Loading...
1731 SEMINOLE RD ROW22-0028 COAB Permit Form with ConditionsOWNER:ADDRESS:CITY:STATE:ZIP: LAURIN SUZANNE R 10378 6TH CT NW CORAL SPRINGS FL 33071 COMPANY:ADDRESS:CITY:STATE:ZIP: JEA 21 WEST CHURCH ST JACKSONVILLE FL 32202 TYPE OF CONSTRUCTION: REAL ESTATE NUMBER:ZONING:BUILDING USE GROUP:SUBDIVISION: 169642 0000 OCEAN GROVE UNIT 02 JOB ADDRESS:PERMIT TYPE:DESCRIPTION: VALUE OF WORK: 1731 SEMINOLE RD RIGHT OF WAY SINGLE OR TWO FAMILY RIGHT OF WAY JEA - UNDERGROUND BORE $0.00 LIST OF CONDITIONS Roll off container company must be on City approved list . Container cannot be placed on City right-of-way. 1 PUBLIC UTILITIES UNDERGROUND WATER SEWER UTILITIES INFORMATIONAL Notes: Avoid damage to underground water and sewer utilities. Verify vertical and horizontal location of utilities. Hand dig if necessary. If field coordination is needed, call 247-5878. Any digging requires calling 811 to have ALL public utilities located. 2 PUBLIC WORKS EROSION CONTROL INSTALLATION INFORMATIONAL Notes: Full erosion control measures must be installed and approved prior to beginning any earth disturbing activities. Contact the Inspection Line (904-247- 5814) to request an Erosion and Sediment Control Inspection prior to start of construction. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION. ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES . ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY. 1 of 2Issued Date: 7/7/2022 PERMIT NUMBER ROW22-0028 ISSUED: 7/7/2022 EXPIRES: 10/5/2022 RIGHT OF WAY PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 FEES DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT TOTAL: 3 PUBLIC WORKS ON SITE RUNOFF INFORMATIONAL Notes: All runoff must remain on-site during construction. 4 PUBLIC WORKS ROLL OFF CONTAINER INFORMATIONAL Notes: Roll off container company must be on City approved list. Approved list can be obtained at the Building Department at City Hall. Roll off container cannot be placed on City right-of-way. 5 PUBLIC WORKS RIGHT OF WAY RESTORATION INFORMATIONAL Notes: Full right-of-way restoration, including sod, is required. 6 PUBLIC WORKS UTILITY ROAD CUT INFORMATIONAL Notes: Any utility cuts in the road must be repaired using COJ Standard Detail Case X and must be overlaid 10 feet in each direction from the center of the cut. Repair must be shown on the plans.\r\r\r\r\r\r 7 PUBLIC WORKS RUNOFF INFORMATIONAL Notes: All runoff must remain on-site. Cannot raise lot elevation. 8 PUBLIC WORKS GRASS INFORMATIONAL Notes: Full site to be grassed. 9 PUBLIC WORKS REVISION INFORMATIONAL Notes: Any plan change must be submitted as a Revision to the Building Department. 10 PUBLIC WORKS INFRASTRUCTURE INFORMATIONAL Notes: Any damage done to infrastructure must be repaired by Contractor. 11 PUBLIC WORKS DEBRIS REMOVED INFORMATIONAL Notes: All construction debris must be removed from job site by Contractor. 2 of 2Issued Date: 7/7/2022 PERMIT NUMBER ROW22-0028 ISSUED: 7/7/2022 EXPIRES: 10/5/2022 RIGHT OF WAY PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 H:\Applications & Forms\Word Documents\201801001 Right-of-Way Easement Permit Application.docx Revision Date: 10/1/18 **ALL INFORMATION HIGHLIGHTED IN GRAY IS REQUIRED. RIGHT-OF-WAY / EASEMENT PERMIT APPLICATION City of Atlantic Beach 800 Seminole Road, Atlantic Beach, FL 32233 PERMITTEE RESPONSIBLE FOR NOTIFYING 811 AND OBTAINING UTILITY LOCATES Job Address_________________________________________________ Permit Number________________________ Contractor Information Company______________________________________________ Qualifying Agent_____________________________ Address______________________________________ City________________________ State______ Zip___________ Phone________________________________________ Email_______________________________________________ State Certification/Registration #_______________________________________________________________________ Architect_____________________________________ Phone____________________ Email______________________ Engineer_____________________________________ Phone____________________ Email_______________________ Workers Compensation Insurer ____________________________________ OR Exempt □ Expiration Date __________  Permittee declares that prior to filing this application they have ascertained the location of all existing utilities, both aerial and underground and the accurate locations are shown on the sketches.  Whenever necessary for the construction, repair, improvement, maintenance, safe and efficient operation, alteration or relocation of all, or any portion of said street or easement as determined by the Public Works Director, any or all said poles, wires, pipes, cables or other facilities and appurtenances authorized hereunder, shall be immediately removed from said street or easement or reset or relocated hereon as required by the Public Works Director and at the expense of the Permittee unless reimbursement is authorized.  All work shall meet City of Atlantic Beach or Florida Department of Transportation Standards and be performed under the supervision of ____________________________________________________________________ (Project Superintendent) with (Company Name) ________________________________________________Phone_____________________________  All materials and equipment shall be subject to inspection by the Public Works Director.  All city property shall be restored to its original condition as far as practical, in keeping with City specifications and the manner satisfactory to the City.  A sketch of plans covering details of this installation, as well as a copy of a recent survey shall be made a part of this permit. Calculations showing any increase in impervious area on owner’s lot or in the City right-of-way are to be included with this application.  The permittee shall commence actual construction in good faith within _______ days. If the beginning date is more than 60 days from date of permit approval then permittee must review the permit with the Public Works Director to make sure no changes have occurred in the area that would affect the permitted construction.  It is understood and agreed that the rights and privileges herein set out are granted only to the extent of the City’s right, title and interest in the land to be entered upon and used by the holder, and the holder will, at all times, assume all risk of and indemnify, defend and save harmless the City of Atlantic Beach from and against any and all loss, damage and cost of expenses arising in any manner of the exercise or attempted exercises by the holder of the aforesaid rights and privileges.  The Public Works Director shall be notified 24 hours prior to starting work and again immediately upon completion. _______________________________________________________________________________ Date________________________ Permittee (signed in presence of Notary Public) STATE OF FLORIDA, COUNTY OF DUVAL The foregoing instrument was acknowledged this ___________ day of ________________________________________, 20 _________, by _______________________________________________________________________, who personally appeared before me and (printed name of Permittee) acknowledged that he/she signed the instrument voluntarily for the purpose expressed in it. __________________________________________________________ [ ] Personally Known Signature of Notary Public, State of Florida [ ] Produced Identification (Type) _______________________ 1731 SEMINOLE RD ROW22-0028 JEA 21 WEST CHURCH ST JACKSONVILLE FL 32233 JASON CONNER (904) 568-4281 CONNJJ@JEA.COM JAMES UMSTATTD JEA (904) 665-6125 30 4 MIN 42"**************************** * DRAWING NOT TO SCALE * **************************** ******************************************************************** requirements prescribed in Section 471 Florida Statutes. of the UAO and are exempt from the signing and sealing The plans were prepared by a regular full-time employee ******************************************************************** PHONE NO: ENGINEER: DISTRIBUTION ENGINEERING SCHEMATIC PERMIT JASON CONNER 665-8682 8 DEG ANGLE- EXIT 8 DEG ANGLE- ENTRY STA.1 ENTRY PIT STA.2 EXIT PIT BORE PROFILE OF DIRECTIONAL MAX 16" REAMER 4-6" HDPE DIRECTIONAL BORE ROW22-0028 171175 173176-2 17231735PV 1730174017486116 717117371743 173665 62 62-1 563201741 501746 59 76 172168 311 721729 671742 631721173864-PS90 17TH ST SEMINOLE RDOCEAN GROVE DR17TH ST 2-4CU 2/0P 4/ 0 P4/0P1/0T 2/0P2/0P2/0P 1/0T 30T 1713ABC-VABC-V50A 50A 1673 1745 50A 1733 401731 50B 1703 50C 50B64 50A 1721 50B******************************************************************** requirements prescribed in Section 471 Florida Statutes. of the UAO and are exempt from the signing and sealing The plans were prepared by a regular full-time employee ******************************************************************** UNDERGROUND LEGEND THREE PHASE PADMOUNTED TRANSFORMER SINGLE PHASE PADMOUNTED TRANSFORMER STREET LIGHT EQUIPMENT ADDRESS STATION NUMBER SECONDARY SERVICE PEDESTAL NORMALLY OPEN POINT NEW ELECTRONIC MARKER EXISTING ELECTRONIC MARKER A H P NO TWO PHASE PADMOUNTED TRANSFORMER - OPEN DELTA 6' x 12' CONCRETE MANHOLE 4' x 6' CONCRETE MANHOLE PVC MANHOLEPVC SECONDARY HAND HOLE OR PULL BOX EXISTING CONCRETE CABLE RISER POLE EXISTING WOOD CABLE RISER POLE EXISTING SECONDARY CONDUIT NEW SECONDARY CONDUIT AS INDICATED EXISTING PRIMARY CONDUIT NEW PRIMARY CONDUIT AS INDICATED FUSE - SIZE AND TYPE AS INDICATED UNDERGROUND RISER, SECONDARY OR PRIMARY LIGHTNING ARRESTER CABINET "FF" OR "SF" FAULT FITER CABINET "F" FUSE CABINET "S" SWITCH CABINET, AREA LIGHT EXISTING DIRECT BURIED PRIMARY P NEW SECONDARY R OVERHEAD LEGEND NEW PRIMARY EXISTING PRIMARY EXISTING SECONDARY SPAN GUY NEW WOOD POLE-SIZE AND CLASS AS INDICATED NEW CONCRETE POLE-SIZE AND CLASS AS INDICATED EXISTING CONCRETE POLE EXISTING WOOD POLE REMOVE POLE DOWN GUY HANG OR INSTALL EXISTING REMOVE CIRCUIT NUMBER STATION OR POLE NUMBER TRANSFORMER NUMBER 25KV TRANSFORMER-SIZE AND PHASE AS INDICATED 25KV TRANSFORMER BANK-SIZE AND PHASE AS INDICATED 13.2KV TRANSFORMER-SIZE AND PHASE AS INDICATED 13.2KV TRANSFORMER BANK-SIZE AND PHASE AS INDICATED NEW SERVICE DROP-SIZE AND TYPE AS INDICATED 4KV TRANSFORMER-SIZE AND PHASE AS INDICATED 4KV TRANSFORMER BANK-SIZE AND PHASE AS INDICATED REGULATED OUTPUT-STREET LIGHT TRANSFORMER RECLOSER-TYPE AND NUMBER AS INDICATED SECTIONALIZER-NUMBER AS INDICATED CAPACITOR-NUMBER AS INDICATED VOLTAGE REGULATOR SWITCH-OPEN-TYPE AND NUMBER AS INDICATED SWITCH-CLOSE-TYPE AND NUMBER AS INDICATED FUSE-SIZE AND TYPE AS INDICATED H E TYPE AS INDICATED CONDUCTOR SIZES AND RO R EXISTING SERVICE DROP-SIZE AND TYPE AS INDICATED UNDERGROUND SERVICE-OVERHEAD SOURCE STREET LIGHT-TYPE AS INDICATED LIGHTNING ARRESTER ( IN FEET ) 60 30 60 120 2400 1 inch = ft. 60 JACKSONVILLE, FLORIDA 32202-3139 21 WEST CHURCH ST PHONE NO. ADDRESS COMPANY NAME DATE ELECTRIC UTILITY CONDUIT SYSTEM AUTHORIZED NAME AUTHORIZED SIGNATURE CONTRACTOR'S LICENSSE No. JEA CONTRACT ADMIN: E N G I N E E R I N G R E C O R D CONSTRUCTION : APPROVED FOR DATEBY DESIGNED : CHECKED : APPROVED : NEPTUNE PRIMARY VOLTAGE 565 16 26.4 @jea.comCONNJJ SUBSTATION NAME CIRCUIT NUMBER/S SWITCH MAP NUMBER/S ENGINEER/PROJECT MANAGER JASON CONNER (904)665-8682 (904)568-4281 ENGINEER : PHONE : CELL : EMAIL : EMAIL : AS - BUILT JEA SPECIFICATIONS. VERTICAL FIELD LOCATIONS AND THAT THE MATERIALS USED ARE IN ACCORDANCE WITH THE APPROVED I HEARBY CERTIFY THAT THIS "AS - BUILT" DRAWING REPRESENTS THE ACTUAL HORIZONTAL AND 1 1 OPN : MWO : 8007255 30821578 DRAWING NO. : SHEET NO. OF SUBSTATION/CIRCUIT _1_ _1731_ _2_ _1731_ 3. CREWS MUST ADHERE TO MOT. CABLE IN CONDUIT. 2. BORE SHALL BE AT A MINUMUN DEPTH OF 42". PULL 2/0T (STATION 1)TO DWELLING AT 1731 SEMINOLE RD (STATION 2). 1. DIRECTIONAL BORE 1 - 3"HDPE FROM RISER POLE 1731 ROW22-0028