376 10th ST RES21-0373 Metal Sales Siding_1RES21-0373 By Mike Jones at 10:05 am, Jan 20, 2022 FL 14645.11-R4 C2397-11 10.7.2020 Page 2 of 3 Manufacturer: Metal Sales Manufacturing Corporation Product Name: Image II Panel Description: Max. 16" wide coverage with 1" high ribs Materials: Min. 26 ga., 50 ksi steel. Galvanized coated steel (ASTM A653) or Galvalume coated steel (ASTM A792) or painted steel (ASTM A755). Corrosion resistant as per FBC 2020 Section 1507.4.3. Deck Description: Min. 7/16" thick OSB or min. 15/32" thick Plywood or min. ¾" thick wood plank (min SG of 0.42) for new and existing constructions. Designed by others and installed as per FBC 2020. Deck Attachment: 8d x 2.5" long ring shank nails or #8 x 2" long wood screws @ 6" o.c. (Minimum) in the plywood field and edges. Designed as per FBC 2020. New Underlayment: Minimum underlayment as per FBC 2020 Section 1507.4.5.1. Required for new construction and optional for reroofing construction. Existing Underlayment: One layer of asphalt shingles over one layer of #30 felt. For reroofing (Optional) construction only. Slope: 1/2:12 or greater in accordance with FBC 2020 Section 1507.4.2. Requires applied lap sealant for roof slopes less than 3:12. Allowable Uplift Load: 20.8 psf @ fastener spacing of 24" o.c (Factor of Safety = 2) 63.5 psf @ fastener spacing of 6" o.c 86.55 psf @ fastener spacing of 6" o.c with 3/8" bead adhesive in panel sidelap Fastener Pattern: #10 pancake head screws along panel seam. Fasteners are corrosion resistant as per FBC 2020 Section 1507.4.4. Fastener shall be of sufficient length to penetrate through the deck a minimum of ¼". Sidelap Adhesive: Schnee-Morehead SM7108 Permathane adhesive Test Standards: Roof assembly tested in accordance with UL580-94 (Rev 98) ‘Uplift Resistance of Roof Assemblies’ & UL1897-98 ‘Uplift Tests for Roof Covering Systems’. Test Equivalency: The test procedures in UL 580-94 comply with test procedures prescribed in UL 580-06. The test procedures in UL 1897-98 comply with test procedures prescribed in UL 1897-12. FL 14645.11-R4 C2397-11 10.7.2020 Page 3 of 3 Code Compliance: The product described herein has demonstrated compliance with FBC 2020 Section 1507.4. Product Limitations: Design wind loads shall be determined for each project in accordance with FBC 2020 Section 1609 or ASCE 7-16 using allowable stress design. The maximum fastener spacing listed herein shall not be exceeded. The design pressure for reduced fastener spacing may be computed using rational analysis prepared by a Florida Professional Engineer or based on Metal Sales load span table. This evaluation report is not applicable in High Velocity Hurricane Zone. Fire classification is not within scope of this Evaluation Report. Refer to FBC 2020 Section 1505 and current approved roofing materials directory or ASTM E108/UL790 report from an accredited laboratory for fire ratings of this product. Supporting Documents: UL580/UL1897 Test Reports Farabaugh Engineering and Testing Inc. Project No. T176-11, Reporting Date 4/26/11 Project No. T260-11, Reporting Date 8/15/11 MINIMUM SPACING DISTANCE FOR ALLOWABLE UPLIFT. MJ 1.20.2022