Loading...
705 Atlantic Blvd, Unit 32 - COMM22-0018 Plumbing PlansN CLEANOUTS DETAILSA DATE:ISSUE:PERMITDRAWING:ALL REPORTS, SPECIFICATIONS, COMPUTER FILES, FIELD DATA AND OTHER DOCUMENTATION PREPARED BY THE OFFICE OF ARCHITECTURE AND DESIGN, INC. (OAD) AS INSTRUMENTS OF SERVICE SHALL REMAIN THE PROPERTY OF OAD. OAD SHALL RETAIN ALL COMMON LAW, STATUATORYAND OTHER RESERVED RIGHTS, INCLUDING THE COPYRIGHT THERETO. THIS DRAWING SHALL NEVER BE REPRODUCED IN WHOLE OR IN PART WITHOUT THE EXPRESS WRITTEN PERMISSION OF OADJulius E. Harden, PE 68,229 2021.12.20P001PLUMBING ABBREVIATIONS, LEGEND,AND NOTES2 WASTE/VENT RISER DIAGRAM NTS 1 WASTE/VENT RISER DIAGRAM NTS Julius E Harden Digitally signed by Julius E Harden DN: c=US, o=Florida, dnQualifier=A01410D0000017 FD0F4FADB000725BF, cn=Julius E Harden Date: 2022.04.06 22:46:19 -04'00' Adobe Acrobat Reader version: 2022.001.20085 By Toni Gindlesperger at 4:38 pm, Apr 15, 2022 GENERAL PLUMBING NOTES PLUMBING LEGEND 1. IN THE PREPARATION OF THESE PLANS, THE ENGINEER HAS USED CERTAIN ABBREVIATIONS, CONVENTIONS, AND SYMBOLS, THE MEANING OF WHICH ARE ILLUSTRATED AND EXPLAINED WITHIN THE LEGEND. 2. PLANS ARE DIAGRAMMATIC ONLY. THEY ARE INTENDED TO INDICATE CAPACITY, SIZE, LOCATION, DIRECTION AND GENERAL ARRANGEMENT, BUT NOT EXACT DETAILS OF CONSTRUCTION. THE FACT THAT ONLY CERTAIN FEATURES OF THE INSTALLATION ARE INDICATED MUST NOT BE TAKEN TO MEAN THAT OTHER FEATURES WILL NOT BE REQ'D. 3. COORDINATE WITH THE OTHER TRADES TO INSURE THAT EACH TRADE SHALL HAVE SUFFICIENT SPACE TO INSTALL THEIR EQUIPMENT (DUCTWORK, PIPING, ELECTRICAL WORK, ETC.). 4. ALL WORK & MATERIAL SHALL BE PERFORMED & INSTALLED IN COMPLIANCE WITH ALL CODES AS ADOPTED & AMENDED BY THE INSPECTING AUTHORITY. NOTHING IN THESE DRAWINGS IS TO BE CONSTRUED TO PERMIT WORK NOT CONFORMING TO THESE CODES. 5. VERIFY ALL DIMENSIONS FROM ARCHITECTURAL PLANS AND FIELD DIMENSIONS. 6. ALL RISES AND DROPS IN PIPING ARE NOT NECESSARILY SHOWN. 7. PROVIDE STOP OR ANGLE VALVES ON EACH WATER CONNECTION TO EACH PLUMBING FIXTURE. 8. PROVIDE ALL STRUCTURAL MEMBERS, SUPPORT BRACKETS, FLASHING, HARDWARE, ETC. REQUIRED TO INSTALL A COMPLETE SYSTEM. 9. PROVIDE CHROME PLATED ESCUTCHEON PLATES AT ALL EXPOSED WALL PENETRATIONS AND CLG. PENETRATIONS. 10. PROVIDE CLEANOUTS ON SANITARY LINES AND CONDENSATE DRAIN LINES AS REQUIRED BY CODE. 11. PROVIDE SHUT-OFF VALVE AT ALL PIPING WITH 2 OR MORE FIXTRUES. PROVIDE ACCESS PANELS FOR ALL SHUT-OFF VALVES LOCATED ABOVE GYP. BOARD CEILINGS. COORDINATE WITH G.C .. 12. BEFORE COMMENCEMENT OF WORK, CONTRACTOR SHALL VERIFY THE EXACT LOCATIONS, ELEVATIONS & CHARACTERISTICS OF ALL EXISTING AND NEW UTILITIES & PIPING. AND SHALL NOTIFY THE ARCHITECT/ENGINEER OF ANY DISCREPANCIES. 13. APPROVAL GRANTED ON SHOP DRAWINGS IS RENDERED AS A SERVICE ONLY AND SHALL NOT BE CONSIDERED AS GUARANTEE OF MEASUREMENTS OF BUILDING CONDITIONS; NOR SHALL IT BE CONSTRUED AS RELIEVING THE MECHANICAL CONTRACTOR OF BASIC RESPONSIBILITIES UNDER THIS CONTRACT. PIPE MAJEBIAL UST· 1. SANITARY, WASTE, ANO VENT PIPING: FITTINGS SHALL BE LONG RADIUS FITTINGS, EXCEPT FITTINGS IN VENT PIPING MAY BE SHORT RADIUS FITTINGS. CONTRACTOR OPTIONS: A. BELOW GRADE: CAST IRON, ASTM A74, STANDARD, SINGLE HUB, COATED. B. ABOVE GRADE: CAST IRON, NO HUB, CISPI STANDARD 301. C. ABOVE AND BELOW GRADE: PVC. SCHEDULE 40, MEETING ASTM D1785. ----- ---- ---- - ----io -----+-:::, -- 0 -T&P- -ED- ----l><J-- !1-- ----lXXI- FIXTURE - - -- -- -··-··- - - s CPVC WATER PIPING AND PVC WASTE, VENT AND ROOF DRAIN PIPING RUN IN RElURN AIR PLENUMS: WRAP WITH A FIRE PROTECTIVE JACKET WITH A MAXIMUM FLAME SPREAD RA TING OR 25 AND A MAXIMUM SMOKE DEVELOPMENT RA TING OF 50 IN ACCORDANCE. 2. DOMESTIC WATER PIPING CONTRACTORS OPTIONS: A. BELOW GRADE: TYPE K, COATED WITH COAL TAR SHELLAC. B. ABOVE GRADE: TYPE L. C. ABOVE AND BELOW GRADE UP TO 1 1 /4": CPVC MEETING ASTM D2846. COLD WATER PIPE HOT WATER PIPE SOIL OR WASTE PIPE VENT PIPE TURNED UP TURNED DOWN TEE, OUTLET DOWN TEE, OUTLET UP TEMPERATURE AND PRESSURE RELIEF DRN. PIPING EMERGENCY DRN PAN PIPING GATE VALVE PRESSURE RELIEF VALVE BALL VALVE PLUMBING FIXTURE DESIGNATION (UNDERLINED) HOT WATER RETURN PIPE EXISTING COLD WATER EXISTING HOT WATER EXISTING HOT WATER RETURN CONNECT TO EXISTING D. ABOVE AND BELOW GRADE 1 1/2" AND LARGER: CPVC SCHEDULE 80 MEETING ASTM DF441 AND ASTM F439. E. EXTERIOR DOMESTIC WATER PIPING: PVC, SCHEDULE 4D MEETING ASTM D1785. DOMESTIC COLD & HOT WATER PIPING AND FITTINGS ARE TO BE INSULATED WITH 1 INCH FIBERGLASS STANDARD PIPE INSULATION l'f1TH ALL SERVICE JACKET. PLUMBING JESTING AND DISINFECTING· 1. TESTING: A. SOIL, WASTE, VENT SYSTEM: 1. TEMPORARILY PLUG AUL OUTLETS. 2. FILL LINES WITH WATER TO THE ROOF LEVEL. 3. ALLOW TO REMAIN FULL FOR 24 HOURS. B. WATER SYSTEM: 1. TEST AT 150 PERCENT OF DESIGN PRESSURE BUT NOT LESS THAN 100 PSIG. 2. ALLOW PRESSURE TO REMAIN ON LINE FOR 24 HOURS. C. REPAIR ALL DETECTABLE LEAKS IN PIPING SYSTEMS. 2. DISINFECTION OF DOMESTIC WATER SYSTEM: A. DISINFECT DOMESTIC WATER SYSTEM AFTER APPROVAL OF TEST RESULTS AND PIPING INSTALLATION BY BUILDING OFFICIAL 8. PRIOR TO SUBSTANTIAL COMPLETION STERILIZE PIPING SYSTEM IN ACCORDANCE WITH LOCAL PLUMBING CODE REQUIREMENTS. C. DELIVER CERTIFICATION TO BUILDING OFFICIAL ABBREVIATIONS AFF ABOVE FINISHED FLOOR BTU BRITISH THERMAL UNIT OESIGNATIQN MAN!,!FACI!JRER CONN CONNECTION cw COLD WATER ED EQUIPMENT DRAIN P-1 ZURN EX EXISTING FL FILOOR FU FIXTURE UNIT GC GENERAL CONTRACTOR P-2 JOSAM GPM GALLONS PER MINUTE OR EQUAL HW HOT WATER IN INCHES MIN MINIMUM PC PLUMBING CONTRACTOR SAN OR S SANITARY P-3 -- V VENT VTR VENT TO ROOF WTR WATER P-4 ZURN W/ V.,TH W/0 v.1THOUT w WASTE DN DOWN HW HOT WATER HWR HOT WATER RETURN co CLEANOUT wco WALL CLEANOUT GENERAL SYMBOLS 0 KEYED NOTE NUMBER & REVISION NUMBER NORTH ARROW PLUMBING FIXTURE SCHEDULE MQDEL NQ. Z-1901 60103-SA -- Z-415 W/ TYPE "B" STRAINER .P::1 EIXI!JRE OESCRIPTIQN CONNECTION SCHEDULE FLOOR SINK -12" x 12" x 8" DEEP SUMP, 4" OUTLET GREASE INTERCEPTOR WITH SEMI-AUTOMATIC GREASE REMOVAL DEVICE EQUAL 60103-SA; FLOW RA TE 10 GPM; GREASE CAPACITY 20 LBS PIPE SIZE 2" HUB INLET. SINGLE COMPARTMENT SINK PROVIDED BY OWNER/KITCHEN MANUFACTURER; PLUMBING CONTRACTOR TO PROVIDE PLUMBING FIXTURE CONNECTIONS. COLD & HOW WATER SHALL BE PROVIDED WITH SHUT OFF VAL VE. FLOOR DRAIN W/ 5" NICKALOY STRAINER TOP AND 3" OUTLET PROVIDE AUXILIARY INLET FITTING FOR TIRAP PRIMER CONNECTION -~ ..._ -..';y . I / I .... ~~ '-(1-1 WASJE 4" 3" -- 3" YEN.I ~ 2" -- --- --1/2" 2" -- TO EXISTING ( >[' '-. ------CONNECT 2"V I ~I ~ ~M~OC~ :::,. STIRUCTURAL. I ~I IDE OF Cl I :I hr-EXISTING HAND SINK I I H.Yl -- -- 1/2" -- o----- / CO W/ICCFSS COYER. TOP bF COVER FUJSH W/TOP OF FLOOR . .. -1/8 BEND BI\IANCE OF PIPING SAME AS CI.EANOUT TO GRADE a£ANOUT SHAUL NOT BE LOCATED IN CARPEIED NIEA ROOR Cl FMfQUT FINISHm r BRASS CO PLUG W/COUNIER GRADE l / SUNK HOO 16'' SQUARE CONCRETE PAD TROWEL SMOOTH AND EDGE CONCRETE 4" DEEP WITH WWF -------------REINFORCEMENTS WASTE LINE; l.ENG'IH TO SUIT WASTE LINE 1 /8 BEND IF CI.EANOUT OCCURS AT END OF LINE Cl FANOUT m GRAPE 0 --NTS EXISTING 3"SAN BELOW FLR. _____ _..,- 0----- INDEX TO PLUMBING DRAWINGS SHEET SHEET TITLE P001 PLUMBING ABBREV.. LEGEND, NOTES, AND SCHEDULE P101 PLUMBING FLOOR PLANS J. HARDEN & ASSOCIATES, LLC [ RECEIVED l ENGINEERING CONSULTANT CE RI FICA TE OF AUTHOR/ZA T/ON: 28871 PH: 904-677-2290 EMAIL: julius@ihaengineerlng.net ' z z N <D ... 0 ... a> -C: + a> ... ::, -0 a> -.c 0 ... "' '""" ✓ ---- l'1 l'1 N N I l'1 w o__J I->LL <( __J • __J CDI 0 (.) (.) (.) <( 0 1-W I zzCD (.) 0 <( -(.) :::) VlFI- Z Z<(Z w <( <( :,,: 0.. LO __I <( XOI-:::;; w r---<( DATE:ISSUE:PERMITDRAWING:ALL REPORTS, SPECIFICATIONS, COMPUTER FILES, FIELD DATA AND OTHER DOCUMENTATION PREPARED BY THE OFFICE OF ARCHITECTURE AND DESIGN, INC. (OAD) AS INSTRUMENTS OF SERVICE SHALL REMAIN THE PROPERTY OF OAD. OAD SHALL RETAIN ALL COMMON LAW, STATUATORYAND OTHER RESERVED RIGHTS, INCLUDING THE COPYRIGHT THERETO. THIS DRAWING SHALL NEVER BE REPRODUCED IN WHOLE OR IN PART WITHOUT THE EXPRESS WRITTEN PERMISSION OF OADJulius E. Harden, PE 68,229 2021.12.20P101PLUMBING FLOOR PLANS2 PLUMBING FLOOR PLAN SCALE: 1/4"=1'-0" 1 PLUMBING DEMOLITION FLOOR PLAN SCALE: 1/4"=1'-0" Julius E Harden Digitally signed by Julius E Harden DN: c=US, o=Florida, dnQualifier=A01410D0000017F D0F4FADB000725BF, cn=Julius E Harden Date: 2022.04.06 22:46:36 -04'00' Adobe Acrobat Reader version: 2022.001.20085 PLUMBING NOTES· 0 1. 1/2" CW DOWN TO CARBON TWO STAGE FILTRATION SYSTIEM EQUAL TO KOHLER MODEL 77686-NA CONNECTIED TO COFFEE STATION. 2. PROVIDE TEMPERED WATER FOR ALL HAND-WASHING SINKS USING A WATER TEMPERATURE LIMITING DEVICE AT THE POINT OF USE lHAT CONFORMS TO ASSE 1070 OR CSA Bl 25.R I / I L __ _ ~ O@ ~ 0-) ' '-._./ -3/4"CW ,-1-l -~ - ---= ----I - ---= I ~ I ) -~ " c;, = -I -~ I I I - - 1/C y '---\ I I I n=:- I I I I',' c;, c;, 0 ]0 - -e,;,; I I © I l __ d -~~-- - - I © -1 'i= " " S: 0 1. REMOVE EXISTING PLUMBING FIXllJRE; CAP SANITARY BELOW AT FLR WITH FLOOR CLEAN OUT; CAP CW & HW AT UNDERSIDE OF STRUCTURE. 2. REMOVE EXISTING HAND SINK; CAP SANITARY BELOW AT FLR WITH FLOOR CLEAN OUT; CAP CW & HW AT UNDERSIDE OF STRUCllJRE 3. REMOVE EXISTING (3) COMPARTMENT SINK & FLOOR SINK; SEE PLUMBING FLR PALN FOR NEW LOCATION. 4. REMOVE & RELOCATIE EXISTING SINGLE --0 --• •-• --••-•IT CIMV C"I nnn C'IMII', CC"C" n1 I 1un1._IC::: ~IC '---<i-6" PLAN FOR NEW LOCATION. f tJ , □1 EXISTING lHREE COMPARlMENT SINK fi-1+--ll+--_ I 1 • cw \ / I 3"SAN CAP / AT FLR. ~...,...,; , L- □1 0----- -n -_µJ --------"=-..r~-- --- .,, I _J 1/2"HW CAP ABOVE CLG. I / I L _____ _ i L_J / I I I I I ' \ I 11~ I I I ,-, ,-, I I I L _ _J L _ _J <------> Qi-------- 17 I I I I LJ I l_ _ _J I r7 L -.Ji r7 L -.Ji r7 L __J r7 L__j r7 L ...J ' \ I _____ J I ~ ' - '---=' -' ' -\ J I ' I J J. HARDEN & ASSOCIATES, LLC ENGINEERING CONSULTANT CE RI FICA TE OF AUTHOR/ZA T/ON: 28871 PH: 904-677-2290 EMAIL: julius@ihaengineerlng.net z z N <D ... 0 ... a> -C: + a> ... ::, -0 a> -.c 0 ... "' '""" ✓ ---- l'1 l'1 N N I l'1 w o_J I->LL <( _J • _J CDI 0 (.) (.) (.) <( 0 1-W I zzCD (.) 0 <( -(.) :::) VlFI- Z Z<(Z w <( <( :,,: 0.. LO _j <( XOI-:::;; w r---<(