Loading...
376 10th St RES21-0373 Lucerno Residence Revised Final Plan REVISION 4-29-22WINDOW AND EXTERIOR DOOR FLASHING 45 DEG. CUT FOLD FLAP UP AND TEMPORARILY TAPE APPLY A BEAD OF SEALANT TO THE HEAD AND JAMBS OF THE WINDOW FLANGE INSTALL WINDOW LEVEL AND PLUMB INTO OPENING AND FASTEN ACCORDING TO MANUFACTURER'S INSTALLATION INSTRUCTIONS APPLY HEAD FLASHING TO EXTEND PAST THE JAMB FLASHING, USE A J-ROLLER TO SET AND FLATTEN PULL TEMPORARY TAPE FROM FLAP AND FOLD OVER TOP OF THE WINDOW FLANGE, TAPE 45 DEG. CUTS WRB WRB WRB WRB WRBWRB CUT DOWN CENTER AND ACROSS TOP AND THE BOTTOM FOLD FLAPS IN AND ATTACH TO SIDE JAMBS INSTALL SILL FLASHING INSIDE BOTTOM JAMB LAPPING OVER WRB DOWN 6", APPLY FLASHING AT JAMB CORNERS, LAP UP JAMB MINIMUM 4" AND OVER TOP OF SILL FLASHING SILL FLASHING CORNER FLASHING INSTALL WRB IN A WATER SHED FASHION STARTING AT THE BOTTOM OF THE WALL AND WORKING TO THE TOP WITH OVERLAP PER THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. APPLY FLASHING STARTING 4" OVER THE SIDES OF THE WINDOW FLANGES, FOLLOW DOWN TO OVERLAP THE CORNER FLASHING, USE A J-ROLLER TO SET AND FLATTEN East Elevation Rear Elevation10'-1 1/8"1'-6 3/4"10'-1 1/8"2'1'-6"9'-1 1/8"2'32'-11 3/16"2ND FLOOR CEILING 2ND FLOOR 1ST FLOOR CEILING 1ST FLOOR HOME ELEVATION HEIGHTS 35' MAX HEIGHT 1ST FLOOR GARAGE CEILING RAISED HEEL PLATE GARAGE HEIGHTS 6 12 ARCHECTURAL ASPHALT SHINGLES DECORATIVE GABLE BRACKETS CEMENTIOUS BOARD AND BATTON SIDING 1"x 3" (3/4" THICK) TRIM BOARDS 1"X 4" (3/4" THICK) CEMENTIOUS SIDING TRIM 1"x 4" (1" THICK) CEMENTIOUS TRIM LOW-E VINYL WINDOWS STEEL CLAD INSULATED OHD VINYL SOFFITS & ALUMINUM FASCIA CEDAR SHAKE SIDING Street Elevation P-1REVISION TABLENUMBERDATEREVISED BYDESCRIPTIONSHEET: SCALE:DRAWINGS PROVIDED BY:PAGE TITLEDATE: 4/28/22ASHLAR HOME BUILDERS LLC5295 CR 209sGreen Cove Springs, FL 32043LUCERO RESIDENCE376 TENTH STREETATLANTIC BEACH, FL 32233 1ST FLOOR CONDITIONED 1332 SQ. FT. 2ND FLOOR CONDITIONED 1266 SQ. FT. TOTAL CONDITIONED 2598 SQ. FT. 1ST FLOOR UNDER ROOF 2382 SQ. FT. 2ND FLOOR UNDER ROOF 1578 SQ. FT. GARAGE 618 SQ. FT. TOTAL UNDER ROOF 3608 SQ. FT. NOTES (COMPLY W/ FLORIDA BUILDING CODE 2020- RESIDENTIAL) 1.FBC-R302.5.1: Openings from a private garage directly into a room used for sleeping purposes shall not be permitted. Other openings between the garage and residence shall be equipped with solid wood doors not less than 13/8 inches (35 mm) in thickness, solid or honeycombcore steel doors not less than 13/8 inches (35 mm) thick, or 20-minute fire- rated doors. 2.FBC-R302.5.2: Ducts in the garage and ducts penetrating the walls or ceilings separating the dwelling from the garage shall be constructed of a minimum No. 26 gage (0.48 mm) sheet steel, 1 inch (25.4 mm) minimum rigid nonmetallic Class 0 or Class 1 duct board, or other approved material and shall not have openings into the garage. 3.FBC-R302.6: The garage shall be separated as required by Table R302.6. Openings in garage walls shall comply with Section R302.5. Attachment of gypsum board shall comply with Table R702.3.5. The wall separation provisions of Table R302.6 shall not apply to garage walls that are perpendicular to the adjacent dwelling unit wall. 4. FBC-R, M1307.2: Appliances designed to be fixed in position shall be fastened or anchored in an approved manner. In Seismic Design Categories D0, D1 and D2, and in townhouses in Seismic Design Category C, water heaters and thermal storage units shall be anchored or strapped to resist horizontal displacement caused by earthquake motion in accordance with one of the following: 1.Anchorage and strapping shall be designed to resist a horizontal force equal to one-third of the operating weight of the water heater storage tank, acting in any horizontal direction. Strapping shall be at points within the upper one- third and lover one-third of the applianceʼs vertical dimensions. At the lower point, the strapping shall maintain a minimum distance of 4 inches (102 mm) above the controls. 2.The anchorage strapping shall be in accordance with the appliance manufacturerʼs recommendations. 5. FBC-R, M1305.1.1: Furnaces and air handlers within compartments or alcoves shall have a minimum working space clearance of 3 inches (76 mm) along the sides, back and top with a total width of the enclosing space being not less than 12 inches (305 mm) wider than the furnace or air handler. Furnaces having a firebox open to the atmosphere shall have not less than a 6-inch (152 mm) working space along the front combustion chamber side. Combustion air openings at the rear or side of the compartment shall comply with the requirements of Chapter 17. By Toni Gindlesperger at 1:09 pm, Apr 29, 2022 1:57 pm, May 10, 2022 6 : 12 6 : 12 6 : 12 6 : 126 : 12 6 : 126 : 12 6 : 126 : 12 6 : 126 : 12 6 : 12 6 : 126 : 12 6 : 126 : 12 ROOF PLAN (SCALE: 1/4"= 1')6'-4"West Elevation 10"7 3/4"2'-10"3'-2"3'4" MAX. STAIR RISE MIN. TREAD DEPTH PLANE OF TREAD NOSING MIN. HANDRAIL HEIGHT MAX. HANDRAIL HEIGHT MIN. HANDRAIL HEIGHT MAX. OPENING SPACING R311.7.5 Riser height. The riser height shall be not more than 73/4 inches (196 mm). The riser shall be measured vertically between leadingedges of the adjacent treads. The greatest riser height within any flight of stairs shall notexceed the smallest by more than 3/8 inch (9.5 mm). Risers shall be vertical or sloped from the underside of the nosing of the tread above at anangle not more than 30 degrees (0.51 rad) from the vertical. Open risers are permitted providedthat the openings located more than 30 inches (762 mm), as measured vertically, to the floor orgrade below do not permit the passage of a 4- inch-diameter (102 mm) sphere. R311.7.5.2 Tread depth. The tread depth shall be not less than 10 inches (254 mm). The tread depth shall be measured horizontally between the vertical planes of the foremost projection of adjacenttreads and at a right angle to the treadʼs leading edge. The greatest tread depth within any flight of stairs shall not exceed thesmallest by more than 3/8 inch (9.5 mm). R311.7.1 Width. Stairways shall be not less than 36 inches (914 mm) in clear width at all points above the permitted handrail height and below the required headroom height. The clear width of the stairway at and below the handrail height, including treads and landings, shall be not less than 311/2 inches (787 mm) where a handrail is installed on one side and 27 inches (698 mm) where handrails are provided on both sides. LANDING R311.7.8 Handrails. Handrails shall be provided on not less than one side of each flight with four or more risers. STAIR DETAIL REVISION TABLENUMBERDATEREVISED BYDESCRIPTIONSHEET: SCALE:DRAWINGS PROVIDED BY:DATE: 4/28/22ASHLAR HOME BUILDERS LLC5295 CR 209sGreen Cove Springs, FL 32043LUCERO RESIDENCE376 TENTH STREETATLANTIC BEACH, FL 32233"Z" FLASHING 29 GA. GALV. (NOT TO SCALE) METAL DRIP EDGE26 GA. GALVANIZED (NOT TO SCALE) 5 x 5 ANGLE FLASHING26 GA. GALVANIZED(NOT TO SCALE) ROOF FLASHING NOTES CRICKET AND SADDLE FLASHING: A CRICKET OR SADDLE SHALL BE INSTALLED ON THE RIDGE SIDE OF ANY CHIMNEY GREATER THAN 30" WIDE. CRICKET OR SADDLE COVERINGS SHALL BE SHEET METAL OR OF THE SAME MATERIAL AS THE ROOF COVERING. THE RIDGE AND VALLEY FLASHING OF CRICKETS OR SADDLES SHALL BE THE SAME AS THE RIDGE AND VALLEY FLASHING OF THE MAIN ROOF. BASE AND COUNTER FLASHING: BASE AND COUNTER FLASHES SHALL BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S INSTALLATION INSTRUCTIONS OR A CONTINUOUS METAL "L" FLASHING SHALL BE SET IN APPROVED FLASHING CEMENT AND SET FLUSH TO THE BASE OF WALL AND OVER THE UNDERLAYMENT. BOTH HORIZONTAL AND VERTICAL METAL FLANGES SHALL BE FASTENED 6" ON CENTER WITH APPROVED FASTENERS. ALL LAPS SHALL BE A MINIMUM OF 4" FULLY SEALED IN APPROVED FLASHING CEMENT. FLASHING SHALL START AT THE LOWER PORTION OF ROOF TO ENSURE WATER-SHEDDING CAPABILITIES OF ALL METAL LAPS. THE ENTIRE EDGE OF THE HORIZONTAL FLANGE SHALL BE SEALED COVERING ALL NAIL PENETRATIONS WITH APPROVED ROOFING CEMENT AND MEMBRANE. SHINGLES SHALL OVERLAP THE HORIZONTAL FLANGE AND SHALL BE SET IN APPROVED FLASHING CEMENT. BASE FLASHING SHALL BE EITHER CORROSION-RESISTANT METAL PROVIDED IN SECTION R905.2.8.1 OR MINERAL SURFACE ROLL ROOFING WEIGHING A MINIMUM OF 77 POUNDS PER 100 SQUARE FEET. COUNTER FLASHING SHALL BE CORROSION -RESISTANT METAL WITH A MINIMUM THICKNESS PROVIDED IN TABLE R903.1. FIBER CEMENT SIDING FLASHING: PANEL SIDING: PANELS SHALL BE INSTALLED WITH THE LONG DIMENSION PARALLEL TO FRAMING. VERTICAL JOINTS SHALL OCCUR OVER FRAMING MEMBERS AND SHALL BE SEALED WITH CAULKING OR COVERED WITH BATTENS. HORIZONTAL JOINTS SHALL BE FLASHED WITH "Z"-FLASHING AND BLOCKED WITH SOLID WOOD BLOCKING. HORIZONTAL LAP SIDING: LAP SIDING SHALL BE LAPPED A MINIMUM OF 1 1/4" AND SHALL HAVE THE ENDS SEALED WITH CAULKING, COVERED WITH AN H-SECTION JOINT COVER, OR LOCATED OVER A STRIP OF FLASHING. LAP SIDING COURSES MAY BE INSTALLED WITH THE FASTENER HEADS EXPOSED OR CONCEALED, ACCORDING TO APPROVED MANUFACTURER'S INSTALLATION INSTRUCTIONS. DRIP EDGE FLASHING: METAL DRIP EDGE OF 26 GA. GALVANIZED METAL. DRIP EDGE FLASHING SHALL BE PROVIDED AT EAVES AND GABLES OF SHINGLED ROOFS AND OVERLAPPED A MINIMUM OF 2". EAVE DRIP EDGES SHALL EXTEND 1/4" BELOW SHEATHING AND EXTEND BACK ON THE ROOF A MINIMUM OF 2" DRIP EDGE SHALL BE MECHANICALLY FASTENED A MAXIMUM OF 12" O.C. DRIP EDGE AT EAVES SHALL BE PERMITTED TO BE INSTALLED EITHER OVER OR UNDER THE UNDERLAYMENT. IF INSTALLED OVER THE UNDERLAYMENT, THERE SHALL BE A MINIMUM OF 2" WIDTH OF ROOF CEMENT INSTALLED OVER THE DRIP EDGE FLANGE. THE UNDERLAYMENT SHALL CONFORM WITH ASTM D 226 TYPE II, ASTM D 4869 TYPE IV OR ASTM D 6757 (ALL ARE EQUIVALENT TO A 30 LB. UNDERLAYMENT). THE UNDERLAYMENT SHALL BE INSTALLED IN A SHINGLE- FASHION AND LAPPED 19 INCHES AND FASTENED WITH 1- INCH ROUND PLASTIC CAP, METAL CAP NAILS OR NAILS AND TIN- TABS, ATTACHED TO A NAILABLE DECK WITH ONE ROW IN THE FIELD AND OF THE SHEET WITH A MAXIMUM FASTENER SPACING OF 12" O.C. AND ONE ROW AT THE OVERLAPS FASTENED 6- INCHES O.C. AN APPROVED SYNTHETIC UNDERLAYMENT SHALL BE INSTALLED IN ACCORDANCE WITH R708.7 OF THE FBC AND THE MANUFACTURER'S INSTALLATION INSTRUCTION. (NO ADDITIONAL UNDERLAYMENT SHALL BE REQUIRED OVER THE TOP OF THIS SHEET) VALLEY FLASHING: VALLEY LININGS SHALL BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S INSTALLATION INSTRUCTIONS BEFORE APPLYING SHINGLES. VALLEY LININGS OF THE FOLLOWING TYPES SHALL BE PERMITTED. 1.FOR OPEN VALLEY (VALLEY LINING EXPOSED) LINED WITH METAL, THE VALLEY LINING SHALL BE AT LEAST 24" WIDE AND OF ANY OF THE CORROSIAN-RESISTANT METALS IN TABLE R903.1 2.FOR OPEN VALLEYS, VALLEY LINING OF TWO PLIES OF MINERAL SURFACE ROLL ROOFING, COMPLYING WITH ASTM D 249, SHALL BE PERMITTED. THE BOTTOM LAYER SHALL BE 18" AND THE TOP LAYER A MINIMUM OF 36" WIDE. 3.FOR CLOSED VALLEYS (VALLEYS COVERED WITH SHINGLES), VALLEY LINING OF ONE PLY SMOOTH ROLL ROOFING COMPLYING WITH ASTM D 224 TYPE II OR TYPE III AND AT LEAST 36" WIDE OR VALLEY LINING AS DESCRIBED IN ITEMS 1OR 2 ABOVE SHALL BE PERMITTED. SPECIALTY UNDERLYING COMPLYING WITH ASTM D 1970 MAY BE USED IN LIEU OF THE LINING MATERIAL. HIP FLASHING: THE UNDERLAYMENT SHALL BE INSTALLED IN WATER SHEDDING FASHION. AT THE HIP LINE FOLD THE UNDERLAYMENT OVER THE HIP AND MECHANICALLY FASTEN AT 36" O.C. MAXIMUM TO THE OPPOSING SIDE OF THE ROOF. REPEAT PROCEDURE FOR THE OPPOSING SIDE OF THE ROOF. WHEN COMPLETED THERE WILL BE TWO LAYERS OF UNDERLAYMENT OVERLAPPING THE ROOF. By Toni Gindlesperger at 1:09 pm, Apr 29, 2022 1:57 pm, May 10, 2022 8'7'-5 1/4"4'-11 3/4"Truss Shape GARAGE TRUSS DESIGN E14 B3396B18RB27RSB3021B33SB36363DB3036B3612B3612B3312 3DB3036B3612 B1212RB1212RB3312SB3021DWB3312B3612B3612 B3612 B1212RB1212RB3312SB4521 B3634SB3336B3634B3396B18RB27RSB3021B33SB36363DB3036B3612B3612B3312 3DB3036B3612 B1212RB1212RB3312SB3021DWB3312B3612B3612 B3612 B1212RB1212RB3312SB4521 B3634SB3336B3634Double Door Refrigerator 2Refrigerator SpaceGas RangeHVAC Glass Island HoodW423024W1542LW1542LW3042W331824W1518LW1518LW3018W3042W1518LGas Tankless Water HeaterHose BibbHose Bibb Hose Bibb16080 XXXO9080 XXO4020FX 72" AFF4020FX 72" AFF4020FX 72" AFF4020FX 72" AFF4020FX 72" AFF60803060SH 24" AFF (4) 2016FX 72" AFF10070 OHD10070 OHD 3040FX 48" AFF4020SH 72" AFF2880(4) 2016FX 72" AFF(2) 3060FX w/ 3" BETWEEN 24" AFF 288028802880 5080 28802880 3080 28802834 UP Elevation 4E10E10 Elevation 10E14E14 GARAGE TRUSS DESIGN BATH DETAIL16'-5"5'-5"5'-5"4'13'-1"13'-3"15'-6"7'-4"3'5'-6"3'-6"3'-6"5' 3'-4"8'-6"4'-8"5'-10"35' 11"10'-1"6"10'-1"11"12'-6"28'-4"5'-9"7'-11"8'-10 1/2"10'-4"11'-10 1/2"32'-10 1/2"28'-4"73'-1"6'-0 1/2"5'-10"6'-6" 21'7'7'2'-10"2'-6"2'-6"2'-6"12'-2"4' 7'-3"4'-2"5'-8"3'12'-3"10'-9"5' 6'-4"5'-6"2'-5"5'-11"1'-4"7'-9"4'-2"7'-6 1/2" 8' 6'-9" X 5'-3" 11'-0" X 11'-2" 6'-9" X 7'-7" 5'-0" X 5'-0" LIVING AREA SGD Latch side SGD Latch side FRAME WALL 2X6, FIR INSIDE TO DEPTH OF SGD TRACK PANTRY Water Softener Loop Stub gas line and electric circuit for grill provide circuit for Fridge 6" Filler REAR LANAI DINING GREAT ROOM KITCHEN ENTRY STOP N DROP64" x 59 inside dim. MIKE'S BATH 1st Floor Under Roof 2382 sq ft 50 x 130= 6500 x 35%= 2275 BATH OFFICE BOX BEAM 6" WIDE AND 12" DOWN FROM PLATE HEIGHT Opening for Versalift Model 24 Rough Opening 22 1/2"x 46 1/2" Need attachment above to hold 300 lbs ATTIC ACCESS ATTIC STORAGE, SEE GARAGE TRUSS DESIGN DETAIL LOAD BEARING BEAM BOX 5 1/2" WIDE x 12" BELOW PLATE 1st Floor DN SB3921 SB4521SB4521B1821L SB48SB3921 SB4521SB4521B1821L SB48Steel Tub HVAC3060SH 24" AFF3060SH 24" AFF2038SH 52" AFF 9080 XXO 3060FX 24" AFF3060FX 24" AFF2626FX 66" AFF2626FX 66" AFF2626FX 66" AFF2626FX 66" AFF 2626SH 66" AFF 4020SH 72" AFF4020SH 72" AFF4020SH 72" AFF3060SH 24" AFF3060SH 24" AFF28682880 4080288028682668286850683068 28682868 2868 28682868 2868 WDElevation 4E10E10 Elevation 10BATH DETAIL 6'-0 1/2"5'-4"5'-4"3'-4 1/2"2'-4"12'-7"3'-11"3'-11"5'-8"12'7'-4"11'-5"11'-6"5'-10"36'-5"8'-4"3'-3"3'-1"4'-2"4'-7"5'2'-4"2'-6"3'-9"3'-9"2'-7" 7'-3 1/2"4'-3"2'6'-8"7'-4"7'-5 1/2" 13'-6 1/2"21'-5 1/2" 5'-11 1/2"7'-3"4'-1"7'-0 1/2"4'-3"5'-3"5'-3"4'-1"2'-1"6'9'-6"24'-6"10'-6"3'-6"5'3'-6"3'-5"4'-9"3'-3"11'-6"2'3'-4"2'6'-3 1/2"4'10'-4"2'-9"8'-9" X 5'-6" 12'-7" X 6'-7" 12'-1" X 11'-0" 10'-1" X 7'-5" 11'-9" X 10'-7" 5'-6" X 9'-0" 5'-6" X 7'-9" 14'-0" X 18'-0" 5'-3" X 6'-8" 5'-0" X 5'-0" 6'-9" X 11'-0" 6'-5" X 4'-3" LIVING AREA BATH OPEN BELOW BEDROOM #2 BEDROOM #1 LAUNDRY MASTER BDRM CLOSET CLOSET CLOSET CLOSET MASTER BATH SHOWER ROOF OVER ENTRY EXTEND ROOF 1' FROM CORNER OF ENTRY BOX BEAM 6" WIDE AND 15" DOWN FROM TOP PLATE FRAME WALL 54" TALL FROM PORCH FLOOR BOX POST 6"x6" WRAP WITH HARDI TRIM LOAD BEARING BEAM BUILT IN IRONING BOARDPROVIDE NICHE 14 1/2" W X 46 1/2" TSILL AT 27" AFFDecorative Box/ non living space 2nd Floor B3612B3612 SHOWER HEAD GLASS DOOR SHOWER GLASS B3612B3612 BATH DETAIL FINISH ROOFING ROOFING MEMBRANE 7/16" OSB SHEATHING METAL EAVESDRIP 1"X2" P.T. DRIP CONCRETE SLAB TRUSS VINYL SOFFIT ALUMINUM FASCIA WALL INSULATION 1/2" GYPSUM INSULATION POLY SILL SEAL 2"x6" SUBFASCIA MOISTURE BARRIER CEMENTIOUS BOARDAND BATTON SIDING 7/16" OSB SHEATHING COMPACTED FILLEXISTING GRADE CMU 3 BLOCKS EXPOSED (24")REVISION TABLENUMBERDATEREVISED BYDESCRIPTIONSHEET: SCALE:DRAWINGS PROVIDED BY:DATE: 4/28/22 TOTAL ENCLOSED CONDITIONED VOLUME 25980 CUBIC FT ROOF VENT CALCULATION: FOAM INSULATION ALL SOFFITS ARE UNVENTED PROVIDE 2 ROWS OF SOD FOR FOUNDATION STABILIZATION *NO IRRIGATION PROVIDED BY BUILDER*ASHLAR HOME BUILDERS LLC5295 CR 209sGreen Cove Springs, FL 32043LUCERO RESIDENCE376 TENTH STREETATLANTIC BEACH, FL 322331'-4" By Toni Gindlesperger at 1:09 pm, Apr 29, 2022 1:58 pm, May 10, 2022 B3396B18RB27RSB3021B33SB36363DB3036B3612B3612B3312 3DB3036B3612 B1212RB1212RB3312SB3021DWB3312B3612B3612 B3612 B1212RB1212RB3312SB4521 B3634SB3336B3634B3396B18RB27RSB3021B33SB36363DB3036B3612B3612B3312 3DB3036B3612 B1212RB1212RB3312SB3021DWB3312B3612B3612 B3612 B1212RB1212RB3312SB4521 B3634SB3336B3634W423024W1542LW1542LW3042W331824W1518LW1518LW3018W3042W1518LUP R R RR R R R C 4' AFFGFI 4' AFF C GFI GFI GFIGFI GFI GFI GFI R R R R R R R R R R R R R R R 48" LED 48" LED GDO GDO 48" LED 48" LED SD GFI Security Camera 66" AFF C5 CAT5R R R R R RECESS IN SHOWER R R GFI R 2'-6"8'-1"2'-11 1/2"4'-4"2'-2"2'-2"4'-4"2'-6 1/2"2'-6"7'-3 1/2"2'-6"4'-6"4'-11" 11'-1"5'-9"1332 SQ FT LIVING AREA PANTRY Water Softener Loop REAR LANAI DINING GREAT ROOM KITCHEN ENTRY MIKE'S BATH BATH OFFICE SWITCH RECESS IN FOYER ABOVE HVAC 1st Floor DN SB3921 SB4521SB4521B1821L SB48SB3921 SB4521SB4521B1821L SB48WDC5 CAT5R C C C RR R R RR RR R R R R R R R R RR RR 2 WAY R R R R R Provide Iron Circuit3'3'6'-0 1/2"6'-0 1/2"3'1270 SQ FT LIVING AREA BATH OPEN BELOW BEDROOM #2 BEDROOM #1 LAUNDRY MASTER BDRM CLOSET CLOSET CLOSET CLOSET MASTER BATH SHOWER HVAC 2nd Floor WP R 4 GFCI 3WP SD EP DC SD DM A T AV Control C5/TVC5 TV T SP SP DESCRIPTIONSYMBOL ELECTRICAL - DATA - AUDIO LEGEND Ceiling Fan Ventilation Fans: Ceiling Mounted, Wall Mounted Ceiling Mounted Light Fixtures: Surface/Pendant, Recessed, Heat Lamp, Low Voltage Wall Mounted Light Fixtures: Flush Mounted, Wall Sconce Chandelier Light Fixture 240V Receptacle 110V Receptacles: Duplex, Weather Proof, GFCI Switches: Single Pole, Weather Proof, 3-Way, 4-Way Switches: Dimmer, Timer Audio Video: Control Panel, Switch Wall Jacks: CAT5, CAT5 + TV, TV/Cable Telephone Jack Intercom Thermostat Door Chime, Door Bell Button Smoke Detectors: Ceiling Mounted, Wall Mounted Electrical Breaker Panel Speakers: Ceiling Mounted, Wall Mounted Fluorescent Light Fixture REVISION TABLENUMBERDATEREVISED BYDESCRIPTIONSHEET: SCALE:DRAWINGS PROVIDED BY:DATE: 4/28/22ASHLAR HOME BUILDERS LLC5295 CR 209sGreen Cove Springs, FL 32043LUCERO RESIDENCE376 TENTH STREETATLANTIC BEACH, FL 32233By Toni Gindlesperger at 1:09 pm, Apr 29, 2022 1:58 pm, May 10, 2022 S S COMPACTED FILL PORCH SLAB ATTACH (2) 2X 4'S TO BLOCK ATTACH 2X8 OR LARGER TO 2X4'S (ADD KICKERS IF NEEDED) PORCH CMU STEMWALL PORCH SLAB OVERHANG DETAIL 4" CONC SLABREINFORCEDWITH FIBERMESH ON 6 MIL.VAPOR BARRIER11'-8 1/2"5'-0 1/2"2'-8"5'-7 1/2" 31'-3"1'-11"13'11'-7" 12'32'-9"2'-11"2'-10"22'-7"3"19'-4"8'-6"7'-2"15'-4"3'-6"5'-10"19'11"10'-1"6"10'-1"11"12'-6"73'-1" 3'-4"1'21'14'3'-6"7'1330 SQ FT617 SQ FTShower RecessRecess 4" below FFLIVING AREAGARAGEPORCHPORCHA/C PAD OVERHANG IN THESE EDGES SEE PORCH SLAB OVERHANG DETAIL OVERHANG IN THIS EDGE SEE PORCH SLAB OVERHANG DETAIL 1. ALL WORK SHALL BE IN STRICT COMPLIANCE WITH THE 2020 FLORIDA BUILDING CODE, RESIDENTIAL AND COUNTY BUILDING DEPARTMENT 2. STRIP TOPSOIL AND ORGANIC MATTER FROM ALL AREAS WHERE CONSTRUCTION WILL OCCUR 3. FILL SHALL BE FIRMLY COMPACTED, CLEAR SANDY/CLAY MATERIAL FREE OF ROOTS, ORGANIC MATTER AND DEBRIS 4. ALL BEARING FOOTERS TYPE AND LOCATIONS WILL BE COORDINATED WITH STRUCTURAL ENGINEER 5. SHOWER SHALL BE RECESSED MINIMUM 4" WITH THICKENED FOOTER 6. HEIGHT OF SLAB TO BE VERIFIED BY BUILDER FOUNDATION NOTES: Foundation REVISION TABLENUMBERDATEREVISED BYDESCRIPTIONSHEET: SCALE:DRAWINGS PROVIDED BY:DATE: 4/28/22ASHLAR HOME BUILDERS LLC5295 CR 209sGreen Cove Springs, FL 32043LUCERO RESIDENCE376 TENTH STREETATLANTIC BEACH, FL 32233By Toni Gindlesperger at 1:09 pm, Apr 29, 2022 1:58 pm, May 10, 2022