Loading...
760 Redfin Dr ACC22-0022 Guest House Metal Roof certification and installation - REV. 6-14-22r-\ . J ; Metal Roof Certification & Listing Program KEYSTO NE CERTIFICATIONS, INC. \ -\ ,__, Certification Report 11030-002-KCI .061.l LSO/lEC 17065 P'rod.nCa1ific-nionlody 145 Limekiln Road, Suite 1008 ' 1 'New CUmberl~~d, PA 17070 '\ • • l Ji: 1 ' ' www.keystonecerts.com ' Construction Specifications Institute (CSI) category: Division: 07 00 00 -Thermal & Moisture Protection Section: 07 4113 -Metal roof and wall panels 1. Program Ucensee: ~ 1 51 COAST METAL ROOFING SUPPLY 1st Coast Metal Roofing Supply 186SR207 East Palatka, FL 32131 386-325-0242 http://www.lstcoastmrs.com/ 2. Certified Roof Covering: 1st Coast Metal Roofing Supply's Model Armour R_ib 29 Ga. non-structural through-fastened metal roof and wall panels installed over plywood sheathing roof deck for use in new construction, re-roofing and re-covering applications. 3. Scope of Certification: This Certification Report provides technical data substantiating that the use of the certified roof covering and the evaluated roof systems are in compliance with the following: • 2020 Florida Building Code -Building, 7th Edition, Section 1504.3.2. • Florida Product Approval Rule 61620-3. Properties Evaluated: • Wind Uplift Resistance • Resistance to Foot Traffic , , lssue'D~ted: '10hi/2"b11 lj ,, , {R~vj~ion D1;1te: · · 1/ll/20il· • 1 i;;i'fl .· . _Expl~tlon.·oate: ,, 1011:iJ202r,, i. :1 This Certification Report was used to qualify Florida Product Approval FL 24397-R6. 4. Evaluated Roof System Description: 4.1. Roof Covering: Armour Rib 29 Ga. metal roof and wall covering panels are cold roll-formed from minimum 29 gauge ASTM A792 Grade 80 steel sheet. The panels are aluminum-zinc alloy coated per ASTM A792 (AZS0), and shall be installed in accordance with the manufacturer's instructions and this Certification Report. 4.2. Roof Deck: Armour Rib Panel metal roof and wall panels are certified for use over solid or closely-spaced, nominal 15/32" B-C 4 Ply Plywood sheathing complying with 2020 Florida Building Code -Building, 7th Edition, Section 2303.1.5, with or without the use of lx4 #2 SWP purlins at 24" O.C., with a minimum slope of 4% (1/2:12). Lap sealant shall be applied for installed slopes less than 25% (3:12). When used, lx4 purlins are attached through the sheathing and into the rafters using (2) 8x3" deck screws max. 24" O.C. 4.3. Anchorage: Armour Rib 29 Ga. metal roof and wall panels shall be through-fastened to the purlins or roof deck using #10-15 x 1-1/2" Woodgrip hex-head wood screws with bond-seal washer or equivalent, as specified in Table 1, applied in the patterns described in Appendix 1. 4.4. Underlayment: Armour Rib 29 Ga. metal roof panels in new construction applications shall be installed over underlayment meeting the applicable material type and attachment details specified in 2020 Florida Building Code -Building, 7th Edition Table 1507.1.1.1., the manufacturer's installation instructions and this Certification Report. Refer to www.keystonecerts.com to ascertain the ongoing status of this Certification Report. Approval of building products and/or materials can only be granted by the building official having jurisdictional legal authority. Keystone Certifications, Inc. does not endorse or make warranties with respect to product performance or suitabillty of a product for a given use. By Toni Gindlesperger at 11:04 am, Jun 14, 2022 By Mike Jones at 3:34 pm, Jun 25, 2022 Metal Roof Certification & Listing Program Certification Report 11030-002-KCI 0 •0&12 ISO/JEC 17°'5 h-odua c:.m&uioa llodr Page2o/4 Installation Armour Rib ~9 Ga. metal roof and wall panels in new construction applications shall be installed in accordance with the 2020 Florida Building Code -Building, 7th Edition, Section 1507.4, the manufacturer's published installation instructions and this Certification Report. Armour Rib 29 Ga. metal roof and wall panels in re- roofing and re-covering applications may be installed over a single layer of existing shingles and shall be installed in accordance with the 2020 Florida Building Code -Building, 7th Edition, Sections 1507 .4 & 1511, the manufacturer's published installation instructions and this Certification Report. The manufacturer's installation instructions shall be made available at the time of installation., If there are differences between this report and the manufacturer's installation instructions, this · report · shall take precedence. S. Product Performance The performance of the Armour Rib 29 Ga. non- structural through-fastened metal roof and wall panels described in this Certification Report has been determined in accordance with: • UL 580-94, Tests for Uplift Resistance of Roof Assemblies. • UL 1897-98, Uplift Tests/or Roof Covering Systems. • FM 4470, Resistance to Foot Traffic Test. As tested & reported by the following independent accredited laboratory: Laboratory Report Ref. Force Engineering & Testing 384/593-0030T-10A, B 384/593-0030T-10C, D 384/593-0030T-10E Note: The UL 580-94 standard is equivalent to the UL 580-06 standard, the UL 1897-04 standard is equivalent to the UL 1897-2012 standard, and the FM 4470-12 standard is equivalent to the FM 4470-16 standard. 5.1. Wind Resistance The allowable design uplift pressures for Armour Rib 29 Ga. an.chored as described in Table 1 and illustrated in )\ppendix 1, when tested in accordance with the referenced standards with an applied safety factor of 2.0 are found in Table 1. Table 1 Max Anchor Description Anchor Man'f & Design Pattern Model Uplift . Pressure Over 15/32" SFS Hilo 4 Ply A Woodgrip 78.S psf #10-15 X 1-Plywood 1/2" - SFS Hilo Over 15/32" 4 Ply B Woodgrip 108.S psf #--10-15 X 1-Plywood 1/.2" --·------Over lx4 SFS Hilo Purlins Over A Woodgrip 108.5 psf 15/32" 4 Ply #10-15 X 1- Plywood 1/2" Over lx4 SFS Hilo Purlins Over B Woodgrip 183.5 psf 15/32" 4 Ply #10-15 X 1- Plywood 1/2" Refer to www.kevstonecerts.com to ascertain the ongoing status of this Certification Report. Approval of building products and/or materials can only be granted by the building official having Jurisdictional legal authority. Keystone Certifications, Inc. does not endorse or make warranties with respect to product performance or suitability of a product for a given use. I \ I . l<EYSTO~ C E RTIF I C ATIONS, INC. '-' I _J Metal Roof Certification & Listing Program Certification Report 11030-002-KCI "°'" ISO/IIC 1706' PNd,,w, C..-Uftunon lodJ Page3o/4 5.2. Resistance to Foot Traffic The Armour Rib 29 Ga. non-structural through-fastened metal roof and wall panels were tested per the referenced standard installed using Anchor Pattern A over 1x4 SWP purlins over 15/32n 4 ply plywood. The resultant deflection under load and permanent deflection were within the allowable limits defined by the standard. 6. Conditions of Use Armour Rib 29 Ga. non-structural through-fastened metal roof and wall panels must be insulated against other materials or metals including concrete, lead, copper and treated lumber that contains corrosive materials. 7. Limitations of Use Armour Rib 29 Ga. non-structural through-fastened metal roof and wall panels are !!.Qt qualified for use in the High Velocity Hurricane Zone (HVHZ). Fire classification, shear diaphragm design, roof deck design & attachment to supporting members are not within the scope of this Certification Report. Roof support framing shall comply with 2020 Florida Building Code -Building, 7th Edition, Chapter 22 for steel, Chapter 23 for wood and Chapter 16 for structural loading. 8. Licensed Manufacturing Facilities This Certification Report is applicable only to Armour Rib 29 Ga. non-structural through-fastened metal roof and wall panels manufactured at the following locations: 1st Coast Metal Roofing Supply 186 State Rd 207 East Palatka, Florida 32131 Each licensed facility is subject to periodic inspection by Keystone Certifications to verify conformance with Keystone Roof Covering Certification & Listing Program requirements. 9. Identification Armour Rib 29 Ga. non-structural through-fastened metal roof and wall panels represented by this report shall be identified with Keystone Roof Covering Certification & Listing Program certification labeling illustrated below, to be applied to individual panels, packaging, invoicing or bills of lading: keystonecerts.com 11030-002-KCI 2021.01.1 +--11-~f~ 1 09:35:41 -05'00' Aaron M. Shultz Validation Manager Refer to www.keystonecerts.com to ascertain the ongoing status of this Certification Report. Approval of building products and/or materials can only be granted by the building official having Jurisdictional legal authority. Keystone Certifications, Inc. does not endorse or make warranties with respect to product performance or suitability of a product for a given use. Appendix 1 Anchor Pattern A ~C'ii UNOCRl4YMCNT (l!!:OUl!iED (r,'I.Y fOR HEW CO>iSIRUCIION) ARMOUR RI& AAMOURIU8 MK 2lf_ WOOD 11.AFT[R/JOIST/ {Rt)SS Al W.X, 2•• O.C. MIN 2X_ WOOi) RAFW!/ JCllS1 / TRUSS Al MU. 2•• O.C. DOSTl'IG Sjj!NGLES' (OPIIO.'</,l) Metal Roof Certification & Listing Program Certification Report 11030-002-KCI Page4 o/4 Note: In all cases (new construction, re-roofing and re- covering), the anchors shall fully penetrate the purlins or the plywood roof deck (as applicable). NCW ll\GfRl'AYl.l:tNT :\ (qfQUIR£D ONt Y FOR S(W C0051i'UC!ION) / ROWS~f10-15x 1·11'2"SfSHla I 9· (TYP.)--- •'OOOOOIP• 24"0.C. M!KIMUM A.H:ACHMENT: ea,2.5"t.a<GR!NCSIWIKNAA. OR #8 , 2" LO>.c II000 SCR£WS SPACl'D O a· o.c. IN TM£ riru;, .t Al EDC(S . FA!l1EJUM1JfRIIMPAllfl-OOS l.f!Ntt.llAI ATTAC.HM(t{J: ed , 2.s· lONC RJNC .St~NIC NA,'L OR f6 , 2• LONG II000 SCl!!:WS -Sf\11:(0 0 6° O.C. l!I 1\;£ Fl(LO & AT EoctS PI.Y.-000 1~/ J2• 1ltCI< (""'-) ROWSOff10-15 x 1-112" SFSHlo r =••2•· 0.c. "'"'l!UI.I All~ T1 Bd'< 2S LONG l!;!fG -~ NAil. OR ta • 2" lONC II000 SCRCWS sPAC(O O 6° 0.C. IN llj( r1ELO & Al (DG£S Refer to www.keystonecerts.com to ascertain the ongoing status of this Certification Report. Approval of building products and/or materials can only be granted by the building official having jurisdictional legal authority. Keystone Certifications, Inc. does not endorse or make warranties with respect to product performance or suitability of a product for a given use. 145 Limekiln Road, Suite 100B New Cumberland, PA 17070 www.keystonecerts.com Rev# Date 0 10/27/2017 1 1/8/2018 2 1/23/2018 3 6/25/2()18 4 03/12/2019 5 9/3/2019 6 10/3/2019 7 10/12/2020 8 1/11/2021 Metal Roof Certification & Listing Program Certification Report 11030-002-KCI Issue Dated: Revision Date: Expiration Date: Certificate Revisions Description Initial issuance. Added reference to associated Florida Product Approval No 24397. Added hyperlink to FL24397 ISO/ltc 1706S Prodao: c.a&moa 10/27/2017 1/11/2021 10/12/2025 ., Removed refs to measurements for mat'I thickness and yield strength, relying on applicable Gauge and steel Grade. Added ref to lx4 purlin anchorage. Updated Model name to include metal roof "and Wall panels" Updated ANSI Logo to proper requirements. Revised anchorage illustrations for clarity, added reference to optional re-roofing / re-covering installation over "one layer of existing shingles». Updated to 2020 FBC 7th Edition. Corrected Model name. Updated FPA link. Refer to www.keystonecerts.com to ascertain the ongoing status of this Certification Report. Approval of building products and/or materials can only be granted by the building official having jurisdictional legal authority. Keystone certifications, Inc. does not endorse or make warranties with respect to product performance or suitability of a product for a given use.