460 STURDIVANT ROW22-0021 COAB Permit Form with ConditionsOWNER:ADDRESS:CITY:STATE:ZIP:
BROWN BROTHERS
CAPITAL LLC 1016 LASALLE ST JACKSONVILLE FL 32207
COMPANY:ADDRESS:CITY:STATE:ZIP:
TECO Peoples Gas 4040 Phillips Highway Jacksonville FL 32207
TYPE OF
CONSTRUCTION:
REAL ESTATE
NUMBER:ZONING:BUILDING USE
GROUP:SUBDIVISION:
170698 0000 SALTAIR SEC 03
JOB ADDRESS:PERMIT TYPE:DESCRIPTION: VALUE OF WORK:
460 STURDIVANT AVE RIGHT OF WAY COMMERCIAL
RIGHT OF WAY GAS SERVICE LINE $0.00
LIST OF CONDITIONS
Roll off container company must be on City approved list . Container cannot be placed on City right-of-way.
1 PUBLIC WORKS EROSION CONTROL INSTALLATION INFORMATIONAL
Notes:
Full erosion control measures must be installed and approved prior to beginning any earth disturbing activities. Contact the Inspection Line (904-247-
5814) to request an Erosion and Sediment Control Inspection prior to start of construction.
2 PUBLIC WORKS ON SITE RUNOFF INFORMATIONAL
Notes:
All runoff must remain on-site during construction.
NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property
that may be found in the public records of this county, and there may be additional permits required from other
governmental entities such as water management districts, state agencies, or federal agencies.
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN
YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT
MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU
INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE
RECORDING YOUR NOTICE OF COMMENCEMENT.
MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION.
ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING
CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES .
ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY.
1 of 2Issued Date: 6/30/2022
PERMIT NUMBER
ROW22-0021
ISSUED: 6/30/2022
EXPIRES: 9/28/2022
RIGHT OF WAY PERMIT
CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
ATLANTIC BEACH, FL 32233
FEES
DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT
TOTAL:
3 PUBLIC WORKS ROLL OFF CONTAINER INFORMATIONAL
Notes:
Roll off container company must be on City approved list. Approved list can be obtained at the Building Department at City Hall. Roll off container
cannot be placed on City right-of-way.
4 PUBLIC WORKS RIGHT OF WAY RESTORATION INFORMATIONAL
Notes:
Full right-of-way restoration, including sod, is required.
5 PUBLIC WORKS UTILITY ROAD CUT INFORMATIONAL
Notes:
Any utility cuts in the road must be repaired using COJ Standard Detail Case X and must be overlaid 10 feet in each direction from the center of the cut.
Repair must be shown on the plans.\r\r\r\r\r\r
6 PUBLIC WORKS RUNOFF INFORMATIONAL
Notes:
All runoff must remain on-site. Cannot raise lot elevation.
7 PUBLIC WORKS CIRCULAR DRIVEWAY INFORMATIONAL
Notes:
Maximum circular driveway width within the City right-of-way is 12 feet.
8 PUBLIC WORKS REVISION INFORMATIONAL
Notes:
Any plan change must be submitted as a Revision to the Building Department.
9 PUBLIC WORKS INFRASTRUCTURE INFORMATIONAL
Notes:
Any damage done to infrastructure must be repaired by Contractor.
10 PUBLIC WORKS AS-BUILT INFORMATIONAL
Notes:
Contractor must submit As-Built plans to City within 30 days after completion of project.
11 PUBLIC WORKS OTHER PUBLIC WORKS CONDITION INFORMATIONAL
Notes:
All construction debris must be removed from job site by Contractor.
12 PUBLIC UTILITIES UNDERGROUND WATER SEWER UTILITIES INFORMATIONAL
Notes:
Avoid damage to underground water and sewer utilities. Verify vertical and horizontal location of utilities. Hand dig if necessary. If field coordination is
needed, call 247-5878. Any digging requires calling 811 to have ALL public utilities located.
2 of 2Issued Date: 6/30/2022
PERMIT NUMBER
ROW22-0021
ISSUED: 6/30/2022
EXPIRES: 9/28/2022
RIGHT OF WAY PERMIT
CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
ATLANTIC BEACH, FL 32233
ROW22-0021
9/23/20212:40:48 PMREVISIONDESCRIPTION:
REVISION
LAST
ofSTANDARD PLANS
FY 2022-23 SHEETINDEX
ROAD WORK
END PRESENT
WHEN WORKERS
DOUBLED
SPEEDING FINES
AHEAD
WORK
ROAD
CLOSED
SHOULDER
RIGHT
ROAD WORK
END
PRESENT
WHEN WORKERS
DOUBLED
SPEEDING FINES
AHEAD
WORK
ROAD
ROAD WORK
END AHEAD
WORK
ROAD
ROAD WORK
END
AHEAD
WORK
ROAD
CLOSED
SHOULDER
RIGHT
102-602 1 211/01/21
TWO-LANE AND MULTILANE, WORK ON SHOULDER
6" White (See Note 7)
BL/3
L/3
NOTE:
of the "Shoulder Closed" sign (W21-5a).
"Worker" sign (W21-1) may be used instead
9. When there is no paved shoulder, the
distances for work on the median.
with associated work zone sign spacing
8. Omit "Shoulder Closed" signs (W21-5a) along
place for 3 days or less.
omitted when the work operation is in
7. Temporary pavement markings may be
hours or less.
work operation is in place for 24
distances may be omitted when the
associated work zone sign spacing
Work” Signs (G20-2) along with the
Present” signs (MOT-13-06) and “End Road
6. The “Speeding Fines Doubled When Workers
use a lane closure.
and work zone speed is greater than 45 MPH,
5. For work less than 2' from the traveled way
egress.
to accommodate work vehicle ingress and
work area), use a flagger or lane closure
(excluding establishing and terminating the
through traffic lanes in a one hour period
4. When four or more work vehicles enter the
or less.
devices for work operations 60 minutes
Engineer may omit signs and channelizing
15' from the edge of traveled way, the
3. Where work activities are between 2' and
channelizing device spacing values.
See Index 102-600 for “L”, “X”, "B", and
B = Buffer Length
X = Work Zone Sign Spacing
2. L = Taper Length
shoulder.
of divided roadways, with work on the
and Multilane Roadways, including Medians
1. This Index applies to Two-Lane, Two-Way
XXX
10' Min.
X
X
X
XXX
SYMBOLS:
Work Zone Sign
Work Area
Channelizing Device (See Index 102-600)
Lane Identification and Direction of Traffic
W21-5a
W20-1F
W20-1F
W21-5a
W20-1F (See Note 6)
MOT-13-06 (See Note 6)
G20-2
WITH WORK ZONE SPEED OF 45 MPH OR LESS
SHOULDER WORK LESS THAN 2' FROM THE TRAVELED WAY
TWO-LANE ROADWAY
(See Note 6)
G20-2
(See Note 6)
MOT-13-06
SHOULDER WORK BETWEEN 2' AND 15' FROM THE TRAVELED WAY
TWO-LANE ROADWAY
(See Note 6)
G20-2
(See Note 6)
G20-2
W20-1F
9/23/20212:40:49 PMREVISIONDESCRIPTION:
REVISION
LAST
ofSTANDARD PLANS
FY 2022-23 SHEETINDEX
CLOSED
SHOULDER
RIGHT
PRESENT
WHEN WORKERS
DOUBLED
SPEEDING FINES
AHEAD
WORK
ROAD
ROAD WORK
END
CLOSED
SHOULDER
RIGHT
AHEAD
WORK
ROAD
ROAD WORK
END
102-602 2 211/01/20
TWO-LANE AND MULTILANE, WORK ON SHOULDER
6" White (See Note 7)
Median
Median
BL/3
L/3
10' Min.
X XX X
XX X
SYMBOLS:
Work Zone Sign
Work Area
Channelizing Device (See Index 102-600)
Lane Identification and Direction of Traffic
(See Note 8)
W21-5a
(See Note 8)
W21-5a
WITH WORK ZONE SPEED OF 45 MPH OR LESS
SHOULDER WORK LESS THAN 2' FROM THE TRAVELED WAY
MULTILANE ROADWAY
SHOULDER WORK BETWEEN 2' AND 15' FROM THE TRAVELED WAY
MULTILANE ROADWAY
W20-1F (See Note 6)
MOT-13-06 (See Note 6)
G20-2
W20-1F (See Note 6)
G20-2
9/21/202112:26:54 PMREVISIONDESCRIPTION:
REVISION
LAST
ofSTANDARD PLANS
FY 2022-23 SHEETINDEX
DETOUR DETOUR
DETOUR
DETOUR DETOUR
DETOUR
R9-11AL
PEDESTRIAN DETOUR
(See Note 4)
R9-10
(See Notes 4 and 5)
Advance Closure LCD
(See Notes 4 and 5)
Advance Closure LCD
AHEAD
WORK
ROAD
W20-1F
AHEAD
WORK
ROAD
CROSS HERE
AHEAD
SIDEWALK CLOSED
CROSS HERE
AHEAD
SIDEWALK CLOSED
CLOSED
SIDEWALK
USE OTHER SIDE
SIDEWALK CLOSED
USE OTHER SIDE
SIDEWALK CLOSED
102-660 1 211/01/20
SIDEWALK CLOSURE
SYMBOLS:
Work Area
NOTES:
facilities (e,g,, transit stops, residences, or business entrances).
5. Omit the Advance Closure LCD if it blocks access to other pedestrian
in accordance with the manufacturer's instructions.
4. "Sidewalk Closed" signs (R9-XX) may be mounted on pedestrian LCDs
panel to the surface of the sidewalk.
maintain a minimum 7’ clearance from the bottom of the sign
3. For post mounted signs located near or adjacent to a sidewalk,
2. Place pedestrian LCDs across the full width of the closed sidewalk.
closed crosswalks.
1. Cover or deactivate pedestrian traffic signal display(s) controlling
Work Zone Sign
Lane Identification and Direction of Traffic
Pedestrian Longitudinal Channelizing Device (LCD)
M4-9BR
M4-9BL
M4-9BL
M4-9BR
R9-11AR
M4-9BL
M4-9BR
(See Note 4)
R9-10
(See Note 4)
R9-9
W20-1F
9/21/202112:26:55 PMREVISIONDESCRIPTION:
REVISION
LAST
ofSTANDARD PLANS
FY 2022-23 SHEETINDEX
C C
C C
Existing Sidewalk
Existing Sidewalk
Temporary Barrier
6" White
W20-1F
AHEAD
WORK
ROAD
W20-1F
AHEAD
WORK
ROAD
W20-5
AHEAD
CLOSED
RIGHT LANE
Note 4)
(See General
MOT-13-06
PRESENT
WHEN WORKERS
DOUBLED
SPEEDING FINES
W4-2
ROAD WORK
END
(See Note 4)
G20-2
Existing Sidewalk
6" White
W20-1F
AHEAD
WORK
ROAD
W20-5
AHEAD
CLOSED
RIGHT LANE
Note 4)
(See General
MOT-13-06
PRESENT
WHEN WORKERS
DOUBLED
SPEEDING FINES
W4-2
ROAD WORK
END
(See Note 4)
G20-2Min.2'-0"102-660 2 211/01/21
SIDEWALK CLOSURE
PEDESTRIAN SPECIAL DETOUR
(Temporary Barrier Shown, Low Profile Barrier Similar)
PEDESTRIAN DIVERSION - OPTION 1
(Work Zone Speed 35 mph or Less)
PEDESTRIAN DIVERSION - OPTION 2
100'
100'
B XLXXXX
X
B XLXXXX
SYMBOLS:
NOTES:
Temporary Pedestrian Way
Work Area
Pedestrian Longitudinal Channelizing Device (LCD)
Work Zone Sign
Channelizing Device (See Index 102-600)
Lane Identification and Direction of Traffic
Arrow Board
Crash Cushion
Plans or as approved by an Engineer.
5. Pedestrian Diversion Option 2 may only be used when called for in the
hours or less.
distances, may be omitted when the work operation will be in place for 24
and "End Road Work" signs (G20-2), along with associated work zone sign
4. The "Speeding Fines Doubled When Workers Present" signs (MOT-13-06)
for curb ramps diverting pedestrian traffic into a closed lane.
requirements of Index 522-002. Detectable warnings are not required
3. When temporary pedestrian ways require curb ramps, meet the
5' in width at intervals not to exceed 200'.
Provide a 5' x 5' passing space for temporary pedestrian ways less than
of 0.02, except where space restrictions warrant a minimum width of 4'.
2. Provide a 5' wide temporary pedestrian way with a maximum cross-slope
See Index 102-600 for "L", "B", "X", channelizing device spacing values.
X = Work Zone Sign Distance
B = Buffer Length
1. L = Taper Length
Merge
Arrow Board Mode:
Merge
Arrow Board Mode:
ROW22-0021
ROW22-0021