760 REDFIN DR ACC22-0022 Energy Display Card - Duffie guest house_1FORM R405-2020
ENERGY PERFORMANCE LEVEL (EPL) DISPLA V CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 84
The lower the EnergyPerformance Index, the more efficient the home.
760 Redfin Dr.Atlantic Beach,FL,32233
1. New construction or existing
2. Single family or multiple family
3. Number of units, if multiple family
4. Number of Bedrooms
5. Is this a worst case?
6. Conditioned floor area above grade (ft2)
Conditioned floor area below grade (ft2)
7. Windows•• Description
a. U-Factor: Dbl, U=0.35
SHGC: SHGC=0.25
b. U-Factor: Dbl, U=0.34
SHGC: SHGC=0.21
c. U-Factor: Dbl, U=0.32
SHGC: SHGC=0.24
Area Weighted Average Overhang Depth:
Area Weighted Average SHGC:
8. Skylights Description
U-Factor:(AVG) N/A
SHGC(AVG): N/A
New (From Plans)
Detached
1
0
No
204
0
Area
33.50 ft2
18.00 ft2
8.27 ft2
2.000 ft
0.237
Area
N/A ft2
9. Floor Types
a. Slab-On-Grade Edge Insulation
b. N/A
Insulation
R= 0.0
R=
Area
204.00 ft2
ft2
c. N/A R= ft2
10. Wall Types(580.0 sqft.)
a. Frame -Wood, Exterior
b. N/A
c. N/A
d. N/A
11. Ceiling Types(204.0 sqft.)
a. Under Attic (Vented)
b. N/A
c. N/A
12. Ducts, location & insulation level
a.
b.
C.
13. Cooling Systems
a. Central Unit
14. Heating Systems
a. Electric Heat Pump
15. Hot Water Systems
a. Electric
b. Conservation features
16. Credits
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features.
BW~e, S~natu,ec lf};zi/fi
Address of New Home: 760 Redfin Dr City/FL Zip: Atlantic Beach,FL,32233
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for
energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the
Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
Insulation
R=13.0
R=
R=
R=
Insulation
R=30.0
R=
R=
Area
580.00 ft2
ft2
ft2
ft2
Area
204.00 ft2
ft2
ft2
R ft2
kBtu/hr Efficiency
12.0 SEER:17.00
kBtu/hr Efficiency
12.0 HSPF:9.00
Cap: 40 gallons
EF: 0.950
None
Pstat
418f2()22 7:59:28 AM EnergyGauge® USA 7.0.00 -FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 1
By Toni Gindlesperger at 9:32 am, Apr 27, 2022