Loading...
760 REDFIN DR ACC22-0022 Energy Calc - Duffie guest house_1FORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation -Residential Performance Method Project Name: Street: City, State, Zip: Owner: Guest -760 Redlin Dr 760 Redfin Dr Atlantic Beach, FL, 32233 Builder Name: Permit Office: Atlantic Beach Permit Number: Jurisdiction: 261100 Design Location: FL, Jacksonville County: Duval(Florida Climate Zone 2) 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area above grade (ft2) Conditioned floor area below grade (ft2) New (From Plans) Detached 1 0 No 204 0 7. Windows(59.8 sqft.) Description a. U-Factor: Dbl, U=0.35 SHGC: SHGC=0.25 b. U-Factor: Dbl, U=0.34 SHGC: SHGC=0.21 c. U-Factor: Dbl, U=0.32 SHGC: SHGC=0.24 Area Weighted Average Overhang Depth: Area Weighted Average SHGC: 8. Skylights Description U-Factor:(AVG) N/A SHGC(AVG): N/A 9. Floor Types a. Slab-On-Grade Edge Insulation b. N/A c. NIA Insulation R= 0.0 R= R= Area 33.50 ft2 18.00 ft2 8.27 ft2 2.000 ft 0.237 Area N/A ft2 Area 204.00 ft2 ft2 ft2 10. Wall Types(580.0 sqft.) a. Frame -Wood, Exterior b. N/A c. NIA d. NIA 11. Celling Types(204.0 sqft.) a. Under Attic (Vented) b. N/A c. N/A 12. Ducts, location & insulation level a. b. C. 13. Cooling Systems a. Central Unit 14. Heating Systems a. Electric Heat Pump 15. Hot Water Systems a. Electric b. Conservation features 16. Credits Glass/Floor Area: 0.293 Total Proposed Modified Loads: 10.45 12.38 Total Baseline Loads: I hereby certify that the plans and specifications covered by this calculation are in compliance with the Florida Energy Code. PREPARED BY:~uc,, ,5auft~ E-Calcs Plus, Inc. DATE: April e,2022 I hereby certify that this buildin with the Florida Energy Co Review of the plans and specifications covered by this calculation indicates compliance with the Florida Energy Code. Before construction is completed this building will be inspected for compliance with Section 553.908 Florida Statutes. Insulation R=13.0 R= R= R= Insulation R::30.0 R= R= Area 580.00 ft2 ft2 ft2 ft2 Area 204.00 ft2 ft2 ft2 R ft2 kBtu/hr Efficiency 12.0 SEER:17.00 kBtu/hr Efficiency 12.0 HSPF:9.00 Cap: 40 gallons EF: 0.950 PASS None Pstat OWNER/AGE ,---1'-E~';Jt.~==----- DATE: _~H-J'O--/--"""I..£::-=-------- BUILDING OFFICIAL: _________ _ DATE: _______________ _ -Compliance requires certHlcatlon by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed In accordance with R403.3.2.1. -Proposed Qn of NAN exceeds the perfonnance method default llmlt of 0.08 and therefore does not require duct testing. R405 .2.3 -Compliance requires an Air Barrier and lnsulatlon Inspection Checklist In accordance with R402.4.1.1 and this project requires a PERFORMANCE envelope leakage test report with envelope leakage no greater than 7 .00 ACH50 (R402.4.1.2). 4/8!2022 7:59:28 AM EnergyGauge® USA 7.0.00-FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 By Toni Gindlesperger at 9:30 am, Apr 27, 2022 By Mike Jones at 3:42 pm, May 04, 2022