Loading...
830 SAILFISH DR RES20-0194 BLOWER DOOR & TERMITE 511Pr*At Pest Raiders AL, an Arrow Exterminators'company Certificate of Compliance Location of Property: 3O � �► 1 X15 Street Name: VAI (-`s h (� City and State: /► 4,G 'Pgr h) Date of Treatment: � c/cI J O p2 2. Chemical Used: (1Pinn St n,GS�fo The above-referred property has received a complete termite treatment for the prevention of subterranean termites. This treatment is with accordance with rules and laws established by the Florida Department of Agriculture and Consumer Services. v Certified 9uerator Signature Date Lee Hartin Service Center Manager Nader's Pest Raiders P.O.Box 1758-Ponte Vedra Beach,FL 32004-922 8'"Ave.S.-Jacksonville Beach,FL 32250 Office:904-395-0130 Envelope Leakage Test Report (Blower Door Test) Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: Permit# -- U /91, Job Information Builder: Community: Lot: NA Address: 830 Sailfish Dr City: Atlantic Beach State: FL Zip: 32233 Air Leakage Test Results Passing results must meet either the Performance, Prescriptive, or ERI Method O PRESCRIPTIVE METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour at a pressure of 0.2 inch w.g. (50 Pascals)in Climate Zones 1 and 2. ERFORMANCE or ERI METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding e selected ACH(50)value, as shown on Form R405-2017(Performance)or R406-2017(ERI),section labeled as infiltration,sub-section ACH50. ACH(50)specified on Form R405-2017-Energy Calc(Performance)or R406-2017(ERI): 6.500 /' / OC/ x 60 = 15678 = Method for calculating building volume: CFM(50) Building Volume A (50) O Retrieved from architectural plans PASS •Code software calculated When ACH(50) i less than 3, Mechanical Ventilation installation O Field measured and calculated must be verified by building department. R402.4.1.2 Testing.Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g. (50 Pascals). Testing shall be conducted by either individuals as defined in Section 553.993(5)or(7), Florida Statues.or individuals licensed as set forth in Section 489.105(3)(f), (g), or(i)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to thecode official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1. Exterior windows and doors,fireplace and stove doors shall be closed, but not sealed, beyond the intended weatherstripping or other infiltration control measures. 2. Dampers including exhaust. intake, makeup air, back draft and flue dampers shall be closed, but not sealed beyond intended infiltration control measures. 3. Interior doors, if installed at the time of the test.shall be open. 4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5. Heating and cooling systems, if installed at the time of the test,shall be turned off. 6. Supply and return registers, if installed at the time of the test,shall be fully open. Testing Company Company Name: PI/ S7`-2/2 �i)2r� Phone: 90'/ 3 ioo7 I hereby verify that-the above Air Leak results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according . •-compliance method selected above. Signature of Tester: APIP rr _ Date of Test: 2Z Printed Name of Tester: 41°J.- ' Ore License/Certification #: C 4 CJ'xpg3 Issuing Authority:FR 7/8/2020 6:39:32 PM EnergyGauge®USA 6.0.02(Rev. 1)-FlaRes2017 FBC 6th Edition(2017)Compliant Software Page 1 of 1