Loading...
2389 Mayport Rd Fire Sprinkler Inspection Report (2)C. Are all fire protection systems in service? No Monthly Quarterly Annual Third Year Fifth Year 613 N.W. MERCANTILE PLACE PORT ST. LUCIE, FL 34986 772-878-3350 • FAX: 772-878-5967 3226 CHERRY PALM DRIVE TAMPA, FL 33619 81 3-630-0303 • FAX: 81 3 -630-0312 11326 DISTRIBUTION AVENUE WEST JACKSONVILLE, FLORIDA 32256-2745 904-268-3030 - FAX: 904-268-0724 4683 LAREDO AVENUE FORT MYERS, FLORIDA 33905 239-433-3030 - FAX: 239-433-3263 4370 MOTORSPORT DRIVE CONCORD, NORTH CAROLINA 28027 704-782-3032 - FAX: 704-795-6838 222 CAPITOL CT. OCOEE, FL 34761-3033 407-656-3030 - 407-656-8026 3121 NW 16TH TERRACE POMPANO BEACH, FLORIDA 33064 954-917-3030 - FAX: 954-917-9424 NFPA-25 Inspection, Testing and Maintenance of Wet Pipe Fire Sprinkler Systems Information on this form covers the minimum requirements of NFPA 25-2008 for fire sprinkler systems connected to distribution systems without supplemental tanks or fire pumps. Separate forms are available to inspect, test and maintain fire pumps, water tanks and other fire protection systems. More frequent inspection, testing and maintenance may be necessary depending on the conditions of the occupancy and the water supply. All responses refer to the current work (inspection, testing and maintenance) performed on this date. This work is (check one): Part I - Owner's Section 4. Annual Inspection Items (in addition to above items)A. Is the building occupied? A. Proper number and type of spare sprinklers?B. Has the occupancy classification and hazard of contents remained the same since the last inspection? E. Was the system free of actuation of devices or alarms since the last inspection? G. AlI deficiencies reported at last inspection corrected? H. I know the location and understand the operation of all control valves. Owner or representative (print name)SignaturePart II - Inspector's Section A. Inspections 1. Daily and Weekly Items A. Control valves supervised with seals in correct (open or closed) position? B. Backflow Preventers: 1. Valves in correct (open or closed) position? Yes D. Has the system remained in service without modification since the last inspection? NoYes NoYes NoYes NoYes NoYes NoYes Yes No N/A Yes No N/A Yes No N/A Yes No N/A Yes No N/A 2. Sealed, locked or supervised & accessible? 3. Relief port on RPZ device not discharging? C. For freezer systems, is the gauge near the compressor reading the same as the gauge near the dry-pipe valve? 2. Monthly Inspection Items (in addition to above items) A. Control valves with locks or electrical supervision in correct (open or closed) position?Yes No N/A B. Sprinkler wrench with spare sprinklers?Yes No N/A C. Gauges on wet-pipe system in good condition and showing normal water supply pressure?Yes No N/A D. Alarm Valves: Gauges show normal supply water pressure, free from physical damage, valves in correct (open or closed) position and no leakage from retarding chamber or drains?Yes No N/A 3. Quarterly Inspection Items (in addition to above items) A. Pressure Reducing Valve: In open position, not leaking, maintaining downstream pressure per design criteria, and in good condition with handwheels not broken? B. Hydraulic nameplate (calculated systems) securely attached to riser and legible?Yes No C. Fire Department Connection: Visible, accessible, couplings and swivels not damaged and rotate smoothly, plugs or caps in place and undamaged, gaskets in place and in good condition, identification sign(s) in place, check valve is not leaking, clapper is in place and operating properly and automatic drain valve in place and operating properly?Yes No N/A (If plugs or caps are not in place, inspect interior for obstructions.) D. Alarm devices free from physical damage?Yes No N/A Yes No N/AB. Visible sprinklers: 1. Free of corrosion and physical damage?Yes No N/A 2. Free of obstructions to spray patterns?Yes No N/A 3. Free of foreign materials including paint?Yes No N/A 4. Liquid in all glass bulb sprinklers?Yes No N/A C. Visible pipe: 1. In good condition/no external corrosion?Yes No N/A 2. No mechanical damage and no leaks? Yes No N/A3. Properly aligned and no external loads? D. Visible pipe hangers and seismic braces not damaged or loose?Yes No N/A E. Hose, hose couplings and nozzles on sprinkler system passed inspection in accordance with NFPA 1962? G. Has an internal inspection of the pipe been performed by removing the flushing connection and one sprinkler near the end of a branch line within the last 5 years? (If the answer was "No", conduct an internal inspection.) 5. Fifth Year Inspection Items (in addition to above items) A. Alarm valves and their associate strainers, filters and restriction orifices passed internal inspection? B. Check valves internally inspected and all parts operate properly, move freely and are in good condition? B.Testing The following tests are to be performed at the noted intervals. Report any failures on Part III of this form. 1. Quarterly Tests A. Mechanical water flow alarm devices passed tests by opening the inspector's test connection or bypass connection with alarms actuating and flow observed?Yes No N/A B. Post indicating valves opened until spring or torsion is felt in the rod, then closed back one-quarter turn?Yes No N/A C. Main drain test for system downstream of backflow or pressure reducing valve: 2. Was flow observed?Yes No N/A 3. Are results comparable to previous test?Yes No N/A 2. Semiannual Test (in addition to previous items) A. Valve supervisory switches indicate movement?Yes No N/AB. Electrical waterflow alarm devices passed tests by opening the inspector's test connection or bypass connection with alarms actuating and flow observed?Yes No N/A 3. Annual Test (in addition to previous items) A. Main drain test: 3. Are results comparable to previous test? 2. Was flow observed?Yes No N/A Yes No N/A B. Are all sprinklers date 1920 or later? C. Fast response sprinklers 20 or more years old replaced or successfully sample tested within last 10 years? Owner: Owner's Address: Property Being Evaluated: Property Address: Date of Work: SITE#:CALL#: Owner's Phone Number: 1. Record Static Pressure psi and Residual Pressure psi 1. Record Static Pressure psi and Residual Pressure psi Unable to determine.Yes No NIC Yes No N/A NIC Yes No N/A Date See comments - on page 2 See comments - on page 2 NoYes N/AJ. I would like to have a copy of NFPA#25 @ an extra charge of $50.00.NoYes NoNICYes N/A NoNICYes N/A NoNICYes F. Weekly logs of inspections required by NFPA#25 on file? Yes No NoYes Not installed Design criteria is not available K. Owner or rep. requests WAFS to release information from NoYes inspections to the underwriters of my insurance company. Owner or Owner rep. not on site. BEST WESTERN MAYPORT INN & SUITES 2389 MAYPORT ROAD ATLANTIC BEACH, FL. 32233 BEST WESTERN MAYPORT INN & SUITES 2389 MAYPORT ROAD ATLANTIC BEACH, FL. 32233 Mar 16, 2022 608714 904)435-3500 40 30 Mar 16, 2022Thomas Huss Wet Pipe Report page 2 D. Standard response sprinklers 50 or more years old replaced or successfully sample tested within last 10 years? E. Standard response sprinklers 75 or more years old replaced or Part III - Comments (any "No" answers, test failures or other problems found with the sprinkler system must be explained here. All items that need repaired or replaced are the owners responsibility and are not included in the price of inspection. Part IV - Observations: Not a part of the NFPA-25 inspection, the following items may need to be reviewed by a fire protection engineer. Part IV - Inspector's Information I state that the information on this form is correct at the time and place of my inspection and that all successfully sample tested within last 5 years? F. Dry-type sprinkler replaced or successfully sample tested within last 10 years? G. Specific gravity of antifreeze correct?Yes No N/A H. All control valves operated through full range and returned to normal Yes No N/Aposition? I. Backflow devices passed backflow test? J. Backflow devices passed full flow test? K. Pressure reducing valves passed partial flow test?4. Test to be done every third year: Hose (more than 5 years old) connected to the system has been service tested in accordance with NFPA 1962. Water discharged and water flow alarms operated? 5. Test to be done every 5th year A. Sprinklers rated aboveHigh temperature tested? B. Gauges checked by calibrated gauge or replaced?Yes No C. Pressure reducing valves passed full flow test? C. Maintenance 1. Regular Maintenance Items A. If sprinklers have been replaced, were they proper replacements? B. Used hose was cleaned, drained and dried before being placed back in service? Hose exposed to hazardous materials was disposed of or decontaminated in an approved manner? C. Systems normally filled with fresh water were drained and refilled twice if raw water got into the system? D. If any of the following were discovered, was an obstruction investigation conducted? Explain reason(s) and obstruction investigation finding in Part III 1. Defective intake screen on pump with suction from open sources. 2. Obstructive material discharged during water flow tests. 3. Foreign materials found in dry-pipe valves, check valves or pumps. 4. Foreign material in water during drain test or plugging of inspector's test connection. 5. Plugging of pipe or sprinklers found during activation or alteration. 6. Failure to flush yard piping or surrounding public mains following new installation or repairs. 7. Record of broken mains in the vicinity. 8. Abnormally frequent false-tripping of dry-pipe valves. 9. System is returned to service after an extended period out of service (greater than one year). 10. There is reason to believe the system contains sodium silicate or its derivatives or highly corrosive vluxes in copper pipe systems. E. If conditions were found that required flushing, was flushing of system conducted? 2. Annual Maintenance Items (in addition to previous items) A. Operating stem of all OS&Y valves lubricated completely closed, and reopened?Yes No N/A B. Sprinklers and spray nozzles protecting commercial cooking equipment and ventilating systems replaced except for bulb-type which show no signs of grease buildup?Yes No N/A 3. Regular Maintenance Items A. Alarm panel clear?Yes No N/A B. System left in service?Yes No N/A equipment tested at this time was left in operational condition upon completion of this inspection except as noted in Part III above. Date: Signature of Inspector: License or Certification Number (if applicable): C. Is system impaired? (Impairment program put into place per NFPA-25 and Wayne Automatic Fire Sprinklers protocols)Yes No NIC Yes No N/A NIC Yes No N/A Provisions not provided. Provisions not provided. Yes NoNIC Yes NoNIC NoNICYes N/A NoNICYes N/A NoNICYes N/A NoNICYes N/A NoNICYes N/A Cannot be determined. NoYes Cannot be determined. NoYes NoNICYes N/A NoNICYes N/A No Cannot be determined. Yes N/A Print Name: The scope of work preformed does not include a review of fire sprinkler or fire alarm system design. Color of tag placed on system: RedGreen CALL#: Which systems are Red Tagged If red & green are used: Mar 16, 2022 FPI-17000027 T AILSTOCK 608714