1937 BEACH AVE ROOF22-0031 COAB Permit Form with ConditionsOWNER:ADDRESS:CITY:STATE:ZIP:
ZISSER ELLIOT 1937 BEACH AVE ATLANTIC BEACH FL 32233-5936
COMPANY:ADDRESS:CITY:STATE:ZIP:
FORD ROOFING SYSTEMS
INC 3839 Millpoint Drive Jacksonville FL 32257
TYPE OF
CONSTRUCTION:
REAL ESTATE
NUMBER:ZONING:BUILDING USE
GROUP:SUBDIVISION:
169692 0100 NORTH ATLANTIC BCH
UNIT 2
JOB ADDRESS:PERMIT TYPE:DESCRIPTION: VALUE OF WORK:
1937 BEACH AVE ROOF NON SHINGLE ROOF OVER - METAL ROOF $45000.00
FEES
DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT
BUILDING PERMIT 455-0000-322-1000 0 $280.00
BUILDING PLAN CHECK 455-0000-322-1001 0 $140.00
STATE DBPR SURCHARGE 455-0000-208-0700 0 $6.30
STATE DCA SURCHARGE 455-0000-208-0600 0 $4.20
TOTAL: $430.50
LIST OF CONDITIONS
Roll off container company must be on City approved list . Container cannot be placed on City right-of-way.
NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property
that may be found in the public records of this county, and there may be additional permits required from other
governmental entities such as water management districts, state agencies, or federal agencies.
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN
YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT
MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU
INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE
RECORDING YOUR NOTICE OF COMMENCEMENT.
MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION.
ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING
CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES .
ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY.
1 of 2Issued Date: 6/21/2022
PERMIT NUMBER
ROOF22-0031
ISSUED: 6/21/2022
EXPIRES: 12/18/2022
ROOF NON SHINGLE PERMIT
CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
ATLANTIC BEACH, FL 32233
2 of 2Issued Date: 6/21/2022
PERMIT NUMBER
ROOF22-0031
ISSUED: 6/21/2022
EXPIRES: 12/18/2022
ROOF NON SHINGLE PERMIT
CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
ATLANTIC BEACH, FL 32233
41',%=,,, Building Permit Application Mr{nred 10/9/1$
d'.
s City of Atlantic Beach Building Department ALL INFORMATION
800 Seminole Road, Atlantic Beach, FL 32233 HIGHLIGHTED IN GRAY
J';'r
IS REQUIRED.Phone: (904) 247-5826 Email: Building-Dept@coab.us
Job Address: 1937 Beach Ave. Permit Number:R 2 Z` ( C5 , \
Legal Description 15-57 09-2S-29E N ATLANTIC BEACH UNIT NO 2 PT LOT 54 RE# 169692-0100
Valuation of Work(Replacement Cost)S 45000 Heated/Cooled SF Non-Heated/Cooled
Class of Work: iZiNew DAddition DAlteration [Repair DMove [Demo [Pool DWindow/Door
Use of existing/proposed structure(s): Commercial EdResidential
If an existing structure,is a fire sprinkler system installed?: DYes ONo
t1re'rs4 4,rIrmvrrd°m wisuerilercm'Wen Tot/rimed snritvell u`fe's'most•svh,rrih yra2trate-Wm Skernthrdi 4"er rriA', 1E-2114D
IDescribe in detail the type of work to be performed: I
Metal roof Re roof I
Florida Product Approval#33813.1 for multiple products use product approval form
Property Owner Information
Name Elliot Zinser Address 1937 Beach Ave.
City Maniac Beach State FL Zip 127V4 Phone 9047358518
E-Mail mfyomes149@yahoo.com
Owner or Agent(If Agent,Power of Attorney or Agency Letter Required)
rnntr,r*nr Information
Name of Company Ford Roofing Systems Inc. Qualifying Agent Robert Maust
Address 3839 Millpoint Dr City Jacksonville State FL Zip 32257
office phone 9043147671 Job Site Contact Number 9043147671
State Certification/Registration# CCC1327698 E-Mail fordroofing@gmail.c om
Architect Name&Phone#
Fngineer's Name R Phone U
Workers Compensation Insurer American zurich insurance OR Exempt Li Expiration Date 12/31/22
Application is hereby made to obtain a permit to do the work and installations as indicated.I certify that no work or installation has
commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all the laws regulating
construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK,PLUMBING,SIGNS,
WELLS, POOLS,FURNACES,BOILERS, HEATERS,TANKS,and AIR CONDITIONERS,etc. NOTICE: In addition to the requirements of this
permit,there may be additional restrictions applicable to this property that may be found in the public records of this county,and
there may be additional permits required from other governmental entities such as water management districts,state agencies,or
federal a&esKies.
OWNER'S AFFIDAVIT:I certify that all the foregoing information is accurate and that all work will be done in compliance with all
applicable laws regulating construction and zoning.
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY
RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR P' • 'ERTY. IF YOU INTEND
TO OBTAIN Fl ANCING, CONSULT WITH YOUR LENDER OR , . ,TTOR EY BEFORE
Ktw # fitl. . F C TMENCEMEN .
Signa a of• - . ,:ent) ApPV:105.11,117. ot
S' eed and sworn to(or - _rrmed)bgfore me thisA3 day of ; sworn to(or affirm jd)before a this 1 da of
0-gby ,Gt zr5 " r O12 ,by l c l lLi c
roe'...•.'
Commission If GO 851911
20;...s, GREGORY J.BARTHOLOMEW
Expires February 8,2024 5::
7617)
7,
71.1)14e,cr, * Commission#GG 951321
Personally Known OR Bi o 1 er anally Known OR 9 o Expires February6,2024
PRiduced Identification DOFF\gyp
Produced Identification rFoFFLo BondedThruBudgetNotaryServices
Type of Identification: /—L ID 4t-1.7 el-5°MS Type of Identification:
By Mike Jones at 11:28 am, Jun 07, 2022
REVIEWED FOR CODE COMPLIANCE
Revision Request/Correction to Comments **ALL INFORMATION
HIGHLIGHTED IN
GRAY IS REQUIRED. City of Atlantic Beach Building Department
800 Seminole Rd, Atlantic Beach, FL 32233
Phone: (904) 247-5826 Email: Building-Dept@coab.us PERMIT #: _____________________
Revision to Issued Permit OR Corrections to Comments Date: ________________
Project Address: ____________________________________________________________________________________
Contractor/Contact Name: ____________________________________________________________________________
Contact Phone: ______________________________ Email: _________________________________________________
Description of Proposed Revision / Corrections:
__________________________________________________________________________________________________
__________________________________________________________________________________________________
__________________________________________________________________________________________________
__________________________________________________________________________________________________
I_______________________________ affirm the revision/correction to comments is inclusive of the proposed changes.
(printed name)
Will proposed revision/corrections add additional square footage to original submittal?
No Yes (additional s.f. to be added: _____________________________)
Will proposed revision/corrections add additional increase in building value to original submittal?
No *Yes (additional increase in building value: $____________________) (Contractor must sign if increase in valuation)
*Signature of Contractor/Agent: _______________________________________________________
__________________________________________________________________________________________________
(Office Use Only)
Approved Denied Not Applicable to Department Permit Fee Due $_______________
Revision/Plan Review Comments_______________________________________________________________________
__________________________________________________________________________________________________
Department Review Required:
Building _____________________________________________
Planning & Zoning Reviewed By
Tree Administrator
Public Works
Public Utilities _____________________________________________
Public Safety Date
Fire Services Updated 10/17/18
ROOF22-0031
06/08/2022
1937 Beach Ave
fordroofing@gmail.com
Changes have been made to product approval sheet as needed. Also as requested it is a gable roof that has a pitch of
12/12.
Robert Maust
4
4
4
9043147671
By Toni Gindlesperger at 2:30 pm, Jun 09, 2022
By Mike Jones at 7:43 am, Jun 17, 2022
50.00X
a CREEK
Technical Services, LLC
GCS20002.2a FL33818-R2 Page 1 of 6 Page 1 of 23
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein.
Registry No. 29824
17520 Edinburgh Dr
Tampa, FL 33647
(813) 480-3421
EVALUATION REPORT FLORIDA BUILDING CODE, 7TH EDITION (2020)
Manufacturer: GULF COAST SUPPLY & MANUFACTURING, LLC Issued October 21, 2021
14429 SW 2nd Place, Suite G30
Newberry, FL 32669
(352) 498-7852
www.gulfcoastsupply.com
Manufacturing Locations: Alachua, FL
Sebring, FL
Montgomery, AL
Quality Assurance: PRI Construction Materials Technologies, LLC (QUA9110)
SCOPE
Category: Roofing
Subcategory: Metal Roofing
Code Sections: 1504.3
Properties: Wind Resistance
REFERENCES
Entity Report No. Standard Year Force Engineering & Testing (TST5328) 72-0313T-06A-C UL 580 UL 1897 2006 2012 Force Engineering & Testing (TST5328) 72-0198T-07A-C UL 580 UL 1897 2006 2012 Force Engineering & Testing (TST5328) 117-0033T-05 UL 580 UL 1897 2006 2012 Force Engineering & Testing (TST5328) 117-0053T-05 UL 580 UL 1897 2006 2012 Force Engineering & Testing (TST5328) 117-0062T-07A-C UL 580 UL 1897 2006 2012 Force Engineering & Testing (TST5328) 117-0062T-07D-F UL 580 UL 1897 2006 2012 Force Engineering & Testing (TST5328) 117-0062T-07G-I UL 580 UL 1897 2006 2012 Force Engineering & Testing (TST5328) 117-0062T-07J-K UL 580 UL 1897 2006 2012 Force Engineering & Testing (TST5328) 117-0065T-07A-C UL 580 UL 1897 2006 2012 Force Engineering & Testing (TST5328) 117-0076T-12A UL 580 UL 1897 2006 2012 Force Engineering & Testing (TST5328) 117-0089T-05.1 UL 580 UL 1897 2006 2012 Force Engineering & Testing (TST5328) 117-0089T-05.2 UL 580 UL 1897 2006 2012 Force Engineering & Testing (TST5328) 117-0102T-05 UL 580 UL 1897 2006 2012 Force Engineering & Testing (TST5328) 117-0165T-11B UL 580 UL 1897 2006 2012 Force Engineering & Testing (TST5328) 117-0238T-09D FM 4471 1992 Force Engineering & Testing (TST5328) 117-0238T-09E FM 4471 1992 Force Engineering & Testing (TST5328) 117-0238T-11A FM 4471 1992 Force Engineering & Testing (TST5328) 117-0248T-07A,B UL 580 UL 1897 2006 2012 Force Engineering & Testing (TST5328) 117-0284T-09A UL 580 UL 1897 2006 2012
By Toni Gindlesperger at 2:30 pm, Jun 09, 2022
By Mike Jones at 7:45 am, Jun 17, 2022
A CREEK
Technical Services, LLC
GCS20002.2a FL33818-R2 Page 2 of 6 Page 2 of 23
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein.
GULF COAST SUPPLY & MANUFACTURING, LLC Metal Roofing
Entity Report No. Standard Year Force Engineering & Testing (TST5328) 117-0285T-09A UL 580 UL 1897 2006 2012 Force Engineering & Testing (TST5328) 117-0301T-10A-C UL 580 UL 1897 2006 2012 Force Engineering & Testing (TST5328) 117-0330T-10A-B UL 580 UL 1897 2006 2012 Force Engineering & Testing (TST5328) 117-0331T-08A UL 580 UL 1897 2006 2012 Force Engineering & Testing (TST5328) 117-0331T-08B UL 580 UL 1897 2006 2012 Force Engineering & Testing (TST5328) 117-0331T-08D UL 580 UL 1897 2006 2012 Force Engineering & Testing (TST5328) 117-0337T-10 UL 580 UL 1897 2006 2012 Force Engineering & Testing (TST5328) 117-0378T-11A FM 4471 1992 Force Engineering & Testing (TST5328) 117-0378T-11B FM 4471 1992 Force Engineering & Testing (TST5328) 117-0378T-11C FM 4471 1992 Force Engineering & Testing (TST5328) 117-0407T-09 UL 580 UL 1897 2006 2012 Force Engineering & Testing (TST5328) 117-0407T-09A UL 580 UL 1897 2006 2012 Intertek- West Palm Beach (an ATI company) (TST1527) B9000.01-450-18 UL 580 UL 1897 2006 2012 Intertek- West Palm Beach (an ATI company) (TST1527) C0308.01-450-18 UL 580 UL 1897 2006 2012 Intertek- West Palm Beach (an ATI company) (TST1527) D0818.01-450-18 UL 580 2006 Intertek- West Palm Beach (an ATI company) (TST1527) D1692.01-450-44 UL 580 UL 1897 ASTM E 8
2006 2012
Intertek- West Palm Beach (an ATI company) (TST1527) G7287.01-450-44 UL 580 2006 PRI Construction Materials Technologies (TST5878) 1272T0005 ASTM G 155 2013 PRI Construction Materials Technologies (TST5878) 2292T0001 UL 580 UL 1897 2006 2012 PRI Construction Materials Technologies (TST5878) 2292T0002 UL 580 UL 1897 2006 2012 PRI Construction Materials Technologies (TST5878) 2292T0011 UL 580 UL 1897 2006 2012
A CREEK
Technical Services, LLC
GCS20002.2a FL33818-R2 Page 3 of 6 Page 3 of 23
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein.
GULF COAST SUPPLY & MANUFACTURING, LLC Metal Roofing
PRODUCT DESCRIPTION
GulfLok Profile: 1 in. snap lock seam; Max.16 in. coverage
Description: Non-structural, snap lock standing seam roof panel with 7/8 in. slotted nail strip
Material: Min. 26 ga. ASTM A792 AZ50 or ASTM A653 G90; Optional Fluropon® paint finish; Fy = min. 50 ksi; Shall conform with FBC Section 1507.4.3
Min. 0.032 in. ASTM B209, 3105 H24 aluminum; Optional Fluropon® paint finish; Fy = min. 24 ksi; Shall conform with FBC Section 1507.4.3
GulfSeam Profile: 1 3/4 in. snap lock seam; Max. 18 in. coverage
Description: Non-structural, snap lock standing seam roof panel
Material: Min. 26 ga. ASTM A792 AZ50 or ASTM A653 G90; Optional Fluropon® paint finish; Fy = min. 50 ksi; Shall conform with FBC Section 1507.4.3
Min. 0.032-inch ASTM B209, 3105 H24 aluminum, Optional Fluropon® paint finish; Fy = min. 21 ksi; Shall conform with FBC Section 1507.4.3
MegaLoc Profile: 2 in. mechanical seam; Max. 18 in. coverage
Description: Non-structural, mechanical lock 180º standing seam roof panel
Material: Min. 24 ga. ASTM A792 AZ50 or ASTM A653 G90; Optional Fluropon® paint finish; Fy = min. 50 ksi; Shall conform with FBC Section 1507.4.3
A CREEK
Technical Services, LLC
GCS20002.2a FL33818-R2 Page 4 of 6 Page 4 of 23
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein.
GULF COAST SUPPLY & MANUFACTURING, LLC Metal Roofing
VersaLoc Profile: 1.5 in. mechanical seam; Max. 18 in. coverage
Description: Non-structural, mechanical lock 180º standing seam roof panel
Material: Min. 24 ga. ASTM A792 AZ50 or ASTM A653 G90; Optional Fluropon® paint finish; Fy = min. 50 ksi; Shall conform with FBC Section 1507.4.3
5V Crimp Profile: 7/16 in. ribs at 12 in. o.c.; 24 in. coverage
Description: Non-structural, through fastened roof panel
Material: Min. 26 ga. ASTM A792 AZ50 or ASTM A653 G90; Optional Fluropon® paint finish; Fy = min. 50 ksi; Shall conform with FBC Section 1507.4.3
Min. 0.032 in. ASTM B209, 3105 H24 aluminum; Optional Fluropon® paint finish; Fy = min. 25 ksi; Shall conform with FBC Section 1507.4.3
GulfPBR Profile: 1 1/4 in. ribs at 12 in. o.c.; 36 in. coverage
Description: Non-structural, through fastened roof panel
Material: Min. 26 ga. ASTM A792 AZ50 or ASTM A653 G90; Optional Fluropon® paint finish; Fy = min. 80 ksi; Shall conform with FBC Section 1507.4.3
A CREEK
Technical Services, LLC
GCS20002.2a FL33818-R2 Page 5 of 6 Page 5 of 23
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein.
GULF COAST SUPPLY & MANUFACTURING, LLC Metal Roofing
GulfRib Profile: 3/4 in. ribs at 9 in. o.c.; 36 in. coverage
Description: Non-structural, through fastened roof panel
Material: Min. 29 ga. ASTM A792 AZ50 or ASTM A653 G90; Optional Fluropon® paint finish; Fy = min. 80 ksi; Shall conform with FBC Section 1507.4.3
GulfWave Profile: 3/4 in. corrugation; 29 in. coverage
Description: Non-structural, through fastened roof panel
Material: Min. 26 ga. ASTM A792 AZ50 or ASTM A653 G90; Optional Fluropon® paint finish; Fy = min. 80 ksi; Shall conform with FBC Section 1507.4.3
A CREEK
Technical Services, LLC
GCS20002.2a FL33818-R2 Page 6 of 6 Page 6 of 23
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein.
GULF COAST SUPPLY & MANUFACTURING, LLC Metal Roofing
LIMITATIONS
1. Fire classification is not within the scope of this evaluation. 2. This report is not for use in the HVHZ. 3. The roof deck and the roof deck attachment shall be designed by others to meet the minimum design loads established for components and cladding and in accordance with FBC requirements. 4. Roof slope shall be in accordance with FBC Section 1507.4.2. 5. Reroofing shall be in accordance with FBC Section 1511. Recovery versus replacement shall be evaluated in accordance with FBC Section 1511.3. 6. Installation of the evaluated products shall comply with this report, the FBC and the manufacturer’s published application instructions. Where discrepancies exist between these sources, the more restrictive and FBC compliant installation detail shall prevail. 7. All products listed in this report shall be manufactured under a quality assurance program in compliance with Rule 61G20-3.
COMPLIANCE STATEMENT
The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building Code, 7th Edition (2020) as evidenced in the referenced documents submitted by the named manufacturer.
Zachary R. Priest, P.E. Florida Registration No. 74021 Organization No. ANE9641
CERTIFICATION OF INDEPENDENCE
CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distributing products under this evaluation. CREEK Technical Services, LLC is not owned, operated, or controlled by any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product.
APPENDICES
1) APPENDIX A – Installation (5 pages) 2) APPENDIX B – Approved Roof Systems (7 pages) 3) APPENDIX C – Design Wind Loads (4 pages)
This item has been
digitally signed and
sealed by Zachary R.
Priest, PE, on 10/21/2021.
Printed copies of this
document are not
considered signed and
sealed and the signature
must be verified on any
electronic copies.
2021.10.21
10:40:51
-04'00'
A CREEK
Technical Services, LLC
GCS20002.2a FL33818-R2 Page 1 of 5 Page 1 of 23
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein.
GULF COAST SUPPLY & MANUFACTURING, LLC Metal Roofing
APPENDIX A INSTALLATION
Note - Refer to the APPROVED ROOF SYSTEMS section of this report for specific installation details of a selected system. Unless otherwise specified in this report the following installation details shall be met for the named products:
Component Product Installation Detail
Fasteners
#9-15 HWH wood screw with sealing washer
Shall penetrate through the sheathing a minimum 3/8 in. Shall be corrosion resistant in accordance with FBC section 1507.4.4.
#9-15 HWH WoodZAC screw
#10-12 Pancake Type A screw
#10-14 HWH WoodTite Fastener with sealing washer
#12-11 Pancake Type A screw
#12-8 HWH Woodgrip XG screw with sealing washer
1/4-14 HWH ZAC Impax Lap screw Installed at panel side lap; Shall be corrosion resistant in accordance with FBC section 1507.4.4.
Clips
GulfLok Clip
24 ga. in-seam clip
Fixed Clip
18 ga. in-seam clip
A CREEK
Technical Services, LLC
GCS20002.2a FL33818-R2 Page 2 of 5 Page 2 of 23
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein.
GULF COAST SUPPLY & MANUFACTURING, LLC Metal Roofing
APPENDIX A Component Product Installation Detail
Clips (Cont’d)
NC-33003-3 Sliding Clip
1500SC Sliding Clip
22 ga. top; 16 ga. base; in-seam clip
Sealants TiteBond Weathermaster Metal Roof Sealant Shall be applied in 1/4”- 5/16” continuous beads on the male rib along the seam
Fastening Details
Nomenclature Attachment
GulfLok Type 1
GulfLok Overlap
A CREEK
Technical Services, LLC
GCS20002.2a FL33818-R2 Page 3 of 5 Page 3 of 23
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein.
GULF COAST SUPPLY & MANUFACTURING, LLC Metal Roofing
APPENDIX A Fastening Details
Nomenclature Attachment
GulfLok Type 2
GulfSeam Type 1
MegaLoc Type 1
VersaLoc Type 1
5V Type 1
5V Type 2
A CREEK
Technical Services, LLC
GCS20002.2a FL33818-R2 Page 4 of 5 Page 4 of 23
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein.
GULF COAST SUPPLY & MANUFACTURING, LLC Metal Roofing
APPENDIX A Fastening Details
Nomenclature Attachment
5V Type 3
GulfPBR Type 1
GulfPBR Type 2
GulfRib Type 1
GulfRib Type 2
A CREEK
Technical Services, LLC
GCS20002.2a FL33818-R2 Page 5 of 5 Page 5 of 23
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein.
GULF COAST SUPPLY & MANUFACTURING, LLC Metal Roofing
APPENDIX A Fastening Details
Nomenclature Attachment
GulfRib Type 3
GulfRib Type 4
GulfWave Type 1
A CREEK
Technical Services, LLC
GCS20002.2a FL33818-R2 Page 1 of 8
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein.
GULF COAST SUPPLY & MANUFACTURING, LLC Metal Roofing
APPENDIX B APPROVED ROOF SYSTEMS
The following notes shall be observed when using the assembly tables below. 1. Maximum Design Pressure (MDP) was calculated using a 2:1 margin of safety per FBC Section 1504.9. 2. Refer to LIMITATIONS and sections of this evaluation when using the table(s) below. 3. Refer to INSTALLATION section of this report for installation detail when the information is not explicitly stated for the selected assembly. 4. The on-center (o.c.) spacing given is the maximum allowable attachment spacing for the rated system. 5. The panel thickness or gauge is the minimum allowable. 6. Steel Deck shall be designed by others in accordance with FBC requirements and shall be minimum 22 ga (Fy = min.40 ksi) Wide Rib Deck (Type WR) conforming to ANSI/SDI-RD1.0 & FBC. 7. Wood Deck shall be designed by others in accordance with FBC requirements and shall be minimum 15/32-inch thick APA Span-Rated plywood sheathing at maximum 24-inch span.
Roof System Numbers and Definitions
LOK-W# GulfLok over Wood Deck (New or Existing) SEAM-W# GulfSeam over Wood Deck (New or Existing)
MEGA-W# MegaLoc over Wood Deck (New or Existing)
VL-W# 1.5” VersaLoc over Wood Deck (new or Existing)
5V-W# 5V Crimp over Wood Deck (New or Existing) PBR-W# GulfPBR over Wood Deck (New or Existing) RIB-W# GulfRib over Wood Deck (New or Existing)
WAVE-W# GulfWave over Wood Deck (New or Existing)
Approved Systems for GulfLok over Wood Deck (New or Existing)
System No. Deck Fire Barrier Underlayment Roof Panel Panel Attachment MDP
(psf)
LOK-W-1 Min. 15/32 B-C plywood
OPTIONAL
Approved fire barrier or insulation As required per FBC Min. 0.032” Al GulfLok Max. 16-inch coverage GulfLok Type 1 attachment with #10-12 x 1” Pancake Type A screws spaced 5-3/16 in. o.c. -65.5
LOK-W-2 Min. 15/32 B-C plywood
OPTIONAL
Approved fire barrier or insulation As required per FBC Min. 0.032” Al GulfLok Max. 16-inch coverage
GulfLok Type 1 attachment with #10-12 x 1” Pancake Type A screws spaced 5-3/16 in. o.c. Titebond Weathermaster Metal Roof Sealant applied to male rib.
-116
LOK-W-3 Min. 15/32 CDX plywood
OPTIONAL
Approved fire barrier or insulation As required per FBC Min. 0.040” Al GulfLok Max. 16-inch coverage
GulfLok Type 1 attachment with #10-12 x 1” Pancake Type A screws spaced 6 in. o.c. Female leg snap-fit to male leg with
GulfLok Overlap
-93.5
A CREEK
Technical Services, LLC
GCS20002.2a FL33818-R2 Page 2 of 8
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein.
GULF COAST SUPPLY & MANUFACTURING, LLC Metal Roofing
APPENDIX B Approved Systems for GulfLok over Wood Deck (New or Existing)
System No. Deck Fire Barrier Underlayment Roof Panel Panel Attachment MDP (psf)
LOK-W-4 Min. 15/32 CDX plywood
OPTIONAL
Approved fire barrier or insulation As required per FBC 26 ga. GulfLok Max. 16-inch coverage
GulfLok Type 1 attachment with #10-12 x 1” Pancake Type A screws spaced 5-3/16 in. o.c. Titebond Weathermaster Metal Roof Sealant applied to male rib.
-121.75
LOK-W-5 Min. 15/32 B-C plywood
OPTIONAL
Approved fire barrier or insulation As required per FBC 26 ga., Grade 80 GulfLok Max. 16-inch coverage GulfLok Type 1 attachment #10-12 x 1” Pancake Type A p screws spaced 5-3/16 in. o.c -63.5
LOK-W-6 Min. 15/32 B-C plywood
OPTIONAL Approved fire barrier or insulation As required per FBC 26 ga., Grade 80 GulfLok Max. 16-inch coverage
GulfLok Type 2 attachment with #10-12 x 1” Pancake Type A screws through clip and spaced 5-3/16 in. o.c. -161
LOK-W-7 Min. 15/32 B-C plywood
OPTIONAL
Approved fire barrier or insulation As required per FBC 24 ga. GulfLok Max. 16-inch coverage GulfLok Type 1 attachment with #10-12 x 1” Pancake Type A screws spaced 10-1/4 in. o.c. -81.75
LOK-W-8 Min. 15/32 B-C plywood
OPTIONAL
Approved fire barrier or insulation As required per FBC 24 ga. GulfLok Max. 16-inch coverage GulfLok Type 1 attachment with #10-12 x 1” Pancake Type A screws spaced 5-1/8 in. o.c. -96.75
Approved Systems for GulfSeam over Wood Deck (New or Existing)
System No. Deck Fire Barrier Underlayment Roof Panel Panel Attachment MDP (psf)
SEAM-W-1 Min. 15/32 CDX plywood
OPTIONAL
Approved fire barrier or insulation As required per FBC Min. 0.032” Al GulfSeam Max. 16-inch coverage GulfSeam Type 1 attachment with stainless steel clips spaced 18 in. o.c. -60
SEAM-W-2 Min. 15/32 CDX plywood
OPTIONAL Approved fire barrier or insulation As required per FBC Min. 0.032” Al GulfSeam Max. 16-inch coverage GulfSeam Type 1 attachment with stainless steel clips spaced 6 in. o.c. -75
SEAM-W-3 Min. 15/32 CDX plywood
OPTIONAL
Approved fire barrier or insulation As required per FBC Min. 0.032” Al GulfSeam Max. 18-inch coverage GulfSeam Type 1 attachment with stainless steel clips spaced 18 in. o.c. -86
A CREEK
Technical Services, LLC
GCS20002.2a FL33818-R2 Page 3 of 8
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein.
GULF COAST SUPPLY & MANUFACTURING, LLC Metal Roofing
APPENDIX B Approved Systems for GulfSeam over Wood Deck (New or Existing)
System No. Deck Fire Barrier Underlayment Roof Panel Panel Attachment MDP (psf)
SEAM-W-4 Min. 15/32 CDX plywood
OPTIONAL
Approved fire barrier or insulation As required per FBC Min. 26 ga. GulfSeam Max. 16-inch coverage GulfSeam Type 1 attachment with clips spaced 18 in. o.c. -60
SEAM-W-5 Min. 15/32 CDX plywood
OPTIONAL
Approved fire barrier or insulation As required per FBC Min. 26 ga. GulfSeam Max. 16-inch coverage GulfSeam Type 1 attachment with clips spaced 6 in. o.c. -75
SEAM-W-6
Min. 1x4 No. 2 SYP wood purlins spaced 18 in. o.c. over Min. 15/32 B-C plywood
OPTIONAL
Approved fire barrier or insulation As required per FBC Min. 24 ga. GulfSeam Max. 16-inch coverage GulfSeam Type 1 attachment with clips spaced 18 in. o.c. over wood purlins -93.5
SEAM-W-7 Min. 15/32 B-C plywood
OPTIONAL
Approved fire barrier or insulation As required per FBC Min. 24 ga. GulfSeam Max. 18-inch coverage GulfSeam Type 1 attachment with clips spaced 24 in. o.c. -69.25
SEAM-W-8 Min. 15/32 B-C plywood
OPTIONAL
Approved fire barrier or insulation As required per FBC Min. 24 ga. GulfSeam Max. 18-inch coverage GulfSeam Type 1 attachment with clips spaced 12 in. o.c. -108.5
SEAM-W-9
Min. 1x4 No. 2 SYP wood purlins spaced 24 in. o.c. over Min. 15/32 CDX plywood
OPTIONAL
Approved fire barrier or insulation As required per FBC Min. 24 ga. GulfSeam Max. 18-inch coverage GulfSeam Type 1 attachment with clips spaced 24 in. o.c. over wood purlins -114.25
SEAM-W-10
Min. 1x4 No. 2 SYP wood purlins spaced 12 in. o.c. over Min. 15/32 CDX plywood
OPTIONAL
Approved fire barrier or insulation As required per FBC Min. 24 ga. GulfSeam Max. 18-inch coverage GulfSeam Type 1 attachment with clips spaced 12 in. o.c. over wood purlins -159.25
A CREEK
Technical Services, LLC
GCS20002.2a FL33818-R2 Page 4 of 8
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein.
GULF COAST SUPPLY & MANUFACTURING, LLC Metal Roofing
APPENDIX B
Approved Systems for MegaLoc over Wood Deck (New or Existing)
System No. Deck Fire Barrier Underlayment Roof Panel Panel Attachment MDP (psf)
MEGA-W-1 Min. 15/32 B-C plywood
OPTIONAL
Approved fire barrier or insulation As required per FBC Min. 24 ga. MegaLoc Max. 18-inch coverage MegaLocType 1 attachment with clips spaced 24 in. o.c. -71
MEGA-W-2 Min. 15/32 B-C plywood
OPTIONAL
Approved fire barrier or insulation As required per FBC Min. 24 ga. MegaLoc Max. 18-inch coverage MegaLocType 1 attachment with clips spaced 12 in. o.c. -108.5
Approved Systems for VersaLoc over Wood Deck (New or Existing)
System No. Deck Fire Barrier Underlayment Roof Panel Panel Attachment MDP
(psf)
VL-W-1 Min. 15/32 B-C plywood
OPTIONAL
Approved fire barrier or insulation As required per FBC Min. 24 ga. VersaLoc Max. 16-inch coverage VersaLoc Type 1 attachment with clips spaced 24 in. o.c. -59.75
VL-W-2 Min. 15/32 B-C plywood
OPTIONAL
Approved fire barrier or insulation As required per FBC Min. 24 ga. VersaLoc Max. 16-inch coverage VersaLoc Type 1 attachment with clips spaced 6 in. o.c. -123.5
Approved Systems for 5V Crimp over Wood Deck (New or Existing)
System No. Deck Fire Barrier/ Insulation Underlayment Roof Panel Panel Attachment MDP (psf)
5V-W-1 Min. 15/32 B-C plywood
OPTIONAL
Approved fire barrier or insulation As required per FBC Min. 0.032” Al 5V Crimp 24-inch coverage 5V Crimp Type 1 attachment with #9-15 HWH wood screws with sealing washers spaced 12 in. o.c. -108.5
5V-W-2
OPTIONAL layer of ASTM D 3462 shingles over Min. 15/32 B-C plywood
OPTIONAL
Approved fire barrier or insulation As required per FBC Min. 26 ga. 5V Crimp 24-inch coverage
5V Crimp Type 3 attachment with #10-14 HWH WoodTite Fasteners with sealing washers into wood purlins installed 16 in. o.c. counter to the structural supports and attached with min. 0.113” x 2-3/8” ring shank nails spaced 4 in. o.c. beginning 1 in. from the edge
-75
A CREEK
Technical Services, LLC
GCS20002.2a FL33818-R2 Page 5 of 8
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein.
GULF COAST SUPPLY & MANUFACTURING, LLC Metal Roofing
APPENDIX B Approved Systems for 5V Crimp over Wood Deck (New or Existing)
System No. Deck Fire Barrier/ Insulation Underlayment Roof Panel Panel Attachment MDP (psf)
5V-W-3 Min. 15/32 B-C plywood
OPTIONAL
Approved fire barrier or insulation As required per FBC Min. 26 ga. 5V Crimp 24-inch coverage 5V Crimp Type 3 attachment with #9-15 HWH wood screws with sealing washers spaced 16 in. o.c. -94.25
5V-W-4 Min. 15/32 B-C plywood
OPTIONAL Approved fire barrier or insulation As required per FBC Min. 26 ga. 5V Crimp 24-inch coverage 5V Crimp Type 1 attachment with #9-15 HWH wood screws with sealing washers spaced 12 in. o.c. -108.5
5V-W-5 Min. 15/32 B-C plywood
OPTIONAL Approved fire barrier or insulation As required per FBC Min. 26 ga. 5V Crimp 24-inch coverage 5V Crimp Type 2 attachment with #9-15 HWH wood screws with sealing washers spaced 16 in. o.c. -131
5V-W-6 Min. 15/32 B-C plywood
OPTIONAL Approved fire barrier or insulation As required per FBC Min. 26 ga. 5V Crimp 24-inch coverage
5V Crimp Type 1 attachment with #9-15 HWH wood screws with sealing washers spaced 6 in. o.c. -156.5
Approved Systems for GulfPBR over Wood Deck (New or Existing)
System No. Deck Fire Barrier/ Insulation Underlayment Roof Panel Panel Attachment MDP (psf)
PBR-W-1 Min. 15/32 B-C plywood
OPTIONAL
Approved fire barrier or insulation As required per FBC Min. 26 ga. GulfPBR 36-inch coverage
GulfPBR Type 1 attachment with #9-15 15 HWH WoodZAC screws spaced 24 in. o.c. Laps fastened with 1/4-14 x 7/8” HWH ZAC Impax Lap screws spaced 24 in. o.c.
-60.5
PBR-W-2
Min. 1x4 No. 2 SYP wood purlins spaced 24 in. o.c. over Min. 15/32 B-C plywood
OPTIONAL
Approved fire barrier or insulation As required per FBC Min. 26 ga. GulfPBR 36-inch coverage
GulfPBR Type 1 attachment with #9-15 HWH WoodZAC screws spaced 24 in. o.c. into wood purlins Laps fastened with 1/4-14 x 7/8 ZAC Impax Lap screws spaced 24 in. o.c.
-100.5
A CREEK
Technical Services, LLC
GCS20002.2a FL33818-R2 Page 6 of 8
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein.
GULF COAST SUPPLY & MANUFACTURING, LLC Metal Roofing
APPENDIX B Approved Systems for GulfPBR over Wood Deck (New or Existing)
System No. Deck Fire Barrier/ Insulation Underlayment Roof Panel Panel Attachment MDP (psf)
PBR-W-3
Min. 1x4 No. 2 SYP wood purlins spaced 12 in. o.c. over Min. 15/32 B-C plywood
OPTIONAL
Approved fire barrier or insulation As required per FBC Min. 26 ga. GulfPBR 36-inch coverage
GulfPBR Type 2 attachment with #9-15 15 HWH WoodZAC screws spaced 12 in. o.c. into wood purlins Laps fastened with 1/4-14 x 7/8” HWH ZAC Impax Lap screws spaced 24 in. o.c.
-151.75
PBR-W-4 Min. 15/32 B-C plywood
OPTIONAL
Approved fire barrier or insulation As required per FBC Min. 26 ga. GulfPBR 36-inch coverage
GulfPBR Type 2 attachment with #9-15 HWH WoodZAC screws spaced 12 in. o.c. Laps fastened with 1/4-14 x 7/8” HWH ZAC Impax Lap screws spaced 24 in. o.c.
-154.75
Approved Systems for GulfRib over Wood Deck (New or Existing)
System No. Deck Fire Barrier/ Insulation Underlayment Roof Panel Panel Attachment MDP (psf)
RIB-W-1 Min. 7/16 OSB OPTIONAL
Approved fire barrier or insulation As required per FBC Min. 29 ga. GulfRib 36-inch coverage GulfRib Type 4 attachment with #12-8 HWH Woodgrip XG wood screws with sealing washers spaced 24 in. o.c. -22.66
RIB-W-2 Min. 15/32 CDX plywood
OPTIONAL
Approved fire barrier or insulation As required per FBC Min. 29 ga. GulfRib 36-inch coverage GulfRib Type 3 attachment with #9-15 HWH wood screws with sealing washers spaced 24 in. o.c. -56
RIB-W-3 Min. 15/32 B-C plywood
OPTIONAL
Approved fire barrier or insulation As required per FBC Min. 29 ga. GulfRib 36-inch coverage GulfRib Type 1 attachment with # with #9-15 HWH WoodZAC screws spaced 24 in. o.c -71.75
RIB-W-4
Min. 1x4 No. 2 SYP wood purlins spaced 24 in. o.c. over Min. 15/32 B-C plywood
OPTIONAL
Approved fire barrier or insulation As required per FBC Min. 29 ga. GulfRib 36-inch coverage
GulfRib Type 1 attachment with #9-15 x 1 1/2” HWH wood screws with sealing washers spaced 24 in. o.c. into wood purlins -76.75
A CREEK
Technical Services, LLC
GCS20002.2a FL33818-R2 Page 7 of 8
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein.
GULF COAST SUPPLY & MANUFACTURING, LLC Metal Roofing
APPENDIX B Approved Systems for GulfRib over Wood Deck (New or Existing)
System No. Deck Fire Barrier/ Insulation Underlayment Roof Panel Panel Attachment MDP (psf)
RIB-W-5
Min. 1x4 No. 2 SYP wood purlins spaced 24 in. o.c. over Min. 7/16 OSB
OPTIONAL
Approved fire barrier or insulation As required per FBC Min. 29 ga. GulfRib 36-inch coverage
GulfRib Type 1 attachment with #9-15 x 1 1/2” HWH wood screws with sealing washers spaced 24 in. o.c. into wood purlins -101
RIB-W-6 Min. 15/32 CDX plywood
OPTIONAL
Approved fire barrier or insulation As required per FBC Min. 29 ga. GulfRib 36-inch coverage GulfRib Type 3 attachment with #9-15 HWH wood screws with sealing washers spaced 12 in. o.c. -101
RIB-W-7 Min. 7/16 OSB OPTIONAL
Approved fire barrier or insulation As required per FBC Min. 29 ga. GulfRib 36-inch coverage GulfRib Type 4 attachment with #12-8 HWH Woodgrip XG wood screws with sealing washers spaced 6 in. o.c. -116.0
RIB-W-8
Min. 1x4 No. 2 SYP wood purlins spaced 24 in. o.c. over Min. 15/32 B-C plywood
OPTIONAL
Approved fire barrier or insulation As required per FBC Min. 29 ga. GulfRib 36-inch coverage
GulfRib Type 2 attachment with #9-15 x 1 1/2” HWH wood screws with sealing washers spaced 24 in. o.c. into wood purlins -123.5
RIB-W-9 Min. 15/32 B-C plywood
OPTIONAL
Approved fire barrier or insulation As required per FBC Min. 29 ga. GulfRib 36-inch coverage GulfRib Type 2 attachment with #9-15 HWH wood screws with sealing washers spaced 12 in. o.c. -146.0
RIB-W-10
Min. 1x4 No. 2 SYP wood purlins spaced 24 in. o.c. over Min. 15/32 B-C plywood
OPTIONAL
Approved fire barrier or insulation As required per FBC Min. 26 ga. GulfRib 36-inch coverage GulfRib Type 1 attachment with #9-15 HWH WoodZAC screws spaced 24 in. o.c. into wood purlins -106.75
RIB-W-11 Min. 15/32 B-C plywood
OPTIONAL
Approved fire barrier or insulation As required per FBC Min. 26 ga. GulfRib 36-inch coverage GulfRib Type 2 attachment with #9-15 HWH WoodZAC screws spaced 12 in. o.c. -159.25
A CREEK
Technical Services, LLC
GCS20002.2a FL33818-R2 Page 8 of 8
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein.
GULF COAST SUPPLY & MANUFACTURING, LLC Metal Roofing
APPENDIX B Approved Systems for GulfRib over Wood Deck (New or Existing)
System No. Deck Fire Barrier/ Insulation Underlayment Roof Panel Panel Attachment MDP (psf)
RIB-W-12
Min. 1x4 No. 2 SYP wood purlins spaced 12 in. o.c. over Min. 15/32 B-C plywood
OPTIONAL
Approved fire barrier or insulation As required per FBC Min. 26 ga. GulfRib 36-inch coverage GulfRib Type 1 attachment with #9-15 HWH WoodZAC screws spaced 12 in. o.c. into wood purlins -164.25
Approved Systems for GulfWave over Wood Deck (New or Existing)
System No. Deck Fire Barrier/ Insulation Underlayment Roof Panel Panel Attachment MDP (psf)
WAVE-W-1 Min. 15/32 B-C plywood
OPTIONAL
Approved fire barrier or insulation As required per FBC Min. 26 ga. GulfWave 29-inch coverage
GulfWave Type 1 attachment with #9-15 HWH wood screws with sealing washers spaced 24 in. o.c. -78.5
A CREEK
Technical Services, LLC
GCS20002.2a FL33818-R2 Page 1 of 4
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein.
GULF COAST SUPPLY & MANUFACTURING, LLC Metal Roofing
APPENDIX C
DESIGN WIND LOADS
The following tables provide design wind loads for components and cladding in accordance with Section 1609 of the FBC and ASCE 7-16 under the following provisions: 1. Wind speeds for risk category I, II, III, and IV buildings shall be as defined in Section 1609 of the FBC. 2. Exposure B, C, and D shall be as defined in section 1609 of the FBC. 3. Design wind load provided only for gable/hip roofs with roof slopes between 2:12 and 6.1:12 4. All calculations are based on an effective wind area of 10-ft2 or less. 5. Topographic factors such as escarpments or hills have been excluded from the analysis 6. Overhangs have been excluded from the analysis. 7. Wind directionality factor, Kd = 0.85 8. Vult is shown in the tables below. Design wind loads are calculated using Vasd = Vult√0.6 per 1609.3.1. 9. Zone 2 is inclusive of Zone 2e, Zone 2n, and Zone 2r 10. Zone 3 is inclusive of Zone 3e and Zone 3r 11. Projects with mean roof heights greater than 60-ft shall be evaluated by a licensed design professional 12. Zones 1, 2, and 3 shall be defined as shown below. Dimension “a” shall be 10% of the least horizontal dimension or (0.4 x Mean Roof Height), whichever is smaller, but not less than either 4% of the least horizontal dimension or 3ft
Gable Hip
.
a a a
3 3 a
2 2 1
2 3
a 3
2
a
3
2
2 3
3
1 2
2 3
a a
a
a
a
3
3 2
2
1
1
2 2 1
a
2 2 1
3
3
A CREEK
Technical Services, LLC
GCS20002.2a FL33818-R2 Page 2 of 4
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein.
GULF COAST SUPPLY & MANUFACTURING, LLC Metal Roofing
APPENDIX C
Gable/Hip Roofs in Exposure B (Roof slope between 2:12 and 12:12)
Building Type Zone Mean Roof Height (ft)
Basic Wind Speed (mph)
120 130 140 150 160 170 180 190 200
Enclosed/ Partially Open
1
20 -25.4 -29.8 -34.6 -39.7 -45.2 -51.0 -57.2 -63.7 -70.6
25 -27.5 -32.2 -37.4 -42.9 -48.8 -55.1 -61.8 -68.8 -76.3
30 -28.7 -33.7 -39.1 -44.8 -51.0 -57.6 -64.6 -71.9 -79.7
40 -31.2 -36.6 -42.4 -48.7 -55.4 -62.5 -70.1 -78.1 -86.5
50 -33.2 -39.0 -45.2 -51.9 -59.0 -66.6 -74.7 -83.2 -92.2
60 -34.8 -40.9 -47.4 -54.4 -61.9 -69.9 -78.4 -87.3 -96.8
2
20 -37.1 -43.5 -50.5 -57.9 -65.9 -74.4 -83.4 -92.9 -103.0
25 -40.1 -47.0 -54.5 -62.6 -71.2 -80.4 -90.1 -100.4 -111.3
30 -41.9 -49.1 -57.0 -65.4 -74.4 -84.0 -94.2 -104.9 -116.3
40 -45.4 -53.3 -61.9 -71.0 -80.8 -91.2 -102.2 -113.9 -126.2
50 -48.4 -56.8 -65.9 -75.7 -86.1 -97.2 -109.0 -121.4 -134.5
60 -50.8 -59.6 -69.2 -79.4 -90.3 -102.0 -114.3 -127.4 -141.2
3
20 -44.1 -51.7 -60.0 -68.8 -78.3 -88.4 -99.1 -110.5 -122.4
25 -47.6 -55.9 -64.8 -74.4 -84.7 -95.6 -107.1 -119.4 -132.3
30 -49.8 -58.4 -67.7 -77.7 -88.4 -99.8 -111.9 -124.7 -138.2
40 -54.0 -63.4 -73.5 -84.4 -96.0 -108.4 -121.5 -135.4 -150.0
50 -57.6 -67.6 -78.4 -90.0 -102.3 -115.5 -129.5 -144.3 -159.9
60 -60.4 -70.9 -82.2 -94.4 -107.4 -121.2 -135.9 -151.4 -167.8
Partially Enclosed
1
20 -29.7 -34.9 -40.5 -46.5 -52.8 -59.7 -66.9 -74.5 -82.6
25 -32.1 -37.7 -43.7 -50.2 -57.1 -64.5 -72.3 -80.5 -89.2
30 -33.6 -39.4 -45.7 -52.4 -59.7 -67.4 -75.5 -84.1 -93.2
40 -36.4 -42.8 -49.6 -56.9 -64.8 -73.1 -82.0 -91.3 -101.2
50 -38.8 -45.6 -52.9 -60.7 -69.0 -77.9 -87.4 -97.4 -107.9
60 -40.8 -47.8 -55.5 -63.7 -72.4 -81.8 -91.7 -102.2 -113.2
2
20 -41.4 -48.6 -56.3 -64.7 -73.6 -83.1 -93.1 -103.7 -115.0
25 -44.7 -52.5 -60.9 -69.9 -79.5 -89.8 -100.6 -112.1 -124.2
30 -46.7 -54.8 -63.6 -73.0 -83.1 -93.8 -105.1 -117.1 -129.8
40 -50.7 -59.5 -69.0 -79.3 -90.2 -101.8 -114.1 -127.2 -140.9
50 -54.1 -63.4 -73.6 -84.5 -96.1 -108.5 -121.6 -135.5 -150.2
60 -56.7 -66.6 -77.2 -88.6 -100.9 -113.9 -127.6 -142.2 -157.6
3
20 -48.4 -56.8 -65.8 -75.6 -86.0 -97.1 -108.8 -121.3 -134.4
25 -52.3 -61.4 -71.2 -81.7 -92.9 -104.9 -117.6 -131.1 -145.2
30 -54.6 -64.1 -74.3 -85.3 -97.1 -109.6 -122.9 -136.9 -151.7
40 -59.3 -69.6 -80.7 -92.7 -105.4 -119.0 -133.4 -148.7 -164.7
50 -63.2 -74.2 -86.0 -98.8 -112.4 -126.8 -142.2 -158.4 -175.6
60 -66.3 -77.8 -90.3 -103.6 -117.9 -133.1 -149.2 -166.3 -184.2
A CREEK
Technical Services, LLC
GCS20002.2a FL33818-R2 Page 3 of 4
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein.
GULF COAST SUPPLY & MANUFACTURING, LLC Metal Roofing
APPENDIX C
Gable/Hip Roofs in Exposure C (Roof slope between 2:12 and 12:12)
Building Type Zone Mean Roof Height (ft)
Basic Wind Speed (mph)
120 130 140 150 160 170 180 190 200
Enclosed/ Partially Open
1
20 -36.9 -43.3 -50.2 -57.6 -65.6 -74.0 -83.0 -92.5 -102.5
25 -38.5 -45.2 -52.4 -60.2 -68.5 -77.3 -86.7 -96.6 -107.0
30 -40.2 -47.1 -54.7 -62.8 -71.4 -80.6 -90.4 -100.7 -111.6
40 -42.6 -50.0 -58.0 -66.6 -75.8 -85.6 -95.9 -106.9 -118.4
50 -44.7 -52.4 -60.8 -69.8 -79.4 -89.7 -100.5 -112.0 -124.1
60 -46.3 -54.4 -63.0 -72.4 -82.3 -93.0 -104.2 -116.1 -128.7
2
20 -53.8 -63.2 -73.2 -84.1 -95.7 -108.0 -121.1 -134.9 -149.5
25 -56.2 -66.0 -76.5 -87.8 -99.9 -112.8 -126.5 -140.9 -156.1
30 -58.6 -68.8 -79.8 -91.6 -104.2 -117.6 -131.8 -146.9 -162.8
40 -62.2 -73.0 -84.6 -97.2 -110.5 -124.8 -139.9 -155.9 -172.7
50 -65.2 -76.5 -88.7 -101.8 -115.9 -130.8 -146.6 -163.4 -181.0
60 -67.6 -79.3 -92.0 -105.6 -120.1 -135.6 -152.0 -169.4 -187.7
3
20 -64.0 -75.1 -87.1 -99.9 -113.7 -128.4 -143.9 -160.3 -177.7
25 -66.8 -78.4 -90.9 -104.4 -118.8 -134.1 -150.3 -167.5 -185.6
30 -69.7 -81.7 -94.8 -108.8 -123.8 -139.8 -156.7 -174.6 -193.5
40 -73.9 -86.7 -100.6 -115.5 -131.4 -148.3 -166.3 -185.3 -205.3
50 -77.5 -90.9 -105.4 -121.0 -137.7 -155.5 -174.3 -194.2 -215.2
60 -80.3 -94.3 -109.3 -125.5 -142.8 -161.2 -180.7 -201.3 -223.1
Partially Enclosed
1
20 -43.2 -50.6 -58.7 -67.4 -76.7 -86.6 -97.1 -108.2 -119.9
25 -45.1 -52.9 -61.3 -70.4 -80.1 -90.4 -101.4 -113.0 -125.2
30 -47.0 -55.1 -64.0 -73.4 -83.5 -94.3 -105.7 -117.8 -130.5
40 -49.9 -58.5 -67.9 -77.9 -88.6 -100.1 -112.2 -125.0 -138.5
50 -52.3 -61.3 -71.1 -81.7 -92.9 -104.9 -117.6 -131.0 -145.2
60 -54.2 -63.6 -73.7 -84.7 -96.3 -108.7 -121.9 -135.8 -150.5
2
20 -60.1 -70.5 -81.8 -93.9 -106.8 -120.6 -135.2 -150.6 -166.9
25 -62.7 -73.6 -85.4 -98.0 -111.5 -125.9 -141.2 -157.3 -174.3
30 -65.4 -76.8 -89.0 -102.2 -116.3 -131.3 -147.2 -164.0 -181.7
40 -69.4 -81.5 -94.5 -108.5 -123.4 -139.3 -156.2 -174.0 -192.8
50 -72.8 -85.4 -99.0 -113.7 -129.3 -146.0 -163.7 -182.4 -202.1
60 -75.4 -88.5 -102.7 -117.8 -134.1 -151.4 -169.7 -189.1 -209.5
3
20 -70.2 -82.4 -95.6 -109.7 -124.8 -140.9 -158.0 -176.0 -195.1
25 -73.3 -86.1 -99.8 -114.6 -130.4 -147.2 -165.0 -183.9 -203.7
30 -76.5 -89.7 -104.1 -119.5 -135.9 -153.5 -172.0 -191.7 -212.4
40 -81.1 -95.2 -110.5 -126.8 -144.3 -162.9 -182.6 -203.4 -225.4
50 -85.0 -99.8 -115.8 -132.9 -151.2 -170.7 -191.4 -213.2 -236.2
60 -88.2 -103.5 -120.0 -137.8 -156.7 -177.0 -198.4 -221.0 -244.9
A CREEK
Technical Services, LLC
GCS20002.2a FL33818-R2 Page 4 of 4
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein.
GULF COAST SUPPLY & MANUFACTURING, LLC Metal Roofing
APPENDIX C
Gable/Hip Roofs in Exposure D (Roof slope between 2:12 and 12:12)
Building Type Zone Mean Roof Height (ft)
Basic Wind Speed (mph)
120 130 140 150 160 170 180 190 200
Enclosed/ Partially Open
1
20 -44.3 -52.0 -60.3 -69.2 -78.7 -88.8 -99.6 -111.0 -123.0
25 -45.9 -53.9 -62.5 -71.7 -81.6 -92.1 -103.3 -115.1 -127.5
30 -47.5 -55.8 -64.7 -74.3 -84.5 -95.4 -107.0 -119.2 -132.1
40 -50.0 -58.7 -68.1 -78.1 -88.9 -100.4 -112.5 -125.4 -138.9
50 -52.1 -61.1 -70.9 -81.3 -92.5 -104.5 -117.1 -130.5 -144.6
60 -53.7 -63.0 -73.1 -83.9 -95.5 -107.8 -120.8 -134.6 -149.1
2
20 -64.6 -75.8 -87.9 -100.9 -114.8 -129.6 -145.3 -161.9 -179.4
25 -67.0 -78.6 -91.1 -104.6 -119.0 -134.4 -150.7 -167.9 -186.0
30 -69.4 -81.4 -94.4 -108.4 -123.3 -139.2 -156.0 -173.9 -192.6
40 -72.9 -85.6 -99.3 -114.0 -129.7 -146.4 -164.1 -182.9 -202.6
50 -75.9 -89.1 -103.3 -118.6 -135.0 -152.4 -170.8 -190.4 -210.9
60 -78.3 -91.9 -106.6 -122.4 -139.2 -157.2 -176.2 -196.3 -217.6
3
20 -76.8 -90.1 -104.5 -119.9 -136.5 -154.0 -172.7 -192.4 -213.2
25 -79.6 -93.4 -108.3 -124.4 -141.5 -159.7 -179.1 -199.5 -221.1
30 -82.4 -96.8 -112.2 -128.8 -146.6 -165.4 -185.5 -206.7 -229.0
40 -86.7 -101.8 -118.0 -135.5 -154.1 -174.0 -195.1 -217.4 -240.8
50 -90.3 -105.9 -122.8 -141.0 -160.5 -181.1 -203.1 -226.3 -250.7
60 -93.1 -109.3 -126.7 -145.5 -165.5 -186.8 -209.5 -233.4 -258.6
Partially Enclosed
1
20 -51.8 -60.8 -70.5 -80.9 -92.1 -103.9 -116.5 -129.8 -143.8
25 -53.7 -63.0 -73.1 -83.9 -95.5 -107.8 -120.8 -134.6 -149.2
30 -55.6 -65.3 -75.7 -86.9 -98.9 -111.6 -125.1 -139.4 -154.5
40 -58.5 -68.7 -79.6 -91.4 -104.0 -117.4 -131.6 -146.6 -162.5
50 -60.9 -71.5 -82.9 -95.1 -108.2 -122.2 -137.0 -152.6 -169.1
60 -62.8 -73.7 -85.5 -98.1 -111.7 -126.0 -141.3 -157.5 -174.5
2
20 -72.1 -84.6 -98.1 -112.6 -128.2 -144.7 -162.2 -180.7 -200.2
25 -74.8 -87.7 -101.7 -116.8 -132.9 -150.0 -168.2 -187.4 -207.6
30 -77.4 -90.9 -105.4 -121.0 -137.6 -155.4 -174.2 -194.1 -215.1
40 -81.4 -95.6 -110.8 -127.2 -144.8 -163.4 -183.2 -204.1 -226.2
50 -84.8 -99.5 -115.4 -132.4 -150.7 -170.1 -190.7 -212.5 -235.5
60 -87.4 -102.6 -119.0 -136.6 -155.4 -175.5 -196.7 -219.2 -242.9
3
20 -84.3 -98.9 -114.7 -131.7 -149.8 -169.1 -189.6 -211.3 -234.1
25 -87.4 -102.6 -118.9 -136.5 -155.4 -175.4 -196.6 -219.1 -242.7
30 -90.5 -106.2 -123.2 -141.4 -160.9 -181.6 -203.6 -226.9 -251.4
40 -95.2 -111.7 -129.6 -148.7 -169.2 -191.0 -214.2 -238.6 -264.4
50 -99.1 -116.3 -134.9 -154.8 -176.2 -198.9 -223.0 -248.4 -275.2
60 -102.2 -120.0 -139.1 -159.7 -181.7 -205.1 -230.0 -256.2 -283.9
This table is not to
be used.
MJ6.17.2022
1N*
TrI r~ 11.4011r Registry No. 29824
TR s 17520 Edinburgh Dr
Tampa, FL 33647
8 r)480-3421
EVALUATION REPORT FLORIDA BUILDING CODE,7"EDITION(2020)
Manufacturer: GULF COAST SUPPLY&MANUFACTURING,LLC Issued October 21, 2021
14429 SW 2nd Place,Suite G30
Newberry, FL JZooa
352)498-7852
WhAni —i M
Manufacturing Locations: Alachua, FL
Sebring, FL
Montgomery,AL
Quality Assurance: PRI Construction Materials Technologies, LLC (QUA9110)
SCOP..
Category: Rooting
Subcategory:Metal Roofing
Code Edition: Florida Building Code, 7th Edition (2020) High-Velocity Hurricane Zones(HVHZ)
Code Sections: 1518.9.1, 1523.1.1, 1523.6.5, 1523.6.5.2.4, 1523.6.5.2.4.1
Properties: Wind Resistance
RCrCREIe,co
Entity Report No. Standard Year
Architectural Testing, Inc.(TST1527) 69000.01-450-18 TAS 125 2003
Farabaugh Engineering&Testing, Inc.(TST1654) T126-07 TAS 100 1995
Farabaugh Engineering&Testing, Inc.(TST1654) T128-07 TAS 100 1995
Farabaugh Engineering&Testing,Inc.(TST1654) T129-07 TAS 100 1995
Farabaugh Engineering&Testing, Inc.(TST1654) T130-07 TAS 100 1995
Farabaugh Engineering&Testing,Inc.(TST1654) T132-07 TAS 100 1995
Farabaugh Engineering&Testing, Inc.(TST1654) T215-08 TAS 100 1995
Farabaugh Engineering&Testing Inc. (TST1654) T270-08 TAS 100 1005
Farabaugh Engineering&T_stnV., Inc.(TST1654) T271-08 TAS 100 1995
Farnhorrnh Engineering R Tcctinn Inc,(TCT1654) T272-0R TAC 100 1995
Fnraahariestinn1 iii,. (TST16 4) T273-fl TAS 100 1qG.
Farabaugh Engineering&Testing, Inc.(TST1654) T356-10 TAS 100 1995
Force Engineering&Testing(TST5328)72-0313T-06A-C TAS 125 2003
Force Engineering&Testing(TST5328)72-0198T-07A-C TAS 125 2003
Force Engineering&Testing(TST5328)117-0062T-07A-C TAS 125 2003
Force Engineering&Testing(TST5328)117-0062T-07D-F TAS 125 2003
Force Engineering&Testing(TST5328)117-0062T-07G-1 TAS 125 2003
Force Engineering&Testing(TST5328) 117-0062T-07J-L TAS 125 2003
Force Engineering&Testing(TST5328)117-0065T-07A-C TAS 125 2003
Force Engineering&Testing(TST5328)117-0238T-09D FM 4471 1992
Fisrce Engineering,i Testing(av 5,t_L)) FM 4471
Force Engineering&Testing(TST5328) 117-0238T-11A FM 4471 1992
Force Engineering&Testing(TST5328) 117-0378T-11A FM 4471 1992
Force Engineering&Testing(TST5328)117-0378T-11B FM 4471 1992
Force Engineering&Testing(TST5328)117-0378T-11C FM 4471 1992
PRI Construction Materials Technologies(TST5878) HTL-018-02-01 TAS 100 1995
PRI Construction Materials Technologies(TST5878) 1272T0002 ASTM B 117 2016
TAS 110 2000
PRI rnnstnlrtinn Materials Tar•.hnnlnnies(TST5R7R) 1272T0003 ASTM R 117 2016
FAs ' n;
PRI Construction Materials Technologies(TST5878) 1272T0005 ASTM G 155 2013
TOC 110 Jong
PRI Construction Materials Technologies(TST5878) 1272T0006 ASTM G 155 2013
TAS 110 2000
GCS20002.2b FL33818-R2 Page 1 of 4
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation,recommended use, or other product attributes that are not
specifically addressed herein.
By Mike Jones at 11:28 am, Jun 07, 2022
Oil G R E E K GULF COAST SUPPLY&MANUFACTURING, LLC
MefM!Rnnfing/FIVH7i
TECHNICAL SERVICES,LLC
PRODUCT DESCRiPTION
GulfLok Profile: 1 in.snap lock seam;Max.16 in.coverage
Description: Non-structural. snap lock standing seam roof panel with 7/8 in.slotted nail strip
Material:Min.26 ga.ASTM A792 AZ50 coated with Florupon®or ASTM A653 G90;
min.50 ksi; Shall conform with FBC Section 1507A.3
a
11
12"and 16" Coverage
I
VersaLoc Profile: 1.5 in.mechanical seam; Max. 18 in.coverage
Description: I Non-structural,mechanical lock 180°standing seam roof panel
Material: r Min.24 ga.ASTM A792 AZ50 coated with Florupon®or ASTM A653 G90;
F =min.50 ksi; Shall conform with FBC Section 1507. 4.3
I
lin-I1
iT8" 18"Covarayu
5V Crimp 4 Profile: 7/16 in. ribs at 12 in.o.c.;24 in.coverage
Description Non-structural,through fastened rnnf panel
Material:Min. 26 ga.ASTM A792 AZ50 coated with Florupon®or ASTM A653 G90;
Fy=min.50 ksi; Shall conform with FBC Section 1507.4.3
Min.0.032 in.ASTM B209,3105 H24 aluminum; Optional Florupon®paint finish;
I Fy=min.25 ksi; Shall conform with FBC Section 1507.4.3
7/16"t 12"
24"Coverage
GCS20002.2b FL33818-R2 Page 2 of4
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation,recommended use,or other product attributes that are not
specifically addressed herein.
C R E E KGULF COAST SUPPLY&MANUFACTURING,LLC
Mut*i Rnnfinn(HvH7)
TECHNICAL SERVICES, LLC
GuIfPBR Profile:1 1/4 in. ribs at 12 in.o.c.; 36 in. coverage
Description: ! Non-structural,through fastened roof panel
Material: ; Min. 26 ga.ASTM A792 AZ50 coated with Florupon®or ASTM A653 G90;
FY=min. 80 ksi; Shall conform with FBC Section 1507.4.3
1"4"12"
36"Coverage
GulfRib Profile: 3/4 in. ribs at 9 in.o.c.; 36 in. coverage
Description: Non-structural, through fastened roof panel
Material: i Min.29 ga.ASTM A792 AZ50 coated with Florupon(E)or AS I M A653 G90;
FY=min. 80 ksi; Shall conform with FBC Section 1507.4.3
3/4"#
36" Coverage
GCS20002.2b FL33818-R2 Page 3 of 4
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services. LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report dues not express nor imply warranty, installation, recommended use,or other product attributes that are not
specificaiiy addressed herein.
MI CREEK GULF COAST SUPPLY&MANUFACTURING,LLC
Metal Rnnfinn(14VW7)
TECHNICAL SERVICES, LLC
LIMITATIONS
1. Fire classification is not within the scope of this evaluation.
2. The roof deck and the roof deck attachment information are provided based on testing. FBC requirements
for the rational design of the roof deck, including the attachment, are not within the scope of this
evaluation.
3. Roof slope shall be 2:12 or greater.
4. Reroofing shall be in accordance with Section 1521.
5. Installation of the evaluated products shall comply with this report, RAS 133and the manufacturer's
published application instructions. Where discrepancies exist between these sources, the more restrictive
and FBC compliant installation detail shall prevail.
6. All products listed in this report shall be manufactured under a quality assurance program in compliance with
Rule 61G20-3.
COMPLIANCE STATEMENT
The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building
nrlr 7th Frnti.. /2N17m H.h_Vc!nrify H irrir7Inn 7nnec (HVH7) nvirinncnri in the refe nr!rIn nta ihrnittp(1
by rhe n ed m factu.uy uro,iaii,cu n,ai,u,a rw cr.
R.
s
1111 l t i, !
I
Gip. , ,p,Qi,•••This item has been
digitally signed andGENg.`,V.•. sealed by Zachary R. 2021 .1 0.21
No 74021 Priest,PE,on 10/21/2021. ,7?! / I .A D.t1Iy7s(`' C ' : :.1.'+J.1.1I1PrintaritOpiccn!this L17.",
rlr rr ment era not t r tn
r. rw rr- •-•r- • .,1 i P' netwirioreR cinnori anr4 i 14-41.r
sealed and the signaturecP••: achary R. Priest, P. E.s. O R t O,.• ` must be verified on any Florida Registration No. 74021eie0;S;ONA; `` electronic copies. Organization No.ANE9641
CERTIFICATION OF INDEPENDENCE
CREEK Technical Services, LLC does not have,nor will itacquire;a financial interest in any company manufacturing or di.stributing
products under this evaluation.
CREEK Technical Services,LLC is not owned,operated,or controlled by any company manufacturing or distributing products under
this evaluation.
Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products
under this evaluation.
Zachary R.Priest,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the
product.
aarrr nnqrrq
1) APPENDIX A—Installation (3 pages)
2) APPENDIX B—Approved Roof Systems(4 pages)
3) APPENDIX C—Design Wind Loads(3 pages)
GCS20002.2b FL33818-R2 Page 4 of 4
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation,recommended use, or other product attributes that are not
specificaiiy addressed herein.
CREEK GULF COAST SUPPLY&MANUFACTURING,LLC
Mofn!Rnnfinn WW1
TECHNICAL SERVICES, LLC
AoocNnIX A
INSTALLATION
Note-Refer to the APPROVED ROOF SYSTEMS section of this report for specific installation details of a selected system.
Unless otherwise specified in this report the following installation details shall be met for the named products:
1 Component + Product installation Detail
4-95 HWH vw)od screw i I
with sealing washer
i/9-i5 HWH WuoUZAC• i
screw I Shall penetrate through the sheathing a minimum 3/8 in. Shall be corrosion
10- 12 Pancake Type A resistant in accordance with FBC section 1507.4.4.
Fasteners screw
12-11 Pancake Type A
screw
1/4-14 HWH ZAC Impax Installed at panel side lap;Shall be corrosion resistant in accordance with FBC
Lap screw section 1`07.4. 4.
I
24 ga.in-seam clip
I I
GulfLok
14.1f4- t
r' Ls
Clips
1 0.78 ••--
4-1/4"
2"
NC-33003-3 Sliding Clip
Fri—J
n n
TSeaiantsMetal
d amzaster
Shaii be applied in 1i4"-5i16"continuous beads on the maie rib aiong the seamIMetalRoofSealant
GCS20002.2b FL33818-R2 Page 1 of 3
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services.LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specificaiiy addressed herein.
ICREEK GULF COAST SUPPLY&MANUFACTURING,LLC
Mpf Printing(i-iviv)
TECHNICAL SERVICES, LLC ADpCAt111V A
Fastening Details
Nomenclature Attachment
I' MAX. 16" COVERAGE- r
I
Gu Lok Type.I ( i
i
P
a
1) #10-12 X 1"TYPE A PANCAKE
1 i ter-ulFJ.iN CLIP c CAA.
1 GulfLok Type 2 T/I 11_ _ 1
I I
1
1) #10-12 X 1" TYPE A PANCAKE
1'
ri
Max. 18" ir
i i
Vers&LUG Type 1
IIT
LI!
1500SC SLIDING CLIP
2) #12-11 x 1"Panhead per Clip
ilf"---‘4
41 N/1 4 r . _ 4 4 In!! 1 1tA/1 _-_IF1 __1! -- %w/_ _1_ _ _
I I ) rr - Iii X I - TIC. I 'will I yyi.)c_nIIIIij uvn I!I
5V Type 1 12t14or 1 211
q
At Panel Lap
Ai Panel Lap—
1/4-14
ap#
1(4-14 x /Al"Lap Screw 24'U.L. Max.
12" 12" 1 12"
GuIfPBR Type 1
Tht"------------//—\
1°
1)#9-15 x 1-112"
GCS20002.2b FL33818-R2 Page 2 of 3
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This ewaivation report does nrA express nor irnpiy warranty,installation,recommended use, or other product attributes that are not
specifically addressed herein.
CR F F K GULF COAST SUPPLY&MANUFACTURING,LLC
Maarannling/141/1471
TECHNICAL SERVICES, LLC APP=N DIY A
Fastening Details
Nomenclature Attachment
1/4-14 x 7/8"Lap Screw @ 24"O.C. Max.
l—5" ! 7" I 5" Jr 7. f 5,, a 7" 41\5"--sr
t is
I GuIfPBR Type 2 t i i I ;. i
1)#9-15x1-1/2"
T r S
i 1 At Panel tap\1
ulfRib
L(1)#9.15 x 1- 1/2•w/Sealer Washer
t
i6.5"12.5"-f--6.5"--'-, 2.5"-f--6.5"--1-2.5"1-5.5"--1.-2.5'17+' +-------
1- 1/2"
i ii 17-. 1 i iGelfRibType2
I 1 -
w/Sealer Washer
GCS20002.2b FL33818-R2 Page 3 of 3
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services.LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use,or other product attributes that are not
specifically addressee herein.
1 {i. GULF COAST 8U' LY&MANUFACTURING,LLCREEl'C '^ Metal Roofing(HV'HZ)
TIE:oHNICAL SERA/I,::EES, LLC
APPENDIX B
APPROVED ROOF SYSTEMS
The following notes shall he observed when using the assembly tables below.
1. Maximum Design Pressur+ (MDP)was calculated using a 2:1 margin of safety per FBC Section 1523.4.
2. Refer to LIMITATIONS and sections of this evalLaticn when using the tatle(s) below.
3. Refer to INsTALLATIQn section of this report for installation detail when the information is not explicitly stated for the selected assembly.
4. The on-center(o.c.)spacing given is the maxi-num allowable attachment spacing for the rated system.
5. Luderlayment shall be installed in accordance with FBC requirements. The minimum underlayment shall be ASTM D 2:i6, Type II installed as described
in FBC Section 1518.2.1 with hails and tin caps per 1517.5.
6. Steel Deck shall be designed by others in accordance with FBC requiremen:s and shall be m.nirnurn 22 ga (Fy=min.410 ksi)Wide Rib Deck(Type WR)
conforming to ANSI/SDI-RD1.0& FBC. In no case shall the panels be installed on less than 1wa continuous spans,which are spaced a maximum 5-ft o.c.
At minimum,the decl' shall be attached with one (1)#12 x 1.5-inch I-M1H self-drilling screws at the bottom of each flute,,maxaimuh,.6-inch o.c. alDncl the
support). At minimum,the deck side laps sha I be fastened a maximur-t 6-inch o,c.with#12 x 1 5-inch HWH self-drilling screws,
7. Wood Deck shall be designed by others in accordance with FBC requirements and shall be minimum 19/32-inch this APA Span-Rated plywood
sheathing or wood plank M maximum 24-inch span for new construction. Existing constructio 1 s•aall be the minimum plywood sheathing or wood plank
thickness at maximum 24-inch span as stated in the approval tables on following pages. In no case shall the attachmeit be less than 8d ring shank nails
spaced 6-inch o.c.
Roof System Numbers and Definitions _
Y
LOK-W# GulfLok over Wood Dec,:(New or Existing)
VL-W# _ 1.5"VersaLoc over Wood Deck(new or Existing)
5V-W# By Crim.over Wood D--ak(New or Existing)
PBR-W# GuIfPBR over Wood DeckjNew or Existing]_ __ --.
RIB-W# GulfRib over Wood Deck(New or Existing)_
w
Approved Systems for GulfLalk over Wood Deck(New or Existing) w.-
Sy:atcarr' Deck Fire Barrier ll nderlayment Roof Panel Panel Attaachrnent MOP
PJo.psi)
rOPTIONAL
w.wM e3uffLok Type 1 attachment with#10- 12 x T'
LOl' W1
Min. 15/32 MinAX?droved fire barrier As required per FBC 26 ga.GulfLok Pancake Type A screw:3 spaced 5-3/16 in.o.c. -121,75CDXplywood
r insulation Max. 18-inch coverage Titebond Weathermasi er Metal Roof Sealant
applied to male rib.
µMin. 15/32
OPTIONAL
Y 26 da,Grade 80 GulfLck GulfLok Type 1 attachment #1Q-12 x1"LOK;W..2 Apdroved fire barrier As required per FBC 63x,5 B-C
plywood x Insulation Max. 18-inch coverage Pancake Type A screws sperued 5.3/16 in.o.
c OPTIONAL GulfLok Type 2 attachment
with
M I-.OK;W••3 Min. 15/32 Apa.,rovedfire barrier As required per FBC 26 ga.,Grade 80 Gulfl_c k 410-12 x 1"Pancake Type A screws through -161 B-C plywood r Insulation Max. 18-inch coverage clip and spaced 5-3/16 in.o.
c.GC 211002.E:b FI.3381E3 2 Foga1 of
4 This evaluation report is provided for Stote of Florida product srpproval under Rule 61G20-3. The manufacturer shall not t/CREEK Technical Seivices,LLC of any product changes
or quallly assurance changes througrrout the duration for which this report Is valid. This evaluation report does not express nor Imply warranty, installat:on, recommended uss,or
other product at:r butes that are not specificalt/addressed
u ' 'REEK:C"'REEK COAST SUPPLY MANUFACTURING,1.1..0"
3 " ..., Metal Roofing(H0/HZ)
TECHNICAL SERVICES, LLC
APPENDIX B
Approved Systems for VersaLoc over Wood Deck(New or Existing)w —
SystemMl a ADeckIrireBarrier1irderlaymentRoofPanelPanelAtlaachn1ent
it12;0
Min. 15/32 OP71ONAL Miry.24 ga.VersaLoc VersaLoc Type 1 eittadhhnentL-W-1 B-C I Approvedfire barrier As required per FBC 59 1'5plywoodrInsulationMax. 16-inch coverage with clips spaced;;114 in,o.c.
Min. 15/32
1 ^`MdPTioNAL Min.24 ya.VersaLoc --_ ..._ VersaLoc Type? 1 rattatihlnentJL-W-2 B-C plywood Aire roved fire barrier As rrrqulrect per FBC Max. 10-inch coverage with clips spiced r3 in.0.c. 12:3.5
or Insulation
Approved)Systems for 5V Cririp over Wood Deck(New or Existing) N M
Sy,_,tem ire Barrier/MOP
No,
Deck
nsulation
Unde>rlayMent Roof Panel Panel Attachment tl'ts )
OPTIONALMin. 15/32 Min.26 ge,5V Crimp 5V Cdr.v7o Type 1 attachment with t'`.)=15 HWH woodECJW-1 B-C plywood
Approved fire barrier As required per FBC
24-inch coverage screws with sealing washers spored 12 in.o.c. 106'9
or Insulation
OPTIONAL
iV W ? Min. 15/32 Aper'uved fire barrier As rewired per FBC Min.26 pa.5V Crimp 5V Crir;o Type 1 attachment v/ith#9=15 HWH wood _156 9B-C plywood or Insulation 24-inch coverage screws with sealing washers spaced 8 in.o.c.
i--_— W
Approved Syet ms for GuIfPE IR over Wood Deck(Newor't casting) uK
System t=re Barrier/MDP
No.
Deck
insulation
Undadayment hoof Panel Panel Attachment
pa-)
OPTIONALGuifRet?Type 1 attachment with#7-15 '15 HWH WoodZAC
Min. 15/32 Min.26 pa,GuIfPBR screws spaced 24 in.c. c.PEIh-VV-I Ap,a wed fire barrier 4:.required L)er FBC pr Ei0.5B-C plywood
cr Insulation 3E1-inch coverage Laps fastened With 1/4-14 x 7/8" HV!H ZAC Impax Lap
screws spaced 2:4 in.c. c.
GC520002.2.b FL3_,81 El•R2 Page 2 of 4
This evaluation report is provided for SI<,te of Florida product approval under Rule 61G20.3. The manufacturer shall notify CREEK Technical.€€vices, LLC of any product:changes or
quality assurance changes throughout the duration for which this report Is valid. This.svaivation report does not express nor Imply warranty,installat on, recommended u.;e,or other
product attributes that are not specifically addressed herein.
iG u GULF COAST SUPPLY&MANUFACTURING,LLC
1N "..+ i+j Metal Rooiiny(HVnH2)
TECHNICAL SERVI E'B, LLC
APPENDIX B
Approved Systems for GUIfPENiR over Wood Deck(New or f oisting)
5y:=tem Deck F=ire Barrier/MOP
No. IrllUlgtion Uricierlayrnent ROO/Panel Panel Attachment
palN
Min. 1x4 No.2
SYP wood GurtPI3R Type 1 attachment with 49-1:i HWF4 WoodZACpurlinsspacedOPTIONALMin.26 ga,GUIfPBR screws spliced 24 in.c.c.into mod purlinsPBR-W-2 24 in.o.c. Ap,n,°ovedfire barrier As required per FBC 1110.538.inc:h coverage Laps"asteried with 1/4-14 x 7/8 ZAC know Lap screwsoverOrInsulation
Min. 15/32 spaced 24 i":.O.C.
B-C plywood _ ,.,
Min. 1x4 No.2
SYP wood GrrIIPEJR Type 2 attachment with kih 15 15 HWHpurlinsspacedOPTIONALMin.26 ga,GUIfPBR WoodZAG screws spaced 12 in.o.c,lute wood purlinsPESR-11%/ 12 in.o.c. Ap,G,wetl fire barrier 4:.required per FBC 38-inch coverage Laps fastened With 1/4-14 x 718" HWM ZAC Impax Lap -1'i1'7a
over car Insulation screws spaced 24 in,o.c.Min. 15/32
B-C plywood
OPTIONAL GuifPI3R Type 2attachment with 49-115 HWF4WoodZAC
PEIR-VV•41
Min. 15/32 Appt>"oved fire barrier As required per FBC Niin.26 tJa,GUIfPBR s«news spaced 12 in.o.c. 154.75B-C plywood
r Insulation 36-inch coverage Laps fastened with 1/4-14 x 7/8" HWM ZAC Impax Lap
sirews spaced 24 in.o.c.
1.1 11.•...,-
w r
Approved Systems for GulfRib over Wood Deck(New or IEicietirtg)
y: tern Deck F::re eprrier/ Unclorlaylnent Roof Panel Panel Attachment MOPNo. inBUlgtion PO
Min. 15/32 OPTIONAL Min.29 ga,GulfRib GuifRib Type 1 attachment with#with 00,15 HWHRIE-W-1 B-C plywood
Approved fire barrier 4s required per FBC 3E;..inc h coverage hloodnAC screws spaced 24 in.b;c 7'I, 9
car insulation
Min. 1x4 No.2 _._.,.,. —
x....- µms .-
SYP wood
purlins spaced OPTIONAL Min.26ga,C3ulfRib GulfRib Nuhn: 1 Attachment with d9-1 E HWH WoodZACRIE•W 24 in.o.c. Ape.raved fire barrier As required per FBC 3E;-inch coverage screws spaced 24 in.o.c:.into Wood purlins 106.75
over or Insulation
Min. 15/32
B-C plywood
GCS2f002. 'b F1_3=i£316-122 Fuge 3 of 4
This evaluation report is provided 'or SI:cde of Florida product approval under Rule 61G20.3. The manufacturer shall notify CREEK Technical Services,LLC of any product:charoaa or
quality assurance changes throughout the duration for which this report Is valid. This avaluatiun report does not express nor Imply warranty, installation, recommended tee, or other
product:at:r hutes that are not specifically addressed herein.
r. GULF COAST SUPPLY&MANUFACTURING,LLCC"' REE Metal Roollnd(M)J HZ)
TIE CHNICAL SERVICEi, LLCAPP'IVI I ;B
M
kms_
Approved Systems for GulfRib,)vier Wood Deck(Nero or +i ing)
mo.,-...—..--.—.,..........-w..„,.,....
System Fre Barrier/MOPDeckUnderlaymentIRncbfPanelPanelAttachmentNo. IneUlgtion 1:1!;')
w...-iYLi, r•• ....., r...i...,y w„Mmlf~x./ r......,.n....irrr. m.mv....M.MOr
OPTIONAL
B .15y5//3322 hAin.26 0a,GulfRib GutfAib Tyve2 attachment with#9-111 HWH WoodZACF:IB-W-3 App,-oved fire barrier As required per FBC
3f;-inch coverage screws spaced 12 in,o.r,. 156.25
Or int illation
w.—Min.1x4 No.2 -_.,.
w......,— r,r......._M..m..-. M,....r
SYP wood
purlins spaced t)PTIONAL Min.20 ga,GulfRib GU/fRib Tyne 1 Attachment with 1t9-1R HWH WoodZACRIE-W-4 12 in.o.c. App.uvea tire barrier As required{:ter FBC 164.2536-Inch Coverage screws spaced 12 in.o.c:.into wood puffinsoverorInsulation
Min.15/32
B-C plywood
M w..wdmiNuiYY--M w..W,.YV- –,, M,. .•.
GCS2170Q2, :b FL3 X81 B.R2 Page 4 of 4
This evaluation report is provided'tor State of Florida product.approval under Rule 61G20.3. The manufacturer shall notify CREEK Technical:Services,LLC of any product changes or
quality assurance changes throughout the duration for which this report Is valid. This evaluation report does not express nor Imply warranty, Installation, recom mended me,or other
produce:attributes that are not specifically addressed herein.
R EEK GULF COAST:3Ur'FLY&MANUFACTURING,LLC
Metal Rooting gFHlIMZ)
OHNICAL SER /I:;r:h L.LC
APPENDIX C
DESIGN WIND 4OAD5
The following tables provide design wind loads for components and cladding in accordance with Section 1620 of the FBC and ASCE 1-16 under the follss,voind
provisions:
1. Wind speeds for risk ::at ry I, II, Ill, and IV buildings shall be as defined in Section 1620 of th_:FE3C.
2. Ex:posuire C and D shall tie as gefined in section 1820 of the FBC.
3. [Design wind load provided only for gable/hip rpofs with roof slopes be=tween 2: 12 and 6.1:12
4. All caldulations are based on Ha effective wind area of 10-ft2 or less.
5. Topographic factors such as escarpments or hills have peen excluded from the analysis
6. Caverhdngs have been elude from the anal'y'sis.
7. Wind directionality factor, Kd 0.85
8. Design wind loads are calculated using Pasd 0.6Puit.
9. Zone 2 is inclusive of Zone 2e,Zone 2n,and Zone 2r
10. Zone 3 is inclusive of Zone 3e and Zone 3r
11. Projects with mean roof heights greater than€0-ft shall De evaluated lbS'a licensyd design prclessiohal
12. Zones 1,2. and 3 shall be defined as shown below, Dimension"a"shall bit 10%of the least horizontal dimension or(C`.l ': Kean Roof Height),whichever
IM smaller, but not les_ then either 4%of the least horizontal dimension or,aft
Gable Hip
3 2 ;3— 2 momover
3 2 3 a
V
2 1 i 2 1 :t 2 1 2 ,i 2
3 2 4 3 2 3 2, l21 a
I
w.
I a I 13 I a I
M
I a I
GCS2000: . .b FI.3 81EI.R2 P,:ge 1 of 3
This evaluation report is provided `or Stade of Florida product Approval under Rule 61G20-3. 'The manufacturer shall notify CREEK Technical: ervicea,LLC of any product char°ges or
quality assurance changes throughout the duration for which this re,port Is valid. This evaluation report does not express nor Imply warranty,installation, recommended roe, or other
product atrbutes that are not specifically addressed herein.
I , GULF COAST SU„'SLY&MANUFACTURING,4-LCcx 1i Metal Roolinq(HVIHZ)
TF HNICAL SER/I-:I: L.l.0
APP'h14001' C
L.i Roofs in Eixsurrr CIn Mlami-Dade Zi Elr'rnarau0unty(Roof sl:E9s bc!!ween 2:12 and 12:121
Basic rind:<oeed(mph)Mean Roof .. r......
Buil ding"ype Zona FzsnC t I Flit Icd,tut I Risk Cai II Risk Cat II Rifk" t I IV Risk.C st III IVHeight(ft) .._.»
156-,..
fa--- --
165 170 ....,. 175 --.,.. ; 0
20 _'_.„^., 4311-
w,
s__74.0,_.... -78.5 33,0 8EL6 _
25 _ _ -85,1 72,8 77.3
r_ ~
81.9 - -86677 92.6
1 30 _ 67.4 J'y_'_8"a 80_6___. _ -89,.4 .__, ~904_ gE{.5_
40 _72,01 . 60.6 85.6 90.7 9¢_f150102,
4n
4.8.~-89 7 -'-_95.0 100.5
7F1129,,(
1,--
2;
71::
65..
4-
3-
1i
107.3-75.$ . s
60 ,.....„..-78.'1 87k1- 93.0 98.5 .....,..-1 1'1.3
20 90, 101.7 108.0 114.4 1 1.1 "•. 129
25 95.(1 106,3, _ 112.8 -119.6
s-
1x5 135.00.
Enclosed/ 2 30 99,t1 110.8 117.6 124.6 138 140,8
Partially Open 40
a.:-
10 .1 117.4 124.8 13 .2
13.1,9
1 49:4
r
50 ___. .. 1 . 123.2 130.8__ 138.E _ :1410 156,88_
i...... 60 x'14. 1277.x. .r 135.6,.......'-143.7 10,42.,0 1 Ei2.3
20 08.1 120.!3 _ 128.4 136.0 143.9 153.
25 12 9 12f3.3 _ -134.1. 142.1 160.3 160,5.-.-
3 30 __---_,....
r-i -7 131.7._ 139.8 ______-148.1 _.'7 167_33-
40 _ *...-114,9 139.
7tt -
148.3 157.7 1t3 177.6
T_
146.k5 15 .5 '-184.7 x•174.3 186.150530308
60 35._7 151,
8K -
161.2 170.82010.7 1p2,9
M8'______86.6'_.........._.
r -
91.8 9 1 T103
25
Y__y... -
781 85.2_ - 90.4 _ 95.8 101.4 108.3
1 30 g,...-79,4 88.k 94.3 _ -
g '
99.9 •1Q5> 1'2.8
40 84„1 94,'_ .100.1" 106.0 __-112.2 1 8988
50 T-_•,..-88,:t 9e.gi
ti
104.9__»
M -
111.1 117.6_• X1;:5.5..._
60
y....-
91 102 11~ -108.T _•,._ _115.2121 9i30.2-
20 T- 0 ., LL'113 120.6 _..
r -
127.8 1862 144. ..
1 - 25
r - -106.0 118.8 125.9_ 133.4 141.2 TO_7•
Partially 30 ____;110.5 123.7" 131.3 139.1 i47.2 1,171
Encloee:d 40 117•x 131.2_ -139.3 ..
4. -147.6 ,. "1 8.2 108.8_
50 123.0 137.5 146.0 _-154.7 w 103 7 11-74.8.,
l.... . 60 127.7 1428
x, -151.4 ____:
115469:03.
160.4 1 .7 181 2
72018 13 .8 140.9 1 0 1Ei M
25
s. _ 24.0 I38.'r"147.
2x
186.0 176.2
3 30 29.F 144.Ei 153.5 , -162.8 172.0 183.7
40
y...'3.1 15,4 162.9_ 172.6 _ -102._6 195.0_
50 143.7 1804_
y_ -
170.7' _ -180.9 191.4 2t1g4..3.-
60 ._._.... 149.0 168.7_ ___
4 -
177.0• 187.5 19_8_,4 2 1.9.
GCS20002,:eib FL33818-R2 013ge a of 3
This evaluation report is provided'sr Stet*Of Florida product.approval under Rule 61020.3. The manufacturer shall notify QREEK Technical,3Ervlces,LLC of any product;changes or
quality assurance changes throughout the duration for which this report Is valid. This evaluation report does not express nor Imply warranty,Installation,recommended utie,or other
product attributes that are not specifically addressed herein.
cREEK:GULF COAST:SUPPLY&MANIJFACTt1RINC,LIG
Motel Root'nu(h1VH2)
rimoo
Ti::cHNICAL SERVII:ES. LL C
APPENDIX C
yab e!, ip Roofs in E:r r -"nhlllarrl-Daden Ill wa.r
w..,,, .....,
M....+ 4..•.rri.. 44. ..
m d ro dy0unty(Roof sla ms hraiweer+2 12 and 12:121
Mean Roof Basic Wind`oeed tmph,
Err ding 1'ype Zone
Height(ft) ,..•..r
2t l Rid It d;ttt j-"T_ k C til , -Rit la -at II,IV Risk Cat=
WOW
III IVfkCRiskCciIsa
156 IE,.. 1754.....440.40,.....41...
5 170 160 1 El6
20 74. v !
3 0._88.8........=94.1 _ ...... 9®- 1063...,,
25 77.0 EIC,.B_ 92.1 __97,8 0, 30 3._.-
1 30 _ __..- -1-1•1--- 4 69i"!_ 95.4 _.. -101.1 147.0 1 4 2
40 84.9 011,-- -100.4 106.3 112.5 1 ,0,
11-
5660 _ 88,(t 98, 104.5' 110.1 117,1 1 551
1.41.1N.1164....: 60 ,_.. -90.i
f-
101 107.8 _ ___-114.10 8 1;!8,0
20 _ _ 09.1
x,
122.1 129.6, .
x,......,_..+_
137.4 1-i , 1f5
25 113.2 _ 128.3, -134.4 142.4 _,__.,Y150.7 1f1009
iE nclosecli 2 30 117.2 131"1. 139.2__..• -147`9 _-__ _,=.':158.0 168.6~-
Pair;ally Open 49 123.5 137, -146.4 _.._ -155.1 164.1! 1 5,22 Y
50 128.5 _ • _143"31 -152.4,._ 161. ._.._._._
m.r.
Y'170.8 18224"'
r.,.,,......, 60
r..,
X32.4 1 1 157.2 .,...
A..-
166.f3 ......-176.2 fs8,2
2t 21 IaCi.1 154.0 163.2_ ....,..
1--
172.7 18 ,4
2 13x.5 160.
bx- -
159.7. . ,. _169.4 .__ .-179.1 181,2..
3 3Q 4L_ . ;
9 1559 165.4 am,.'155.0 16111
49 - _.......:146.5 ..183,'3 174.0 _11-____-----118754:: 195,1 U8,3-_
50 152.5 170.4 192.0a .. 181.1 2:43.1 2.6,$
r.......w -- 60 57. 178.0186.8
29__3.1__
198.b 209.5 X223,7
r....•.i w
w..•.....29 __. 7,9 97,!103.J' 114.1 ma.-
1116.5 124. 4
25 - _ g0,i 101.5 _ 107.8 114. 120,8 P^AgT0 _
30 94.01 -105.1 111.6'__.. _11$.5 125.1 1;13,61
40 - _.y.. .98,0 110.8 117_4 124.c4 131.6 1 10,5
50 02.9 115.1~ 122.2 129.5 137.0 11863
T~
6o 06.1 118.7 126.0 133.6 141.3 150.
9w
w...
20 _ ,,...,.
r..2+-13311.3 144.7 .,.,..*....+-153.3 ......,.-162.2•s-2 3..
25 _____-_20 141.3.._. 150.0-__. .
r-
159,,1 __.::,1 6 2 _ .:1;%9966
Partially 2 34 130• _148.4 155.4_ 164.7 174,2 1fS80'
Enclosed 40 137.6_-154.0 163 4 __.
y._ -
173.7 183• .2 1s5 6
50 143.3 180.;3 170.1 __~-180.3 190.7 203,6._._
166,3 ..
rte- -175.5 - .. ____186.0 ..,.....196.7 2"0,1s.. 127.
20 , ...,,... 15913 169.1'.,•....
d.,...-179.Z 189.
25 147'7 185,2 175.4
M
185.8 196.6 2"0,0
30 153.0 . 171.1 161.6 192.5 i: 3.63
40 _ _ -160.9 180.0 191.0 202.4 214.2,__ -228,7
50 y_ -167.5 187,3~ 198._9 210,7 223.0 g 1 _
60 172.7 193.2~ -205.1 .
s _ -
217.4 X130.0 245,6
J
w.•••.r...r.. t.ma,..,.,./ ..• w.•.rrwr..,emon+ rw ---...ti we.....,. n"•w.r+ , nrr.en
GCS20002.2t) F1,33819.4R2 Page?of 3
This,evaluation report is provided for State of Florida product approval wider Rule 61020-3. The manufacturer shall notify GREEK Technical services,LLC of any product changesro
quality assurance changes throughout the duration for which this report Is valid. This evaluation report dyes not express nor imply warranty,installation, recommended use,or other
product attributes that are not specifically addressed herein.
NOTICE OF COMMENCEMENT
State of FL Tax Folio No. 169692-0100
County of Duval
To Whom It May Concern:
The undersigned hereby informs you that improvements will be made to certain real property, and in accordance with Section 713
of the Florida Statutes,the following information is stated in this NOTICE OF COMMENCEMENT.
Legal Description of property being improved: 15-57 09-2S-29EN ATLANTIC BEACH UNIT NO 2 PTLOT 54
Address of property being improved: 1937 BEACH AVEAtlantic Beach FL 32233
General description of improvements: Metal Re Roof
Owner: Elliot Zisser Address: 1937 Beach Ave Atlantic Beach, FL 32233
Owner's interest in site of the improvement:
Fee Simple Titleholder(if other than owner):
Name:
Contractor: Ford Roofing Systems Inc.
Address: 3839 Millpoint Dr Jacksonville, FL 32257
Telephone No.: (904)314-7671 Fax No:
Surety(if any)
Address: Amount of Bond $
Telephone No: Fax No:
Name and address of any person making a loan for the construction of the improvements
Name:
Address:
Phone No: Fax No:
Name of person within the State of Florida,other than himself, designated by owner upon whom notices or other documents may
be served: Name:
Address:
Telephone No: Fax No:
In addition to himself, owner designates the following person to receive a copy of the Lienor's Notice as provided in Section
713.06(2) (b), Florida Statues. (Fill in at Owner's option)
Name:
Address:
Telephone No: Fax No:
Expiration date of Notice of Commencement (the expiration date is one (1)year from the date of recording unless a different date is
specified): 07/30/2022
THIS SPACE FOR RECORDER'S USE ONLY OWNER
Doc f? 022130100,nP BK'n"oz oage 1718, 5//7/a 2
Number Pages:1
V v
Signed: Date:
Recorded 05/23/2022 11:41 AM, Before me this /7 day of /'r in the Coffin_Uo DYg.L$ t
p JJODYPHILLIPSCLERKCIRCUITCOURTDUVALOfFlorida,has personally appea -• • -ger-.e?
COUNTY y
Notary Public at Lar:- e of Flor - n Ta :
RECORDING $10.
00r
LL
My commissio pir- • mission" 12979
Personally Kni-•• oFF'• My omm. xpi
r
Produced I:- i ication:
2021 -2022 LOCAL ..iUSINIESSS TAX RECEIPT
JIM OVERTON, DUVAL COUNTY TAX COLLECTOR
231 E.Forsyth Street,Suite 130,Jacksonville,FL 32202-3370
Phone:(904)255-5700,option 3 Fax:(904) 255-8403
h ttp s://taxcoltector.coj.net/
Note -A penalty is imposed for failure to keep this receipt exhibited conspicuously at your place of business. This
business tax receipt is furnished pursuant to Municipal Ordinance Code,Chapters 770- 772,for the period
October 01, 2021 through September 30,2022.
MAUST, ROBERT JOHNSON
3839 MILLPOINT DRIVE
JACKSONVILLE, FL 32257
ACCOUNT NUMBER: 220439
BUSINESS NAME: MAUST, ROBERT JOHNSON
PHYSICAL ADDRESS: 3839 MILLPOINT DRIVE
JACKSONVILLE. FL 32257
CLASSIFICATION CODE: 5 QUALIFYING AGENT,CONTRACTORS
COUNTY TAX: 0.00
MUNICIPAL TAX: 100.00
COUNTY LATE PENALTY: 0.00
STATE LICENSE NO: CCC1327698
MUNICIPAL LATE PENALTY: 25.00
TOTAL TAX: 125.00
RENEWAL
VALID UNTIL September 30, 2022
ATTENTION***
THIS RECEIPT IS FOR BUSINESS TAX RECEIPT ONLY.
CERTAIN BUSINESSES MAY REQUIRE ADDITIONAL STATE LICENSING.
This is a business tax receipt only. It does not permit the receipt holder to violate any existing regulatory or zoning laws of
the County or City. It does not exempt the receipt holder from any other license or permit required by law. This is not a
certification of the receipt holder's qualifications.
JIM OVERTON,TAX COLLECTOR
THIS BECOMES A RECEIPT AFTER VALIDATION.
Paid INT-23-00011904 01/05/2022 $ 125.00
Revision Request/Correction to Comments **ALL INFORMATION
HIGHLIGHTED IN
GRAY IS REQUIRED. City of Atlantic Beach Building Department
800 Seminole Rd, Atlantic Beach, FL 32233
Phone: (904) 247-5826 Email: Building-Dept@coab.us PERMIT #: _____________________
Revision to Issued Permit OR Corrections to Comments Date: ________________
Project Address: ____________________________________________________________________________________
Contractor/Contact Name: ____________________________________________________________________________
Contact Phone: ______________________________ Email: _________________________________________________
Description of Proposed Revision / Corrections:
__________________________________________________________________________________________________
__________________________________________________________________________________________________
__________________________________________________________________________________________________
__________________________________________________________________________________________________
I_______________________________ affirm the revision/correction to comments is inclusive of the proposed changes.
(printed name)
Will proposed revision/corrections add additional square footage to original submittal?
No Yes (additional s.f. to be added: _____________________________)
Will proposed revision/corrections add additional increase in building value to original submittal?
No *Yes (additional increase in building value: $____________________) (Contractor must sign if increase in valuation)
*Signature of Contractor/Agent: _______________________________________________________
__________________________________________________________________________________________________
(Office Use Only)
Approved Denied Not Applicable to Department Permit Fee Due $_______________
Revision/Plan Review Comments_______________________________________________________________________
__________________________________________________________________________________________________
Department Review Required:
Building _____________________________________________
Planning & Zoning Reviewed By
Tree Administrator
Public Works
Public Utilities _____________________________________________
Public Safety Date
Fire Services Updated 10/17/18
ROOF22-0031
06/08/2022
1937 Beach Ave
fordroofing@gmail.com
Changes have been made to product approval sheet as needed. Also as requested it is a gable roof that has a pitch of
12/12.
Robert Maust
4
4
4
9043147671
By Toni Gindlesperger at 2:30 pm, Jun 09, 2022
By Mike Jones at 7:43 am, Jun 17, 2022
50.00X