812 Ocean Blvd RES21-0158 5th submittal 7 of 7 ss-garuf (1)_1SS-GARUF www.goodmanmfg.com 6/21 Supersedes 6/21 Contents Nomenclature .......................................2 Product Specifications ..........................3 Heater Kit Nomenclature ......................3 Dimensions ...........................................4 Airflow Data ..........................................5 Heat Kit Data .........................................6 Wiring Diagrams .................................13 Accessories .........................................15 * Complete warranty details available from your local dealer or at www.goodmanmfg.com. To receive the 10-Year Parts Limited Warranty, online registration must be completed within 60 days of installation. Online registration is not required in California or Québec. Multi-Position, Multi-speed Air Handler with PSC Motor 1½ to 5 Tons Product Features • Check flowrator for cooling and heat pump applications • Direct drive, multi-speed PSC blower motor • All-aluminum evaporator coil • Coil mounting track for quick repositioning • Cabinet air leakage less than 2.0% at 1.0 inch H₂O when tested in accordance with ASHRAE standard 193 • Cabinet air leakage less than 1.4% at 0.5 inch H₂O when tested in accordance with ASHRAE standard 193 • AHRI certified; ETL listed • Rigid SmartFrame™ cabinet • Horizontal or vertical configuration capabilities • 21" depth for easier attic access • DecaBDE-free thermoplastic drain pan with secondary drain connections • Screw-less sides and back helps to reduce condensation when installed in humid locations • Foil-faced insulation covers the internal casing to reduce cabinet condensation • Galvanized, leather grain-embossed finish • Glue-less cabinet insulation retention • Tool-less filter access • Field Installed 3 kW – 25 kW electric heater kits available ARUF Series 2 www.goodmanmfg.com SS-GARUF Nomenclature HKS X 03 X A AA 1 2 3 4 5 6,7 Unit  Type Revisions HKS Heat  Kit  for  Engineering  Revisions Air  Handlers Phase Circuit  Breaker E      Three  Phase  240  V X No  circuit  breaker F      Three  Phase  208/240  V C Circuit  Breaker G      Three  Phase  460  V A      Single  Phase  208  V B      Single  Phase  240  V C      Single  Phase  208/240  V D      Three  Phase  208  V H Special case 208 V *Heating  Capacity  @  240  Volts 03 3.0  kW 15 14.4  kW Cabinet  Size  (MAX) 05 4.5  kW 19 19.2  kW  wth  150F  limit C      C  Cabinet 06 6.0  kW 20 19.2  kW  with  170F  limit D      D  Cabinet 08 8.0  kW 25 25.0  kW X      All  Cabinet  Sizes 10 9.6  kW *Refer S&R Plate B 1 7 8 Brand Engineering  * A Single-­‐piece Major/  Minor  Revisions Air  Handler *   Not  used  for  inventory  management Unit  Application Refrigerant  Charge C Ceiling  Mount  PSC  Motor 4  =  R-­‐410A D Downflow  PSC  Motor E Multi-­‐Position  Variable-­‐Speed  Motor Electrical R Multi-­‐Position  PSC  Motor 1      208/240  V,  1  Phase,  60  Hz S Multi-­‐Position  EEM  Motor W Wall  Mount  PSC  Motor Cabinet  Width B    17½" Cabinet  Finish C    21" U Unpainted D      24½" P Painted N Uncased Nominal  Capacity  Range  @  13  SEER 43, 47 – 3½  TonsExpansion  Device 25, 29 – 2 Tons      49 – 4 Tons F Flowrator 31 – 2½  Tons 61 – 5 Tons T Expansion  Valve 37 – 3 Tons AA 11,12 U 3 F 4 10 4R 2 5,6 18 1 A SS-GARUF www.goodmanmfg.com 3 Product Specifications ARUF 25B14* ARUF 29B14* ARUF 31B14* ARUF 37C14* ARUF 37D14* ARUF 43C14* ARUF 43D14* ARUF 47D14* ARUF 49C14* ARUF 49D14* ARUF 61D14* Nominal Ratings Cooling (Btu/h)24,000 25,000 30,000 36,000 36,000 42,000 42,000 43,000 48,000 48,000 60,000 Piston Size 0.051 0.057 0.065 0.072 0.072 0.076 0.076 0.076 0.080 0.080 0.080 Blower Diameter 9½"9½"9½"10⅝"10⅝"10⅝"10⅝"10⅝"10⅝"10⅝"1115/16" Width 6"6"6"8"10⅝"8"10⅝"10⅝"10⅝"10⅝"10⅝" Coil Connections Liquid ⅜"⅜"⅜"⅜"⅜"⅜"⅜"⅜"⅜"⅜"⅜" Suction ¾"¾"⅞"⅞"⅞"⅞"⅞"⅞"⅞"⅞"⅞" Coil Drain Connect (FPT)¾"¾"¾"¾"¾"¾"¾"¾"¾"¾"¾" Electrical Data Voltage 208/230 208/230 208/230 208/230 208/230 208/230 208/230 208/230 208/230 208/230 208/230 Min Circuit Ampacity 2.2/2.2 2.2/2.2 2.2/2.2 3.6/3.6 3.6/3.6 3.6/3.6 4/4 4/4 4/4 4/4 6/6 Max. Overcurrent Device (Amps)15/15 15/15 15/15 15/15 15/15 15/15 15/15 15/15 15/15 15/15 15/15 Minimum VAC 197 197 197 197 197 197 197 197 197 197 197 Maximum VAC 253 253 253 253 253 253 253 253 253 253 253 Blower Motor Full Load Amps (FLA)1.75 1.75 1.75 2.85 2.85 2.85 3.5 3.5 3.1 3.5 4.6 Horsepower (HP)⅓⅓⅓⅓⅓½⅓½½½¾ Ship Weight (Lbs.)100 100 110 130 140 130 145 150 135 145 155 Note: For a properly matched system and piston sizing information, refer to Amana piston kit chart of the corresponding Amana® outdoor unit. Minimum Circuit Ampacity (MCA) and Maximum Overcurrent Protection (MOP) for blower without supplemental heat installed. Refer to unit nameplate and/or Heat Kit Data for specification with approved accessory heaters installed. 4 www.goodmanmfg.com SS-GARUF Dimensions G H E D 1 3/4" (4.45 cm) 2 11/16" (6.83 cm) C B 5/8" (1.59 cm) 5/8" (1.59 cm) A 1/2" (1.27 cm) 11 5/16" (28.73 cm) " (55.88 cm)21 9 1/4" (23.50 cm) 1 3/8" (3.49 cm) 3 1/8" (7.94 cm) 5 1/8" (13.02 cm) 7 1/2" (19.05 cm) 1 3/4" (4.45 cm) 7 3/16" (18.26 cm) K J 2 1/8" (5.40 cm) 4 5/16" (4.31 cm) 6 1/8" (15.56 cm) 1 13/16" (4.60 cm) FINLET(FRONT VIEW) 1 13/16" (4.60 cm) " (2.54 cm)1 9/16 (1.43 cm) 19.5" (49.53 cm)INLET(RIGHT SIDE VIEW) 10 3/16" (25.88 cm) 1 5/8" (4.13 cm) 1 5/16" (3.33 cm) 4 1/2" (11.43 cm) 1 5/8" (4.13 cm) 3 3/4" (9.53 cm) 2 15/16" (7.46 cm) 3 1/16" (7.78 cm) SEE HORIZONTAL DRAIN PORT DETAIL SEE VERTICAL DRAIN PORT DETAIL SUCTION TUBE LIQUID LINE INLET TUBE HORIZONTAL DRAIN PORT DETAIL VERTICAL DRAIN PORT DETAIL Model A"B"C"D"E"F"G"H" ARUF25B14*45 16⅜17½15¼12 14⅛9⅛11⅞ ARUF29B14*45 16⅜17½15¼12 14⅛9⅛12¾ ARUF31B14*537/16 16⅜17½2311/16 20½14⅛9⅛7⅝ ARUF37C14*537/16 19⅞21 2113/16 18⅝1711/16 1013/16 613/16 ARUF43C14*537/16 19⅞21 2113/16 18⅝1711/16 1013/16 613/16 ARUF49C14*537/16 19⅞21 2113/16 18⅝1711/16 1013/16 613/16 ARUF37D14*537/16 235/16 24½21½185/16 213/16 12⅝6⅞ ARUF43D14*537/16 235/16 24½21½185/16 213/16 12⅝6⅞ ARUF47D14*58 235/16 24½26⅛22⅞213/16 12⅝252/16 ARUF49D14*537/16 235/16 24½21½185/16 213/16 12⅝6⅞ ARUF61D14*58 235/16 24½26⅛22⅞213/16 12⅝252/16 SS-GARUF www.goodmanmfg.com 5 Model Motor Speed Static Pressure (in w.c) Airflow (CFM) 0.1 0.2 0.3 0.4 0.5 0.6 0.7 ARUF25B14 Low 650 620 595 540 490 420 275 Med 885 865 825 815 750 690 560 High 1255 1225 1130 1090 965 925 800 ARUF29B14 Low 650 620 595 540 490 420 275 Med 885 865 825 815 750 690 560 High 1255 1225 1130 1090 965 925 800 ARUF31B14 Low 660 625 595 560 500 430 330 Med 930 905 865 820 765 700 590 High 1235 1185 1130 1060 990 910 825 ARUF37C14 Low 1120 1085 1040 1000 940 875 800 Med 1425 1385 1345 1285 1220 1145 1060 High 1625 1575 1520 1460 1375 1295 1200 ARUF43C14 Low 1120 1085 1040 1000 940 875 800 Med 1425 1385 1345 1285 1220 1145 1060 High 1625 1575 1520 1460 1375 1295 1200 ARUF49C14 Low 1295 1255 1225 1175 1120 1055 970 Med 1535 1485 1420 1370 1295 1215 1130 High 1755 1680 1590 1515 1425 1340 1250 ARUF37D14 Low 1155 1115 1070 1015 955 895 840 Med 1505 1470 1430 1375 1300 1210 1105 High 1785 1735 1680 1625 1555 1440 1330 ARUF43D14 Low 1410 1360 1290 1210 1120 1010 920 Med 1610 1540 1470 1390 1300 1190 1060 High 1900 1830 1740 1645 1540 1420 1280 ARUF47D14 Low 1420 1370 1310 1240 1125 1045 960 Med 1625 1585 1515 1435 1350 1235 1095 High 1930 1890 1820 1735 1635 1505 1355 ARUF49D14 Low 1410 1360 1290 1210 1120 1010 920 Med 1610 1540 1470 1390 1300 1190 1060 High 1900 1830 1740 1645 1540 1420 1280 ARUF61D14 Low 1530 1500 1460 1405 1350 1280 1155 Med 1950 1885 1830 1785 1745 1670 1595 High 2235 2170 2100 2030 1965 1915 1825 Notes• Airflow data indicated is at 230V without air filter in place. • The chart is for information only. For satisfactory operation, external static pressure must not exceed value shown on rating plate. The shaded area indicates ranges in excess of maximum design external static pressure. • Use the CFM adjustment factors of 0.98 for horizontal left and 0.96 for horizontal right & downflow orientations Airflow Data 6 www.goodmanmfg.com SS-GARUF Heat Kit Data See notes on page 12. Heater Kit Model Circuit 1 Circuit 2 Single-Point Kit Amps MCA¹MOP²Amps MCA¹MOP²MCA¹MOP² ARUF25B14AC 0/0 2.2/2.2 15/15 --------------- HKSX03XC - 208 V No Breaker 10.8 16 20 --------------- HKSX05XC - 208 V 17.3 24 25 --------------- HKSX06XC - 208 V 21.7 29 30 --------------- HKSX08XC - 208 V 28.9 38 40 --------------- HKSX10XC - 208 V 34.7 46 50 --------------- HKSC05XC - 208 V Breaker 17.3 24 25 --------------- HKSC08XC - 208 V 28.9 38 40 --------------- HKSC10XC - 208 V 34.7 46 50 --------------- HKSX03XC - 240 V No Breaker 12.5 18 20 --------------- HKSX05XC - 240 V 20 27 30 --------------- HKSX06XC - 240 V 25 33 35 --------------- HKSX08XC - 240 V 33.3 44 45 --------------- HKSX10XC - 240 V 40.0 52 60 --------------- HKSC05XC - 240 V Breaker 20 27 30 --------------- HKSC08XC - 240 V 33.3 44 45 --------------- HKSC10XC - 240 V 40.0 52 60 --------------- ARUF29B14AC 0/0 2.2/2.2 15/15 --------------- HKSX03XC - 208 V No Breaker 10.8 16 20 --------------- HKSX05XC - 208 V 17.3 24 25 --------------- HKSX06XC - 208 V 21.7 29 30 --------------- HKSX08XC - 208 V 28.9 38 40 --------------- HKSX10XC - 208 V 34.7 46 50 --------------- HKSC05XC - 208 V Breaker 17.3 24 25 --------------- HKSC08XC - 208 V 28.9 38 40 --------------- HKSC10XC - 208 V 34.7 46 50 --------------- HKSX03XC - 240 V No Breaker 12.5 18 20 --------------- HKSX05XC - 240 V 20 27 30 --------------- HKSX06XC - 240 V 25 33 35 --------------- HKSX08XC - 240 V 33.3 44 45 --------------- HKSX10XC - 240 V 40.0 52 60 --------------- HKSC05XC - 240 V Breaker 20 27 30 --------------- HKSC08XC - 240 V 33.3 44 45 --------------- HKSC10XC - 240 V 40.0 52 60 --------------- ARUF31B14AC 0/0 2.2/2.2 15/15 --------------- HKSX03XC - 208 V No Breaker 10.8 16 20 --------------- HKSX05XC - 208 V 17.3 24 25 --------------- HKSX06XC - 208 V 21.7 29 30 --------------- HKSX08XC - 208 V 28.9 38 40 --------------- HKSX10XC - 208 V 34.7 46 50 --------------- HKSC05XC - 208 V Breaker 17.3 24 25 --------------- HKSC08XC - 208 V 28.9 38 40 --------------- HKSC10XC - 208 V 34.7 46 50 --------------- HKSC15XA - 208 V 34.7 46 50 17.3 22 25 67 70 SS-GARUF www.goodmanmfg.com 7 Heat Kit Data (cont.) See notes on page 12. Heater Kit Model Circuit 1 Circuit 2 Single-Point Kit Amps MCA¹MOP²Amps MCA¹MOP²MCA¹MOP² HKSX03XC - 240 V No Breaker 12.5 18 20 --------------- HKSX05XC - 240 V 20 27 30 --------------- HKSX06XC - 240 V 25 33 35 --------------- HKSX08XC - 240 V 33.3 44 45 --------------- HKSX10XC - 240 V 40.0 52 60 --------------- HKSC05XC - 240 V Breaker 20 27 30 --------------- HKSC08XC - 240 V 33.3 44 45 --------------- HKSC10XC - 240 V 40.0 52 60 --------------- HKSC15XB - 240 V 40.0 52 60 20 25 25 77 80 ARUF37C14AD 0/0 3.6/3.6 15/15 --------------- HKSX03XC - 208 V No Breaker 10.8 17 20 --------------- HKSX05XC - 208 V 17.3 25.2 30 --------------- HKSX06XC - 208 V 21.7 31 35 --------------- HKSX08XC - 208 V 28.9 40 40 --------------- HKSX10XC - 208 V 34.7 46.9 50 --------------- HKSC05XC - 208 V Breaker 17.3 25.2 30 --------------- HKSC08XC - 208 V 28.9 40 40 --------------- HKSC10XC - 208 V 34.7 46.9 50 --------------- HKSC15XA - 208 V 34.7 46.9 50 17.3 22 25 68.6 70 HKSC19CA - 208 V 34.7 46.9 50 34.7 43 45 90.2 100 HKSC15XF - 208 V ^0 3.6 15 30 38 40 ------ HKSC20XF - 208 V ^0 3.6 15 38 47 50 ------ HKSX03XC - 240 V No Breaker 12.5 19 20 --------------- HKSX05XC - 240 V 20 29 30 --------------- HKSX06XC - 240 V 25 35 35 --------------- HKSX08XC - 240 V 33.3 45.2 50 --------------- HKSX10XC - 240 V 40 53.6 60 --------------- HKSC05XC - 240 V Breaker 20 29 30 --------------- HKSC08XC - 240 V 33.3 45.2 50 --------------- HKSC10XC - 240 V 40 53.6 60 --------------- HKSC15XB - 240 V 40 53.6 60 20 25 25 78.6 80 HKSC19CB - 240 V 40 53.6 60 40 50 50 104 110 HKSC15XF - 240 V ^0 3.6 15 34.6 43 45 ------ HKSC20XF - 240 V ^0 3.6 15 43 54 60 ------ ARUF37D14AD 0/0 3.6/3.6 15/15 --------------- HKSX03XC - 208 V No Breaker 10.8 17 20 --------------- HKSX05XC - 208 V 17.3 25.2 30 --------------- HKSX06XC - 208 V 21.7 31 35 --------------- HKSX08XC - 208 V 28.9 40 40 --------------- HKSX10XC - 208 V 34.7 46.9 50 --------------- 8 www.goodmanmfg.com SS-GARUF Heat Kit Data (cont.) See notes on page 12. Heater Kit Model Circuit 1 Circuit 2 Single-Point Kit Amps MCA¹MOP²Amps MCA¹MOP²MCA¹MOP² HKSC05XC - 208 V Breaker 17.3 25.2 30 --------------- HKSC08XC - 208 V 28.9 40 40 --------------- HKSC10XC - 208 V 34.7 46.9 50 --------------- HKSC15XA - 208 V 34.7 46.9 50 17.3 22 25 68.6 70 HKSC20DA - 208 V 34.7 46.9 50 34.7 43 45 90.2 100 HKSC15XF - 208 V ^0 3.6 15 30 38 40 ------ HKSC20XF - 208 V ^0 3.6 15 38 47 50 ------ HKSX03XC - 240 V No Breaker 12.5 19 20 --------------- HKSX05XC - 240 V 20 29 30 --------------- HKSX06XC - 240 V 25 35 35 --------------- HKSX08XC - 240 V 33.3 45.2 50 --------------- HKSX10XC - 240 V 40 53.6 60 --------------- HKSC05XC - 240 V Breaker 20 29 30 --------------- HKSC08XC - 240 V 33.3 45.2 50 --------------- HKSC10XC - 240 V 40 53.6 60 --------------- HKSC15XB - 240 V 40 53.6 60 20 25 25 78.6 80 HKSC20DB - 240 V 40 53.6 60 40 50 50 104 110 HKSC15XF - 240 V ^0 3.6 15 34.6 43 45 ------ HKSC20XF - 240 V ^ 0 3.6 15 43 54 60 ------ ARUF43C14AD 0/0 3.6/3.6 15/15 --------------- HKSX03XC - 208 V No Breaker 10.8 17 20 --------------- HKSX05XC - 208 V 17.3 25.2 30 --------------- HKSX06XC - 208 V 21.7 31 35 --------------- HKSX08XC - 208 V 28.9 40 40 --------------- HKSX10XC - 208 V 34.7 46.9 50 --------------- HKSC05XC - 208 V Breaker 17.3 25.2 30 --------------- HKSC08XC - 208 V 28.9 40 40 --------------- HKSC10XC - 208 V 34.7 46.9 50 --------------- HKSC15XA - 208 V 34.7 46.9 50 17.3 22 25 68.6 70 HKSC19CA - 208 V 34.7 46.9 50 34.7 43 45 90.2 100 HKSC15XF - 208 V ^0 3.6 15 30 38 40 ------ HKSC20XF - 208 V ^0 3.6 15 38 47 50 ------ HKSX03XC - 240 V No Breaker 12.5 19 20 --------------- HKSX05XC - 240 V 20 29 30 --------------- HKSX06XC - 240 V 25 35 35 --------------- HKSX08XC - 240 V 33.3 45.2 50 --------------- HKSX10XC - 240 V 40 53.6 60 --------------- SS-GARUF www.goodmanmfg.com 9 Heat Kit Data (cont.) See notes on page 12. Heater Kit Model Circuit 1 Circuit 2 Single-Point Kit Amps MCA¹MOP²Amps MCA¹MOP²MCA¹MOP² HKSC05XC - 240 V Breaker 20 29 30 --------------- HKSC08XC - 240 V 33.3 45.2 50 --------------- HKSC10XC - 240 V 40 53.6 60 --------------- HKSC15XB - 240 V 40 53.6 60 20 25 25 78.6 80 HKSC19CB - 240 V 40 53.6 60 40 50 50 104 110 HKSC15XF - 240 V ^0 3.6 15 34.6 43 45 ------ HKSC20XF - 240 V ^0 3.6 15 43 54 60 ------ ARUF43D14AC 0/0 4/4 15/15 --------------- HKSX03XC - 208 V No Breaker 10.8 18 20 --------------- HKSX05XC - 208 V 17.3 26 30 --------------- HKSX06XC - 208 V 21.7 31 35 --------------- HKSX08XC - 208 V 28.9 40.5 45 --------------- HKSX10XC - 208 V 34.7 48 50 --------------- HKSC05XC - 208 V Breaker 17.3 26 30 --------------- HKSC08XC - 208 V 28.9 40.5 45 --------------- HKSC10XC - 208 V 34.7 48 50 --------------- HKSC15XA - 208 V 34.7 48 50 17.3 22 25 69 70 HKSC20DA - 208 V 34.7 48 50 34.7 43 45 91 100 HKSC15XF - 208 V ^0 4 15 30 38 40 ------ HKSC20XF - 208 V ^0 4 15 38 47 50 ------ HKSX03XC - 240 V No Breaker 12.5 20 20 --------------- HKSX05XC - 240 V 20 29 30 --------------- HKSX06XC - 240 V 25 36 40 --------------- HKSX08XC - 240 V 33.3 46 50 --------------- HKSX10XC - 240 V 40 54 60 --------------- HKSC05XC - 240 V Breaker 20 29 30 --------------- HKSC08XC - 240 V 33.3 46 50 --------------- HKSC10XC - 240 V 40 54 60 --------------- HKSC15XB - 240 V 40 54 60 20 25 25 79 80 HKSC20DB - 240 V 40 54 60 40 50 50 104 110 HKSC15XF - 240 V ^0 4 15 34.6 43 45 ------ HKSC20XF - 240 V ^ 0 4 15 43 54 60 ------ ARUF47D14AC 0/0 4/4 15/15 --------------- HKSX03XC - 208 V No Breaker 10.8 18 20 --------------- HKSX05XC - 208 V 17.3 26 30 --------------- HKSX06XC - 208 V 21.7 31 35 --------------- HKSX08XC - 208 V 28.9 40.5 45 --------------- HKSX10XC - 208 V 34.7 48 50 --------------- 10 www.goodmanmfg.com SS-GARUF Heat Kit Data (cont.) See notes on page 12. Heater Kit Model Circuit 1 Circuit 2 Single-Point Kit Amps MCA¹MOP²Amps MCA¹MOP²MCA¹MOP² HKSC05XC - 208 V Breaker 17.3 26 30 --------------- HKSC08XC - 208 V 28.9 40.5 45 --------------- HKSC10XC - 208 V 34.7 48 50 --------------- HKSC15XA - 208 V 34.7 48 50 17.3 22 25 69 70 HKSC20DA - 208 V 34.7 48 50 34.7 44 45 91 100 HKSC15XF - 208 V ^0 4 15 30 38 40 ------ HKSC20XF - 208 V ^0 4 15 38 47 50 ------ HKSX03XC - 240 V No Breaker 12.5 20 20 --------------- HKSX05XC - 240 V 20 29 30 --------------- HKSX06XC - 240 V 25 36 40 --------------- HKSX08XC - 240 V 33.3 46 50 --------------- HKSX10XC - 240 V 40 54 60 --------------- HKSC05XC - 240 V Breaker 20 29 30 --------------- HKSC08XC - 240 V 33.3 46 50 --------------- HKSC10XC - 240 V 40 54 60 --------------- HKSC15XB - 240 V 40 54 60 20 25 25 79 80 HKSC20DB - 240 V 40 54 60 40 50 50 104 110 HKSC15XF - 240 V ^0 4 15 34.6 43 45 ------ HKSC20XF - 240 V ^ 0 4 15 43 54 60 ------ ARUF49C14AD 0/0 4/4 15/15 --------------- HKSX03XC - 208 V No Breaker 10.8 17 20 --------------- HKSX05XC - 208 V 17.3 26 30 --------------- HKSX06XC - 208 V 21.7 31 35 --------------- HKSX08XC - 208 V 28.9 40 40 --------------- HKSX10XC - 208 V 34.7 47 50 --------------- HKSC05XC - 208 V Breaker 17.3 26 30 --------------- HKSC08XC - 208 V 28.9 40 40 --------------- HKSC10XC - 208 V 34.7 47 50 --------------- HKSC15XA - 208 V 34.7 47 50 17.3 22 25 69 70 HKSC19CA - 208 V 34.7 47 50 34.7 43 45 91 100 HKSC15XF - 208 V ^0 4 15 30 38 40 ------ HKSC20XF - 208 V ^0 4 15 38 47 50 ------ HKSX03XC - 240 V No Breaker 12.5 20 20 --------------- HKSX05XC - 240 V 20 29 30 --------------- HKSX06XC - 240 V 25 35 40 --------------- HKSX08XC - 240 V 33.3 46 50 --------------- HKSX10XC - 240 V 40 54 60 --------------- HKSC05XC - 240 V Breaker 20 29 30 --------------- HKSC08XC - 240 V 33.3 46 50 --------------- HKSC10XC - 240 V 40 54 60 --------------- HKSC15XB - 240 V 40 54 60 20 25 25 79 80 HKSC19CB - 240 V 40 54 60 40 50 50 104 110 HKSC15XF - 240 V ^0 4 15 34.6 43 45 ------ HKSC20XF - 240 V ^0 4 15 43 54 60 ------ SS-GARUF www.goodmanmfg.com 11 Heat Kit Data (cont.) See notes on page 12. Heater Kit Model Circuit 1 Circuit 2 Single-Point Kit Amps MCA¹MOP²Amps MCA¹MOP²MCA¹MOP² ARUF49D14AC 0/0 4/4 15/15 --------------- HKSX03XC - 208 V No Breaker 10.8 18 20 --------------- HKSX05XC - 208 V 17.3 26 30 --------------- HKSX06XC - 208 V 21.7 31 35 --------------- HKSX08XC - 208 V 28.9 40.5 45 --------------- HKSX10XC - 208 V 34.7 48 50 --------------- HKSC05XC - 208 V Breaker 17.3 26 30 --------------- HKSC08XC - 208 V 28.9 40.5 45 --------------- HKSC10XC - 208 V 34.7 48 50 --------------- HKSC15XA - 208 V 34.7 48 50 17.3 22 25 69 70 HKSC20DA - 208 V 34.7 48 50 34.7 43 45 91 100 HKSC15XF - 208 V ^0 4 15 30 38 40 ------ HKSC20XF - 208 V ^0 4 15 38 47 50 ------ HKSX03XC - 240 V No Breaker 12.5 20 20 --------------- HKSX05XC - 240 V 20 29 30 --------------- HKSX06XC - 240 V 25 36 40 --------------- HKSX08XC - 240 V 33.3 46 50 --------------- HKSX10XC - 240 V 40 54 60 --------------- HKSC05XC - 240 V Breaker 20 29 30 --------------- HKSC08XC - 240 V 33.3 46 50 --------------- HKSC10XC - 240 V 40 54 60 --------------- HKSC15XB - 240 V 40 54 60 20 25 25 79 80 HKSC20DB - 240 V 40 54 60 40 50 50 104 110 HKSC15XF - 240 V ^0 4 15 34.6 43 45 ------ HKSC20XF - 240 V ^ 0 4 15 43 54 60 ------ ARUF61D14AC 0/0 6/6 15/15 --------------- HKSX03XC - 208 V No Breaker 10.8 19 20 --------------- HKSX05XC - 208 V 17.3 27 30 --------------- HKSX06XC - 208 V 21.7 33 35 --------------- HKSX08XC - 208 V 28.9 42 45 --------------- HKSX10XC - 208 V 34.7 49 50 --------------- HKSC05XC - 208 V Breaker 17.3 27 30 --------------- HKSC08XC - 208 V 28.9 42 45 --------------- HKSC10XC - 208 V 34.7 49 50 --------------- HKSC15XA - 208 V 34.7 49 50 17.3 22 25 71 80 HKSC20DA - 208 V 34.7 49 50 34.7 43 45 92 100 HKSC15XF - 208 V ^0 6 15 30 38 40 ------ HKSC20XF - 208 V ^0 6 15 38 47 50 ------ HKSC25DA - 208 V 52 71 80 35 43 45 114 125 12 www.goodmanmfg.com SS-GARUF Heat Kit Data (cont.) Heating kW Correction Factor Supply Voltage 240 230 220 210 208 Correction Factor 1.00 0.92 0.84 0.77 0.75 Multiply the 240-volt heating capacity by correction factors. ¹ Minimum Circuit Ampacity (Heater Amps + Motor Amps) X 1.25 ² Maximum Overcurrent Protection = 2.25 X Motor Amps + Heater Amps --- indicates Not Required Note : The 208 or 240 in the heat kit part number field is for clarification of the nominal voltage for this model. ^ Three Phase 3 Notation is correct as XB because technically the 240V heater kit application can be used here without any issues. Heater Kit Model Circuit 1 Circuit 2 Single-Point Kit Amps MCA¹MOP²Amps MCA¹MOP²MCA¹MOP² HKSX03XC - 240 V No Breaker 12.5 21 25 --------------- HKSX05XC - 240 V 20 31 35 --------------- HKSX06XC - 240 V 25 37 40 --------------- HKSX08XC - 240 V 33.3 47 50 --------------- HKSX10XC - 240 V 40 56 60 --------------- HKSC05XC - 240 V Breaker 20 31 35 --------------- HKSC08XC - 240 V 33.3 47 50 --------------- HKSC10XC - 240 V 40 56 60 --------------- HKSC15XB - 240 V 40 56 60 20 25 25 81 90 HKSC20DB - 240 V 40 56 60 40 50 50 106 110 HKSC15XF - 240 V ^0 6 15 34.6 43 45 ------ HKSC20XF - 240 V ^0 6 15 43 54 60 ------ HKSC25DB - 240 V 60 81 90 40 50 50 131 150 SS-GARUF www.goodmanmfg.com 13USE COPPER WIRESPEEDUPCOPPER POWER SUPPLY(SEE RATING PLATE)EQUIPMENT GROUNDBLBLSEENOTE 3BKM1BRBRRCEMRDBLBKRDPUWHEBTDRSRBLGRDXFMR-RXFMR-CCRRDGRSEE NOTES 2 & 6BLRDGRWHBR5NOCOMNCK1K1PUPURDRDCBKBRPLFBK1RDPU2324024V4123TRRDSEENOTE 4BLBR45WH6789PLMGRND1BK23RDL2L14567890140A00242-APLMPLFTRFACTORY WIRINGFIELD WIRINGNOTES:TIME DELAY RELAYSTRAIN RELIEFEVAPORATOR MOTORELECTRONIC BLOWERRUN CAPACITORSREMEBTDRRCBKRDBLYLBLUEBLACKREDYELLOWCOMPONENT CODEBROWNPURPLEGREENPUBRGRFEMALE PLUG CONNECTORMALE PLUG CONNECTORTRANSFORMER HIGH VOLTAGE LOW VOLTAGE HIGH VOLTAGE LOW VOLTAGEPLF32COLOR CODERDTRWH6BR5PLM4424V5SEE NOTE 1123RCHIEMGRWIRING CODEBLEBTDRLOCOMNCM1EBTDRNO208/240VOLTS11PLFPLML1PLM2L2(M2)PURC(M1)BKBLMEDIUM3 SPEEDBRHIGHEM(COM)RDLOWIF REPLACEMENT OF THE ORIGINAL WIRESSUPPLIED WITH THIS ASSEMBLY IS NECESSARYUSE WIRE THAT CONFORMS TO THENATIONAL ELECTRIC CODE.M2PU(TR 1)M2RGCEBTDRSEE NOTE 1FLFUSE LINKTLTHERMAL LIMITSEE NOTE 5RRELAYTERMINAL BLOCK SHOWNFOR 50HZ MODELS ONLYTHREE SPEED MOTOR WIRING(SELECT MODELS ONLY)SEE NOTE 3WHITEWHUSE MIN. 75°C FIELD WIRE1. RED WIRES TO BE ON TRANSFORMER TERMINAL "3" FOR 240 VOLTS AND ON TERMINAL "2" FOR 208 VOLTS.2. SEE COMPOSITE WIRING DIAGRAMS IN INSTALLATION INSTRUCTIONS FOR PROPER LOW VOLTAGE WIRING CONNECTIONS.3. CONFIRM SPEED TAP SELECTED IS APPROPRIATE FOR APPLICATION. IF SPEED TAP NEEDS TO BE CHANGED, CONNECT APPROPRIATE MOTOR WIRE (RED FOR LOW, BLUE FOR MEDIUM, AND BLACK FOR HIGH SPEED) ON "COM" CONNECTION OF THE EBTDR. INACTIVE MOTOR WIRES MUST BE CONNECTED TO "M1 OR M2" ON EBTDR.4. BROWN AND WHITE WIRES ARE USED WITH HEAT KITS ONLY.5. EBTDR HAS A 7 SECOND ON DELAY WHEN "G" IS ENERGIZED AND A 65 SECOND OFF DELAY WHEN "G" IS DE-ENERGIZED.6. LOW VOLTAGE FIELD WIRING TO BE N.E.C CLASS 2 WIRES.GRNDGROUNDSEE NOTES 2 & 6Wiring Diagram – Air Handler Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring.⚠ WarningHigh Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death.⚡¹ Minimum Circuit Ampacity (Heater Amps + Motor Amps) X 1.25 ² Maximum Overcurrent Protection = 2.25 X Motor Amps + Heater Amps --- indicates Not Required Note : The 208 or 240 in the heat kit part number field is for clarification of the nominal voltage for this model. ^ Three Phase 3 Notation is correct as XB because technically the 240V heater kit application can be used here without any issues. 14 www.goodmanmfg.com SS-GARUFWiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring.⚠ WarningHigh Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death.⚡Wiring Diagram – Three-Phase Heater Kit RCBRBREM35214RDTRWHBRBKL2L1RDRDBLBKPUBLPURELAY/SEQUENCERTHERMAL LIMITTRANSFORMERRUN CAPACITORELEC. BLOWER TIME DELAY RELAYEVAPORATOR MOTORHEAT ELEMENTHTREBTDREMRSTLTRRCCOMPONENT CODE24 VOLTTRRCEMEBTDREBTDRCOMNONC208/240 VOLTS0140M00273-AWHBKGNDL3T3CCL2L1BLT2T1RBLRDBRM3M4PUM2PUWHM1WHWHRSBLWHPUBLRD123578964WHPCEBTDRTERMINAL BLOCKCONTACTOR9-PIN CONNECTORPCCCTBM2RSM1M 3M 4L1L2LOWHIGHCCHEATER CONTROLAR POWER SUPPLY123456789PC(CIRCUIT 1)NCSPEEDUPGRCRDXFMR-RXFMR-CM1COMK1NOK1L1RDGRPKBLPUSRSTRAIN RELIEFM1YL YELLOWBK BLACKBL BLUEBR BROWNGR GREENOR ORANGEPK PINKPU PURPLERD REDWH WHITECOLOR CODE(CIRCUIT 2)HKR POWER SUPPLYL1L2L3FLSRFUSE LINKW2W1WBRGRBLPKGRCRDT1T2T312345FLHTR3TLFLHTR2TLFLHTR1TLTLFLHTR3TLFLHTR2TLFLHTR1CB CIRCUIT BREAKERL1L2L3BKBKBKBKBKBKBKBKBKBKBKBKBKBKBKBKBKBKBKWIRING CODEHIGH VOLTAGELOW VOLTAGEBKNOTE: WHEN INSTALLING HEATER KIT, ENSURE SPEED TAP MUST EXCEED OR EQUAL THE MINIMUM BLOWER SPEED (MBS)SPECIFIED FOR THE AIRHANDLER/HEATER KIT COMBINATION ON THIS UNIT'S SERIAL PLATE.AFTER INSTALLING OPTIONAL HEAT KIT, MARK AN "X" IN THE PROVIDED BELOW.NO MARK INDICATES NO HEAT KIT INSTALLED.NOTE:-THIS LABEL MUST BEATTACHED ON THEAIRHANDLER IN A PROMINENTLOCATIONBKRDTBL1L2CIRCUIT 11 PH 208-240VCIRCUIT 23 PH. 208-240V SS-GARUF www.goodmanmfg.com 15 Accessories Expansion Valve Kits for Air Conditioning and Heat Pump Applications Kit Number Description Application Refrigerant Tonnage: Outdoor Unit TX2N4A Non-bleed Valve AC or HP R-410A 1½ - 2 Ton TX3N4 Non-bleed Valve AC or HP R-410A 2½ - 3 Ton TX5N4 Non-bleed Valve AC or HP R-410A 3½ - 5 Ton Downflow Insulation Kit DFK-B DFK-C DFK-D ARUF25B14**ARUF37C14**ARUF37D14** ARUF29B14**ARUF43C14**ARUF43D14** ARUF31B14**ARUF49C14**ARUF47D14** ARUF49D14** ARUF61D14** Filters Chassis Part #Size B ALFH16201E 16.0” x 20.0” C ALFH1912201E 19.5” x 20.0” D ALFH20231E 23.0” x 20.0” Single Point Wiring Kit (SPW-01) Heater Kit Model SPWK-B SPWK-C SPWK-D HKSC15XA- 208 V ARUF31B14**ARUF37C14** ARUF43C14** ARUF49C14** ARUF37D14** ARUF43D14** ARUF47D14** ARUF49D14** ARUF61D14** HKSC15XB- 240 V HKSC19CA- 208 V HKSC19CB- 240 V HKSC20DA- 208 V ARUF37D14** ARUF43D14** ARUF47D14** ARUF49D14** ARUF61D14** HKSC20DB- 240 V ARUF37C14** HKSC25DA- 208 V ARUF61D14**HKSC25DB- 240 V Drain Port Plug Kit Number Description Application DPK1 Side Drain Port Plug All Models 16 www.goodmanmfg.com SS-GARUF Goodman Manufacturing Company, L.P., reserves the right to discontinue, or change at any time, specifications or designs without notice or without incurring obligations. © 2021 Goodman Manufacturing Company, L.P. • Houston, Texas • Printed in the USA. Notes