705 ATLANTIC BLVD COMM21-0055 Tenant Build Out Plan_ revision 5-2-22A/C 363 3 New 120/240 Single Phase 200 AMP Service PHOTOCELL SCONCE PHOTOCELL SCONCE A/C W/H A/C MINI SPLIT HANDLER EXTERIOR SIGNAGE WH FEB FEB STORAGESTORAGE1718 15 16 9 9,8 10 13 14 11 12 2,3 5,7 1,3 RESTROOM CLOSET MERCANTILE SPACE SHEET NUMBER:SCOPE OF WORKPROJECT ADDRESS:DATE:SHEET TITLE:SCALESEMINOLE SOUTH LLC2300 Marsh Point RoadSuite 301904 853 6801DESIGNED BYDRAWN BYREVISION # DATESIGNATURE----/Vo lumes /Goog leD r ive /Sha red dr ive s/S ky Rea l E sta te /LOGOS AND LETTERHEADS /Sem ino le Sou th/S em in ole _Logo .pn gSemniole South ROBe-In Bridal Studio Interior Build-Out Permit Set Electrical Plan / Panel Schedule - -20 Seminole RoadAtlantic Beach, FL 322335/17/2022Electrical Plan 3/8"E1Crawford Electric - Jeff Crawford Licence # EC13002649120 / 240 Single Phase 200 AMP By Dan Arlington at 5:37 pm, Jun 08, 2022 2022-Feb-17 09:01:29 Right-Suite® Universal 2021 21.0.11 RSU00000 Page 1 ...SC Builders\Seminole South - 20 Seminole Rd.rup Calc = MN5 Front Door faces: SE Job:Right-Suite® Universal 2021 Short Form Feb 16, 2022Date: System 1 Jonathan JacobsBy: Jonathan Jacobs 146 NE 32nd Ave, Ocala, FL 34470 Phone: 386-503-0449 Email: MechaniCalcs@gmail.com Web: ineedHVACcalcs.com or MechaniCalcsLLC.com Project Information Seminole South LLCFor: 20 Seminole Rd, Atlantic Beach, FL 32233 Htg Clg Htg Clg Outside db 9538(°F)Inside db 7570(°F) Outside RH 43-(%)Inside RH 50-(%) Outside wb 77-(°F)Inside wb 63-(°F) Daily range 16-(°F)Design TD 2033(°F) Moisture diff. 44-(gr/lb) Cooling EquipmentHeating Equipment Make Carrier Make Carrier Model 25HCE460AP0300 Model 25HCE460AP0300 Type Split ASHP Type Split ASHP Efficiency 8.2 HSPF COP / EER / SEER 14.0 Heating Input Sensible Cooling MBtuh38.9 Heating Output MBtuh @ 47°F54.5 Latent Cooling MBtuh10.3 Humidifier gpd5.5 Total Cooling MBtuh49.2 Leaving Air Temp °F70.0 Leaving Air Temp °F55.0 Actual Heating Fan cfm0 Actual Cooling Fan cfm1750 Equipment Location System 1 System Type PEAKCV Fan Motor Heat Type PACKAGE Fan & Motor Combined Efficiency %0 Static Pressure Across Fan in H2O0 NAME Area Heat Sensible Latent Htg Clg Time ft²Loss Gain Gain cfm cfm AH 10 Jul 1500 LDT00362760 Showroom 1090 Jul 1500 LDT17500102923604422762 System 1 1100 22822 36071 10328 0 1750 Jul 1500 LDT 2022-Feb-17 09:01:29 Right-Suite® Universal 2021 21.0.11 RSU00000 Page 2 ...SC Builders\Seminole South - 20 Seminole Rd.rup Calc = MN5 Front Door faces: SE Job:Right-Suite® Universal 2021 Short Form Feb 16, 2022Date: System 2 Jonathan JacobsBy: Jonathan Jacobs 146 NE 32nd Ave, Ocala, FL 34470 Phone: 386-503-0449 Email: MechaniCalcs@gmail.com Web: ineedHVACcalcs.com or MechaniCalcsLLC.com Project Information Seminole South LLCFor: 20 Seminole Rd, Atlantic Beach, FL 32233 Htg Clg Htg Clg Outside db 9538(°F)Inside db 7570(°F) Outside RH 43-(%)Inside RH 50-(%) Outside wb 77-(°F)Inside wb 63-(°F) Daily range 16-(°F)Design TD 2033(°F) Moisture diff. 44-(gr/lb) Cooling EquipmentHeating Equipment Make Mitsubishi Electric Make Mitsubishi Electric Model MUZ-HM15NA*** Model MUZ-HM15NA*** Type Split ASHP Type Split ASHP Efficiency 10 HSPF COP / EER / SEER 18.0 Heating Input Sensible Cooling MBtuh11.2 Heating Output MBtuh @ 47°F18.0 Latent Cooling MBtuh2.8 Humidifier gpd2.4 Total Cooling MBtuh14.0 Leaving Air Temp °F70.0 Leaving Air Temp °F55.0 Actual Heating Fan cfm0 Actual Cooling Fan cfm467 Equipment Location System 2 System Type PEAKCV Fan Motor Heat Type PACKAGE Fan & Motor Combined Efficiency %0 Static Pressure Across Fan in H2O0 NAME Area Heat Sensible Latent Htg Clg Time ft²Loss Gain Gain cfm cfm Storage 361 Jul 1500 LDT4670237790276463 Restroom 55 Jul 1500 LDT00000 System 2 416 6463 9027 2377 0 467 Jul 1500 LDT 2022-Feb-17 09:01:29 Right-Suite® Universal 2021 21.0.11 RSU00000 Page 1 ...SC Builders\Seminole South - 20 Seminole Rd.rup Calc = MN5 Front Door faces: SE Job:Right-Suite® Universal 2021 Load Summary Feb 16, 2022Date:System 1 Jonathan JacobsBy: Jonathan Jacobs 146 NE 32nd Ave, Ocala, FL 34470 Phone: 386-503-0449 Email: MechaniCalcs@gmail.com Web: ineedHVACcalcs.com or MechaniCalcsLLC.com Project Information Seminole South LLCFor: 20 Seminole Rd, Atlantic Beach, FL 32233 COOLING LOADSystem 1Zone: Peak load at Jul 1500 LDTat Jul 1500 LDT1. DESIGN CONDITIONS Inside: °F75 Outside: °F95 TD: °F20 RH: 43 % MoistDiff: gr/lb44.1 Mult: 1.0 Ins.wb °F63 Sensible Latent 66062. SOLAR RADIATION THROUGH GLASS - 3. TRANSMISSION GAINS Sensible 9147 - Walls: 180 - - Glass: 3043 - - Doors: 0 - - Partitions: 0 - - Floors: 0 - - Ceilings: 5924 - - 4. INTERNAL HEAT GAIN Sensible Latent 200014106 Occupants:20001900 - - Lights: 8487 - - - Motors: 0 - - - Appliances:03719 - - 5. INFILTRATION:0Outside air cfm: 0 0 6. SUBTOTAL:Space load Sensible Latent 200029858 Envelope 200029858 - - Less external 0 - - - Redistribution 00 - - 07. SUPPLY DUCT - 8. SUBTOTAL:Space load + supply duct 29858 - 1750Actual cfm: at supply TD: 20 - - Make-up air cfm:9. VENTILATION:6212278 8328 10. RETURN AIR LOAD:Lighting + plenum (net) 0 - 011. RETURN DUCT - 103283607112. TOTAL LOADS ON EQUIPMENT HEATING LOAD 13. DESIGN CONDITIONS Mult: 1.0 Inside: °F70 Outside: °F38 TD: °F33 14. TRANSMISSION LOSSES 10875 Walls: 169 - Glass: 5370 - Doors: 0 - Partitions: 0 - Floors: 804 - Ceilings: 4532 - 15. INFILTRATION:00Outside air cfm: 16. SUBTOTAL:Space load 10875 Envelope 10875 - Less external 0 - Less transfer 0 - Redistribution 0 - 17. SUPPLY DUCT:0 18. VENTILATION:9931278Make-up air cfm: 19. HUMIDIFICATION 2015 Piping 0 20. RETURN DUCT 0 21. TOTAL HEATING LOAD ON EQUIPMENT 22822 2022-Feb-17 09:01:29 Right-Suite® Universal 2021 21.0.11 RSU00000 Page 2 ...SC Builders\Seminole South - 20 Seminole Rd.rup Calc = MN5 Front Door faces: SE Job:Right-Suite® Universal 2021 Load Summary Feb 16, 2022Date:System 2 Jonathan JacobsBy: Jonathan Jacobs 146 NE 32nd Ave, Ocala, FL 34470 Phone: 386-503-0449 Email: MechaniCalcs@gmail.com Web: ineedHVACcalcs.com or MechaniCalcsLLC.com Project Information Seminole South LLCFor: 20 Seminole Rd, Atlantic Beach, FL 32233 COOLING LOADSystem 2Zone: Peak load at Jul 1700 LDTat Jul 1500 LDT1. DESIGN CONDITIONS Inside: °F75 Outside: °F95 TD: °F20 RH: 43 % MoistDiff: gr/lb44.1 Mult: 1.0 Ins.wb °F63 Sensible Latent 02. SOLAR RADIATION THROUGH GLASS - 3. TRANSMISSION GAINS Sensible 2655 - Walls: 346 - - Glass: 0 - - Doors: 124 - - Partitions: 0 - - Floors: 0 - - Ceilings: 2186 - - 4. INTERNAL HEAT GAIN Sensible Latent 12505531 Occupants:12501188 - - Lights: 3112 - - - Motors: 0 - - - Appliances:01232 - - 5. INFILTRATION:38Outside air cfm: 841 1127 6. SUBTOTAL:Space load Sensible Latent 23779027 Envelope 23779027 - - Less external 0 - - - Redistribution 00 - - 07. SUPPLY DUCT - 8. SUBTOTAL:Space load + supply duct 9027 - 467Actual cfm: at supply TD: 20 - - Make-up air cfm:9. VENTILATION:00 0 10. RETURN AIR LOAD:Lighting + plenum (net) 0 - 011. RETURN DUCT - 2377902712. TOTAL LOADS ON EQUIPMENT HEATING LOAD 13. DESIGN CONDITIONS Mult: 1.0 Inside: °F70 Outside: °F38 TD: °F33 14. TRANSMISSION LOSSES 3279 Walls: 657 - Glass: 0 - Doors: 120 - Partitions: 0 - Floors: 836 - Ceilings: 1666 - 15. INFILTRATION:229264Outside air cfm: 16. SUBTOTAL:Space load 5571 Envelope 5571 - Less external 0 - Less transfer 0 - Redistribution 0 - 17. SUPPLY DUCT:0 18. VENTILATION:00Make-up air cfm: 19. HUMIDIFICATION 892 Piping 0 20. RETURN DUCT 0 21. TOTAL HEATING LOAD ON EQUIPMENT 6463 2022-Feb-17 09:01:29 Right-Suite® Universal 2021 21.0.11 RSU00000 Page 1 ...SC Builders\Seminole South - 20 Seminole Rd.rup Calc = MN5 Front Door faces: SE Job:Duct System Summary Feb 16, 2022Date:System 1 Jonathan JacobsBy: Jonathan Jacobs 146 NE 32nd Ave, Ocala, FL 34470 Phone: 386-503-0449 Email: MechaniCalcs@gmail.com Web: ineedHVACcalcs.com or MechaniCalcsLLC.com Project Information Seminole South LLCFor: 20 Seminole Rd, Atlantic Beach, FL 32233 CoolingHeating External static pressure in H2O0.60in H2O0.60 Pressure losses in H2O0.37in H2O0.32 Available static pressure in H2O0.23in H2O0.28 Supply / return available pressure 0.156 / 0.124 in H2O in H2O0.128 / 0.102 Lowest friction rate in/100ft0.121in/100ft0.148 Actual air flow cfm1750cfm0 Total effective length (TEL)ft189 Supply Branch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Eqv Name (Btuh)(cfm) (cfm)FR (in)(in)Matl Ln (ft)Ln (ft) Trunk st1A43.314.5ShMt0x09.00.22135005972cShowroom-A st131.97.5ShMt0x09.00.32435005972cShowroom-B st1C62.928.5ShMt0x09.00.14035005972cShowroom-C st1B54.021.5ShMt0x09.00.16935005972cShowroom-D st1D69.735.5ShMt0x09.00.12135005972cShowroom-G Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm)(cfm)FR (fpm)(in)(in)Material Trunk st1D Peak AVF 0 350 0.121 446 12.0 0x0 ShtMetl st1C st1B Peak AVF 0 1050 0.121 752 16.0 0x0 ShtMetl st1A st1A Peak AVF 0 1400 0.121 792 18.0 0x0 ShtMetl st1 st1 Peak AVF 0 1750 0.121 802 20.0 0x0 ShtMetl st1C Peak AVF 0 700 0.121 655 14.0 0x0 ShtMetl st1B Return Branch Detail Table Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size (in) (cfm)(cfm)(ft)FR (fpm)(in)(in)Opening (in) Matl Trunk rb3 0x 00 263 84.1 0.121 594 9.0 x0 0 ShMt rb2 0x 00 1488 0 0 0 0 x0 0 VlFx 2022-Feb-17 09:01:29 Right-Suite® Universal 2021 21.0.11 RSU00000 Page 2 ...SC Builders\Seminole South - 20 Seminole Rd.rup Calc = MN5 Front Door faces: SE Job:Duct System Summary Feb 16, 2022Date:System 2 Jonathan JacobsBy: Jonathan Jacobs 146 NE 32nd Ave, Ocala, FL 34470 Phone: 386-503-0449 Email: MechaniCalcs@gmail.com Web: ineedHVACcalcs.com or MechaniCalcsLLC.com Project Information Seminole South LLCFor: 20 Seminole Rd, Atlantic Beach, FL 32233 CoolingHeating External static pressure in H2O0.50in H2O0.50 Pressure losses in H2O0in H2O0 Available static pressure in H2O0.50in H2O0.50 Supply / return available pressure 0.250 / 0.250 in H2O in H2O0.250 / 0.250 Lowest friction rate in/100ft0in/100ft0 Actual air flow cfm467cfm0 Total effective length (TEL)ft0 Supply Branch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Eqv Name (Btuh)(cfm) (cfm)FR (in)(in)Matl Ln (ft)Ln (ft) Trunk 00VlFx0x00046709209cStorage Return Branch Detail Table Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size (in) (cfm)(cfm)(ft)FR (fpm)(in)(in)Opening (in) Matl Trunk rb1 0x 00 467 0 0 0 0 x0 0 VlFx 2022-Feb-17 09:01:29 Right-Suite® Universal 2021 21.0.11 RSU00000 Page 1 ...SC Builders\Seminole South - 20 Seminole Rd.rup Calc = MN5 Front Door faces: SE Job:Static Pressure and Friction Rate Feb 16, 2022Date:System 1 Jonathan JacobsBy: Jonathan Jacobs 146 NE 32nd Ave, Ocala, FL 34470 Phone: 386-503-0449 Email: MechaniCalcs@gmail.com Web: ineedHVACcalcs.com or MechaniCalcsLLC.com Project Information Seminole South LLCFor: 20 Seminole Rd, Atlantic Beach, FL 32233 Available Static Pressure CoolingHeating (in H2O)(in H2O) 0.600.60External static pressure Pressure losses 0.050Coil 0.020.02Heat exchanger 0.050.05Supply diffusers 0.050.05Return grilles 0.200.20Filter 00Humidifier 00Balancing damper 00Other device 0.230.28Available static pressure Total Effective Length ReturnSupply (ft)(ft) 271Measured length of run-out 035Measured length of trunk 5870Equivalent length of fittings 84105Total length 189Total effective length Friction Rate CoolingHeating (in/100ft)(in/100ft) OK0.121OK0.148Supply Ducts OK0.121OK0.148Return Ducts Fitting Equivalent Length Details 4AI=20, 2P0=50, 12J1=10, 12J1=10, 12J1=10, 12J1=10, 1A=35, VelAdj=-75: TotalEL=70Supply 6L=20, 8A7=30, 8A7=30, 5B=40, VelAdj=-62: TotalEL=58Return 2022-Feb-17 09:01:29 Right-Suite® Universal 2021 21.0.11 RSU00000 Page 2 ...SC Builders\Seminole South - 20 Seminole Rd.rup Calc = MN5 Front Door faces: SE Job:Static Pressure and Friction Rate Feb 16, 2022Date:System 2 Jonathan JacobsBy: Jonathan Jacobs 146 NE 32nd Ave, Ocala, FL 34470 Phone: 386-503-0449 Email: MechaniCalcs@gmail.com Web: ineedHVACcalcs.com or MechaniCalcsLLC.com Project Information Seminole South LLCFor: 20 Seminole Rd, Atlantic Beach, FL 32233 Available Static Pressure CoolingHeating (in H2O)(in H2O) 0.500.50External static pressure Pressure losses 00Coil 00Heat exchanger 00Supply diffusers 00Return grilles 00Filter 00Humidifier 00Balancing damper 00Other device 0.500.50Available static pressure Total Effective Length ReturnSupply (ft)(ft) 00Measured length of run-out 00Measured length of trunk 00Equivalent length of fittings 00Total length 0Total effective length Friction Rate CoolingHeating (in/100ft)(in/100ft) < 0.060< 0.060Supply Ducts < 0.060< 0.060Return Ducts Fitting Equivalent Length Details TotalEL=0Supply TotalEL=0Return Job #: Performed by Jonathan Jacobs for: Seminole South LLC 20 Seminole Rd Atlantic Beach, FL 32233 Jonathan Jacobs 146 NE 32nd Ave Ocala, FL 34470 Phone: 386-503-0449 ineedHVACcalcs.com or MechaniCalcsLLC.com MechaniCalc... Scale: 1 : 104 Page 1 Right-Suite® Universal 2021 21.0.11 RSU00000 2022-Feb-17 09:01:36 ...inole South - 20 Seminole Rd.rup N First Storage Restroom AH Showroom Adjacent RightAdjacent Left 12 x 12 467 cfm12 x 12 467 cfm Split ASHP Mitsubishi Electric MUZ-HM15NA*** MSZ-HM15NA*** System 2 Split ASHP Carrier 25HCE460AP0300 FB4CNP061L System 1 12 x 12 263 cfm Ret Riser Ø9 " Ø9 " 24 x 48 1488 cfm 277 CFM Fresh Air Per FBC Mech Table 403.3 50 CFM Bath Exhuast To Outside 14 x 10 350 cfm Ø9 " 14 x 10 350 cfm Ø9 " 14 x 10 350 cfm Ø9 " 14 x 10 350 cfm Ø16 " Ø9 " 14 x 10 350 cfm Ø9 " Ø20 " Ø18 " Ø14 " Ø12 " MOTION SENSOR SWITCHMOTION SENSOR SWITCHA/C36 A/CA/CWHFEBFEBRoy c WilliamsDigitally signed by Roy c Williams Date: 2022.04.26 12:46:35 -04'00'By Toni Gindlesperger at 3:20 pm, May 02, 2022By Dan Arlington at 5:40 pm, Jun 08, 2022REVIEWED FOR CODE COMPLIANCE