150 2nd St - ROW22-0015 DWGSNO EXPECTED CONFLICTSWITH OTHER UTILITIESLOCATION:150 2ND ST, ATLANTIC BEACH, FL 32233TOTAL LENGTH OF JOB: 264' UGJOB DESCRIPTION: CATV DIRECTIONAL BORE PLACEMENTDRAWN BY: BHUPENDRA S. KANDARIDATE:SCALE: NTS OF 613/30/2022COMCAST PERMIT REQUEST FOR LOCATION:150 2ND ST, ATLANTIC BEACH, FL 32233THESE PLANS WERE PREPARED UNDER THERESPONSIBLE CHARGE OF COMCAST.SANTA ROSAOKALOOSAWALTONHOLMESWASHINGTONBAYCALHOUNJACKSONGADSDENLIBERTYGULFFRAMKLINWAKULLALEONJEFFERSONTAYLORMADISONHAMILTONSUWANNEELAFAYETTEDIXIEGILCHRISTCOLUMBIAUNIONBAKERBRADFORDALACHUALEVYMARIONPUTNAMCLAYDUVALNASSAUST JOHNSFLAGLERVOLUSIALAKESUMTERCITRUSORANGESEMINOLEOSCEOLAPASCOHERNANDOPOLKHILLSBOROUGHPINELLASINDIAN RIVERBREVARDST LUCIEMARTINOKEECHOBEEHIGHLANDSHARDEEMANATEESARASOTADESOTOGLADESCHARLOTTELEEHENDRYPALM BEACHBROWARDCOLLIERMIAMI-DADEMONROEESCAMBIAVICINITY MAP:150 2ND ST, ATLANTIC BEACH, FL 32233DUVAL COUNTYJB972447By Toni Gindlesperger at 11:39 am, May 16, 2022 LOCATION:150 2ND ST, ATLANTIC BEACH, FL 32233TOTAL LENGTH OF JOB: 264' UGJOB DESCRIPTION: CATV DIRECTIONAL BORE PLACEMENTDRAWN BY: BHUPENDRA S. KANDARIDATE:SCALE: NTS OF 623/30/2022NO EXPECTED CONFLICTSWITH OTHER UTILITIESNO BACKREAMER USEDCOMCAST PERMIT REQUEST FORLOCATION:150 2ND ST, ATLANTIC BEACH, FL 32233GENERAL NOTES:ALL PROPOSED UNDERGROUND CATV WILL BE BURIED A MINIMUM OF 36" .ALL PROPOSED UNDERGROUND CATV ROAD BORES WILL USE CITY APPROVED DIRECTIONAL BOREMACHINE, AS WELL AS COUNTY APPROVED CONDUIT.ALL PROPOSED CATV ROAD BORES WILL EXTEND A MINIMUM OF 7' BEYOND THE EDGE OF PAVEMENT.ALL PROPOSED CATV DRIVEWAY BORES WILL EXTEND A MINIMUM OF 6' BEYOND THE EDGE OF PAVEMENT.ALL PROPOSED BORES WILL BE IN A (4'X4'X4') PIT AND WILL USE (2)2" HDPE CONDUIT AT 36" DEPTH EXCEPTROAD BORES AT 48" DEPTH AND DRIVEWAY BORES AT 48" DEPTH USING A 5 1/4" DRILL HEAD.ALL PROPOSED AERIAL WILL BE .700" DIAMETER AND WILL BE LASHED TO .250" STEEL STRAND CABLEUSING .125" STANDARD GALVANIZED LASHING WIRE.ALL PROPOSED AERIAL CATV CROSSING ROAD/WAYS WILL HAVE MINIMUM MID-SPAN HEIGHT OF 18'-0"ALL PROPOSED AERIAL CATV CROSSING DRIVEWAYS WILL HAVE MINIMUM MID-SPAN HEIGHT OF 18'-0"LOCATES WILL BE REQUIRED IN ALL PROPOSED UNDERGROUND AREAS AT LEAST 48 HRS PRIOR TOCONSTRUCTION.NOTIFICATIONS TO ALL UTILITIES INVOLVED WILL BE MADE PRIOR TO CONSTRUCTION.ALL DISTRIBUTED AREA WITHIN THE RIGHT OF WAY WILL BE RESTORED TO ORIGINAL OR BETTERCONDITION BY GRADING AND RE-SODDING. SOD ALL AREAS DISTURBED BY CONSTRUCTION WITHBERMUDA SOD. "ALL CRACKED SIDEWALK IS TO BE REPLACED FROM JOINT TO JOINT WITHIN 7 DAYS OFWORK COMPLETION."WORK OPERATIONS ARE TO BE MINDFUL NOT TO DAMAGE THE PAVER SIDEWALK WHEN POSITIONINGEQUIPMENT. ANY DAMAGE INCLUDING TRACK MARKS WILL BE REPAIRED OR REPLACED BY THECONTRACTOR.CONSTRUCTION NOTES:IN ORDER TO REDUCE THE DISRUPTION AND COST OF UTILITY DAMAGES OCCURRING IN THERIGHT-OF-WAY AND EASEMENTS. THE PERMITTEE SHALL PREVENT DAMAGES TO EXISTING UTILITIESCAUSED BY THE WORK THROUGH FIELD VERIFICATION OF THE LOCATION OF THE EXISTING UTILITIES INCASE OF OPEN EXCAVATION. VERIFICATION MAY BE PERFORMED DURING THE PERMITTEES WORK. IN THECASE OF DIRECTIONAL DRILLING, VERIFICATION SHALL TAKE PLACE PRIOR TO MOBILIZATION OF THEDRILLING EQUIPMENT.THE PERMITTEE SHALL VERIFY THE LOCATION OF THE EXISTING UTILITIES AS NEEDED TO AVOID CONTACTWITH DETECTION EQUIPMENT OR OTHER ACCEPTABLE MEANS, SUCH METHODS MAY INCLUDE BUT SHALLNOT BE LIMITED TO-"SOFT DIG"-EQUIPMENT AND GROUND PENETRATION RADAR (GPR). THE EXCAVATORSHALL BE HELD LIABLE FOR DAMAGES CAUSED TO CITY'S/COUNTIES/STATE INFRASTRURE AND THEEXISTING FACILITIES OF THE OTHER UTILITY COMPANIESNO REAMER USEDTHE FOLLOWING STANDARD PLANS ARE IN ACCORDANCE WITHTHE FLORIDA DEPARTMENT OF TRANSPORTATION 2021-2022INDEX 102-602 & 660 AND APPLY TO:150 2ND ST, ATLANTIC BEACH, FL 32233 LOCATION:150 2ND ST, ATLANTIC BEACH, FL 32233TOTAL LENGTH OF JOB: 264' UGJOB DESCRIPTION: CATV DIRECTIONAL BORE PLACEMENTDRAWN BY: BHUPENDRA S. KANDARIDATE:SCALE: NTS OF 633/30/2022NO BACKREAMER USEDNO EXPECTED CONFLICTSWITH OTHER UTILITIESR/W EOP R/W EOP 40'10'10'20'36'' MIN48'' MINCATVTEL WATER SAN 9'7'5'EOP C/L2ND STTYP ALLOCATION4' S/W4' S/W4' S/W4' S/WGAS/WATER VALVETREE/BUSHESEXISTING PEDESTALEXISTING WATER VAULTEXISTING UTILITY VAULT/PEDESTALSTREET SIGNEOPR/WEOPR/W40'20'10'10'R/WR/WEOPEOP60'20'20'20'2232252221761621421281281361541781502ND ST2ND STOCEAN BLVDD/WD/WD/WD/WD/WD/WD/WEOPR/WEOPR/W40'20'10'10'2'9'1'0+00BEGIN UG HEREEXISTING PED2+64END UG HEREEXISTING PED1+091+70EXISTING PED109'61'94'PROPOSED BORE PLACEMENTFOR 264' ALONG2ND ST & OCEAN BLVDAT MIN DEPTH OF 36"USING 2" 13.5 SDR ROLL PIPEWITH COAXIAL CABLE INSIDER/WR/WEOPEOP20'15'15'50'STREET SIGNPEDPEDPEDPOLEPEDD/WFIRE HYDRANTSTREET SIGNPOLECATCH BASINPOLEUNK MHSTREET SIGNSTREET SIGNBEACH AVE45' ± TOE COAST DR255' ± TO1ST ST170' ± TO3RD ST340' ± TOOCEAN BLVD6'5'10'5'4' S/WR/WEOPR/WEOP50'15'15'20'36'' MIN48'' MINCATVTELWATERSAN 10'8'6'EOP C/LOCEAN BLVDTYP ALLOCATION 6 OF 6 OF 64 OF 65 OF 66