Loading...
Microsoft Word - 45 Simmons RdALPHA SOUTHEAST, INC. 2670 ROSSELLE AVE – SUITE 8 JACKSONVILLE, FL 32204 EVALUATION OF GROUNDWATER TABLE AT 45 Simmons Road Atlantic Beach, FL 32233 The purpose of the exploration was to collect information concerning the subsurface groundwater conditions near the proposed retention area. The evaluation was performed using a 5ft hand-auger. The hand-auger boring was performed at the location shown in the exhibit below. The initial boring was completed on Tuesday, August 17, 2021 at 11:15am. The boring was terminated at 3’9’’ below existing ground. 2’’ of water was found at time of boring. The boring was checked on Wednesday, August 18, 2021 at 11:15am. At time of check 4’’ of water was found at bottom of hole. It is anticipated the Seasonal High Groundwater Elevation in the area will normally be at 3’4’’ below the existing ground at the boring location. Respectfully submitted, ALPHA SOUTHEAST, INC. FL C.A. 29643 Reynold D. Peterson, P.E. Sr Project Manager FL PE NO 84559 Boring Location Reynold D. Peterson Digitally signed by Reynold D. Peterson Date: 2021.10.04 12:29:35 -04'00' By Toni Gindlesperger at 10:51 am, Jan 21, 2022