Microsoft Word - 45 Simmons RdALPHA SOUTHEAST, INC.
2670 ROSSELLE AVE – SUITE 8
JACKSONVILLE, FL 32204
EVALUATION OF GROUNDWATER TABLE
AT
45 Simmons Road
Atlantic Beach, FL 32233
The purpose of the exploration was to collect information concerning the subsurface
groundwater conditions near the proposed retention area. The evaluation was performed using a
5ft hand-auger. The hand-auger boring was performed at the location shown in the exhibit below.
The initial boring was completed on Tuesday, August 17, 2021 at 11:15am. The boring was
terminated at 3’9’’ below existing ground. 2’’ of water was found at time of boring. The boring
was checked on Wednesday, August 18, 2021 at 11:15am. At time of check 4’’ of water was
found at bottom of hole.
It is anticipated the Seasonal High Groundwater Elevation in the area will normally be at
3’4’’ below the existing ground at the boring location.
Respectfully submitted,
ALPHA SOUTHEAST, INC.
FL C.A. 29643
Reynold D. Peterson, P.E.
Sr Project Manager
FL PE NO 84559
Boring Location
Reynold D.
Peterson
Digitally signed by
Reynold D. Peterson
Date: 2021.10.04
12:29:35 -04'00'
By Toni Gindlesperger at 10:51 am, Jan 21, 2022