42 East Coast Drive TREE22-0007 03.25.2022 NOIPERMIT #: TREE22-0007
ADDRESS:42 East Coast Drive
APPLICANT:GPS Holdings Group INC
PHONE:904 588 4538
EMAIL:deraz12@gmail.com
CATEGORY DBH 8" - 13.9"# OF TREES INCHES OWED DBH 14" - 29.9"# OF TREES INCHES OWED DBH 30"+# OF TREES INCHES OWED TOTAL INCHES
REMOVED PRESERVATION CREDIT TOTAL OWED
OAK 0
and/or
-$
ARITIME SPECIES
and/or
PALM 39 45.5
Cabbage 13* (trees in ROW)2*39 (1:1.5)and/or
Cabbage 13 1 6.5 6,825.00$
OTHER
and/or
39 45.5
and/or
6,825.00$
CATEGORY INCHES # OF TREES STAFF NOTES PROPOSED- PLANT PROPOSED- PAY CATEGORY INCHES # OF TREES STAFF NOTES FINAL- PLANT FINAL- PAY
OAK OAK
MARITIME SPECIES MARITIME SPECIES
PALM 48 PALM
Cabbage 12 4
OTHER OTHER
TOTALS 48
TREES REMOVED
PROPOSED MITIGATION FINAL MITIGATION
VACANT LOT
MITIGATION RATIOS: (inches removed : inches replaced)
DBH 8" -13.9"= 1: 0.5
DBH 14" - 29.9" = 1: 0.5
DBH 30"+ = 1:1
Status in accordance with the City of Altantic Beach code of ordinances in effect at the time of application submittal.
APPROVDED
DENIED
TPO ADMINISTRATOR DATE
ADDITIONALINFORMATION:
•The current tree fund rate is $150.00 per inch.
•One shade tree shall be planted or preserved within the required front yard of every lot.
PLANTING REQUIRMENTS
•Oaks must be replaced with oaks and have a 4" caliper and 12' tall at time of planting.
•Maritime Species must be replaced with Maritime Species.
•Mininum 2" caliper for non oaks and 10' tall at time of planting.
•Palms may replace plams.Mininum 8ft clear trunk height at time of planting.
3/17/22X
42 East Coast Drive
TREE22-0007
NEW CONSTRUCTION
T5- removed by JEA, no mitigation
E A S T C O A S T D R I V EA H E R N S T R E E T
90' WEST 6' X 2' WOOD FENCE20' NORTH
TREE BARRICADE TYP.
PALMS TO BE PRESERVED
LIMB UP TO 8' CLEAR TRUNK
TREE BARRICADE TYP.
PALMS TO BE PRESERVED
LIMB UP TO 8' CLEAR TRUNK
4 SP
7 MC
END OF 6' X 2' WOOD FENCE
23 CONFEDERATE JASMINE
36" ESPALIER MIN 3 GAL
FULL 4'OC. MATCHED
*PLANT LIST LEGEND:N-NATIVE, FYN- FLORIDA YARDS & NEIGHBORHOODS 2006, FF- FLORIDA FRIENDLY, WW- WATER WISE 2008,
OHE - JEA OVERHEAD ELECTRIC (ACCEPTABLE PLANT LIST)
SOD ALL 4:1 SLOPES OR GREATER, 10' FROM EOP AND ALL DISTURBED ROW. COORDINATE FURTHER GRASSING WITH GENERAL CONTRACTOR
SOD PASPALUM NOTATUM "ARGENTINE BAHIA" - TSA FREE (WEED FREE)
SELECTED SOD SPECIES MEETS ALL CURRENT LANDSCAPE AND IRRIGATION REQUIREMENTS. ANY VARIABLE WILL REQUIRE GOVERNMENT APPROVAL
PALM TO BE PRESERVED W/ BARRICADE
TREE TO BE REMOVED
LEGEND
PALM TO BE PRESERVED W/ BARRICADE
SHRUB PLANTING DETAIL
E A S T C O A S T D R I V EA H E R N S T R E E T
M
SYMBOL MANUFACTURER/MODEL QTY ARC PSI GPM RADIUS
Two Rain Bird 1401 bubbler 4 x2 360 30 2 x .25 3'
SYMBOL MANUFACTURER/MODEL/DESCRIPTION QTY
Rain Bird 1812 with GPH Irrigation Products GDFN 1
Area to Receive Dripline
Rain Bird XFD-09-12 30 s.f.
In-Line Pressure Compensating Landscape Dripline with
Built-In Check Valve. 1.0GPH emitters at 12.0" O.C.
Dripline laterals spaced at 16.0" apart, with emitters offset
for triangular pattern. Install dripline on both sides of plant material.
SYMBOL MANUFACTURER/MODEL/DESCRIPTION QTY
Hunter NODE-BT-100-VALVE in a 12" Valve Box 1
Install SC-PROBE in landscape area
Wilkins 975XL 1" Backflow Preventer 1
Water Meter 3
4" (by others)1
Irrigation Lateral Line: PVC Class 160 30 l.f.
Irrigation Mainline: PVC Schedule 40 1" 20 l.f.
Pipe Sleeve: PVC Schedule 40
IRRIGATION CONTRACTOR SHALL BE RESPONSIBLE FOR THEIR OWN TAKE OFF
M
IRRIGATION_SCHEDULE
UNDERGROUND IRRIGATION SPECIFICATIONS
B. Installation of Plastic Pipe:
1. Install plastic pipe in a manner to provide for expansion and contraction as recommended by
Manufacturer.
2. Unless otherwise indicated on Drawings, install main lines with a minimum cover of eighteen (18")
inches based on finish grade. Install lateral lines with a minimum cover of twelve (12") inches
based on finish grade
3. Locate no sprinkler head closer than twelve (12") inches from building foundation. Heads
immediately adjacent to mowing strips, walks or curbs shall be one (1") inch below top of
mowing strip, walk or curb and have a minimum of one (1") inch clearance between head and
mowing strip, walk or curb.
4. Drawings show arrangement of piping. Should local conditions necessitate rearrangement, obtain
approval of Landscape Architect prior to proceeding with work.
5. Cut plastic pipe square. Remove burrs at cut ends prior to installation so unobstructed flow will
result.
6. Make solvent weld joints in the following manner:
a. Clean mating pipe and fitting with clean, dry cloth and apply one (1) coat of P-70 primer to
each.
b. Apply uniform coat of 711 solvent to outside of pipe.
c. Apply solvent to fitting in similar manner.
d. Reapply a light coat of solvent to pipe and quickly insert into fitting.
e. Give pipe or fitting a quarter turn to insure even distribution of solvent and make sure pipe
is inserted to full depth of fitting socket.
f. Hold in position for fifteen (15) seconds minimum or long enough to secure joint.
g. Wipe off solvent appearing on outer shoulder of fitting.
h. Do not use an excessive amount of solvent thereby causing an obstruction to form on the
inside of pipe.
i. Allow joints to set at least 24 hours before applying pressure to PVC pipe.
7. Tape threaded connection with teflon tape.
C. Control Valves and Controller:
1. Install controller, control wires, and valves in accordance with Manufacturer's recommendations
and according to applicable electrical code.
2. Install valves in plastic boxes with reinforced heavy duty plastic covers. Locate valve box tops at
finish grade.
3. Install remote control valves in valve boxes positioned over valve so all parts of valve can be
reached for service. Set cover of valve box even with finish grade.
4. Install all valve boxes over nine (9") inches of gravel for drainage.
D. Sprinkler Heads:
1. Prior to the installation of sprinkler heads, open control valves and use full head of water to flush
out system.
2. Set sprinkler heads perpendicular to finish grade.
3. Set lawn sprinkler heads adjacent to existing walks, curbs, and other paved areas to grade.
E. Dripline:
1. Install RD-12-NP drip zone indicator head next to each control valve with closed nozzle.
2. Stake dripline every eight feet along dripline laterals.
3.3 ADJUSTMENT AND CLEANING:
A. Adjust heads to proper grade when turf is sufficiently established to allow walking on it without
appreciable harm. Such lowering or raising of of heads shall be part of the original contract with no
additional charge to the Owner.
B. Adjust sprinkler heads for proper distribution and trim to ensure spray does not fall on building.
C. Adjust watering time of valves to provide proper amounts of water to all plants.
3.4 DEMONSTRATION:
A. After system is installed and approved, instruct Owners Representative in complete operation and
maintenance.
END OF SECTION
1.0 GENERAL
1.1 SUMMARY: Includes but not limited to:
A. Furnishing and installing sprinkler system as described in Contract Documents complete with
accessories necessary for proper functioning.
1.2 SYSTEM DESCRIPTION:
A. Design Requirements:
1. Layout of Irrigation Heads:
a. Location of heads shown on Drawings is approximate. Actual placement may vary slightly as
is required to achieve full, even coverage without spraying onto buildings, sidewalks,
fences, etc.
1.3 QUALITY ASSURANCE:
A. Regulatory Requirements:
1. Work and materials shall be in accordance with latest rules and regulations, and other applicable
state or local laws. Nothing in Contract Documents is to be construed to permit work not
conforming to these codes.
B. Pre-Installation Conference:
1. Meet with Owner and Landscape Architect to discuss and clarify all aspects of job requirements
prior to commencing work of this Section.
C. System Adjustments:
1. Minor adjustments in system will be permitted to avoid existing fixed obstructions.
2. Mainline, laterals, and valves are shown for clarity purposes only. All irrigation equipment to be
with landscape area. Mainline, laterals and valves to be installed as far away from existing and
new specimen trees as possible.
D. 1. Documentation and submittal of actual water supply performance prior to commencing installation.
1.4 SUBMITTALS:
A. Record Drawings:
1. Prepare an accurate as-built drawing as installation proceeds to be submitted prior to final
inspection. Drawing shall include:
a. Detail and dimension changes made during construction.
b. Significant details and dimensions not shown in original Bidding Documents.
2. Maintain, at job site, one copy of Contract Documents (as defined in General Conditions) and
relevant shop drawings.
3. Clearly mark each document "PROJECT RECORD COPY" and maintain in good condition for use of
the Landscape Architect and Owner.
4. As-built drawing shall be clearly drawn.
5. Submit product literature for all sprinklers, valves, pipe, wire, wire connectors and controller.
6. Final payment for system will not be authorized until accurate and complete submittals are
delivered to the Landscape Architect.
B. Instruction Manual:
1. Provide instruction manual which lists complete instructions for system operation and
maintenance.
1.5 PRODUCT STORAGE:
A. During construction and storage, protect materials from damage and prolonged exposure to sunlight.
1.6 WARRANTY:
A. Standard one (1) year warranty stipulated in General Conditions shall include:
1. Completed system including parts and labor.
2. Filling and repairing depressions and replacing plantings due to settlement of irrigation trenches
for one (1) year following final acceptance.
3. System adjustment to supply proper coverage to areas to receive water.
1.7 MAINTENANCE:
A. Extra Materials:
1. In addition to installed system, furnish Owner with the following items at close-out:
a. Two sprinkler head bodies of each size and type.
b. Two nozzles for each size and type.
c. Two adjusting keys for each sprinkler head cover type.
2.0 PRODUCTS:
2.1 PIPE, PIPE FITTINGS, AND CONNECTIONS:
A. Pipe shall be continuously and permanently marked with Manufacturer's name, size, schedule, type,
and working pressure.
B. Pipe:
1. Pressure Lines: as indicated on plans.
2. Lateral Lines: as indicated on plans.
3. Risers: sch. 80 PVC, gray
C. Fittings:
1. Schedule 40 PVC.
D. Sleeving:
1. Schedule 40 PVC.
2.2 SPRINKLER HEADS:
A. Conform to requirements shown on Drawings as to type, radius of throw, pressure, and discharge.
2.3 AUTOMATIC SPRINKLER SYSTEM:
A. Control valves shall be of size and type indicated on Drawings.
B. Control wire shall be UL listed, color coded copper conductor direct burial size 14. Use 3M-DBY
waterproof wire connectors at splices and locate all splices within valve boxes. Use white or gray color for
common wire and other colors for all other wire.
2.4 VALVES:
A. Electric Valves:
1. Make and model shown on Drawings.
B. Automatic Controller:
1. Make and model shown on Drawings.
2.5 VALVE ACCESSORIES:
A. Valve Boxes:
1. Ametek or Brooks heavy duty valve box with locking lid or Landscape Architect
approved equal.
2. Do not install more than one (1) valve in a single box.
3. Valve boxes shall be large enough for easy removal or maintenance of valves.
3.0 EXECUTION:
3.1 PREPARATION:
A. Protection:
1. Work of others damaged by this Section during course of its work shall be replaced or repaired
by original installer at this Section's expense.
3.2 INSTALLATION:
A. Trenching and Backfilling:
1. Over-excavate trenches by two (2") inches and bring back to indicated depth by filling with fine,
rock-free soil or sand.
2. Cover pipe both top and sides with two (2") inches of material specified in paragraph above. In
no case shall there be less than two (2") inches of rock-free soil or sand surrounding pipe.
HUNTER PROS-12 WITH GDFN
PVC EXHAUST MANIFOLD, OR DRIPLINE
16" MAX. SPACING
SHRUB HEDGE
DRIPLINE TO BE INSTALLED UNDER MULCH LAYER
SUPPLY LINE
PVC SUPPLY MANIFOLD, INSTALLED BELOW GRADE
DRIPLINE START CONNECTION MALE ADAPTER
DIPLINE LAYOUT
SCALE: NTS
FINISH GRADE
UNDISTURBED/STABILIZED SOIL
SURFACE WITH SOIL STAPLES
LATERAL LINE PVC PIPE TO
BUBBLER, 18" DEPTH
K FLEX
PLANT TO BE IRRIGATED,
SEE IRRIGATION PLANS
PCT BUBBLER, LOCATE WITHIN
SAUCER
2 - 180° APART
PLANTING SAUCER,
CONTINUOUS
EACH BUBBLER INDIVIDUALLY
TIED INTO FLEX PIPE
K FLEX PIPE
SECURE K FLEX AND BUBBLERS TO SOIL
NOTES:
1. BUBBLERS SHALL BE PLACED ON THE UPHILL SIDE OF ANY SLOPES & ON THE
OPPOSING SIDES OF EACH ROOTBALL WITHIN THE SAUCER
2. BUBBLERS TO BE INSTALLED ADJACENT TO ROOTBALL PERIMETER, DO NOT
INSTALL BUBBLER ON TOP OF ROOTBALL OR NEXT TO TRUNK
3. REFER TO PLANS FOR BUBBLER FLOW VOLUME AND BUBBLER QUANTITIES
PER TREE OR PALM
IRRIGATION DETAIL
BUBBLER APPLICATION
DETAIL LEGEND:
12
11
2
3
9
10
7
68
HUNTER IRRIGATION CONTROLLER
(NODE-BT) AND MOUNTING
HARDWARE PER PLAN
HUNTER SOIL MOISTURE PROBE
(SC-PROBE) INSTALLED AT 50% OF
ROOT DEPTH
SC-PROBE CABLE TO CONTROLLER
HUNTER VALVE PER PLAN
VALVE BOX PER PLAN
MAIN LINE PER PLAN
MAIN LINE RISER PER PLAN
1
2
3
4
5
6
LATERAL LINE PER PLAN
GRAVEL BASE, DEPTH AS
SPECIFIED
FILTER FABRIC
BRICK
FINISHED GRADE
8
9
10
11
7
5
12
1 4
IRRIGATION DETAIL
NODE BT
From:Richardson, Christopher C.
To:Genest, Abrielle
Date:Tuesday, March 15, 2022 10:10:57 AM
TY
Christopher C Richardson Sr.
JEA
Overhead Electrical Coordinator
Richcc@jea.com 904-665-4317
From: Genest, Abrielle <agenest@coab.us>
Sent: Tuesday, March 15, 2022 10:08 AM
To: Richardson, Christopher C. <RichCC@jea.com>
Subject: RE: 304 Ahern St
[External Email - Exercise caution. DO NOT open attachments or click links from unknown
senders or unexpected email.]
Thank you. You are approved to remove a tree.
From: Richardson, Christopher C. [mailto:RichCC@jea.com]
Sent: Tuesday, March 15, 2022 9:54 AM
To: Genest, Abrielle <agenest@coab.us>
Subject: FW: 304 Ahern St
Christopher C Richardson Sr.
JEA
Overhead Electrical Coordinator
Richcc@jea.com 904-665-4317
From: Richardson, Christopher C. <RichCC@jea.com>
Sent: Tuesday, March 15, 2022 9:38 AM
To: 'Agenest@coab.net' <Agenest@coab.net>
Cc: Richardson, Christopher C. <RichCC@jea.com>; Vilchez, Federico A. - Mgr Energy Construtction
and Maint <vilcfa@jea.com>; Theodoridis, Constantine <TheoC@jea.com>
Subject: 304 Ahern St
Due to customer plans we need to remove a single palm tree in order to set a 55’ wood pole out
of parking area. With your permission we will take it down to accomplish this. Tree is a single palm
30 plus feet from the corner of east
Coast Dr. on Ahern St…
Thanks,
Christopher C Richardson Sr.
JEA
Overhead Electrical Coordinator
Richcc@jea.com 904-665-4317
Want to receive City of Atlantic Beach news by email? Just say so in an email to
info@coab.us. Follow the City of Atlantic Beach on Facebook at
www.facebook.com/cityofatlanticbeach. Florida has a very broad public records law. Most
written communications to or from state and local officials and agencies regarding state or
local business are public records available to the public and media upon request. Your email
communications, including your email address, may therefore be subject to public disclosure.