376 10th ST RES21-0373 Truss LAYOUTT02
T03
T03
T03
T06
T07
T08
T09
T10
T11
T17
T18
T19
T20
T10
T11
T12 T13T14
T15HJ01HJ01EJ01EJ01CJ01CJ02CJ03CJ01
CJ02
CJ03EJ01EJ01CJ01CJ02CJ03CJ01
CJ02
CJ03 EJ01T16
T16
T16HJ01CJ01CJ02CJ03CJ01
CJ02
CJ03 EJ01T01T04
T04
T05 HJ01CJ01CJ02CJ03CJ01
CJ02
CJ03
EJ01EJ01EJ01EJ01EJ0112-00-007-00-0010-00-007-00-0010-00-001-00-00 7-00-006-00-001-06-00
24-05-08 10-05-08 5-09-0836-05-008-03-0821-05-0813-05-08
34-11-00
8-03-0822-10-087-04-0811-11-0850-06-004-00-00
CONV FRAME
SHIFT F14 & F15FOR PLUMBINGWHERE NEEDED
LIGHT ATTICSTORAGE SPACE
ALL FIRST FLOOR EXTERIOR WALLS AND ANY 2ND FLOOR OR INTERIOR WALLS THAT ALIGNWITH THEM HAVE BEEN HELD IN 1/2" FOR SHEATHING
USE SIMPSON HTU26 FOR TYPICAL SINGLE PLY TRUSS CONNECTIONS UNLESS NOTED OTHERWISETF01 = SIMPSON HHUS26-2
TF02 = SIMPSON HGUS28-2F10, F11, F12 = SIMPSON HHUS48
F05, F08, F09 = SIMPSON THA422LGR BM1
F14 F15
FKW1FKW7F10F10F11 F11F11F11F12F12F13F13F13F13F13F13F13F13F13FKW8FKW5
FKW4
FKW3
F01
F01
F01
F01
F01
F03
F03
F06
F04
FKW2
F07
F07
FKW6
F09F08F05
F02
FS1 FS1 FS1 FS1 FS1 FS1 FS1 FS1 FS1
T24
T25
T26HJ02HJ02
EJ02EJ02EJ02CJ04CJ05CJ06CJ04
CJ05
CJ06
EJ02EJ02EJ02CJ04CJ05CJ06CJ04
CJ05
CJ06
T27
T27
T28
T28
T29
T30
T30
T30
EJ03
EJ03
EJ03
EJ03
T21
T22
T22
T23
TF08
TF07 T31T32T32T32HJ01CJ01
CJ02
CJ03 CJ01CJ02CJ03EJ01
TF02TF04 TF01
TF06
TF05
TF03
TF03
TF03
4-00-00 8-06-00 22-05-00 28-03-0832-10-003-07-00 8-03-08
21-00-0013-11-00
8-03-0822-10-0873-00-0034-11-00
9-00-00
2-00-00
2-00-00
1-06-00
6-00-007-00-0020-00-001-08-0012-00-00 20-00-00
10-05-087-04-0811-11-087-00-0015-06-007-00-00 6-00-00
4-00-001-02-004-00-001-04-00
:- Per ANSI/TPI 1-2002 all " Truss to Wall"
connections are the responsibility of the BuildingDesigner, not the Truss Manufacturer.- Use Manufacturer's specifications for all hangerconnections unless noted otherwise.- Trusses are to be 24" o.c. U.N.O.
- All hangers are to be Simpson or equivalent U.N.O.-Use 10d x 1 1/2" Nails in hanger connections to single
ply girder trusses.- Trusses are not designed to support brick U.N.O.- Dimensions are Feet-Inches- Sixteenths
PHONE: 850-835-4541FAX: 850-835-4532
PHONE: 904-772-6100
FAX: 904-772-1973
PHONE: 813-621-9831FAX: 813-628-8956
10' 1-1/8"
9' 1-1/8"
21' 9"
.
HATCH LEGEND
.
Floor 1 Job #:Floor 2 Job #:
Model:
Builder:
Roof Job #:
ASHLAR HOME BUILDERS
376 10TH ST.
Drawn By:
CUSTOM
Legal Address:
8/16/21 GP
Date:
2817017
2905744 .2817017
Original Ref #:
No back charges will be accepted by BuildersFirstSource unless approved in writing first.
ACQ lumber is corrosive to truss plates. Any ACQlumber that comes in contact with truss plates (i.e.scabbed on tails) must have an approved barrier appliedfirst.
Refer to BCSI-B1 Summary Sheet-Guide for handling,Installing and Bracing of Metal Plate Connected WoodTruss prior to and during truss installation.
It is the responsibility of the Contractor to ensure of theproper orientation of the truss placement plans as tothe construction documents and field conditions of thestructure orientation. If a reversed or flipped layout isrequired, it will be supplied at no extra cost by Builders
FirstSource.
It is the responsibility of the Contractor to make surethe placement of trusses are adjusted for plumbingdrops, can lights, ect..., so the trusses do not interfere
with these type of items.
All common framed roof or floor systems must be
designed as to NOT impose any loads on the floortrusses below. The floor trusses have not been designedto carry any additional loads from above.
This truss placement plan was not created by an
engineer, but rather by the Builders FirstSource staffand is solely to be used as an installation guide and
does not require a seal. Complete truss engineering andanalysis can be found on the truss design drawingswhich may be sealed by the truss design engineer.
Gable end trusses require continuous bottom chord
bearing. Refer to local codes for wall framingrequirements.
Although all attempts have been made to do so, trussesmay not be designed symmetrically. Please refer to theindividual truss drawings and truss placement plans forproper orientation and placement.
FirstSourceBuilders
This Truss Engineering package
has been reviewed and
complies with the design
intent applied to this project.
SHOP DRAWING
APPROVAL STAMP
MURRAY
ENGINEERING INCORPORATED
157 HAMPTON PT DRIVE, STE. 3
ST. AUGUSTINE - FL - 32092
C.O.A. #26894 - (904) 342-8751