Loading...
760 REDFIN ACC22-0022 Building Plans 1 of 2DRAWN BY:CHECKED BY:JOB #:SHEETDUFFIE RESIDENCE 760 REDFIN DR. ATLANTIC BACH, FL 32233TLDATE:TLTLE-DUFFIE4/18/22REVISIONS DATE SHEET TITLE:PROJECT:11x17 TRUNG T. LE, P.E.Florida License #77614# TEL: (321) 313-2502 1575 Bream St. Merritt Island, FL. 32952 CA# 33103 TLE Engineering, PLLCThis item has been digitally signed and sealed by Trung T. Le, PEon the date shown on the timestamp using a Digital Signature.Printed copies of this document are not considered signed andsealed and the signature must be verified on any electronic copies.COVERSHEETWORK AREA COMPLIANCE METHODCLASSIFICATION: ADDITIONSCOPE OF WORK (ADDITION)ADDITIONACCESSORY STRUCTURE (GUEST HOUSE)PRODUCT APPROVALS SHALL BE SUBMITTED SEPARATELY BY GENERAL CONTRACTORDRAWING INDEXCCOVER SHEETPPSITE PLAN01FLOOR PLAN & ELECTRICAL LAYOUT02ELEVATIONSSN STRUCTURAL NOTESS1FOUNDATION & FRAMING PLANSD1DETAILSD2DETAILSCODE INFORMATIONCNORTHBUILDING CODESBUILDING: 2020 FLORIDA BUILDING CODE, 7th EDITION - RESIDENTIAL2020 FLORIDA BUILDING CODE, 7th EDITION - ENERGY CONSERVATION 2020 FLORIDA BUILDING CODE, 7th EDITION - EXISTINGHVAC:2020 FLORIDA BUILDING CODE, 7th EDITION - MECHANICALELECTRICAL: 2017 NATIONAL ELECTRICAL CODE (NEC) - NFPA 70PLUMBING: 2020 FLORIDA BUILDING CODE, 7th EDITION - PLUMBINGPROPOSEDLOCATION OFGUEST HOUSECODE COMPLIANCE:OCCUPANCY TYPE:RESIDENTIAL (GROUP R-3)CONSTRUCTION TYPE:V-B (UNPROTECTED) NOT SPRINKLEREDNUMBER OF STORIES:1-STORYDESIGN CRITERIA130 MPH WIND SPEEDRISK CATEGORY IIEXPOSURE B **REFER TO STRUCTURAL NOTES FOR ADDITIONAL DESIGN INFORMATION**GUEST HOUSE ADDITIONDUFFIE RESIDENCE 760 REDFIN DR.ATLANTIC BEACH, FL 32233AERIAL VIEWABBREVIATIONSA.B. Abv. A/C Adj.AFFAHUBFBm.Bot. BPBrg. Cir.Clg.Anchor BoltAboveAir-ConditionerAdjustableAbove Finished FloorAir Handler UnitBifold DoorBeamBottomBypass doorBearingCircleCeilingBFFBelow Finished FloorApprox.Approximate Bldg.BuildingAlum.Aluminum Cant.Cantilever Col.Conc. DDeco.Ded.Dbl.Dia.Disp.Dist.DVDWEa.EWElec.Elev.ColumnConcreteDryerDecorativeDedicated OutletDoubleDiameterDisposalDistanceDryer VentDishwasherEachEach WayElectricalElevationDLDead LoadDtl.DetailCont.ContinuousConn.ConnectionFBCRFFFGFlr.Fnd.Flr. Sys.FPFt.Ftg.Galv.GCGFIHBFlorida Bldg. Code-Resid.Finished FloorFixed GlassFloorFoundationFloor SystemFireplaceFoot / FeetFootingGalvanizedGeneral ContractorGround Fault InterrupterHose BibbFVField VerifyHCHalf CircleHdr.Hgt.Int.KSLav.LF LTMax.Manuf.Micro.Min.MLMir.MonoHeaderHeightInteriorKnee SpaceLavatoryLinear Ft.Laundry TubMaximumManufacturerMicrowaveMinimumMicrolamMirrorMonolithicHRHorizontal Roller Hor.HorizontalLLLive LoadN.T.S.Not to ScaleO.C.Opt.Ped.PLPLFPSFPTPrefab.Ref.Req'd.Rm.RndR & ShSDOn CenterOptionalPedestalParallamPounds per linear footPounds per square footPressure TreatedPrefabricatedRefrigeratorRequiredRoomRoundRod and ShelfSmoke DetectorOSBOriented Strand BoardPlt.PlateReinf.ReinforcementSh. Sht.SLSPFSq.SPTemp.Thk.TBDT.O.M.Trans.Typ.UCLU.N.O.Vert.VL ShelvesSheetSide LightsSpruce Pine FirSquareSouthern PineTemperedThickTo Be DeterminedTop of MasonryTransom WindowTypicalUnder Cabinet LightingUnless Noted OtherwiseVerticalVersalamSHSingle HungT.O.W.Top of WallEmbed.EmbedmentExt.Exp.ExteriorExpansionFBCBFlorida Bldg. Code-Building Epx.EpoxyEOREngineer on RecordVTRW.w/WCWdVent through RoofWasherWithWater ClosetWoodVPVapor ProtectedWHWater Heaterw/iWithinw/oWithoutExist.ExistingSpecs.SpecificationsComp. A/C CompressorATRAll Thread RodSGDSliding Glass DoorSSStainless SteelFBCEFlorida Bldg. Code-ExistingTrung T LeDigitally signed by Trung T Le DN: c=US, o=Unaffiliated, ou=A01410C0000016B15CFD9EC00003B1D, cn=Trung T Le Date: 2022.04.27 14:09:11 -04'00'By Toni Gindlesperger at 4:21 pm, Apr 28, 2022By Mike Jones at 2:43 pm, May 04, 2022 Exist.Exist.5'5'5'Exist.Exist.Exist.Exist.Exist.Exist.Exist.PROPOSED ADDITION(F.F.E. = 12.3)12.0' 12.0'17.0'17.0'5.0' 5.0' 5'5'-5"DRAWN BY:CHECKED BY:JOB #:SHEETDUFFIE RESIDENCE 760 REDFIN DR. ATLANTIC BACH, FL 32233TLDATE:TLTLE-DUFFIE4/18/22REVISIONS DATE SHEET TITLE:PROJECT:11x17 TRUNG T. LE, P.E.Florida License #77614# TEL: (321) 313-2502 1575 Bream St. Merritt Island, FL. 32952 CA# 33103 TLE Engineering, PLLCThis item has been digitally signed and sealed by Trung T. Le, PEon the date shown on the timestamp using a Digital Signature.Printed copies of this document are not considered signed andsealed and the signature must be verified on any electronic copies.SITE PLANSITE PLAN1"=20'PPNOTE:1.SITE PLAN CREATED FROM OWNER/CONTRACTOR PROVIDEDSURVEY. TLE ENGINEERING, PLLC IS NOT RESPONSIBLE FORSURVEY ERRORS.2.ALL AREAS WITHIN 10 FEET OF STRUCTURE TO BE SLOPEDMINIMUM 5% AWAY FROM STRUCTURE, U.N.O.3.THIS SITE PLAN HAS BEEN DESIGNED SO THAT THE RUN-OFF FROMTHIS SITE DOES NOT ADVERSELY AFFECT ADJACENT PROPERTIES.4.PROVIDE SILT FENCE AS REQUIRED DURING CONSTRUCTION.5.ALL EXISTING GRADES SHALL REMAIN. NO PROPOSEDALTERATIONS WILL BE DONE TO THE EXISTING GRADES.IMPERVIOUS AREAEXISTINGBUILDING(S)OTHERS (DECKS, POOL, DRIVEWAYS, ETC.)PROPOSEDBUILDING(S) TOTALLOT AREAIMPERVIOUS %1,559 Sq. Ft.367 Sq. Ft.289 Sq. Ft. 2,215 Sq. Ft.7,502 Sq. Ft.29.5 %IMPERVIOUS SURFACE RATIO (I.S.R.)NORTHTrung T LeDigitally signed by Trung T Le DN: c=US, o=Unaffiliated, ou=A01410C0000016B15CFD9EC00003B1D, cn=Trung T Le Date: 2022 .04.27 14:09:32 -04'00' PORCH8'-0" Clg.5'-0"12'-0" 2'-7"6'-10"2'-7"17'-0"1'-0"1'-0"3'-0"8'-0"4'-6"11'-6"7'-412"4'-712"1'-10"8'-2"7'-0"STUDIOVAULT Clg.2068 Pkt.2668 Pkt.Temp. Gls.Shwr. Encl.Lav.WC3030 HR 3030 HR2616 FG 2616 FG5068 SGDComp.PROVIDE MINI-SPLITA/C UNIT FORADDITION (LOCATION& DESIGN BY OTHERS)8"13'-8"8"8x8 Col.D22D1920 AMP PREWIREFOR MINI-SPLIT(VERIFY LOCATION)SSSGFISSSWRGFIComp.DRAWN BY:CHECKED BY:JOB #:SHEETDUFFIE RESIDENCE 760 REDFIN DR. ATLANTIC BACH, FL 32233TLDATE:TLTLE-DUFFIE4/18/22REVISIONS DATE SHEET TITLE:PROJECT:11x17 TRUNG T. LE, P.E.Florida License #77614# TEL: (321) 313-2502 1575 Bream St. Merritt Island, FL. 32952 CA# 33103 TLE Engineering, PLLCThis item has been digitally signed and sealed by Trung T. Le, PEon the date shown on the timestamp using a Digital Signature.Printed copies of this document are not considered signed andsealed and the signature must be verified on any electronic copies.FLOOR PLAN& ELECT.LAYOUT01FLOOR PLAN1/8"=1'-0"NOMINAL WIDTH (X'-X")DOOR/ WINDOW SIZE LEGEND XXXXNOMINAL HEIGHT (X'-X")HATCH INDICATES NEW 2x4 FRAMING(LOAD Brg.) STUDS @ 16" O.C. REFERTO Dtl. 1/D2FLOOR PLAN NOTESCOMPONENT DESIGN PRESSURE (pasd)CONDITIONED AREA (A/C)LIVINGUNCONDITIONED AREAPORCHTOTAL UNDER ROOF204 Sq. Ft.85 Sq. Ft.289 Sq. Ft.INDICATES NEW 2x4 (U.N.O.)NON-LOAD BEARING FRAME WALLSTUDS @ 24" O.C. REFER TO Dtl. 6/D11.WINDOW AND DOOR SUPPLIERS SHALLPROVIDE CURRENT ROUGH OPENING Info.WHICH SHALL HAVE PRECEDENCE OVER THEWINDOW AND DOOR SCHEDULES ON PLAN.WINDOWS & DOORS TO COMPLY WITH 2020FBC (7th EDITION) ENERGY EFFICIENCY CODE.2.DO NOT SCALE PLANS. DIMENSIONS ARE TO BEFOLLOWED AS NOTED.3.GC TO VERIFY ALL DIMENSIONS WITH FIXTURESTO BE INSTALLED TO ENSURE COMPLIANCE4.H.V.A.C. SYSTEM TO BE SIZED AND DESIGNED BYH.V.A.C. CONTRACTOR.5.REFER TO FLOOR PLAN FOR CEILING HEIGHTS.6.CONTRACTOR SHALL VERIFY ALL DIMENSIONSAND EXISTING CONDITIONS AT SITE BEFOREPROCEEDING WITH ANY WORK.7.NOTES INDICATING TYPICAL CONDITIONSSHALL APPLY TO ALL LIKE AREAS UNLESSNOTED OTHERWISE.8.IF WATER BASED CEILING TEXTURE IS USED,PROVIDE 12" GYPSUM BOARD FOR 16" O.C.FRAMING OR 58" GYPSUM BOARD FOR 24" O.C.FRAMING (12" SAG-RESISTANT GYPSUM BOARDMAY BE USED I.L.O. OF 58" GYPSUM).9.ANCHOR THE CONDENSER UNIT TO SLAB USING14"x1 14" TAPCONS TO ATTACH 4" 'L' BRACKETSINTO THE PAD AND THEN USE 34" LONG SELFDRILLING SCREWS, (2) ON EACH CORNER TOATTACH THE 'L' BRACKETS TO THE EQUIPMENT.FLLOR PLAN LEGENDSQUARE FOOTAGENORTHELECTRICAL LAYOUT1/8"=1'-0"ELECTRICAL NOTES1.THIS ELECTRICAL PLAN IS TO BE USED FOR PLACEMENTPURPOSES ONLY. VERIFY LOCATION OF ALL COMPONENTSw/ HOMEOWNER PRIOR TO COMMENCEMENT OF WORK.DESIGN AND CALCULATIONS TO BE THE RESPONSIBILITYOF THE ELECTRICAL CONTRACTOR.2.ALL ELECTRICAL WORK SHALL CONFORM TO NEC 2017.3.ALL WIRING IS TO BE #14 AWG OR LARGER (SIZE PER NEC)SOLID COPPER TYPE THHN AND ELECTRICAL SERVICEWIRING TO BE TYPE THW OR THWN. ALL WIRING IS TO BESHEATHED NM OR NMC WHERE Req'd. (ROMEX).4.USE CLAMPING TYPE ROMEX CONNECTORS AT EACH BOX.5.LOCATION OF EXISTING UNDERGROUND UTILITY LINESAND STRUCTURES SHALL BE DETERMINED AND VERIFIED INTHE FIELD PRIOR TO COMMENCING WORK, ELECTRICALCONTRACTOR SHALL BE RESPONSIBLE FOR HIS/HERDAMAGE TO OTHER TRADES.6.ELECTRICAL BOXES INSTALLED IN FLOORS, WALLS, ORCEILINGS SHALL BE MOUNTED FLUSH WITH FINISHEDSURFACE AND CONDUITS AND/OR CABLES SHALL BECONCEALED UNLESS OTHERWISE NOTED.7.OUTLETS FOR EXTERIOR, GARAGE, KITCHEN COUNTER,DISHWASHER, BATHROOM OR ANY OUTLETS WITHIN 6' OFA SINK TO BE GFI. EXCEPTIONS FROM GFI REQUIREMENTSSHALL BE PERMITTED PROVIDED LOCATION ARE ALLOWEDPER NEC 2017.8.ARC-FAULT CIRCUIT-INTERRUPTER PROTECTION FORDWELLING UNITS (NEC 2017, SECTION 210.12 A): ALL120-VOLT, SINGLE PHASE 15-20 AMP BRANCH CIRCUITSTHAT SUPPLY OUTLETS IN KITCHENS, FAMILY ROOMS,DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES,DENS, BEDROOMS, SUNROOMS, RECREATION ROOMS,CLOSETS, HALLWAYS, LAUNDRY AREAS, OR SIMILARROOMS OR AREAS SHALL BE PROTECTED BY ANY OF THEMEANS DESCRIBED IN THE 2017 NEC, SECTION 210.12(A) 1THROUGH 6.9.TAMPER-RESISTANT RECEPTACLES FOR DWELLING UNITS(NEC 2017, SECTION 406.12): REQUIRED IN ALL AREAS ASSPECIFIED IN SECTION 210.52 AND 550.13, FOR ALLNON-LOCKING TYPE 125V AND 250V, 15-20 AMPRECEPTACLES.10.EACH CIRCUIT IS TO HAVE CONTINUOUS SOLID COPPERBARE GROUND WIRE CONNECTED TO EQUIPMENTGROUND BAR IN THE MAIN DISTRIBUTION PANEL.ALTERNATE INSTALLATION OF A GREEN PIGTAIL FROM THEGROUND SCREW TO THE LUG ON THE BOX WHERE THEGREEN GROUND WIRE IS CONNECTED (IF METAL BOX).11.WIRING ON EXPOSED SURFACES SHALL BE PROTECTEDFROM PHYSICAL DAMAGE WHERE NECESSARY BY METALOR SCHEDULE 80 PVC CONDUIT.12.ALL SMOKE DETECTORS TO BE INSTALLED PER NEC 2017 &SECTION R314 OF THE 2020 FLORIDA BUILDING CODE(RESIDENTIAL), 7th EDITION.ELECTRICAL LEGENDSSDSWITCH, SINGLE POLEOUTLET (120V)OUTLET (120V), ABOVE COUNTEROUTLET (120V), GROUND FAULT CIRCUIT INTERRUPTEROUTLET (120V), WEATHER-RESISTANT G.F.I.OUTLET (220-240V), DEDICATEDLIGHT FIXTURE, CEILING MOUNTEDLIGHT FIXTURE, WALL MOUNTEDLIGHT FIXTURE, HANGINGLIGHT FIXTURE, RECESSEDLIGHT FIXTURE, RECESSED VAPOR PROOFLIGHT FIXTURE, TRACKLIGHT FIXTURE, FLUORESCENT FIXTURELIGHT FIXTURE, FLOOD LIGHTSSMOKE DETECTORCARBON MONOXIDE DETECTOREXHAUST FANDISCONNECT SWITCHELECTRICAL PANELJUNCTION BOXCEILING FAN, INSTALLEDG.F.I.WRG.F.I.VPTrung T LeDigitally signed by Trung T Le DN: c=US, o=Unaffiliated , ou=A01410C0000016B15CFD9EC00003B1D, cn=Trung T Le Date: 2022.04.27 14:09:48 -04'00' 0'-0"FIN. FLR.11'-3"BEARING8'-0"BEARINGBd. & Bat. FIBER CEMENTSIDING (INSTALL PER Manuf.Specs.) ON APPROVEDWATER-RESISTIVE BARRIEROVER WALL SHEATHINGSTANDING METALROOF PANELS8" OH Typ.4" TRIM.Typ.8"x8" FINISHEDPOST9"(4) 3010 FG8"8"8"0'-0"FIN. FLR.9'-4"BEARING0'-0"FIN. FLR.9'-4"BEARING8'-0"BEARINGBd. & Bat. FIBER CEMENTSIDING (INSTALL PER Manuf.Specs.) ON APPROVEDWATER-RESISTIVE BARRIEROVER WALL SHEATHING6'-8"0'-0"FIN. FLR.11'-3"BEARING11'-3"BEARINGBd. & Bat. FIBER CEMENTSIDING (INSTALL PER Manuf.Specs.) ON APPROVEDWATER-RESISTIVE BARRIEROVER WALL SHEATHING122122121/21'-4" OH Typ.8"x8" FINISHEDPOST4" TRIM.Typ.4" TRIM.Typ.121/28"x8" FINISHEDPOST8'-0"BEARING6'-0"0'-0"FIN. FLR.9'-4"BEARINGASPHALT SHINGLESBd. & Bat. FIBER CEMENTSIDING (INSTALL PER Manuf.Specs.) ON APPROVEDWATER-RESISTIVE BARRIEROVER WALL SHEATHING8" OH Typ.DRAWN BY:CHECKED BY:JOB #:SHEETDUFFIE RESIDENCE 760 REDFIN DR. ATLANTIC BACH, FL 32233TLDATE:TLTLE-DUFFIE4/18/22REVISIONS DATE SHEET TITLE:PROJECT:11x17 TRUNG T. LE, P.E.Florida License #77614# TEL: (321) 313-2502 1575 Bream St. Merritt Island, FL. 32952 CA# 33103 TLE Engineering, PLLCThis item has been digitally signed and sealed by Trung T. Le, PEon the date shown on the timestamp using a Digital Signature.Printed copies of this document are not considered signed andsealed and the signature must be verified on any electronic copies.ELEVATIONS02FRONT ELEVATION1/8"=1'-0"RIGHT ELEVATION1/8"=1'-0"LEFT ELEVATION1/8"=1'-0"REAR ELEVATION1/8"=1'-0"NOMINAL WIDTH (X'-X")DOOR/ WINDOW SIZE LEGEND XXXXNOMINAL HEIGHT (X'-X")COMPONENT DESIGN PRESSURE (pasd)Trung T LeDigitally signed by Trung T Le DN: c=US, o=Unaffiliated, ou=A01410C0000016B15CFD9EC00003B1D, cn=Trung T Le Date: 2022 .04.27 14:10:08 -04'00'