Loading...
Ordinance No. 25-65-5 v 0110 ORDINANCE NO, 25-65- 5 AN ORDINANCE AMENDING ORDINANCE NO. 25-59-1 OF THE CITY OF ATLANTIC BEACH: WHICH PROVIDES FOR FIRE LIMITS , AND RJGULATIONS GOVERNING THE CONSTRUCTION, ALTERATION, REMOVAL, DEMOLITION EQUIPMENT, USE AND OCCUPANCY, LOCATION AND MAINTENANCE OF BUILDINGS AND STRUCTURES. BE IT ENACTED BY THE PEOPLE OF THE CITY OF ATLANTIC BEACH, FLORIDA, that, SECTION I. Section 1, Adoption of Building Code, as specified in Ordinance 25-59-1 be and is hereby amended in that with reference to the Southern Standard Building Code the designa- tion "1957-1958 revision" be deleted, and the designation "1965 Edition" be inserted in lieu thereof. SECTION II . Section 6 . Amendments made in said Code be and is hereby amended as follows. A. Paragraphs (1) through (4) , paragraphs (6) through (9) , and paragraph (11) remain unchanged. B. Paragraph (5) is hereby amended in that the first fire district shall include all that territory embraced within Business AA and Business Al Districts, in addition to territory embraced within Business A District. C. Paragraph (10) is hereby amended by addition of: Compliance with Section 1408. 2 of the Code is inten- ded; and in addition thereto, the wood plate or beam (bolted to the masonry lintel or spandrel beam) shall be fastened with hurricane clips to each joist, rafter or roof truss at every point of bearing. D. Paragraph (12) is hereby amended in that reference to Section 1701.7 of said Code is hereby deleted and stricken; and in lieu thereof the following addi- tional sub-sections are substituted: Section 1701. 3 (a) FOUNDATION WALL VENTS Space under first floor joists, except in such . space as is occupied by a basement or cellar, shall be provided with openings to insure ventilation. Such ventilating openings shall be proportioned on the basis of not less than one and one-half (11/2) Sq. Ft. net opening for each r . - L. . j ,s1 ds 4111 cl- Ordinance No. 25-65- 5 Page #2 1 \', fifteen (15) lineal feet or major fraction thereof of exterior wall. Vents shall be so jhplaced as to provide ventilation at all points jC and prevent dead air pockets; they need not be il placed in the front of the building. Such openings shall be screened with 4:q1 sallmileleld****snibucaursit galvanized hardware cloth Ak- ,t ate.,. `ti cam- ..).„2„.1., 7.,..0a✓'t-Zc e�- (b) CLEARANCE There shall be clearance of not less than eighteen (18) inches between the bottom of untreated wood framing and the ground beneath (c) FOUNDATION SILLS All masonry shall be finished to provide a true and even bearing surface for wooden structural members. Such structural members All shall be securely fastened to the masonry or concrete bearing surface. All foundation sills shall be bolted with not less than one-half (1/2) inch diameter bolts securely embedded in the masonry spaced not more than six (6) feet apart. All wood foundation sills which are less than 18 inches above exposed unprotected ground under the building, shall be a heartwood grade of a durable species, or shall be pressure treated with an approved preservative. All foundation sills shall be separated from contact with foundations of unit masonry by not less than 28 ga. Galvanized iron or other approved corrosion- resistant metal, or by slate or may be bedded in 1:3 cement mortar. All sleepers imbedded in or on concrete on ground shall be pressure treated lumber or heart grade Redwood, Cedar or Tidewater Cypress. E. Paragraph 13 is hereby amended in that reference to Section 1704.8 of said Code is hereby deleted and stricken; and in lieu thereof Section 1707 . 1 is hereby amended by addition of the following sub- 411/1 paragraph: (i) Each and every rafter, trussed rafter or roof joist shall be fastened with a hurricane clip at every point of contact to its support- ing wall plate or ceiling joist. l f Ordinance No. 25-65- 5 Page #3 41/1 F. Add to Section 6 a paragraph (14) as follows: Section 2706. 1 GLASS AND PLASTIC REQUIREMENTS (a) Windows in either wood or metal sash, having sill 30 or more inches above floor shall be glazed within the following minimum requirements: Area not over 9 sq. ft. Double strength, common or sheet glass Area over 9 sq. ft. but less than 18 sq. ft. , 3/16 " plate glass Area over 18 sq. ft. but not over 27 sq. ft. , 1/4" plate glass Area over 27 sq. ft. but not over 82 sq. ft. , 1/2" plate glass (b) Windows of which sill is at or near floor level, Glass doors and adjacent glass panels, which with sliding glass door constitute a glass door assembly, shall be of one of the following types: 1. Approved laminated safety glass - as used in Auto windshields. 2. Approved full tempered glass not less than 1/4" in thickness. And where glass 1/4" thick of this type is used a horizontal metal mullion about waist height, must be permanently attached thereto and made part thereof. 3. Approved 1/4" thick, or heavier, wired glass in which wire diameter is not less than 0.02 inch and area enclosed by wire strands is not over 115 square inches. (c) Shower Enclosures if of glass shall be of the quality and characteristics specified in para- graph (b) above. (d) Shower and shower bath doors, other than sliding doors shall open outward. (e) Plastic used in fabrication of shower and shower bath enclosures, or assemblies, shall be of one of the following types: • 1. Fiberglass reinforced panels of a weight not less than 8 pounds per square foot. 4110 Ordinance No. 25-65- 5 Page #4 2. Acrylic Resin thermoplastic not less than 1/8" in thickness. 3. High impact Styrene not less than 1/8" in thickness. 4. Any plastic material not specifically men- tioned herein which may have been, or may be at a future date, specifically approved for such use by the Southern Building Code Congress; such approval having been duly published in a regular Compliance Report of Said Congress. SECTION III. Sections 7 , 8 and 9 of Ordinance 25-59-1 remain unchanged. SECTION IV. Ordinances or parts thereof in force at the time this ordinance shall take effect, and inconsistent herewith, are hereby repealed. SECTION V. This ordinance shall take effect immediately upon its passage. * * * * * * Passed by the City Commission on first reading July 12, 1965. Passed by the City Commission on second and final reading on July 26, 1965. Attest: ryelC _-)2 S -- • Adele S. Grage, City Cler (SEAL) Ttazzi. ter, certify that the above ordinance # 5.-' u:rasted�c ., � 7(f[. at the City Hall following its final' Claw J �C-4c� /•f� S- (Loi ems, • - Adele S. Grage, City C_ �rg