760 REDFIN DR ACC22-0022 Energy Calc - Duffie guest house_1FORM R405-2020
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation -Residential Performance Method
Project Name:
Street:
City, State, Zip:
Owner:
Guest -760 Redlin Dr
760 Redfin Dr
Atlantic Beach, FL, 32233
Builder Name:
Permit Office: Atlantic Beach
Permit Number:
Jurisdiction: 261100
Design Location: FL, Jacksonville County: Duval(Florida Climate Zone 2)
1. New construction or existing
2. Single family or multiple family
3. Number of units, if multiple family
4. Number of Bedrooms
5. Is this a worst case?
6. Conditioned floor area above grade (ft2)
Conditioned floor area below grade (ft2)
New (From Plans)
Detached
1
0
No
204
0
7. Windows(59.8 sqft.) Description
a. U-Factor: Dbl, U=0.35
SHGC: SHGC=0.25
b. U-Factor: Dbl, U=0.34
SHGC: SHGC=0.21
c. U-Factor: Dbl, U=0.32
SHGC: SHGC=0.24
Area Weighted Average Overhang Depth:
Area Weighted Average SHGC:
8. Skylights Description
U-Factor:(AVG) N/A
SHGC(AVG): N/A
9. Floor Types
a. Slab-On-Grade Edge Insulation
b. N/A c. NIA
Insulation
R= 0.0
R=
R=
Area
33.50 ft2
18.00 ft2
8.27 ft2
2.000 ft
0.237
Area
N/A ft2
Area
204.00 ft2
ft2
ft2
10. Wall Types(580.0 sqft.)
a. Frame -Wood, Exterior
b. N/A
c. NIA
d. NIA
11. Celling Types(204.0 sqft.)
a. Under Attic (Vented)
b. N/A
c. N/A
12. Ducts, location & insulation level
a.
b.
C.
13. Cooling Systems
a. Central Unit
14. Heating Systems
a. Electric Heat Pump
15. Hot Water Systems
a. Electric
b. Conservation features
16. Credits
Glass/Floor Area: 0.293 Total Proposed Modified Loads: 10.45
12.38 Total Baseline Loads:
I hereby certify that the plans and specifications covered by
this calculation are in compliance with the Florida Energy
Code.
PREPARED BY:~uc,, ,5auft~ E-Calcs Plus, Inc.
DATE: April e,2022
I hereby certify that this buildin
with the Florida Energy Co
Review of the plans and
specifications covered by this
calculation indicates compliance
with the Florida Energy Code.
Before construction is completed
this building will be inspected for
compliance with Section 553.908
Florida Statutes.
Insulation
R=13.0
R=
R=
R=
Insulation
R::30.0
R=
R=
Area
580.00 ft2
ft2
ft2
ft2
Area
204.00 ft2
ft2 ft2
R ft2
kBtu/hr Efficiency
12.0 SEER:17.00
kBtu/hr Efficiency
12.0 HSPF:9.00
Cap: 40 gallons
EF: 0.950
PASS
None
Pstat
OWNER/AGE ,---1'-E~';Jt.~==-----
DATE: _~H-J'O--/--"""I..£::-=--------
BUILDING OFFICIAL: _________ _
DATE: _______________ _
-Compliance requires certHlcatlon by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory-sealed In accordance with R403.3.2.1.
-Proposed Qn of NAN exceeds the perfonnance method default llmlt of 0.08
and therefore does not require duct testing. R405 .2.3
-Compliance requires an Air Barrier and lnsulatlon Inspection Checklist In accordance with R402.4.1.1 and this project
requires a PERFORMANCE envelope leakage test report with envelope leakage no greater than 7 .00 ACH50 (R402.4.1.2).
4/8!2022 7:59:28 AM EnergyGauge® USA 7.0.00-FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1
By Toni Gindlesperger at 9:30 am, Apr 27, 2022