Min. UNUSUAL FIRE AND EXPLOSION HAZARDS:UNUSUAL FIRE AND EXPLOSION HAZARDS:UNUSUAL FIRE AND EXPLOSION HAZARDS:UNUSUAL FIRE AND EXPLOSION HAZARDS:UNUSUAL FIRE AND EXPLOSION HAZARDS: May produce carbon monoxide, carbon dioxide, and water. Dust generated by fabrication, i.e., sanding, sawing, etc., will increase fire hazard and should be handled accordingly. dense black smoke. Smoke consists of carbon (soot) MAMAMAMAMATERIAL SAFETTERIAL SAFETTERIAL SAFETTERIAL SAFETTERIAL SAFETY DY DY DY DY DAAAAATTTTTA SHEETA SHEETA SHEETA SHEETA SHEET VI - HEALTH HAZARDS & FIRST AIDVI - HEALTH HAZARDS & FIRST AIDVI - HEALTH HAZARDS & FIRST AIDVI - HEALTH HAZARDS & FIRST AIDVI - HEALTH HAZARDS & FIRST AID PRINCIPAL HEALTH HAZARDS & SIGNS & SYMPTOMSPRINCIPAL HEALTH HAZARDS & SIGNS & SYMPTOMSPRINCIPAL HEALTH HAZARDS & SIGNS & SYMPTOMSPRINCIPAL HEALTH HAZARDS & SIGNS & SYMPTOMSPRINCIPAL HEALTH HAZARDS & SIGNS & SYMPTOMS OF EXPOSUREOF EXPOSUREOF EXPOSUREOF EXPOSUREOF EXPOSURE EYE CONTACT: EYE CONTACT: EYE CONTACT: EYE CONTACT: EYE CONTACT: Dust or particles may cause mechanical eye irritation and/or injury. INHALATION: INHALATION: INHALATION: INHALATION: INHALATION: Dust from mechanical fabrication may cause upper respiratory irritation. Fumes from hot wire cutting can also cause upper respiratory irritation. SKIN CONTACT: SKIN CONTACT: SKIN CONTACT: SKIN CONTACT: SKIN CONTACT: None. May produce slight skin irritation in a few individuals. INGESTION: INGESTION: INGESTION: INGESTION: INGESTION: Biologically inert. May act as an obstruction if swallowed. CARCINOGENICITY:CARCINOGENICITY:CARCINOGENICITY:CARCINOGENICITY:CARCINOGENICITY: None SAFETY PRECAUTIONS: SAFETY PRECAUTIONS: SAFETY PRECAUTIONS: SAFETY PRECAUTIONS: SAFETY PRECAUTIONS: Use positive ventilation. Mechanical fabrication, sanding, etc., requires the use of safety glasses or goggles and dust mask. VII - EMPLOYEE PROTECTIONVII - EMPLOYEE PROTECTIONVII - EMPLOYEE PROTECTIONVII - EMPLOYEE PROTECTIONVII - EMPLOYEE PROTECTION PERSONAL PROTECTIVE EQUIPMENT:PERSONAL PROTECTIVE EQUIPMENT:PERSONAL PROTECTIVE EQUIPMENT:PERSONAL PROTECTIVE EQUIPMENT:PERSONAL PROTECTIVE EQUIPMENT: RESPIRATORY PROTECTION:RESPIRATORY PROTECTION:RESPIRATORY PROTECTION:RESPIRATORY PROTECTION:RESPIRATORY PROTECTION: Use approved dust mask when sawing or sanding. SKIN PROTECTION: SKIN PROTECTION: SKIN PROTECTION: SKIN PROTECTION: SKIN PROTECTION: None required. Wear gloves and/or sleeves, if sensitivity noted. EYE PROTECTION: EYE PROTECTION: EYE PROTECTION: EYE PROTECTION: EYE PROTECTION: Use approved safety glasses/goggles when sawing or sanding. GENERAL CONTROL MEASURES:GENERAL CONTROL MEASURES:GENERAL CONTROL MEASURES:GENERAL CONTROL MEASURES:GENERAL CONTROL MEASURES: Use positive ventilation. VIII - SPILL OR LEAK PROCEDURESVIII - SPILL OR LEAK PROCEDURESVIII - SPILL OR LEAK PROCEDURESVIII - SPILL OR LEAK PROCEDURESVIII - SPILL OR LEAK PROCEDURES IX - SPECIAL PRECAUTIONSIX - SPECIAL PRECAUTIONSIX - SPECIAL PRECAUTIONSIX - SPECIAL PRECAUTIONSIX - SPECIAL PRECAUTIONS TRANSPORTATION REQUIREMENTS: TRANSPORTATION REQUIREMENTS: TRANSPORTATION REQUIREMENTS: TRANSPORTATION REQUIREMENTS: TRANSPORTATION REQUIREMENTS: Not a D.O.T. "Hazardous Material." STORAGE AND HANDLING: STORAGE AND HANDLING: STORAGE AND HANDLING: STORAGE AND HANDLING: STORAGE AND HANDLING: Expanded Polystyrene, although it contains a fire retardant additive, is considered to be combustible and adequate protection from sources of ignition should be taken. The information contained herein is provided as a general reference. AFM Corporation believes the data set forth herein is accurate and is given in good faith. AFM Corporation makes no guarantee or warranty and does not assume any liability with respect to the accuracy or completeness of such information. AFM® EPS, Contour Taper Tile®, Perform®, WSG® EPS, Fabri-tech®, SpecLam™, R-Control®, and Perform Guard® are trademarks of AFM Corp. Copyright by:AFM R-Control P.O. Box 530 24000 W. Highway 7, Suite. 201 Excelsior, MN 55331 (952) 474-0809 EPS - MSDS 07/01 FIRST AIDFIRST AIDFIRST AIDFIRST AIDFIRST AID EYES: EYES: EYES: EYES: EYES: Rinse with clean water. Remove foreign particles with clean, lint-free cloth. Obtain medical attention if pain, blinking, tears, or redness persist. INHALATION: INHALATION: INHALATION: INHALATION: INHALATION: If overcome by exposure, move to fresh air. Provide oxygen and artificial respiration. Get medical attention. SKIN: SKIN: SKIN: SKIN: SKIN: Not expected to present skin hazard. Wash exposed areas with mild soap and water. Consult physician if irritation persists. INGESTION: INGESTION: INGESTION: INGESTION: INGESTION: Not expected to present significant ingestion hazard. Consult physician if swallowed. Wear safety glasses/goggles and dust mask if mechanical fabrication is to take place. SPILL, LEAK, OR RELEASE PROCEDURES: SPILL, LEAK, OR RELEASE PROCEDURES: SPILL, LEAK, OR RELEASE PROCEDURES: SPILL, LEAK, OR RELEASE PROCEDURES: SPILL, LEAK, OR RELEASE PROCEDURES: Normal good housekeeping should be observed. Material can be swept or picked up and placed into a suitable container for disposal. REPORTABLE QUANTITY:REPORTABLE QUANTITY:REPORTABLE QUANTITY:REPORTABLE QUANTITY:REPORTABLE QUANTITY: None DISPOSAL METHOD:DISPOSAL METHOD:DISPOSAL METHOD:DISPOSAL METHOD:DISPOSAL METHOD: Recycle, incinerate (WTE) or landfill per local and state regulations. Perform Guard® EPS R-Control® Perform Guard EPS is a termite resistant expanded polystyrene insulation for all types of R-Control construction. It is used in Structural Insulated Panels (SIPs), Insulated Concrete Forms (ICFs), Perim- eter and Under-slab Foundation Insulaton, Geofoam, and other R-Control Building Systems. Resistant to termite damage Resistant to carpenter ant damage Non-toxic, safe to handle Incorporates EPA registered material Meets code requirements for ground contact Cost effective The Problem Insulation helps keep people comfortable. Unfor- tunately, insulations are susceptible to termite infestation. Termites love to live, work and eat in comfortable and protected surroundings. All untreated insulation can potentially provide this environment. Most of the U.S. is susceptible to termite activity. It is important that insulation systems account for potential termite infestation. Termites reduce insulation & system performance Termites cause problems for structural systems Costs to control termites can continue indefinitely The Solution - Perform Guard EPS R-Control Perform Guard EPS is an important component in preventing this problem. It's made by a patented process using an inorganic mineral that is a natural deterrent to termites. This mineral is incorporated into the insulation during the manufacturing process. It is registered with the Environmen- tal Protection Agency (EPA) for this application. Perform Guard EPS has been thoroughly tested, is safe, noncorrosive and nontoxic. And termites hate it. Perform Guard is a termite resistant insulation. Perform Guard is not a barrier system, but should be used in conjunction with a total insect man- agement program available from a reputable pest control operator. Applications Perform Guard EPS must be used in conjunction with approved adhesive/sealants to ensure opti- mum performance. R-Control Building Systems developed Do-All-Ply® specifically for use with Perform Guard insulation. Do-All-Ply is used to adhere Perform Guard to substrates and fill board joints. Below grade application of Perform Guard EPS All surfaces must be clean, dry, free of dirt, oil, dust and release agents. Remove excess mortar and other irregularities from concrete/masonry wall. Apply continuous layer of Do-All-Ply with 1/4" V-notched trowel over the entire substrate or directly to Perform Guard EPS board. Apply no more Do-All-Ply than can be bonded within 15 minutes. At all joints - apply a continuous 3/8" diameter bead of Do-All-Ply. Ensure the joints between adjacent pieces of Perform Guard EPS are tightly butted together. For Perform Guard EPS ICF Systems, apply at joints in a similar manner. After placement of foam, allow Do- All-Ply to cure for 48 hours before covering with other materials. See Perform Guard EPS installation details for further information. Testing R-Control Building Systems has conducted extensive research to: find an effective non-toxic additive that would deter termites, develop processes for the incorporation of the additive into EPS; and "test prove" and "field prove" the efficacy of the Perform Guard EPS. Termite exposure tests have been conducted by industry recognized insti- tutions following test standards. Untreated foam insulations are shown in the photos below. Product performance testing has shown how R-Control's Perform Guard EPS resists termite infestation when installed following our recommendations. In addition, Perform Guard EPS has demonstrated resistance to carpenter ants. Code Compliant Perform Guard EPS has been evaluated for below grade use by the NES and SBCCI PST & ESI. Please see NER-551 and SBCCI PST & ESI Evaluation Report #94136D. For application instructions, please refer to specific guidelines and technical information available from R-Control Building Systems. Specification Specify Perform Guard EPS to ensure the long term performance of your insulation system. 1.GENERAL - The insulation system(s) specified in this division will be comprised of an integrally treated R-Control Perform Guard EPS. Manufacturer must provide data showing efficacy of the non-corrosive, non-toxic treatment against wood-boring insects, specifically termites and carpenter ants. Test standards modeled after ASTM D3345-74 and AWPA E7-93 must be used. Submit data confirming treatment, safety, efficacy, and in- plant quality assurance regarding the R-Control Perform Guard and related systems. 2.PRODUCTS - Furnish the ________________ (appropriate R-Control Building System) manufactured with Perform Guard EPS treated to resist termites. Perform Guard EPS is manufactured to meet the physical standards of ASTM C578. Provide full systems applications as specified in other sections of the specification. Appropriate listing and approvals for materials and systems must also be maintained. Manufacturer will supply submittal data as required. 3.EXECUTION - Install the R-Control Perform Guard EPS insulation system per drawings and manufacturer's installation guidelines. See detailed specifications for the insulation system shown on the drawings. Termite Damaged Untreated Foams Quality Assurance and Warranty R-Control Perform Guard EPS is manufactured to Quality Control Program standards monitored by Underwriters Laboratories Inc.® and recognized by national codes. R-Control Building Systems offer product warranties ensuring termite resistance, structural integrity and thermal performance. For complete details, please contact R-Control Building Systems. Environmental Advantages Perform Guard EPS Insulation... Contains no CFCs, HCFCs, or HFCs Contains no formaldehyde Can be recycled Inert, non-nutritive, highly stable Will not decompose, decay or produce gases or leachates Availability R-Control Building Systems is North America's largest provider of Expanded Polystyrene (EPS) Insula- tion Systems with manufacturing/sales facilities located throughout the U.S., Puerto Rico, and Japan. Please contact your R-Control Building Systems supplier for design consultation, availability and pricing. Perform Guard EPS has been tested against termites and carpenter ants. A list of specific species is on file. Perform Guard is protected under U.S. Patents No. 5,194,323 and No. 5,270,108. Copyright © AFM Corporation 2001. All rights reserved. 2/01 Printed in USA. R-Control, Perform Guard, and Do-All-Ply are registered trademarks of AFM Corporation, Excelsior, MN. The ENERGY STAR logo recognizes insulation as a product that saves energy, money, and helps the environment. To learn more, ask a salesperson for the ENERGY STAR Insulation Guide, or call 1-888-STAR-YES. The ENERGY STAR logo does not imply EPA or DOE endorsement of any product or service. R-Control Building Systems 24000 W. Highway 7 Suite 201 Excelsior, MN 55331 Fax: 952/474-2074 TOLL FREE: 800/255-0176 www.r-control.com Industry Affiliations: ICFA, EPSMA, NAHB NRCA, SIPA, AIA Consult R-Control EPS brochure for additional perfor- mance characteristics, physical properties and use limitations. SAMP LEPerform Guard® EPS Warranty The following Perform Guard® Licensed Manufacturer Facility Name: Location: Produces Perform Guard EPS under a patented treatment process with an EPA registered compound. The Perform Guard® EPS, which incorporates this additive, has exhibited a high resistance to termites and carpenter ants. Extensive testing, modeled after ASTM D 3345-74 and WPA EL12-72, has been conducted on Perform Guard EPS. Tested insula- tion has exhibited minimal aesthetic damage after test exposure to various species of termites and carpenter ants found in North America. A list of the specific species is available from the Perform Guard Licensed Manufacturer. Limited Warranty The Perform Guard Licensed Manufacturer hereby warrants to the Installer/Owner for a period of 3 years from date of invoice that the Perform Guard EPS will remain serviceable for its intended use. Conditions for Warranty As a condition precedent for entitlement to this warranty, the Installer/Owner must fully comply with all the instruc- tions for handling, storing and installing the Perform Guard EPS, together with proper site preparation and mainte- nance where this Perform Guard EPS is to be installed, all as provided in Protection Practices and Conditions as part of this warranty. Procedures to Exercise Remedies 1. Immediately upon discovering infestation of the Perform Guard EPS, the Installer/Owner shall report such fact in writing to the Perform Guard Licensed Manufacturer shown on this warranty. 2. Promptly the Perform Guard Licensed Manufacturer shall cause an examination to be made to determine that the Installer/Owner is properly qualified for this warranty and to determine whether or not there has been a failure of serviceability of the Perform Guard EPS for its intended use. The Perform Guard Licensed Manufacturer shall be guided in its determination by the published physical characteris- tics shown on its UL AFM Certificate. 3. Where it is determined that there has been a failure of serviceability for its intended use of the affected Perform Guard EPS, the Perform Guard Licensed Manufacturer in its sole discretion may offer any of the following remedies: a. The Perform Guard Licensed Manufacturer at its own expense may order field treatment of the affected Perform Guard EPS by a licensed pest control operator, including follow-up treatment, not to exceed a total of two applica- tions. b. The Perform Guard Licensed Manufacturer or its autho- rized representative may employ nondestructive methods to accomplish repairs. c. The Perform Guard Licensed Manufacturer or its autho- rized representative may repair or replace the unservice- able Perform Guard EPS by any reasonable means. d. In no event shall the cost of any repair or replacement as may be required exceed the original cost of the affected Perform Guard EPS. Exceptions and Limitations In addition to all other exceptions set forth herein, this Warranty Agreement shall not cover any failure of the Perform Guard EPS due to: 1. Excessive heat beyond design considerations, or fire. 2. The effect of any solvent on the Perform Guard EPS. 3. The effect of coal tar pitch on the Perform Guard EPS. 4. Moisture resulting from improper installation and application of the Perform Guard EPS. Moisture resulting from a malfunction or failure of other system components, systems or construction. 5. The effect of building movement. 6. The effect of insect, vermin or animal intrusion outside the scope of this warranty. 7. The effect of ultraviolet light attack. 8. The effect of equipment traffic or other compressive loads that exceed the design limits of the Perform Guard EPS. 9. The effect of other external forces not under the control of the Perform Guard Licensed Manufacturer. SAMP LEPage 2 0f 3 PG Warranty Additional Terms, Conditions, and Limitations The Perform Guard Licensed Manufacturer shall not be obligated under the terms of this limited warranty until the party (or parties) contracting for the Perform Guard EPS materials has paid, in full, all invoices and charges for materials, installation and services due and owing. Owner shall notify the Perform Guard Licensed Manufac- turer in writing, within sixty (60) days after the owner of the warranted Perform Guard EPS becomes aware of any dam- age. This Warranty shall not be enforceable if, in the judgment of the Perform Guard Licensed Manufacturer, any of the following shall occur: 1. The Perform Guard EPS is damaged by any natural cause including, but not limited to, lightning, strong wind, hurricane, tornado, hail, earthquake, or flood. 2. The Perform Guard EPS is damaged by any act of negligence, including overexposure to the elements, any accident or any intentional or unintentional mis use. 3. Metal work or other material used in the system which causes loss of physical properties in the Perform Guard EPS. 4. If, after installation of the Perform Guard EPS, there are any alterations, or repairs made on or through the Perform Guard EPS, or if anything is placed upon or attached to the Perform Guard EPS not in compliance with R-Control recommended details. 5. Failure to use reasonable care in maintaining the Perform Guard EPS and the system. 6. The owner of the warranted Perform Guard EPS fails to comply with any of the obligations stated in this Warranty Agreement. Protection Practices and Conditions The Perform Guard EPS has been proven effective in inde- pendent testing to be resistant to specific species of ter- mites and carpenter ants. A list of specific species is kept on file at the Perform Guard Licensed Manufacturer. It is recognized that at some time a structure will be subjected to visitation by insects. The following good building prac- tices and general conditions must be maintained so your Perform Guard EPS will not be as susceptible to insect damage. These practices and conditions must be em- ployed to keep the Perform Guard warranty in effect. Building Practices 1. General Site Sanitation: Remove all stumps, roots, and wood debris from the job site. Removal of stumps must include those within the property lines or 100' of the structure. 2. Termite prone areas must utilize recommended baiting systems and/or perimeter soil and footing treatment with termiticide chemicals before and after backfilling, including areas under concrete slabs. 3. Building code requirements for proper design and protection against decay and termites must be followed. 4. All crawl spaces and or porches must have adequate ventilation and a minimum wood to soil clearance of 18" to floor joist and 12" to floor girder. Ventilation requirements are spelled out in major model building codes. 5. Wood, wood scraps, paper and cellulose containing products are not to be buried on jobsite particularly in backfill area and under the structure. 6. All masonry foundations must be made as impervious as possible with solid concrete caps. Do not use waterproofing, dampproofing or drainage systems that are susceptible to insect activity. 7. Use pressure treated lumber for base plates, sill plates and other high moisture areas including any wood/soil contacts. 8. All sites must be graded so good drainage occurs. Grade must have minimum clearance of 8" to base plate or framing and 6" to siding. 9. Use construction details and flashings which will minimize the potential of moisture related damage to the structure. 10. Proper caulking of siding and penetrations must take place. General Conditions 1. Known ant and termite colonies on property or within 100' of structure must be eliminated by removal or chemical treatment. 2. Inspect gutters and flashings to ensure proper drainage is occurring. Repair all leaks immediately. SAMP LEPage 3 of 3 PG Warranty 3. Repair any trees with damage to crotches, broken limbs, or holes with proven horticultural methods. 4. Store firewood off the ground and well away from structure. 5. Bring only firewood for immediate use into the structure. 6. Trim all trees and shrubs so no branches make contact or overhang any portion of the structure. 7. Do not plant shrubs within 18" of the structure's base. 8. Keep the humidity levels inside the structure below 50%. 9. Keep house clean of garbage and foodscraps. Keep all animal food in closed containers. For additional information, consult Perform Guard series of Technical Bulletins available at: www.R-Control.com Disclaimers THERE ARE NO WARRANTIES, INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, WHICH EXTEND BEYOND THE WARRANTIES SET FORTH IN THIS WARRANTY, AND IN NO EVENT SHALL THE PERFORM GUARD LICENSED MANUFACTURER OR AFM CORPORATION BE LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LOSSES ARISING OUT OF OR IN ANY WAY RELATING TO THIS WARRANTY OR ANY DESIGN OR MANUFACTURING DEFECT, EVEN IF THE PER- FORM GUARD LICENSED MANUFACTURER OR AFM COR- PORATION HAS BEEN ADVISED OF THE POSSIBILITY THEREOF. NO OTHER WARRANTIES, EXPRESSED OR IMPLIED, ARE PROVIDED BEYOND THE TERMS, CONDI- TIONS, REMEDIES AND LIMITS SET FORTH IN THIS WAR- RANTY. NO EMPLOYEE, REPRESENTATIVE OR AGENT OF THE PERFORM GUARD LICENSED MANUFACTURER OR AFM CORPORATION MAY AUTHORIZE CHANGES TO THIS WARRANTY, OR OTHERWISE ALTER THE TERMS, CONDI- TIONS, REMEDIES AND LIMITS SPECIFICALLY SET FORTH IN THIS WARRANTY FORM. Perform Guard is not a barrier system. Insects may enter in through other access areas. Perform Guard EPS is produced exclusively by Licensed Facilities of AFM Corporation. Perform Guard, R-Control and AFM are registered trade- marks of AFM Corporation. Protected under U.S. Patents No. 5,194,323 and No. 5,270,108. Other U.S. and Foreign Patents Pending. 11/03 Warranty and Damages (a)Warranty: Thermo-Form warrants that its Products will be free from defects in workmanship and materials under normal use and service, for a period of 12 months from the date of their initial installation (BUT NOT FOR MORE THAN 18 MONTHS FROM THE DATE OF DELIVERY PURSUANT TO SECTION 2 OF THESE TERMS AND CONDITIONS OF SALE). Any warranty is void in cases of damage in transit, negligence, abuse, abnormal usage or storage, misuse, accidents, or improper installation or maintenance or failure to use or maintain in accordance with Thermo-Form's or any supplier's instructions or manuals. Any warranty is void if the Products are not covered in accordance with instructions or manuals to prevent sunlight degradation. Thermo-Form makes no warranty regarding installation services provided by subcontractors of Thermo-Form or any other party. Any defects arising from or relating to Buyer's specifications are not covered by Thermo-Form's warranty. Thermo-Form makes no warranty regarding water infiltration in below grade applications, and Thermo-Form makes no warranty for applied coatings or other interior or exterior treatments. Thermo-Form makes no warranty regarding parts or products manufactured or supplied by third parties. Buyer shall be responsible for promptly notifying Thermo-Form of any warranty claims as described above. Buyer acknowledges that the metal components of the TF system are subject to national building codes and specifications. Consequently, THERMO-FORM MAKES NO WARRANTY REGARDING PRODUCT SOLD HEREUNDER IF ANY PORTION OF THE METAL COMPONENT IS NOT MANUFACTURED BY THERMO-FORM OR PURCHASED FROM A SUPPLIER APPROVED IN ADVANCE IN WRITING BY THERMO-FORM. THERMO-FORM'S SOLE OBLIGATION UNDER THIS WARRANTY SHALL BE, UPON PROMPT WRITTEN NOTICE BY BUYER OF ANY DEFECT, TO REPAIR WITHOUT CHARGE, F.O.B. THERMO-FORM'S FACILITY, ANY DEFECTIVE PRODUCT EXPRESSLY WARRANTED HEREIN AGAINST DEFECTS BY THERMO-FORM OR, AT THERMO-FORM'S OPTION, TO CREDIT BUYER'S ACCOUNT FOR THE PORTION OF THE PURCHASE PRICE RELATING TO THE DEFECTIVE PRODUCT. BUYER SHALL PAY ALL EXPENSES ASSOCIATED WITH THE REMOVAL, REINSTALLATION AND FREIGHT IN CONNECTION WITH THE FOREGOING REMEDY. THERMO-FORM SHALL NOT BE LIABLE TO BUYER, OR TO ANYONE CLAIMING UNDER BUYER, FOR ANY OTHER OBLIGATIONS OR LIABILITIES, INCLUDING, BUT NOT LIMITED TO, OBLIGATIONS OR LIABILITIES ARISING OUT OF BREACH OF CONTRACT OR WARRANTY, NEGLIGENCE OR OTHER TORT OR ANY THEORY OF STRICT LIABILITY, WITH RESPECT TO THE PRODUCTS, THEIR INSTALLATION, INSTRUCTIONS, DEFECTS FROM ANY CAUSE OR THERMO- FORM'S REPRESENTATIONS, WARRANTIES, ACTS OR OMISSIONS. This warranty covers only replacement or repair of defective Products at Thermo-Form's main office and does not include field service travel and living. On Products or parts thereof furnished by Thermo-Form, but manufactured by others, Thermo-Form makes NO WARRANTY. The written warranty of the manufacturer, if any, will be assigned to Buyer if assignment is reasonably practicable. However, Thermo-Form does not adopt or guarantee or represent that the manufacturer will comply with any of the terms of the warranty of such manufacturer. Thermo- Form will manage and coordinate warranty service for all parts and components of the Products, but Thermo-Form does not guarantee the warranty performance or service of the manufacturers or vendors Thermo-Form procures to provide such warranty service. Thermo-Form will not be liable for any loss, cost, expense or damages of any nature relating to the warranty performance and/or service of any such manufacturers or vendors. Thermo-Form will not reimburse Buyer for any expenses incurred by Buyer in repairing or replacing any defective Products, except for those incurred with Thermo-Form's prior written permission. Thermo-Form shall have the right to dispose of parts it replaces. (b) Damages: IN NO EVENT SHALL THERMO-FORM BE LIABLE FOR INCIDENTAL, CONSEQUENTIAL, INDIRECT OR SIMILAR DAMAGES OR DAMAGES FOR LOSS OF USE, REVENUE OR PROFIT, OR FOR COST OF CAPITAL OR OF SUBSTITUTE USE OR PERFORMANCE, OR FOR ANY OTHER LOSS OR COST OF SIMILAR TYPE. THERMO- FORM'S AGGREGATE LIABILITY WITH RESPECT TO DEFECTIVE PRODUCTS SHALL BE LIMITED TO THE MONIES PAID BY BUYER TO THERMO-FORM FOR THE DEFECTIVE PRODUCTS MANUFACTURED BY THERMO-FORM. Thermo-Form shall not, under any circumstances, be liable for default, negligence or the acts or omissions of Buyer or Buyer's employees or Buyer's other contractors or suppliers and Buyer indemnifies Thermo-Form against and holds it harmless from any loss, damage, cost or expense (including without limitation reasonable attorneys' fees) resulting from or due to such acts or omissions. Thermo-Form shall not, under any circumstances, be liable for any errors or omissions contained in specifications or drawings provided by Buyer, and Buyer indemnifies Thermo-Form against and holds it harmless from any loss, damage, cost or expense (including without limitation reasonable attorneys' fees) resulting from or due to such errors or omissions. Thermo-Form, in its manufacture and sale of these Products, assumes no liability as to possible infringements of patents by virtue of the use of such Products in combination with other elements or structures and Buyer hereby indemnifies and holds harmless Thermo-Form against all damages sustained by Thermo-Form (including without limitation reasonable attorneys' fees) resulting from any action or threatened action against Thermo-Form related thereto. Disclaimer of Warranties. THERMO-FORM AND BUYER AGREE THAT THE WARRANTIES IN THE PRECEDING SECTION ARE EXCLUSIVE AND IN LIEU OF ALL OTHER EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. THERMO-FORM HEREBY DISCLAIMS AND EXCLUDES ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE AND ALL OTHER EXPRESS OR IMPLIED WARRANTIES. Any oral or written description of the Products is for the sole purpose of identifying the Products and shall not be construed as an express warranty.