41 CORAL ST ROOF22-0020 Building Permit Application Updated 10/9/18 1.. City of Atlantic Beach Building Department **ALL INFORMATION 800 Seminole Road, Atlantic Beach, FL 32233 HIGHLIGHTED IN GRAY Phone: (904) 247-5826 Email: Building-Dept@coab.us IS REQUIRED. Job Address: 41 Coral St, Atlantic Beach, FL 32233 Permit Number: ' \CO E L ' C)/(DZCD 15-82 09-2S-29E.505/OCEAN GROVE UNIT NO 1 S/D PT LOT 7/LOTS 7,13,14,15 BLK 8 Legal Description RE# 169593-0000 Valuation of Work(Replacement Cost)$20,500.00 Heated/Cooled SF Non-Heated/Cooled_ • Class of Work: ❑New ❑Addition ❑Alteration ❑Repair ❑Move ❑Demo ❑Pool ❑Window/Door • Use of existing/proposed structure(s): ❑Commercial ❑Residential • If an existing structure, is a fire sprinkler system installed?: ❑Yes ❑No • Will tree(s) be removed in association with proposed project? ❑Yes(must submit separate Tree Removal Permit) ❑No Describe in detail the type of work to be performed: Remove existing roof and install new Carlisle Seamless HS silicone roof system and curb mount skylights Florida Product Approval# see attached product approval sheet for multiple products use product approval form Property Owner Information SHEPARD HERSCHEL E JR ET AL/SHEPARD HERSCHEL E III 3`l INT R/S Name Address 41 Coral St City Atlantic Beach State FL Zip 32233 Phone (904) 249-9040 E-Mail hnjshepard@comcast.net Owner or Agent(If Agent, Power of Attorney or Agency Letter Required) Contractor Information Name of Company White's Roofing Company, Inc .Qualifying Agent Timothy White Address 3742 Golden Reeds Ln City Jacksonville State FL Zip_32224 Office Phone (9041220-5546 Job Site Contact Number State Certification/Registration# CCC 058017 E-Mail_ whitesroofing@att.net Architect Name& Phone# Engineer's Name& Phone# Workers Compensation Insurer FRSA OR Exempt E Expiration Date Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all the laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING,SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS,TANKS,and AIR CONDITIONERS,etc. NOTICE: In addition to the requirements of this permit,there may be additional restrictions applicable to this property that may be found in the public records of this county,and there may be additional permits required from other governmental entities such as water management districts,state agencies,or federal agencies. OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR ATTORNEY BE RE RECORDING YOUR NOT CE OF COMMENCEMENT. ilkfAdet (Signature of 0 ner or Agent) (Signature of Contractor) IA- Signed and sworn to(or affirmed) before me this Z� day of Signed and sworn to(or affirmed) before me this�� day of AA I , 2—( 2Z , by }-ter-5d^e,l ,5%,,epa,-f qov l , 202Z, by -Ti t -14.y W b'i-1-- d-(-Q w. ' LSl-Aira/`&,-u---t t---- !Nor\eKke} .S kj 0 ••-A (Signature of Nota ) (Signature ofoN tary) \\\\Y P',, ANDREA J. LEPIANKA ' ANDREA J. LEPIANK \\11111(, 4: vB� Notary Public-State of Florida r.0,114e,-: r .•- �.Notary Public-State of Flor I [ ]Personally Known OR "' - Commission # HH 28779 [ Personally Known OR /uu _' `` —�•_ Commission # HH 2877 Produced Identification % '`'off,' My Commission ExpiresProduced Identification =;!` ,ro= (SCJ [ I ,,_ \e My Commission Expire Y Type of Identification: August 05, 2024 Type of Identification: "1 11\` August 05, 2024 ,--- art ve./s 1 cense Doc # 2022100155, OR BK 20233 Page 449, Number Pages: 1, Recorded 04/20/2022 02:16 PM, JODY PHILLIPS CLERK CIRCUIT COURT DUVAL COUNTY RECORDING $10.00 NOTICE OF COMMENCEMENT (PREPARE IN DUPLICATE) Permit No. Tax Folio No. State of Florida County of Duval To whom it may concern: The undersigned hereby informs you that improvements will be made to certain real property,and in accordance with Section 713 of the Florida Statutes,the following information is stated In this NOTICE OF COMMENCEMENT. Legal description of property being improved: 15-82 09-2S-29E.505 OCEAN GROVE UNIT 1 S/D PT LOT 7 LOTS 7,13,14,15 BLK 8 Address of property being improved: 41 Coral St,Atlantic Beach, FL 32233 General description of improvements: Complete roof replacement Owner Herschel E Shepard Jr ET AL, Herschel E Shepard III 3% INT R/S Address 41 Coral St,Atlantic Beach, FL 32233 Owner's interest in site of the improvement Fee Simple Titleholder(if other than owner) Name Address Contractor White's Roofing Company, Inc Address 3742 Golden Reeds Lane,Jacksonville,FL 32224 Phone No. (904)220-5546 Fax No. Surety(if any) Address Amount of bond$ Phone No. Fax No. Name and address of any person making a loan for the construction of the improvements. Name Address Phone No. Fax No. Name of person within the State of Florida,other than himself,designated by owner upon whom notices or other documents may be served: Name Address Phone No. Fax No. In addition to himself,owner designates the following person to receive a copy of the Lienor's Notice as provided in Section 713.06(2)(b),Florida Statutes.(Fill in at Owner's option). Name Address Phone No. Fax No. Expiration date of Notice of Commencement(the expiration date is one(1)year from the date of recording unless a different date is specified): THIS SPACE FOR RECORDER'S USE ONLY ��// OWNER Signed: rI/til C/ /4 t} ^^ DATE OC{I au I Z 2 Before me this 2O.N. day of_ l 2022. In the County of Duval,State of Florida,has rsonally appeared1,-t{P/.• C..4 . S� ax 0.geherein by kmaelfaarself and affirms that all statements an w.fir w.wc AIN are true and accurateF.. ANDREA J. LEPIANKA c� NotarymmissionSPublictaate of Florida_ •; CoHH 26779 '-?• My Commission Expires "iP,,,^" August 05,2024 Awn e-e— ��"yam la�(�• Notary Public at Large,State of Florida . county or Duval My commission expires: Auqust 5,2024 Personally Known or Produced Identification Driver's License siliwtr) sys-k-rn NEMO I etc. Certificate of Authorization#32455 353 Christian Street, Unit#13 Oxford,CT 06478 (203)262-9245 ENGINEER EVALUATE TEST CONSULT EVALUATION REPORT Carlisle Roof Foam and Coatings Evaluation Report 3m-CRL-21-FBCER.A 100 Enterprise Drive FL37994-R1 Cartersville, GA 30120 Date of Issuance:06/15/2021 (770)607-0755 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code. The product described herein has been evaluated for compliance with the 7th Edition(2020) Florida Building Code sections noted herein. DESCRIPTION: SeamlesSEALTM,SeamlesSEALTM'ULTRA and RoofTiteT"Roof Coatings LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s)changes,the referenced Quality Assurance or production facility location(s) changes, or Code provisions that relate to the product(s) change. Acceptance of our Evaluation Reports by the named client constitutes agreement to notify NEMO ETC, LLC of any changes to the product(s), the Quality Assurance or the production facility location(s). NEMO ETC, LLC requires a complete review of its Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Florida Product Approval Number (FL#) preceded by the words "NEMO'etc. Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 6. Prepared by: ...............,•,, r7srE /if Robert J.M. Nieminen, P.E. • • The facsimile seal appearing was authorized by Robert .•,ao; N�_ ,,off Florida Registration No.59166,Florida DCA ANE1983 ��..,,,,,,,,,.+ Nieminen,P.E,on 06/15/2021. This does not serve as an electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. NEMO ETC,LLC is not owned,operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E.does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E.are,in any way,the Designer of Record for any project on which this Evaluation Report,or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. ©2018,NEMO ETC,LLC $NEMOIetc. ROOFING COMPONENT EVALUATION: 1. SCOPE: Product Category: Roofing Sub-Category: Cements—Adhesives-Coatings Compliance Statement: SeamlesSEAL,SeamlesSEAL ULTRA and RoofTite Roof Coatings, as produced by Carlisle Roof Foam and Coatings, have demonstrated compliance with the following sections of the 7th Edition (2020) Florida Building Code through testing in accordance with the Standards set forth herein. Compliance is subject to the Installation Requirements and Limitations/Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1507.10.2,1507.14.3,R905.9.2, Material standard ASTM D6083 2018 R905.11.2,R905.14.3, 1523.6.2.1.1,1523.6.5.2.12.2, TAS 110 1507.14.3,1507.15.2, Material standard ASTM D6694 2013 R905.14.3,R905.15.2,TAS 110 1523.6.2.1.1 Wind driven rain TTC-555B 1973 3. REFERENCES: Entity Examination Reference Date NEMO(TST6049) ASTM D6083 4j-CRL-21-SSLAP-01.A 06/14/2021 PRI(TST5878) ASTM D6083 2231T0010 02/02/2021 PRI(TST5878) ASTM D6694 TRS-032-02-01,TRS-036-02-01 03/11/2014 PRI(TST5878) ASTM D6694 TRS-033-02-01,TRS-036-02-01, 05/16/2014 TRS-039-02-01 PRI(T5T5878) TTC-555B PSP-004-02-01,PSP-010-02-01 11/21/2014 PRI(TST5878) TTC-555B PSP-003-02-01,PSP-009-02-01 11/24/2014 PRI(TST5878) ASTM D6694 ACLA-007-02-01 05/21/2019 PRI(TST5878) ASTM D6694(partial) 2231T0005 06/09/2021 INTERTEK(TST1558) ASTM D6694(partial) K9879.01-106-18 01/11/2021 UL,LLC(QUA 9625) Quality Control Service Confirmation 06/07/2021 4. PRODUCT DESCRIPTION: I The following SeamlesSEAL, SeamlesSEAL ULTRA and RoofTite Roof Coatings are acceptable for use in any roof system approval or—for roof coatings—any fire rating directory listing, which refers to the specific product or to the codified ASTM designation for the product. TABLE 1A:EVALUATED COATINGS Product Material Plant(s) Approved Use Standard SeamlesSEAL Acrylic ASTM D6083, Phoenix,AZ 100%acrylic,single-component,water-based,elastomeric Type Icoating SeamlesSEAL HT ASTM D6083, 100%acrylic,single-component,water-based,high tensile Acrylic Type I Phoenix,AZ strength,elastomeric coating RoofTite Acrylic ASTM D6083, Phoenix,AZ 100%acrylic,single-component,water-based,elastomeric Type Icoating RoofTite HIT Acrylic ASTM D6083, Phoenix,AZ 100%acrylic,single-component,water-based,high tensile Type Istrength,elastomeric coating SeamlesSEAL ULTRA ASTM D6694 Cartersville,GA Single-component,moisture-cured,fluid-applied silicone coating LS Silicone NEMO ETC,LLC Evaluation Report 3m-CRL-21-FBCER.A Certificate of Authorization#32455 7T"EDITION(2020)FBC NON-HVHZ&HVHZ EVALUATION FL37994-R1 SeamlesSEAL and RoofTite Roof Coatings Revision 0:06/15/2021 Page 2 of 6 NEMO etc. TABLE 1A:EVALUATED COATINGS Product Material Plant(s) Approved Use Standard SeamlesSEAL ULTRA ASTM D6694 Cartersville,GA Single-component,moisture-cured,high-solids,fluid-applied HS Silicone silicone coating SeamlesSEAL ULTRA ASTM D6694 Cartersville,GA Single-component,moisture-cured,fluid-applied silicone coating HSLV Silicone that is formulated to meet low-VOC requirements Roof-rite LS Silicone ASTM D6694 Cartersville,GA Single-component,moisture-cured,fluid-applied silicone coating RoofTite HS Silicone ASTM D6694 Cartersville,GA Single-component,moisture-cured,high-solids,fluid-applied silicone coating RoofTite HSLV ASTM D6694 Cartersville,GA Single-component,moisture-cured,fluid-applied silicone coating Silicone that is formulated to meet low-VOC requirements TABLE 1B:SUBSTRATE TREATMENTS&PRIMERS Product Material Plant(s) Approved Use Standard Prime-Tek Bleed Block Primer N/A Phoenix,AZ Water-based primer for use over asphaltic surfaces Prime-Tek Epoxy Two-component,1-to-1 ratio,thixotropic,water-based epoxy Primer N/A Brookfield,WI primer Prime-Tek N/A Houston,TX Low-viscosity,sprayable liquid used to pre-treat EPDM and Membrane Cleaner other roof membranes prior to pressure washing Prime-Tek TPO II Low-VOC,solvent-based primer designed to promote adhesion Primer N/A Walpole,MA to new or existing TPO membrane. 5. LIMITATIONS: 5.1 This is a building code evaluation. Neither NEMO ETC,LLC nor Robert Nieminen,P.E.are,in any way,the Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report pertains to above-deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. 5.3 This Evaluation Report does not include evaluation of fire classification. Refer to FBC 1505 or FBC HVHZ 1516 for requirements and limitations regarding roof assembly fire classification. Refer to FBC 2603 for requirements and limitations concerning the use of foam plastic insulation. 5.4 SeamlesSEAL, SeamlesSEAL ULTRA and RoofTite Roof Coatings are components for use in Approved roof assemblies. Refer to the "Approved Use" in Section 4 for each component. The coatings noted herein are not purported to be Roofing Systems,and their use shall be governed by and limited to applications where Roof System Product Approval is not necessary(e.g.,maintenance and repair)or where the components are called out in a Roof System Product Approval. 5.5 All products listed herein shall have quality assurance audit in accordance with F.A.C.Rule 61G20-3 requirements. NEMO ETC,LLC Evaluation Report 3m-CRL-21-FBCER.A Certificate of Authorization 1131455 71"EDITION(2020)FBC NON-HVHZ&HVHZ EVALUATION FLY/994-R1 SeamlesSEAL and RoofTite Roof Coatings Revision 0:06/15/2021 Page 3 of 6 NEMO etc. 6. INSTALLATION: 6.1 SeamlesSEAL,SeamlesSEAL ULTRA and RoofTite Roof Coatings shall be installed in accordance with Carlisle Roof Foam and Coatings installation instructions,subject to the Limitations in Section 5 and the Approved Use noted in Section 4. 6.2 Allowable Substrates: Unless otherwise noted, noted substrates may be new or existing. TABLE 2:ALLOWABLE SUBSTRATES SEAMLESSEAL ACRYLIC OR ROOFTITE ACRYLIC Substrate* Treatment Primer Base Coat Finish Coat Concrete,structural N/A N/A 1.5 gal/sq. 1.5 gal/sq. Metal,galvanized steel N/A N/A 1.5 gal/sq. 1.5 gal/sq. Single Ply,existing,PVC N/A Prime-Tek TPO II Primer 1.5 gal/sq. 1.5 gal/sq. Single Ply,existing,TPO N/A Prime-Tek TPO II Primer 1.5 gal/sq. 1.5 gal/sq. Spray polyurethane foam N/A N/A 1.5 gal/sq. 1.5 gal/sq. (SPUF) *Note: Existing roof system and/or substrate shall meet wind uplift requirements of the project to the satisfaction of the Authority Having Jurisdiction. TABLE 3:ALLOWABLE SUBSTRATES SEAMLESSEAL HT ACRYLIC OR ROOFTITE HT ACRYLIC Substrate* Treatment Primer Base Coat Finish Coat Concrete,structural N/A N/A 1.5 gal/sq. 1.5 gal/sq. Metal,galvanized steel N/A N/A 1.5 gal/sq. 1.5 gal/sq. Single Ply,existing,TPO N/A Prime-Tek TPO II Primer 1.5 gal/sq. 1.5 gal/sq. Spray polyurethane foam N/A N/A 1.5 gal/sq. 1.5 gal/sq. (SPUF) *Note: Existing roof system and/or substrate shall meet wind uplift requirements of the project to the satisfaction of the Authority Having Jurisdiction, TABLE 4:ALLOWABLE SUBSTRATES SEAMLESSEAL ULTRA LS SILICONE OR ROOFTITE LS SILICONE Substrate* Treatment Primer Application Built-Up Roof,existing, asphaltic,granule surfaced N/A Prime-Tek Epoxy Primer Minimum total thickness of 18 TDM(total dry mil) Built-Up Roof,existing, asphaltic,smooth-surfaced N/A Prime-Tek Epoxy Primer Minimum total thickness of 18 TDM(total dry mil) Concrete,structural N/A N/A Minimum total thickness of 22 TDM(total dry mil) Metal,galvanized steel N/A N/A Minimum total thickness of 18 TDM(total dry mil) Metal,existing,coated N/A N/A Minimum total thickness of 18 TDM(total dry mil) Modified Bitumen,existing, APP,granule surfaced N/A Prime-Tek Epoxy Primer Minimum total thickness of 18 TDM(total dry mil) Modified Bitumen,existing, N/A Prime-Tek Epoxy Primer Minimum total thickness of 18 TDM(total dry mil) APP,smooth-surfaced Modified Bitumen,existing, SBS,granule surfaced N/A Prime-Tek Epoxy Primer Minimum total thickness of 18 TDM(total dry mil) Modified Bitumen,existing, SBS,smooth-surfaced N/A Prime-Tek Epoxy Primer Minimum total thickness of 18 TDM(total dry mil) NEMO ETC,LLC Evaluation Report 3m-CRL-21-FBCER.A Certificate of Authorization#32455 7TM EDITION(2020)PBC NON-HVHZ&HVHZ EVALUATION F137994-R1 SeamlesSEAL and RoofTite Roof Coatings Revision 0:06/1.5/2021 Page 4 of 6 NEMO f etc. TABLE 4:ALLOWABLE SUBSTRATES SEAMLESSEAL ULTRA LS SILICONE OR ROOFTITE LS SILICONE Substrate* Treatment Primer Application Single Ply,existing,CSPE Prime Tek Prime-Tek Epoxy Primer Minimum total thickness of 18 TDM(total dry mil) Membrane Cleaner Single Ply,existing,EPDM Prime Tek Prime-Tek Epoxy Primer Minimum total thickness of 18 TDM(total dry mil) Membrane Cleaner Single Ply,existing,PVC Prime-Tek Prime-Tek Epoxy Primer Minimum total thickness of 18 TDM(total dry mil) Membrane Cleaner Spray polyurethane foam N/A N/A Two(2)coats for a minimum total thickness of 20 (SPUF) TDM(total dry mil) *Note: Existing roof system and/or substrate.shall meet wind uplift requirements of the project to the satisfaction of the Authority Having Jurisdiction. TABLE 5:ALLOWABLE SUBSTRATES SEAMLESSEAL ULTRA HS SILICONE OR ROOFTITE HS SILICONE Substrate* Treatment Primer Application Built-Up Roof,existing, asphaltic,granule surfaced N/A Prime-Tek Epoxy Primer Minimum total thickness of 18 TDM(total dry mil) Built-Up Roof,existing, asphaltic,smooth-surfaced N/A Prime-Tek Epoxy Primer Minimum total thickness of 18 TDM(total dry mil) Concrete,structural N/A N/A Minimum total thickness of 22 TDM(total dry mil) Metal,galvanized steel N/A N/A Minimum total thickness of 18 TDM(total dry mil) Metal,existing,coated N/A N/A Minimum total thickness of 18 TDM(total dry mil) Modified Bitumen,existing, APP,granule surfaced N/A Prime-Tek Epoxy Primer Minimum total thickness of 18 TDM(total dry mil) Modified Bitumen,existing, APP,smooth surfaced N/A Prime-Tek Epoxy Primer Minimum total thickness of 18 TDM(total dry mil) Modified Bitumen,existing, SBS,granule surfaced N/A Prime-Tek Epoxy Primer Minimum total thickness of 18 TDM(total dry mil) Modified Bitumen,existing, SBS,smooth surfaced N/A Prime-Tek Epoxy Primer Minimum total thickness of 18 TDM(total dry mil) Single Ply,existing,CSPE Prime Tek Prime-Tek Epoxy Primer Minimum total thickness of 18 TDM(total dry mil) Membrane Cleaner Single Ply,existing,EPDM Prime Tek Prime-Tek Epoxy Primer Minimum total thickness of 18 TDM(total dry mil) Membrane Cleaner Single Ply,existing,PVC Prime Tek Prime-Tek Epoxy Primer Minimum total thickness of 18 TDM(total dry mil) Membrane Cleaner Spray polyurethane foam N/A N/A Two(2)coats for a minimum total thickness of 20 (SPUF) TDM(total dry mil) *Note: Existing roof system and/or substrate shall meet wind uplift requirements of the project to the satisfaction of the Authority Having Jurisdiction. NEMO ETC,LLC Evaluation Report 3m-CRL-21-FBCER.A Certificate of Authorization#32455 7T"EDITION(2020)FBC NON-HVHZ&HVHZ EVALUATION i SeamlesSEAL and RoofTite Roof Coatings Revision 0:06/15/2021 Page 5of 6 NEMo 1 etc. TABLE 6:ALLOWABLE SUBSTRATES SEAMLESSIEAL ULTRA HSLV SILICONE OR ROOFTITE HSLV SILICONE Substrate* Treatment Primer Application Concrete,structural N/A N/A One(1)or two(2)coats for a minimum total thickness of 22 TDM(total dry mil) Modified Bitumen,existing, (Optional)Prime-Tek APP,granule surfaced N/A Bleed Block Minimum total thickness of 18 TDM(total dry mil) Modified Bitumen,existing, (Optional)Prime-Tek SBS,granule surfaced N/A Bleed Block Minimum total thickness of 18 TDM(total dry mil) Modified Bitumen,existing, (Optional)Prime-Tek SBS,smooth-surfaced N/A Bleed Block Minimum total thickness of 18 TDM(total dry mil) Prime-Tek Single Ply,existing,EPDM Membrane Cleaner N/A Minimum total thickness of 18 TDM(total dry mil) Single Ply,existing, Prime-Tek N/A Minimum total thickness of 18 TDM(total dry mil) CSPE/Hypalon Membrane Cleaner Single Ply,existing,TPO Prime Tek Prime-Tek TPO II Primer Minimum total thickness of 18 TDM(total dry mil) Membrane Cleaner Spray polyurethane foam N/A N/A Two(2)coats for a minimum total thickness of 20 (SPUF) TDM(total dry mil) *Note: Existing roof system and/or substrate shall meet wind uplift requirements of the project to the satisfaction of the Authority Having Jurisdiction. 7. BUILDING PERMIT REQUIREMENTS: I As required by the Building Official or Authority Having Jurisdiction to properly evaluate the installation of this product. 8. MANUFACTURING PLANTS: I I Contact the named QA entity for manufacturing facilities covered by F.A.C.Rule 61G20-3 QA requirements. Refer to Section 4 herein for products and production locations having met codified material standards. 9. QUALITY ASSURANCE ENTITY: UL, LLC.—QUA9625; (613)371-2765,Jacob.Stewart@ul.com -END OF EVALUATION REPORT- NEMO ETC,LLC Evaluation Report 3m-CRL-21-FBCER.A Certificate of Authorization#32455 7'"EDITION(2020)FBC NON-HVHZ&HVHZ EVALUATION Fl37994-R:l SeamlesSEAL and RoofTite Roof Coatings Revision 0:06/15/2021 Page 6 of 6 t a 4 7 INSTALLATION INSTRUCTIONS d'- Sun-Tek Manufacturing,Inc. GLASS SERIES Engineer of Record: .P,4'4„,!;',..'.'‘.',..,krwe �7 7} _��� 0303 General Drive James D.Wells,Jr.,P.E. Sun-Tek Orlando,FL 32824 MODEL CMG" Skylights cus/mer5e 17 Florida Professional Engineer wwwsun-tek.com Use on any type roof!curb required) No.53616 ,; s wwwsun-tek.com \ \-... "r+ SIZE INFORMATION Fastenersdsedule '---- J&L Wells Finished Model CMG i.r Opening Only Fits on Fastener \\ -1'. ' Consulting LLC .' Size Roof (Drywall Curb Outside Center Per Tops Fattener Code Opening DsmensioN Dimension Spacing Bottom Per Side 1345 Unit'Court -�-�-- . 1414 1119x115" 105'x 1055' 145•x 14th• 16' 3 3 Casselberry,FL 327071422 P.,'x 19," 10',-x 18`r' 14'3'x 221/2 16' 3 3 1430 114i'x 275' 105x5' ' 26'6• 14x305• 16' 3 3 (407)496-5489 s',..,.,_,,„.. ata x4,r os,x4z'' ae' 16 3 4 I.4--CURB OA.-0.1 Certificate of 1725 145x225' 13n x 2159 17Wx 2514' 16' 3 3 Authorization No.27162 1749 143,"x 6W 14 45.9 17 ..59'-:' 3 4 ��\ ,� 1749 1415 x465' 1354 x455' 7744 x4954' 16' 3 4 1 0IOWsening - 2212 191h",1914' I8 18•,' 27 x 72'', 24- 3 3 1 k 7230 1ovfr27x' 1659x265' 225'x305' 24' 3 3 . S 114E 19"1i-x43x,' 181,"x42'," 22`,',403.. 24 3 4 man 01wNg e 2269 195'x661' 1859x6514' 2259.6919 24' N/A N/A 2525 224"x 22', 21'-.x 21'.4 29-e'x 25X," 24 3 3 CLEANING YOUR SKYLIGHT: STS 1000 Caulk•Use only between decking and underside of skylight flange on 2533 225'x305' 2114'x295' 255',3314' 24' 3 3 You will need. c Use a mild so and watts orglass cleaner only 1 splashes,glazing 2549 2Yh"x 46'6" 21',4 x 45"4 2514'x 491,' '4 5 4 •hammer •sealensure alp y pain pa 9 classic seri,..,. 2572 2Z!5•x 699,1• 2754-x6845` 25'h'x 7241' 24' N/A N/A •keyhole saw •tape measure compound,etc.may be removed by rubbing lightly with a soft cloth or cotton ba soaked in mineral spirits. 3030 27,4"x 2T:' 206"x 26!'4 301/2",30',' 10 or 3:' 2 •skill saw •chalkllne or straight edge ACCESSORIES: Step Flesh Kit•Pre-formed,precut flashing eliminates need for flashing on self built 3046 275'x435' 35",'.QK• 30",'r 69', 1',4,32" 3 4 •nails •trowel or caulk gun Skyllghf9ades-a variety of sizes are available and are easily installed.Contact your rurh.Use with selected sires Model CMG.Note Step flash kit designed for use with 3069 27 u6''," 16','x65'., su 9; 1-'ser 32 v;n \rA •drill •utility knife building materials dealer or Sun'Tek Manufacturing for details. curbs constructed of 2 x 4's only. 3333 305 x 3019 295"x 295' 33'4 x 3319 16 or 32' 3 3 •2 x 4's 3349 • 30 " 46!," 29/,""x 4s`•:' 33., 451 h' 1 r"1" 4 4646 435•x435' eV/x425' 469'c465i" 16 or 24'or 48' 4 4 Fp[LIgbiTTtalnet; RECOMMENDED SEALANTS: LIGHT TUNNEL INSTALLATION INSTRUCTIONS 4669 43x,"x 6655' '3'5'42x 6911.,1 46'1-x 6954 16 or 24'or 48" N/A VA •8 or 10 penny nails •Non-hardening roof cement 4949 465'x465' . 45x454' 495•x495' 16"or 24'or48' 4 4 •plywood or drywall •Butyl rubber sealant/caulk For homes with an attic.it is necessary to build a tunnel between skylights and ceiling.The tunnel walls may be straight,or flared for extra light and 5576 52V,"x 731/2" StVI',72'54 Ss.r'x 731/2 '3,, n A •STS 1000(Stan-Tek exclusive) architectural appeal.It's very easy to increase the tunnel size along the length of the ceiling joists.As long as no roof-supporting members are cut,no special framing is needed.While it is possible to flare the tunnel in all directions,if support members are cut.special framing will be required for structural FAILURE TO FOLLOW RECOMMENDED INSTALLATION PROCEDURES MAY VOID WARRANTY I support.In this case you must consult a qualified building professional to insure proper and safe results. 1 After roof and ceiling openings have been framed,measure distance(at each corner of roof Check local building codes for glass requirements.•Please read instructions completely before beginning.•Deck and roofing opening)between rafter/truss and ceiling Joist. felt should already by installed.•Interior wood liner should be stained or painted before installation. Io/ ++2 Using these four measurements,cut 2 x 4 lumber for vertical support members(two per comer). ��, 3 In each corner,nail vertical support members into place at fight angles to each other. ..,.,,\ e'L/ 1 To properly position skylight between trusses/rafters,locate the roof opening \\_ \ Pfr_=_ 4 Measure,cut,and nail tunnel walls into place.Suggestions for lining tunnel: I from the underside of the decking.(If this area is not accessible,locate the '��.�-- + -use drywall,tape corners,and paint white using regular or texture paint.(Texture paint alone • II�� ceiling joists from inside the house,mark opening in ceiling(a-c),and cut \'2 \, �__ will hide and fill untaped joints,but in time,cracks may appear in corners.) \ III ceiling opening.Then follow steps below for roof opening.) \\\ \\ ...mi. use prefinished paneling with molding in corners. -Ilex the tunnel with cedar,pine,or a wood to coordinate with your decor, a) measure distance between trusses/rafters and mark center point. \\\ -for special effects,try painting the tunnel a striking accent color,or use mirrors or wallpaper on b)to center skylight,measure one-half of appropriate roof opening to each f \ _. tunnel walls. _ side of center point and mark. .,� 5 Caulk the slight gap between the tunnel walls and skylight base. \ cl using the side marks as a guide,mark corners by drilling holes or driving _- �r 'W- 1111110.41111h` 5 Finish off tunnel at ceiling with molding,or blend edges into ceiling with texture paint. nails through roof. \\\\\\ 7 Be sure to wrap the exterior of the tunnel with insulation for energy savings. 2 Remove shingles 6-8"out from roof opening. SKYLIGHT LIMITED WARRANTY \ Son-tel.Alarwlactur,,me l',n lel 10202 Gere.Onve .,Ficn420,00 A eS 2.0n, neral,nny tern.ats campm ranw4raae.:Thn rwn.nt.ppWr meanMe on.nal pejo 3 Cut roof opening(snap a chalkline from corner to corner,or draw line with a ,... eon wtoromw tor Son Wood, or.,..ern. ,.�io',.i or rv,.,.w,g A w,...•w+, awe .nem 9he,ta1wawa,n. straightedge. rytM tont OM „ra.rpn°d.u,T<.odu,put toyer,Mt...at M alp outer/210w the en.. ,,gent/plow,tit nowt.Gt Nr Sw.Tel Wu.rr ) ` 11. nmwmu,wrn...porvNnlu ori, m ' - e wRl,�n..p.a t,portion ennk4 , 4 Int° ,5 Frame roof opening: 'a'° 22p'rc^"porcent a) cut two 2 x 4's to fit the actual distance between trusses/rafters and nail c..,,,..1M,adationnt pear.,r°ya;02,10 0onl to Men tenal•knthe t.m.dr,.00zeli,aim 1.twe ode«p.aanr,M.,nounx4cd«er,n.,.rt.....tn<,r.r....ind n........ into lace.NOTE:5ize 2525,2549,3333,3349,4949Skip step"b"proceed C.uurr.0apgkxfan:TN by Str.apProaortowa e,pa,aMhercahm Gine.neat me ea al.prartnany er,hisisr.ri COMM.. threuOtr one rretold rgn Moo., on ate..or:aua,caen,2..,00a p r„m,.pii.er0.ewfop 2.i...0Tet awwgx2,wnant..notOwvpen..f,orrii monGrhmoe.n or renmtmw hreW la c.nxrcmata1n YruininrmanceedAenr.natt,erwlo por.....rm.,11On instage td••fin set�ne,eyx....or.Wrono mawSon s,.mnottxreaponauera umcmnwliniomown w......f...Naeraha.we:To amene.nno of Wm,inn...,°ale.,,,..molt Int On t... ;u yni>�;wnmt:rar„e„•„roar,y,n.,,w,•wsp,yaynr.a.erw.t,r,gcyni,,,,,,,sal,r.,,�perw.e..u...wr.tllNotals„n re.n„.,,mydmt'..n•,�,*.n'.+.,yome.r=au«rtn+a4w,.ane�v,e¢ b)cut two 2 x 4's to the exact length of the roof opening and nail to the ® \ and Ili Sun Timor....on.agars now,exmnnm rM nwy.and dnamneto xi taCartan WNW e,e...n now.br Mt warranty F.Mpg.wwanee.IMN AO WARRANI.1.12x1UUNC.art N'O1 MONO TU:MAW ' .R..xS Ur N221,01rAe0.1tTNN.nNESSHAP PAAT2UUR PUPWriE.5M4Lrrot Exif/08002.10t MRATIONOfTHE EXPRESSWAAPAr.TES PPOY.Dr(RUN.Some beta,do lot allow Wiwi.,mbow 1.9anWOW trusses/rafters. �\ ,.s"oytu.4lnaMW,Cons.pontiol Oarnpu.SUr-1BCar 11.01PFWRFFOR ANT INC riENrAI OA COFISENENTW DAMAGES SVrMT50EVER.C..MNG/Ur,aT LOAM.20 LOSSOrT<on EVENVE,uxwETELEP2aNr OA OT,EPE.PFNus son.st.rt,.not aww ate.mutancclova. 02Intuntwad.n,.°...,l,.t,...,,rr„n0.....sr...on...now not apwy Myna..Emmis c) if applicable,cut ceiling opening and build tunnel framing(See Light Warranty:I,suo ori'.15r,,,000,2.vatwe.,:x,.l0ioiRwARRNNrtE,Tmwarranty,nn„Ta,e,un,0,a0„h2 ra„0.020.ent,,.n,11112121,2 e..,u.e.ua.r.w,e Tunnel Installation Instructions') Intl aa.nauon Information a,-e ,n own Mea em WM..r.omw.orlows to n.ay..wat.ntw of nito result,of any.of mu Wonnaben is to Im Implied.awl o,warow of um ars beyond our,.m,ol. ..,..lout bvudl,e tee.,for Deplane WM.IestauMa. 1283.02-5/09 �f s(oa s • 5 Build curb: —i 14 5/a a)Construct curb with 2 x 4's,2 x 6's,etc.(depending on height desired or .` �— �-1 o.a uiromuu I� —�,' + S building code requirements).Curb should be minimum 3-1/2"high.Be sure .♦ — r I inside measurement of curb is the same as roof opening measurement. , 7''� / b)Secure curb to roof. ` W—=— m n 6 Shingle roof up to bottom of curb. =� 7 Flash curb(sizes 2525,2549,3333, IS • + 3349,4949 can be used with Sun-Tek's preformed,pre-cut Step Flash Kt with L. one-piece head and sill).Use galvanized 4:0_,.41,„ —_—_— " t ----— m sheet metal,aluminum,or copper.Metal � � �b. should extend a minimum of 4''over 10.3%.---- " shingles(on bottom side),then up sides '* - , of curb.Flashing should be flush with Ir\ curb top. 8 Shingle up sides and across the top. el \ 49;49 9 Position the skylight over the curb with \ ,_—'1/4 _ the"THIS EDGE DOWN'label at the lowest side of the curb.Center the skylight ` ♦� r over the curb making sure the foam gasket is in contact with the top of the curb. _`�—� I s, As the fasteners,(see fastener schedule),are being attached to the curb,push ` (a) down on the frame just above the fastener to insure the gasket is compressed `�� to form a good seal.Use the 1 r/."spiral ring shanked nails,provided.Continue attaching the remaining fasteners in the same manner.All fastener installation holes provided must be used —� — THIS EDGE =��` + DOWN OUTBOARD GLASS (TEMPERED) '� �-e� EXTRUDED— • ALUMINUM ALUMINUM \ 1 FRAME ��� ►�� — �^ ARGON FILLED SPACENi INBOARD GLASS 0.- I j� (TEMPERED) • WOOD SHIM -11..„ r (BY OTHERS) S\ I DESIGN PRESSURE RATING _ • i! 1r t90PSF. w z °. NON IMPACT RATED I +s�.s.>r lir #10x2' COARSE CURB THREAD SCREW (BY OTHERS) J&L Wells Consulting LLC 1/4:12 PITCH 1345 Unity Court Casselberry,FL 32707 Engineer of Record: -)Ia��9 (407)496-5489 James I).Wells,Jr.,P.E. Certificate of Authorization No-27162 Florida Professional Engineer No.53616 PRODUCT APPROVAL INFORMATION SHEET FOR THE CITY OF ATLANTIC BEACH, FLORIDA (*REQUIRED) *Project Address: 41 Coral St, Atlantic Beach, FL 32233 Permit#: *Owner/Project Name: Herschel Shepard As required by Florida Statute 553.842 and Florida Administrative Code Rule 61G20-3, please provide the information and product approval number(s) for the building components listed below as applicable to the building construction project for the permit number listed above. You should contact your product supplier if you do not know the product approval number for any of the applicable listed products. Information regarding statewide product approval may be obtained at: www.floridabuilding.org. Category/Subcategory Manufacturer Product Description Limitation of Use State# Local# A.EXTERIOR DOORS 1.Swinging 2.Sliding 3.Sectional 4. Garage Roll-Up 5.Automatic 6. Other B.WINDOWS 1.Single hung 2. Horizontal slider 3.Casement 4. Double hung 5. Fixed 6.Awning 7. Pass-through 8. Projected 9. Mullion 10. Wind breaker 11. Dual action 12. Other Page 1 of 4 Updated 06/21/21 Category/Subcategory Manufacturer Product Description Limitation of Use State# Local# C. PANEL WALL 1.Siding 2.Soffits 3. EIFS 4.Storefronts 5. Curtain walls 6.Wall louvers 7.Glass block 8. Membrane 9.Greenhouse 10.Synthetic stucco 11. Other D. ROOFING PRODUCTS 1.Asphalt shingles 2. Underlayments 3. Roofing fasteners 4. Nonstructural metal roof 5. Built-up roofing 6. Modified bitumen 7.Single ply roofing 8. Roofing tiles 9. Roofing insulation 10.Waterproofing 11.Wood shingles/shakes 12. Roofing slate 13. Liquid applied roofing 14. Cement-adhesive coats 15. Roof tile adhesive 16.Spray applied polyurethane roof 17. Other Carlisle Seamless Silicone system FL37994-R1 Page 2 of 4 Updated 06/21/21 Category/Subcategory Manufacturer Product Description Limitation of Use State# Local# E.SHUTTERS 1.Accordion 2. Bahama 3.Storm panels 4.Colonial 5. Roll-up 6. Equipment 7.Other F.STRUCTURAL COMPONENTS 1. Wood connector/anchor 2.Truss plates 3. Engineered lumber 4. Railing 5. Coolers-freezers 6. Concrete admixtures 7. Material 8. Insulation forms 9. Plastics 10. Deck-roof 11. Wall 12. Sheds 13. Other G.SKYLIGHTS 1.Skylight Sun-Tek curb mount glass skylight FL12626-R10 2.Other H. NEW EXTERIOR ENVELOPE PRODUCTS 1. 2. Page 3 of 4 Updated 06/21/21 In addition to completing the above list of manufacturers, product description and State approval number for the products used on this project, the Contractor shall maintain on the job site and available to the Inspector, a legible copy of each manufacturer's printed specifications and installation instructions along with this Product Approval Sheet. I certify that this product approval list is true and correct to the best of my knowledge. I further certify that use of different components other than the ones listed in this document must be approved by the Building Official. *Contractor Name (Print Name): Timothy White *Contractor Signature: *Company Name: White's Roofing Company, Inc *Mailing Address: 3742 Golden Reeds Ln *City: Jacksonville *State: FL *Zip Code: 32224 *Telephone Number: (904) 220-5546 *E-mail Address: whitesroofing@att.net Cell Phone Number: (904) 333-6663 Fax Number: N/A Page 4 of 4 Updated 06/21/21