Loading...
465 BEACH AVE ROOF22-0035 COAB Permit Form with ConditionsFinal Plumbing Final Electrical Final HVAC CC Final Final Building* Swimming Pool Steel Swimming Pool Safety Electrical Grounding & Bonding Swimming Pool Final (Bldg) Swimming Pool Final (PW) Formed Columns/ Beams* Masonry Cell Fill Structural Steel* OTHER: OTHER: OTHER: OTHER: OTHER: Power Pole Silt Fence Piers/ Stem Walls Underground Plumbing Underground Electric Foundation/ Footing Slab** Retaining Wall Footing Driveway Sewer (Building Dept) Sewer Tap (Utilities Dept) Rough Electric* Rough Plumbing/ Top Out* Rough Mechanical* House Wrap Wall Sheathing Roof Sheathing Tie-down Framing Connections Rough Framing Roofing In Progress Window/Door In-Progress Insulation Ceiling Insulation Wall Exterior Lath Stucco Scratch Coat Exterior Siding In-Progress Brick Flashing & Ties Early Power Gas Rough Gas Final* * When all rough electric, plumbing, mechanical are complete but before any work is covered up. * When all gas piping is complete and wallboard is installed but before gas is attached to any appliance. All outlets must be capped and pipe pressurized at a minimum of 15 lbs. * For new living space: When all construction work including electrical, plumbing, mechanical, exterior finish, grading, required paving and landscaping is complete and the building is ready for occupancy, but before being occupied Additional inspections may apply to your project if your project contains these elements: INSPECTIONS REQUIRED FOR BUILDING PERMITS To verify compliance with building codes, inspections of the work authorized are required at various points of the construction. The following inspections are typically required for residential projects: Date: Initial: Date: Initial: _____________________________________________________ Permit Type ____________________________________________________ Permit No. __________________________________________________________ Job Address ____________________________________________________ Contractor POST THIS CARD WITH PERMITS AND PERMIT DOCUMENTATION IN FRONT OF BUILDING Construction Hours per City Code: 7am—7pm Weekdays; 9am—7pm Weekends Building Department Public Works/Utilities Fire Department Phone: 904-247-5826 Phone: 904-247-5834 Phone: 904-630-4789 Fax: 904-247-5845 Fax: 904-247-5843 Fax: 904-630-4203 * When forms and reinforcing steel, anchor bolts, sleeves and inserts, and all electrical, plumbing and mechanical work is in place, but before concrete is poured. * When all structural steel members are in place and all connections are complete, but before such work is covered or concealed. ** FORM BOARD ELEVATION CERTIFICATE MUST BE ON-SITE FOR SLAB INSPECTION METAL ROOF ON BATTONS & MOD BIT ROOF22-0035 465 BEACH AVE THOMPSON ROOFING & RECONSTRUCTION OWNER:ADDRESS:CITY:STATE:ZIP: WILLIAMS JOSEPH NEEL 465 BEACH AVE ATLANTIC BEACH FL 32233 COMPANY:ADDRESS:CITY:STATE:ZIP: THOMPSON ROOFING & RECONSTRUCTION 4791 BLUE MAJOR DR WINDERMERE FL 34786 TYPE OF CONSTRUCTION: REAL ESTATE NUMBER:ZONING:BUILDING USE GROUP:SUBDIVISION: 170159 0000 ATLANTIC BEACH JOB ADDRESS:PERMIT TYPE:DESCRIPTION: VALUE OF WORK: 465 BEACH AVE ROOF NON SHINGLE METAL ROOF ON BATTONS & MOD. BIT $157000.00 FEES DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT BLDG 2ND PLAN REVIEW FEE 455-0000-322-1006 0 $50.00 BUILDING PERMIT 455-0000-322-1000 0 $651.00 BUILDING PLAN CHECK 455-0000-322-1001 0 $325.50 STATE DBPR SURCHARGE 455-0000-208-0700 0 $15.40 STATE DCA SURCHARGE 455-0000-208-0600 0 $10.27 LIST OF CONDITIONS Roll off container company must be on City approved list . Container cannot be placed on City right-of-way. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION. ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES . ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY. 1 of 2Issued Date: 7/11/2022 PERMIT NUMBER ROOF22-0035 ISSUED: 7/11/2022 EXPIRES: 1/7/2023 ROOF NON SHINGLE PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 TOTAL: $1,052.17 2 of 2Issued Date: 7/11/2022 PERMIT NUMBER ROOF22-0035 ISSUED: 7/11/2022 EXPIRES: 1/7/2023 ROOF NON SHINGLE PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 ROOF22-0035 By Mike Jones at 1:30 pm, Jun 17, 2022 REVIEWED FOR CODE COMPLIANCE JOB COPY Building Permit Application City of Atlantic Beach Building Department REVIEWED 800 Seminole Road, Atlantic Beach, FL 32233 *ALL INF-ORIVIATION y ----:--------r-----,....,.,......nn.....,,.,....----✓ Phone: (904) 247-5826 Email: Bu ilding-Dept@coab.us Job Address: ~lc:i5 ~ac.b.. ~U. .cl.ilao\J ~C}) Permit Number: __ _ Legal Description ; _J:; ~:;; -;C\; Ji.kn-he ~ l~rr:Y 5 ~h 112:t RE# ~'':--'1'--i"'-...._ ......... -__,___.._~_ I '5 ~)~ ~I Valuation of Work (Replacement Cost)$ \':)J (Y)D -Heated/Cooled SF _____ Non-Heate /Cooled _____ _ ~e..~· • Class of Work: □New □Addition RJ'Alteration □Repair □Move □Demo □Pool □Windo /Door • Use of existing/proposed structure(s): □Commercial ~esidential • If an existing structure, is a fire sprinkler system installed?: □Yes ~o 0 Describe in detail the type of work to be performed. ~d ~Ca>..--k-d S\Lt-1 l>f'I 't&~~ .~\ !/"\~ TLL lh!W w•Ju ~<N~ ~ Florida Product Approval # ___ L.l,,o"----.1....1.<LJ-iJ ....... "-------'-'!-¥A-4L'~..i---1,'.J..l...L!..l'- Property Owner Information ~i~;~~~\ -\ ' m 45 E-Ma:iF ____ ~.,_,,.L.LJ,~--->.orp,,<,1.......,_....,_.....,..._-'-+-------------''--t......,c.a::..,,,,__+--------- Owner or Agent (If Agent, Contractor Information Name of Company ~~~C~ cl-iDr)Qualifying Agent Address Y:191 ~~-City )1J\l\ritcO'lecf Office Phone :5:53=3iq ....gi y /) Job Site Contact Number _______________ _ State Certification/Registration# Ccc J33~:;)...[\;l E-Mail--1-.L..4'U. . .L.L.. ..................... ~-"'~"'"""--...................................... ..L.L.. ___ _ Architect Name & Phone#_-+>....__,.,___ ______________________ -+--------- Engineer's Name & Phone# _ _..,,£.Jl.___ ______________________ 1-----,---,------- Workers Compensation Insurer _______________ OR Exempt pi( Expiration Da e a"j':\ L::i.u;> 3 Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that n work or ihstal lation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of II the laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WOR , PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, and AIR CONDITIONERS, etc. NOTICE: In addition t the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public rec rds of this county, and there may be additional permits required from other governmental entities such as water management di ricts, state agencies, or federal agencies. OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done i compliance with all applicable laws regulating construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMEN EMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPER . IF YOU INTEND s,ned and sworn to (or affirmed) befo::::is ii;_ dt .J 1..1 Q(. , ,,;2Q,1;;2 , by ~ Q ~~";z)O • ~Oi- ~\ c, UJ.o~u~ (Signature of Notary) Si\ned and sworn to ( · day of ...__u "" , QC);l. (Signat re of Notary) ~"~:.~~'<,,.., JANICE WILLIS ~Personally Known OR • ,.W, " Commission# GG 316008 I ] Produced Identification 1~~.., Expires July 23, 2023 Type of Identification: ____ 0_,_,\ __ •_0(IG_•_d _1hnJ_&u_dlJ_"'_No_i._rv_s_,,..,..._ JANICE WILLIS • Commission :I GG 316006 ~ Personally Known OR Expires Jul~ 23, 2023 [ ] Produced Identification Bonded lhru 8u.« Nou,ry Serva. Type of Identification:------+-------- Doc# 2022146105, OR BK 20303 Recorded 05/31/2022 03:55 PM, RECORDING $10.00 Page 1905, Number Pages: 1, JODY PHILLIPS CLERK CIRCUIT COURT DUVAL COUNTY JOB COPY NOTICE OF COMMENCEMENT State of _F_lo_rid_a ___________ _ Tax Folio No . _1_1_0_15_9_-0_0_0_01------------·- County of _D_u_v_a1 __________ _ To Whom It May Concern: The undersigned hereby informs you that improvements will be made to certain real property, and in a1 cordance with Section 713 of the Florida Statutes, the following information is stated in this NOTICE OF COMMENCEMENT. Legal Description of property being improved: 5-69 16-2S-29E ATLANTIC BEACH LOT 4, S1/2 LOT 5 BLK 21 Address of property being improved: _4_6_5_B_EA_C_H_A_VE_A_11a_n_1ic_B_e_a_ch_F_L _32_2_3_3 ____________ +----------- General description of improvements: _R_e_-_R_o_o_f _____________________ +---------·- Owner. -~D __ \.,..Dc,,,,.:._,\~\\.LL~ .... a._._m._._s.,__ ____ _ Address: 465 BEACH AVE Atlantic Beach FL 3223 Owner's interest in site of the improvement; _o_w_n_e'---------------------+----------·-- Fee Simple Titleholder (if other than owner):-----------------------+-----------·- Name: ---------------------------------1-------------- Contractor: Thompson Roofing & Reconst_ru_c __ tio_n ____________________________ -1---------- Address: 4791 Blue Major Dr Windermere Fl 34786 Telephone No.: _;_(5_7_3;_)7_8_9-8_36_7 _____ _ Fax No: ____________ _ Surety (if any) ________________________________ +---------- Address: __________________________ Amount of Bond$_---------·--- Telephone No: ______ _ Fax No:----------···-----·-·-- Name and address of any person making a loan for the construction of the improvements Name:---------------------------------+----------- Address: ------------------------------.. -·--+------------ Phone No: ----· -~----------·-----Fax No: ____________ _ Name of person within the State of Florida, other than himself, designated by owner upon whom notices I r other documents may be served: Name: ----------------------------------1------------ Address: -----------------------------------------+---------- Telephone No:------------·-__ Fa x No: _______________ .. ___ _ In addition to himseif, owner designates the following person to receive a copy of the Lienor's Notite as provided in Section 713.06(2) (b), Florida Statues. (Fill in at Owner's option} Name:-------------------------·---------------+----------- Address: --------------------------------------+--------- Telephone No: ___________ _ Fax No : _______________ _ Expiration date of Notice of Commencement (the expiration date is one (1) year from the date of recording unless a different date is specified): -------------------------------...,....,,-,-----.hrtrt:"U!IIT-n"Cc--------~~v ~//#( J.~rm,t: VVII.LI-> THIS SPACE FOR RECORDER'S USE ONLY .,~,. Commssion#GG316008 OWNER · .,. • Signed: ,,.-·-·y\ ,r\ / %~,,,~~<-" len~~~i~::;;~~t~'tl-~:} Before me this __ Q_1,_i&J.. .. day of rn-•A """;l ir, the County of Duval, State Of Florida, has personally appeared ~ r-Y> ,..., l_" h 1\ 'io..,rn5 . Notilry Public at large, State of Florida, Count~f Du :CJ <n ,......·, ~ My commission expires: '7\ ~=,) ~~--.. )"'-' 1 _ .... ___ _ Personally Known: _________ .... ------'-------------or Produ ced Identification:-~ L.. 'h.....,._./__.. _____ --+---------...... JOB COPY OWNER'S AUTHORIZATION FOR AGENT City of Atlantic Beach Community Development Department 800 Seminole Road Atlantic Beach, FL 32233 (P) 904-247-5800 OWNER INFORMATION NAME Margo Williams ADDRESS 465 Beach Ave CITY Atlantic Beach AGENT INFORMATION NAME John Thompson I Thompson Roofing & Reconstruction ADDRESS 4791 Blue Major Dr CITY Windermere STATE Fl STATE FL PHONE# 229-201 -4166 CELL# ZIP CODE 32233 PHONE # 573-789·8367 CELL # ZIP CODE 34786 _j K.l"u-..nc::..-:-........ is hereby authorized to act on behalf of IT'o~ '1 ..,\a:x,~ U.J i\\ :ams the owner(s) of tho elands described within the attached application and as described i~ e attached i::leed or other such proof of ownership as may be required, in applying to the City of Atlantic Beach, Florida, for an application related to a Development Permit or other action pursuant to: [8] BUILDING PERMIT □ TREE PERMIT 0 SIGN PERMIT □ USE-BY-EXCEPTION 0 ZONING VARIANCE 0 ZONING MAP AMENDMENT 0 COMPREHENSIVE PLAN AMENDMENT □ PLAT, REPLAT OR LOT DIVISION 0 OTHER I HEREBY CERTIFY THAT ALL INFORMATION PROVIDED IS CORRECT: Signature of Property Owner(s) or Authorized Agent Margo Williams 6/6/2022 PRINT OR TYPE NAME DATE DATE Signed and sworn before me on this "=-1,. day of__,,..,.._~,µ1..a.1.._auf ____ ~ .;2.QO.;l by State of_~~L~----- County of h1, lo I r:n,,c-30 "'-Jo'.:¥!p:> U.A)\: o..m S Identification verified: ~ L b L ::> Oath Sworn: 0 Yes 11 OWNERS AUTHORIZATION 03.01.2018 JANICEWILLIS /~,..,n'--'--'·,_,_~"""'----""--""'-==""""------------ Commlss\on # GG 31600~gnature Expires July 23, 2023 llondtdThluBudgetl'llllllY 511'11o11My Commission expires I I ;2 3 I ;lQ:;) 3 Page 1 of 4 Updated 06/21/21 PRODUCT APPROVAL INFORMATION SHEET FOR THE CITY OF ATLANTIC BEACH, FLORIDA (*REQUIRED) *Project Address: _________________________________________________________________________ Permit #: ___________________________ *Owner/Project Name: _______________________________________________________________________________________________________ As required by Florida Statute 553.842 and Florida Administrative Code Rule 61G20-3, please provide the information and product approval number(s) for the building components listed below as applicable to the building construction project for the permit number listed above. You should contact your product supplier if you do not know the product approval number for any of the applicable listed products. Information regarding statewide product approval may be obtained at: www.floridabuilding.org. Category/Subcategory Manufacturer Product Description Limitation of Use State # Local # A. EXTERIOR DOORS 1. Swinging 2. Sliding 3. Sectional 4. Garage Roll-Up 5. Automatic 6. Other B. WINDOWS 1. Single hung 2. Horizontal slider 3. Casement 4. Double hung 5. Fixed 6. Awning 7. Pass-through 8. Projected 9. Mullion 10. Wind breaker 11. Dual action 12. Other ROOF22-0005 By Mike Jones at 1:33 pm, Jun 17, 2022JOB COPY [ __ R_E11i_1E_Wi_Eo _____ ] 465 Beach Ave Atlantic Beach Fl Margo Williams NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA Page 2 of 4 Updated 06/21/21 Category/Subcategory Manufacturer Product Description Limitation of Use State # Local # C. PANEL WALL 1. Siding 2. Soffits 3. EIFS 4. Storefronts 5. Curtain walls 6. Wall louvers 7. Glass block 8. Membrane 9. Greenhouse 10. Synthetic stucco 11. Other D. ROOFING PRODUCTS 1. Asphalt shingles 2. Underlayments 3. Roofing fasteners 4. Nonstructural metal roof 5. Built-up roofing 6. Modified bitumen 7. Single ply roofing 8. Roofing tiles 9. Roofing insulation 10. Waterproofing 11. Wood shingles/shakes 12. Roofing slate 13. Liquid applied roofing 14. Cement-adhesive coats 15. Roof tile adhesive 16. Spray applied polyurethane roof 17. Other JOB COPY NA NA NA NA NA NA NA NA NA NA NA NA PolyGlass PolyGlass TU MAX FL5259.1 8 D Ring Shank Roser Stone Coated Steel FL 17411.1 NA PolyGlass Base & Cap Sheet 17-1004.09 17-1004.09 NA NA NA PolyGlass TU MAX FL5259.1 NA NA NA NA NA NA JOB COPY In addition to completing the above list of manufacturers, product description and State approval number for the pro ucts used on this project, the Contractor shall maintain on the job site and available to the Inspector, a legible copy of each manufacturer's printed specifications and installation instructions along with this Product Approval Sheet. I certify that this product approval list is true and correct to the best of my knowledge. I further certify that use of differe t components other than the ones listed in this document must be approved by the Building Official. *Contractor Name (Print Name): John Thompson *Contractor Signature: ____ ..q....-'-------4--'-·-'-d.:,_:_;::__-.4-....:;_;::__ __ *Company Name: Thompson Roofing & reconstruction *MailingAddress: 4791 Blue Major Dr *city: Windermere *State: Fl *Zip Code: _3_4_7 __ 6 _______ _ *Telephone Number: 573-789-8367 *E-mail Address: permits@roofmylakeh use.com Cell Phone Number: _______________ Fax Number:--------------+---------- Page 4 of 4 Updated 06/21/21 BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats & Facts Publications Contact Us BCIS Site Map Links Search Product Approval USER: Public User Product Approval Menu > Product or Application Search > Application List > Application Detail FL #FL17411-R6 Application Type Affirmation Code Version 2020 Application Status Approved Comments Archived Product Manufacturer Roser Co., Ltd. Address/Phone/Email 400 Nae-ri Apryang-myeon Gyongsan-si, NON-US 00000(053) 817-5000 jkim77@roser.com Authorized Signature Jitaek Kimjkim77@roser.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Metal Roofing Compliance Method Certification Mark or Listing Certification Agency Miami-Dade BCCO - CER Validated By Miami-Dade BCCO - VAL Referenced Standard and Year (of Standard)Standard Year TAS100 1995 TAS125 2003 Equivalence of Product Standards Certified By Approved Certification Agency FL17411_R6_Equiv_19032501.pdf I affirm that there are no changes in the new Florida Building Code which affect my product(s) and my product(s) are in compliance with the new Florida Building Code. Documentation from approved Evaluation or Validation Entity Yes No N/A By Toni Gindlesperger at 11:29 am, Jun 10, 2022 By Mike Jones at 1:37 pm, Jun 17, 2022 FLCAIOA O&PAATMINT OF Business & Professional Regulation ► Of'FICE OF THE SECRETARY -------- [ RECEIVED JOB COPY D [ REVIEWED ] 0 0 0 Product Approval Method Method 1 Option A Date Submitted 12/09/2020 Date Validated 12/09/2020 Date Pending FBC Approval Date Approved 12/12/2020 Summary of Products FL #Model, Number or Name Description 17411.1 Cleo, Rowood, Roser Bond, Stonewood Shake, Spany, PianoPanels Panels fastened to battens or plywood deck Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-156 Other: Design of 156 psf for battten attachment and design pressure of 131.75 psf for deck attachment Certification Agency Certificate FL17411_R6_C_CAC_19032501.pdfQuality Assurance Contract Expiration Date 04/04/2024Installation Instructions FL17411_R6_II_19032501.pdf Verified By: Miami-Dade BCCO - CER Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: Back Next Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida. :: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public-records request, do not send electronicmail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emailsprovided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, pleaseprovide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: DD Credit Card Safe securilVJ\iHKICS ,, JOB COPY By Toni Gindlesperger at 11:30 am, Jun 10, 2022 By Mike Jones at 1:39 pm, Jun 17, 2022 r,OQ CA CCPAAT~·vv 0~ Business & Professional Regulation BCIS Home I Log In I User Registration I Hot Topics I Submit Surcharge I Stats & Facts I Publications I Contact Us I BCIS Site Map Links Search ~& ~ ~rur raProductApproval ~~r-' ~USER: Public User [ RECEIVED ► OFFICE OF THE SECRETARY Product A1;u;iroval Menu > Product or Ai;ii;ilication Search > tii;ii;ilication List > Application Detail FL# Application Type Code Version Application Status Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method FL5259-R32 Revision 2020 Approved D [REVIEWED POLYGLASS USA 1111 W. Newport Center Drive Deerfield Beach, FL 33442 {954) 233-1330 Ext 242 malpert@polyglass.com Maury Alpert malpert@polyglass.com TECH REP 1111 West Newport Center Drive Deerfield Beach, FL 33442 (866) 802-8017 uspolyglasstechnical@polyglass.com QA REP 1111 West Newport Center Drive Deerfield Beach, FL 33442 (888) 410-1375 uspolyglasstechnical@polyglass.com Roofing Underlayments JOB COPY Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report -Hardcopy Received Florida Engineer or Architect Name who developed the Robert Nieminen Evaluation Report Florida License Quality Assurance Entity Quality Assurance Contract Expiration Date Validated By Certificate of Independence Referenced Standard and Year (of Standard) PE-59166 UL LLC 12/23/2023 John W. Knezevich, PE Validation Checklist -Hardcopy Received FL5259 R32 COi 2020 01 COi NIEMINEN,P-df Standard ASTM D1970 ASTM D226 ASTM D4798 ASTM D6163 ASTM D6164 ASTM D6222 Yllr 2015 2009 2011 2015 2011 2011 ] JOB COPY Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Date Revised Summary of Products FL# Model, Number or Name 5259.1 Polyglass Roof Underlayments (HVHZ) Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: No Impact Resistant: N/ A Design Pressure: N/ A Other: Refer to ER Section 5 for Limits of Use. 5259.2 Polyglass Roof Underlayments (non-HVHZ) Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/ A Design Pressure: +N/N-622.5 Other: 1.) The design pressure in this application relates to one particular underlayment system for use in tile roof systems. Refer to ER Section 5.8.3 for other systems and associated maximum design pressures. 2.) Refer to ER Section 5 for other limits of use. ASTM D6509 FM 4474 FRSA/TRI, Sixth Edition TAS 103 UL 1897 Method 1 Option D 12/21/2020 12/21/2020 12/26/2020 02/09/2021 04/07/2021 Description 2015 2011 2018 2020 2015 Polyglass roof underlayments for use in FBC HVHZ jurisdictions. Installation Instructions FLS2S2 RJ2 II 2Q2Q 12 21 FINAL ER PLYG UNDERLAYMENTS FLS2S2- R32 (HVHZ)..12df Verified By: Robert Nieminen PE-59166 Created by Independent Third Party: Yes Evaluation Reports FL5259 R32 AE 2020 12 21 FINAL ER PLYG UNDERLAYMENTS FL5259- R32 (HVHZ)..P-df Created by Independent Third Party: Yes Polyglass roof underlayments, for use in FBC non-HVHZ jurisdictions. Installation Instructions FL5259 R32 II 2020 12 21 FINAL ER PLYG UNDERLAYMENTS FL5259- R32 (NON-HVHZ)_.12df Verified By: Robert Nieminen PE-59166 Created by Independent Third Party: Yes Evaluation Reports FL5259 R32 AE 2020 12 21 FINAL ER PLYG UNDERLAYMENTS FL5259- Rll...(NON-HVHZ)..w;!f Created by Independent Third Party: Yes contact us : : 2601 Blair stone Road Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. CoP..'l.tlght 2007-2013 State of Florida. : : Privacy Statement : : Accessibility Statement : : Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public-records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact B50.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here • Product Approval Accepts: ~[Cl:][ill ~- Credit Card Safe sccuril \'M1:nucs NOA: 19-0325.01 Expiration Date: 04/04/24 Approval Date: 05/16/19 Page 1 of 10 MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474 T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/economy Roser Co. LTD 400, Nae-Ri, Apryang-Myeon, Gyongsan-Si Gyongsanbuk-Do, South Korea SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami-Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Cleo, Rowood, Roser Bond, Stonewood Shake, Spany and Piano Panels. LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami-Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA # 19-0319.03 and consists of pages 1 through 10. The submitted documentation was reviewed by Freddy Semino By Toni Gindlesperger at 10:05 am, Jun 24, 2022By Mike Jones at 12:19 pm, Jul 01, 2022 MIAMI·· A•Mit• iill' [ REVIEWED ] JOB COPY ·---------[ RECEIVED l -- NOA: 19-0325.01 Expiration Date: 04/04/24 Approval Date: 05/16/19 Page 2 of 10 ROOFING SYSTEM APPROVAL: Category: Roofing Sub-Category: Metal, Panels (Non-Structural) Material: Steel Deck Type: Wood Maximum Design Pressure: -156 psf. TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: Product Dimensions Test Specifications Product Description Cleo Panel 53-1/8” x 14-3/8” Thickness min. 26 ga. Min Tensile Strength: 58ksi TAS 110 Galvalume steel, stone coated metal panel shingle. Rowood Panel 52-3/4” x 14-1/2” Thickness min. 26 ga. Min Tensile Strength: 58ksi TAS 110 Galvalume steel, stone coated metal panel shingle. Roser Bond Panel 53-1/8” x 14-1/2” Thickness min. 26 ga. Min Tensile Strength: 58ksi TAS 110 Galvalume steel, stone coated metal panel shingle. Stonewood Shake Panel 53-1/8” x 14-1/2” Thickness min. 26 ga. Min Tensile Strength: 58ksi TAS 110 Galvalume steel, stone coated metal panel shingle. Spany Panel 52-1/8” x 14-3/4” Thickness min. 26ga. Min Tensile Strength: 58ksi TAS 110 Galvalume steel, stone coated metal panel shingle. Piano Panel 52-3/4” x 14-3/8” Thickness min. 26ga. Min Tensile Strength: 58ksi TAS 110 Galvalume steel, stone coated metal panel shingle. MANUFACTURING LOCATION 1. Gyeongsangbuk-Do, South Korea JOB COPY - NOA: 19-0325.01 Expiration Date: 04/04/24 Approval Date: 05/16/19 Page 3 of 10 EVIDENCE SUBMITTED: Test Agency Test Identifier Test Name/Report Date Hurricane Test Laboratory, Inc. 0474-0513-07 TAS 125 07/02/07 0474-0514-07 TAS 125 07/02/07 PRI Construction Materials RCL-002-02-01 TAS 100 07/24/07 RCL-003-02-01 TAS 100 07/24/07 RCL-001-02-01 ASTM B 117 10/30/06 RCL-001-02-02 ASTM G 26 08/07/06 RCL-004-02-01 ASTM B-117 08/22/18 RCL-004-02-02 ASTM G-155 08/22/18 NOA: 19-0325.01 Expiration Date: 04/04/24 Approval Date: 05/16/19 Page 4 of 10 APPROVED ASSEMBLIES: System A(1): Cleo, Rowood, Roser Bond, Stonewood Shake, Spany and Piano Panels. Deck Type: Wood, Non-insulated Deck Description: New Construction 19/32” or greater plywood or wood plank, or Re-roof 15/32” or greater plywood or wood plank. Slope Range: 2:12 or greater Maximum Uplift Pressure: See Fastening Options Below Deck Attachment: In accordance with applicable Building Code, but in no case shall it be less than 8d annular ring shank nails spaced 6”o.c. In reroofing, where the deck is less than 19/32” thick (Minimum 15/32”) The above attachment method must be in addition to existing attachment. Underlayment: Minimum underlayment shall be an ASTM D 226 Type II installed with a minimum 4” side-lap and 6” end-laps. Underlayment shall be fastened with corrosion resistant tin-caps and 12 gauge 1 ¼” annular ring-shank nails, spaced 6”o.c. at all laps and two staggered rows 12”o.c. in the field of the roll. Or, any approved underlayment having a current NOA. Fire Barrier Board: Any approved fire barrier having a current NOA. Refer to a current fire directory listing for fire ratings of this roofing system assembly as well as the location of the fire barrier within the assembly. See Limitation # 1. Valleys: Valley construction shall be in compliance with Roofing Application Standard RAS 133 and with Roser Co. LTD's current published installation instructions. Metal Panels and Accessories: Install the " Cleo, Rowood, Roser Bond, Stonewood Shake, Spany, Piano Panels” and accessories in compliance with Roser Co. LTD's current, published installation instructions and details. Flashings, penetrations, valley construction and other details shall be constructed in compliance with the minimum requirements provided in Roofing Application Standard RAS 133. Panels shall be fastened with corrosion resistant 2-1/4” x ¼” dia. Hex head screws approximately 7”o.c. with a minimum of 8 on the top edge and 8 on the bottom edge. Fasteners listed herein are to be placed on the front of the panel (exposed) and along the back of the panel (concealed). (See detail drawings herein). Maximum Design Pressure: -131.75 psf. (See General Limitation #2) NOA: 19-0325.01 Expiration Date: 04/04/24 Approval Date: 05/16/19 Page 5 of 10 System A(2): Cleo, Rowood, Roser Bond, Stonewood Shake, Spany and Piano Panels Deck Type: Wood, Non-insulated Deck Description: New Construction 19/32” or greater plywood or wood plank, or Re-roof 15/32” or greater plywood or wood plank. Slope Range: 2:12 or greater Maximum Uplift Pressure: See Fastening Options Below Deck Attachment: In accordance with applicable Building Code, but in no case shall it be less than 8d annular ring shank nails spaced 6”o.c. In reroofing, where the deck is less than 19/32” thick (Minimum 15/32”) The above attachment method must be in addition to existing attachment. Underlayment: Minimum underlayment shall be an ASTM D 226 Type II installed with a minimum 4” side-lap and 6” end-laps. Underlayment shall be fastened with corrosion resistant tin-caps and 12 gauge 1 ¼” annular ring-shank nails, spaced 6”o.c. at all laps and two staggered rows 12”o.c. in the field of the roll. Or, any approved underlayment having a current NOA. Fire Barrier Board: Any approved fire barrier having a current NOA. Refer to a current fire directory listing for fire ratings of this roofing system assembly as well as the location of the fire barrier within the assembly. See Limitation # 1. Valleys: Valley construction shall be in compliance with Roofing Application Standard RAS 133 and with Roser Co. LTD's current published installation instructions. Battens: Install 1” x 4” (nominal) southern Yellow Pine battens at 14-1/2”o.c. using two (2), 8d x 2-3/8” corrosion resistant ring shank nails spaced 12”o.c. Metal Panels and Accessories: Install the " Cleo, Rowood, Roser Bond, Stonewood Shake, Spany, Piano Panels” and accessories in compliance with Roser Co. LTD's current, published installation instructions and details. Flashings, penetrations, valley construction and other details shall be constructed in compliance with the minimum requirements provided in Roofing Application Standard RAS 133. Panels shall be fastened with corrosion resistant 2-1/4” x ¼” dia. Hex head screws approximately 7”o.c. with a minimum of 8 on the bottom edge into the battens. Fasteners listed herein are to be placed on the front of the panel (exposed) through the top lip of the previous panel and into the batten. (See detail drawings herein). Maximum Design Pressure: -156 psf. (See General Limitation #2) JOB COPY NOA: 19-0325.01 Expiration Date: 04/04/24 Approval Date: 05/16/19 Page 6 of 10 LIMITATIONS: 1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. The maximum designed pressure listed herein shall be applicable to all roof pressure zones (i.e. field, perimeters, and corners). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at enhanced pressure zones (i.e. perimeters, extended corners and corners). 3. All panels shall be permanently labeled with the manufacturer’s name and/or logo, city and state of manufacturing facility, and the following statement: “Miami-Dade County Product Control Approved” or with the Miami-Dade County Product Control Seal as seen below. 4. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61G20-3 of the Florida Administrative Code. NOA: 19-0325.01 Expiration Date: 04/04/24 Approval Date: 05/16/19 Page 7 of 10 PROFILE DRAWINGS: SYSTEM A-1 INSTALLATION DETAIL SYSTEM A-2 INSTALLATION DETAIL (WITH BATTENS) Metal Panel Metal Panel Exposed 8d x 2-i" long ring shank nail. 2-l x l" diam. hex head screws Concealed Exposed Nominal 1" x 4" battens JOB COPY Concealed 2-l x l" diam. hex head - NOA: 19-0325.01 Expiration Date: 04/04/24 Approval Date: 05/16/19 Page 8 of 10 CLEO PANEL ROWOOD PANEL 52-3/4" 14 1/2" 53-1/8" 14-3/8" NOA: 19-0325.01 Expiration Date: 04/04/24 Approval Date: 05/16/19 Page 9 of 10 ROSER BOND PANEL STONEWOOD SHAKE PANEL 53-1/8"14 1/2"53-1/8 "14 1/2" NOA: 19-0325.01 Expiration Date: 04/04/24 Approval Date: 05/16/19 Page 10 of 10 END OF TH Spany Panel Piano Panel END OF THIS ACCEPTANCE NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R35 for FL5680-R35 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 35: 04/11/2022 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 1 of 96 APPENDIX 1: ATTACHMENT REQUIREMENTS FOR WIND UPLIFT RESISTANCE TABLE DECK APPLICATION TYPE DESCRIPTION PAGE 1A Wood New, Reroof (Tear-Off) A-1 Bonded Insulation, Bonded Roof Cover 6 1B Wood New, Reroof (Tear-Off) A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 6-10 1C Wood New, Reroof (Tear-Off), Recover A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 10-13 1D Wood New, Reroof (Tear-Off), Recover B-1 Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 14 1E Wood New, Reroof (Tear-Off), Recover C-1 Mech. Attached Insulation, Bonded Roof Cover 14-15 1F Wood New, Reroof (Tear-Off), Recover D-2 Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 16 1G Wood New, Reroof (Tear-Off) E-2 Non-Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 16-17 1H Wood New, Reroof (Tear-Off), Recover E-2 Non-Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 17-18 1I Wood New, Reroof (Tear-Off) F Non-Insulated, Bonded Roof Cover 18 2A Steel or Structural concrete New, Reroof (Tear-Off), Recover B-1 Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 19-29 2B Steel New, Reroof (Tear-Off), Recover B-2 Mech. Attached Thermal Barrier, Bonded Temp Roof, Bonded Insulation, Bonded Roof Cover 29-36 2C Steel or Structural concrete New, Reroof (Tear-Off), Recover C-1 Mech. Attached Insulation, Bonded Roof Cover 36-44 2D Steel or Structural concrete New, Reroof (Tear-Off), Recover C-1A Thermal Barrier with Vapor Barrier, Mech. Attached Insulation, Bonded Roof Cover 45 2E Steel or Structural concrete New, Reroof (Tear-Off), Recover C-3 Bonded and Mech. Attached Insulation, Bonded Roof Cover 45 2F Steel or Structural concrete New, Reroof (Tear-Off), Recover D-2 Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 46-49 3A Structural concrete New, Reroof (Tear-Off) A-1 Bonded Insulation, Bonded Roof Cover (Base Insulation Layer Only) 50-51 3B Structural concrete New, Reroof (Tear-Off) A-1 Bonded Insulation, Bonded Roof Cover (Base and Top Insulation Layers) 52-60 3C Structural concrete New, Reroof (Tear-Off) F Non-Insulated, Bonded Roof Cover 60 4A Lightweight concrete over concrete New, Reroof (Tear-Off) A-1 LWC to Deck, Bonded Insulation, Bonded Roof Cover 61 4B Lightweight concrete over steel or concrete New or Reroof (Tear-Off) A-2 LWC to Deck, Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 62 4C Lightweight concrete over steel or concrete New, Reroof (Tear-Off) E-2 LWC to Deck, Non-Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 63-66 4D Lightweight concrete over steel New, Reroof (Tear-Off) E-2 Thermal Barrier to Deck, Temp Roof to Barrier, LWC to Temp Roof, Mech. Attached Base Sheet, Bonded Roof Cover 67 4E Lightweight concrete over concrete New, Reroof (Tear-Off) F LWC to Deck, Non-Insulated, Bonded Roof Cover 67 5A Cementitious wood fiber New, Reroof (Tear-Off) A-1 Bonded Insulation, Bonded Roof Cover 68 5B Cementitious wood fiber New, Reroof (Tear-Off) A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 68-69 5C Cementitious wood fiber New, Reroof (Tear-Off) E-2 Non-Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 69-70 6A Gypsum Reroof (Tear-Off) A-1 Bonded Insulation, Bonded Roof Cover 71 6B Gypsum Reroof (Tear-Off) A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 71-72 6C Gypsum Reroof (Tear-Off) C-1 Mech. Attached Insulation, Bonded Roof Cover 72 6D Gypsum Reroof (Tear-Off) E-2 Non-Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 72-73 7A Various Recover A-1 Bonded Insulation, Bonded Roof Cover (Base Insulation Layer Only) 74-81 7B Various Recover A-1 Bonded Insulation, Bonded Roof Cover (Base and Top Insulation Layers) 82-96 By Toni Gindlesperger at 10:07 am, Jun 24, 2022 By Mike Jones at 12:24 pm, Jul 01, 2022 [REVIEWED ] J_o_s _co_P_v_l R [ RECEIVED . ~ NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R35 for FL5680-R35 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 35: 04/11/2022 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 2 of 96 The following notes apply to the systems outlined herein: 1 The roof system evaluation herein pertains to above-deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. 2 Unless otherwise noted, fasteners and stress plates shall be as follows. Fasteners shall be of sufficient length for the following engagements: FASTENER/PLATE OPTIONS DECK TYPE BY PARTS MINIMUM ENGAGEMENT Wood GAF Drill-Tec #12 Fastener or Drill-Tec #14 Fastener with Drill-Tec 3” Standard Steel Plate, Drill-Tec 3” Steel Plate or Drill-Tec AccuTrac Flat Plate or Drill-Tec AccuTrac Recessed Plate (insulation only), Drill-Tec ASAP 3S, Drill-Tec Heavy Duty ASAP Roofing Fastener Assembled with a 3” Metal Plate, Drill-Tec #12 DP Fastener or Drill-Tec #14 HD Fastener with Drill-Tec 3” Flat Steel Plate, Drill-Tec #12 DPH Fastener with Drill-Tec 3” Recessed Steel Plate, Drill-Tec 3” ASAP Flat or Drill-Tec 3” ASAP Recessed Minimum ¾-inch plywood penetration or minimum 1- inch wood plank embedment Steel GAF Drill-Tec #12 Fastener, Drill-Tec #14 Fastener or Drill-Tec XHD Fastener with Drill-Tec 3” Standard Steel Plate, Drill-Tec 3” Steel Plate or Drill-Tec AccuTrac Flat Plate or Drill-Tec AccuTrac Recessed Plate (insulation only); Drill-Tec ASAP 3S; Drill-Tec Heavy Duty ASAP Roofing Fastener Assembled with a 3” Metal Plate; Drill-Tec Extra Heavy Duty ASAP Roofing Fastener - Insulation, Drill-Tec #12 DP Fastener, Drill- Tec #14 HD Fastener or Drill-Tec #15 EHD Fastener with Drill-Tec 3” Flat Steel Plate, Drill-Tec #12 DPH Fastener with Drill-Tec 3” Recessed Steel Plate, Drill-Tec 3” ASAP Flat or Drill-Tec 3” ASAP Recessed Minimum ¾-inch steel penetration and engage the top flute of the steel deck Structural Concrete GAF Drill-Tec #14 Fastener or Drill-Tec CD-10 with Drill-Tec 3” Standard Steel Plate, Drill-Tec 3” Steel Plate or Drill-Tec AccuTrac Flat Plate or Drill-Tec AccuTrac Recessed Plate (insulation only), Drill-Tec Heavy Duty ASAP Roofing Fastener Assembled with a 3” Metal Plate, Drill-Tec #14 HD Fastener with Drill-Tec 3” Flat Steel Plate or Drill-Tec 3” ASAP Flat (#14 only) Minimum 1-inch embedment. Fasteners installed with a pilot hole in accordance with the fastener manufacturer’s published installation instructions 3 Unless otherwise noted, insulation may be any one layer or combination of FBC Approved (Local or Statewide) board(s) that meet FBC 1505 and, for foam plastic, FBC Chapter 26, when installed with the roof cover. 4 Minimum 200 psi, minimum 2-inch thick FBC Approved lightweight insulating concrete may be substituted for, or installed below, rigid insulation board for System Types B-1, C-1, C-2, D-1 or D-2, whereby fasteners are installed through the lightweight insulating concrete to engage the structural deck. The structural deck shall be of equal or greater type, thickness and strength to the steel and structural concrete deck listings. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. This is a wind uplift resistance allowance and does not purport to address non-wind-uplift-related issues, such as deck venting or moisture levels within the LWIC and the potential effect on overlying components. 5 Preliminary insulation attachment for System Type D: Unless otherwise noted, refer to Section 2.2.10.1.3 of FM Loss Prevention Data Sheet 1-29 (February 2020). 6 Unless otherwise noted, insulation adhesive application rates are as follows. Ribbon or bead width is at the time of application; the ribbons/beads shall expand as noted in the manufacturer’s published instructions. INSULATION ADHESIVE REFERENCES BY ADHESIVE REFERENCE FBC FILE NO. MINIMUM RATE GAF GAF LRF Adhesive M ‘LRF-M’ N/A Continuous 0.75 to 1-inch ribbons, 12-inch o.c. GAF GAF LRF Adhesive XF ‘LRF-XF’ N/A Continuous 0.75 to 1-inch ribbons, 12-inch o.c. H.B. Fuller Company Millennium One Step Foamable Adhesive ‘M-OSFA’ FL1800 Continuous 0.25 to 0.5-inch wide ribbons, 12-inch o.c. OMG, Inc. OlyBond 500 Adhesive Fastener ‘OB500’ FL1608 Continuous 0.75-inch wide ribbons, 12-inch o.c. (PaceCart, SpotShot or Canister) Generic, ASTM D312, Type IV hot asphalt N/A N/A Full coverage at 25-30 lbs/square Note: If applying hot asphalt to concrete deck, deck shall be primed with ASTM D41 primer. Note: When multiple layers(s) of insulation and/or coverboard are installed in ribbon-applied adhesive, boards shall be staggered from layer-to-layer. Note: The maximum edge distance from the adhesive ribbon to the edge of the insulation board shall be not less than one-half the specified ribbons spacing NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R35 for FL5680-R35 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 35: 04/11/2022 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 3 of 96 7 Unless otherwise noted, all insulations are flat-stock or taper board of the minimum thickness noted. Tapered polyisocyanurate at the following thickness limitations may be substituted with the following Maximum Design Pressure (MDP) limitations. In no case shall these values be used to ‘increase’ the MDP listings in the tables; rather if MDP listing below meets or exceeds that listed for a particular system in the tables, then the thinner board listed below may be used as a drop-in for the equivalent thicker material listed in the table. MDP LIMITATIONS FOR TAPERED POLYISOCYANURATE INSULATIONS ADHESIVE INSULATION MIN. TAPERED THICKNESS (IN) MDP (PSF) LISTED PRODUCT FBC FILE NO. LRF-M EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation FL16311 0.5 -232.5 LRF-XF EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation FL16311 0.5 -292.5 LRF-XF EnergyGuard RA 18-0220.10 0.5 -487.5 M-OSFA Any EnergyGuard polyisocyanurate listed with adhesive herein various 0.5 -157.5 OB500 EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation FL16311 0.5 -292.5 OB500 EnergyGuard RH 19-1017.09 0.5 -315.0 OB500 EnergyGuard RN 18-1126.10 0.5 -315.0 OB500 EnergyGuard RA 18-0220.10 0.5 -487.5 Hot asphalt Any EnergyGuard polyisocyanurate listed with adhesive herein Various 0.5 -240.0 8 For adhered roof insulation and board-size: Unless otherwise noted, refer to Section 2.2.10.6.2 of FM Loss Prevention Data Sheet 1-29 (February 2020). 9 For mechanically attached components or partially-bonded insulation, the maximum design pressure for the selected assembly shall meet or exceed at least the Zone 1 PRIME design pressure determined in accordance with FBC Chapter 16. Elevated pressure zones shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29, Roofing Application Standard RAS 117 and Roofing Application Standard RAS 137. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (February 2020) for Zone 2/3 enhancements. 10 For assemblies with all components fully bonded, the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16. No rational analysis is permitted for these systems. 11 For mechanically attached components over existing decks, fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the minimum requirements for the system. Testing and analysis shall be in accordance with ANSI/SPRI FX-1 or Testing Application Standard TAS 105. 12 For bonded insulation or membrane over existing substrates in a re-roof (tear off) or recover installation, the existing deck or existing roof surface shall be examined for compatibility with the adhesive to be installed. If any surface conditions exist that bring system performance into question, field uplift testing shall be conducted on mock-ups of the proposed new roof assembly. For bonded insulation or membrane over existing substrates in a recover installation, the existing roof system shall be capable of resisting project design pressures on its own merit to the satisfaction of the Authority Having Jurisdiction, as documented through field uplift testing. Field uplift testing shall be in accordance with ASTM E907, FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124. 13 Refer to FBC 1511 for requirements and limitations regarding recover installations. For Structural Concrete Deck or Recover Applications using System Type C-1 the base insulation layer is optional and for System Type C-2, D-1 or D-2, the insulation is optional. Alternatively, an FBC Approved insulation board or coverboard may be used as a separation layer. Board products shall be preliminarily attached prior to roof cover installation (Note 5 herein). The separator component shall be documented as meeting FBC 1505 and, for foam plastic, FBC Chapter 26, when installed with the roof cover in Recover applications. 14 Lightweight insulating concrete (LWIC) shall be cast in accordance with FBC Section 1917 to the satisfaction of the Authority Having Jurisdiction. For systems where specific LWIC is referenced, refer to current LWIC Product Approval for specific deck construction and limitations. Unless otherwise noted, for systems where specific LWIC is not referenced, the minimum design mix shall be 300 psi. In all cases, the minimum top-coat thickness is 2-inches. For LWIC over structural concrete, reference is made to FBC Section 1917.4.1, Point 1. For “pre-existent” LWIC references, listings were established through testing over lightweight concrete cast using only foaming agent (ASTM C896), water and Portland cement (ASTM C150), with no proprietary additives, in accordance with procedures adopted by Miami-Dade BCCO (FBC CER1592). Use of these listings in new construction or re-roof (tear-off) applications is at the discretion of the Designer or Record and Authority Having Jurisdiction. NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R35 for FL5680-R35 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 35: 04/11/2022 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 4 of 96 15 For bonded membrane applications, unless otherwise noted, refer to the following. MEMBRANE / ADHESIVE COMBINATIONS REFERENCE LAYER MATERIAL APPLICATION BP-CA Base Ply: GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet Matrix 102 SBS Membrane Adhesive at 1.5 gal/sq. SBS-CA Base Ply or Ply: Ruberoid 20 Smooth Cap Ply: Ruberoid 30 Granule FR, Ruberoid EnergyCap 30 Granule FR, Ruberoid Mop Granule FR, Ruberoid Mop Plus Granule FR, Ruberoid EnergyCap Mop Plus Granule FR SBS-CA1 Base Ply: Ruberoid 20 Smooth or Ruberoid Mop Smooth 1.5 Matrix 101 Premium SBS Membrane Adhesive at 1.5 – 2.0 gal/square Cap Ply: Ruberoid 30 Granule FR, Ruberoid EnergyCap 30 Granule FR, Ruberoid Mop Plus Granule FR, Ruberoid EnergyCap Mop Plus Granule FR BP-AA Base Ply: GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet Hot asphalt at 25 lbs/square. Ply: One or more plies GAFGLAS Ply 4, GAFGLAS Ply 4 M, Tri-Ply Ply 4 Ply Sheet, GAFGLAS Flex Ply 6, GAFGLAS FlexPly 6 M SBS-AA Base Ply or Ply: One or two plies Ruberoid 20 Smooth, Ruberoid Mop Smooth, Ruberoid Mop Smooth 1.5, Ruberoid Mop Plus Smooth Cap Ply: Ruberoid 30 Granule, Ruberoid 30 Granule FR, Ruberoid EnergyCap 30 Granule FR, Ruberoid Mop Smooth, Ruberoid Mop Smooth 1.5, Ruberoid Mop Plus Smooth, Ruberoid Mop Granule FR, Ruberoid Mop Granule, Tri-Ply SBS Granule Cap Sheet, Intec Flex PRF, Ruberoid Mop Plus Granule FR, Ruberoid Mop Plus Granule, Ruberoid EnergyCap Mop Plus Granule FR SBS-TA Base Ply or Ply: One or two plies Ruberoid HW 25 Smooth, Ruberoid HW Smooth Torch-applied Cap Ply: Ruberoid HW Granule, Ruberoid HW Granule FR, Ruberoid HW Plus Granule, Ruberoid HW Plus Granule FR, Ruberoid EnergyCap HW Plus Granule FR APP-TA Base Ply or Ply: One or two plies Ruberoid Torch Smooth, Tri-Ply APP Smooth Membrane Torch-applied Cap Ply: Ruberoid Torch Granule, Tri-Ply APP Granule Membrane, Ruberoid Torch Plus Granule FR, Ruberoid EnergyCap Torch Granule FR, Ruberoid EnergyCap Torch Plus Granule FR SBS-SA Base Ply or Ply: Liberty SBS Self-Adhering Base/Ply Sheet Self-adhering Cap Ply Liberty SBS Self-Adhering Cap Sheet Note: Systems with a smooth-surfaced cap ply shall be surfaced in accordance with GAF requirements, meeting the fire resistance requirements of FBC Section 1505. Refer to FBC Section 1504.8 for limitations in the use of aggregate surfacing. 16 Vapor barrier options for use over structural concrete deck followed by bonded insulation carry the following Maximum Design Pressure (MDP) limitations. The lesser of the MDP listings below vs. that for the selected assembly from TABLE 3A or 3B applies. VAPOR BARRIER OPTIONS, STRUCTURAL CONCRETE DECK, ADHERED INSULATION OPTION # PRIMER VAPOR BARRIER INSULATION ADHESIVE PER TABLE 3A OR 3B MDP (PSF) TYPE APPLICATION C-VB-1. Matrix 307 Premium Asphalt Primer or ASTM D41 primer One or two plies, GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS Ply 4, GAFGLAS Ply 4 M, Tri-Ply Ply 4 Ply Sheet or GAFGLAS FlexPly 6, GAFGLAS FlexPly 6 M Hot asphalt applied Hot asphalt -360.0 C-VB-2. None GAF SA Vapor Retarder XL Self-adhering LRF-M, 12-inch o.c. -112.5 C-VB-3. Matrix 307 Premium Asphalt Primer or ASTM D41 primer Ruberoid HW 25 Smooth or Ruberoid HW Smooth Torch-applied LRF-M, 12-inch o.c. -180.0 C-VB-4. GAF SA Primer GAF SA Vapor Retarder Self-adhering LRF-M, 12-inch o.c. -202.5 C-VB-5. Matrix 307 Premium Asphalt Primer or ASTM D41 primer One or two plies, GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS Ply 4, GAFGLAS Ply 4 M, Tri-Ply Ply 4 Ply Sheet or GAFGLAS FlexPly 6, GAFGLAS FlexPly 6 M Hot asphalt applied LRF-M, 12-inch o.c. -495.0 C-VB-6. None GAF SA Vapor Retarder XL Self-adhering LRF-XF 12-inch o.c. -112.5 C-VB-7. Matrix 307 Premium Asphalt Primer or ASTM D41 primer Ruberoid Torch Granule Torch-applied LRF-XF, 12-inch o.c. -169.0 C-VB-8. Matrix 307 Premium Asphalt Primer or ASTM D41 primer Ruberoid HW 25 Smooth or Ruberoid HW Smooth Torch-applied LRF-XF, 12-inch o.c. -180.0 C-VB-9. GAF SA Primer GAF SA Vapor Retarder Self-adhering LRF-XF, 12-inch o.c. -202.5 JOB COPY ,------, .-·---, r l r , L NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R35 for FL5680-R35 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 35: 04/11/2022 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 5 of 96 VAPOR BARRIER OPTIONS, STRUCTURAL CONCRETE DECK, ADHERED INSULATION OPTION # PRIMER VAPOR BARRIER INSULATION ADHESIVE PER TABLE 3A OR 3B MDP (PSF) TYPE APPLICATION C-VB-10. Matrix 307 Premium Asphalt Primer or ASTM D41 primer Liberty SBS Self-Adhering Cap Sheet Self-adhering LRF-XF, 12-inch o.c. -250.0 C-VB-11. Matrix 307 Premium Asphalt Primer or ASTM D41 primer One or two plies, GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS Ply 4, GAFGLAS Ply 4 M, Tri-Ply Ply 4 Ply Sheet or GAFGLAS FlexPly 6, GAFGLAS FlexPly 6 M Hot asphalt applied LRF-XF, 12-inch o.c. -262.5 C-VB-12. Matrix 307 Premium Asphalt Primer or ASTM D41 primer Ruberoid 30 Hot asphalt applied LRF-XF, 12-inch o.c. -270.0 C-VB-13. None GAF SA Vapor Retarder XL Self-adhering OB500, 12-inch o.c. -127.5 C-VB-14. Matrix 307 Premium Asphalt Primer or ASTM D41 primer Ruberoid Torch Smooth Torch-applied OB500, 12-inch o.c. -165.0 C-VB-15. Matrix 307 Premium Asphalt Primer or ASTM D41 primer Ruberoid HW 25 Smooth Torch-applied OB500, 12-inch o.c. -180.0 C-VB-16. Matrix 307 Premium Asphalt Primer or ASTM D41 primer Liberty SBS Self-Adhering Cap Sheet Self-adhering OB500, 12-inch o.c. -187.5 C-VB-17. Matrix 307 Premium Asphalt Primer or ASTM D41 primer Ruberoid 20 Smooth Matrix 102 SBS Membrane Adhesive at 1.5 gal/square OB500, 12-inch o.c. -202.5 C-VB-18. GAF SA Primer GAF SA Vapor Retarder Self-adhering OB500, 12-inch o.c. -202.5 C-VB-19. Matrix 307 Premium Asphalt Primer or ASTM D41 primer Ruberoid Torch Granule Torch-applied OB500, 12-inch o.c. -225.0 C-VB-20. Matrix 307 Premium Asphalt Primer or ASTM D41 primer Ruberoid HW Smooth Torch-applied OB500, 12-inch o.c. -232.5 C-VB-21. Matrix 307 Premium Asphalt Primer or ASTM D41 primer One or two plies, GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS Ply 4, GAFGLAS Ply 4 M, Tri-Ply Ply 4 Ply Sheet or GAFGLAS FlexPly 6, GAFGLAS FlexPly 6 M Hot asphalt applied OB500, 12-inch o.c. -352.5 16A Vapor barrier options for use over structural concrete deck followed by cellular lightweight concrete carry the following Maximum Design Pressure (MDP) limitations. The lesser of the MDP listings below vs. that for the selected assembly from TABLE 4A through 4E applies. VAPOR BARRIER OPTIONS; STRUCTURAL CONCRETE DECK FOLLOWED BY CELLULAR LIGHTWEIGHT INSULATING CONCRETE OPTION # PRIMER VAPOR BARRIER LIGHTWEIGHT CONCRETE PER TABLE 4A – 4E (NOTE 14) MDP (PSF) TYPE ATTACH LWC-VB-1. Matrix 307 Premium Asphalt Primer or ASTM D41 primer Base Ply (Optional): One or two plies Ruberoid HW 25 Smooth, Ruberoid HW Smooth Cap Ply: Ruberoid HW Granule, Ruberoid HW Granule FR, Ruberoid HW Plus Granule, Ruberoid HW Plus Granule FR Torch- applied Min. 200 psi Mearlcrete (FL13492) -82.5 LWC-VB-2. Matrix 307 Premium Asphalt Primer or ASTM D41 primer Base Ply (Optional): One or two plies Ruberoid HW 25 Smooth, Ruberoid HW Smooth Cap Ply: Ruberoid HW Granule, Ruberoid HW Granule FR, Ruberoid HW Plus Granule, Ruberoid HW Plus Granule FR Torch- applied Min. 300 psi Celcore Cellular Concrete (FL2037) -135.0 LWC-VB-3. Matrix 307 Premium Asphalt Primer or ASTM D41 primer Base Ply (Optional): One or two plies Ruberoid HW 25 Smooth, Ruberoid HW Smooth Cap Ply: Ruberoid HW Granule, Ruberoid HW Granule FR, Ruberoid HW Plus Granule, Ruberoid HW Plus Granule FR Torch- applied Min. 300 psi Elastizell (NOA 18-0208.03) -302.5 LWC-VB-4. Matrix 307 Premium Asphalt Primer or ASTM D41 primer Ruberoid HW 25 Smooth, Ruberoid HW Smooth Torch- applied Min. 540 psi pre-existent cellular LWC -358.0 17 Fire barriers of FireOut™ Fire Barrier Coating or VersaShield® Solo™ Fire-Resistant Slip Sheet are optional in all assemblies when overlying components are mechanically fastened. NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R35 for FL5680-R35 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 35: 04/11/2022 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 6 of 96 18 The following products are interchangeable within the scope of this Evaluation Report: ACCEPTABLE ALTERNATES SUB-CATEGORY MANUFACTURER FBC FILE NO. LISTED PRODUCT HEREIN ALTERNATE Roofing Insulation GAF FL16311 EnergyGuard Polyiso Insulation EnergyGuard NH Polyiso Insulation EnergyGuard Ultra Polyiso Insulation EnergyGuard NH Ultra Polyiso Insulation EnergyGuard HD Polyiso Cover Board EnergyGuard HD Barrier Polyiso Cover Board, EnergyGuard NH HD Polyiso Cover Board EnergyGuard HD Plus Polyiso Cover Board EnergyGuard NH HD Plus Polyiso Cover Board Georgia-Pacific Gypsum, LLC FL1250 DensDeck Prime DensDeck StormX Prime Roof Board Vapor Barrier GAF N/A GAF SA Vapor Retarder XL GAF SA Vapor Retarder XL40 19 For System Types B-1, B-2, C-1, C-2, D-1 or Type D-2, GAF SA Vapor Retarder or GAF SA Vapor Retarder XL may be installed atop the roof deck, or to a loose-laid thermal barrier of DensDeck Prime or SECUROCK Gypusm-Fiber Roof Board, prior to installation of the insulation and roof cover. When adhering GAF SA Vapor Retarder to structural concrete, the substrate shall be primed with GAF SA Primer. When adhering GAF SA Vapor Retarder to DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board, the substrate shall be primed with GAF SA Primer or Matrix 307 Premium Asphalt Primer. Refer to FM Loss Prevention Data Sheet 1-29 (February 2020) for design and installation limitations. 20 “MDP” = Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads. Refer to FBC 1609 for determination of design wind loads TABLE 1A: WOOD DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER Sys No. Deck (Note 1) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply W-1. Min. 19/32-inch plywood or OSB; 2 ft span Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation, EnergyGuard RA, EnergyGuard RH LRF-XF Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-XF BP-AA, SBS-AA, SBS-TA or APP- TA (Optional) One or more BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS- TA or APP-TA -52.5 TABLE 1B: WOOD DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 15) MDP (psf) Type Fasteners (Note 11) Attach Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply CONVENTIONAL SYSTEMS: W-2. Min. 15/32- inch plywood or 1-inch wood plank; 2 ft span GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth 32 ga., 1- 5/8-inch dia. tin caps with 11 ga. annular ring shank nails 8-inch o.c. at min. 4-inch laps and 8-inch o.c. in two, equally spaced, staggered center rows Min. 1-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation or EnergyGuard RH Polyiso or min. 1.5- inch EnergyGuard RA or EnergyGuard RN Hot asphalt Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation or EnergyGuard Perlite Recover Board or Min. 0.75-inch EnergyGuard Perlite Roof Insulation (homogeneous) Hot asphalt BP-AA, SBS- AA (Optional) BP-AA, SBS-AA, SBS-TA, APP-TA SBS- AA, SBS-TA, APP-TA -45.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R35 for FL5680-R35 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 35: 04/11/2022 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 7 of 96 TABLE 1B: WOOD DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 15) MDP (psf) Type Fasteners (Note 11) Attach Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply W-3. Min. 15/32- inch plywood or 1-inch wood plank; 2 ft span GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth 32 ga., 1- 5/8-inch dia. tin caps with 11 ga. annular ring shank nails 8-inch o.c. at min. 4-inch laps and 8-inch o.c. in two, equally spaced, staggered center rows Min. 1-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation or EnergyGuard RH Polyiso or min. 1.5- inch EnergyGuard RA or EnergyGuard RN Hot asphalt Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Hot asphalt BP-AA, SBS- AA, SBS-TA, APP-TA (Optional) BP-AA, SBS-AA, SBS-TA, APP-TA SBS- AA, SBS-TA, APP-TA -45.0 W-4. Min. 19/32- inch plywood or 1-inch wood plank; 2 ft span GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Eliminator Nailable Venting Base Sheet, Ruberoid 20 Smooth, Ruberoid Mop Smooth, Ruberoid Mop Smooth 1.5 32 ga., 1- 5/8-inch dia. tin caps with 11 ga. annular ring shank nails 9-inch o.c. at the min. 4-inch lap and 12-inch o.c. in two, equally spaced, staggered center rows Min. 1-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation or EnergyGuard RH Polyiso or min. 1.5- inch EnergyGuard RA or EnergyGuard RN Hot asphalt Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation or EnergyGuard Perlite Recover Board or Min. 0.75-inch EnergyGuard Perlite Roof Insulation (homogeneous) Hot asphalt BP-AA, SBS- AA (Optional) BP-AA, SBS-AA, SBS-TA, APP-TA SBS- AA, SBS-TA, APP-TA -45.0 W-5. Min. 19/32- inch plywood or 1-inch wood plank; 2 ft span GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Eliminator Nailable Venting Base Sheet, Ruberoid 20 Smooth, Ruberoid Mop Smooth, Ruberoid Mop Smooth 1.5 32 ga., 1- 5/8-inch dia. tin caps with 11 ga. annular ring shank nails 9-inch o.c. at the min. 4-inch lap and 12-inch o.c. in two, equally spaced, staggered center rows Min. 1-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation or EnergyGuard RH Polyiso or min. 1.5- inch EnergyGuard RA or EnergyGuard RN Hot asphalt Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Hot asphalt BP-AA, SBS- AA, SBS-TA, APP-TA (Optional) BP-AA, SBS-AA, SBS-TA, APP-TA SBS- AA, SBS-TA, APP-TA -45.0 W-6. Min. 15/32- inch plywood or 1-inch wood plank; 2 ft span GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth 32 ga., 1- 5/8-inch diameter tin caps with 12 ga. annular ring shank nails 6-inch o.c. at the 4-inch lap and 6- inch o.c. in two staggered center rows Min. 1-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation or EnergyGuard RH Polyiso or min. 1.5- inch EnergyGuard RA or EnergyGuard RN Hot asphalt Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation or EnergyGuard Perlite Recover Board or Min. 0.75-inch EnergyGuard Perlite Roof Insulation (homogeneous) Hot asphalt BP-AA, SBS- AA (Optional) BP-AA, SBS-AA, SBS-TA, APP-TA SBS- AA, SBS-TA, APP-TA -52.5 W-7. Min. 15/32- inch plywood or 1-inch wood plank; 2 ft span GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth 32 ga., 1- 5/8-inch diameter tin caps with 12 ga. annular ring shank nails 6-inch o.c. at the 4-inch lap and 6- inch o.c. in two staggered center rows Min. 1-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation or EnergyGuard RH Polyiso or min. 1.5- inch EnergyGuard RA or EnergyGuard RN Hot asphalt Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Hot asphalt BP-AA, SBS- AA, SBS-TA, APP-TA (Optional) BP-AA, SBS-AA, SBS-TA, APP-TA SBS- AA, SBS-TA, APP-TA -52.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R35 for FL5680-R35 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 35: 04/11/2022 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 8 of 96 TABLE 1B: WOOD DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 15) MDP (psf) Type Fasteners (Note 11) Attach Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply W-8. Min. 19/32- inch plywood or 1-inch wood plank; 2 ft span GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth 32 ga., 1- 5/8-inch diameter tin caps with 12 ga. annular ring shank nails 8-inch o.c. at the 4-inch lap and 8- inch o.c. in two staggered center rows Min. 1-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation or EnergyGuard RH Polyiso or min. 1.5- inch EnergyGuard RA or EnergyGuard RN Hot asphalt Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation or EnergyGuard Perlite Recover Board or Min. 0.75-inch EnergyGuard Perlite Roof Insulation (homogeneous) Hot asphalt BP-AA, SBS- AA (Optional) BP-AA, SBS-AA, SBS-TA, APP-TA SBS- AA, SBS-TA, APP-TA -52.5 W-9. Min. 19/32- inch plywood or 1-inch wood plank; 2 ft span GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth 32 ga., 1- 5/8-inch diameter tin caps with 12 ga. annular ring shank nails 8-inch o.c. at the 4-inch lap and 8- inch o.c. in two staggered center rows Min. 1-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation or EnergyGuard RH Polyiso or min. 1.5- inch EnergyGuard RA or EnergyGuard RN Hot asphalt Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Hot asphalt BP-AA, SBS- AA, SBS-TA, APP-TA (Optional) BP-AA, SBS-AA, SBS-TA, APP-TA SBS- AA, SBS-TA, APP-TA -52.5 W-10. Min. 19/32- inch plywood or 1-inch wood plank; 2 ft span GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Eliminator Nailable Venting Base Sheet, Ruberoid 20 Smooth, Ruberoid Mop Smooth, Ruberoid Mop Smooth 1.5 32 ga., 1- 5/8-inch dia. tin caps with 11 ga. annular ring shank nails 9-inch o.c. at the min. 4-inch lap and 9-inch o.c. in two, equally spaced, staggered center rows Min. 1-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation or EnergyGuard RH Polyiso or min. 1.5- inch EnergyGuard RA or EnergyGuard RN Hot asphalt Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation or EnergyGuard Perlite Recover Board or Min. 0.75-inch EnergyGuard Perlite Roof Insulation (homogeneous) Hot asphalt BP-AA, SBS- AA (Optional) BP-AA, SBS-AA, SBS-TA, APP-TA SBS- AA, SBS-TA, APP-TA -60.0 W-11. Min. 19/32- inch plywood or 1-inch wood plank; 2 ft span GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Eliminator Nailable Venting Base Sheet, Ruberoid 20 Smooth, Ruberoid Mop Smooth, Ruberoid Mop Smooth 1.5 32 ga., 1- 5/8-inch dia. tin caps with 11 ga. annular ring shank nails 9-inch o.c. at the min. 4-inch lap and 9-inch o.c. in two, equally spaced, staggered center rows Min. 1-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation or EnergyGuard RH Polyiso or min. 1.5- inch EnergyGuard RA or EnergyGuard RN Hot asphalt Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Hot asphalt BP-AA, SBS- AA, SBS-TA, APP-TA (Optional) BP-AA, SBS-AA, SBS-TA, APP-TA SBS- AA, SBS-TA, APP-TA -60.0 SELF-ADHERING BASE PLY: NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R35 for FL5680-R35 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 35: 04/11/2022 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 9 of 96 TABLE 1B: WOOD DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 15) MDP (psf) Type Fasteners (Note 11) Attach Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply W-12. Min. 19/32- inch plywood or 1-inch wood plank; 2 ft span GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Eliminator Nailable Venting Base Sheet, Ruberoid 20 Smooth, Ruberoid Mop Smooth, Ruberoid Mop Smooth 1.5 32 ga., 1- 5/8-inch dia. tin caps with 11 ga. annular ring shank nails 9-inch o.c. at the min. 2-inch lap and 12-inch o.c. in two, equally spaced, staggered center rows Min. 1-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation or EnergyGuard RH Polyiso or min. 1.5- inch EnergyGuard RA or EnergyGuard RN Hot asphalt Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Hot asphalt SBS-SA (Optional) SBS-SA, SBS-TA or APP-TA SBS-SA, SBS-TA or APP- TA -45.0 VENTING SYSTEMS: W-13. Min. 15/32- inch plywood or 1-inch wood plank; 2 ft span GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth 32 ga., 1- 5/8-inch dia. tin caps with 11 ga. annular ring shank nails 8-inch o.c. at min. 4-inch laps and 8-inch o.c. in two, equally spaced, staggered center rows Min. 1-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation or EnergyGuard RH Polyiso Hot asphalt (Optional) Additional layer(s) base insulation Hot asphalt GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) BP-AA, SBS-AA SBS-AA -45.0 W-14. Min. 19/32- inch plywood or 1-inch wood plank; 2 ft span GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Eliminator Nailable Venting Base Sheet, Ruberoid 20 Smooth, Ruberoid Mop Smooth, Ruberoid Mop Smooth 1.5 32 ga., 1- 5/8-inch dia. tin caps with 11 ga. annular ring shank nails 9-inch o.c. at the min. 4-inch lap and 12-inch o.c. in two, equally spaced, staggered center rows Min. 1-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation or EnergyGuard RH Polyiso Hot asphalt (Optional) Additional layer(s) base insulation Hot asphalt GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) BP-AA, SBS-AA SBS-AA -45.0 W-15. Min. 15/32- inch plywood or 1-inch wood plank; 2 ft span GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth 32 ga., 1- 5/8-inch dia. tin caps with 11 ga. annular ring shank nails 6-inch o.c. at min. 4-inch laps and 6-inch o.c. in two, equally spaced, staggered center rows Min. 1-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation or EnergyGuard RH Polyiso Hot asphalt (Optional) Additional layer(s) base insulation Hot asphalt GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) BP-AA, SBS-AA SBS-AA -52.5 W-16. Min. 19/32- inch plywood or 1-inch wood plank; 2 ft span GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth 32 ga., 1- 5/8-inch diameter tin caps with 12 ga. annular ring shank nails 8-inch o.c. at the 4-inch lap and 8- inch o.c. in two staggered center rows Min. 1-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation or EnergyGuard RH Polyiso Hot asphalt (Optional) Additional layer(s) base insulation Hot asphalt GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) BP-AA, SBS-AA SBS-AA -52.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R35 for FL5680-R35 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 35: 04/11/2022 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 10 of 96 TABLE 1B: WOOD DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 15) MDP (psf) Type Fasteners (Note 11) Attach Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply W-17. Min. 19/32- inch plywood or 1-inch wood plank; 2 ft span GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Eliminator Nailable Venting Base Sheet, Ruberoid 20 Smooth, Ruberoid Mop Smooth, Ruberoid Mop Smooth 1.5 32 ga., 1- 5/8-inch dia. tin caps with 11 ga. annular ring shank nails 9-inch o.c. at the min. 4-inch lap and 9-inch o.c. in two, equally spaced, staggered center rows Min. 1-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation or EnergyGuard RH Polyiso Hot asphalt (Optional) Additional layer(s) base insulation Hot asphalt GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) BP-AA, SBS-AA SBS-AA -60.0 TABLE 1C: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 15) MDP (psf) Type Fasteners (Note 11) Attach Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply CONVENTIONAL SYSTEMS: W-18. Min. 19/32- inch plywood or 1-inch wood plank; 2 ft span GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth Note 2 12-inch o.c. at the min. 4-inch lap and 12-inch o.c. in two, equally spaced, staggered center rows Min. 1-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation or EnergyGuard RH Polyiso or min. 1.5- inch EnergyGuard RA or EnergyGuard RN Hot asphalt Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation or EnergyGuard Perlite Recover Board or Min. 0.75- inch EnergyGuard Perlite Roof Insulation (homogeneous) Hot asphalt BP-AA, SBS- AA (Optional) BP-AA, SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -45.0 W-19. Min. 19/32- inch plywood or 1-inch wood plank; 2 ft span GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth Note 2 12-inch o.c. at the min. 4-inch lap and 12-inch o.c. in two, equally spaced, staggered center rows Min. 1-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation or EnergyGuard RH Polyiso or min. 1.5- inch EnergyGuard RA or EnergyGuard RN Hot asphalt Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Hot asphalt BP-AA, SBS- AA, SBS-TA, APP-TA (Optional) BP-AA, SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -45.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R35 for FL5680-R35 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 35: 04/11/2022 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 11 of 96 TABLE 1C: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 15) MDP (psf) Type Fasteners (Note 11) Attach Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply W-20. Min. 15/32- inch plywood or 1-inch wood plank; 2 ft span GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth Note 2 (#14 ONLY) 16-inch o.c. at the min. 4-inch lap and 16-inch o.c. in two, equally spaced, staggered center rows Min. 1-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation or EnergyGuard RH Polyiso or min. 1.5- inch EnergyGuard RA or EnergyGuard RN Hot asphalt Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation or EnergyGuard Perlite Recover Board or Min. 0.75- inch EnergyGuard Perlite Roof Insulation (homogeneous) Hot asphalt BP-AA, SBS- AA (Optional) BP-AA, SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -52.5 W-21. Min. 15/32- inch plywood or 1-inch wood plank; 2 ft span GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth Note 2 (#14 ONLY) 16-inch o.c. at the min. 4-inch lap and 16-inch o.c. in two, equally spaced, staggered center rows Min. 1-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation or EnergyGuard RH Polyiso or min. 1.5- inch EnergyGuard RA or EnergyGuard RN Hot asphalt Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Hot asphalt BP-AA, SBS- AA, SBS-TA, APP-TA (Optional) BP-AA, SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -52.5 W-22. Min. 15/32- inch plywood or 1-inch wood plank; 2 ft span GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth Note 2 (#14 ONLY) 12-inch o.c. at the min. 4-inch lap and 12-inch o.c. in two, equally spaced, staggered center rows Min. 1-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation or EnergyGuard RH Polyiso or min. 1.5- inch EnergyGuard RA or EnergyGuard RN Hot asphalt Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation or EnergyGuard Perlite Recover Board or Min. 0.75- inch EnergyGuard Perlite Roof Insulation (homogeneous) Hot asphalt BP-AA, SBS- AA (Optional) BP-AA, SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -60.0 W-23. Min. 15/32- inch plywood or 1-inch wood plank; 2 ft span GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth Note 2 (#14 ONLY) 12-inch o.c. at the min. 4-inch lap and 12-inch o.c. in two, equally spaced, staggered center rows Min. 1-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation or EnergyGuard RH Polyiso or min. 1.5- inch EnergyGuard RA or EnergyGuard RN Hot asphalt Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Hot asphalt BP-AA, SBS- AA, SBS-TA, APP-TA (Optional) BP-AA, SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -60.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R35 for FL5680-R35 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 35: 04/11/2022 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 12 of 96 TABLE 1C: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 15) MDP (psf) Type Fasteners (Note 11) Attach Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply W-24. Min. 19/32- inch plywood or 1-inch wood plank; 2 ft span GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth Note 2 12-inch o.c. at the min. 2-inch lap and 12-inch o.c. in three, equally spaced, staggered center rows Min. 1-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation or EnergyGuard RH Polyiso or min. 1.5- inch EnergyGuard RA or EnergyGuard RN Hot asphalt Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation or EnergyGuard Perlite Recover Board or Min. 0.75- inch EnergyGuard Perlite Roof Insulation (homogeneous) Hot asphalt BP-AA, SBS- AA (Optional) BP-AA, SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -60.0 W-25. Min. 19/32- inch plywood or 1-inch wood plank; 2 ft span GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth Note 2 12-inch o.c. at the min. 2-inch lap and 12-inch o.c. in three, equally spaced, staggered center rows Min. 1-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation or EnergyGuard RH Polyiso or min. 1.5- inch EnergyGuard RA or EnergyGuard RN Hot asphalt Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Hot asphalt BP-AA, SBS- AA, SBS-TA, APP-TA (Optional) BP-AA, SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -60.0 W-26. Min. 15/32- inch plywood or 1-inch wood plank; 2 ft span GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth Drill-Tec 3” Ribbed Galvalume Plate (Flat) with Drill- Tec #14 Fasteners or Drill-Tec #14 HD Fastener with Drill- Tec 3” Flat Steel Plate 12-inch o.c. at the min. 4-inch lap and 12-inch o.c. in two (2), equally spaced, staggered center rows Min. 1-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation or EnergyGuard RH Polyiso or min. 1.5- inch EnergyGuard RA or EnergyGuard RN Hot asphalt Min. 0.75-inch EnergyGuard Perlite Insulation Hot asphalt BP-AA, SBS- AA (Optional) BP-AA, SBS-AA SBS-AA -67.5* W-27. Min. 15/32- inch plywood or 1-inch wood plank; 2 ft span GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth Note 2 (#14 ONLY) 8-inch o.c. at the 4-inch lap and 8- inch o.c. in three staggered center rows Min. 1-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation or EnergyGuard RH Polyiso or min. 1.5- inch EnergyGuard RA or EnergyGuard RN Hot asphalt Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation or EnergyGuard Perlite Recover Board or Min. 0.75- inch EnergyGuard Perlite Roof Insulation (homogeneous) Hot asphalt BP-AA, SBS- AA (Optional) BP-AA, SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -75.0* NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R35 for FL5680-R35 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 35: 04/11/2022 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 13 of 96 TABLE 1C: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 15) MDP (psf) Type Fasteners (Note 11) Attach Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply W-28. Min. 15/32- inch plywood or 1-inch wood plank; 2 ft span GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth Note 2 (#14 ONLY) 8-inch o.c. at the 4-inch lap and 8- inch o.c. in three staggered center rows Min. 1-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation or EnergyGuard RH Polyiso or min. 1.5- inch EnergyGuard RA or EnergyGuard RN Hot asphalt Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Hot asphalt BP-AA, SBS- AA, SBS-TA, APP-TA (Optional) BP-AA, SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -82.5 VENTING SYSTEMS: W-29. Min. 15/32- inch plywood or 1-inch wood plank; 2 ft span GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth Note 2 (#14 ONLY) 16-inch o.c. at the min. 4-inch lap and 16-inch o.c. in two, equally spaced, staggered center rows Min. 1-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation or EnergyGuard RH Polyiso Hot asphalt (Optional) Additional layer(s) base insulation Hot asphalt GAFGLAS Stratavent Perforated Venting Base Sheet One or more BP- AA, SBS- AA SBS-AA, SBS-TA, APP-TA -52.5 W-30. Min. 15/32- inch plywood or 1-inch wood plank; 2 ft span GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth Note 2 (#14 ONLY) 12-inch o.c. at the min. 4-inch lap and 12-inch o.c. in two, equally spaced, staggered center rows Min. 1-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation or EnergyGuard RH Polyiso Hot asphalt (Optional) Additional layer(s) base insulation Hot asphalt GAFGLAS Stratavent Perforated Venting Base Sheet One or more BP- AA, SBS- AA SBS-AA, SBS-TA, APP-TA -60.0 W-31. Min. 15/32- inch plywood or 1-inch wood plank; 2 ft span GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth Note 2 (#14 ONLY) 8-inch o.c. at the 4-inch lap and 8- inch o.c. in three staggered center rows Min. 1-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation or EnergyGuard RH Polyiso Hot asphalt (Optional) Additional layer(s) base insulation Hot asphalt GAFGLAS Stratavent Perforated Venting Base Sheet One or more BP- AA, SBS- AA SBS-AA, SBS-TA, APP-TA -82.5* NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R35 for FL5680-R35 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 35: 04/11/2022 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 14 of 96 TABLE 1D: WOOD DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE B-1: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Fasteners (Note 11) Attach Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply W-32. Min. 19/32-inch plywood or 1-inch wood plank; 2 ft span Min. 1-inch EnergyGuard RN Drill-Tec #12 Fastener with Drill-Tec AccuTrac Flat Plate or AccuTrac Recessed Plate 1 per 1.8 ft2 Min. 0.25-inch SECUROCK Ultralight Coated Glass-Mat Roof Board OB500 SBS-SA (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -37.5 W-33. Min. 19/32-inch plywood or 1-inch wood plank; 2 ft span Min. 1-inch EnergyGuard Polyiso Insulation or EnergyGuard Ultra Polyiso Insulation Drill-Tec #12 Fastener with Drill-Tec 3” Steel Plate 1 per 1.8 ft2 Optional additional layer(s), min. 1.5- inch EnergyGuard Polyiso Insulation or EnergyGuard Ultra Polyiso Insulation followed by Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board LRF-XF SBS-SA (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -52.5 W-34. Min. 19/32-inch plywood or 1-inch wood plank; 2 ft span Min. 1-inch EnergyGuard RN Drill-Tec #12 Fastener with Drill-Tec AccuTrac Flat Plate or AccuTrac Recessed Plate 1 per 1.8 ft2 Min. 0.25-inch SECUROCK Gypsum- Fiber Roof Board OB500 SBS-SA (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -52.5 TABLE 1E: WOOD DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer (Note 13) Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Fasteners (Note 11) Attach Base Ply Ply Cap Ply CONVENTIONAL SYSTEMS: W-35. Min. 19/32-inch plywood or 1-inch wood plank; 2 ft span Min. 0.75-inch, one or more layers, any combination, loose laid Min. 1.5-inch EnergyGuard Composite or EnergyGuard RA Composite Note 2 1 per 3.0 ft2 BP-AA, SBS-AA (Optional) BP- AA, SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -45.0 W-36. Min. 19/32-inch plywood or 1-inch wood plank; 2 ft span Min. 0.75-inch, one or more layers, any combination, loose laid Min. 1-inch Structodek High Density Fiberboard Roof Insulation or min. 0.75-inch EnergyGuard Perlite Roof Insulation (homogeneous) Note 2 1 per 2.0 ft2 BP-AA, SBS-AA (Optional) BP- AA, SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -45.0 W-37. Min. 19/32-inch plywood or 1-inch wood plank; 2 ft span (Optional) One or more layers, any combination, loose laid Min. 0.25-inch SECUROCK Gypsum Fiber Roof Board Note 2 (#14 only) 1 per 1.8 ft2 BP-AA, SBS- AA, SBS-TA, APP-TA (Optional) BP- AA, SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -60.0 SELF-ADHERING BASE PLY: W-38. Min. 15/32-inch plywood or 1-inch wood plank; 2 ft span (Optional) One or more layers, any combination, loose laid Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Note 2 (#14 Fasteners only) 1 per 2.0 ft2 SBS-SA (Optional) SBS- SA SBS-SA -45.0 W-39. Min. 15/32-inch plywood or 1-inch wood plank; 2 ft span (Optional) One or more layers, any combination, loose laid Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Drill-Tec #12 Fasteners and Drill-Tec 3” Steel Plates 1 per 1.8 ft2 SBS-SA (Optional) SBS- TA, APP-TA SBS-TA, APP-TA -52.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R35 for FL5680-R35 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 35: 04/11/2022 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 15 of 96 TABLE 1E: WOOD DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer (Note 13) Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Fasteners (Note 11) Attach Base Ply Ply Cap Ply W-40. Min. 15/32-inch plywood or 1-inch wood plank; 2 ft span (Optional) One or more layers, any combination, loose laid Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Drill-Tec #12 Fasteners and Drill-Tec 3” Steel Plates 1 per 1.6 ft2 SBS-SA (Optional) SBS- TA, APP-TA SBS-TA, APP-TA -60.0 VENTING SYSTEMS: W-41. Min. 15/32-inch plywood or 1-inch wood plank; 2 ft span (Optional) One or more layers, any combination, loose laid Min. 1.5-inch EnergyGuard Polyiso Insulation or EnergyGuard Ultra Note 2 1 per 1.3 ft2 GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS-AA SBS-AA -60.0* COLD-APPLIED SYSTEMS: W-42. Min. 15/32-inch plywood or 1-inch wood plank; 2 ft span (Optional) One or more layers, any combination, loose laid Min. 0.25-inch SECUROCK Gypsum Fiber Roof Board Note 2 (#14 fasteners only) 1 per 2.0 ft2 SBS-CA1 None SBS-CA1 -45.0* W-43. Min. 15/32-inch plywood or 1-inch wood plank; 2 ft span (Optional) One or more layers, any combination, loose laid Min. 0.25-inch SECUROCK Gypsum Fiber Roof Board Note 2 (#14 fasteners only) 1 per 1.8 ft2 SBS-CA1 None SBS-CA1 -60.0 W-44. Min. 15/32-inch plywood or 1-inch wood plank; 2 ft span (Optional) One or more layers, any combination, loose laid Min. 0.25-inch SECUROCK Gypsum Fiber Roof Board Note 2 (#14 fasteners only) 1 per 1.3 ft2 SBS-CA1 None SBS-CA1 -82.5 © @ T® @ @ 1:. @ l ,--i ~ 1-•--I I-" @ T@ 1-9 @ @ © 1@ I-~ --I ~ ® @ ~@ ® @ l ~ I--i @ © @ .L@ ® @ ~ ~ ---1 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R35 for FL5680-R35 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 35: 04/11/2022 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 16 of 96 TABLE 1F: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE D-2: INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Insulation Layer(s) (Note 13) Base Sheet Roof Cover (Note 15) MDP (psf) Type Attach Type Fasteners (Note 11) Attach Base Ply Ply Cap Ply CONVENTIONAL SYSTEMS: W-45. Min. 19/32-inch plywood or 1-inch wood plank; 2 ft span Min. 1-inch, one or more layers, any combination Prelim attach GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, #80 Ultima Base Sheet, Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth Note 2 12-inch o.c. at min. 2-inch laps and 12-inch o.c. in two, equally spaced, staggered center rows BP-AA, SBS- AA (Optional) BP-AA, SBS- AA SBS-AA, SBS-TA, SBS-CA, APP-TA -45.0 W-46. Min. 19/32-inch plywood or 1-inch wood plank; 2 ft span Min. 1-inch, one or more layers, any combination Prelim attach GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, #80 Ultima Base Sheet, Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth Note 2 12-inch o.c. at min. 2-inch laps and 12-inch o.c. in three, equally spaced, staggered center rows BP-AA, SBS- AA (Optional) BP-AA, SBS- AA SBS-AA, SBS-TA, SBS-CA, APP-TA -60.0 W-47. Min. 19/32-inch plywood or 1-inch wood plank; 2 ft span Min. 1-inch, one or more layers, any combination Prelim attach GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, #80 Ultima Base Sheet, Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth Note 2 8-inch o.c. at min. 2-inch laps and 8-inch o.c. in three, equally spaced, staggered center rows BP-AA, SBS- AA (Optional) BP-AA, SBS- AA SBS-AA, SBS-TA, SBS-CA, APP-TA -75.0 SELF-ADHERING BASE PLY: W-48. Min. 15/32-inch plywood or 1-inch wood plank; 2 ft span Min. 1-inch, one or more layers, any combination Loose laid Liberty SBS Mechanically Attached Base Sheet Note 2 8-inch o.c. at min. 3-inch laps and 8-inch o.c. at two, equally spaced, staggered center rows SBS-SA None SBS-SA -97.5 TABLE 1G: WOOD DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE E-2: NON-INSULATED, MECHANICALY FASTEDED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Base Sheet Roof Cover (Note 15) MDP (psf) Type Fastener (Note 11) Attachment Base Ply Cap Ply CONVENTIONAL SYSTEMS: W-49. Min. 15/32-inch plywood or 1-inch wood plank; 2 ft span GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth 32 ga., 1-5/8-inch dia. tin caps with 11 ga. annular ring shank nails 8-inch o.c. at min. 4-inch laps and 8- inch o.c. in two, equally spaced, staggered center rows (Optional) BP- AA, SBS-AA SBS-AA -45.0 W-50. Min. 19/32-inch plywood or 1-inch wood plank; 2 ft span GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Eliminator Nailable Venting Base Sheet, Ruberoid 20 Smooth, Ruberoid Mop Smooth, Ruberoid Mop Smooth 1.5 32 ga., 1-5/8-inch dia. tin caps with 12 ga. annular ring shank nails 9-inch o.c. at min. 4-inch laps and 9- inch o.c. at two, equally spaced, staggered center rows (Optional) BP- AA, SBS-AA SBS-AA -45.0 W-51. Min. 19/32-inch plywood or 1-inch wood plank; 2 ft span GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth 32 ga., 1-5/8-inch dia. tin caps with 11 ga. annular ring shank nails 9-inch o.c. at min. 4-inch laps and 12- inch o.c. in two, equally spaced, staggered center rows BP-AA, SBS-AA SBS-AA, SBS-TA, SBS-CA, APP-TA -45.0 W-52. Min. 15/32-inch plywood or 1-inch wood plank; 2 ft span GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth 32 ga., 1-5/8-inch dia. tin caps with 11 ga. annular ring shank nails 6-inch o.c. at min. 4-inch laps and 6- inch o.c. in two, equally spaced, staggered center rows (Optional) BP- AA, SBS-AA SBS-AA -52.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R35 for FL5680-R35 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 35: 04/11/2022 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 17 of 96 TABLE 1G: WOOD DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE E-2: NON-INSULATED, MECHANICALY FASTEDED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Base Sheet Roof Cover (Note 15) MDP (psf) Type Fastener (Note 11) Attachment Base Ply Cap Ply W-53. Min. 19/32-inch plywood or 1-inch wood plank; 2 ft span GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth 32 ga., 1-5/8-inch dia. tin caps with 11 ga. annular ring shank nails 9-inch o.c. at min. 4-inch laps and 9- inch o.c. in two, equally spaced, staggered center rows BP-AA, SBS-AA SBS-AA, SBS-TA, SBS-CA, APP-TA -52.5 W-54. Min. 19/32-inch plywood or 1-inch wood plank; 2 ft span GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Eliminator Nailable Venting Base Sheet, Ruberoid 20 Smooth, Ruberoid Mop Smooth, Ruberoid Mop Smooth 1.5 32 ga., 1-5/8-inch dia. tin caps with 11 ga. annular ring shank nails 9-inch o.c. at min. 4-inch laps and 9- inch o.c. in two, equally spaced, staggered center rows (Optional) APP- TA APP-TA -60.0 W-55. Min. 19/32-inch plywood or 1-inch wood plank; 2 ft span GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Eliminator Nailable Venting Base Sheet, Ruberoid 20 Smooth, Ruberoid Mop Smooth, Ruberoid Mop Smooth 1.5 32 ga., 1-5/8-inch dia. tin caps with 12 ga. annular ring shank nails 8-inch o.c. at min. 4-inch laps and 8- inch o.c. at three, equally spaced, staggered center rows (Optional) BP- AA, SBS-AA SBS-AA -75.0 W-56. Min. 19/32-inch plywood or 1-inch wood plank; 2 ft span GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Eliminator Nailable Venting Base Sheet, Ruberoid 20 Smooth, Ruberoid Mop Smooth, Ruberoid Mop Smooth 1.5 32 ga., 1-5/8-inch dia. tin caps with 11 ga. annular ring shank nails 7-inch o.c. at min. 4-inch laps and 7- inch o.c. in three, equally spaced, staggered center rows BP-AA, SBS-AA SBS-AA, SBS-TA, SBS-CA, APP-TA -82.5 W-57. Min. 19/32-inch plywood or 1-inch wood plank; 2 ft span GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth 32 ga., 1-5/8-inch dia. tin caps with 11 ga. annular ring shank nails 4-inch o.c. at min. 2-inch laps and 4- inch o.c. in four (4), equally spaced, staggered center rows (Optional) BP- AA, SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -97.5 W-58. Min. 19/32-inch plywood or 1-inch wood plank; 2 ft span GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth 32 ga., 1-5/8-inch dia. tin caps with 11 ga. annular ring shank nails 3-inch o.c. at min. 3-inch laps and 3- inch o.c. at five (5), equally spaced, staggered center rows. Base sheet and tin-caps shall be primed with Matrix 307 Premium Asphalt Primer prior to base ply installation (Optional) SBS- TA Ruberoid HW Plus Granule, Ruberoid HW Plus Granule FR, Ruberoid EnergyCap HW Plus Granule FR -120.0 SELF-ADHERING BASE PLY: W-59. Min. 19/32-inch plywood or 1-inch wood plank; 2 ft span Liberty SBS Mechanically Attached Base Sheet or Liberty SBS Self-Adhering Base/Ply Sheet 32 ga., 1-5/8-inch dia. tin caps with 11 ga. annular ring shank nails 9-inch o.c. at min. 4-inch laps and 9- inch o.c. in two, equally spaced, staggered center rows (Optional) SBS- SA SBS-SA, SBS-TA or APP-TA -37.5 W-60. Min. 15/32-inch plywood or 1-inch wood plank; 2 ft span Liberty SBS Mechanically Attached Base Sheet or Liberty SBS Self-Adhering Base/Ply Sheet 32 ga., 1-5/8-inch dia. tin caps with 11 ga. annular ring shank nails 8-inch o.c. at min. 3-inch laps and 8- inch o.c. in three, equally spaced, staggered center rows (Optional) SBS- SA SBS-SA, SBS-TA or APP-TA -45.0 TABLE 1H: WOOD DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE E-2: NON-INSULATED, MECHANICALY FASTEDED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Base Sheet Roof Cover (Note 15) MDP (psf) Type Fastener (Note 11) Attachment Base Ply Cap Ply CONVENTIONAL SYSTEMS: W-61. Min. 19/32-inch plywood or 1-inch wood plank; 2 ft span GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth Note 2 12-inch o.c. at 2-inch laps and 12- inch o.c. in two, equally spaced, staggered center rows BP-AA, SBS- AA SBS-AA, SBS-TA, SBS-CA, APP-TA -45.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R35 for FL5680-R35 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 35: 04/11/2022 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 18 of 96 TABLE 1H: WOOD DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE E-2: NON-INSULATED, MECHANICALY FASTEDED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Base Sheet Roof Cover (Note 15) MDP (psf) Type Fastener (Note 11) Attachment Base Ply Cap Ply W-62. Min. 15/32-inch plywood or 1-inch wood plank; 2 ft span GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth Note 2 (#14 ONLY) 16-inch o.c. at 4-inch laps and 16- inch o.c. in two, equally spaced, staggered center rows (Optional) BP-AA, SBS- AA SBS-AA -52.5 W-63. Min. 15/32-inch plywood or 1-inch wood plank; 2 ft span GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth Note 2 (#14 ONLY) 12-inch o.c. at 4-inch laps and 12- inch o.c. in two, equally spaced, staggered center rows (Optional) BP-AA, SBS- AA SBS-AA -60.0 W-64. Min. 19/32-inch plywood or 1-inch wood plank; 2 ft span GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth Note 2 12-inch o.c. at 2-inch laps and 12- inch o.c. in three, equally spaced, staggered center rows BP-AA, SBS- AA SBS-AA, SBS-TA, SBS-CA, APP-TA -60.0 W-65. Min. 19/32-inch plywood or 1-inch wood plank; 2 ft span GAFGLAS #80 Ultima Base Sheet, Ruberoid 20 Smooth, Ruberoid Mop Smooth, Ruberoid Mop Smooth 1.5 Note 2 9-inch o.c. at 4-inch laps and 9-inch o.c. in two, equally spaced, staggered center rows (Optional) SBS-TA SBS-TA (polyester only) -60.0 W-66. Min. 15/32-inch plywood or 1-inch wood plank; 2 ft span GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth Note 2 (#14 ONLY) 8-inch o.c. at 4-inch laps and 8-inch o.c. in three, equally spaced, staggered center rows (Optional) BP-AA, SBS- AA SBS-AA -97.5 W-67. Min. 19/32-inch plywood or 1-inch wood plank; 2 ft span GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth Note 2 8-inch o.c. at 2-inch laps and 8-inch o.c. in three, equally spaced, staggered center rows BP-AA, SBS- AA SBS-AA, SBS-TA, SBS-CA, APP-TA -105.0 SELF-ADHERING BASE PLY: W-68. Min. 19/32-inch plywood or 1-inch wood plank; 2 ft span StormSafe Anchor Sheet Note 2 (Drill-Tec AccuTrac Flat Plate, Drill-Tec 3” Flat Steel Plate or Drill-Tec 3” Recessed Steel Plate only) 9-inch o.c. at 4-inch laps and 9-inch o.c. in three, equally spaced, staggered center rows (Optional) SBS-SA SBS-SA Note: Seams sealed with TOPCOAT SB900 or Flexseal -60.0 W-69. Min. 15/32-inch plywood or 1-inch wood plank; 2 ft span Liberty SBS Mechanically Attached Base Sheet Note 2 (HD Fasteners only) 8-inch o.c. at 3-inch laps and 8-inch o.c. in two, equally spaced, staggered center rows (Optional) SBS-SA SBS-SA, SBS-TA or APP- TA -60.0 TABLE 1I: WOOD DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE F: NON-INSULATED, BONDED ROOF COVER System No. Deck (Note 1) Primer Roof Cover (Note 15) MDP (psf) Base Ply Cap Ply W-70. Min. 7/16-inch APA rated OSB; 2 ft span, 8d ring shank nails, 6” o.c. Matrix 307 Premium Asphalt Primer at 0.5 gal/square None SBS-SA -67.5 W-71. Min. 15/32-inch plywood or 1-inch wood plank; 2 ft span, 8d rink shank nails, 6” o.c. Matrix 307 Premium Asphalt Primer at 1.0 gal/square None SBS-SA -75.0 W-72. Min. 15/32-inch APA rated plywood; 2 ft span, 8d rink shank nails, 6” o.c. Matrix 307 Premium Asphalt Primer at 0.5 gal/square SBS-SA SBS-SA -82.5 W-73. Min. 15/32-inch plywood or 1-inch wood plank; 2 ft span, #8 x 2½” deck screws, 6” o.c. Matrix 307 Premium Asphalt Primer at 1.0 gal/square None SBS-SA -90.0 W-74. Min. 15/32-inch plywood or 1-inch wood plank; 2 ft span, 8d rink shank nails, 6” o.c. Matrix 307 Premium Asphalt Primer at 1.0 gal/square SBS-SA SBS-SA -90.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R35 for FL5680-R35 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 35: 04/11/2022 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 19 of 96 TABLE 2A: STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE B-1: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Fasten (Note 11) Attach Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply CONVENTIONAL SYSTEMS: SC-1 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Note 2 1 per 4.0 ft2 Optional additional layers, min. 1.5-inch base insulation followed by min. 0.75-inch EnergyGuard Perlite Roof Insulation (homogeneous) or min. 0.5-inch Structodek High Density Fiberboard Roof Insulation or EnergyGuard Perlite Recover Board or min. 0.25-inch DensDeck, DensDeck Prime or SECUROCK Gypsum Fiber Roof Board Hot asphalt BP-AA, SBS-AA (Optional) One or more BP-AA, SBS- AA SBS-AA -37.5* SC-2 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 0.625-inch DensDeck Prime Note 2 1 per 4.0 ft2 Min. 1.5-inch EnergyGuard followed by min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Hot asphalt APP-TA (Optional) APP-TA APP-TA -45.0* SC-3 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 0.5-inch DensDeck Prime Note 2 1 per 2.7 ft2 Min. 1.5-inch EnergyGuard followed by min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Hot asphalt APP-TA (Optional) APP-TA APP-TA -45.0* SC-4 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Note 2 1 per 2.7 ft2 Optional additional layers, min. 1.5-inch base insulation followed by min. 0.75-inch EnergyGuard Perlite Roof Insulation (homogeneous) or min. 0.5-inch Structodek High Density Fiberboard Roof Insulation or EnergyGuard Perlite Recover Board or min. 0.25-inch DensDeck, DensDeck Prime or SECUROCK Gypsum Fiber Roof Board Hot asphalt BP-AA, SBS-AA (Optional) One or more BP-AA, SBS- AA SBS-AA -45.0* SC-5 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Note 2 1 per 2.0 ft2 Optional additional layers, min. 1.5-inch base insulation followed by min. 0.75-inch EnergyGuard Perlite Roof Insulation (homogeneous) or min. 0.5-inch Structodek High Density Fiberboard Roof Insulation or EnergyGuard Perlite Recover Board or min. 0.25-inch DensDeck, DensDeck Prime or SECUROCK Gypsum Fiber Roof Board Hot asphalt BP-AA, SBS-AA (Optional) One or more BP-AA, SBS- AA SBS-AA -45.0* SC-6 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Note 2 1 per 4.0 ft2 Optional additional layers, min. 1.5-inch base insulation followed by min. 0.75-inch EnergyGuard Perlite Roof Insulation (homogeneous) or min. 0.5-inch Structodek High Density Fiberboard Roof Insulation or EnergyGuard Perlite Recover Board or min. 0.25-inch DensDeck, DensDeck Prime or SECUROCK Gypsum Fiber Roof Board Hot asphalt BP-AA, SBS-AA (Optional) One or more BP-AA, SBS- AA SBS-AA -45.0* NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R35 for FL5680-R35 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 35: 04/11/2022 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 20 of 96 TABLE 2A: STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE B-1: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Fasten (Note 11) Attach Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply SC-7 Min. 22 ga., type B, Grade 50 steel or min. 2,500 psi structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation or EnergyGuard Ultra Note 2 1 per 1.8 ft2 Min. 0.75-inch EnergyGuard Perlite Roof Insulation (homogeneous), min. 0.5-inch Structodek High Density Fiberboard Roof Insulation or EnergyGuard Perlite Recover Board or min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Hot asphalt BP-AA, SBS-AA (Optional) BP-AA, SBS- AA SBS-AA -60.0* SC-8 Min. 22 ga., type B, Grade 50 steel or min. 2,500 psi structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation or EnergyGuard Ultra Note 2 1 per 1.8 ft2 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Hot asphalt SBS-TA or APP-TA (Optional) SBS-TA or APP-TA SBS-TA or APP-TA -60.0* SC-9 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Note 2 1 per 1.45 ft2 Min. 1.0-inch EnergyGuard Perlite Roof Insulation (homogeneous) Hot asphalt BP-AA, SBS-AA (Optional) BP-AA, SBS- AA SBS-AA or SBS-TA -60.0 SC-10 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation, EnergyGuard RH, EnergyGuard RN Note 2 1 per 1.3 ft2 Optional additional layers base insulation followed by min. 0.75-inch EnergyGuard Perlite Roof Insulation (homogeneous), min. 0.5-inch Structodek High Density Fiberboard Roof Insulation or EnergyGuard Perlite Recover Board, min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Hot asphalt BP-AA or SBS-AA (Optional) BP-AA, SBS- AA, SBS-TA SBS-AA, SBS-TA -60.0 SC-11 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Note 2 1 per 1.45 ft2 Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation Hot asphalt BP-AA, SBS-AA (Optional) BP-AA, SBS- AA SBS-AA or SBS-TA -67.5 SC-12 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Note 2 1 per 2.0 ft2 Optional additional layer(s) min. 1.5-inch thick base insulation followed by Min. 0.25-inch DensDeck, DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Hot asphalt or OB500 BP-AA, SBS-AA, SBS-TA or APP-TA (Optional) One or more BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -45.0* SC-13 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Note 2 1 per 4.0 ft2 Optional additional layer(s) min. 1.5-inch thick base insulation followed by Min. 0.25-inch DensDeck, DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Hot asphalt or OB500 BP-AA, SBS-AA, SBS-TA or APP-TA (Optional) One or more BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -45.0* NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R35 for FL5680-R35 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 35: 04/11/2022 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 21 of 96 TABLE 2A: STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE B-1: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Fasten (Note 11) Attach Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply SC-14 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Note 2 1 per 2.0 ft2 Optional additional layer(s) min. 1.5-inch thick base insulation followed by Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation Hot asphalt or OB500 BP-AA, SBS-AA None SBS-CA -45.0* SC-15 Min. 22 ga., type B, Grade 50 steel or min. 2,500 psi structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation or EnergyGuard Ultra Note 2 1 per 1.8 ft2 Optional additional layer(s) min. 1.5-inch thick EnergyGuard Polyiso Insulation or EnergyGuard Ultra Polyiso Insulation followed by Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 SBS-TA or APP-TA (Optional) SBS-TA or APP-TA SBS-TA or APP-TA -52.5 SC-16 Min. 22 ga., type B, Grade 50 steel or min. 2,500 psi structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation or EnergyGuard Ultra Note 2 1 per 1.8 ft2 Optional additional layer(s) min. 1.5-inch thick EnergyGuard Polyiso Insulation or EnergyGuard Ultra Polyiso Insulation followed by Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-AA -52.5 SC-17 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Note 2 1 per 1.6 ft2 Optional additional layer(s) min. 1.5-inch thick EnergyGuard Polyiso Insulation or EnergyGuard Ultra Polyiso Insulation followed by Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Hot asphalt or OB500 BP-AA, SBS-AA, SBS-TA or APP-TA (Optional) One or more BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -60.0 SC-18 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra, EnergyGuard RA, EnergyGuard RH Note 2 1 per 2.0 ft2 Optional additional layer(s) min. 1.5-inch thick base insulation followed by Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-XF BP-AA, SBS-AA, SBS-TA or APP-TA (Optional) One or more BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -45.0* SC-19 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra, EnergyGuard RA, EnergyGuard RH Note 2 1 per 4.0 ft2 Optional additional layer(s) min. 1.5-inch thick base insulation followed by Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-XF BP-AA, SBS-AA, SBS-TA or APP-TA (Optional) One or more BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -45.0* SC-20 Min. 22 ga., type B, Grade 50 steel or min. 2,500 psi structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation or EnergyGuard Ultra Note 2 1 per 1.8 ft2 Optional additional layer(s) min. 1.5-inch thick EnergyGuard Polyiso Insulation or EnergyGuard Ultra Polyiso Insulation followed by Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-XF SBS-TA or APP-TA (Optional) SBS-TA or APP-TA SBS-TA or APP-TA -52.5 SC-21 Min. 22 ga., type B, Grade 50 steel or min. 2,500 psi structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation or EnergyGuard Ultra Note 2 1 per 1.8 ft2 Optional additional layer(s) min. 1.5-inch thick EnergyGuard Polyiso Insulation or EnergyGuard Ultra Polyiso Insulation followed by Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-XF BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-AA -52.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R35 for FL5680-R35 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 35: 04/11/2022 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 22 of 96 TABLE 2A: STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE B-1: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Fasten (Note 11) Attach Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply SC-22 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra, EnergyGuard RA, EnergyGuard RH Note 2 1 per 1.6 ft2 Optional additional layer(s) min. 1.5-inch thick EnergyGuard Polyiso Insulation or EnergyGuard Ultra Polyiso Insulation followed by Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board LRF-XF BP-AA, SBS-AA, SBS-TA or APP-TA (Optional) One or more BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -60.0 SELF-ADHERING BASE PLY: SC-23 Min. 22 ga., Type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 1.5-EnergyGuard RH, EnergyGuard Polyiso Insulation, EnergyGuard Ultra Note 2 1 per 2.0 ft2 Optional additional layer(s) min. 1.5-inch thick base insulation followed by Min. 0.5-inch EnergyGuard RH HD Polyiso Insulation, EnergyGuard HD Polyiso Cover Board, EnergyGuard HD Plus Polyiso Cover Board OB500, LRF-M, M- OSFA SBS-SA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -37.5* SC-24 Min. 22 ga., Type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 2-EnergyGuard RH, EnergyGuard Polyiso Insulation, EnergyGuard Ultra Note 2 1 per 2.9 ft2 Optional additional layer(s) min. 1.5-inch thick base insulation followed by Min. 0.5-inch EnergyGuard RH HD Polyiso Insulation, EnergyGuard HD Polyiso Cover Board, EnergyGuard HD Plus Polyiso Cover Board OB500, LRF-M, M- OSFA SBS-SA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -37.5* SC-25 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Note 2 1 per 2.0 ft2 Optional additional layer(s) min. 1.5-inch thick base insulation followed by Min. 0.25-inch SECUROCK Ultralight Coated Glass-Mat Roof Board OB500 SBS-SA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -37.5* SC-26 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 2-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Note 2 1 per 4.0 ft2 Optional additional layer(s) min. 1.5-inch thick base insulation followed by Min. 0.25-inch SECUROCK Ultralight Coated Glass-Mat Roof Board OB500 SBS-SA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -37.5* SC-27 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 2-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Note 2 1 per 4.0 ft2 Optional additional layer(s) min. 1.5-inch thick base insulation followed by Min. 0.25-inch SECUROCK Ultralight Coated Glass-Mat Roof Board OB500 SBS-SA (Optional) SBS-SA SBS-SA -37.5* SC-28 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Note 2 1 per 2.0 ft2 Optional additional layer(s) min. 0.5-inch thick base insulation followed by Min. 0.25-inch SECUROCK Ultralight Coated Glass-Mat Roof Board OB500, LRF-M, M- OSFA SBS-SA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -37.5* SC-29 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Note 2 1 per 2.9 ft2 Optional additional layer(s) min. 0.5-inch thick base insulation followed by Min. 0.25-inch SECUROCK Ultralight Coated Glass-Mat Roof Board OB500, LRF-M, M- OSFA SBS-SA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -37.5* NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R35 for FL5680-R35 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 35: 04/11/2022 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 23 of 96 TABLE 2A: STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE B-1: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Fasten (Note 11) Attach Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply SC-30 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Note 2 1 per 4.0 ft2 Optional additional layer(s) min. 0.5-inch thick base insulation followed by Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board OB500, LRF-M, M- OSFA SBS-SA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -37.5* SC-31 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Note 2 1 per 2.0 ft2 Additional layer(s), min. 0.5-inch thick base insulation OB500, LRF-M, M- OSFA SBS-SA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -45.0* SC-32 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Note 2 1 per 2.9 ft2 Additional layer(s), min. 0.5-inch thick base insulation OB500, LRF-M, M- OSFA SBS-SA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -45.0* SC-33 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Note 2 1 per 4.0 ft2 Additional layer(s), min. 1.5-inch thick base insulation OB500, LRF-M, M- OSFA SBS-SA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -45.0* SC-34 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Note 2 1 per 2.0 ft2 Optional additional layer(s) min. 1.5-inch thick base insulation followed by Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 SBS-SA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -45.0* SC-35 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Note 2 1 per 2.0 ft2 Optional additional layer(s) min. 0.5-inch thick base insulation followed by Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board OB500, LRF-M, M- OSFA SBS-SA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -45.0* SC-36 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Note 2 1 per 2.9 ft2 Optional additional layer(s) min. 0.5-inch thick base insulation followed by Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board OB500, LRF-M, M- OSFA SBS-SA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -45.0* SC-37 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 2-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Note 2 1 per 4.0 ft2 Optional additional layer(s) min. 1.5-inch thick base insulation followed by Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 SBS-SA (Optional) SBS-SA SBS-SA -45.0* SC-38 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 2-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Note 2 1 per 4.0 ft2 Optional additional layer(s) min. 1.5-inch thick base insulation followed by Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 SBS-SA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -45.0* NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R35 for FL5680-R35 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 35: 04/11/2022 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 24 of 96 TABLE 2A: STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE B-1: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Fasten (Note 11) Attach Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply SC-39 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Note 2 1 per 4.0 ft2 Optional additional layer(s) min. 0.5-inch thick base insulation followed by Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board OB500, LRF-M, M- OSFA SBS-SA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -45.0* SC-40 Min. 22 ga., type B, Grade 50 steel or min. 2,500 psi structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation or EnergyGuard Ultra Note 2 1 per 1.8 ft2 Optional additional layer(s) min. 1.5-inch thick EnergyGuard Polyiso Insulation or EnergyGuard Ultra Polyiso Insulation followed by Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 SBS-SA (Optional) SBS-TA SBS-TA -52.5 SC-41 Min. 22 ga., type B, Grade 50 steel or min. 2,500 psi structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation or EnergyGuard Ultra Note 2 1 per 1.8 ft2 Optional additional layer(s) min. 1.5-inch thick EnergyGuard Polyiso Insulation or EnergyGuard Ultra Polyiso Insulation followed by Min. 0.5-inch EnergyGuard HD Polyiso Cover Board, EnergyGuard HD Plus Polyiso Cover Board OB500 SBS-SA (Optional) SBS-TA SBS-TA -60.0 SC-42 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Note 2 1 per 1.6 ft2 Optional additional layer(s) min. 1.5-inch thick EnergyGuard Polyiso Insulation or EnergyGuard Ultra Polyiso Insulation followed by Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 SBS-SA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -60.0 SC-43 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Note 2 1 per 4.0 ft2 Optional additional layer(s) min. 1.5-inch thick base insulation followed by Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Hot asphalt SBS-SA (Optional) SBS-SA SBS-SA -45.0* SC-44 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Note 2 1 per 2.0 ft2 Optional additional layer(s) min. 1.5-inch thick base insulation followed by Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Hot asphalt SBS-SA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -45.0* SC-45 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Note 2 1 per 4.0 ft2 Optional additional layer(s) min. 1.5-inch thick base insulation followed by Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Hot asphalt SBS-SA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -45.0* SC-46 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Note 2 1 per 1.6 ft2 Optional additional layer(s) min. 1.5-inch thick EnergyGuard Polyiso Insulation or EnergyGuard Ultra Polyiso Insulation followed by Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Hot asphalt SBS-SA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -60.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R35 for FL5680-R35 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 35: 04/11/2022 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 25 of 96 TABLE 2A: STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE B-1: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Fasten (Note 11) Attach Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply SC-47 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Note 2 1 per 2.0 ft2 Additional layer(s), min. 0.5-inch thick base insulation LRF-XF SBS-SA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -45.0* SC-48 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Note 2 1 per 2.9 ft2 Additional layer(s), min. 0.5-inch thick base insulation LRF-XF SBS-SA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -45.0* SC-49 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Note 2 1 per 4.0 ft2 Additional layer(s), min. 1.5-inch thick base insulation LRF-XF SBS-SA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -45.0* SC-50 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH Note 2 1 per 2.0 ft2 Optional additional layer(s) min. 1.5-inch thick base insulation followed by Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-XF SBS-SA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -45.0* SC-51 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Note 2 1 per 2.0 ft2 Optional additional layer(s) min. 0.5-inch thick base insulation followed by Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-XF SBS-SA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -45.0* SC-52 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Note 2 1 per 2.9 ft2 Optional additional layer(s) min. 0.5-inch thick base insulation followed by Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-XF SBS-SA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -45.0* SC-53 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 2-inch EnergyGuard RA, EnergyGuard RH Note 2 1 per 4.0 ft2 Optional additional layer(s) min. 1.5-inch thick base insulation followed by Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board LRF-XF SBS-SA (Optional) SBS-SA SBS-SA -45.0* SC-54 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 2-inch EnergyGuard RA, EnergyGuard RH Note 2 1 per 4.0 ft2 Optional additional layer(s) min. 1.5-inch thick base insulation followed by Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-XF SBS-SA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -45.0* SC-55 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Note 2 1 per 4.0 ft2 Optional additional layer(s) min. 0.5-inch thick base insulation followed by Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-XF SBS-SA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -45.0* NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R35 for FL5680-R35 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 35: 04/11/2022 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 26 of 96 TABLE 2A: STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE B-1: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Fasten (Note 11) Attach Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply SC-56 Min. 22 ga., type B, Grade 50 steel or min. 2,500 psi structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation or EnergyGuard Ultra Note 2 1 per 1.8 ft2 Optional additional layer(s) min. 1.5-inch thick EnergyGuard Polyiso Insulation or EnergyGuard Ultra Polyiso Insulation followed by Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-XF SBS-SA (Optional) SBS-TA SBS-TA -52.5 SC-57 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra, EnergyGuard RA, EnergyGuard RH Note 2 1 per 1.6 ft2 Optional additional layer(s) min. 1.5-inch thick EnergyGuard Polyiso Insulation or EnergyGuard Ultra Polyiso Insulation followed by Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board LRF-XF SBS-SA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -60.0 VENTING SYSTEMS: SC-58 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Note 2 1 per 4.0 ft2 Additional layer(s) of base insulation Hot asphalt GAFGLAS Stratavent Perforate d Venting Base Sheet (Optional) One or more BP-AA, SBS- AA SBS-AA -45.0* COLD-APPLIED SYSTEMS: SC-59 Min. 22 ga., Type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra, EnergyGuard RH Note 2 1 per 2.0 ft2 Optional additional layer(s) min. 1.5-inch thick base insulation followed by Min. 0.5-inch EnergyGuard RH HD Polyiso Insulation, EnergyGuard HD Polyiso Cover Board, EnergyGuard HD Plus Polyiso Cover Board OB500, LRF-M, M- OSFA SBS-CA or SBS-CA1 None SBS-CA or SBS-CA1 -37.5* SC-60 Min. 22 ga., Type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra, EnergyGuard RH Note 2 1 per 2.9 ft2 Optional additional layer(s) min. 1.5-inch thick base insulation followed by Min. 0.5-inch EnergyGuard RH HD Polyiso Insulation, EnergyGuard HD Polyiso Cover Board, EnergyGuard HD Plus Polyiso Cover Board OB500, LRF-M, M- OSFA SBS-CA or SBS-CA1 None SBS-CA or SBS-CA1 -37.5* SC-61 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Note 2 1 per 2.0 ft2 Optional additional layer(s) min. 1.5-inch thick base insulation followed by Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 SBS-CA1 None SBS-CA1 -45.0* SC-62 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Note 2 1 per 4.0 ft2 Optional additional layer(s) min. 1.5-inch thick base insulation followed by Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 SBS-CA1 None SBS-CA1 -45.0* NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R35 for FL5680-R35 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 35: 04/11/2022 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 27 of 96 TABLE 2A: STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE B-1: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Fasten (Note 11) Attach Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply SC-63 Min. 22 ga., type B, Grade 50 steel or min. 2,500 psi structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation or EnergyGuard Ultra Note 2 1 per 1.8 ft2 Optional additional layer(s) min. 1.5-inch thick EnergyGuard Polyiso Insulation or EnergyGuard Ultra Polyiso Insulation followed by Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 SBS-CA1 None SBS-CA1 -52.5 SC-64 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra, EnergyGuard RA, EnergyGuard RH Note 2 1 per 2.0 ft2 Optional additional layer(s) min. 1.5-inch thick base insulation followed by Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-XF SBS-CA1 None SBS-CA1 -45.0* SC-65 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra, EnergyGuard RA, EnergyGuard RH Note 2 1 per 4.0 ft2 Optional additional layer(s) min. 1.5-inch thick base insulation followed by Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-XF SBS-CA1 None SBS-CA1 -45.0* SC-66 Min. 22 ga., type B, Grade 50 steel or min. 2,500 psi structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation or EnergyGuard Ultra Note 2 1 per 1.8 ft2 Optional additional layer(s) min. 1.5-inch thick EnergyGuard Polyiso Insulation or EnergyGuard Ultra Polyiso Insulation followed by Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-XF SBS-CA1 None SBS-CA1 -52.5 HYBRID HOT/COLD-APPLIED SYSTEMS: SC-67 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 1.5-inch EnergyGuard RH, EnergyGuard RN Note 2 1 per 2.0 ft2 Optional additional layers base insulation followed by min. 0.75-inch EnergyGuard Perlite Roof Insulation (homogeneous), min. 0.5-inch Structodek High Density Fiberboard Roof Insulation or EnergyGuard Perlite Recover Board, min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Hot asphalt BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -45.0* SC-68 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation Note 2 1 per 2.7 ft2 Optional additional layers base insulation followed by min. 0.75-inch EnergyGuard Perlite Roof Insulation (homogeneous) or min. 0.5-inch Structodek High Density Fiberboard Roof Insulation Hot asphalt BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -45.0* SC-69 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation Note 2 1 per 3.2 ft2 Optional additional layers base insulation followed by min.0.5-inch EnergyGuard Perlite Recover Board, min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Hot asphalt BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -45.0* NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R35 for FL5680-R35 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 35: 04/11/2022 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 28 of 96 TABLE 2A: STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE B-1: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Fasten (Note 11) Attach Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply SC-70 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation Note 2 1 per 4.0 ft2 Optional additional layers base insulation followed by min. 0.75-inch EnergyGuard Perlite Roof Insulation (homogeneous), min. 0.5-inch Structodek High Density Fiberboard Roof Insulation or EnergyGuard Perlite Recover Board, min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Hot asphalt BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -45.0* SC-71 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 2-inch EnergyGuard RH, EnergyGuard RN Note 2 1 per 3.2 ft2 Optional additional layers base insulation followed by min. 0.75-inch EnergyGuard Perlite Roof Insulation (homogeneous), min. 0.5-inch Structodek High Density Fiberboard Roof Insulation or EnergyGuard Perlite Recover Board, min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Hot asphalt BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -45.0* SC-72 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 2-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Note 2 1 per 4.0 ft2 Min. 0.25-inch DensDeck, DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Hot asphalt BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -45.0* SC-73 Min. 22 ga., type B, Grade 50 steel or min. 2,500 psi structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation or EnergyGuard Ultra Note 2 1 per 1.8 ft2 Min. 0.75-inch EnergyGuard Perlite Roof Insulation (homogeneous), min. 0.5-inch Structodek High Density Fiberboard Roof Insulation or EnergyGuard Perlite Recover Board or min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Hot asphalt BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -60.0* SC-74 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RH, EnergyGuard RN Note 2 1 per 1.3 ft2 Optional additional layers base insulation followed by min. 0.75-inch EnergyGuard Perlite Roof Insulation (homogeneous), min. 0.5-inch Structodek High Density Fiberboard Roof Insulation or EnergyGuard Perlite Recover Board, min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Hot asphalt BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -60.0 SC-75 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Note 2 1 per 2.0 ft2 Optional additional layer(s) min. 0.5-inch thick base insulation followed by min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -45.0* SC-76 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Note 2 1 per 4.0 ft2 Optional additional layer(s) min. 0.5-inch thick base insulation followed by min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -45.0* NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R35 for FL5680-R35 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 35: 04/11/2022 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 29 of 96 TABLE 2A: STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE B-1: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Fasten (Note 11) Attach Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply SC-77 Min. 22 ga., type B, Grade 50 steel or min. 2,500 psi structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation or EnergyGuard Ultra Note 2 1 per 1.8 ft2 Optional additional layer(s) min. 1.5-inch thick EnergyGuard Polyiso Insulation or EnergyGuard Ultra Polyiso Insulation followed by Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -52.5 SC-78 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra, EnergyGuard RA, EnergyGuard RH Note 2 1 per 2.0 ft2 Optional additional layer(s) min. 1.5-inch thick base insulation followed by Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-XF BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -45.0* SC-79 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra, EnergyGuard RA, EnergyGuard RH Note 2 1 per 4.0 ft2 Optional additional layer(s) min. 1.5-inch thick base insulation followed by Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-XF BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -45.0* SC-80 Min. 22 ga., type B, Grade 50 steel or min. 2,500 psi structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation or EnergyGuard Ultra Note 2 1 per 1.8 ft2 Optional additional layer(s) min. 1.5-inch thick EnergyGuard Polyiso Insulation or EnergyGuard Ultra Polyiso Insulation followed by Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-XF BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -52.5 TABLE 2B: STEEL DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) SYSTEM TYPE B-2: MECHANICALLY ATTACHED THERMAL BARRIER, BONDED TEMP ROOF, BONDED TOP INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Thermal Barrier Temp Roof Insulation Layer(s) Roof Cover (Note 15) MDP (psf) Type Fastener (Note 11) Attach Type Attach (Notes 6,7,8) Base Ply Cap CONVENTIONAL SYSTEMS: SC-81 Min. 22 ga., Type B, Grade 33 steel 0.5-inch DensDeck Prime or SECUROCK Gypsum Fiber Roof Board Note 2 (Drill-Tec 3 in. Ribbed Galvalume Plate (Flat) may be used) 1 per 4.0 ft2 Primer: GAF SA Primer or Matrix 307 Premium Asphalt Primer Vapor Retarder: GAF SA Vapor Retarder, self-adhering One or more layers, base layer min. 1-inch thick, optional subsequent layer(s) min. 1.5- inch thick EnergyGuard RN Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-M or OB500 SBS-TA or APP-TA (Optional) SBS-TA or APP-TA SBS-TA or APP- TA -45.0* SC-82 Min. 22 ga., Type B, Grade 33 steel 0.5-inch DensDeck Prime or SECUROCK Gypsum Fiber Roof Board Note 2 (Drill-Tec 3 in. Ribbed Galvalume Plate (Flat) may be used) 1 per 4.0 ft2 GAF SA Vapor Retarder XL, self-adhering One or more layers, base layer min. 1-inch thick, optional subsequent layer(s) min. 1.5- inch thick EnergyGuard RN Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-M or OB500 SBS-TA or APP-TA (Optional) SBS-TA or APP-TA SBS-TA or APP- TA -45.0* NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R35 for FL5680-R35 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 35: 04/11/2022 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 30 of 96 TABLE 2B: STEEL DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) SYSTEM TYPE B-2: MECHANICALLY ATTACHED THERMAL BARRIER, BONDED TEMP ROOF, BONDED TOP INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Thermal Barrier Temp Roof Insulation Layer(s) Roof Cover (Note 15) MDP (psf) Type Fastener (Note 11) Attach Type Attach (Notes 6,7,8) Base Ply Cap SC-83 Min. 22 ga., Type B, Grade 33 steel 0.5-inch DensDeck Prime or SECUROCK Gypsum Fiber Roof Board Note 2 (Drill-Tec 3 in. Ribbed Galvalume Plate (Flat) may be used) 1 per 4.0 ft2 Primer: GAF SA Primer or Matrix 307 Premium Asphalt Primer Vapor Retarder: GAF SA Vapor Retarder, self-adhering One or more layers, base layer min. 1-inch thick, optional subsequent layer(s) min. 1.5- inch thick EnergyGuard RN Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-M or OB500 BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-AA -45.0* SC-84 Min. 22 ga., Type B, Grade 33 steel 0.5-inch DensDeck Prime or SECUROCK Gypsum Fiber Roof Board Note 2 (Drill-Tec 3 in. Ribbed Galvalume Plate (Flat) may be used) 1 per 4.0 ft2 GAF SA Vapor Retarder XL, self-adhering One or more layers, base layer min. 1-inch thick, optional subsequent layer(s) min. 1.5- inch thick EnergyGuard RN Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-M or OB500 BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-AA -45.0* SC-85 Min. 22 ga., Type B, Grade 33 steel 0.5-inch DensDeck Prime or SECUROCK Gypsum Fiber Roof Board Note 2 (Drill-Tec 3 in. Ribbed Galvalume Plate (Flat) may be used) 1 per 4.0 ft2 Primer: GAF SA Primer or Matrix 307 Premium Asphalt Primer Vapor Retarder: GAF SA Vapor Retarder, self-adhering One or more layers, base layer min. 1-inch thick, optional subsequent layer(s) min. 1.5- inch thick EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-M, LRF- XF or OB500 SBS-TA or APP-TA (Optional) SBS-TA or APP-TA SBS-TA or APP- TA -45.0* SC-86 Min. 22 ga., Type B, Grade 33 steel 0.5-inch DensDeck Prime or SECUROCK Gypsum Fiber Roof Board Note 2 (Drill-Tec 3 in. Ribbed Galvalume Plate (Flat) may be used) 1 per 4.0 ft2 GAF SA Vapor Retarder XL, self-adhering One or more layers, base layer min. 1-inch thick, optional subsequent layer(s) min. 1.5- inch thick EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-M, LRF- XF or OB500 SBS-TA or APP-TA (Optional) SBS-TA or APP-TA SBS-TA or APP- TA -45.0* SC-87 Min. 22 ga., Type B, Grade 33 steel 0.5-inch DensDeck Prime or SECUROCK Gypsum Fiber Roof Board Note 2 (Drill-Tec 3 in. Ribbed Galvalume Plate (Flat) may be used) 1 per 4.0 ft2 Primer: GAF SA Primer or Matrix 307 Premium Asphalt Primer Vapor Retarder: GAF SA Vapor Retarder, self-adhering One or more layers, base layer min. 1-inch thick, optional subsequent layer(s) min. 1.5- inch thick EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-M, LRF- XF or OB500 BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-AA -45.0* SC-88 Min. 22 ga., Type B, Grade 33 steel 0.5-inch DensDeck Prime or SECUROCK Gypsum Fiber Roof Board Note 2 (Drill-Tec 3 in. Ribbed Galvalume Plate (Flat) may be used) 1 per 4.0 ft2 GAF SA Vapor Retarder XL, self-adhering One or more layers, base layer min. 1-inch thick, optional subsequent layer(s) min. 1.5- inch thick EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-M, LRF- XF or OB500 BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-AA -45.0* SC-89 Min. 22 ga., Type B, Grade 33 steel 0.5-inch DensDeck Prime or SECUROCK Gypsum Fiber Roof Board Note 2 (Drill-Tec 3 in. Ribbed Galvalume Plate (Flat) may be used) 1 per 2.0 ft2 Primer: GAF SA Primer Vapor Retarder: GAF SA Vapor Retarder, self-adhering One or more layers, base layer min. 1-inch thick, optional subsequent layer(s) min. 1.5- inch thick EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-M, LRF- XF or OB500 SBS-TA or APP-TA (Optional) SBS-TA or APP-TA SBS-TA or APP- TA -67.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R35 for FL5680-R35 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 35: 04/11/2022 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 31 of 96 TABLE 2B: STEEL DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) SYSTEM TYPE B-2: MECHANICALLY ATTACHED THERMAL BARRIER, BONDED TEMP ROOF, BONDED TOP INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Thermal Barrier Temp Roof Insulation Layer(s) Roof Cover (Note 15) MDP (psf) Type Fastener (Note 11) Attach Type Attach (Notes 6,7,8) Base Ply Cap SC-90 Min. 22 ga., Type B, Grade 33 steel 0.5-inch DensDeck Prime or SECUROCK Gypsum Fiber Roof Board Note 2 (Drill-Tec 3 in. Ribbed Galvalume Plate (Flat) may be used) 1 per 2.0 ft2 Primer: GAF SA Primer Vapor Retarder: GAF SA Vapor Retarder, self-adhering One or more layers, base layer min. 1-inch thick, optional subsequent layer(s) min. 1.5- inch thick EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-M, LRF- XF or OB500 BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-AA -67.5 SELF-ADHERING BASE PLY: SC-91 Min. 22 ga., Type B, Grade 33 steel Min. 0.5-inch SECUROCK Gypsum Fiber Roof Board Note 2 (Drill-Tec 3 in. Ribbed Galvalume Plate (Flat) may be used) 1 per 2.7 ft2 Liberty SBS Self-Adhering Cap Sheet Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN followed by min. 0.25-inch SECUROCK Ultralight Coated Glass-Mat Roof Board OB500 SBS-SA None SBS-SA -37.5* SC-92 Min. 22 ga., Type B, Grade 33 steel Min. 0.5-inch SECUROCK Gypsum Fiber Roof Board Note 2 (Drill-Tec 3 in. Ribbed Galvalume Plate (Flat) may be used) 1 per 2.7 ft2 Liberty SBS Self-Adhering Cap Sheet Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN followed by min. 0.25-inch SECUROCK Ultralight Coated Glass-Mat Roof Board OB500 SBS-SA (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -37.5* SC-93 Min. 22 ga., Type B, Grade 33 steel 0.5-inch DensDeck Prime or SECUROCK Gypsum Fiber Roof Board Note 2 (Drill-Tec 3 in. Ribbed Galvalume Plate (Flat) may be used) 1 per 4.0 ft2 Primer: GAF SA Primer or Matrix 307 Premium Asphalt Primer Vapor Retarder: GAF SA Vapor Retarder, self-adhering One or more layers, base layer min. 1-inch thick, optional subsequent layer(s) min. 1.5- inch thick EnergyGuard RN Min. 0.25-inch SECUROCK Ultralight Coated Glass-Mat Roof Board LRF-M or OB500 SBS-SA (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -37.5* SC-94 Min. 22 ga., Type B, Grade 33 steel 0.5-inch DensDeck Prime or SECUROCK Gypsum Fiber Roof Board Note 2 (Drill-Tec 3 in. Ribbed Galvalume Plate (Flat) may be used) 1 per 4.0 ft2 GAF SA Vapor Retarder XL, self-adhering One or more layers, base layer min. 1-inch thick, optional subsequent layer(s) min. 1.5- inch thick EnergyGuard RN Min. 0.25-inch SECUROCK Ultralight Coated Glass-Mat Roof Board LRF-M or OB500 SBS-SA (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -37.5* SC-95 Min. 22 ga., Type B, Grade 33 steel 0.5-inch DensDeck Prime or SECUROCK Gypsum Fiber Roof Board Note 2 (Drill-Tec 3 in. Ribbed Galvalume Plate (Flat) may be used) 1 per 4.0 ft2 Primer: GAF SA Primer or Matrix 307 Premium Asphalt Primer Vapor Retarder: GAF SA Vapor Retarder, self-adhering One or more layers, base layer min. 1-inch thick, optional subsequent layer(s) min. 1.5- inch thick EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation Min. 0.25-inch SECUROCK Ultralight Coated Glass-Mat Roof Board LRF-M or OB500 SBS-SA (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -37.5* SC-96 Min. 22 ga., Type B, Grade 33 steel 0.5-inch DensDeck Prime or SECUROCK Gypsum Fiber Roof Board Note 2 (Drill-Tec 3 in. Ribbed Galvalume Plate (Flat) may be used) 1 per 4.0 ft2 GAF SA Vapor Retarder XL, self-adhering One or more layers, base layer min. 1-inch thick, optional subsequent layer(s) min. 1.5- inch thick EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation Min. 0.25-inch SECUROCK Ultralight Coated Glass-Mat Roof Board LRF-M or OB500 SBS-SA (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -37.5* NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R35 for FL5680-R35 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 35: 04/11/2022 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 32 of 96 TABLE 2B: STEEL DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) SYSTEM TYPE B-2: MECHANICALLY ATTACHED THERMAL BARRIER, BONDED TEMP ROOF, BONDED TOP INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Thermal Barrier Temp Roof Insulation Layer(s) Roof Cover (Note 15) MDP (psf) Type Fastener (Note 11) Attach Type Attach (Notes 6,7,8) Base Ply Cap SC-97 Min. 22 ga., Type B, Grade 33 steel Min. 0.5-inch SECUROCK Gypsum Fiber Roof Board Note 2 (Drill-Tec 3 in. Ribbed Galvalume Plate (Flat) may be used) 1 per 2.7 ft2 Liberty SBS Self-Adhering Cap Sheet Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 SBS-SA None SBS-SA -45.0* SC-98 Min. 22 ga., Type B, Grade 33 steel Min. 0.5-inch SECUROCK Gypsum Fiber Roof Board Note 2 (Drill-Tec 3 in. Ribbed Galvalume Plate (Flat) may be used) 1 per 2.7 ft2 Liberty SBS Self-Adhering Cap Sheet Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 SBS-SA (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -45.0* SC-99 Min. 22 ga., Type B, Grade 33 steel Min. 0.5-inch SECUROCK Gypsum Fiber Roof Board Note 2 (Drill-Tec 3 in. Ribbed Galvalume Plate (Flat) may be used) 1 per 2.7 ft2 Liberty SBS Self-Adhering Cap Sheet Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN followed by min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 SBS-SA None SBS-SA -45.0* SC-100 Min. 22 ga., Type B, Grade 33 steel Min. 0.5-inch SECUROCK Gypsum Fiber Roof Board Note 2 (Drill-Tec 3 in. Ribbed Galvalume Plate (Flat) may be used) 1 per 2.7 ft2 Liberty SBS Self-Adhering Cap Sheet Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN followed by min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 SBS-SA (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -45.0* SC-101 Min. 22 ga., Type B, Grade 33 steel Min. 0.5-inch SECUROCK Gypsum Fiber Roof Board Note 2 (Drill-Tec 3 in. Ribbed Galvalume Plate (Flat) may be used) 1 per 2.7 ft2 Liberty SBS Self-Adhering Cap Sheet Min. 1.5-inch EnergyGuard RH followed by Min. 0.5-inch EnergyGuard RH HD Polyiso Insulation, EnergyGuard HD Polyiso Cover Board, EnergyGuard HD Plus Polyiso Cover Board OB500 SBS-SA (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -45.0* SC-102 Min. 22 ga., Type B, Grade 33 steel 0.5-inch DensDeck Prime or SECUROCK Gypsum Fiber Roof Board Note 2 (Drill-Tec 3 in. Ribbed Galvalume Plate (Flat) may be used) 1 per 4.0 ft2 Primer: GAF SA Primer or Matrix 307 Premium Asphalt Primer Vapor Retarder: GAF SA Vapor Retarder, self-adhering One or more layers, base layer min. 1-inch thick, optional subsequent layer(s) min. 1.5- inch thick EnergyGuard RN (Optional) Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board or min. 0.5-inch EnergyGuard HD Polyiso Cover Board or EnergyGuard HD Plus Polyiso Cover Board LRF-M or OB500 SBS-SA (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -45.0* SC-103 Min. 22 ga., Type B, Grade 33 steel 0.5-inch DensDeck Prime or SECUROCK Gypsum Fiber Roof Board Note 2 (Drill-Tec 3 in. Ribbed Galvalume Plate (Flat) may be used) 1 per 4.0 ft2 GAF SA Vapor Retarder XL, self-adhering One or more layers, base layer min. 1-inch thick, optional subsequent layer(s) min. 1.5- inch thick EnergyGuard RN (Optional) Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board or min. 0.5-inch EnergyGuard HD Polyiso Cover Board or EnergyGuard HD Plus Polyiso Cover Board LRF-M or OB500 SBS-SA (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -45.0* NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R35 for FL5680-R35 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 35: 04/11/2022 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 33 of 96 TABLE 2B: STEEL DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) SYSTEM TYPE B-2: MECHANICALLY ATTACHED THERMAL BARRIER, BONDED TEMP ROOF, BONDED TOP INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Thermal Barrier Temp Roof Insulation Layer(s) Roof Cover (Note 15) MDP (psf) Type Fastener (Note 11) Attach Type Attach (Notes 6,7,8) Base Ply Cap SC-104 Min. 22 ga., Type B, Grade 33 steel 0.5-inch DensDeck Prime or SECUROCK Gypsum Fiber Roof Board Note 2 (Drill-Tec 3 in. Ribbed Galvalume Plate (Flat) may be used) 1 per 4.0 ft2 Primer: GAF SA Primer or Matrix 307 Premium Asphalt Primer Vapor Retarder: GAF SA Vapor Retarder, self-adhering One or more layers, base layer min. 1-inch thick, optional subsequent layer(s) min. 1.5- inch thick EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation (Optional) Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board or min. 0.5-inch EnergyGuard HD Polyiso Cover Board or EnergyGuard HD Plus Polyiso Cover Board LRF-M, LRF- XF or OB500 SBS-SA (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -45.0* SC-105 Min. 22 ga., Type B, Grade 33 steel 0.5-inch DensDeck Prime or SECUROCK Gypsum Fiber Roof Board Note 2 (Drill-Tec 3 in. Ribbed Galvalume Plate (Flat) may be used) 1 per 4.0 ft2 GAF SA Vapor Retarder XL, self-adhering One or more layers, base layer min. 1-inch thick, optional subsequent layer(s) min. 1.5- inch thick EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation (Optional) Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board or min. 0.5-inch EnergyGuard HD Polyiso Cover Board or EnergyGuard HD Plus Polyiso Cover Board LRF-M, LRF- XF or OB500 SBS-SA (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -45.0* SC-106 Min. 22 ga., Type B, Grade 33 steel 0.5-inch DensDeck Prime or SECUROCK Gypsum Fiber Roof Board Note 2 (Drill-Tec 3 in. Ribbed Galvalume Plate (Flat) may be used) 1 per 2.0 ft2 Primer: GAF SA Primer Vapor Retarder: GAF SA Vapor Retarder, self-adhering One or more layers, base layer min. 1-inch thick, optional subsequent layer(s) min. 1.5- inch thick EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation (Optional) Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board or min. 0.5-inch EnergyGuard HD Polyiso Cover Board or EnergyGuard HD Plus Polyiso Cover Board LRF-M, LRF- XF or OB500 SBS-SA (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -67.5 VENTING SYSTEMS: SC-107 Min. 22 ga., Type B, Grade 33 steel 0.5-inch DensDeck Prime or SECUROCK Gypsum Fiber Roof Board Note 2 (Drill-Tec 3 in. Ribbed Galvalume Plate (Flat) may be used) 1 per 4.0 ft2 Primer: GAF SA Primer or Matrix 307 Premium Asphalt Primer Vapor Retarder: GAF SA Vapor Retarder, self-adhering One or more layers, base layer min. 1-inch thick, optional subsequent layer(s) min. 1.5- inch thick EnergyGuard RN (Optional) Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-M or OB500 GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP- AA, SBS- AA SBS-AA -45.0* SC-108 Min. 22 ga., Type B, Grade 33 steel 0.5-inch DensDeck Prime or SECUROCK Gypsum Fiber Roof Board Note 2 (Drill-Tec 3 in. Ribbed Galvalume Plate (Flat) may be used) 1 per 4.0 ft2 GAF SA Vapor Retarder XL, self-adhering One or more layers, base layer min. 1-inch thick, optional subsequent layer(s) min. 1.5- inch thick EnergyGuard RN (Optional) Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-M or OB500 GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP- AA, SBS- AA SBS-AA -45.0* NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R35 for FL5680-R35 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 35: 04/11/2022 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 34 of 96 TABLE 2B: STEEL DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) SYSTEM TYPE B-2: MECHANICALLY ATTACHED THERMAL BARRIER, BONDED TEMP ROOF, BONDED TOP INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Thermal Barrier Temp Roof Insulation Layer(s) Roof Cover (Note 15) MDP (psf) Type Fastener (Note 11) Attach Type Attach (Notes 6,7,8) Base Ply Cap SC-109 Min. 22 ga., Type B, Grade 33 steel 0.5-inch DensDeck Prime or SECUROCK Gypsum Fiber Roof Board Note 2 (Drill-Tec 3 in. Ribbed Galvalume Plate (Flat) may be used) 1 per 4.0 ft2 Primer: GAF SA Primer or Matrix 307 Premium Asphalt Primer Vapor Retarder: GAF SA Vapor Retarder, self-adhering One or more layers, base layer min. 1-inch thick, optional subsequent layer(s) min. 1.5- inch thick EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation (Optional) Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-M, LRF- XF or OB500 GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP- AA, SBS- AA SBS-AA -45.0* SC-110 Min. 22 ga., Type B, Grade 33 steel 0.5-inch DensDeck Prime or SECUROCK Gypsum Fiber Roof Board Note 2 (Drill-Tec 3 in. Ribbed Galvalume Plate (Flat) may be used) 1 per 4.0 ft2 GAF SA Vapor Retarder XL, self-adhering One or more layers, base layer min. 1-inch thick, optional subsequent layer(s) min. 1.5- inch thick EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation (Optional) Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-M, LRF- XF or OB500 GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP- AA, SBS- AA SBS-AA -45.0* SC-111 Min. 22 ga., Type B, Grade 33 steel 0.5-inch DensDeck Prime or SECUROCK Gypsum Fiber Roof Board Note 2 (Drill-Tec 3 in. Ribbed Galvalume Plate (Flat) may be used) 1 per 2.0 ft2 Primer: GAF SA Primer Vapor Retarder: GAF SA Vapor Retarder, self-adhering One or more layers, base layer min. 1-inch thick, optional subsequent layer(s) min. 1.5- inch thick EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation (Optional) Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-M, LRF- XF or OB500 GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP- AA, SBS- AA SBS-AA -67.5 COLD-APPLIED SYSTEMS: SC-112 Min. 22 ga., Type B, Grade 33 steel Min.0.5-inch SECUROCK Gypsum Fiber Roof Board Note 2 (Drill-Tec 3 in. Ribbed Galvalume Plate (Flat) may be used) 1 per 2.7 ft2 Liberty SBS Self-Adhering Cap Sheet Min. 1.5-inch EnergyGuard RH followed by Min. 0.5-inch EnergyGuard RH HD Polyiso Insulation, EnergyGuard HD Polyiso Cover Board, EnergyGuard HD Plus Polyiso Cover Board OB500 SBS-CA or SBS-CA1 None SBS-CA or SBS- CA1 -45.0* SC-113 Min. 22 ga., Type B, Grade 33 steel 0.5-inch DensDeck Prime or SECUROCK Gypsum Fiber Roof Board Note 2 (Drill-Tec 3 in. Ribbed Galvalume Plate (Flat) may be used) 1 per 4.0 ft2 Primer: GAF SA Primer or Matrix 307 Premium Asphalt Primer Vapor Retarder: GAF SA Vapor Retarder, self-adhering One or more layers, base layer min. 1-inch thick, optional subsequent layer(s) min. 1.5- inch thick EnergyGuard RN (Optional) Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board or min. 0.5-inch EnergyGuard HD Polyiso Cover Board or EnergyGuard HD Plus Polyiso Cover Board LRF-M or OB500 SBS-CA1 None SBS-CA1 -45.0* SC-114 Min. 22 ga., Type B, Grade 33 steel 0.5-inch DensDeck Prime or SECUROCK Gypsum Fiber Roof Board Note 2 (Drill-Tec 3 in. Ribbed Galvalume Plate (Flat) may be used) 1 per 4.0 ft2 GAF SA Vapor Retarder XL, self-adhering One or more layers, base layer min. 1-inch thick, optional subsequent layer(s) min. 1.5- inch thick EnergyGuard RN (Optional) Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board or min. 0.5-inch EnergyGuard HD Polyiso Cover Board or EnergyGuard HD Plus Polyiso Cover Board LRF-M or OB500 SBS-CA1 None SBS-CA1 -45.0* NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R35 for FL5680-R35 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 35: 04/11/2022 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 35 of 96 TABLE 2B: STEEL DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) SYSTEM TYPE B-2: MECHANICALLY ATTACHED THERMAL BARRIER, BONDED TEMP ROOF, BONDED TOP INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Thermal Barrier Temp Roof Insulation Layer(s) Roof Cover (Note 15) MDP (psf) Type Fastener (Note 11) Attach Type Attach (Notes 6,7,8) Base Ply Cap SC-115 Min. 22 ga., Type B, Grade 33 steel 0.5-inch DensDeck Prime or SECUROCK Gypsum Fiber Roof Board Note 2 (Drill-Tec 3 in. Ribbed Galvalume Plate (Flat) may be used) 1 per 4.0 ft2 Primer: GAF SA Primer or Matrix 307 Premium Asphalt Primer Vapor Retarder: GAF SA Vapor Retarder, self-adhering One or more layers, base layer min. 1-inch thick, optional subsequent layer(s) min. 1.5- inch thick EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation (Optional) Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board or min. 0.5-inch EnergyGuard HD Polyiso Cover Board or EnergyGuard HD Plus Polyiso Cover Board LRF-M, LRF- XF or OB500 SBS-CA1 None SBS-CA1 -45.0* SC-116 Min. 22 ga., Type B, Grade 33 steel 0.5-inch DensDeck Prime or SECUROCK Gypsum Fiber Roof Board Note 2 (Drill-Tec 3 in. Ribbed Galvalume Plate (Flat) may be used) 1 per 4.0 ft2 GAF SA Vapor Retarder XL, self-adhering One or more layers, base layer min. 1-inch thick, optional subsequent layer(s) min. 1.5- inch thick EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation (Optional) Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board or min. 0.5-inch EnergyGuard HD Polyiso Cover Board or EnergyGuard HD Plus Polyiso Cover Board LRF-M, LRF- XF or OB500 SBS-CA1 None SBS-CA1 -45.0* SC-117 Min. 22 ga., Type B, Grade 33 steel 0.5-inch DensDeck Prime or SECUROCK Gypsum Fiber Roof Board Note 2 (Drill-Tec 3 in. Ribbed Galvalume Plate (Flat) may be used) 1 per 2.0 ft2 Primer: GAF SA Primer Vapor Retarder: GAF SA Vapor Retarder, self-adhering One or more layers, base layer min. 1-inch thick, optional subsequent layer(s) min. 1.5- inch thick EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation (Optional) Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board or min. 0.5-inch EnergyGuard HD Polyiso Cover Board or EnergyGuard HD Plus Polyiso Cover Board LRF-M, LRF- XF or OB500 SBS-CA1 None SBS-CA1 -67.5 HYBRID HOT/COLD APPLIED SYSTEMS: SC-118 Min. 22 ga., Type B, Grade 33 steel 0.5-inch DensDeck Prime or SECUROCK Gypsum Fiber Roof Board Note 2 (Drill-Tec 3 in. Ribbed Galvalume Plate (Flat) may be used) 1 per 4.0 ft2 Primer: GAF SA Primer or Matrix 307 Premium Asphalt Primer Vapor Retarder: GAF SA Vapor Retarder, self-adhering One or more layers, base layer min. 1-inch thick, optional subsequent layer(s) min. 1.5- inch thick EnergyGuard RN Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-M or OB500 BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -45.0* SC-119 Min. 22 ga., Type B, Grade 33 steel 0.5-inch DensDeck Prime or SECUROCK Gypsum Fiber Roof Board Note 2 (Drill-Tec 3 in. Ribbed Galvalume Plate (Flat) may be used) 1 per 4.0 ft2 GAF SA Vapor Retarder XL, self-adhering One or more layers, base layer min. 1-inch thick, optional subsequent layer(s) min. 1.5- inch thick EnergyGuard RN Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-M or OB500 BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -45.0* NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R35 for FL5680-R35 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 35: 04/11/2022 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 36 of 96 TABLE 2B: STEEL DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) SYSTEM TYPE B-2: MECHANICALLY ATTACHED THERMAL BARRIER, BONDED TEMP ROOF, BONDED TOP INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Thermal Barrier Temp Roof Insulation Layer(s) Roof Cover (Note 15) MDP (psf) Type Fastener (Note 11) Attach Type Attach (Notes 6,7,8) Base Ply Cap SC-120 Min. 22 ga., Type B, Grade 33 steel 0.5-inch DensDeck Prime or SECUROCK Gypsum Fiber Roof Board Note 2 (Drill-Tec 3 in. Ribbed Galvalume Plate (Flat) may be used) 1 per 4.0 ft2 Primer: GAF SA Primer or Matrix 307 Premium Asphalt Primer Vapor Retarder: GAF SA Vapor Retarder, self-adhering One or more layers, base layer min. 1-inch thick, optional subsequent layer(s) min. 1.5- inch thick EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-M, LRF- XF or OB500 BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -45.0* SC-121 Min. 22 ga., Type B, Grade 33 steel 0.5-inch DensDeck Prime or SECUROCK Gypsum Fiber Roof Board Note 2 (Drill-Tec 3 in. Ribbed Galvalume Plate (Flat) may be used) 1 per 4.0 ft2 GAF SA Vapor Retarder XL, self-adhering One or more layers, base layer min. 1-inch thick, optional subsequent layer(s) min. 1.5- inch thick EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-M, LRF- XF or OB500 BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -45.0* SC-122 Min. 22 ga., Type B, Grade 33 steel 0.5-inch DensDeck Prime or SECUROCK Gypsum Fiber Roof Board Note 2 (Drill-Tec 3 in. Ribbed Galvalume Plate (Flat) may be used) 1 per 2.0 ft2 Primer: GAF SA Primer Vapor Retarder: GAF SA Vapor Retarder, self-adhering One or more layers, base layer min. 1-inch thick, optional subsequent layer(s) min. 1.5- inch thick EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-M, LRF- XF or OB500 BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -67.5 TABLE 2C: STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer (Note 13) Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Fasteners (Note 11) Attach Base Ply Ply Cap Ply CONVENTIONAL SYSTEMS: SC-123 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Note 2 1 per 4.0 ft2 SBS-TA or APP-TA (Optional) SBS-TA or APP-TA SBS-TA or APP-TA -30.0* SC-124 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete (Optional) One or more layers, any combination, loose laid Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Note 2 1 per 3.2 ft2 SBS-TA or APP-TA (Optional) SBS-TA or APP-TA SBS-TA or APP-TA -37.5* SC-125 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.625-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Note 2 1 per 4.0 ft2 SBS-TA or APP-TA (Optional) SBS-TA or APP-TA SBS-TA or APP-TA -45.0* SC-126 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Note 2 1 per 2.13 ft2 SBS-TA or APP-TA (Optional) SBS-TA or APP-TA SBS-TA or APP-TA -45.0* NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R35 for FL5680-R35 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 35: 04/11/2022 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 37 of 96 TABLE 2C: STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer (Note 13) Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Fasteners (Note 11) Attach Base Ply Ply Cap Ply SC-127 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.5-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Note 2 1 per 3.2 ft2 SBS-TA or APP-TA (Optional) SBS-TA or APP-TA SBS-TA or APP-TA -45.0* SC-128 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.25-inch DensDeck, DensDeck Prime Note 2 1 per 4.0 ft2 BP-AA, SBS-AA (Optional) BP- AA, SBS-AA SBS-AA, SBS-TA, APP-TA -45.0* SC-129 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation or Structodek High Density Fiberboard Roof Insulation Note 2 1 per 2.0 ft2 SBS-AA (Optional) SBS-AA SBS-AA, SBS-TA -45.0* SC-130 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Note 2 1 per 2.0 ft2 BP-AA, SBS-AA, SBS- TA or APP-TA (Optional) BP- AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -45.0* SC-131 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Note 2 1 per 4.0 ft2 BP-AA or SBS-AA (Optional) BP- AA, SBS-AA, SBS-TA SBS-AA, SBS-TA -45.0* SC-132 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Note 2 1 per 1.6 ft2 SBS-AA, SBS-TA, APP- TA (Optional) SBS-AA, SBS- TA, APP-TA SBS-AA, SBS-TA, APP-TA -52.5 SC-133 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.25-inch DensDeck Prime Note 2 1 per 1.45 ft2 SBS-AA, SBS-TA, APP- TA (Optional) SBS-AA, SBS- TA, APP-TA SBS-AA, SBS-TA, APP-TA -52.5 SC-134 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.5-inch SECUROCK Gypsum-Fiber Roof Board Note 2 1 per 1.8 ft2 SBS-TA, APP-TA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -52.5 SC-135 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.5-inch SECUROCK Gypsum-Fiber Roof Board Note 2 (#14 only) 1 per 1.8 ft2 BP-AA, SBS-AA (Optional) BP- AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -60.0 SC-136 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Note 2 1 per 1.3 ft2 SBS-TA, APP-TA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -60.0 SC-137 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.5-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Note 2 1 per 2.0 ft2 BP-AA or SBS-AA (Optional) BP- AA, SBS-AA, SBS-TA SBS-AA, SBS-TA -60.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R35 for FL5680-R35 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 35: 04/11/2022 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 38 of 96 TABLE 2C: STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer (Note 13) Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Fasteners (Note 11) Attach Base Ply Ply Cap Ply SC-138 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation Note 2 1 per 1.0 ft2 SBS-AA (Optional) SBS-AA or SBS-TA SBS-AA, SBS-TA -67.5 SC-139 Min. 22 ga., type B, Grade 40 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.25-inch DensDeck Prime Note 2 1 per 1.45 ft2 SBS-TA (Optional) SBS-TA SBS-TA -67.5 SC-140 Min. 22 ga., Type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.375-inch SECUROCK Gypsum-Fiber Roof Board Note 2 1 per 1.3 ft2 SBS-TA, APP-TA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -67.5 SC-141 Min. 22 ga., type B, Grade 40 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Note 2 1 per 1.45 ft2 SBS-TA (Optional) SBS-TA SBS-TA -75.0 SC-142 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.5-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Note 2 1 per 1.6 ft2 BP-AA or SBS-AA (Optional) BP- AA, SBS-AA, SBS-TA SBS-AA, SBS-TA -82.5 SC-143 Min. 20 ga., type B, Grade 33 steel, min. 22 ga., type B, Grade 80 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.5-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Note 2 1 per 1.6 ft2 BP-AA or SBS-AA (Optional) BP- AA, SBS-AA, SBS-TA SBS-AA, SBS-TA -90.0 SC-144 Min. 20 ga., type B, Grade 33 steel or min. 22 ga., type B, Grade 80 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.5-inch DensDeck Prime Note 2 1 per 1.0 ft2 SBS-TA, APP-TA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -90.0 SC-145 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.5-inch SECUROCK Gypsum-Fiber Roof Board Note 2 1 per 1.0 ft2 SBS-TA, APP-TA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -97.5 SC-146 Min. 20 ga., type B, Grade 33 steel, min. 22 ga., type B, Grade 80 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.5-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Note 2 1 per 1.45 ft2 BP-AA or SBS-AA (Optional) BP- AA, SBS-AA, SBS-TA SBS-AA, SBS-TA -97.5 SC-147 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.5-inch DensDeck Prime Note 2 (#14 only) 1 per 1.0 ft2 SBS-TA, APP-TA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -105.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R35 for FL5680-R35 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 35: 04/11/2022 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 39 of 96 TABLE 2C: STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer (Note 13) Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Fasteners (Note 11) Attach Base Ply Ply Cap Ply SC-148 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.5-inch SECUROCK Gypsum-Fiber Roof Board Note 2 (#14 only) 1 per 1.0 ft2 APP-TA (Optional) APP-TA APP-TA -105.0 SC-149 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Optional BP-AA or SBS-AA vapor barrier over concrete deck. One or more layers, any combination, loose laid Min. 0.5-inch SECUROCK Gypsum-Fiber Roof Board Note 2 (#14 only) 1 per 1.0 ft2 SBS-TA (Optional) SBS-TA SBS-TA -120.0 SC-150 Min. 22 ga., type B, Grade 80 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.5-inch DensDeck Prime Note 2 1 per 1.0 ft2 SBS-TA (Optional) SBS-TA SBS-TA -127.5 SELF-ADHERING BASE PLY: SC-151 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Note 2 1 per 3.2 ft2 SBS-SA (Optional) SBS-SA, SBS- TA, APP-TA SBS-SA, SBS-TA, APP-TA -30.0* SC-152 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete (Optional) One or more layers, any combination, loose laid Min. 2.0-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra Note 2 1 per 4.0 ft2 SBS-SA (Optional) SBS-SA, SBS- TA, APP-TA SBS-SA, SBS-TA, APP-TA -37.5* SC-153 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete (Optional) One or more layers, any combination, loose laid Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Note 2 1 per 4.0 ft2 SBS-SA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -37.5* SC-154 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.375-inch SECUROCK Gypsum-Fiber Roof Board or SECUROCK Ultralight Coated Glass-Mat Roof Board Note 2 1 per 2.7 ft2 SBS-SA (Optional) SBS-SA, SBS- TA, APP-TA SBS-SA, SBS-TA, APP-TA -45.0* SC-155 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Note 2 1 per 2.0 ft2 SBS-SA (Optional) SBS-TA or APP-TA SBS-TA or APP-TA -45.0* SC-156 Min. 22 ga., Type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.5-inch EnergyGuard RH HD Polyiso Insulation, EnergyGuard HD Polyiso Cover Board, EnergyGuard HD Plus Polyiso Cover Board Note 2 1 per 2.0 ft2 SBS-SA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -45.0* SC-157 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete (Optional) One or more layers, any combination, loose laid Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra Note 2 1 per 2.0 ft2 SBS-SA (Optional) SBS-SA SBS-SA -45.0* SC-158 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete (Optional) One or more layers, any combination, loose laid Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Note 2 1 per 2.0 ft2 SBS-SA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -45.0* NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R35 for FL5680-R35 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 35: 04/11/2022 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 40 of 96 TABLE 2C: STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer (Note 13) Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Fasteners (Note 11) Attach Base Ply Ply Cap Ply SC-159 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete (Optional) One or more layers, any combination, loose laid Min. 2.0-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Note 2 1 per 3.2 ft2 SBS-SA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -45.0* SC-160 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete (Optional) One or more layers, any combination, loose laid Min. 2.0-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra Note 2 1 per 2.0 ft2 SBS-SA (Optional) SBS-SA SBS-SA -45.0* SC-161 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Note 2 1 per 1.6 ft2 SBS-SA (Optional) SBS-TA or APP-TA SBS-TA or APP-TA -52.5 SC-162 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.5-inch SECUROCK Gypsum-Fiber Roof Board Note 2 1 per 1.8 ft2 SBS-SA (Optional) SBS-TA or APP-TA SBS-TA or APP-TA -52.5 SC-163 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.25-inch SECUROCK Ultralight Coated Glass- Mat Roof Board Note 2 1 per 1.3 ft2 SBS-SA (Optional) SBS-TA or APP-TA SBS-TA or APP-TA -52.5 SC-164 Min. 22 ga., type B, Grade 50 steel or min. 2,500 psi structural concrete (Optional) One or more layers, any combination, loose laid Min. 1.5-inch EnergyGuard Polyiso Insulation Note 2 1 per 1.8 ft2 SBS-SA (Optional) SBS-TA SBS-TA -60.0 SC-165 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete (Optional) One or more layers, any combination, loose laid Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra Note 2 1 per 1.3 ft2 SBS-SA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -60.0 SC-166 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete (Optional) One or more layers, any combination, loose laid Min. 2.0-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra Note 2 1 per 1.45 ft2 SBS-SA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -60.0 SC-167 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete (Optional) One or more layers, any combination, loose laid Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Note 2 1 per 1.8 ft2 SBS-SA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -60.0 SC-168 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Note 2 1 per 1.3 ft2 SBS-SA (Optional) SBS-TA or APP-TA SBS-TA or APP-TA -60.0 SC-169 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.5-inch SECUROCK Gypsum-Fiber Roof Board Note 2 (#14 only) 1 per 1.8 ft2 SBS-SA (Optional) SBS-TA or APP-TA SBS-TA or APP-TA -60.0 SC-170 Min. 22 ga., Type B, Grade 33 steel or min. 2,500 psi structural concrete (Optional) One or more layers, any combination, loose laid Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Note 2 1 per 1.3 ft2 SBS-SA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -67.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R35 for FL5680-R35 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 35: 04/11/2022 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 41 of 96 TABLE 2C: STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer (Note 13) Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Fasteners (Note 11) Attach Base Ply Ply Cap Ply SC-171 Min. 22 ga., Type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.375-inch SECUROCK Gypsum-Fiber Roof Board Note 2 1 per 1.3 ft2 SBS-SA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -67.5 VENTING SYSTEMS: SC-172 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete (Optional) One or more layers, any combination, loose laid Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Note 2 1 per 4.0 ft2 GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS-AA SBS-AA -37.5* SC-173 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete (Optional) One or more layers, any combination, loose laid Min. 1.5-inch EnergyGuard Polyiso Insulation Note 2 1 per 2.0 ft2 GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS-AA SBS-AA -45.0* SC-174 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete (Optional) One or more layers, any combination, loose laid Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Note 2 1 per 2.0 ft2 GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS-AA SBS-AA -45.0* SC-175 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete (Optional) One or more layers, any combination, loose laid Min. 2.0-inch EnergyGuard RH Note 2 1 per 2.9 ft2 GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS-AA SBS-AA -45.0* SC-176 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete (Optional) One or more layers, any combination, loose laid Min. 1.5-inch EnergyGuard Ultra Note 2 1 per 3.2 ft2 GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS-AA SBS-AA -45.0* SC-177 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete (Optional) One or more layers, any combination, loose laid Min. 2.5-inch EnergyGuard RA Note 2 1 per 4.0 ft2 GAFGLAS Stratavent Perforated Venting Base Sheet BP-AA, SBS-AA SBS-AA -45.0* SC-178 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete (Optional) One or more layers, any combination, loose laid Min. 3-inch EnergyGuard RH, EnergyGuard RN Note 2 1 per 3.2 ft2 GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS-AA SBS-AA -45.0* SC-179 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete (Optional) One or more layers, any combination, loose laid Min. 3-inch EnergyGuard Polyiso Insulation Note 2 1 per 3.2 ft2 GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS-AA SBS-AA -45.0* SC-180 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete (Optional) One or more layers, any combination, loose laid Min. 3-inch EnergyGuard Polyiso Insulation Note 2 1 per 4.0 ft2 GAFGLAS Stratavent Perforated Venting Base Sheet One or more BP-AA, SBS-AA SBS-AA -45.0* SC-181 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete (Optional) One or more layers, any combination, loose laid Min. 1.5-inch EnergyGuard Polyiso Insulation Note 2 1 per 2.0 ft2 GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS-AA SBS-AA -52.5 SC-182 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete (Optional) One or more layers, any combination, loose laid Min. 2-inch EnergyGuard RH Note 2 1 per 2.0 ft2 GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS-AA SBS-AA -52.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R35 for FL5680-R35 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 35: 04/11/2022 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 42 of 96 TABLE 2C: STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer (Note 13) Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Fasteners (Note 11) Attach Base Ply Ply Cap Ply SC-183 Min. 22 ga., type B, Grade 50 steel or min. 2,500 psi structural concrete (Optional) One or more layers, any combination, loose laid Min. 1.5-inch EnergyGuard Polyiso Insulation Note 2 1 per 1.8 ft2 GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS-AA SBS-AA -60.0 SC-184 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete (Optional) One or more layers, any combination, loose laid Min. 2.0-inch EnergyGuard Ultra Note 2 1 per 2.0 ft2 GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS-AA SBS-AA -60.0 SC-185 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete (Optional) One or more layers, any combination, loose laid Min. 2-inch EnergyGuard Polyiso Insulation Note 2 1 per 2.0 ft2 GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS-AA SBS-AA -60.0 SC-186 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete (Optional) One or more layers, any combination, loose laid Min. 2-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Note 2 1 per 1.45 ft2 GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS-AA SBS-AA -67.5 SC-187 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete (Optional) One or more layers, any combination, loose laid Min. 3-inch EnergyGuard RH, EnergyGuard RN Note 2 1 per 1.6 ft2 GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS-AA SBS-AA -67.5 SC-188 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete (Optional) One or more layers, any combination, loose laid Min. 2-inch EnergyGuard Polyiso Insulation Note 2 1 per 1.45 ft2 GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS-AA SBS-AA -75.0 SC-189 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete (Optional) One or more layers, any combination, loose laid Min. 2.0-inch EnergyGuard Ultra Note 2 1 per 1.45 ft2 GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS-AA SBS-AA -75.0 SC-190 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete (Optional) One or more layers, any combination, loose laid Min. 2-inch EnergyGuard Polyiso Insulation or EnergyGuard RH Note 2 1 per 1.45 ft2 GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS-AA SBS-AA (ASTM D6164, polyester only) -82.5 SC-191 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete (Optional) One or more layers, any combination, loose laid Min. 3-inch EnergyGuard Polyiso Insulation Note 2 1 per 1.6 ft2 GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS-AA SBS-AA -82.5 SC-192 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.25-inch DensDeck Note 2 1 per 1.0 ft2 GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS-AA SBS-AA -82.5 SC-193 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Note 2 1 per 1.0 ft2 GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS-AA SBS-AA -97.5 COLD-APPLIED SYSTEMS: NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R35 for FL5680-R35 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 35: 04/11/2022 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 43 of 96 TABLE 2C: STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer (Note 13) Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Fasteners (Note 11) Attach Base Ply Ply Cap Ply SC-194 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation Note 2 1 per 2.0 ft2 BP-CA None SBS-CA -45.0* SC-195 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Note 2 1 per 4.0 ft2 SBS-CA None SBS-CA -45.0* SC-196 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete (Optional) One or more layers, any combination, loose laid Min. 1.5-inch EnergyGuard RH, EnergyGuard RN, EnergyGuard Polyiso Insulation Note 2 1 per 2.0 ft2 SBS-CA1 None SBS-CA1 -45.0* SC-197 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete (Optional) One or more layers, any combination, loose laid Min. 2-inch EnergyGuard RH, EnergyGuard RN, EnergyGuard Polyiso Insulation Note 2 1 per 2.9 ft2 SBS-CA1 None SBS-CA1 -45.0* SC-198 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Note 2 1 per 2.0 ft2 SBS-CA1 None SBS-CA1 -45.0* SC-199 Min. 22 ga., Type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination, min. 1.5-inch Min. 0.5-inch EnergyGuard RH HD Polyiso Insulation, EnergyGuard HD Polyiso Cover Board, EnergyGuard HD Plus Polyiso Cover Board Note 2 1 per 2.0 ft2 SBS-CA or SBS-CA1 None SBS-CA or SBS-CA1 -45.0* SC-200 Min. 22 ga., Type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Note 2 (AccuTrac Flat Plates only) 1 per 1.3 ft2 SBS-CA1 None SBS-CA1 -52.5 SC-201 Min. 22 ga., type B, Grade 50 steel or min. 2,500 psi structural concrete (Optional) One or more layers, any combination, loose laid Min. 1.5-inch EnergyGuard Polyiso Insulation Note 2 1 per 1.8 ft2 SBS-CA1 None SBS-CA1 -60.0 SC-202 Min. 22 ga., Type B, Grade 33 steel or min. 2,500 psi structural concrete (Optional) One or more layers, any combination, loose laid Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN, EnergyGuard Polyiso Insulation, EnergyGuard Ultra Note 2 1 per 1.3 ft2 SBS-CA1 None SBS-CA1 -67.5 SC-203 Min. 22 ga., Type B, Grade 33 steel or min. 2,500 psi structural concrete (Optional) One or more layers, any combination, loose laid Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Note 2 1 per 1.8 ft2 SBS-CA1 None SBS-CA1 -67.5 SC-204 Min. 22 ga., Type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.375-inch SECUROCK Gypsum-Fiber Roof Board Note 2 1 per 1.3 ft2 SBS-CA1 None SBS-CA1 -67.5 HYBRID HOT/COLD-APPLIED SYSTEMS: NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R35 for FL5680-R35 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 35: 04/11/2022 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 44 of 96 TABLE 2C: STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer (Note 13) Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Fasteners (Note 11) Attach Base Ply Ply Cap Ply SC-205 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Note 2 1 per 4.0 ft2 BP-AA or SBS-AA (Optional) BP- AA or SBS-AA SBS-CA1 -45.0* SC-206 Min. 22 ga., Type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Note 2 (AccuTrac Flat Plates) 1 per 1.3 ft2 BP-AA or SBS-AA (Optional) BP- AA or SBS-AA SBS-CA1 -52.5 SC-207 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.5-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Note 2 1 per 2.0 ft2 BP-AA or SBS-AA (Optional) BP- AA or SBS-AA SBS-CA1 -60.0 SC-208 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.5-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Note 2 1 per 1.6 ft2 BP-AA or SBS-AA (Optional) BP- AA or SBS-AA SBS-CA1 -82.5 SC-209 Min. 20 ga., type B, Grade 33 steel, min. 22 ga., type B, Grade 80 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.5-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Note 2 1 per 1.6 ft2 BP-AA or SBS-AA (Optional) BP- AA or SBS-AA SBS-CA1 -90.0 SC-210 Min. 20 ga., type B, Grade 33 steel, min. 22 ga., type B, Grade 80 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.5-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Note 2 1 per 1.45 ft2 BP-AA or SBS-AA (Optional) BP- AA or SBS-AA SBS-CA1 -97.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R35 for FL5680-R35 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 35: 04/11/2022 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 45 of 96 TABLE 2D: STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE C-1A: THERMAL BARRIER WITH VAPOR BARRIER, MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Fasten (Note 11) Attach Base Ply Ply Cap Ply SELF-ADHERING BASE PLY: SC-211 Min. 22 ga., Type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 0.625-inch DensDeck Prime or min. 0.5-inch SECUROCK Gypsum-Fiber Roof Board, loose-laid, covered with GAF SA Vapor Retarder or GAF SA Vapor Retarder XL, self-adhered Min. 1.5-inch EnergyGuard RH, loose laid, followed by min. 0.5-inch EnergyGuard RH HD Polyiso Insulation, EnergyGuard HD Polyiso Cover Board, EnergyGuard HD Plus Polyiso Cover Board Note 2 1 per 2.0 ft2 SBS-SA (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -45.0* COLD-APPLIED BASE PLY: SC-212 Min. 22 ga., Type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 0.625-inch DensDeck Prime or min. 0.5-inch SECUROCK Gypsum-Fiber Roof Board, loose-laid, covered with GAF SA Vapor Retarder or GAF SA Vapor Retarder XL, self-adhered Min. 1.5-inch EnergyGuard RH, loose laid, followed by min. 0.5-inch EnergyGuard RH HD Polyiso Insulation, EnergyGuard HD Polyiso Cover Board, EnergyGuard HD Plus Polyiso Cover Board Note 2 1 per 2.0 ft2 SBS-CA or SBS-CA1 None SBS-CA or SBS- CA1 -45.0* TABLE 2E: STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE C-3: BONDED AND MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Adhesive & Fasteners (Notes 6,7,8,11) Attach Base Ply Ply Cap Ply CONVENTIONAL SYSTEMS: SC-213 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 2.0-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra, loose-laid Min. 0.25-inch DensDeck Prime Adhesive: OB500 Fasteners: Drill-Tec XHD (steel only) or Drill- Tec #14 HD (concrete only) & Drill-Tec Plates Adhesive: 12-inch o.c. Fasteners: 1 per 1.3 ft2 SBS-TA or APP-TA (Optional) SBS-TA or APP-TA SBS-TA or APP- TA -97.5 SC-214 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 2.0-inch EnergyGuard RA, EnergyGuard RH or EnergyGuard Ultra, loose-laid Min. 0.25-inch DensDeck Prime Adhesive: LRF-XF Fasteners: Drill-Tec XHD (steel only) or Drill- Tec #14 HD (concrete only) & Drill-Tec Plates Adhesive: 12-inch o.c. Fasteners: 1 per 1.3 ft2 SBS-TA or APP-TA (Optional) SBS-TA or APP-TA SBS-TA or APP- TA -97.5 SELF-ADHERING BASE PLY: SC-215 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 2.0-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra, loose-laid Min. 0.25-inch DensDeck Prime Adhesive: OB500 Fasteners: Drill-Tec XHD (steel only) or Drill- Tec #14 HD (concrete only) & Drill-Tec Plates Adhesive: 12-inch o.c. Fasteners: 1 per 1.3 ft2 SBS-SA (Optional) SBS-TA or APP-TA SBS-TA or APP- TA -97.5 SC-216 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 2.0-inch EnergyGuard RA, EnergyGuard RH or EnergyGuard Ultra, loose-laid Min. 0.25-inch DensDeck Prime Adhesive: LRF-XF Fasteners: Drill-Tec XHD (steel only) or Drill- Tec #14 HD (concrete only) & Drill-Tec Plates Adhesive: 12-inch o.c. Fasteners: 1 per 1.3 ft2 SBS-SA (Optional) SBS-TA or APP-TA SBS-TA or APP- TA -97.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R35 for FL5680-R35 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 35: 04/11/2022 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 46 of 96 TABLE 2F: STEEL OR STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE D-2: INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Insulation Layer(s) (Note 13) Base Sheet Roof Cover (Note 15) MDP (psf) Type Fasteners (Note 11) Attach Base Ply Cap Ply CONVENTIONAL SYSTEMS: SC-217 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete One or more layers, any combination GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet or GAFGLAS Stratavent Nailable Venting Base Sheet Note 2 24-inch o.c. at min. 2-inch laps and 24-inch o.c. in two, equally spaced, staggered center rows BP-AA, SBS- AA SBS-AA -30.0* SC-218 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete One or more layers, any combination GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet or GAFGLAS Stratavent Nailable Venting Base Sheet Note 2 18-inch o.c. at min. 2-inch laps and 18-inch o.c. in two, equally spaced, staggered center rows BP-AA, SBS- AA SBS-AA -37.5* SC-219 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete One or more layers, any combination GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet or GAFGLAS Stratavent Nailable Venting Base Sheet Note 2 18-inch o.c. at min. 2-inch laps and 18-inch o.c. in three, equally spaced, staggered center rows BP-AA, SBS- AA SBS-AA -45.0* SC-220 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete One or more layers, any combination GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet or GAFGLAS Stratavent Nailable Venting Base Sheet Note 2 12-inch o.c. at min. 2-inch laps and 18-inch o.c. in three, equally spaced, staggered center rows SBS-TA, APP- TA SBS-TA, APP-TA -45.0* SC-221 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete One or more layers, any combination GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet or GAFGLAS Stratavent Nailable Venting Base Sheet Note 2 12-inch o.c. at min. 3.5-inch laps and 12-inch o.c. in three, equally spaced, staggered center rows SBS-AA SBS-AA, SBS-TA -45.0* SC-222 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Optional BP-AA or SBS-AA vapor barrier over concrete deck. One or more layers, any combination insulation. Ruberoid Mop Smooth, Ruberoid Mop Smooth 1.5, Ruberiod Mop Plus Smooth Note 2 18-inch o.c. at min. 3.5-inch laps (Optional) SBS-TA SBS-TA -45.0* SC-223 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete One or more layers, any combination Ruberoid Mop Smooth 1.5 Note 2 18-inch o.c. at min. 3.5-inch laps BP-AA, SBS- AA SBS-AA -45.0* SC-224 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete One or more layers, any combination Ruberoid Mop Smooth 1.5 Drill-Tec 2 in. Barbed Plates with Drill-Tec #12 (steel only) or #14 Off-centered in the lap by 0.5-inch towards the sheet-edge and spaced 18-inch o.c. within the min. 4-inch wide, heat-welded laps (Optional) SBS-TA SBS-TA -45.0* NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R35 for FL5680-R35 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 35: 04/11/2022 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 47 of 96 TABLE 2F: STEEL OR STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE D-2: INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Insulation Layer(s) (Note 13) Base Sheet Roof Cover (Note 15) MDP (psf) Type Fasteners (Note 11) Attach Base Ply Cap Ply SC-225 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete One or more layers, any combination Ruberoid Mop Smooth 1.5 Drill-Tec Batten Bar with Drill- Tec #12 (steel only) or #14 18-inch o.c. within min. 4-inch wide, heat-welded laps (Optional) SBS-TA SBS-TA -45.0* SC-226 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete One or more layers, any combination Ruberoid HW Smooth Drill-Tec 2 in. Barbed Plates with Drill-Tec #12 (steel only) or #14 12-inch o.c. within min. 4-inch wide, heat-welded laps (Optional) SBS-TA SBS-TA -45.0* SC-227 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Optional BP-AA or SBS-AA vapor barrier over concrete deck. One or more layers, any combination insulation Ruberoid Mop Smooth, Ruberoid Mop Smooth 1.5, Ruberiod Mop Plus Smooth Note 2 12-inch o.c. at min. 3.5-inch laps (Optional) SBS-TA SBS-TA -52.5 SC-228 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete One or more layers, any combination Ruberoid Mop Smooth 1.5 Drill-Tec 2 in. Barbed Plates with Drill-Tec #12 (steel only) or #14 Off-centered in the lap by 0.5-inch towards the sheet-edge and spaced 12-inch o.c. within the min. 4-inch wide, heat-welded laps (Optional) SBS-TA SBS-TA -52.5 SC-229 Min. 22 ga., type B, Grade 33 steel One or more layers, any combination Ruberoid Mop Smooth 1.5 Drill-Tec 2-3/8 in. Barbed XHD Plates or Drill-Tec Eyehook AccuSeam Plates with Drill-Tec XHD Off-centered in the lap by 0.25- inch towards the sheet-edge and spaced 12-inch o.c. within the min. 5-inch wide, heat-welded laps (Optional) SBS-TA SBS-TA -67.5 SC-230 Min. 22 ga., type B, Grade 33 steel One or more layers, any combination Ruberoid Mop Smooth 1.5 Drill-Tec Batten Bar with Drill- Tec XHD 12-inch o.c. within min. 4-inch wide, heat-welded laps (Optional) SBS-TA SBS-TA -67.5 SC-231 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete One or more layers, any combination GAFGLAS #80 Ultima Base Sheet or GAFGLAS Stratavent Nailable Venting Base Sheet Note 2 6-inch o.c. at min. 3.5-inch laps and 12-inch o.c. in three, equally spaced, staggered center rows SBS-AA SBS-AA, SBS-TA -82.5 SC-232 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete One or more layers, any combination GAFGLAS #80 Ultima Base Sheet Note 2 6-inch o.c. at min. 3.5-inch laps and 12-inch o.c. in three, equally spaced, staggered center rows SBS-TA, APP- TA SBS-TA, APP-TA -82.5 SC-233 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete One or more layers, any combination GAFGLAS #75 Note 2 (Drill-Tec 3” Standard Steel Plate; Drill-Tec ASAP 3S (steel) or Drill-Tec Heavy Duty ASAP Roofing Fastener Assembled with a 3” Metal Plate only) 6-inch o.c. at min. 3.5-inch laps and 12-inch o.c. in three, equally spaced, staggered center rows SBS-TA, APP- TA SBS-TA, APP-TA -82.5 SC-234 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete One or more layers, any combination Ruberoid Mop Smooth 1.5 Note 2 18-inch o.c. at min. 3.25-inch laps and 18-inch o.c. in two, equally spaced, staggered center rows BP-AA, SBS- AA SBS-AA -105.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R35 for FL5680-R35 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 35: 04/11/2022 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 48 of 96 TABLE 2F: STEEL OR STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE D-2: INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Insulation Layer(s) (Note 13) Base Sheet Roof Cover (Note 15) MDP (psf) Type Fasteners (Note 11) Attach Base Ply Cap Ply SC-235 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Optional BP-AA or SBS-AA vapor barrier over concrete deck. One or more layers, any combination insulation Ruberoid Mop Smooth, Ruberoid Mop Smooth 1.5, Ruberiod Mop Plus Smooth Note 2 6-inch o.c. at min. 3.5-inch laps (Optional) SBS-TA SBS-TA -112.5 SC-236 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete One or more layers, any combination GAFGLAS #80 Ultima Base Sheet Note 2 6-inch o.c. at min. 3.5-inch laps and 6-inch o.c. in three, equally spaced, staggered center rows (Optional) SBS-TA SBS-TA -150.0 SC-237 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete One or more layers, any combination Ruberoid Mop Smooth 1.5 Drill-Tec #14 Fasteners with Drill-Tec 2 3/8 in. Barbed XHD Plates or Drill-Tec Eyehook AccuSeam Plates 6-inch o.c. at min. 3.25-inch laps and 6-inch o.c. in three, equally spaced, staggered center rows SBS-TA SBS-TA -150.0 SC-238 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete One or more layers, any combination GAFGLAS #75 Note 2 (Drill-Tec 3” Standard Steel Plate; Drill-Tec ASAP 3S (steel) or Drill-Tec Heavy Duty ASAP Roofing Fastener Assembled with a 3” Metal Plate only) 6-inch o.c. at min. 3.5-inch laps and 6-inch o.c. in three, equally spaced, staggered center rows (Optional) Ruberoid HW Smooth SBS-TA -150.0 SELF-ADHERING BASE PLY: SC-239 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete One or more layers, any combination Liberty SBS Mechanically Attached Base Sheet Note 2 12-inch o.c. at min. 3.5-inch laps and 18-inch o.c. in two, equally spaced, staggered center rows (Optional) SBS-SA, SBS- SA-T, SBS-TA or APP-TA SBS-SA, SBS-TA or APP-TA -30.0* SC-240 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete One or more layers, any combination Liberty SBS Mechanically Attached Base Sheet Note 2 9-inch o.c. at min. 4-inch laps and 9-inch o.c. in two, equally spaced, staggered center rows (Optional) SBS-SA SBS-SA -37.5 SC-241 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete One or more layers, any combination Liberty SBS Self-Adhering Base/Ply Sheet Note 2 12-inch o.c. at min. 3.5-inch laps and 18-inch o.c. in one center row (Optional) SBS-SA SBS-SA -45.0* COLD-APPLIED SYSTEMS: SC-242 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete One or more layers, any combination Ruberoid Mop Smooth 1.5 Note 2 18-inch o.c. at min. 3-inch laps None SBS-CA or SBS-CA1 -30.0* SC-243 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete One or more layers, any combination Ruberoid 20 Smooth Note 2 12-inch o.c. at min. 3-inch laps and 12-inch o.c. in two, equally spaced, staggered center rows None SBS-CA or SBS-CA1 -45.0* NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R35 for FL5680-R35 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 35: 04/11/2022 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 49 of 96 TABLE 2F: STEEL OR STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE D-2: INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Insulation Layer(s) (Note 13) Base Sheet Roof Cover (Note 15) MDP (psf) Type Fasteners (Note 11) Attach Base Ply Cap Ply SC-244 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete One or more layers, any combination GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet Note 2 12-inch o.c. at min. 2-inch laps and 12-inch o.c. in three, equally spaced, staggered center rows None SBS-CA -45.0* SC-245 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete One or more layers, any combination Ruberoid Mop Smooth 1.5 Note 2 24-inch o.c. at min. 3-inch laps and 24-inch o.c. in two, equally spaced, staggered center rows None SBS-CA or SBS-CA1 -45.0 SC-246 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete One or more layers, any combination GAFGLAS #80 Ultima Base Sheet or GAFGLAS Stratavent Nailable Venting Base Sheet Note 2 6-inch o.c. at min. 3.5-inch laps and 12-inch o.c. in three, equally spaced, staggered center rows SBS-CA at 2.0 gal/sq. SBS-CA at 2.0 gal/sq. -82.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R35 for FL5680-R35 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 35: 04/11/2022 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 50 of 96 TABLE 3A: STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE INSULATION LAYER ONLY) SEE NOTE 16 FOR VAPOR BARRIER OPTIONS System No. Deck (Note 1) Base Insulation Layer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply CONVENTIONAL SYSTEMS WITH BASE INSULATION LAYER ONLY C-1. Primed structural concrete Min. 0.75-inch EnergyGuard Perlite Roof Insulation (homogeneous) Hot asphalt BP-AA, SBS-AA (Optional) One or more BP- AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -140.0 C-2. Primed structural concrete Min. 0.5-inch EnergyGuard Perlite Recover Board Hot asphalt BP-AA, SBS-AA (Optional) One or more BP- AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -165.0 C-3. Primed structural concrete Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation Hot asphalt BP-AA, SBS-AA (Optional) One or more BP- AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -165.0 C-4. Primed structural concrete Min. 1.5-inch EnergyGuard Composite Hot asphalt BP-AA, SBS-AA (Optional) One or more BP- AA, SBS-AA SBS-AA, SBS-TA or APP-TA -270.0 C-5. Structural concrete Min. 0.25-inch DensDeck Prime LRF-XF SBS-TA (Optional) One or more SBS- TA SBS-TA -300.0 C-6. Structural concrete Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation OB500 BP-AA, SBS-AA (Optional) One or more BP- AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -165.0 C-7. Structural concrete Min. 0.25-inch DensDeck Prime OB500 SBS-TA (Optional) One or more SBS- TA SBS-TA -300.0 SELF-ADHERING BASE PLY WITH BASE INSULATION LAYER ONLY C-8. Primed structural concrete Min. 1.5-inch EnergyGuard Ultra Hot asphalt SBS-SA (Optional) SBS-SA, SBS-TA, APP-TA SBS-SA, SBS-TA, APP- TA -90.0 C-9. Primed structural concrete Min. 1.5-inch EnergyGuard RN Hot asphalt SBS-SA (Optional) SBS-SA, SBS-TA, APP-TA SBS-TA, APP-TA -210.0 C-10. Primed structural concrete Min. 1.5-inch EnergyGuard RA Hot asphalt SBS-SA (Optional) SBS-SA, SBS-TA, APP-TA SBS-TA, APP-TA -217.5 C-11. Structural concrete Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra LRF-M SBS-SA (Optional) SBS-TA or APP-TA SBS-TA or APP-TA -232.5 C-12. Structural concrete Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board LRF-XF SBS-SA (Optional) SBS-TA or APP-TA SBS-TA or APP-TA -137.5 C-13. Structural concrete Min. 0.5-inch EnergyGuard Polyiso Insulation LRF-XF SBS-SA (Optional) SBS-TA or APP-TA SBS-TA or APP-TA -180.0 C-14. Structural concrete Min. 0.5-inch EnergyGuard Ultra LRF-XF SBS-SA (Optional) SBS-TA or APP-TA SBS-TA or APP-TA -232.5 C-15. Structural concrete Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board primed with Matrix 307 Premium Asphalt Primer or ASTM D41 primer LRF-XF SBS-SA (Optional) SBS-TA or APP-TA SBS-TA or APP-TA -285.0 C-16. Structural concrete Min. 1.5-inch EnergyGuard RA or EnergyGuard RH LRF-XF SBS-SA (Optional) SBS-SA, SBS-TA, APP-TA SBS-TA, APP-TA -217.5 C-17. Structural concrete Min 0.5-inch Structodek High Density Fiberboard Roof Insulation OB500, 6- inch o.c. SBS-SA (Optional) SBS-SA SBS-SA -110.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R35 for FL5680-R35 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 35: 04/11/2022 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 51 of 96 TABLE 3A: STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE INSULATION LAYER ONLY) SEE NOTE 16 FOR VAPOR BARRIER OPTIONS System No. Deck (Note 1) Base Insulation Layer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply C-18. Structural concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 SBS-SA (Optional) SBS-SA SBS-SA -120.0 C-19. Structural concrete Min. 0.25-inch DensDeck OB500 SBS-SA (Optional) SBS-TA or APP-TA SBS-TA or APP-TA -122.5 C-20. Structural concrete Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 SBS-SA (Optional) SBS-TA or APP-TA SBS-TA or APP-TA -137.5 C-21. Structural concrete Min. 1-inch EnergyGuard RN OB 500 SBS-SA (Optional) SBS-TA or APP-TA SBS-TA or APP-TA -162.5 C-22. Structural concrete Min. 0.25-inch SECUROCK Ultralight Coated Glass-Mat Roof Board OB500 SBS-SA (Optional) SBS-TA or APP-TA SBS-TA or APP-TA -165.0 C-23. Structural concrete Min. 0.25-inch DensDeck primed with Matrix 307 Premium Asphalt Primer or ASTM D41 primer OB500 SBS-SA (Optional) SBS-TA or APP-TA SBS-TA or APP-TA -167.5 C-24. Structural concrete Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra OB500 SBS-SA (Optional) SBS-TA or APP-TA SBS-TA or APP-TA -232.5 C-25. Structural concrete Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board primed with Matrix 307 Premium Asphalt Primer or ASTM D41 primer OB500 SBS-SA (Optional) SBS-TA or APP-TA SBS-TA or APP-TA -285.0 VENTING SYSTEMS WITH BASE INSULATION LAYER ONLY C-26. Primed structural concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Hot asphalt GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP- AA, SBS-AA SBS-AA -150.0 C-27. Primed structural concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Hot asphalt GAFGLAS Stratavent Perforated Venting Base Sheet One or more BP-AA, SBS-AA SBS-TA or APP-TA -150.0 C-28. Primed structural concrete Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Hot asphalt GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) BP-AA, SBS-AA SBS-AA -150.0 C-29. Primed structural concrete Min. 0.5-inch EnergyGuard RN Hot asphalt GAFGLAS Stratavent Perforated Venting Base Sheet SBS-AA SBS-AA -172.5 C-30. Primed structural concrete Min. 1.5-inch EnergyGuard Ultra Hot asphalt GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP- AA, SBS-AA SBS-AA -172.5 C-31. Primed structural concrete Min. 1.5-inch EnergyGuard Ultra Hot asphalt GAFGLAS Stratavent Perforated Venting Base Sheet One or more BP-AA, SBS-AA SBS-TA or APP-TA -172.5 C-32. Primed structural concrete Min. 1-inch EnergyGuard RN Hot asphalt GAFGLAS Stratavent Perforated Venting Base Sheet One or more BP-AA, SBS-AA SBS-AA -292.5 COLD-APPLIED SYSTEMS WITH BASE INSULATION LAYER ONLY C-33. Structural concrete Min. 1.5-inch EnergyGuard RA or EnergyGuard RH LRF-XF SBS-CA1 None SBS-CA1 -60.0 C-34. Structural concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH or EnergyGuard RN OB500 SBS-CA1 None SBS-CA1 -60.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R35 for FL5680-R35 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 35: 04/11/2022 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 52 of 96 TABLE 3B: STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE AND TOP INSULATION LAYERS) SEE NOTE 16 FOR VAPOR BARRIER OPTIONS System No. Deck (Note 1) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply CONVENTIONAL SYSTEMS WITH POLYISOCYANURATE BASE INSULATION LAYER: C-35. Primed structural concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Hot asphalt Min. 0.25-inch DensDeck, DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Hot asphalt BP-AA (Optional) BP-AA SBS-AA or SBS-TA -112.5 C-36. Primed structural concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra Hot asphalt Min. 0.25-inch DensDeck Prime Hot asphalt APP-TA (Optional) APP-TA APP-TA -127.5 C-37. Primed structural concrete Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Hot asphalt Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation, EnergyGuard Perlite Recover Board, min. 0.75-inch EnergyGuard Perlite Roof Insulation, min. 0.25-inch DensDeck, DensDeck Prime, SECUROCK Gypsum Fiber Roof Board Hot asphalt BP-AA, SBS-AA (Optional) BP-AA, SBS-AA SBS-AA -150.0 C-38. Primed structural concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Hot asphalt Min. 0.75-inch EnergyGuard Perlite Roof Insulation (homogeneous) Hot asphalt BP-AA, SBS-AA (Optional) One or more BP-AA, SBS- AA, SBS-TA or APP- TA SBS-AA, SBS- TA or APP-TA -172.5 C-39. Primed structural concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Hot asphalt Min. 0.5-inch EnergyGuard Perlite Recover Board Hot asphalt BP-AA, SBS-AA (Optional) One or more BP-AA, SBS- AA, SBS-TA or APP- TA SBS-AA, SBS- TA or APP-TA -187.5 C-40. Primed structural concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra Hot asphalt Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Hot asphalt BP-AA or SBS-AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS- TA or APP-TA -225.0 C-41. Primed structural concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra Hot asphalt Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Hot asphalt SBS-TA (Optional) SBS-TA SBS-TA -232.5 C-42. Primed structural concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Hot asphalt Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Hot asphalt APP-TA (Optional) APP-TA APP-TA -240.0 C-43. Primed structural concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Hot asphalt Min. 0.25-inch DensDeck or DensDeck Prime Hot asphalt BP-AA, SBS-AA (Optional) One or more BP-AA, SBS- AA, SBS-TA or APP- TA SBS-AA, SBS- TA or APP-TA -240.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R35 for FL5680-R35 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 35: 04/11/2022 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 53 of 96 TABLE 3B: STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE AND TOP INSULATION LAYERS) SEE NOTE 16 FOR VAPOR BARRIER OPTIONS System No. Deck (Note 1) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply C-44. Primed structural concrete Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Hot asphalt Min. 0.75-inch EnergyGuard Perlite Roof Insulation (homogeneous), min. 0.5-inch Structodek High Density Fiberboard Roof Insulation or EnergyGuard Perlite Recover Board, min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Hot asphalt BP-AA or SBS-AA (Optional) One or more BP-AA, SBS- AA, SBS-TA SBS-AA, SBS- TA -255.0 C-45. Primed structural concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Hot asphalt Min. 1.5-inch EnergyGuard Composite Hot asphalt BP-AA, SBS-AA (Optional) One or more BP-AA, SBS- AA SBS-AA, SBS- TA or APP-TA -270.0 C-46. Primed structural concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Hot asphalt Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation Hot asphalt BP-AA, SBS-AA (Optional) One or more BP-AA, SBS- AA, SBS-TA or APP- TA SBS-AA, SBS- TA or APP-TA -307.5 C-47. Structural concrete Min. 0.5-inch EnergyGuard Polyiso Insulation LRF-XF Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-XF BP-AA, SBS-AA, SBS-TA or APP-TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS- TA or APP-TA -180.0 C-48. Structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH or EnergyGuard Ultra LRF-XF Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board LRF-XF BP-AA or SBS-AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS- TA or APP-TA -187.5 C-49. Structural concrete Min. 1-inch EnergyGuard Polyiso Insulation, EnergyGuard RH LRF-XF Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board, primed with Matrix 307 Premium Asphalt Primer LRF-XF SBS-TA (Optional) SBS-TA SBS-TA -210.0 C-50. Structural concrete Min. 2.0-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH or EnergyGuard Ultra LRF-XF Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board LRF-XF BP-AA or SBS-AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS- TA or APP-TA -225.0 C-51. Structural concrete Min. 2.0-inch EnergyGuard RA, EnergyGuard RH or EnergyGuard Ultra LRF-XF Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board LRF-XF SBS-TA or APP-TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS- TA or APP-TA -232.5 C-52. Structural concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH LRF-XF Min. 0.25-inch DensDeck Prime LRF-XF BP-AA, SBS-AA, SBS-TA or APP-TA (Optional) One or more BP-AA, SBS- AA, SBS-TA or APP- TA SBS-AA, SBS- TA or APP-TA -240.0 C-53. Structural concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH or EnergyGuard Ultra LRF-XF Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-XF SBS-TA, APP-TA (Optional) SBS-TA, APP-TA SBS-TA, APP- TA -240.0 C-54. Structural concrete Min. 1.5-inch EnergyGuard Ultra LRF-XF Min. 0.25-inch DensDeck Prime LRF-XF SBS-TA (Optional) SBS-TA SBS-TA -300.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R35 for FL5680-R35 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 35: 04/11/2022 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 54 of 96 TABLE 3B: STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE AND TOP INSULATION LAYERS) SEE NOTE 16 FOR VAPOR BARRIER OPTIONS System No. Deck (Note 1) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply C-55. Structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 Min. 0.25-inch DensDeck or DensDeck Prime OB500 BP-AA, SBS-AA, SBS-TA or APP-TA (Optional) One or more BP-AA, SBS- AA, SBS-TA or APP- TA SBS-AA, SBS- TA or APP-TA -150.0 C-56. Structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation OB500 BP-AA, SBS-AA (Optional) One or more BP-AA, SBS- AA, SBS-TA or APP- TA SBS-AA, SBS- TA or APP-TA -165.0 C-57. Structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 BP-AA or SBS-AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS- TA or APP-TA -187.5 C-58. Structural concrete Min. 1-inch EnergyGuard Polyiso Insulation, EnergyGuard RH OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board, primed with Matrix 307 Premium Asphalt Primer OB500 SBS-TA (Optional) SBS-TA SBS-TA -210.0 C-59. Structural concrete Min. 2.0-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 BP-AA or SBS-AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS- TA or APP-TA -225.0 C-60. Structural concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra OB500 Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 SBS-TA, APP-TA (Optional) SBS-TA, APP-TA SBS-TA, APP- TA -240.0 C-61. Structural concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra OB500 Min. 0.25-inch DensDeck Prime OB500 SBS-TA (Optional) SBS-TA SBS-TA -300.0 SELF-ADHERING BASE PLY WITH POLYISOCYANURATE BASE INSULATION LAYER C-62. Structural concrete Min. 1.5-inch EnergyGuard RH LRF-M Min. 0.5-inch EnergyGuard RH HD Polyiso Insulation, EnergyGuard HD Polyiso Cover Board, EnergyGuard HD Plus Polyiso Cover Board LRF-M SBS-SA (Optional) SBS-TA or APP-TA SBS-TA or APP-TA -97.5 C-63. Structural concrete Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra LRF-M Min. 0.25-inch SECUROCK Ultralight Coated Glass-Mat Roof Board LRF-M SBS-SA (Optional) SBS-TA, APP-TA SBS-TA, APP- TA -165.0 C-64. Structural concrete Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra LRF-M Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board (optional Matrix 307 Premium Asphalt Primer) LRF-M SBS-SA (Optional) SBS-TA, APP-TA SBS-TA, APP- TA -232.5 C-65. Structural concrete Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra LRF-M (Optional) Additional layer(s) base insulation LRF-M SBS-SA (Optional) SBS-TA, APP-TA SBS-TA, APP- TA -232.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R35 for FL5680-R35 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 35: 04/11/2022 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 55 of 96 TABLE 3B: STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE AND TOP INSULATION LAYERS) SEE NOTE 16 FOR VAPOR BARRIER OPTIONS System No. Deck (Note 1) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply C-66. Structural concrete Min. 1.5-inch EnergyGuard RH LRF-XF Min. 0.5-inch EnergyGuard HD Polyiso Cover Board, EnergyGuard HD Plus Polyiso Cover Board LRF-XF SBS-SA (Optional) SBS-TA or APP-TA SBS-TA or APP-TA -97.5 C-67. Structural concrete Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra LRF-XF Min. 0.25-inch DensDeck Prime LRF-XF SBS-SA (Optional) SBS-SA SBS-SA -152.5 C-68. Structural concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH LRF-XF Min. 0.25-inch DensDeck Prime LRF-XF SBS-SA (Optional) SBS-SA SBS-SA -152.5 C-69. Structural concrete Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra LRF-XF (Optional) Additional layer(s) base insulation LRF-XF SBS-SA (Optional) SBS-TA, APP-TA SBS-TA, APP- TA -232.5 C-70. Structural concrete Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra LRF-XF Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board (optional Matrix 307 Premium Asphalt Primer) LRF-XF SBS-SA (Optional) SBS-TA, APP-TA SBS-TA, APP- TA -232.5 C-71. Structural concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH LRF-XF Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board LRF-XF SBS-SA (Optional) SBS-TA, APP-TA SBS-TA, APP- TA -270.0 C-72. Structural concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH LRF-XF Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board; surface shall be primed with Matrix 307 Premium Asphalt Primer or ASTM D41 primer LRF-XF SBS-SA (Optional) SBS-TA, APP-TA SBS-TA, APP- TA -285.0 C-73. Structural concrete Min. 1.5-inch EnergyGuard RH OB500 Min. 0.5-inch EnergyGuard RH HD Polyiso Insulation, EnergyGuard HD Polyiso Cover Board, EnergyGuard HD Plus Polyiso Cover Board OB500 SBS-SA (Optional) SBS-TA or APP-TA SBS-TA or APP-TA -97.5 C-74. Structural concrete Min. 1-inch EnergyGuard RN OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 SBS-SA (Optional) SBS-TA, APP-TA SBS-TA, APP- TA -120.0 C-75. Structural concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 Min. 0.25-inch DensDeck OB500 SBS-SA (Optional) SBS-TA, APP-TA SBS-TA, APP- TA -122.5 C-76. Structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 Min. 0.25-inch DensDeck Prime OB500 SBS-SA (Optional) SBS-SA SBS-SA -152.5 C-77. Structural concrete Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra, min. 1- inch EnergyGuard RN or min. 1.5-inch EnergyGuard RA or EnergyGuard RH OB500 Min. 0.25-inch SECUROCK Ultralight Coated Glass-Mat Roof Board OB500 SBS-SA (Optional) SBS-TA, APP-TA SBS-TA, APP- TA -165.0 C-78. Structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 Min. 0.25-inch DensDeck; surface shall be primed with Matrix 307 Premium Asphalt Primer or ASTM D41 primer OB500 SBS-SA (Optional) SBS-TA, APP-TA SBS-TA, APP- TA -167.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R35 for FL5680-R35 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 35: 04/11/2022 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 56 of 96 TABLE 3B: STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE AND TOP INSULATION LAYERS) SEE NOTE 16 FOR VAPOR BARRIER OPTIONS System No. Deck (Note 1) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply C-79. Structural concrete Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board (optional Matrix 307 Premium Asphalt Primer) OB500 SBS-SA (Optional) SBS-TA, APP-TA SBS-TA, APP- TA -232.5 C-80. Structural concrete Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra OB500 (Optional) Additional layer(s) base insulation OB500 SBS-SA (Optional) SBS-TA, APP-TA SBS-TA, APP- TA -232.5 C-81. Structural concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 SBS-SA (Optional) SBS-TA, APP-TA SBS-TA, APP- TA -270.0 C-82. Structural concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board; surface shall be primed with Matrix 307 Premium Asphalt Primer or ASTM D41 primer OB500 SBS-SA (Optional) SBS-TA, APP-TA SBS-TA, APP- TA -285.0 VENTING SYSTEMS WITH POLYISOCYANURATE BASE INSULATION LAYER: C-83. Primed structural concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra Hot asphalt Min. 0.75-inch EnergyGuard Perlite Roof Insulation (homogeneous) Hot asphalt GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS- AA SBS-AA -90.0 C-84. Primed structural concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra Hot asphalt Min. 0.75-inch EnergyGuard Perlite Roof Insulation (homogeneous) Hot asphalt GAFGLAS Stratavent Perforated Venting Base Sheet One or more BP- AA, SBS-AA SBS-TA or APP-TA -90.0 C-85. Primed structural concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra Hot asphalt Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation Hot asphalt GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS- AA SBS-AA -90.0 C-86. Primed structural concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra Hot asphalt Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation Hot asphalt GAFGLAS Stratavent Perforated Venting Base Sheet One or more BP- AA, SBS-AA SBS-TA or APP-TA -90.0 C-87. Primed structural concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Hot asphalt (Optional) Additional layer(s) base insulation Hot asphalt GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS- AA SBS-AA -150.0 C-88. Primed structural concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Hot asphalt (Optional) Additional layer(s) base insulation Hot asphalt GAFGLAS Stratavent Perforated Venting Base Sheet One or more BP- AA, SBS-AA SBS-TA or APP-TA -150.0 C-89. Primed structural concrete Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Hot asphalt (Optional) Additional layer(s) base insulation Hot asphalt GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) BP-AA, SBS-AA SBS-AA -150.0 C-90. Primed structural concrete Min. 1.5-inch EnergyGuard Ultra Hot asphalt (Optional) Additional layer(s) base insulation Hot asphalt GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS- AA SBS-AA -172.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R35 for FL5680-R35 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 35: 04/11/2022 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 57 of 96 TABLE 3B: STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE AND TOP INSULATION LAYERS) SEE NOTE 16 FOR VAPOR BARRIER OPTIONS System No. Deck (Note 1) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply C-91. Primed structural concrete Min. 1.5-inch EnergyGuard Ultra Hot asphalt (Optional) Additional layer(s) base insulation Hot asphalt GAFGLAS Stratavent Perforated Venting Base Sheet One or more BP- AA, SBS-AA SBS-TA or APP-TA -172.5 C-92. Primed structural concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra Hot asphalt Min. 0.25-inch DensDeck or DensDeck Prime Hot asphalt GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS- AA SBS-AA -240.0 C-93. Primed structural concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra Hot asphalt Min. 0.25-inch DensDeck or DensDeck Prime Hot asphalt GAFGLAS Stratavent Perforated Venting Base Sheet One or more BP- AA, SBS-AA SBS-TA or APP-TA -240.0 C-94. Structural concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH LRF-XF (Optional) Additional layer(s) base insulation LRF-XF GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS- AA SBS-AA -150.0 C-95. Structural concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH LRF-XF (Optional) Additional layer(s) base insulation LRF-XF GAFGLAS Stratavent Perforated Venting Base Sheet One or more BP- AA, SBS-AA SBS-TA or APP-TA -150.0 C-96. Structural concrete Min. 1.5-inch EnergyGuard Ultra LRF-XF (Optional) Additional layer(s) base insulation LRF-XF GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS- AA SBS-AA -172.5 C-97. Structural concrete Min. 1.5-inch EnergyGuard Ultra LRF-XF (Optional) Additional layer(s) base insulation LRF-XF GAFGLAS Stratavent Perforated Venting Base Sheet One or more BP- AA, SBS-AA SBS-TA or APP-TA -172.5 C-98. Structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation LRF-XF Min. 0.25-inch DensDeck Prime LRF-XF GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS- AA SBS-AA -180.0 C-99. Structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation LRF-XF Min. 0.25-inch DensDeck Prime LRF-XF GAFGLAS Stratavent Perforated Venting Base Sheet One or more BP- AA, SBS-AA SBS-TA or APP-TA -180.0 C-100. Structural concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH or EnergyGuard Ultra LRF-XF Min. 0.25-inch DensDeck Prime LRF-XF GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS- AA SBS-AA -240.0 C-101. Structural concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH or EnergyGuard Ultra LRF-XF Min. 0.25-inch DensDeck Prime LRF-XF GAFGLAS Stratavent Perforated Venting Base Sheet One or more BP- AA, SBS-AA SBS-TA or APP-TA -240.0 C-102. Structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra OB500 Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation OB500 GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS- AA SBS-AA -90.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R35 for FL5680-R35 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 35: 04/11/2022 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 58 of 96 TABLE 3B: STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE AND TOP INSULATION LAYERS) SEE NOTE 16 FOR VAPOR BARRIER OPTIONS System No. Deck (Note 1) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply C-103. Structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra OB500 Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation OB500 GAFGLAS Stratavent Perforated Venting Base Sheet One or more BP- AA, SBS-AA SBS-TA or APP-TA -90.0 C-104. Structural concrete Min. 1.5-inch EnergyGuard Ultra OB500 (Optional) Additional layer(s) base insulation OB500 GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS- AA SBS-AA -150.0 C-105. Structural concrete Min. 1.5-inch EnergyGuard Ultra OB500 (Optional) Additional layer(s) base insulation OB500 GAFGLAS Stratavent Perforated Venting Base Sheet One or more BP- AA, SBS-AA SBS-TA or APP-TA -150.0 C-106. Structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra OB500 Min. 0.25-inch DensDeck or DensDeck Prime OB500 GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS- AA SBS-AA -150.0 C-107. Structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra OB500 Min. 0.25-inch DensDeck or DensDeck Prime OB500 GAFGLAS Stratavent Perforated Venting Base Sheet One or more BP- AA, SBS-AA SBS-TA or APP-TA -150.0 C-108. Structural concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 (Optional) Additional layer(s) base insulation OB500 GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS- AA SBS-AA -150.0 C-109. Structural concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 (Optional) Additional layer(s) base insulation OB500 GAFGLAS Stratavent Perforated Venting Base Sheet One or more BP- AA, SBS-AA SBS-TA or APP-TA -150.0 COLD-APPLIED SYSTEMS WITH POLYISOCYANURATE BASE INSULATION LAYER: C-110. Structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RH LRF-M, M- OSFA Min. 0.5-inch EnergyGuard RH HD Polyiso Insulation, EnergyGuard HD Polyiso Cover Board, EnergyGuard HD Plus Polyiso Cover Board LRF-M, M- OSFA SBS-CA or SBS-CA1 None SBS-CA or SBS-CA1 -97.5 C-111. Structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RH LRF-XF Min. 0.5-inch EnergyGuard HD Polyiso Cover Board, EnergyGuard HD Plus Polyiso Cover Board LRF-XF SBS-CA or SBS-CA1 None SBS-CA or SBS-CA1 -97.5 C-112. Structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH LRF-XF Min. 0.25-inch DensDeck Prime LRF-XF SBS-CA1 None SBS-CA1 -127.5 C-113. Structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH LRF-XF Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board LRF-XF SBS-CA1 None SBS-CA1 -172.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R35 for FL5680-R35 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 35: 04/11/2022 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 59 of 96 TABLE 3B: STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE AND TOP INSULATION LAYERS) SEE NOTE 16 FOR VAPOR BARRIER OPTIONS System No. Deck (Note 1) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply C-114. Structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation OB500 SBS-CA None SBS-CA -45.0 C-115. Structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RH OB500 Min. 0.5-inch EnergyGuard RH HD Polyiso Insulation, EnergyGuard HD Polyiso Cover Board, EnergyGuard HD Plus Polyiso Cover Board OB500 SBS-CA or SBS-CA1 None SBS-CA or SBS-CA1 -97.5 C-116. Structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 Min. 0.25-inch DensDeck Prime OB500 SBS-CA1 None SBS-CA1 -127.5 C-117. Structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 SBS-CA1 None SBS-CA1 -172.5 HYBRID COLD/HOT-APPLIED SYSTEMS WITH POLYISOCYANURATE BASE INSULATION LAYER: C-118. Primed structural concrete Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Hot asphalt Min. 0.75-inch EnergyGuard Perlite Roof Insulation (homogeneous), min. 0.5-inch Structodek High Density Fiberboard Roof Insulation or EnergyGuard Perlite Recover Board, min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Hot asphalt BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -255.0 C-119. Structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation LRF-XF Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-XF BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -180.0 C-120. Structural concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH LRF-XF Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-XF BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -240.0 C-121. Structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 Min. 0.25-inch DensDeck Prime OB500 BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -127.5 C-122. Structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -172.5 CONVENTIONAL SYSTEMS WITH POLYSTYRENE BASE INSULATION LAYER: C-123. Structural concrete Min. 2-inch Styrofoam Brand Roofmate or Highload 60 OB500 Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 SBS-TA, APP-TA (Optional) SBS-TA, APP-TA SBS-TA, APP- TA -240.0 C-124. Structural concrete Min. 2-inch Styrofoam Brand Roofmate or Highload 60 OB500 Min. 0.25-inch DensDeck or DensDeck Prime OB500 BP-AA, SBS-AA, SBS-TA or APP-TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS- TA or APP-TA -277.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R35 for FL5680-R35 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 35: 04/11/2022 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 60 of 96 TABLE 3B: STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE AND TOP INSULATION LAYERS) SEE NOTE 16 FOR VAPOR BARRIER OPTIONS System No. Deck (Note 1) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply SELF-ADHERING BASE PLY WITH POLYSTYRENE BASE INSULATION LAYER: C-125. Structural concrete Min. 2-inch Styrofoam Brand Roofmate or Highload 60 OB500 Min. 0.25-inch DensDeck Prime OB500 SBS-SA (Optional) SBS-SA SBS-SA -152.5 TABLE 3C: STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE F: NON-INSULATED, BONDED ROOF COVER System No. Deck (Note 1) Primer Roof Cover (Note 15) MDP (psf) Base Ply Ply Cap Ply CONVENTIONAL SYSTEMS: C-126. Structural concrete Matrix 307 Premium Asphalt Primer or ASTM D41 primer APP-TA (Optional) APP-TA APP-TA -90.0 C-127. Structural concrete Matrix 307 Premium Asphalt Primer or ASTM D41 primer None None SBS-TA -283.1 C-128. Structural concrete Matrix 307 Premium Asphalt Primer or ASTM D41 primer BP-AA, SBS-AA BP-AA, SBS-AA SBS-AA -442.5 C-129. Structural concrete (Optional) Matrix 307 Premium Asphalt Primer or ASTM D41 primer SBS-TA (Optional) SBS-TA SBS-TA -465.0 SELF-ADHERING BASE PLY: C-130. Structural concrete Matrix 307 Premium Asphalt Primer or ASTM D41 primer SBS-SA (Optional) SBS-SA SBS-SA -72.5 C-131. Structural concrete Matrix 307 Premium Asphalt Primer or ASTM D41 primer SBS-SA (Optional) SBS-TA or APP-TA SBS-TA or APP-TA -140.0 C-132. Structural concrete GAF SA Primer at 0.7 gal/square. SBS-SA None SBS-SA -287.5 VENTING SYSTEMS: C-133. Structural concrete Matrix 307 Premium Asphalt Primer or ASTM D41 primer GAFGLAS Stratavent Perforated Venting Base Sheet BP-AA, SBS-AA SBS-AA -185.0 COLD-APPLIED SYSTEMS: C-134. Structrual concrete Matrix 307 Premium Asphalt Primer or ASTM D41 primer BP-AA, BP-CA, SBS-CA (Optional) SBS-CA SBS-CA -307.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R35 for FL5680-R35 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 35: 04/11/2022 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 61 of 96 TABLE 4A: LIGHTWEIGHT INSULATING CONCRETE OVER STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER SEE NOTE 16A FOR VAPOR BARRIER OPTIONS System No. Deck (Note 1) Lightweight Concrete (Note 14) Base Insulation Layer Coverboard Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply ELASTIZELL (NOA 18-0208.03): LWC-1. Structural concrete Elastizell Range II Lightweight Insulating Concrete (min. 200 psi) (Optional) Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra OB500 Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation OB500 BP-AA, SBS-AA (Optional) One or more BP-AA, SBS- AA, SBS-TA or APP- TA SBS-AA, SBS- TA or APP-TA -225.0 LWC-2. Structural concrete Elastizell Range II Lightweight Insulating Concrete (min. 200 psi) (Optional) Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra OB500 Min. 0.25-inch DensDeck, DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 BP-AA, SBS-AA, SBS-TA or APP- TA (Optional) One or more BP-AA, SBS- AA, SBS-TA or APP- TA SBS-AA, SBS- TA or APP-TA -225.0 LWC-3. Structural concrete Elastizell Range II Lightweight Insulating Concrete (min. 200 psi) Min. 2.0-inch, min. 1.0 pcf, Insulfoam OB500 Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation OB500 BP-AA, SBS-AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS- TA or APP-TA -120.0 LWC-4. Structural concrete Elastizell Range II Lightweight Insulating Concrete (min. 200 psi) Min. 2-inch Styrofoam Brand Roofmate or Highload 60 OB500 Min. 0.25-inch DensDeck or DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 BP-AA, SBS-AA, SBS-TA or APP- TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS- TA or APP-TA -225.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R35 for FL5680-R35 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 35: 04/11/2022 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 62 of 96 TABLE 4B: LIGHTWEIGHT INSULATING CONCRETE OVER STEEL OR STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER SEE NOTE 16A FOR VAPOR BARRIER OPTIONS System No. Deck (Note 1) Lightweight Concrete (Note 14) Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 15) MDP (psf) Type Fasteners (Note 11) Attach Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply CELCORE (FL2037): CONVENTIONAL SYSTEMS: LWC-5. Min. 22 ga. type B, Grade 33 vented steel; 5-ft spans or min. 2,500 psi structural concrete Celcore Cellular Concrete (min. 300 psi) with min. 1 pcf EPS board and min. 2-inch thick top coat GAFGLAS #75 Base Sheet, Tri- Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, Stratavent Nailable Venting Base Sheet Drill-Tec Base Sheet Fastener (1.7 in.) 7-inch o.c. at the 3-inch lap and 7-inch o.c. in two equally spaced, staggered center rows Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation or EnergyGuard RH Polyiso Hot asphalt Min. 0.75-inch EnergyGuard Perlite Roof Insulation (homogeneous), Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation or EnergyGuard Perlite Recover Board Hot asphalt BP-AA, SBS-AA (Optional) BP-AA, SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -75.0 LWC-6. Min. 22 ga. type B, Grade 33 vented steel; 5-ft spans or min. 2,500 psi structural concrete Celcore Cellular Concrete (min. 300 psi) with min. 1 pcf EPS board and min. 2-inch thick top coat GAFGLAS #75 Base Sheet, Tri- Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, Stratavent Nailable Venting Base Sheet Drill-Tec Base Sheet Fastener (1.7 in.) 7-inch o.c. at the 3-inch lap and 7-inch o.c. in two equally spaced, staggered center rows Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation or EnergyGuard RH Polyiso Hot asphalt Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Hot asphalt BP-AA, SBS-AA, SBS-TA, APP-TA (Optional) BP-AA, SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -75.0 VENTING SYSTEMS: LWC-7. Min. 22 ga. type B, Grade 33 vented steel; 5-ft spans or min. 2,500 psi structural concrete Celcore Cellular Concrete (min. 300 psi) with min. 1 pcf EPS board and min. 2-inch thick top coat GAFGLAS #75 Base Sheet, Tri- Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, Stratavent Nailable Venting Base Sheet Drill-Tec Base Sheet Fastener (1.7 in.) 7-inch o.c. at the 3-inch lap and 7-inch o.c. in two equally spaced, staggered center rows Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation or EnergyGuard RH Polyiso Hot asphalt (Optional) Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Hot asphalt GAFGLAS Stratavent Perforate d Venting Base Sheet BP-AA, SBS-AA SBS-AA, SBS-TA, APP-TA -75.0* NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R35 for FL5680-R35 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 35: 04/11/2022 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 63 of 96 TABLE 4C: LIGHTWEIGHT INSULATING CONCRETE OVER STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE E-2: NON-INSULATED, MECHANICALY ATTACHED BASE SHEET, BONDED ROOF COVER SEE NOTE 16A FOR VAPOR BARRIER OPTIONS System No. Deck (Note 1) Lightweight Concrete (Note 14) Base Sheet Roof Cover (Note 15) MDP (psf) Type Fastener (Note 11) Attachment Base Ply Cap Ply CELCORE (FL2037): CONVENTIONAL SYSTEMS: LWC-8. Min. 22 ga. type B, Grade 33 vented steel; 6 ft spans or min. 2,500 psi structural concrete Celcore Cellular Concrete (min. 200 psi) with min. 1 pcf EPS board and min. 2- inch thick top coat GAFGLAS Stratavent Nailable Venting Base Sheet Drill-Tec Base Sheet Fastener (1.7 in.) or Drill-Tec Base Sheet Fastener E (1.7 in.) 9-inch o.c. at min. 2-inch laps and 18-inch o.c. in two (2), equally spaced, staggered center rows SBS-TA SBS-TA -45.0 LWC-9. Min. 22 ga. type B, Grade 33 vented steel; 5-ft spans or min. 2,500 psi structural concrete Celcore Cellular Concrete (min. 200 psi) with min. 1 pcf EPS board and min. 2- inch thick top coat Ruberoid Mop Granule, Tri-Ply SBS Granule Cap Sheet (granules down) Drill-Tec Locking Impact Nail 7-inch o.c. at min. 4-inch side laps and 7-inch o.c. in two, equally spaced staggered center rows. BP-AA or SBS- AA SBS-AA, SBS-TA or APP- TA -75.0 LWC-10. Min. 22 ga. type B, Grade 33 vented steel; 5-ft spans or min. 2,500 psi structural concrete Celcore Cellular Concrete (min. 300 psi) with min. 1 pcf EPS board and min. 2- inch thick top coat GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet Drill-Tec Base Sheet Fastener (1.7) 7-inch o.c. at min. 3-inch side laps and 7-inch o.c. in two, equally spaced staggered center rows. Two plies BP- AA or SBS-AA SBS-AA -75.0 HYBRID HOT/COLD-APPLIED SYSTEMS: LWC-11. Min. 22 ga., type B, Grade 33 steel; 6 ft spans or min. 2,500 psi structural concrete Celcore Cellular Concrete (min. 300 psi) with min. 1 pcf EPS board and min. 2- inch thick top coat GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet Drill-Tec Base Sheet Fastener (1.7) 12-inch o.c. at min. 2-inch side laps and 12-inch o.c. at three equally spaced staggered center rows. BP-AA or SBS- AA SBS-CA1 -45.0 LWC-12. Min. 22 ga., type B, Grade 33 steel; 6 ft spans or min. 2,500 psi structural concrete Celcore Cellular Concrete (min. 300 psi) with min. 1 pcf EPS board and min. 2- inch thick top coat GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet Drill-Tec Base Sheet Fastener (1.7) 9-inch o.c. at min. 2-inch side laps and 9-inch o.c. at two equally spaced staggered center rows. BP-AA or SBS- AA SBS-CA1 -45.0 LWC-13. Min. 22 ga., type B, Grade 33 steel; 6 ft spans or min. 2,500 psi structural concrete Celcore Cellular Concrete (min. 300 psi) with min. 1 pcf EPS board and min. 2- inch thick top coat GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet Drill-Tec Base Sheet Fastener (1.7) 7.5-inch o.c. at min. 2-inch side laps and 7.5-inch o.c. at one center row. BP-AA or SBS- AA SBS-CA1 -45.0 LWC-14. Min. 22 ga., type B, Grade 33 steel; 6 ft spans or min. 2,500 psi structural concrete Celcore Cellular Concrete (min. 300 psi) with min. 1 pcf EPS board and min. 2- inch thick top coat GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet Drill-Tec Base Sheet Fastener (1.7) 9-inch o.c. at min. 3-inch side laps and 18-inch o.c. at two equally spaced staggered center rows. BP-AA or SBS- AA SBS-CA1 -45.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R35 for FL5680-R35 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 35: 04/11/2022 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 64 of 96 TABLE 4C: LIGHTWEIGHT INSULATING CONCRETE OVER STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE E-2: NON-INSULATED, MECHANICALY ATTACHED BASE SHEET, BONDED ROOF COVER SEE NOTE 16A FOR VAPOR BARRIER OPTIONS System No. Deck (Note 1) Lightweight Concrete (Note 14) Base Sheet Roof Cover (Note 15) MDP (psf) Type Fastener (Note 11) Attachment Base Ply Cap Ply LWC-15. Min. 22 ga., type B, Grade 33 steel; 5 ft spans or min. 2,500 psi structural concrete Celcore Cellular Concrete (min. 300 psi) with min. 1 pcf EPS board and min. 2- inch thick top coat GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet Drill-Tec Base Sheet Fastener (1.7) 7-inch o.c. at min. 3-inch side laps and 7-inch o.c. at two equally spaced staggered center rows. BP-AA or SBS- AA SBS-CA1 -75.0 ELASTIZELL (NOA 18-0208.03): LWC-16. Min. 22 ga. type B, Grade 33 vented steel; 6 ft spans or min. 2,500 psi structural concrete Elastizell Range II Lightweight Insulating Concrete (min. 200 psi) with min. 1 pcf EPS board and min. 2-inch thick top coat GAFGLAS Stratavent Nailable Venting Base Sheet Drill-Tec Base Sheet Fastener (1.7 in.) or Drill-Tec Base Sheet Fastener E (1.7 in.) 9-inch o.c. at min. 2-inch laps and 18-inch o.c. in two (2), equally spaced, staggered center rows SBS-TA SBS-TA -45.0 MEARLCRETE (FL13492): CONVENTIONAL SYSTEMS: LWC-17. Min. 22 ga. type B, Grade 33 vented steel; 6 ft spans or min. 2,500 psi structural concrete Mearlcrete (min. 300 psi) with min. 1 pcf EPS board and min. 2-inch thick top coat Ruberoid Mop Plus Granule (granules down) Drill-Tec Locking Impact Nail 6-inch o.c. at min. 4-inch side laps and 9-inch o.c. in two, equally spaced staggered center rows. (Optional) BP- AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP- TA -45.0 LWC-18. Min. 22 ga. type B, Grade 33 vented steel; 6 ft spans or min. 2,500 psi structural concrete Mearlcrete (min. 300 psi) with min. 1 pcf EPS board and min. 2-inch thick top coat GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet Drill-Tec Base Sheet Fastener (1.2 in.) 7.5-inch o.c. at min. 4-inch laps and 12-inch o.c. in three, equally spaced, staggered center rows (Optional) BP- AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP- TA -52.5 LWC-19. Min. 22 ga. type B, Grade 33 vented steel; 6 ft spans or min. 2,500 psi structural concrete Mearlcrete (min. 300 psi) with min. 1 pcf EPS board and min. 2-inch thick top coat GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet Drill-Tec Base Sheet Fastener (1.7 in.) or Drill-Tec Base Sheet Fastener E (1.7 in.) 7-inch o.c. at min. 4-inch laps and 7-inch o.c. in two (2), equally spaced, staggered center rows (Optional) BP- AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP- TA -52.5 LWC-20. Structural concrete Mearlcrete (min. 300 psi) with optional min. 1 pcf Corrugated EPS Holey Board and min. 2-inch thick top coat GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet Drill-Tec Base Sheet Fastener (1.7) 7-inch o.c. at min. 4-inch laps and 7-inch o.c. in two, equally spaced, staggered center rows SBS-TA SBS-TA -52.5 LWC-21. Min. 22 ga. type B, Grade 33 vented steel; 6 ft spans or min. 2,500 psi structural concrete Mearlcrete (min. 742 psi) min. 2-inch thick top coat GAFGLAS FlexPly 6, GAFGLAS FlexPly 6 M Drill-Tec Base Sheet Fastener (1.2) 7-inch o.c. at min. 4-inch side laps and 7-inch o.c. in two, equally spaced staggered center rows. (Optional) BP- AA, SBS-AA SBS-AA (polyester reinforced, D6164 only) -52.5 SELF-ADHERING BASE PLY: NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R35 for FL5680-R35 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 35: 04/11/2022 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 65 of 96 TABLE 4C: LIGHTWEIGHT INSULATING CONCRETE OVER STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE E-2: NON-INSULATED, MECHANICALY ATTACHED BASE SHEET, BONDED ROOF COVER SEE NOTE 16A FOR VAPOR BARRIER OPTIONS System No. Deck (Note 1) Lightweight Concrete (Note 14) Base Sheet Roof Cover (Note 15) MDP (psf) Type Fastener (Note 11) Attachment Base Ply Cap Ply LWC-22. Min. 22 ga. type B, Grade 33 vented steel; 6 ft spans or min. 2,500 psi structural concrete Mearlcrete (min. 300 psi) with min. 1 pcf EPS board and min. 2-inch thick top coat StormSafe Anchor Sheet Drill-Tec Base Sheet Fastener (1.2 in.) 7.5-inch o.c. at min. 4-inch laps and 12-inch o.c. in three, equally spaced, staggered center rows (Optional) SBS-SA SBS-SA -52.5 PRE-EXISTENT CELLULAR LIGHTWEIGHT CONCRETE: CONVENTIONAL SYSTEMS: LWC-23. Min. 22 ga. type BV, Grade 33 steel; 6 ft spans or min. 2,500 psi structural concrete Min 200 psi pre-existent cellular LWC Ruberoid Mop Smooth Drill-Tec XHD Fasteners with Drill- Tec Eyehook AccuSeam Plates, Drill-Tec 2-3/8 in. Barbed XHD Plates, Dekfast Galvalume Steel Round 2-3/8” 20-Ga. Barbed Plates or Trufast 2.4” Barbed Metal Seam Plates (MCRF > 345 lbf) Fasten through LWC to structural deck 18-inch o.c. within 5-inch wide, torched or heat-welded side laps (Optional) SBS-TA SBS-TA -37.5 LWC-24. Min. 22 ga. type BV, Grade 33 steel; 6 ft spans or min. 2,500 psi structural concrete Min 200 psi pre-existent cellular LWC Ruberoid HW Smooth Drill-Tec XHD Fasteners with Drill- Tec 2-3/8 in. Barbed XHD Plates or Trufast 2.4” Barbed Metal Seam Plates (MCRF > 345 lbf) Fasten through LWC to structural deck 18-inch o.c. within 5-inch wide, torched or heat-welded side laps (Optional) SBS-TA SBS-TA -37.5 LWC-25. Min. 22 ga. type B, Grade 33 steel; 6’- 6”spans or min. 2,500 psi structural concrete Min 250-300 psi pre-existent cellular LWC with min. 1 pcf EPS board and min. 2-inch thick top coat Ruberoid Mop Smooth #14 HD Drill-Tec fasteners and 2” Drill-Tec Double-Barbed Round Steel Plates Fasten through LWC to structural deck 6-inch o.c. within 4-inch heat welded side laps (Optional) SBS-TA SBS-TA -52.5 LWC-26. Min. 22 ga. type BV, Grade 33 steel; 6 ft spans, or min. 2,500 psi structural concrete Min. 340 psi, min. 2-inch thick pre- existent cellular lightweight insulating concrete; Note: To qualify the pre-existent LWIC under this assembly, the selected fastener shall achieve an average withdrawal of 60 lbf or greater when tested per ANSI/SPRI FX-1 or TAS105. GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth Drill-Tec Base Sheet Fastener (1.7 in.), Drill-Tec Base Sheet Fastener E (1.7 in.) or Drill-Tec Locking Impact Nail 7-inch o.c. at min. 4-inch side laps and 7-inch o.c. in two (2), equally spaced staggered center rows. SBS-AA, SBS- TA SBS-AA, SBS-TA, APP-TA -52.5 LWC-27. Min. 22 ga. type BV, Grade 33 steel; 6 ft spans or min. 2,500 psi structural concrete Min 200 psi pre-existent cellular LWC Ruberoid Mop Smooth Drill-Tec XHD Fasteners with Drill- Tec Eyehook AccuSeam Plates, Drill-Tec 2-3/8 in. Barbed XHD Plates, Dekfast Galvalume Steel Round 2-3/8” 20-Ga. Barbed Plates or Trufast 2.4” Barbed Metal Seam Plates (MCRF > 345 lbf) Fasten through LWC to structural deck 12-inch o.c. within 5-inch wide, torched or heat-welded side laps (Optional) SBS-TA SBS-TA -60.0 LWC-28. Min. 22 ga. type BV, Grade 33 steel; 6 ft spans or min. 2,500 psi structural concrete Min 200 psi pre-existent cellular LWC Ruberoid HW Smooth Drill-Tec XHD Fasteners with Drill- Tec 2-3/8 in. Barbed XHD Plates or Trufast 2.4” Barbed Metal Seam Plates (MCRF > 345 lbf) Fasten through LWC to structural deck 12-inch o.c. within 5-inch wide, torched or heat-welded side laps (Optional) SBS-TA SBS-TA -60.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R35 for FL5680-R35 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 35: 04/11/2022 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 66 of 96 TABLE 4C: LIGHTWEIGHT INSULATING CONCRETE OVER STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE E-2: NON-INSULATED, MECHANICALY ATTACHED BASE SHEET, BONDED ROOF COVER SEE NOTE 16A FOR VAPOR BARRIER OPTIONS System No. Deck (Note 1) Lightweight Concrete (Note 14) Base Sheet Roof Cover (Note 15) MDP (psf) Type Fastener (Note 11) Attachment Base Ply Cap Ply LWC-29. Min. 22 ga. type B, Grade 33 steel; 6 ft spans or min. 2,500 psi structural concrete Min 250-300 psi pre-existent cellular LWC with min. 1 pcf EPS board and min. 2-inch thick top coat GAFGLAS FlexPly 6, GAFGLAS FlexPly 6 M Note 2 Fasten through LWC to structural deck 12-inch o.c. at 4-inch side laps and 12-inch o.c. in two, equally spaced staggered center rows. (Optional) BP- AA, SBS-AA SBS-AA, SBS-TA -67.5 LWC-30. Min. 22 ga., type BV, Grade 40 steel at max. 6 ft spans or min. 2,500 psi structural concrete Re-Roof Only: Min. 210 psi, min. 2-inch thick pre-existent cellular lightweight insulating concrete; Note: To qualify the pre-existent LWIC under this assembly, the selected fastener shall achieve an average withdrawal of 95 lbf or greater when tested per ANSI/SPRI FX-1 or TAS105. Ruberoid 20 Smooth Drill-Tec Base Sheet Fastener (1.7 in.) or Drill-Tec Base Sheet Fastener E (1.7 in.), Drill-Tec Locking Impact Nail 7-inch o.c. at min. 4-inch laps and 7- inch o.c. in two, equally spaced, staggered center rows Ruberoid HW 25 Smooth or Ruberoid HW Smooth, torch applied SBS-TA, APP-TA -82.5 LWC-31. Min. 22 ga., type BV, Grade 40 steel at max. 6 ft spans or min. 2,500 psi structural concrete Re-Roof Only: Min. 210 psi, min. 2-inch thick pre-existent cellular lightweight insulating concrete; Note: To qualify the pre-existent LWIC under this assembly, the selected fastener shall achieve an average withdrawal of 95 lbf or greater when tested per ANSI/SPRI FX-1 or TAS105. GAFGLAS #80 Ultima Base Sheet or GAFGLAS Stratavent Nailable Venting Base Sheet Drill-Tec Base Sheet Fastener (1.7 in.), Drill-Tec Locking Impact Nail 7-inch o.c. at min. 4-inch laps and 7- inch o.c. in two, equally spaced, staggered center rows Ruberoid HW 25 Smooth or Ruberoid HW Smooth, torch applied SBS-TA, APP-TA -82.5 LWC-32. Min. 22 ga. type B, Grade 33 steel; 5-ft spans or min. 2,500 psi structural concrete Min 250 psi pre-existent cellular LWC with optional min. 1 pcf EPS board and min. 2-inch thick top coat Ruberoid HW Granule (granules down) Note 2 Fasten through LWC to structural deck 12-inch o.c. at 4-inch side laps and 12-inch o.c. in two, equally spaced staggered center rows. (Optional) SBS-TA SBS-TA (polyester, D6164 only) -97.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R35 for FL5680-R35 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 35: 04/11/2022 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 67 of 96 TABLE 4D: LIGHTWEIGHT CONCRETE OVER STEEL CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE E-1: THERMAL BARRIER TO DECK, TEMP ROOF TO THERMAL BARRIER, LWC TO TEMP ROOF, NON-INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Thermal Barrier Temp Roof Lightweight Concrete (Note 14) Base Sheet Roof Cover (Note 15) MDP (psf) Type Fasten (Note 11) Attach Base Fasten Spacing Base Ply Cap MEARLCRETE (NOA 19-0729.03): LWC-33. Min. 22 ga. type BV, Grade 33 steel; 6 ft spans Min. 0.5-inch DensDeckPrim e or SECUROCK Gypsum-Fiber Roof Board Note 2 1 per 1.6 ft2 SBS-TA Min. 300 psi, min. 2-inch thick Mearlcrete GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet Drill-Tec Base Sheet Fastener (1.7 in.) or Drill- Tec Base Sheet Fastener E (1.7 in.) 7-inch o.c. at min. 4-inch laps and 7- inch o.c. in two (2), equally spaced, staggered center rows (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -52.5 PRE-EXISTENT CELLULAR LIGHTWEIGHT CONCRETE: LWC-34. Min. 22 ga. type BV, Grade 33 steel; 6 ft spans Min. 0.5-inch DensDeckPrim e or SECUROCK Gypsum-Fiber Roof Board Note 2 1 per 1.6 ft2 SBS-TA Min. 340 psi, min. 2-inch thick pre-existent cellular lightweight insulating concrete; Note: To qualify the pre-existent LWIC under this assembly, the selected fastener shall achieve MCRF of 60 lbf or greater when tested per TAS105. GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth Drill-Tec Base Sheet Fastener (1.7 in.), Drill- Tec Base Sheet Fastener E (1.7 in.) or Drill-Tec Locking Impact Nail 7-inch o.c. at min. 4-inch laps and 7- inch o.c. in two (2), equally spaced staggered center rows. SBS-AA, SBS-TA SBS-AA, SBS-TA, APP-TA -52.5 TABLE 4E: LIGHTWEIGHT INSULATING CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE F: NON-INSULATED, BONDED ROOF COVER SEE NOTE 16A FOR VAPOR BARRIER OPTIONS System No. Deck (Note 1) Lightweight Concrete (Note 14) Primer Roof Cover (Note 15) MDP (psf) Base Ply Ply Cap Ply CELCORE (FL2037): LWC-35. Structural concrete Min. 250-300 psi Celcore Cellular Concrete Matrix 307 Premium Asphalt Primer or ASTM D41 SBS-SA None SBS-TA -52.5 LWC-36. Structural concrete Min. 250-300 psi Celcore Cellular Concrete TOPCOAT PRECOTE SBS-SA None SBS-TA -100.0 ELASTIZELL (NOA 18-0208.03): LWC-37. Structural concrete Min. 250-300 psi Elastizell Lightweight Insulating Concrete Matrix 307 Premium Asphalt Primer or ASTM D41 SBS-SA None SBS-SA -137.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R35 for FL5680-R35 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 35: 04/11/2022 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 68 of 96 TABLE 5A: CEMENTITIOUS WOOD FIBER DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER System No. Deck (Notes 1&12) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply CONVENTIONAL SYSTEMS: CWF-1. Existing Tectum (re- roof only) Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation OB500 BP-AA, SBS-AA (Optional) One or more BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -45.0 CWF-2. Existing Tectum (re- roof only) Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 Min. 0.25-inch DensDeck, DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 BP-AA, SBS-AA, SBS- TA or APP-TA (Optional) One or more BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -45.0 SELF-ADHERING BASE PLY: CWF-3. Existing Tectum (re- roof only) Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 Min. 0.25-inch DensDeck, DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 SBS-SA (Optional) SBS-TA or APP- TA SBS-TA or APP-TA -45.0 TABLE 5B: CEMENTITIOUS WOOD FIBER DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 15) MDP (psf) Type Fasteners (Note 11) Attach Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply CONVENTIONAL SYSTEMS: CWF-4. Existing Tectum (re- roof only) GAFGLAS #75 Base Sheet, Tri- Ply #75 Base Sheet, #80 Ultima Base Sheet, Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth, Mop Smooth Min. 1.8-inch Drill-Tec Locking Impact Nail 9-inch o.c. at the 3- inch lap and 18-inch o.c. in two, equally spaced, staggered center rows (Optional) Min. 1-inch EnergyGuard Hot asphalt Min. 0.25-inch DensDeck, DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Hot asphalt BP-AA, SBS-AA, SBS-TA, APP-TA (Optional) BP-AA, SBS- AA, SBS-TA, APP-TA SBS-TA, APP-TA -45.0* CWF-5. Existing Tectum (re- roof only) GAFGLAS #75 Base Sheet, Tri- Ply #75 Base Sheet, #80 Ultima Base Sheet, Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth, Mop Smooth Min. 1.8-inch Drill-Tec Locking Impact Nail 9-inch o.c. at the 3- inch lap and 18-inch o.c. in two, equally spaced, staggered center rows (Optional) Min. 1-inch EnergyGuard Hot asphalt Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation or min. 0.75-inch EnergyGuard Perlite Roof Insulation (homogeneous) Hot asphalt BP-AA, SBS-AA (Optional) BP-AA, SBS- AA, SBS-TA, APP-TA SBS-TA, APP-TA -45.0* NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R35 for FL5680-R35 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 35: 04/11/2022 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 69 of 96 TABLE 5B: CEMENTITIOUS WOOD FIBER DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 15) MDP (psf) Type Fasteners (Note 11) Attach Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply CWF-6. Min. 2-inch Tectum I Plank GAFGLAS #75 Base Sheet, Tri- Ply #75 Base Sheet, #80 Ultima Base Sheet, Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth, Mop Smooth Min. 1.8-inch Drill-Tec Locking Impact Nail 6-inch o.c. at the 3- inch lap and 6-inch o.c. in two, equally spaced, staggered center rows Min. 1-inch EnergyGuard Polyiso Insulation Hot asphalt Min. 0.75-inch EnergyGuard Perlite Roof Insulation (homogeneous), min. 0.5-inch Structodek High Density Fiberboard Roof Insulation or EnergyGuard Perlite Recover Board or min. 0.25-inch SECUROCK Gypsum- Fiber Roof Board Hot asphalt BP-AA, SBS-AA (Optional) BP-AA, SBS- AA SBS-AA -60.0 CWF-7. Min. 2-inch Tectum I Plank GAFGLAS #75 Base Sheet, Tri- Ply #75 Base Sheet, #80 Ultima Base Sheet, Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth, Mop Smooth Min. 1.8-inch Drill-Tec Locking Impact Nail 6-inch o.c. at the 3- inch lap and 6-inch o.c. in two, equally spaced, staggered center rows Min. 1-inch EnergyGuard Polyiso Insulation Hot asphalt Min. 0.25-inch SECUROCK Gypsum- Fiber Roof Board Hot asphalt SBS-TA or APP-TA (Optional) SBS-TA or APP-TA SBS-TA or APP- TA -60.0 TABLE 5C: CEMENTITIOUS WOOD FIBER DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE E-2: NON-INSULATED, MECHANICALY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Base Sheet Roof Cover (Note 15) MDP (psf) Type Fastener (Note 11) Attachment Base Ply Cap Ply CONVENTIONAL SYSTEMS: CWF-8. Existing Tectum (re- roof only) GAFGLAS Ply 4, GAFGLAS Ply 4 M, Tri-Ply Ply 4 Ply Sheet, GAFGLAS FlexPly 6, GAFGLAS FlexPly 6 M, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet Drill-Tec LD Fasteners and Drill-Tec LD Plates 9-inch o.c. at the 4-inch lap and 12-inch o.c. in two, equally spaced, staggered center rows (Optional) BP- AA, SBS-AA or SBS-TA SBS-AA or SBS-TA -30.0 CWF-9. Existing Tectum (re- roof only) GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, #80 Ultima Base Sheet, Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth, Mop Smooth Min. 1.8-inch Drill-Tec Locking Impact Nail 9-inch o.c. at the 3-inch lap and 18-inch o.c. in two, equally spaced, staggered center rows BP-AA, SBS-AA SBS-AA, SBS-TA or APP-TA -45.0* CWF-10. Existing Tectum (re- roof only) Ruberoid 20 Smooth Drill-Tec LD Fasteners and Drill-Tec LD Plates 9-inch o.c. at the 4-inch lap and 12-inch o.c. in two, equally spaced, staggered center rows (Optional) BP- AA, SBS-AA or SBS-TA SBS-AA or SBS-TA -60.0 CWF-11. Existing Tectum (re- roof only) Ruberoid HW 25 Smooth Drill-Tec LD Fasteners and Drill-Tec LD Plates 9-inch o.c. at the 4-inch lap and 12-inch o.c. in two, equally spaced, staggered center rows (Optional) SBS- TA SBS-TA -60.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R35 for FL5680-R35 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 35: 04/11/2022 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 70 of 96 TABLE 5C: CEMENTITIOUS WOOD FIBER DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE E-2: NON-INSULATED, MECHANICALY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Base Sheet Roof Cover (Note 15) MDP (psf) Type Fastener (Note 11) Attachment Base Ply Cap Ply CWF-12. Existing Tectum (re- roof only) GAFGLAS Ply 4, GAFGLAS Ply 4 M, Tri-Ply Ply 4 Ply Sheet, GAFGLAS FlexPly 6, GAFGLAS FlexPly 6 M, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet or Ruberoid 20 Smooth Drill-Tec LD Fasteners and Drill-Tec LD Plates 7-inch o.c. at the 4-inch lap and 7-inch o.c. in two, equally spaced, staggered center rows (Optional) BP- AA, SBS-AA or SBS-TA SBS-AA or SBS-TA -67.5 CWF-13. Existing Tectum (re- roof only) Ruberoid HW 25 Smooth Drill-Tec LD Fasteners and Drill-Tec LD Plates 7-inch o.c. at the 4-inch lap and 7-inch o.c. in two, equally spaced, staggered center rows (Optional) SBS- TA SBS-TA -67.5 CWF-14. Min. 2-inch Tectum I Plank GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, #80 Ultima Base Sheet, Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth, Mop Smooth Min. 1.8-inch Drill-Tec Locking Impact Nail 6-inch o.c. at the 4-inch lap and 6-inch o.c. in two, equally spaced, staggered center rows (Optional) SBS- AA or SBS-TA SBS-AA or SBS-TA -75.0 HYBRID HOT/COLD-APPLIED SYSTEMS: CWF-15. Existing Tectum (re- roof only) GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet Min. 1.8-inch Drill-Tec Locking Impact Nail 9-inch o.c. at the 2-inch lap and 9-inch o.c. at two, equally spaced, staggered center rows BP-AA or SBS-AA SBS-CA1 -45.0* NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R35 for FL5680-R35 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 35: 04/11/2022 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 71 of 96 TABLE 6A: GYPSUM DECKS – REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER System No. Deck (Notes 1 & 12) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply CONVENTIONAL SYSTEMS: G-1. Existing sound gypsum or gypsum plank Min. 1-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 SBS-TA (Optional) SBS- TA SBS-TA -190.0 SELF-ADHERING BASE PLY: G-2. Existing sound gypsum or gypsum plank Min. 1-inch EnergyGuard Polyiso Insulation or EnergyGuard RH OB500 (Optional) Additional layer(s) of base insulation OB500 SBS-SA None SBS-SA -87.5 G-3. Existing sound gypsum or gypsum plank Min. 1-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 SBS-SA (Optional) SBS- TA, APP-TA SBS-TA, APP-TA -105.0 G-4. Existing sound gypsum or gypsum plank Min. 1-inch EnergyGuard Polyiso Insulation or EnergyGuard RN OB500 (Optional) Additional layer(s) of base insulation OB500 SBS-SA (Optional) SBS- TA, APP-TA SBS-TA, APP-TA -147.5 TABLE 6B: GYPSUM DECKS – REROOF (TEAR-OFF) SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 15) MDP (psf) Type Fasteners (Note 11) Attach Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply CONVENTIONAL SYSTEMS: G-5. Existing sound gypsum or gypsum plank GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, #80 Ultima Base Sheet, Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth, Mop Smooth Min. 1.8-inch Drill-Tec Locking Impact Nail 9-inch o.c. at the 3- inch lap and 18-inch o.c. in two, equally spaced, staggered center rows (Optional) Min. 1-inch EnergyGuard Hot asphalt Min. 0.25-inch DensDeck, DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Hot asphalt BP-AA, SBS- AA, SBS-TA, APP-TA (Optional) BP-AA, SBS-AA, SBS-TA, APP-TA SBS-TA, APP-TA -45.0* G-6. Existing sound gypsum or gypsum plank GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, #80 Ultima Base Sheet, Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth, Mop Smooth Min. 1.8-inch Drill-Tec Locking Impact Nail 9-inch o.c. at the 3- inch lap and 18-inch o.c. in two, equally spaced, staggered center rows (Optional) Min. 1-inch EnergyGuard Hot asphalt Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation or min. 0.75-inch EnergyGuard Perlite Roof Insulation (homogeneous) Hot asphalt BP-AA, SBS- AA (Optional) BP-AA, SBS-AA, SBS-TA, APP-TA SBS-TA, APP-TA -45.0* VENTING SYSTEMS: NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R35 for FL5680-R35 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 35: 04/11/2022 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 72 of 96 TABLE 6B: GYPSUM DECKS – REROOF (TEAR-OFF) SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 15) MDP (psf) Type Fasteners (Note 11) Attach Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply G-7. Existing sound gypsum or gypsum plank GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet Min. 1.8-inch Drill-Tec Locking Impact Nail or Drill-Tec Base Sheet Fastener (1.2 in) 9-inch o.c. at the 2- inch lap and 18-inch o.c. in two, equally spaced, staggered center rows Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Hot asphalt Min. 0.5-inch EnergyGuard Perlite Recover Board or min. 0.75-inch EnergyGuard Perlite Roof Insulation (homogeneous) Hot asphalt GAFGLAS Stratavent Perforated Venting Base Sheet BP-AA, SBS-AA SBS-AA or SBS- TA -45.0* G-8. Existing sound gypsum or gypsum plank GAFGLAS Stratavent Nailable Venting Base Sheet Min. 1.8-inch Drill-Tec Locking Impact Nail 9-inch o.c. at the 2- inch lap and 18-inch o.c. in two, equally spaced, staggered center rows Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Hot asphalt None N/A GAFGLAS Stratavent Perforated Venting Base Sheet Two plies SBS-AA SBS-AA -45.0* TABLE 6C: GYPSUM DECKS - REROOF (TEAR-OFF) SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer (Note 13) Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Fasteners (Note 11) Attach Base Ply Ply Cap Ply G-9. Existing sound gypsum or gypsum plank (Optional) One or more layers, any combination, loose laid Min. 0.75-inch EnergyGuard Perlite Roof Insulation (homogeneous) Drill-Tec Polymer Gyptec Fastener with Drill-Tec Gyptec Plate 1 per 1.3 ft2 BP-AA or SBS-AA (Optional) BP- AA, SBS-AA or SBS-TA SBS-AA or SBS-TA -62.5* TABLE 6D: GYPSUM DECKS - REROOF (TEAR-OFF) SYSTEM TYPE E-2: NON-INSULATED, MECHANICALY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Base Sheet Roof Cover (Note 15) MDP (psf) Type Fastener (Note 11) Attachment Base Ply Cap Ply CONVENTIONAL SYSTEMS: G-10. Existing sound gypsum or gypsum plank GAFGLAS Ply 4, GAFGLAS Ply 4 M, Tri-Ply Ply 4 Ply Sheet, GAFGLAS FlexPly 6, GAFGLAS FlexPly 6 M, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet Drill-Tec LD Fasteners and Drill-Tec LD Plates 9-inch o.c. at the 4-inch lap and 12-inch o.c. in two, equally spaced, staggered center rows (Optional) BP- AA, SBS-AA or SBS-TA SBS-AA or SBS-TA -30.0 G-11. Existing sound gypsum or gypsum plank GAFGLAS Stratavent Nailable Venting Base Sheet Drill-Tec Locking Impact Nail 9-inch o.c. at min. 2-inch laps and 18-inch o.c. in two, equally spaced, staggered center rows BP-AA, SBS-AA SBS-AA, SBS- TA or APP-TA -45.0* G-12. Existing sound gypsum or gypsum plank GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet Drill-Tec Base Sheet Fastener (1.2 in.) 9-inch o.c. at min. 2-inch laps and 18-inch o.c. in two, equally spaced, staggered center rows SBS-TA SBS-TA -45.0* NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R35 for FL5680-R35 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 35: 04/11/2022 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 73 of 96 TABLE 6D: GYPSUM DECKS - REROOF (TEAR-OFF) SYSTEM TYPE E-2: NON-INSULATED, MECHANICALY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Base Sheet Roof Cover (Note 15) MDP (psf) Type Fastener (Note 11) Attachment Base Ply Cap Ply G-13. Existing sound gypsum or gypsum plank GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet or GAFGLAS Stratavent Nailable Venting Base Sheet Drill-Tec Base Sheet Fastener (1.2 in.) 9-inch o.c. at min. 2-inch laps and 12-inch o.c. in two, equally spaced, staggered center rows (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA, SBS- TA or APP-TA -50.0* G-14. Existing sound gypsum or gypsum plank Ruberoid 20 Smooth Drill-Tec LD Fasteners and Drill-Tec LD Plates 9-inch o.c. at the 4-inch lap and 12-inch o.c. in two, equally spaced, staggered center rows (Optional) BP- AA, SBS-AA or SBS-TA SBS-AA or SBS-TA -60.0 G-15. Existing sound gypsum or gypsum plank Ruberoid HW 25 Smooth Drill-Tec LD Fasteners and Drill-Tec LD Plates 9-inch o.c. at the 4-inch lap and 12-inch o.c. in two, equally spaced, staggered center rows (Optional) SBS- TA SBS-TA -60.0 G-16. Existing sound gypsum or gypsum plank GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet or GAFGLAS Stratavent Nailable Venting Base Sheet Drill-Tec Base Sheet Fastener (1.2 in.) 9-inch o.c. at min. 2-inch laps and 9-inch o.c. in three, equally spaced, staggered center rows (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA, SBS- TA or APP-TA -57.5* G-17. Existing sound gypsum or gypsum plank GAFGLAS Ply 4, GAFGLAS Ply 4 M, Tri-Ply Ply 4 Ply Sheet, GAFGLAS FlexPly 6, GAFGLAS FlexPly 6 M, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet or Ruberoid 20 Smooth Drill-Tec LD Fasteners and Drill-Tec LD Plates 7-inch o.c. at the 4-inch lap and 7-inch o.c. in two, equally spaced, staggered center rows (Optional) BP- AA, SBS-AA or SBS-TA SBS-AA or SBS-TA -67.5 G-18. Existing sound gypsum or gypsum plank Ruberoid HW 25 Smooth Drill-Tec LD Fasteners and Drill-Tec LD Plates 7-inch o.c. at the 4-inch lap and 7-inch o.c. in two, equally spaced, staggered center rows (Optional) SBS- TA SBS-TA -67.5 HYBRID HOT/COLD-APPLIED SYSTEMS: G-19. Existing sound gypsum or gypsum plank GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet Drill-Tec Locking Impact Nail 9-inch o.c. at min. 2-inch laps and 18-inch o.c. at two, equally spaced, staggered center rows BP-AA or SBS-AA SBS-CA1 -45.0* G-20. Existing sound gypsum or gypsum plank GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet Drill-Tec Locking Impact Nail 7.5-inch o.c. at min. 2-inch laps and 7.5-inch o.c. at one center rows BP-AA or SBS-AA SBS-CA1 -45.0* NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R35 for FL5680-R35 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 35: 04/11/2022 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 74 of 96 TABLE 7A: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE INSULATION LAYER ONLY) A The reported MDP documents the allowable maximum design pressure of the new insulation, coverboard and roof cover when adhered to the substrate, irrespective of the deck type (See Note 1) or performance of the substrate (See Note 12). The deck and substrate shall be capable of resisting the project design pressure requirements, not to exceed the noted MDP, to the satisfaction of the Authority Having Jurisdiction. System No. Substrate (Notes 1 & 12) Base Insulation Layer Roof Cover (Note 15) MDP (psf)A Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply CONVENTIONAL SYSTEMS WITH BASE INSULATION LAYER ONLY R-1. Existing asphaltic roof cover Min. 0.75-inch EnergyGuard Perlite Roof Insulation (homogeneous) Hot asphalt BP-AA, SBS-AA (Optional) One or more BP- AA, SBS-AA, SBS-TA or APP- TA SBS-AA, SBS-TA or APP-TA -140.0 R-2. Existing asphaltic roof cover Min. 0.5-inch EnergyGuard Perlite Recover Board Hot asphalt BP-AA, SBS-AA (Optional) One or more BP- AA, SBS-AA, SBS-TA or APP- TA SBS-AA, SBS-TA or APP-TA -165.0 R-3. Existing asphaltic roof cover Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation Hot asphalt BP-AA, SBS-AA (Optional) One or more BP- AA, SBS-AA, SBS-TA or APP- TA SBS-AA, SBS-TA or APP-TA -165.0 R-4. Existing asphaltic roof cover Min. 1.5-inch EnergyGuard Composite Hot asphalt BP-AA, SBS-AA (Optional) One or more BP- AA, SBS-AA SBS-AA, SBS-TA or APP-TA -240.0 R-5. Existing granule surface cap sheet Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Hot asphalt SBS-TA, APP-TA (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -240.0 R-6. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-XF SBS-TA, APP-TA (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -110.0 R-7. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-XF, 6- inch o.c. SBS-TA, APP-TA (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -157.5 R-8. Existing asphaltic roof cover Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board LRF-XF SBS-TA, APP-TA (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -180.0 R-9. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-XF, 4- inch o.c. SBS-TA, APP-TA (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -180.0 R-10. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 0.25-inch DensDeck Prime LRF-XF, 4- inch o.c. SBS-TA (Optional) SBS-TA SBS-TA -200.0 R-11. Existing asphaltic roof cover Min. 0.25-inch DensDeck Prime LRF-XF SBS-TA (Optional) SBS-TA SBS-TA -245.0 R-12. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation OB500 BP-AA, SBS-AA (Optional) One or more BP- AA, SBS-AA, SBS-TA or APP- TA SBS-AA, SBS-TA or APP-TA -110.0 R-13. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 SBS-TA, APP-TA (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -110.0 R-14. Existing asphaltic roof cover Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation OB500 BP-AA, SBS-AA (Optional) One or more BP- AA, SBS-AA, SBS-TA or APP- TA SBS-AA, SBS-TA or APP-TA -120.0 R-15. Existing asphaltic roof cover Min. 0.25-inch DensDeck Prime OB500 SBS-TA (Optional) One or more SBS-TA SBS-TA -120.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R35 for FL5680-R35 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 35: 04/11/2022 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 75 of 96 TABLE 7A: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE INSULATION LAYER ONLY) A The reported MDP documents the allowable maximum design pressure of the new insulation, coverboard and roof cover when adhered to the substrate, irrespective of the deck type (See Note 1) or performance of the substrate (See Note 12). The deck and substrate shall be capable of resisting the project design pressure requirements, not to exceed the noted MDP, to the satisfaction of the Authority Having Jurisdiction. System No. Substrate (Notes 1 & 12) Base Insulation Layer Roof Cover (Note 15) MDP (psf)A Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply R-16. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation OB500, 6- inch o.c. BP-AA, SBS-AA (Optional) One or more BP- AA, SBS-AA, SBS-TA or APP- TA SBS-AA, SBS-TA or APP-TA -157.5 R-17. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board OB500, 6- inch o.c. SBS-TA, APP-TA (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -157.5 R-18. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation OB500, 4- inch o.c. BP-AA, SBS-AA (Optional) One or more BP- AA, SBS-AA, SBS-TA or APP- TA SBS-AA, SBS-TA or APP-TA -165.0 R-19. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board OB500, 4- inch o.c. SBS-TA, APP-TA (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -200.0 R-20. Existing granule surface cap sheet Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board OB500, 6- inch o.c. SBS-TA, APP-TA (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -240.0 SELF-ADHERING BASE PLY WITH BASE INSULATION LAYER ONLY R-21. Existing asphaltic roof cover Min. 1.5-inch EnergyGuard Ultra Hot asphalt SBS-SA (Optional) SBS-SA, SBS-TA, APP-TA SBS-SA, SBS-TA, APP-TA -90.0 R-22. Existing asphaltic roof cover Min. 1.5-inch EnergyGuard RN Hot asphalt SBS-SA (Optional) SBS-SA, SBS-TA, APP-TA SBS-TA, APP-TA -210.0 R-23. Existing asphaltic roof cover Min. 1.5-inch EnergyGuard RA Hot asphalt SBS-SA (Optional) SBS-SA, SBS-TA, APP-TA SBS-TA, APP-TA -217.5 R-24. Existing smooth-surface BUR over concrete deck Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra LRF-M, M- OSFA SBS-SA (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -75.0 R-25. Existing smooth surfaced BUR or granule surface roof cover Min. 0.5-inch EnergyGuard RH HD Polyiso Insulation, EnergyGuard HD Polyiso Cover Board, EnergyGuard HD Plus Polyiso Cover Board LRF-M, M- OSFA SBS-SA (Optional) SBS-TA or APP- TA SBS-TA or APP- TA -75.0 R-26. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra LRF-M SBS-SA (Optional) SBS-TA or APP- TA SBS-TA or APP- TA -110.0 R-27. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra LRF-M, 6- inch o.c. SBS-SA (Optional) SBS-TA or APP- TA SBS-TA or APP- TA -157.5 R-28. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra LRF-M, 4- inch o.c. SBS-SA (Optional) SBS-TA or APP- TA SBS-TA or APP- TA -200.0 R-29. Existing granule-surface BUR or modified bitumen or smooth-surface SBS modified bitumen over concrete deck Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra LRF-M, M- OSFA SBS-SA (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -225.0 R-30. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard RA LRF-XF SBS-SA (Optional) SBS-SA, SBS-TA, APP-TA SBS-TA, APP-TA -110.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R35 for FL5680-R35 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 35: 04/11/2022 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 76 of 96 TABLE 7A: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE INSULATION LAYER ONLY) A The reported MDP documents the allowable maximum design pressure of the new insulation, coverboard and roof cover when adhered to the substrate, irrespective of the deck type (See Note 1) or performance of the substrate (See Note 12). The deck and substrate shall be capable of resisting the project design pressure requirements, not to exceed the noted MDP, to the satisfaction of the Authority Having Jurisdiction. System No. Substrate (Notes 1 & 12) Base Insulation Layer Roof Cover (Note 15) MDP (psf)A Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply R-31. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra or Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board LRF-XF SBS-SA (Optional) SBS-TA or APP- TA SBS-TA or APP- TA -110.0 R-32. Existing asphaltic roof cover Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board LRF-XF SBS-SA (Optional) SBS-TA or APP- TA SBS-TA or APP- TA -120.0 R-33. Existing asphaltic roof cover Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board primed with Matrix 307 Premium Asphalt Primer or ASTM D41 primer LRF-XF SBS-SA (Optional) SBS-TA or APP- TA SBS-TA or APP- TA -120.0 R-34. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board LRF-XF, 6- inch o.c. SBS-SA (Optional) SBS-TA or APP- TA SBS-TA or APP- TA -137.5 R-35. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard RA LRF-XF, 6- inch o.c. SBS-SA (Optional) SBS-SA, SBS-TA, APP-TA SBS-TA, APP-TA -157.5 R-36. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 0.25-inch DensDeck primed with Matrix 307 Premium Asphalt Primer or ASTM D41 primer LRF-XF, 6- inch o.c. SBS-SA (Optional) SBS-TA or APP- TA SBS-TA or APP- TA -157.5 R-37. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra or Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board primed with Matrix 307 Premium Asphalt Primer or ASTM D41 primer LRF-XF, 6- inch o.c. SBS-SA (Optional) SBS-TA or APP- TA SBS-TA or APP- TA -157.5 R-38. Existing smooth- or granule-surface BUR or modified bitumen over concrete deck Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra LRF-XF SBS-SA (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -180.0 R-39. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra or Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board primed with Matrix 307 Premium Asphalt Primer or ASTM D41 primer LRF-XF, 4- inch o.c. SBS-SA (Optional) SBS-TA or APP- TA SBS-TA or APP- TA -180.0 R-40. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard RA LRF-XF, 4- inch o.c. SBS-SA (Optional) SBS-SA, SBS-TA, APP-TA SBS-TA, APP-TA -200.0 R-41. Existing asphaltic roof cover Min. 1.5-inch EnergyGuard RA LRF-XF SBS-SA (Optional) SBS-SA, SBS-TA, APP-TA SBS-TA, APP-TA -217.5 R-42. Existing smooth surfaced BUR / APP modified bitumen or granule surface roof cover over structural concrete deck Min. 0.5-inch EnergyGuard RH HD Polyiso Insulation, EnergyGuard HD Polyiso Cover Board, EnergyGuard HD Plus Polyiso Cover Board OB500 SBS-SA (Optional) SBS-TA or APP- TA SBS-TA or APP- TA -97.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R35 for FL5680-R35 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 35: 04/11/2022 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 77 of 96 TABLE 7A: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE INSULATION LAYER ONLY) A The reported MDP documents the allowable maximum design pressure of the new insulation, coverboard and roof cover when adhered to the substrate, irrespective of the deck type (See Note 1) or performance of the substrate (See Note 12). The deck and substrate shall be capable of resisting the project design pressure requirements, not to exceed the noted MDP, to the satisfaction of the Authority Having Jurisdiction. System No. Substrate (Notes 1 & 12) Base Insulation Layer Roof Cover (Note 15) MDP (psf)A Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply R-43. Existing asphaltic roof cover or gravel- surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min 0.5-inch Structodek High Density Fiberboard Roof Insulation OB500, 6- inch o.c. SBS-SA (Optional) SBS-SA SBS-SA -110.0 R-44. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 SBS-SA (Optional) SBS-SA SBS-SA -110.0 R-45. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 0.25-inch DensDeck primed with Matrix 307 Premium Asphalt Primer or ASTM D41 primer OB500 SBS-SA (Optional) SBS-TA or APP- TA SBS-TA or APP- TA -110.0 R-46. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard RN, Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra or Min. 0.25-inch SECUROCK Gypsum- Fiber Roof Board OB500 SBS-SA (Optional) SBS-TA or APP- TA SBS-TA or APP- TA -110.0 R-47. Existing asphaltic roof cover Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 SBS-SA (Optional) SBS-SA SBS-SA -120.0 R-48. Existing asphaltic roof cover Min. 0.25-inch DensDeck, optionally primed with Matrix 307 Premium Asphalt Primer or ASTM D41 primer OB500 SBS-SA (Optional) SBS-TA or APP- TA SBS-TA or APP- TA -120.0 R-49. Existing asphaltic roof cover Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 SBS-SA (Optional) SBS-TA or APP- TA SBS-TA or APP- TA -120.0 R-50. Existing asphaltic roof cover Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board primed with Matrix 307 Premium Asphalt Primer or ASTM D41 primer OB500 SBS-SA (Optional) SBS-TA or APP- TA SBS-TA or APP- TA -120.0 R-51. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500, 6- inch o.c. SBS-SA (Optional) SBS-SA SBS-SA -120.0 R-52. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 0.25-inch DensDeck OB500, 6- inch o.c. SBS-SA (Optional) SBS-TA or APP- TA SBS-TA or APP- TA -122.5 R-53. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500, 6- inch o.c. SBS-SA (Optional) SBS-TA or APP- TA SBS-TA or APP- TA -137.5 R-54. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 0.25-inch DensDeck primed with Matrix 307 Premium Asphalt Primer or ASTM D41 primer OB500, 6- inch o.c. SBS-SA (Optional) SBS-TA or APP- TA SBS-TA or APP- TA -157.5 R-55. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard RN, Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra or Min. 0.25-inch SECUROCK Gypsum- Fiber Roof Board primed with Matrix 307 Premium Asphalt Primer or ASTM D41 primer OB500, 6- inch o.c. SBS-SA (Optional) SBS-TA or APP- TA SBS-TA or APP- TA -157.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R35 for FL5680-R35 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 35: 04/11/2022 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 78 of 96 TABLE 7A: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE INSULATION LAYER ONLY) A The reported MDP documents the allowable maximum design pressure of the new insulation, coverboard and roof cover when adhered to the substrate, irrespective of the deck type (See Note 1) or performance of the substrate (See Note 12). The deck and substrate shall be capable of resisting the project design pressure requirements, not to exceed the noted MDP, to the satisfaction of the Authority Having Jurisdiction. System No. Substrate (Notes 1 & 12) Base Insulation Layer Roof Cover (Note 15) MDP (psf)A Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply R-56. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard RN OB500, 4- inch o.c. SBS-SA (Optional) SBS-TA or APP- TA SBS-TA or APP- TA -162.5 R-57. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 0.25-inch DensDeck primed with Matrix 307 Premium Asphalt Primer or ASTM D41 primer OB500, 4- inch o.c. SBS-SA (Optional) SBS-TA or APP- TA SBS-TA or APP- TA -167.5 R-58. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra or Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board primed with Matrix 307 Premium Asphalt Primer or ASTM D41 primer OB500, 4- inch o.c. SBS-SA (Optional) SBS-TA or APP- TA SBS-TA or APP- TA -200.0 R-59. Existing smooth- or granule-surface BUR or modified bitumen over concrete deck Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra OB500 SBS-SA (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -225.0 VENTING SYSTEMS WITH BASE INSULATION LAYER ONLY R-60. Existing asphaltic roof cover Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Hot asphalt GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP- AA, SBS-AA SBS-AA -150.0 R-61. Existing asphaltic roof cover Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Hot asphalt GAFGLAS Stratavent Perforated Venting Base Sheet One or more BP-AA, SBS- AA SBS-TA or APP- TA -150.0 R-62. Existing smooth- or granule-surface BUR, granule-surface modified bitumen or smooth-surface SBS modified bitumen over concrete deck Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Hot asphalt GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP- AA, SBS-AA SBS-AA -150.0 R-63. Existing asphaltic roof cover Min. 1.5-inch EnergyGuard Ultra Hot asphalt GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP- AA, SBS-AA SBS-AA -172.5 R-64. Existing asphaltic roof cover Min. 1.5-inch EnergyGuard Ultra Hot asphalt GAFGLAS Stratavent Perforated Venting Base Sheet One or more BP-AA, SBS- AA SBS-TA or APP- TA -172.5 R-65. Existing smooth-surface BUR over concrete deck Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra LRF-M, M- OSFA GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP- AA, SBS-AA SBS-AA -75.0 R-66. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra LRF-M GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP- AA, SBS-AA SBS-AA -110.0 R-67. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra LRF-M, 6- inch o.c. GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP- AA, SBS-AA SBS-AA -157.5 R-68. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra LRF-M, 4- inch o.c. GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP- AA, SBS-AA SBS-AA -200.0 R-69. Existing granule-surface BUR or modified bitumen or smooth-surface SBS modified bitumen over concrete deck Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra LRF-M, M- OSFA GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP- AA, SBS-AA SBS-AA -225.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R35 for FL5680-R35 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 35: 04/11/2022 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 79 of 96 TABLE 7A: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE INSULATION LAYER ONLY) A The reported MDP documents the allowable maximum design pressure of the new insulation, coverboard and roof cover when adhered to the substrate, irrespective of the deck type (See Note 1) or performance of the substrate (See Note 12). The deck and substrate shall be capable of resisting the project design pressure requirements, not to exceed the noted MDP, to the satisfaction of the Authority Having Jurisdiction. System No. Substrate (Notes 1 & 12) Base Insulation Layer Roof Cover (Note 15) MDP (psf)A Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply R-70. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra LRF-XF GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP- AA, SBS-AA SBS-AA -110.0 R-71. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra LRF-XF, 6- inch o.c. GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP- AA, SBS-AA SBS-AA -157.5 R-72. Existing smooth- or granule-surface BUR or modified bitumen over concrete deck Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra LRF-XF GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP- AA, SBS-AA SBS-AA -180.0 R-73. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra LRF-XF, 4- inch o.c. GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP- AA, SBS-AA SBS-AA -200.0 R-74. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra OB500 GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP- AA, SBS-AA SBS-AA -110.0 R-75. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra OB500, 6- inch o.c. GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP- AA, SBS-AA SBS-AA -157.5 R-76. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra OB500, 4- inch o.c. GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP- AA, SBS-AA SBS-AA -200.0 R-77. Existing smooth- or granule-surface BUR or modified bitumen over concrete deck Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra OB500 GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP- AA, SBS-AA SBS-AA -225.0 COLD-APPLIED SYSTEMS WITH BASE INSULATION LAYER ONLY R-78. Existing mineral surface cap or asphalt BUR Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Hot asphalt SBS-CA1 None SBS-CA1 -127.5 R-79. Existing mineral surface cap Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Hot asphalt SBS-CA1 None SBS-CA1 -172.5 R-80. Existing smooth surfaced BUR or granule surface roof cover Min. 0.5-inch EnergyGuard RH HD Polyiso Insulation, EnergyGuard HD Polyiso Cover Board, EnergyGuard HD Plus Polyiso Cover Board LRF-M, M- OSFA SBS-CA or SBS-CA1 None SBS-CA or SBS- CA1 -75.0 R-81. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-XF SBS-CA1 None SBS-CA1 -110.0 R-82. Existing asphalt BUR Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-XF SBS-CA1 None SBS-CA1 -120.0 R-83. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 0.25-inch DensDeck Prime LRF-XF, 6- inch o.c. SBS-CA1 None SBS-CA1 -127.5 R-84. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board LRF-XF, 6- inch o.c. SBS-CA1 None SBS-CA1 -157.5 R-85. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board LRF-XF, 4- inch o.c. SBS-CA1 None SBS-CA1 -172.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R35 for FL5680-R35 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 35: 04/11/2022 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 80 of 96 TABLE 7A: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE INSULATION LAYER ONLY) A The reported MDP documents the allowable maximum design pressure of the new insulation, coverboard and roof cover when adhered to the substrate, irrespective of the deck type (See Note 1) or performance of the substrate (See Note 12). The deck and substrate shall be capable of resisting the project design pressure requirements, not to exceed the noted MDP, to the satisfaction of the Authority Having Jurisdiction. System No. Substrate (Notes 1 & 12) Base Insulation Layer Roof Cover (Note 15) MDP (psf)A Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply R-86. Existing smooth APP, mineral surface cap, asphaltic BUR or gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 SBS-CA1 None SBS-CA1 -60.0 R-87. Existing smooth surfaced BUR / APP modified bitumen, granule surface roof cover or gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel over structural concrete deck Min. 0.5-inch EnergyGuard RH HD Polyiso Insulation, EnergyGuard HD Polyiso Cover Board, EnergyGuard HD Plus Polyiso Cover Board OB500 SBS-CA or SBS-CA1 None SBS-CA or SBS- CA1 -97.5 R-88. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 SBS-CA1 None SBS-CA1 -110.0 R-89. Existing asphalt BUR Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 SBS-CA1 None SBS-CA1 -120.0 R-90. Existing smooth APP or mineral surface cap Min. 0.25-inch DensDeck Prime OB500 SBS-CA1 None SBS-CA1 -127.5 R-91. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 0.25-inch DensDeck Prime OB500, 6- inch o.c. SBS-CA1 None SBS-CA1 -127.5 R-92. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500, 6- inch o.c. SBS-CA1 None SBS-CA1 -157.5 R-93. Existing smooth APP Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 SBS-CA1 None SBS-CA1 -165.0 R-94. Existing mineral surface cap Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 SBS-CA1 None SBS-CA1 -172.5 R-95. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500, 4- inch o.c. SBS-CA1 None SBS-CA1 -172.5 HYBRID HOT/COLD-APPLIED SYSTEMS WITH BASE INSULATION LAYER ONLY R-96. Existing mineral surface cap or asphalt BUR Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Hot asphalt BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -127.5 R-97. Existing mineral surface cap Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Hot asphalt BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -172.5 R-98. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-XF BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -110.0 R-99. Existing asphalt BUR Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-XF BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -120.0 R-100. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 0.25-inch DensDeck Prime LRF-XF, 6- inch o.c. BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -127.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R35 for FL5680-R35 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 35: 04/11/2022 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 81 of 96 TABLE 7A: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE INSULATION LAYER ONLY) A The reported MDP documents the allowable maximum design pressure of the new insulation, coverboard and roof cover when adhered to the substrate, irrespective of the deck type (See Note 1) or performance of the substrate (See Note 12). The deck and substrate shall be capable of resisting the project design pressure requirements, not to exceed the noted MDP, to the satisfaction of the Authority Having Jurisdiction. System No. Substrate (Notes 1 & 12) Base Insulation Layer Roof Cover (Note 15) MDP (psf)A Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply R-101. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board LRF-XF, 6- inch o.c. BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -157.5 R-102. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board LRF-XF, 4- inch o.c. BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -172.5 R-103. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -110.0 R-104. Existing asphalt BUR Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -120.0 R-105. Existing smooth APP or mineral surface cap Min. 0.25-inch DensDeck Prime OB500 BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -127.5 R-106. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 0.25-inch DensDeck Prime OB500, 6- inch o.c. BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -127.5 R-107. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500, 6- inch o.c. BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -157.5 R-108. Existing smooth APP Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -165.0 R-109. Existing mineral surface cap Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -172.5 R-110. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500, 4- inch o.c. BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -172.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R35 for FL5680-R35 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 35: 04/11/2022 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 82 of 96 TABLE 7B: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE AND TOP LAYER INSULATION) A The reported MDP documents the allowable maximum design pressure of the new insulation, coverboard and roof cover when adhered to the substrate, irrespective of the deck type (See Note 1) or performance of the substrate (See Note 12). The deck and substrate shall be capable of resisting the project design pressure requirements, not to exceed the noted MDP, to the satisfaction of the Authority Having Jurisdiction. Sys No. Substrate (Notes 1 & 12) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf)A Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply CONVENTIONAL SYSTEMS (BASE AND TOP LAYER INSULATION): R-111. Existing asphaltic roof cover Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Hot asphalt Min. 0.25-inch DensDeck, DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Hot asphalt BP-AA (Optional) BP-AA SBS-AA or SBS- TA -112.5 R-112. Existing asphaltic roof cover Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Hot asphalt Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Hot asphalt SBS-TA, APP-TA (Optional) SBS- TA, APP-TA SBS-TA, APP-TA -127.5 R-113. Existing smooth- or granule- surface BUR, granule-surface modified bitumen or smooth- surface SBS modified bitumen over concrete deck Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Hot asphalt Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation, EnergyGuard Perlite Recover Board, min. 0.75-inch EnergyGuard Perlite Roof Insulation, min. 0.25-inch DensDeck, DensDeck Prime, SECUROCK Gypsum Fiber Roof Board Hot asphalt BP-AA, SBS-AA (Optional) BP- AA, SBS-AA SBS-AA -150.0 R-114. Existing granule surface cap sheet Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Hot asphalt Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Hot asphalt SBS-TA, APP-TA (Optional) SBS- TA, APP-TA SBS-TA, APP-TA -172.5 R-115. Existing asphaltic roof cover Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Hot asphalt Min. 0.75-inch EnergyGuard Perlite Roof Insulation (homogeneous) Hot asphalt BP-AA, SBS-AA (Optional) One or more BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP- TA -172.5 R-116. Existing asphaltic roof cover Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Hot asphalt Min. 0.5-inch EnergyGuard Perlite Recover Board Hot asphalt BP-AA, SBS-AA (Optional) One or more BP-AA, SBS-AA SBS-AA -187.5 R-117. Existing asphaltic roof cover Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra Hot asphalt Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Hot asphalt BP-AA or SBS-AA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA, SBS-TA or APP- TA -225.0 R-118. Existing asphaltic roof cover Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra Hot asphalt Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Hot asphalt SBS-TA (Optional) SBS- TA SBS-TA -232.5 R-119. Existing asphaltic roof cover Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Hot asphalt Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Hot asphalt APP-TA (Optional) APP- TA APP-TA -240.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R35 for FL5680-R35 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 35: 04/11/2022 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 83 of 96 TABLE 7B: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE AND TOP LAYER INSULATION) A The reported MDP documents the allowable maximum design pressure of the new insulation, coverboard and roof cover when adhered to the substrate, irrespective of the deck type (See Note 1) or performance of the substrate (See Note 12). The deck and substrate shall be capable of resisting the project design pressure requirements, not to exceed the noted MDP, to the satisfaction of the Authority Having Jurisdiction. Sys No. Substrate (Notes 1 & 12) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf)A Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply R-120. Existing asphaltic roof cover Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Hot asphalt Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation or Min. 1.5-inch EnergyGuard Composite or min. 0.25-inch DensDeck Prime Hot asphalt BP-AA, SBS-AA (Optional) One or more BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP- TA -240.0 R-121. Existing smooth-surface BUR over concrete deck Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra LRF-M, M- OSFA Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation, min. 0.25-inch DensDeck, DensDeck Prime, SECUROCK Gypsum Fiber Roof Board LRF-M, M- OSFA BP-AA, SBS-AA (Optional) BP- AA, SBS-AA SBS-AA -75.0 R-122. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra LRF-M Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation, min. 0.25-inch DensDeck, DensDeck Prime, SECUROCK Gypsum Fiber Roof Board LRF-M BP-AA, SBS-AA (Optional) BP- AA, SBS-AA SBS-AA -110.0 R-123. Existing granule-surface BUR or modified bitumen or smooth-surface SBS modified bitumen over concrete deck Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra LRF-M, M- OSFA Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation, min. 0.25-inch DensDeck, DensDeck Prime, SECUROCK Gypsum Fiber Roof Board LRF-M, M- OSFA BP-AA, SBS-AA (Optional) BP- AA, SBS-AA SBS-AA -150.0 R-124. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra LRF-M, 6- inch o.c. Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation, min. 0.25-inch DensDeck, DensDeck Prime, SECUROCK Gypsum Fiber Roof Board LRF-M BP-AA, SBS-AA (Optional) BP- AA, SBS-AA SBS-AA -150.0 R-125. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH LRF-XF Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-XF BP-AA, SBS-AA, SBS- TA or APP-TA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA, SBS-TA or APP- TA -110.0 R-126. Existing smooth- or granule- surface BUR or modified bitumen over concrete deck Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra LRF-XF Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum Fiber Roof Board LRF-XF BP-AA, SBS-AA (Optional) BP- AA, SBS-AA SBS-AA -150.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R35 for FL5680-R35 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 35: 04/11/2022 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 84 of 96 TABLE 7B: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE AND TOP LAYER INSULATION) A The reported MDP documents the allowable maximum design pressure of the new insulation, coverboard and roof cover when adhered to the substrate, irrespective of the deck type (See Note 1) or performance of the substrate (See Note 12). The deck and substrate shall be capable of resisting the project design pressure requirements, not to exceed the noted MDP, to the satisfaction of the Authority Having Jurisdiction. Sys No. Substrate (Notes 1 & 12) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf)A Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply R-127. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH LRF-XF, 6- inch o.c. Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-XF BP-AA, SBS-AA, SBS- TA or APP-TA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA, SBS-TA or APP- TA -157.5 R-128. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH LRF-XF, 4- inch o.c. Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-XF BP-AA, SBS-AA, SBS- TA or APP-TA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA, SBS-TA or APP- TA -180.0 R-129. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation LRF-XF, 4- inch o.c. Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-XF BP-AA, SBS-AA, SBS- TA or APP-TA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA, SBS-TA or APP- TA -200.0 R-130. Existing asphaltic roof cover Min. 2.0-inch EnergyGuard RA, EnergyGuard RH or EnergyGuard Ultra LRF-XF Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board LRF-XF BP-AA or SBS-AA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA, SBS-TA or APP- TA -225.0 R-131. Existing asphaltic roof cover Min. 2.0-inch EnergyGuard RA, EnergyGuard RH or EnergyGuard Ultra LRF-XF Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board LRF-XF SBS-TA or APP-TA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA, SBS-TA or APP- TA -232.5 R-132. Existing asphaltic roof cover Min. 1.5-inch EnergyGuard RA, EnergyGuard RH LRF-XF Min. 0.25-inch DensDeck Prime LRF-XF BP-AA, SBS-AA, SBS- TA or APP-TA (Optional) One or more BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP- TA -240.0 R-133. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation OB500 BP-AA, SBS-AA (Optional) One or more BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP- TA -110.0 R-134. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra OB500 Min. 0.25-inch DensDeck, DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 BP-AA, SBS-AA, SBS- TA or APP-TA (Optional) One or more BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP- TA -110.0 R-135. Existing asphalt BUR or mineral surface cap Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 Min. 0.25-inch DensDeck, DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 BP-AA, SBS-AA, SBS- TA or APP-TA (Optional) One or more BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP- TA -120.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R35 for FL5680-R35 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 35: 04/11/2022 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 85 of 96 TABLE 7B: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE AND TOP LAYER INSULATION) A The reported MDP documents the allowable maximum design pressure of the new insulation, coverboard and roof cover when adhered to the substrate, irrespective of the deck type (See Note 1) or performance of the substrate (See Note 12). The deck and substrate shall be capable of resisting the project design pressure requirements, not to exceed the noted MDP, to the satisfaction of the Authority Having Jurisdiction. Sys No. Substrate (Notes 1 & 12) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf)A Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply R-136. Existing asphalt BUR or mineral surface cap Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation OB500 BP-AA, SBS-AA (Optional) One or more BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP- TA -120.0 R-137. Existing smooth APP Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 Min. 0.25-inch DensDeck or DensDeck Prime OB500 BP-AA, SBS-AA, SBS- TA or APP-TA (Optional) One or more BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP- TA -150.0 R-138. Existing smooth- or granule- surface BUR or modified bitumen over concrete deck Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra OB500 Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation, min. 0.25-inch DensDeck, DensDeck Prime, SECUROCK Gypsum Fiber Roof Board OB500 BP-AA, SBS-AA (Optional) BP- AA, SBS-AA SBS-AA -150.0 R-139. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500, 6- inch o.c. Min. 0.25-inch DensDeck or DensDeck Prime OB500 BP-AA, SBS-AA, SBS- TA or APP-TA (Optional) One or more BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP- TA -150.0 R-140. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra OB500, 6- inch o.c. Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation OB500 BP-AA, SBS-AA (Optional) One or more BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP- TA -157.5 R-141. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra OB500, 6- inch o.c. Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 SBS-TA, APP-TA (Optional) SBS- TA, APP-TA SBS-TA, APP-TA -157.5 R-142. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra OB500, 6- inch o.c. Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 BP-AA or SBS-AA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA, SBS-TA or APP- TA -157.5 R-143. Existing smooth APP Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 BP-AA, SBS-AA, SBS- TA or APP-TA (Optional) One or more BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP- TA -165.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R35 for FL5680-R35 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 35: 04/11/2022 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 86 of 96 TABLE 7B: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE AND TOP LAYER INSULATION) A The reported MDP documents the allowable maximum design pressure of the new insulation, coverboard and roof cover when adhered to the substrate, irrespective of the deck type (See Note 1) or performance of the substrate (See Note 12). The deck and substrate shall be capable of resisting the project design pressure requirements, not to exceed the noted MDP, to the satisfaction of the Authority Having Jurisdiction. Sys No. Substrate (Notes 1 & 12) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf)A Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply R-144. Existing smooth APP Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation OB500 BP-AA, SBS-AA (Optional) One or more BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP- TA -165.0 R-145. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500, 4- inch o.c. Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation OB500 BP-AA, SBS-AA (Optional) One or more BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP- TA -165.0 R-146. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra OB500, 4- inch o.c. Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 BP-AA or SBS-AA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA, SBS-TA or APP- TA -187.5 R-147. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra OB500, 4- inch o.c. Min. 0.25-inch DensDeck Prime OB500 SBS-TA (Optional) SBS- TA SBS-TA -200.0 R-148. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra OB500, 4- inch o.c. Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 SBS-TA, APP-TA (Optional) SBS- TA, APP-TA SBS-TA, APP-TA -200.0 R-149. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra OB500, 4- inch o.c. Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 BP-AA or SBS-AA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA, SBS-TA or APP- TA -200.0 R-150. Existing mineral surface cap Min. 1.5-inch EnergyGuard RA or EnergyGuard RN OB500, 6- inch o.c. Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board OB500, 6- inch o.c. BP-AA, SBS-AA, SBS- TA or APP-TA (Optional) One or more BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP- TA -240.0 SELF-ADHERING BASE PLY WITH POLYISOCYANURATE BASE INSULATION LAYER R-151. Existing smooth-surface BUR over concrete deck Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra LRF-M, M- OSFA Min. 0.25-inch SECUROCK Gypsum Fiber Roof Board LRF-M, M- OSFA SBS-SA (Optional) SBS- TA or APP-TA SBS-TA or APP- TA -75.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R35 for FL5680-R35 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 35: 04/11/2022 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 87 of 96 TABLE 7B: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE AND TOP LAYER INSULATION) A The reported MDP documents the allowable maximum design pressure of the new insulation, coverboard and roof cover when adhered to the substrate, irrespective of the deck type (See Note 1) or performance of the substrate (See Note 12). The deck and substrate shall be capable of resisting the project design pressure requirements, not to exceed the noted MDP, to the satisfaction of the Authority Having Jurisdiction. Sys No. Substrate (Notes 1 & 12) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf)A Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply R-152. Existing smooth surfaced BUR or granule surface roof cover Min. 1.5-inch EnergyGuard RH LRF-M, M- OSFA Min. 0.5-inch EnergyGuard RH HD Polyiso Insulation, EnergyGuard HD Polyiso Cover Board, EnergyGuard HD Plus Polyiso Cover Board LRF-M, M- OSFA SBS-SA (Optional) SBS- TA or APP-TA SBS-TA or APP- TA -75.0 R-153. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RH LRF-M Min. 0.5-inch EnergyGuard HD Polyiso Cover Board, EnergyGuard HD Plus Polyiso Cover Board LRF-M SBS-SA (Optional) SBS- TA or APP-TA SBS-TA or APP- TA -97.5 R-154. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra LRF-M (Optional) Additional layer(s) base insulation and/or Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board LRF-M SBS-SA (Optional) SBS- TA, APP-TA SBS-TA, APP-TA -110.0 R-155. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra LRF-M, 6- inch o.c. (Optional) Additional layer(s) base insulation and/or Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board LRF-M SBS-SA (Optional) SBS- TA, APP-TA SBS-TA, APP-TA -157.5 R-156. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra LRF-M, 4- inch o.c. (Optional) Additional layer(s) base insulation and/or Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board LRF-M SBS-SA (Optional) SBS- TA, APP-TA SBS-TA, APP-TA -200.0 R-157. Existing granule-surface BUR or modified bitumen or smooth-surface SBS modified bitumen over concrete deck Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra LRF-M, M- OSFA Min. 0.25-inch SECUROCK Gypsum Fiber Roof Board LRF-M, M- OSFA SBS-SA (Optional) SBS- TA or APP-TA SBS-TA or APP- TA -225.0 R-158. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra LRF-XF (Optional) Additional layer(s) base insulation and/or Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board LRF-XF SBS-SA (Optional) SBS- TA, APP-TA SBS-TA, APP-TA -110.0 R-159. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra LRF-XF Min. 0.25-inch DensDeck Prime LRF-XF SBS-SA (Optional) SBS- SA SBS-SA -110.0 R-160. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra LRF-XF, 6- inch o.c. Min. 0.25-inch DensDeck Prime LRF-XF SBS-SA (Optional) SBS- SA SBS-SA -152.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R35 for FL5680-R35 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 35: 04/11/2022 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 88 of 96 TABLE 7B: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE AND TOP LAYER INSULATION) A The reported MDP documents the allowable maximum design pressure of the new insulation, coverboard and roof cover when adhered to the substrate, irrespective of the deck type (See Note 1) or performance of the substrate (See Note 12). The deck and substrate shall be capable of resisting the project design pressure requirements, not to exceed the noted MDP, to the satisfaction of the Authority Having Jurisdiction. Sys No. Substrate (Notes 1 & 12) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf)A Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply R-161. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra LRF-XF, 6- inch o.c. (Optional) Additional layer(s) base insulation and/or Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board LRF-XF SBS-SA (Optional) SBS- TA, APP-TA SBS-TA, APP-TA -157.5 R-162. Existing smooth- or granule- surface BUR or modified bitumen over concrete deck Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra LRF-XF Min. 0.25-inch SECUROCK Gypsum Fiber Roof Board LRF-XF SBS-SA (Optional) SBS- TA or APP-TA SBS-TA or APP- TA -180.0 R-163. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra LRF-XF, 4- inch o.c. (Optional) Additional layer(s) base insulation LRF-XF SBS-SA (Optional) SBS- TA, APP-TA SBS-TA, APP-TA -180.0 R-164. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra LRF-XF, 4- inch o.c. Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board LRF-XF SBS-SA (Optional) SBS- TA, APP-TA SBS-TA, APP-TA -180.0 R-165. Existing smooth surfaced BUR / APP modified bitumen or granule surface roof cover over structural concrete deck Min. 1.5-inch EnergyGuard RH OB500 Min. 0.5-inch EnergyGuard RH HD Polyiso Insulation, EnergyGuard HD Polyiso Cover Board, EnergyGuard HD Plus Polyiso Cover Board OB500 SBS-SA (Optional) SBS- TA or APP-TA SBS-TA or APP- TA -97.5 R-166. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RH OB500 Min. 0.5-inch EnergyGuard HD Polyiso Cover Board, EnergyGuard HD Plus Polyiso Cover Board OB500 SBS-SA (Optional) SBS- TA or APP-TA SBS-TA or APP- TA -97.5 R-167. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra OB500 (Optional) Additional layer(s) base insulation OB500 SBS-SA (Optional) SBS- TA, APP-TA SBS-TA, APP-TA -110.0 R-168. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN, EnergyGuard Ultra OB500 Min. 0.25-inch DensDeck Prime OB500 SBS-SA (Optional) SBS- SA SBS-SA -110.0 R-169. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN, EnergyGuard Ultra OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 SBS-SA (Optional) SBS- TA, APP-TA SBS-TA, APP-TA -110.0 R-170. Existing asphaltic roof cover Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 Min. 0.25-inch DensDeck, DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 SBS-SA (Optional) SBS- SA SBS-TA or APP- TA -120.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R35 for FL5680-R35 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 35: 04/11/2022 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 89 of 96 TABLE 7B: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE AND TOP LAYER INSULATION) A The reported MDP documents the allowable maximum design pressure of the new insulation, coverboard and roof cover when adhered to the substrate, irrespective of the deck type (See Note 1) or performance of the substrate (See Note 12). The deck and substrate shall be capable of resisting the project design pressure requirements, not to exceed the noted MDP, to the satisfaction of the Authority Having Jurisdiction. Sys No. Substrate (Notes 1 & 12) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf)A Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply R-171. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RN OB500, 6- inch o.c. Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 SBS-SA (Optional) SBS- TA, APP-TA SBS-TA, APP-TA -120.0 R-172. Existing smooth APP Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 Min. 0.25-inch DensDeck Prime OB500 SBS-SA (Optional) SBS- SA SBS-SA -152.5 R-173. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500, 6- inch o.c. Min. 0.25-inch DensDeck Prime OB500 SBS-SA (Optional) SBS- SA SBS-SA -152.5 R-174. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra OB500, 6- inch o.c. (Optional) Additional layer(s) base insulation OB500 SBS-SA (Optional) SBS- TA, APP-TA SBS-TA, APP-TA -157.5 R-175. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra OB500, 6- inch o.c. Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 SBS-SA (Optional) SBS- TA, APP-TA SBS-TA, APP-TA -157.5 R-176. Existing smooth APP Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 Min. 0.25-inch DensDeck; surface shall be primed with Matrix 307 Premium Asphalt Primer or ASTM D41 primer OB500 SBS-SA (Optional) SBS- TA, APP-TA SBS-TA, APP-TA -165.0 R-177. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500, 4- inch o.c. Min. 0.25-inch DensDeck; surface shall be primed with Matrix 307 Premium Asphalt Primer or ASTM D41 primer OB500 SBS-SA (Optional) SBS- TA, APP-TA SBS-TA, APP-TA -167.5 R-178. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra OB500, 4- inch o.c. (Optional) Additional layer(s) base insulation OB500 SBS-SA (Optional) SBS- TA, APP-TA SBS-TA, APP-TA -200.0 R-179. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra OB500, 4- inch o.c. Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 SBS-SA (Optional) SBS- TA, APP-TA SBS-TA, APP-TA -200.0 R-180. Existing smooth- or granule- surface BUR or modified bitumen over concrete deck Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra OB500 Min. 0.25-inch SECUROCK Gypsum Fiber Roof Board OB500 SBS-SA (Optional) SBS- TA or APP-TA SBS-TA or APP- TA -225.0 R-181. Existing mineral surface cap Min. 1.5-inch EnergyGuard RA or EnergyGuard RN OB500, 6- inch o.c. Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board (primer optional) OB500, 6- inch o.c. SBS-SA (Optional) SBS- TA, APP-TA SBS-TA, APP-TA -240.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R35 for FL5680-R35 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 35: 04/11/2022 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 90 of 96 TABLE 7B: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE AND TOP LAYER INSULATION) A The reported MDP documents the allowable maximum design pressure of the new insulation, coverboard and roof cover when adhered to the substrate, irrespective of the deck type (See Note 1) or performance of the substrate (See Note 12). The deck and substrate shall be capable of resisting the project design pressure requirements, not to exceed the noted MDP, to the satisfaction of the Authority Having Jurisdiction. Sys No. Substrate (Notes 1 & 12) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf)A Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply VENTING SYSTEMS WITH POLYISOCYANURATE BASE INSULATION LAYER: R-182. Existing asphaltic roof cover Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra Hot asphalt Min. 0.75-inch EnergyGuard Perlite Roof Insulation (homogeneous) Hot asphalt GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS-AA SBS-AA -90.0 R-183. Existing asphaltic roof cover Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra Hot asphalt Min. 0.75-inch EnergyGuard Perlite Roof Insulation (homogeneous) Hot asphalt GAFGLAS Stratavent Perforated Venting Base Sheet One or more BP- AA, SBS-AA SBS-TA or APP- TA -90.0 R-184. Existing asphaltic roof cover Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra Hot asphalt Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation Hot asphalt GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS-AA SBS-AA -90.0 R-185. Existing asphaltic roof cover Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra Hot asphalt Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation Hot asphalt GAFGLAS Stratavent Perforated Venting Base Sheet One or more BP- AA, SBS-AA SBS-TA or APP- TA -90.0 R-186. Existing asphaltic roof cover Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Hot asphalt (Optional) Additional layer(s) base insulation Hot asphalt GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS-AA SBS-AA -150.0 R-187. Existing asphaltic roof cover Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Hot asphalt (Optional) Additional layer(s) base insulation Hot asphalt GAFGLAS Stratavent Perforated Venting Base Sheet One or more BP- AA, SBS-AA SBS-TA or APP- TA -150.0 R-188. Existing asphaltic roof cover Min. 1.5-inch EnergyGuard Ultra Hot asphalt (Optional) Additional layer(s) base insulation Hot asphalt GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS-AA SBS-AA -172.5 R-189. Existing asphaltic roof cover Min. 1.5-inch EnergyGuard Ultra Hot asphalt (Optional) Additional layer(s) base insulation Hot asphalt GAFGLAS Stratavent Perforated Venting Base Sheet One or more BP- AA, SBS-AA SBS-TA or APP- TA -172.5 R-190. Existing asphaltic roof cover Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra Hot asphalt Min. 0.25-inch DensDeck or DensDeck Prime Hot asphalt GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS-AA SBS-AA -240.0 R-191. Existing asphaltic roof cover Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra Hot asphalt Min. 0.25-inch DensDeck or DensDeck Prime Hot asphalt GAFGLAS Stratavent Perforated Venting Base Sheet One or more BP- AA, SBS-AA SBS-TA or APP- TA -240.0 R-192. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Ultra LRF-XF (Optional) Additional layer(s) base insulation LRF-XF GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS-AA SBS-AA -110.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R35 for FL5680-R35 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 35: 04/11/2022 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 91 of 96 TABLE 7B: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE AND TOP LAYER INSULATION) A The reported MDP documents the allowable maximum design pressure of the new insulation, coverboard and roof cover when adhered to the substrate, irrespective of the deck type (See Note 1) or performance of the substrate (See Note 12). The deck and substrate shall be capable of resisting the project design pressure requirements, not to exceed the noted MDP, to the satisfaction of the Authority Having Jurisdiction. Sys No. Substrate (Notes 1 & 12) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf)A Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply R-193. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Ultra LRF-XF (Optional) Additional layer(s) base insulation LRF-XF GAFGLAS Stratavent Perforated Venting Base Sheet One or more BP- AA, SBS-AA SBS-TA or APP- TA -110.0 R-194. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH or EnergyGuard Ultra LRF-XF Min. 0.25-inch DensDeck Prime LRF-XF GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS-AA SBS-AA -110.0 R-195. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH or EnergyGuard Ultra LRF-XF Min. 0.25-inch DensDeck Prime LRF-XF GAFGLAS Stratavent Perforated Venting Base Sheet One or more BP- AA, SBS-AA SBS-TA or APP- TA -110.0 R-196. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Ultra LRF-XF, 6- inch o.c. (Optional) Additional layer(s) base insulation LRF-XF GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS-AA SBS-AA -157.5 R-197. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Ultra LRF-XF, 6- inch o.c. (Optional) Additional layer(s) base insulation LRF-XF GAFGLAS Stratavent Perforated Venting Base Sheet One or more BP- AA, SBS-AA SBS-TA or APP- TA -157.5 R-198. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH or EnergyGuard Ultra LRF-XF, 6- inch o.c. Min. 0.25-inch DensDeck Prime LRF-XF GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS-AA SBS-AA -157.5 R-199. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH or EnergyGuard Ultra LRF-XF, 6- inch o.c. Min. 0.25-inch DensDeck Prime LRF-XF GAFGLAS Stratavent Perforated Venting Base Sheet One or more BP- AA, SBS-AA SBS-TA or APP- TA -157.5 R-200. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Ultra LRF-XF, 4- inch o.c. (Optional) Additional layer(s) base insulation LRF-XF GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS-AA SBS-AA -172.5 R-201. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Ultra LRF-XF, 4- inch o.c. (Optional) Additional layer(s) base insulation LRF-XF GAFGLAS Stratavent Perforated Venting Base Sheet One or more BP- AA, SBS-AA SBS-TA or APP- TA -172.5 R-202. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH or EnergyGuard Ultra LRF-XF Min. 0.25-inch DensDeck Prime LRF-XF GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS-AA SBS-AA -200.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R35 for FL5680-R35 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 35: 04/11/2022 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 92 of 96 TABLE 7B: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE AND TOP LAYER INSULATION) A The reported MDP documents the allowable maximum design pressure of the new insulation, coverboard and roof cover when adhered to the substrate, irrespective of the deck type (See Note 1) or performance of the substrate (See Note 12). The deck and substrate shall be capable of resisting the project design pressure requirements, not to exceed the noted MDP, to the satisfaction of the Authority Having Jurisdiction. Sys No. Substrate (Notes 1 & 12) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf)A Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply R-203. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH or EnergyGuard Ultra LRF-XF Min. 0.25-inch DensDeck Prime LRF-XF GAFGLAS Stratavent Perforated Venting Base Sheet One or more BP- AA, SBS-AA SBS-TA or APP- TA -200.0 R-204. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra OB500 Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation OB500 GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS-AA SBS-AA -90.0 R-205. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra OB500 Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation OB500 GAFGLAS Stratavent Perforated Venting Base Sheet One or more BP- AA, SBS-AA SBS-TA or APP- TA -90.0 R-206. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Ultra OB500 (Optional) Additional layer(s) base insulation OB500 GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS-AA SBS-AA -110.0 R-207. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Ultra OB500 (Optional) Additional layer(s) base insulation OB500 GAFGLAS Stratavent Perforated Venting Base Sheet One or more BP- AA, SBS-AA SBS-TA or APP- TA -110.0 R-208. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra OB500 Min. 0.25-inch DensDeck or DensDeck Prime OB500 GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS-AA SBS-AA -110.0 R-209. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra OB500 Min. 0.25-inch DensDeck or DensDeck Prime OB500 GAFGLAS Stratavent Perforated Venting Base Sheet One or more BP- AA, SBS-AA SBS-TA or APP- TA -110.0 R-210. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Ultra OB500, 6- inch o.c. (Optional) Additional layer(s) base insulation OB500 GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS-AA SBS-AA -150.0 R-211. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Ultra OB500, 6- inch o.c. (Optional) Additional layer(s) base insulation OB500 GAFGLAS Stratavent Perforated Venting Base Sheet One or more BP- AA, SBS-AA SBS-TA or APP- TA -150.0 R-212. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra OB500, 6- inch o.c. Min. 0.25-inch DensDeck or DensDeck Prime OB500 GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS-AA SBS-AA -150.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R35 for FL5680-R35 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 35: 04/11/2022 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 93 of 96 TABLE 7B: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE AND TOP LAYER INSULATION) A The reported MDP documents the allowable maximum design pressure of the new insulation, coverboard and roof cover when adhered to the substrate, irrespective of the deck type (See Note 1) or performance of the substrate (See Note 12). The deck and substrate shall be capable of resisting the project design pressure requirements, not to exceed the noted MDP, to the satisfaction of the Authority Having Jurisdiction. Sys No. Substrate (Notes 1 & 12) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf)A Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply R-213. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra OB500, 6- inch o.c. Min. 0.25-inch DensDeck or DensDeck Prime OB500 GAFGLAS Stratavent Perforated Venting Base Sheet One or more BP- AA, SBS-AA SBS-TA or APP- TA -150.0 COLD-APPLIED SYSTEMS WITH POLYISOCYANURATE BASE INSULATION LAYER: R-214. Existing asphalt BUR Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Hot asphalt Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Hot asphalt SBS-CA1 None SBS-CA1 -120.0 R-215. Existing mineral surface cap Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Hot asphalt Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Hot asphalt SBS-CA1 None SBS-CA1 -127.5 R-216. Existing smooth surfaced BUR or granule surface roof cover Min. 1.5-inch EnergyGuard RH LRF-M, M- OSFA Min. 0.5-inch EnergyGuard RH HD Polyiso Insulation, EnergyGuard HD Polyiso Cover Board, EnergyGuard HD Plus Polyiso Cover Board LRF-M, M- OSFA SBS-CA or SBS-CA1 None SBS-CA or SBS- CA1 -75.0 R-217. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN LRF-M Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-M SBS-CA1 None SBS-CA1 -110.0 R-218. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN LRF-M, 6- inch o.c. Min. 0.25-inch DensDeck Prime LRF-M SBS-CA1 None SBS-CA1 -127.5 R-219. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN LRF-M, 6- inch o.c. Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board LRF-M SBS-CA1 None SBS-CA1 -157.5 R-220. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN LRF-M, 4- inch o.c. Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board LRF-M SBS-CA1 None SBS-CA1 -172.5 R-221. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH LRF-XF Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-XF SBS-CA1 None SBS-CA1 -110.0 R-222. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH LRF-XF, 6- inch o.c. Min. 0.25-inch DensDeck Prime LRF-XF SBS-CA1 None SBS-CA1 -127.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R35 for FL5680-R35 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 35: 04/11/2022 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 94 of 96 TABLE 7B: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE AND TOP LAYER INSULATION) A The reported MDP documents the allowable maximum design pressure of the new insulation, coverboard and roof cover when adhered to the substrate, irrespective of the deck type (See Note 1) or performance of the substrate (See Note 12). The deck and substrate shall be capable of resisting the project design pressure requirements, not to exceed the noted MDP, to the satisfaction of the Authority Having Jurisdiction. Sys No. Substrate (Notes 1 & 12) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf)A Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply R-223. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH LRF-XF, 6- inch o.c. Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board LRF-XF SBS-CA1 None SBS-CA1 -157.5 R-224. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH LRF-XF, 4- inch o.c. Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board LRF-XF SBS-CA1 None SBS-CA1 -172.5 R-225. Existing asphaltic roof cover or gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation OB500 SBS-CA None SBS-CA -45.0 R-226. Existing smooth surfaced BUR / APP modified bitumen, granule surface roof cover or gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel over structural concrete deck Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RH OB500 Min. 0.5-inch EnergyGuard RH HD Polyiso Insulation, EnergyGuard HD Polyiso Cover Board, EnergyGuard HD Plus Polyiso Cover Board OB500 SBS-CA or SBS-CA1 None SBS-CA or SBS- CA1 -97.5 R-227. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 SBS-CA1 None SBS-CA1 -110.0 R-228. Existing asphalt BUR Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 SBS-CA1 None SBS-CA1 -120.0 R-229. Existing smooth APP or mineral surface cap Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 Min. 0.25-inch DensDeck Prime OB500 SBS-CA1 None SBS-CA1 -127.5 R-230. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500, 6- inch o.c. Min. 0.25-inch DensDeck Prime OB500 SBS-CA1 None SBS-CA1 -127.5 R-231. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500, 6- inch o.c. Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 SBS-CA1 None SBS-CA1 -157.5 R-232. Existing smooth APP Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 SBS-CA1 None SBS-CA1 -165.0 R-233. Existing mineral surface cap Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 SBS-CA1 None SBS-CA1 -172.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R35 for FL5680-R35 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 35: 04/11/2022 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 95 of 96 TABLE 7B: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE AND TOP LAYER INSULATION) A The reported MDP documents the allowable maximum design pressure of the new insulation, coverboard and roof cover when adhered to the substrate, irrespective of the deck type (See Note 1) or performance of the substrate (See Note 12). The deck and substrate shall be capable of resisting the project design pressure requirements, not to exceed the noted MDP, to the satisfaction of the Authority Having Jurisdiction. Sys No. Substrate (Notes 1 & 12) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf)A Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply R-234. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500, 4- inch o.c. Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 SBS-CA1 None SBS-CA1 -172.5 HYBRID HOT/COLD-APPLIED SYSTEMS WITH POLYISOCYANURATE BASE INSULATION LAYER: R-235. Existing asphalt BUR Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Hot asphalt Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Hot asphalt BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -120.0 R-236. Existing mineral surface cap Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Hot asphalt Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Hot asphalt BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -127.5 R-237. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN LRF-M Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-M BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -110.0 R-238. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN LRF-M, 6- inch o.c. Min. 0.25-inch DensDeck Prime LRF-M BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -127.5 R-239. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN LRF-M, 6- inch o.c. Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board LRF-M BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -157.5 R-240. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN LRF-M, 4- inch o.c. Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board LRF-M BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -172.5 R-241. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH LRF-XF Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-XF BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -110.0 R-242. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH LRF-XF, 6- inch o.c. Min. 0.25-inch DensDeck Prime LRF-XF BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -127.5 R-243. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH LRF-XF, 6- inch o.c. Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board LRF-XF BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -157.5 R-244. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH LRF-XF, 4- inch o.c. Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board LRF-XF BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -172.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R35 for FL5680-R35 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 35: 04/11/2022 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 96 of 96 TABLE 7B: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE AND TOP LAYER INSULATION) A The reported MDP documents the allowable maximum design pressure of the new insulation, coverboard and roof cover when adhered to the substrate, irrespective of the deck type (See Note 1) or performance of the substrate (See Note 12). The deck and substrate shall be capable of resisting the project design pressure requirements, not to exceed the noted MDP, to the satisfaction of the Authority Having Jurisdiction. Sys No. Substrate (Notes 1 & 12) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf)A Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply R-245. Existing asphalt BUR Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -120.0 R-246. Existing smooth APP or mineral surface cap Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 Min. 0.25-inch DensDeck Prime OB500 BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -127.5 R-247. Existing smooth APP Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -165.0 R-248. Existing mineral surface cap Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -172.5 R-249. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -110.0 R-250. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500, 6- inch o.c. Min. 0.25-inch DensDeck Prime OB500 BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -127.5 R-251. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500, 6- inch o.c. Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -157.5 R-252. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500, 4- inch o.c. Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -172.5 NOA No.: 17-1004.09 Expiration Date: 10/11/22 Approval Date: 10/12/17 Page 1 of 34 MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474 T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/economy Polyglass USA, Inc. 150 Lyon Drive Fernley, NV 89408 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami-Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Polyglass Self-Adhered Roof System over Wood Decks LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami-Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews NOA# 13-1217.01 and consists of pages 1 through 34. The submitted documentation was reviewed by Alex Tigera. By Toni Gindlesperger at 11:29 am, Jun 10, 2022By Mike Jones at 12:33 pm, Jul 01, 2022[ REVIEWED ] [L_RE_cE_1vE_o ____ ] ··~l'-------J~O~B~COPY NOA No.: 17-1004.09 Expiration Date: 10/11/22 Approval Date: 10/12/17 Page 2 of 34 ROOFING ASSEMBLY APPROVAL Category: Roofing Sub-Category: Modified Bitumen Materials SBS/APP/TPO Deck Type: Wood Maximum Design Pressure -112.5 psf TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: TABLE 1 Product Dimensions Test Specification Product Description Elastobase 65’ 2” x 3’ 3-3/8” ASTM D 6163, Type I SBS modified asphalt coated fiberglass reinforced base sheet. XtraFlex SBS Glass Base 65’ 8” x 3’ 3-3/8” ASTM D 6163, Type I SBS modified asphalt coated fiberglass reinforced base sheet. Polyglass G2 Base 108’ x 36” ASTM D 4601 Type II Asphalt-coated fiberglass reinforced base sheet Polyanchor 250’ x 48” ASTM D 4601 Type II A polymer woven, high performance, synthetic base sheet. Elastobase P 65’ 8” x 3’ 3-3/8” ASTM D 6164, Type I SBS modified asphalt coated polyester reinforced base sheet. Elastoflex SA V FR (1.5-mm) 66’ 8” x 3’ 3-3/8” ASTM D 6163, Type I Self-adhered, fire-rated, fiberglass reinforced, SBS modified bitumen membrane with a self-adhering back face and a smooth top surface. Elastoflex SA V PLUS FR 66’ 8” x 3’ 3-3/8” ASTM D 6163, Type I Self-adhered, fire-rated, fiberglass reinforced, SBS modified bitumen membrane with a self-adhering back face and a smooth top surface. Elastoflex SA V (1.5- mm) 66’ 8” x 3’ 3-3/8” ASTM D 6163, Type I Self-adhered, fiberglass reinforced, SBS modified bitumen membrane with a self-adhering back face and a smooth top surface. Elastoflex SA V PLUS 66’ 8” x 3’ 3-3/8” ASTM D 6163, Type I Self-adhered, fiberglass reinforced, SBS modified bitumen membrane with a self-adhering back face and a smooth top surface. XtraFlex SBS Base SA 66’ 8” x 3’ 3-3/8” ASTM D 6163, Type I Self-adhered, fiberglass reinforced, SBS modified bitumen membrane with a self-adhering back face and a smooth top surface. Elastoflex SA P FR 32’ 10” x 3’ 3-3/8” ASTM D 6164, Type I Self-adhered, fire-rated, polyester reinforced, SBS modified bitumen membrane with a self-adhering back face and a granule top surface. XtraFlex SBS G SA 32’ 10” x 3’ 3-3/8” ASTM D 6164, Type I Self-adhered, fire-rated, polyester reinforced, SBS modified bitumen membrane with a self-adhering back face and a granule top surface. NOA No.: 17-1004.09 Expiration Date: 10/11/22 Approval Date: 10/12/17 Page 3 of 34 Elastoflex SA P 32’ 10” x 3’ 3-3/8” ASTM D 6164, Type I Self-adhered, fiberglass reinforced, SBS modified bitumen membrane with a self-adhering back face and a granule top surface. Polyflex 32’ 10” x 3’ 3-3/8” ASTM D 6222 Torch applied, polyester reinforced, APP modified bitumen membrane with a burn off polyethylene back face and a smooth or sanded top surface. XtraFlex APP S 32’ 10” x 3’ 3-3/8” ASTM D 6222 Torch applied, polyester reinforced, APP modified bitumen membrane with a burn off polyethylene back face and a smooth or sanded top surface. Polybond 32’ 10” x 3’ 3-3/8” ASTM D 6222 Torch applied, polyester reinforced, APP modified bitumen membrane with a burn off polyethylene back face and a smooth or sanded top surface. Polyflex G 32’ 10” x 3’ 3-3/8” ASTM D 6222 Torch applied, polyester reinforced, APP modified bitumen membrane with a burn off polyethylene back face and a granule top surface. Polyflex SA P 32’ 10” x 3’ 3-3/8” ASTM D 6222, Type I Self-adhered, polyester reinforced, APP modified bitumen membrane with a self-adhering back face and a granule top surface. Polyflex SA P FR 32’ 10” x 3’ 3-3/8” ASTM D 6222, Type I Self-adhered, fire-rated, polyester reinforced, APP modified bitumen membrane with a self-adhering back face and a granule top surface. XtraFlex APP G SA 32’ 10” x 3’ 3-3/8” ASTM D 6222, Type I Self-adhered, fire-rated, polyester reinforced, APP modified bitumen membrane with a self-adhering back face and a granule top surface. Polyfresko G SBS SA 32’ 10” x 3’ 3-3/8” ASTM D 6164, Type I Self-adhered, fiberglass reinforced, SBS modified bitumen membrane with a self-adhering back face and a granule top surface. Polyfresko G SBS SA FR 32’ 10” x 3’ 3-3/8” ASTM D 6164, Type I Self-adhered, fire-rated, fiberglass reinforced, SBS modified bitumen membrane with a self-adhering back face and a granule top surface. Polyfresko G APP SA 32’ 10” x 3’ 3-3/8” ASTM D 6222, Type I Self-adhered, polyester reinforced, APP modified bitumen membrane with a self-adhering back face and a granule top surface. Polyfresko G APP SA FR 32’ 10” x 3’ 3-3/8” ASTM D 6222, Type I Self-adhered, fire-rated, polyester reinforced, APP modified bitumen membrane with a self-adhering back face and a granule top surface PolyKool 32’ 10” x 3’ 3-3/8” ASTM D6222 Type I Self-adhered, polyester reinforced, APP modified bitumen membrane with a self-adhering back face and a white film laminate on the top surface. XtraFlex Kool APP S SA 32’ 10” x 3’ 3-3/8” ASTM D6222 Type I Self-adhered, polyester reinforced, APP modified bitumen membrane with a self-adhering back face and a white film laminate on the top surface. Polyglass APP Base 65’ 8” x 3’ 3-3/8” ASTM D 6509 Type I APP modified asphalt coated fiberglass reinforced base sheet. NOA No.: 17-1004.09 Expiration Date: 10/11/22 Approval Date: 10/12/17 Page 4 of 34 PG325 Cold Process Adhesive 1, 3, 5, 50, 55 gal. or tube ASTM D3019 Type III A fibered cold process adhesive for use with roll or BUR roofing. PG100 Asphalt Primer 1, 3, 5, 50, 55 gal, tube or 17 oz. spray can ASTM D41 A penetrating solution of solvent and a blend of selected asphalts used to promote adhesion. XtraFlex 10 Asphalt Primer 1, 3, 5, 50, 55 gal, tube or 17 oz. spray can ASTM D41 A penetrating solution of solvent and a blend of selected asphalts used to promote adhesion. PG350 Mod Bit Adhesive 1, 3, 5, 50, 55 gal. or tube ASTM D3019 Type III A fibered rubberized adhesive designed for use with modified bitumen membranes. PG400 Plastic Roof Cement 1, 3, 5, 50, 55 gal. or tube ASTM D4586 ASTM D3409 A thick, fibered, rubberized flashing cement for use in dry or damp conditions. PG425 Wet/Dry Roof Cement 1, 3, 5, 50, 55 gal. or tube ASTM D4586 ASTM D3409 A thick, fibered, rubberized flashing cement for use in dry or damp conditions. PG450 Flashing Cement 1, 3, 5, 50, 55 gal. or tube ASTM D4586 A thick, fibered, rubberized flashing cement. PG500 MB Flashing Cement 1, 3, 5, 50, 55 gal. or tube ASTM D4586 A thick, fibered, rubberized flashing cement for use with modified bitumen membranes. Polyplus 35 Premium Mod Bit Adhesive 1, 3, 5, 50, 55 gal. or tube ASTM D3019 Type III A fibered rubberized adhesive designed for use with modified bitumen membranes. XtraFlex 35 Premium Mod Bit Adhesive 1, 3, 5, 50, 55 gal. or tube ASTM D3019 Type III A fibered rubberized adhesive designed for use with modified bitumen membranes. Polyplus 45 Premium Flashing Cement 1, 3, 5, 50, 55 gal. or tube ASTM D4586 A thick, fibered, rubberized flashing cement. Polyplus 50 Premium MB Flashing Cement 1, 3, 5, 50, 55 gal. or tube ASTM D4586 A thick, fibered, rubberized flashing cement for use with modified bitumen membranes. XtraFlex 50 Premium Modified Wet/Dry Cement 1, 3, 5, 50, 55 gal. or tube ASTM D4586 A thick, fibered, rubberized flashing cement for use with modified bitumen membranes. Polyplus 55 Premium Modified Flashing Cement 1, 3, 5, 50, 55 gal. or tube ASTM D4586 A mastic compound for use as a roof flashing adhesive. NOA No.: 17-1004.09 Expiration Date: 10/11/22 Approval Date: 10/12/17 Page 5 of 34 APPROVED INSULATIONS: TABLE 2 Product Name Product Description Manufacturer (With Current NOA) Polytherm-H Polyisocyanurate foam insulation Polyglass USA, Inc. Polytherm Polyisocyanurate foam insulation Polyglass USA, Inc. ACFoam-II Polyisocyanurate foam insulation Atlas Roofing Corp ACFoam-III Polyisocyanurate foam insulation Atlas Roofing Corp High Density Wood Fiberboard Wood fiber insulation board Generic DensDeck, DensDeck Prime Gypsum insulation board Georgia-Pacific Gypsum LLC H-Shield Polyisocyanurate foam insulation Hunter Panels, LLC H-Shield CG Polyisocyanurate/perlite composite insulation Hunter Panels, LLC ENRGY-3 Polyisocyanurate foam insulation Johns Manville Corp. Fesco Board Expanded mineral fiber Johns Manville Corp. Multi-Max FA-3 Polyisocyanurate foam insulation Rmax Operating, LLC. SECUROCK Gypsum-Fiber Roof Board Fiber reinforced coverboard United States Gypsum Corporation NOA No.: 17-1004.09 Expiration Date: 10/11/22 Approval Date: 10/12/17 Page 6 of 34 APPROVED FASTENERS: TABLE 3 Fastener Number Product Name Product Description Dimensions Manufacturer (With Current NOA) 1. Dekfast Fasteners 12, 14 & 15 HS Insulation fastener for wood, steel and concrete decks SFS Intec, Inc. 2. Dekfast Galvalume Steel Hex Plate Galvalume hex stress plate. 2 7/8" x 3 ¼” SFS Intec, Inc. 3. #14 Roofgrip Insulation and membrane fastener Various OMG, Inc. 4. Flat Bottom Metal Plate A2-SS aluminized steel plate 3" square OMG, Inc. 5. Trufast #14 HD Fastener Insulation fastener for steel and wood decks Altenloh, Brinck & Co. U.S., Inc. 6. Trufast 3” Metal Insulation Plate Round Galvalume AZ50 steel plate 3.23 round 3" round Altenloh, Brinck & Co. U.S., Inc. 7. Polygrip Fasteners #12, #14 & #15 Insulation fastener for wood, steel and concrete decks Various Polyglass USA, Inc 8. Polygrip Hex Plates Galvalume hex stress plate. 2 7/8" x 3 ¼” Polyglass USA, Inc NOA No.: 17-1004.09 Expiration Date: 10/11/22 Approval Date: 10/12/17 Page 7 of 34 APPROVED SURFACING: TABLE 4 Product Name Product Description Application Rate Specification Manufactur er PG200 Non-Fibered Roof Coating A non fibered asphaltic coating used to add life and rejuvenate existing BUR roofing substrates. 1½-2 gal/sq TAS 140 Polyglass USA, Inc. XtraFlex 20 Bituminous Roof Coating A non fibered asphaltic coating used to add life and rejuvenate existing BUR roofing substrates. 1½-2 gal/sq TAS 140 Polyglass USA, Inc. PG300 Fibered Roof Coating An asphalt cutback fibered roof coating. May be applied by brush or spray equipment to rejuvenate aged BUR 1½-2 gal/sq ASTM D4479 Polyglass USA, Inc. XtraFlex Bituminous Roof Coating Fibered An asphalt cutback fibered roof coating. May be applied by brush or spray equipment to rejuvenate aged BUR 1½-2 gal/sq ASTM D4479 Polyglass USA, Inc. PG600 Non-Fibered Aluminum Roof Coating Non-fibered aluminum roof coating. ½-1 gal/sq ASTM D2824 Type I Polyglass USA, Inc. PG650 Fibered Aluminum Roof Coating Fibered aluminum roof coating. 1½-2 gal/sq ASTM D2824 Type III Polyglass USA, Inc. PG700 Elastomeric Roof Coating A premium white elastomeric acrylic based roof coating (water-based). A polyester fabric may be used for reinforcement with this coating. 1-1½ gal/sq ASTM D6083 Polyglass USA, Inc. PG800 Non-Fibered Asphalt Emulsion Roof Coating An asphalt base, un-fibered clay emulsion 3 gal/sq in two coats ASTM D1227 Polyglass USA, Inc. XtraFlex 80 Emulsion Roof Coating An asphalt base, un-fibered clay emulsion 3 gal/sq in two coats ASTM D1227 Polyglass USA, Inc. PG850 Fibered Asphalt Emulsion Roof Coating An asphalt base, fibered clay emulsion 3 gal/sq in two coats ASTM D1227 Polyglass USA, Inc. Polyplus 65 Premium Fibered Aluminum Roof Coating Fibered aluminum roof coating. 1½-2 gal/sq ASTM D2824 Type III Polyglass USA, Inc. XtraFlex 65 Aluminum Roof Coating Fibered Fibered aluminum roof coating. 1½-2 gal/sq ASTM D2824 Type III Polyglass USA, Inc. Polyplus 60 Premium Non- Fibered Aluminum Roof Coating Non-fibered aluminum roof coating. ½-1 gal/sq ASTM D2824 Type I Polyglass USA, Inc. XtraFlex 60 Aluminum Roof Coating Non-fibered aluminum roof coating. ½-1 gal/sq ASTM D2824 Type I Polyglass USA, Inc. NOA No.: 17-1004.09 Expiration Date: 10/11/22 Approval Date: 10/12/17 Page 8 of 34 APPROVED SURFACING: TABLE 4 Product Name Product Description Application Rate Specification Manufactur er Polybrite 70 Premium Grade Elastomeric Roof Coating A premium white elastomeric acrylic based roof coating (water-based). A polyester fabric may be used for reinforcement with this coating. 1-1½ gal/sq ASTM D6083 Polyglass USA, Inc. XtraFlex 70 Premium Acrylic FR Roof Coating A premium white elastomeric acrylic based roof coating (water-based). A polyester fabric may be used for reinforcement with this coating. 1-1½ gal/sq ASTM D6083 Polyglass USA, Inc. Polybrite 90 High Solids Silicone Roof Coating A premium grade high solids, single component, moisture cure, fluid applied silicone coating 1.25 gal/sq ASTM D6694 Polyglass USA, Inc. XtraFlex SRC 9600 High Solids Silicone Roof Coating A premium grade high solids, single component, moisture cure, fluid applied silicone coating 1.25 gal/sq ASTM D6694 Polyglass USA, Inc. Polybrite 95 Silicone Roof Coating A single component, solvent, moisture cure silicone coating. 1.25 gal/sq ASTM D6694 Polyglass USA, Inc. XtraFlex SRC 8000 Silicone Roof Coating A single component, solvent, moisture cure silicone coating. 1.25 gal/sq ASTM D6694 Polyglass USA, Inc. Gravel To be installed in a flood coat of approved asphalt at 60 lbs/sq 400 lbs/sq N/A Generic Slag To be installed in a flood coat of approved asphalt at 60 lbs/sq 300 lbs/sq N/A Generic NOA No.: 17-1004.09 Expiration Date: 10/11/22 Approval Date: 10/12/17 Page 9 of 34 EVIDENCE SUBMITTED: Test Agency Test Name/Report Report No. Date Factory Mutual Research 4470 2W7A7.AM 08.04.94 Corporation 4450 2D5A9.AM 06.22.99 4470 3001334 02.15.00 4470 3000857 01.12.00 4470 3004091 01.12.00 4470 3012321 07.29.07 4450 3014751 08.27.03 4450 3019317 06.30.04 4470 3014692 08.05.03 Trinity | ERD TAS 114 11752.09.99-1 02.08.00 TAS 114 02764.09.05 09.09.05 TAS 114 02762.03.05 03.30.05 TAS 117(B)-ASTM D903 020841.06.04 06.02.04 TAS 114 P1734.07.06-R1 02.27.07 TAS 114 P1738.02.07 02.05.07 TAS 114 P1739.01.07 01.23.07 TAS 117(B)-ASTM D6862 C8500SC.11.07 11.30.07 ASTM D6164 / ASTM D6222 P10490.08.08 08.13.08 ASTM D6164 / ASTM D6222 P10490.10.08-R1 10.03.08 ASTM D6222 P7400.03.08-R2 10.09.08 TAS 114(D) – ASTM D1876 P10070.10.08 10.09.08 ASTM D6222 P10490.10.08-2 10.30.08 FM 4470 & TAS 114 P33970.03.11 03.15.11 ASTM D6163 / ASTM D 4601 P33960.03.11 03.15.11 TAS 114 & TAS 117 (B) 11757.12.00-1-R1 04.29.13 TAS 114 & TAS 117 (B) 11757.04.01-1-R1 04.30.13 ASTM D6164 P37590.07.13-1 07.02.13 ASTM D6164 P37590.03.13-3A 03.06.13 ASTM D6163 P37590.03.13-2-R1 02.05.13 ASTM D6222 P37590.09.13 09.12.13 ASTM D4601 / TAS 117 P45940.09.13 09.04.13 TAS 114 & FM 4474 P41630.08.13 08.06.13 TAS 114 (H) P13760.09.09 09.10.09 ASTM D4601 / TAS 117 P45970.05.14 05.12.14 PRI Construction Materials Technologies ASTM D6222 PUSA-061-02-02 01.28.08 ASTM D6222 PUSA-062-02-02 12.04.08 ASTM D6163 PUSA-064-02-02 02.27.08 ASTM D6694 PUSA-134-02-01 05.16.14 ASTM D6694 PUSA-135-02-01 05.16.14 NOA No.: 17-1004.09 Expiration Date: 10/11/22 Approval Date: 10/12/17 Page 10 of 34 APPROVED ASSEMBLIES: Membrane Type: SBS/APP Deck Type 1I: Wood, Insulated Deck Description: 19/32" or greater plywood or wood plank, fastened at 24” spans with #8 wood screws at 6” o.c.. System Type A(1): All insulation layers are adhered to a mechanically attached anchor sheet. Membrane is subsequently adhered to insulation. All General and System Limitations apply. Anchor Sheet: One ply of Elastobase, XtraFlex SBS Glass Base, Polyglass G2 Base, Polyflex*, XtraFlex APP S*, Polybond* or GAFGLAS #75 fastened to the deck as described below: *with OMG fasteners and Flat Bottom Metal Plates. Fastening #1: Attach base sheet using 11 ga. annular ring shank and 1-5/8” diameter tin caps spaced 8” o.c. in a 4” lap and 8” o.c. in three equally spaced staggered rows in the center of the sheet. Fastening #2: Attach base sheet using OMG #14 Roofgrip fasteners and Flat Bottom Metal Plates, Dekfast 14 with Galvalume Steel Hex Plates or Polygrip Fasteners #14 with Polygrip Hex Plates or Trufast #14 HD Fasteners with Trufast 3” Metal Insulation Plates spaced 12” o.c. in a 4” lap and 12” o.c. in two equally spaced staggered rows in the center of the sheet. One or more of the following Base Insulation Layer (Optional) Insulation Fasteners (Table 3) Fastener Density/ft2 Any approved Polyisocyanurate listed in Table 2 Minimum 1” thick N/A N/A Note: All insulation shall be adhered to the anchor sheet in full mopping of approved hot asphalt within the EVT range and at a rate of 20-40 lbs/100 ft2. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Insulation listed as base layer only shall be used only as base layers with a second layer of approved top layer insulation installed as the final membrane substrate. Composite insulation panels may be used as a top layer placed with the polyisocyanurate side facing down. Top Insulation Layer Insulation Fasteners (Table 3) Fastener Density/ft2 DensDeck, DensDeck Prime, SECUROCK Gypsum-Fiber Roof Board Minimum ¼” thick N/A N/A Note: Apply top layer of insulation in a full mopping of any approved mopping asphalt within the EVT range and at a rate of 20-40 lbs/100 ft2. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Insulation listed as Base Layer only shall be used only as base layers with a second layer of approved top layer insulation installed as the final membrane substrate. Composite insulation panels may be used as a top layer placed with the polyisocyanurate side facing down. Base Sheet: One or more plies of Elastoflex SA V (1.5-mm), Elastoflex SA V PLUS, XtraFlex SBS Base SA, Elastoflex SA V FR (1.5-mm) or Elastoflex SA V PLUS FR, self-adhered. NOA No.: 17-1004.09 Expiration Date: 10/11/22 Approval Date: 10/12/17 Page 11 of 34 Membrane: One ply of Polyfresko G SBS SA, Polyfresko G SBS SA FR, Polyfresko G APP SA, Polyfresko G APP SA FR, Elastoflex SA P, Elastoflex SA P FR, XtraFlex SBS G SA, Polyflex SA P, PolyKool, XtraFlex Kool APP SA, Polyflex SA P FR or XtraFlex APP G SA, self- adhered. Or One ply of Polyflex G, torch-applied. Surfacing: (Optional) Install one of the approved surfacing products listed in Table 4 to obtain desired coating or required fire classification. Maximum Design Pressure: -52.5 psf; (See general limitation #7.) NOA No.: 17-1004.09 Expiration Date: 10/11/22 Approval Date: 10/12/17 Page 12 of 34 Membrane Type: SBS/APP Deck Type 1I: Wood, Insulated Deck Description: 19/32" or greater plywood or wood plank, fastened at 24” spans with #8 wood screws at 6” o.c . System Type A(2): All insulation layers are adhered to a mechanically attached anchor sheet. Membrane is subsequently adhered to insulation. All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are not approved and shall not be installed unless said accessories demonstrate compliance with prescriptive Florida Building Code requirements and are field fabricated utilizing the approved membranes listed in Table 1. Anchor Sheet: One ply of Elastobase, XtraFlex SBS Glass Base, Elastobase P, Polyglass G2 Base, Polyflex, XtraFlex APP S or Polybond fastened to the deck as described below: Fastening: Attach base sheet using OMG #14 Roofgrip fasteners and Flat Bottom Metal Plates spaced 12” o.c. in a 4” lap and 12” o.c. in two equally spaced staggered rows in the center of the sheet. One or more of the following Base Insulation Layer (Optional) Insulation Fasteners (Table 3) Fastener Density/ft2 Any approved Polyisocyanurate listed in Table 2 Minimum 1” thick N/A N/A Top Insulation Layer Insulation Fasteners (Table 3) Fastener Density/ft2 DensDeck, DensDeck Prime, SECUROCK Gypsum-Fiber Roof Board Minimum ¼” thick N/A N/A Note: All insulation shall be adhered to the anchor sheet in full mopping of approved hot asphalt within the EVT range and at a rate of 20-40 lbs/100 ft2. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Insulation listed as base layer only shall be used only as base layers with a second layer of approved top layer insulation installed as the final membrane substrate. Composite insulation panels may be used as a top layer placed with the polyisocyanurate side facing down. Base Sheet: One or more plies of Elastoflex SA V (1.5-mm), Elastoflex SA V PLUS, XtraFlex SBS Base SA, Elastoflex SA V FR (1.5-mm) or Elastoflex SA V PLUS FR, self-adhered. Membrane: One ply of Polyfresko G SBS SA, Polyfresko G SBS SA FR, Polyfresko G APP SA, Polyfresko G APP SA FR, Elastoflex SA P, Elastoflex SA P FR, XtraFlex SBS G SA, Polyflex SA P, PolyKool, XtraFlex Kool APP S SA, Polyflex SA P FR or XtraFlex APP G SA, self- adhered. Or One ply of Polyflex G, torch-applied. NOA No.: 17-1004.09 Expiration Date: 10/11/22 Approval Date: 10/12/17 Page 13 of 34 Surfacing: (Optional) Install one of the approved surfacing products listed in Table 4 to obtain desired coating or required fire classification. Maximum Design Pressure: -60 psf; (See general limitation #7.) NOA No.: 17-1004.09 Expiration Date: 10/11/22 Approval Date: 10/12/17 Page 14 of 34 Membrane Type: SBS/APP Deck Type 1I: Wood, Insulated Deck Description: 19/32" or greater plywood or wood plank, fastened at 24” spans with 8d common nails at 4” o.c. or #8 wood screws at 6” o.c . System Type A(3): All insulation layers are adhered to a mechanically attached anchor sheet. Membrane is subsequently adhered to insulation. All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are not approved and shall not be installed unless said accessories demonstrate compliance with prescriptive Florida Building Code requirements and are field fabricated utilizing the approved membranes listed in Table 1. Anchor Sheet: One ply of Polyglass G2 Base fastened to the deck as described below: Fastening: Attach base sheet using 11 ga. Annular ring shank and 1-5/8” diameter tin caps spaced 8” o.c. in a 4” lap and 8” o.c. in three equally spaced staggered rows in the center of the sheet. One of more of the following: Base Insulation Layer (Optional) Insulation Fasteners (Table 3) Fastener Density/ft2 Any approved Polyisocyanurate listed in Table 2 Minimum 1” thick N/A N/A Note: All insulation shall be adhered to the anchor sheet in full mopping of approved hot asphalt within the EVT range and at a rate of 20-40 lbs/100 ft2. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Insulation listed as base layer only shall be used only as base layers with a second layer of approved top layer insulation installed as the final membrane substrate. Composite insulation panels may be used as a top layer placed with the polyisocyanurate side facing down. Top Insulation Layer Insulation Fasteners (Table 3) Fastener Density/ft2 Dens Deck, Dens Deck Prime, SECUROCK Gypsum-Fiber Roof Board Minimum ¼” thick N/A N/A Note: Apply top layer of insulation in a full mopping of any approved mopping asphalt within the EVT range and at a rate of 20-40 lbs/100 ft2. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Insulation listed as Base Layer only shall be used only as base layers with a second layer of approved top layer insulation installed as the final membrane substrate. Composite insulation panels may be used as a top layer placed with the polyisocyanurate side facing down. Base Sheet: One or more plies of Elastoflex SA V (1.5-mm), Elastoflex SA V PLUS, XtraFlex SBS Base SA, Elastoflex SA V FR (1.5-mm) or Elastoflex SA V PLUS FR, self-adhered. NOA No.: 17-1004.09 Expiration Date: 10/11/22 Approval Date: 10/12/17 Page 15 of 34 Membrane: One ply of Polyfresko G SBS SA, Polyfresko G SBS SA FR, Polyfresko G APP SA, Polyfresko G APP SA FR, Elastoflex SA P, Elastoflex SA P FR, XtraFlex SBS G SA, Polyflex SA P, PolyKool, XtraFlex Kool APP S SA, Polyflex SA P FR or XtraFlex APP G SA, self- adhered. Or One ply of Polyflex G, torch-applied. Surfacing: (Optional) Install one of the approved surfacing products listed in Table 4 to obtain desired coating or required fire classification. Maximum Design Pressure: -52.5 psf; (See general limitation #7.) NOA No.: 17-1004.09 Expiration Date: 10/11/22 Approval Date: 10/12/17 Page 16 of 34 Membrane Type: SBS/APP Deck Type 1I: Wood, Insulated Deck Description: 19/32" or greater plywood or wood plank fastened at 24” spans with #8 wood screws at 6” o.c. System Type A(4): All insulation layers are adhered to a mechanically attached anchor sheet. Membrane is subsequently adhered to insulation. All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are not approved and shall not be installed unless said accessories demonstrate compliance with prescriptive Florida Building Code requirements and are field fabricated utilizing the approved membranes listed in Table 1. Anchor Sheet: One ply of Elastobase, XtraFlex SBS Glass Base or Elastobase P fastened as below: Fastening: 12 ga. Annular ring shank nails and 1-5/8” tin-caps attached 6” o.c. in 4” lap and 6” o.c. in four equally spaced staggered rows. Base Insulation Layer Insulation Fasteners (Table 3) Fastener Density/ft2 ACFoam-II, Polytherm, ACFoam-III, H-Shield, Polytherm-H, H-Shield CG, Multi-Max FA-3, ENRGY 3 Minimum 1” thick N/A N/A Note: All insulation shall be adhered to the anchor sheet with Millennium One-Step Foamable Adhesive applied over rows of tin-caps in continuous rows 7” o.c. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Insulation listed as base layer only shall be used only as base layers with a second layer of approved top layer insulation installed as the final membrane substrate. Composite insulation panels may be used as a top layer placed with the polyisocyanurate side facing down. Base Sheet: One or more plies of Elastoflex SA V (1.5-mm), Elastoflex SA V PLUS, XtraFlex SBS Base SA, Elastoflex SA V FR (1.5-mm) or Elastoflex SA V PLUS FR, self-adhered. Membrane: One ply of Polyfresko G SBS SA, Polyfresko G SBS SA FR, Polyfresko G APP SA, Polyfresko G APP SA FR, Elastoflex SA P, Elastoflex SA P FR, XtraFlex SBS G SA, Polyflex SA P, PolyKool, XtraFlex Kool APP S SA, Polyflex SA P FR or XtraFlex APP G SA, self- adhered. Or One ply of Polyflex G, torch-applied. Surfacing: (Optional) Install one of the approved surfacing products listed in Table 4 to obtain desired coating or required fire classification. Maximum Design Pressure: -60 psf; (See general limitation #7.) NOA No.: 17-1004.09 Expiration Date: 10/11/22 Approval Date: 10/12/17 Page 17 of 34 Membrane Type: SBS/APP Deck Type 1I: Wood, Insulated Deck Description: 19/32" or greater plywood or wood plank, fastened at 24” spans with 8d common nails or wood screws at 4” o.c. System Type C(1): All layers of insulation are mechanically attached to roof deck. Membranes subsequently adhered to insulation. All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are not approved and shall not be installed unless said accessories demonstrate compliance with prescriptive Florida Building Code requirements and are field fabricated utilizing the approved membranes listed in Table 1. One or more of the following Base Insulation Layer Insulation Fasteners (Table 3) Fastener Density/ft2 Any approved Polyisocyanurate listed in Table 2 Minimum 1.5” thick N/A N/A Note: All layers shall be simultaneously fastened; see top layer below for fasteners and density. Insulation panels listed are minimum sizes and dimensions; if larger panels are used, the number of fasteners shall be increased maintaining the same fastener density. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Top Insulation Layer Insulation Fasteners (Table 3) Fastener Density/ft2 Approved High Density Wood Fiberboard Minimum ½” thick 1 1:1.33 ft² DensDeck Minimum ¼” thick 1 1:1.33 ft² Note: All layers of insulation shall be mechanically attached using the fastener density listed above. The insulation panels listed are minimum sizes and dimensions; if larger panels are used, the number of fasteners shall be increased maintaining the same fastener density. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Base Sheet: One or more plies of Elastoflex SA V (1.5-mm), Elastoflex SA V PLUS, XtraFlex SBS Base SA, Elastoflex SA V FR (1.5-mm) or Elastoflex SA V PLUS FR, self-adhered. Membrane: One ply of Polyfresko G SBS SA, Polyfresko G SBS SA FR, Polyfresko G APP SA, Polyfresko G APP SA FR, Elastoflex SA P, Elastoflex SA P FR, XtraFlex SBS G SA, Polyflex SA P, PolyKool, XtraFlex Kool APP S SA, Polyflex SA P FR or XtraFlex APP G SA, self- adhered. Or One ply of Polyflex G, torch-applied. Surfacing: (Optional) Install one of the approved surfacing products listed in Table 4 to obtain desired NOA No.: 17-1004.09 Expiration Date: 10/11/22 Approval Date: 10/12/17 Page 18 of 34 coating or required fire classification. Maximum Design Pressure: -67.5 psf; (See General limitation #7.) NOA No.: 17-1004.09 Expiration Date: 10/11/22 Approval Date: 10/12/17 Page 19 of 34 Membrane Type: SBS/APP Deck Type 1I: Wood, Insulated Deck Description: 19/32" or greater plywood or wood plank, fastened at 24” spans with 8d common nails at 4” o.c. System Type C(2): All layers of insulation are mechanically attached to roof deck. Membranes subsequently adhered to insulation. All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are not approved and shall not be installed unless said accessories demonstrate compliance with prescriptive Florida Building Code requirements and are field fabricated utilizing the approved membranes listed in Table 1. One or more layers of the following: Base Insulation Layer Insulation Fasteners (Table 3) Fastener Density/ft2 Any approved Polyisocyanurate listed in Table 2 Minimum 1.5” thick N/A N/A Note: All layers shall be simultaneously fastened; see top layer below for fasteners and density. Insulation panels listed are minimum sizes and dimensions; if larger panels are used, the number of fasteners shall be increased maintaining the same fastener density. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Top Insulation Layer Insulation Fasteners (Table 3) Fastener Density/ft2 Approved High Density Wood Fiberboard Minimum ½” thick 1 1:1.33 ft² DensDeck Minimum ¼” thick 1 1:1.33 ft² Note: All layers of insulation shall be mechanically attached using the fastener density listed above. The insulation panels listed are minimum sizes and dimensions; if larger panels are used, the number of fasteners shall be increased maintaining the same fastener density. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Base Sheet: One or more plies of Elastoflex SA V (1.5-mm), Elastoflex SA V PLUS, XtraFlex SBS Base SA, Elastoflex SA V FR (1.5-mm) or Elastoflex SA V PLUS FR, self-adhered. Membrane: One ply of Polyfresko G SBS SA, Polyfresko G SBS SA FR, Polyfresko G APP SA, Polyfresko G APP SA FR, Elastoflex SA P, Elastoflex SA P FR, XtraFlex SBS G SA, Polyflex SA P, PolyKool, XtraFlex Kool APP S SA, Polyflex SA P FR or XtraFlex APP G SA, self- adhered. Or One ply of Polyflex G, torch-applied. NOA No.: 17-1004.09 Expiration Date: 10/11/22 Approval Date: 10/12/17 Page 20 of 34 Surfacing: (Optional) Install one of the approved surfacing products listed in Table 4 to obtain desired coating or required fire classification. Maximum Design Pressure: -67.5 psf; (See General limitation #7.) NOA No.: 17-1004.09 Expiration Date: 10/11/22 Approval Date: 10/12/17 Page 21 of 34 Membrane Type: SBS/APP Deck Type 1I: Wood, Insulated Deck Description: 19/32" or greater plywood or wood plank, fastened at 24” spans with wood screws at 6” o.c. System Type C(3): All layers of insulation are mechanically attached to roof deck. Membranes subsequently adhered to insulation. All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are not approved and shall not be installed unless said accessories demonstrate compliance with prescriptive Florida Building Code requirements and are field fabricated utilizing the approved membranes listed in Table 1. One or more of the following: Insulation Layer Insulation Fasteners (Table 3) Fastener Density/ft2 ENRGY 3, H-Shield, Polytherm-H, ACFoam-II, Polytherm Minimum 1.5” thick 1, 5 or 7 1:1.33 ft² Note: All layers of insulation shall be mechanically attached using the fastener density listed above. The insulation panels listed are minimum sizes and dimensions; if larger panels are used, the number of fasteners shall be increased maintaining the same fastener density. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Base Sheet: One or more plies of Elastoflex SA V (1.5-mm), Elastoflex SA V PLUS, XtraFlex SBS Base SA, Elastoflex SA V FR (1.5-mm) or Elastoflex SA V PLUS FR, self-adhered. Membrane: One ply of Polyfresko G SBS SA, Polyfresko G SBS SA FR, Polyfresko G APP SA, Polyfresko G APP SA FR, Elastoflex SA P, Elastoflex SA P FR, XtraFlex SBS G SA, Polyflex SA P, PolyKool, XtraFlex Kool APP S SA, Polyflex SA P FR or XtraFlex APP G SA, self- adhered. Or One ply of Polyflex G, torch-applied. Surfacing: (Optional) Install one of the approved surfacing products listed in Table 4 to obtain desired coating or required fire classification. Maximum Design Pressure: -82.5 psf; (See General limitation #7.) NOA No.: 17-1004.09 Expiration Date: 10/11/22 Approval Date: 10/12/17 Page 22 of 34 Membrane Type: SBS/APP Deck Type 1I: Wood, Insulated Deck Description: 19/32" or greater plywood or wood plank, fastened at 24” spans with #8 wood screws at 6” o.c. System Type D(1): All insulation is loosed laid with preliminary attachment to deck. Base sheet is subsequently mechanically fastened through insulation to the roof deck. Membranes subsequently adhered. All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are not approved and shall not be installed unless said accessories demonstrate compliance with prescriptive Florida Building Code requirements and are field fabricated utilizing the approved membranes listed in Table 1. One or more layers of the following: Base Insulation Layer Insulation Fasteners (Table 3) Fastener Density/ft2 Any approved Polyisocyanurate listed in Table 2 Minimum 1” thick N/A N/A Top Insulation Layer (Optional) Insulation Fasteners (Table 3) Fastener Density/ft2 Fesco Board Minimum ¾” thick N/A N/A Approved High Density Wood Fiberboard Minimum ½” thick N/A N/A DensDeck, DensDeck Prime, SECUROCK Gypsum-Fiber Roof Board Minimum ¼” thick N/A N/A Note: All insulation shall have preliminary attachment, prior to the installation of the roofing membrane at a minimum application rate of two fasteners per board for insulation boards having no dimension greater than 4 ft., and four fasteners for any insulation board having no dimension greater than 8 ft. Base Sheet: One or more plies of Elastobase, XtraFlex SBS Glass Base, Elastobase P or Polyanchor fastened to the deck as described below: Fastening: Attach base sheet using OMG #14 Roofgrip fasteners and Flat Bottom Metal Plates, Dekfast 14 with Dekfast Galvalume Steel Hex Plates, Polygrip Fasteners #14 with Polygrip Hex Plates or Trufast #14 HD Fasteners with Trufast 3” Metal Insulation Plates spaced 12” o.c. in a 4” lap and 12” o.c. in two equally spaced staggered rows in the center of the sheet. Ply Sheet: One or more plies of Elastoflex SA V (1.5-mm), Elastoflex SA V PLUS, XtraFlex SBS Base SA, Elastoflex SA V FR (1.5-mm) or Elastoflex SA V PLUS FR, self-adhered. NOA No.: 17-1004.09 Expiration Date: 10/11/22 Approval Date: 10/12/17 Page 23 of 34 Membrane: One ply of Polyfresko G SBS SA, Polyfresko G SBS SA FR, Polyfresko G APP SA, Polyfresko G APP SA FR, Elastoflex SA P, Elastoflex SA P FR, XtraFlex SBS G SA, Polyflex SA P, PolyKool, XtraFlex Kool APP S SA, Polyflex SA P FR or XtraFlex APP G SA, self- adhered. Or One ply of Polyflex G, torch-applied. Surfacing: (Optional) Install one of the approved surfacing products listed in Table 4 to obtain desired coating or required fire classification. Maximum Design Pressure: -52.5 psf; (See General limitation #7.) NOA No.: 17-1004.09 Expiration Date: 10/11/22 Approval Date: 10/12/17 Page 24 of 34 Membrane Type: SBS/APP Deck Type 1I: Wood, Insulated Deck Description: 19/32" or greater plywood or wood plank, fastened at 24” spans with #8 wood screws at 6” o.c. System Type D(2): All insulation is loosed laid with preliminary attachment to deck. Base sheet is subsequently mechanically fastened through insulation to the roof deck. Membranes subsequently adhered. All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are not approved and shall not be installed unless said accessories demonstrate compliance with prescriptive Florida Building Code requirements and are field fabricated utilizing the approved membranes listed in Table 1. One or more layers of the following: Base Insulation Layer Insulation Fasteners (Table 3) Fastener Density/ft2 Any approved Polyisocyanurate listed in Table 2 Minimum 1” thick N/A N/A Top Insulation Layer (Optional) Insulation Fasteners (Table 3) Fastener Density/ft2 Fesco Board Minimum ¾” thick N/A N/A Approved High Density Wood Fiberboard Minimum ½” thick N/A N/A DensDeck, DensDeck Prime, SECUROCK Gypsum-Fiber Roof Board Minimum ¼” thick N/A N/A Note: All insulation shall have preliminary attachment, prior to the installation of the roofing membrane at a minimum application rate of two fasteners per board for insulation boards having no dimension greater than 4 ft., and four fasteners for any insulation board having no dimension greater than 8 ft. Base Sheet: One or more plies of Elastobase, XtraFlex SBS Glass Base, Elastobase P or Polyanchor fastened to the deck as described below: Fastening: Attach base sheet using OMG #14 Roofgrip fasteners and Flat Bottom Metal Plates spaced 12” o.c. in a 4” lap and 12” o.c. in two equally spaced staggered rows in the center of the sheet. Ply Sheet: One or more plies of Elastoflex SA V (1.5-mm), Elastoflex SA V PLUS, XtraFlex SBS Base SA, Elastoflex SA V FR (1.5-mm) or Elastoflex SA V PLUS FR, self-adhered. NOA No.: 17-1004.09 Expiration Date: 10/11/22 Approval Date: 10/12/17 Page 25 of 34 Membrane: One ply of Polyfresko G SBS SA, Polyfresko G SBS SA FR, Polyfresko G APP SA, Polyfresko G APP SA FR, Elastoflex SA P, Elastoflex SA P FR, XtraFlex SBS G SA, Polyflex SA P, PolyKool, XtraFlex Kool APP S SA, Polyflex SA P FR or XtraFlex APP G SA, self- adhered. Or One ply of Polyflex G, torch-applied. Surfacing: (Optional) Install one of the approved surfacing products listed in Table 4 to obtain desired coating or required fire classification. Maximum Design Pressure: -60 psf; (See General limitation #7.) NOA No.: 17-1004.09 Expiration Date: 10/11/22 Approval Date: 10/12/17 Page 26 of 34 Membrane Type: SBS/APP Deck Type 1: Wood, Non-Insulated Deck Description: 19/32" or greater plywood or wood plank, fastened at 24” spans with 8d common nails at 4” o.c. or #8 wood screws at 6” o.c. System Type E(1): Base sheet is mechanically attached to roof deck. All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are not approved and shall not be installed unless said accessories demonstrate compliance with prescriptive Florida Building Code requirements and are field fabricated utilizing the approved membranes listed in Table 1. Base Sheet: One ply of Elastobase, XtraFlex SBS Glass Base, Elastobase P or Polyanchor fastened to the deck as described below: Fastening: Attach base sheet using 11 ga. annular ring shank nails and 1-5/8” diameter tin caps spaced 8” o.c. in a 4” lap and 8” o.c. in three equally spaced staggered rows in the center of the sheet. Ply Sheet: One or more plies of Elastoflex SA V (1.5-mm), Elastoflex SA V PLUS, XtraFlex SBS Base SA, Elastoflex SA V FR (1.5-mm) or Elastoflex SA V PLUS FR, self-adhered. Membrane: One ply of Polyfresko G SBS SA, Polyfresko G SBS SA FR, Polyfresko G APP SA, Polyfresko G APP SA FR, Elastoflex SA P, Elastoflex SA P FR, XtraFlex SBS G SA, Polyflex SA P, PolyKool, XtraFlex Kool APP S SA, Polyflex SA P FR or XtraFlex APP G SA, self- adhered. Or One ply of Polyflex G, torch-applied. Surfacing: (Optional) Install one of the approved surfacing products listed in Table 4 to obtain desired coating or required fire classification. Maximum Design Pressure: -52.5 psf; (See General limitation #7.). NOA No.: 17-1004.09 Expiration Date: 10/11/22 Approval Date: 10/12/17 Page 27 of 34 Membrane Type: SBS/APP Deck Type 1: Wood, Non-Insulated Deck Description: 19/32" or greater plywood or wood plank, fastened at 24” spans with #8 wood screws at 6” o.c. System Type E(2): Base sheet is mechanically attached to roof deck. All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are not approved and shall not be installed unless said accessories demonstrate compliance with prescriptive Florida Building Code requirements and are field fabricated utilizing the approved membranes listed in Table 1. Base Sheet: One ply of Elastobase, XtraFlex SBS Glass Base, Elastobase P or Polyanchor fastened to the deck as described below: Fastening #: Attach base sheet using OMG #14 Roofgrip fasteners and Flat Bottom Metal Plates, Dekfast #14 with Dekfast Galvalume Steel Hex Plates, Polygrip Fasteners #14 with Polygrip Hex Plates or Trufast #14 HD Fasteners with Trufast 3” Metal Insulation Plates spaced 12” o.c. in a 4” lap and 12” o.c. in two equally spaced staggered rows in the center of the sheet. Ply Sheet: One or more plies of Elastoflex SA V (1.5-mm), Elastoflex SA V PLUS, XtraFlex SBS Base SA, Elastoflex SA V FR (1.5-mm) or Elastoflex SA V PLUS FR, self-adhered. Membrane: One ply of Polyfresko G SBS SA, Polyfresko G SBS SA FR, Polyfresko G APP SA, Polyfresko G APP SA FR, Elastoflex SA P, Elastoflex SA P FR, XtraFlex SBS G SA, Polyflex SA P, PolyKool, XtraFlex Kool APP S SA, Polyflex SA P FR or XtraFlex APP G SA, self- adhered. Or One ply of Polyflex G, torch-applied. Surfacing: (Optional) Install one of the approved surfacing products listed in Table 4 to obtain desired coating or required fire classification. Maximum Design Pressure: -60 psf; (See General limitation #7.). NOA No.: 17-1004.09 Expiration Date: 10/11/22 Approval Date: 10/12/17 Page 28 of 34 Membrane Type: SBS/APP Deck Type 1: Wood, Non-Insulated Deck Description: 19/32" or greater plywood or wood plank, fastened at 24” spans with 8d ring shank nails at 6” o.c. at edges and intermediate supports. System Type E(3): Base sheet is mechanically attached to roof deck. Membranes subsequently adhered to insulation. All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are not approved and shall not be installed unless said accessories demonstrate compliance with prescriptive Florida Building Code requirements and are field fabricated utilizing the approved membranes listed in Table 1. Base Sheet: One ply of Polyglass APP Base, Elastobase (Poly/Sand) sheet fastened to the deck as described below: Fastening: Attach base sheet using 11 ga. annular grooved shank and 1” diameter caps spaced 6” o.c. in a 3” lap and 6” o.c. in four equally spaced staggered center rows. Membrane: One ply of Elastoflex SA P, Elastoflex SA P FR, XtraFlex SBS G SA, Polyfresko G SBS SA, Polyfresko G SBS SA FR, Polyflex SA P, Polyflex SA P FR, XtraFlex APP G SA, Polyfresko G APP SA, Polyfresko G APP SA FR, PolyKool or XtraFlex Kool APP S SA self-adhered. Surfacing: (Optional) Install one of the approved surfacing products listed in Table 4 to obtain desired coating or required fire classification. Maximum Design Pressure: -52.5 psf; (See General Limitation #7) NOA No.: 17-1004.09 Expiration Date: 10/11/22 Approval Date: 10/12/17 Page 29 of 34 Membrane Type: SBS/APP Deck Type 1: Wood, Non-Insulated Deck Description: 19/32" or greater plywood or wood plank, fastened at 24” spans with 8d common nails at 4” o.c. or #8 wood screws at 6” o.c System Type E(4): Base sheet is mechanically attached to roof deck. Membranes subsequently adhered to insulation. All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are not approved and shall not be installed unless said accessories demonstrate compliance with prescriptive Florida Building Code requirements and are field fabricated utilizing the approved membranes listed in Table 1. Base Sheet: One ply of Elastobase, XtraFlex SBS Glass Base, Elastobase P or Polyanchor fastened to the deck as described below: Fastening: Attach base sheet using OMG #14 Roofgrip fasteners and Flat Bottom Metal Plates spaced 12” o.c. in a 4” lap and 12” o.c. in two equally spaced staggered rows in the center of the sheet. Ply Sheet: One or more plies of Elastoflex SA V (1.5-mm), Elastoflex SA V PLUS, XtraFlex SBS Base SA, Elastoflex SA V FR (1.5-mm) or Elastoflex SA V PLUS FR, self-adhered. Membrane: One ply of Polyfresko G SBS SA, Polyfresko G SBS SA FR, Polyfresko G APP SA, Polyfresko G APP SA FR, Elastoflex SA P, Elastoflex SA P FR, XtraFlex SBS G SA, Polyflex SA P, PolyKool, XtraFlex Kool APP S SA, Polyflex SA P FR or XtraFlex APP G SA, self-adhered. Or One ply of Polyflex G, torch-applied Surfacing: (Optional) Install one of the approved surfacing products listed in Table 4 to obtain desired coating or required fire classification. Maximum Design Pressure: -52.5 psf; (See General Limitation #7) NOA No.: 17-1004.09 Expiration Date: 10/11/22 Approval Date: 10/12/17 Page 30 of 34 Membrane Type: SBS/APP Deck Type 1: Wood, Non-Insulated Deck Description: 19/32" or greater plywood or wood plank, fastened at 24” spans with 8d common nails at 4” o.c. or #8 wood screws at 6” o.c . System Type E(5): Base sheet is mechanically attached to roof deck. Membranes subsequently adhered to insulation. All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are not approved and shall not be installed unless said accessories demonstrate compliance with prescriptive Florida Building Code requirements and are field fabricated utilizing the approved membranes listed in Table 1. Base Sheet: One ply of Elastobase, XtraFlex SBS Glass Base or Elastobase P fastened to the deck as described below: Fastening: Attach base sheet using 11 ga. annular ring shank nails and 1-5/8” diameter tin caps spaced 8” o.c. in a 4” lap and 8” o.c. in three equally spaced staggered rows in the center of the sheet. Ply Sheet: One or more plies of Elastoflex SA V (1.5-mm), Elastoflex SA V PLUS, XtraFlex SBS Base SA, Elastoflex SA V FR (1.5-mm) or Elastoflex SA V PLUS FR, self-adhered. Membrane: One ply of Polyfresko G SBS SA, Polyfresko G SBS SA FR, Polyfresko G APP SA, Polyfresko G APP SA FR, Elastoflex SA P, Elastoflex SA P FR, XtraFlex SBS G SA, Polyflex SA P, PolyKool, XtraFlex Kool APP S SA, Polyflex SA P FR or XtraFlex APP G SA, self-adhered. Or One ply of Polyflex G, torch-applied Surfacing: (Optional) Install one of the approved surfacing products listed in Table 4 to obtain desired coating or required fire classification. Maximum Design Pressure: -52.5 psf; (See General Limitation #7) NOA No.: 17-1004.09 Expiration Date: 10/11/22 Approval Date: 10/12/17 Page 31 of 34 Membrane Type: SBS/APP Deck Type 1: Wood, Non-Insulated Deck Description: 19/32" or greater plywood or wood plank, fastened to supports spaced 24” o.c. and to blocking members spaced 48” o.c. with TruFast TP #10x2-7/8” screws spaced 6” o.c. System Type E(6): Base sheet is mechanically attached to roof deck. Membranes subsequently adhered to insulation. All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are not approved and shall not be installed unless said accessories demonstrate compliance with prescriptive Florida Building Code requirements and are field fabricated utilizing the approved membranes listed in Table 1. Base Sheet: One ply of Elastobase, XtraFlex SBS Glass Base or Elastobase P fastened to the deck as described below: Fastening: Attach base sheet using 11 ga. annular ring shank nails and 1-5/8” diameter tin caps spaced 4” o.c. in a 4” lap and 4” o.c. in three equally spaced staggered rows in the center of the sheet. Ply Sheet: One or more plies of Elastoflex SA V (1.5-mm), Elastoflex SA V PLUS, XtraFlex SBS Base SA, Elastoflex SA V FR (1.5-mm) or Elastoflex SA V PLUS FR, self-adhered. Membrane: One ply of Polyfresko G SBS SA, Polyfresko G SBS SA FR, Elastoflex SA P, Elastoflex SA P FR or XtraFlex SBS G SA, self-adhered. Or One ply of Polyflex G, torch-applied Surfacing: (Optional) Install one of the approved surfacing products listed in Table 4 to obtain desired coating or required fire classification. Maximum Design Pressure: -97.5 psf; (See General Limitation #7) NOA No.: 17-1004.09 Expiration Date: 10/11/22 Approval Date: 10/12/17 Page 32 of 34 Membrane Type: SBS/APP Deck Type 1: Wood, Non-Insulated Deck Description: 19/32" or greater plywood or wood plank, fastened to supports spaced 24” o.c. and to blocking members spaced 48” o.c. with #10x3” wood screws spaced 6” o.c. System Type E(7): Base sheet is mechanically attached to roof deck. Membranes subsequently adhered to insulation. All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are not approved and shall not be installed unless said accessories demonstrate compliance with prescriptive Florida Building Code requirements and are field fabricated utilizing the approved membranes listed in Table 1. Base Sheet: One ply of Elastobase, XtraFlex SBS Glass Base or Elastobase P fastened to the deck as described below: Fastening: Attach base sheet using 12 ga. ring shank nails and tin caps spaced 4” o.c. in a 4” lap and 4” o.c. in four equally spaced staggered rows in the center of the sheet. Ply Sheet: One or more plies of Elastoflex SA V (1.5-mm), Elastoflex SA V PLUS, XtraFlex SBS Base SA, Elastoflex SA V FR (1.5-mm) or Elastoflex SA V PLUS FR, self-adhered. Membrane: One ply of Polyfresko G SBS SA, Polyfresko G SBS SA FR, Elastoflex SA P, Elastoflex SA P FR or XtraFlex SBS G SA, self-adhered. Or One ply of Polyflex G, torch-applied Surfacing: (Optional) Install one of the approved surfacing products listed in Table 4 to obtain desired coating or required fire classification. Maximum Design Pressure: -112.5 psf; With Elastoflex SA V PLUS, XtraFlex SBS Base SA or Elastoflex SA V PLUS FR (See General limitation #7.) -97.5 psf; With Elastoflex SA V(1.5-mm) or Elastoflex SA V FR(1.5-mm) (See General limitation #7.) NOA No.: 17-1004.09 Expiration Date: 10/11/22 Approval Date: 10/12/17 Page 33 of 34 Membrane Type: SBS/APP Deck Type 1: Wood, Non-Insulated Deck Description: 19/32" or greater plywood or wood plank, fastened to supports spaced 24” o.c. with #8x3” wood screws spaced 6” o.c. System Type E(8): Base sheet is mechanically attached to roof deck. Membranes subsequently adhered to insulation. All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are not approved and shall not be installed unless said accessories demonstrate compliance with prescriptive Florida Building Code requirements and are field fabricated utilizing the approved membranes listed in Table 1. Base Sheet: One ply of Elastobase, XtraFlex SBS Glass Base or Elastobase P fastened to the deck as described below: Fastening: 12 ga. annular ring shanked nails and 1-5/8” tin-caps 6” o.c. in 4” lap and 6” o.c. in four equally spaced staggered rows. Tin-caps are primed with PG100 Asphalt Primer or XtraFlex 10 Asphalt Primer. Ply Sheet: One or more plies of Elastoflex SA V (1.5-mm), Elastoflex SA V PLUS, XtraFlex SBS Base SA, Elastoflex SA V FR (1.5-mm) or Elastoflex SA V PLUS FR, self-adhered. Membrane: One ply of Polyfresko G SBS SA, Polyfresko G SBS SA FR, Polyfresko G APP SA, Polyfresko G APP SA FR, Elastoflex SA P, Elastoflex SA P FR, XtraFlex SBS G SA, Polyflex SA P, PolyKool, XtraFlex Kool APP S SA, Polyflex SA P FR or XtraFlex APP G SA, self-adhered. Or One ply of Polyflex G, torch-applied Surfacing: (Optional) Install one of the approved surfacing products listed in Table 4 to obtain desired coating or required fire classification. Maximum Design Pressure: -112.5 psf; With Elastoflex SA V PLUS, XtraFlex SBS Base SA or Elastoflex SA V PLUS FR (See General limitation #7.) -97.5 psf; With Elastoflex SA V(1.5-mm) or Elastoflex SA V FR(1.5-mm) (See General limitation #7.) NOA No.: 17-1004.09 Expiration Date: 10/11/22 Approval Date: 10/12/17 Page 34 of 34 WOOD DECK SYSTEM LIMITATIONS: 1. A slip sheet is required with Ply 4 and Ply 6 when used as a mechanically fastened base or anchor sheet. GENERAL LIMITATIONS: 1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with Product Control Approval guidelines. All other layers shall be adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq., or mechanically attached using the fastening pattern of the top layer 3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved asphalt, panel size shall be 4' x 4' maximum. 4. An overlay and/or recovery board insulation panel is required on all applications over closed cell foam insulations when the base sheet is fully mopped. If no recovery board is used the base sheet shall be applied using spot mopping with approved asphalt, 12" diameter circles, 24" o.c.; or strip mopped 8" ribbons in three rows, one at each side lap and one down the center of the sheet allowing a continuous area of ventilation. Encircling of the strips is not acceptable. A 6" break shall be placed every 12' in each ribbon to allow cross ventilation. Asphalt application of either system shall be at a minimum rate of 12 lbs./sq. Note: Spot attached systems shall be limited to a maximum design pressure of -45 psf. 5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force (F') value of 275 lbf., as tested in compliance with Testing Application Standard TAS 105. If the fastener value, as field-tested, are below 275 lbf. insulation attachment shall not be acceptable. 6. Fastener spacing for mechanical attachment of anchor/base sheet or membrane attachment is based on a minimum fastener resistance value in conjunction with the maximum design value listed within a specific system. Should the fastener resistance be less than that required, as determined by the Building Official, a revised fastener spacing, prepared, signed and sealed by a Florida registered Professional Engineer, Registered Architect, or Registered Roof Consultant may be submitted. Said revised fastener spacing shall utilize the withdrawal resistance value taken from Testing Application Standards TAS 105 and calculations in compliance with Roofing Application Standard RAS 117. 7. Perimeter and corner areas shall comply with the enhanced uplift pressure requirements of these areas. Fastener densities shall be increased for both insulation and base sheet as calculated in compliance with Roofing Application Standard RAS 117. Calculations prepared, signed and sealed by a Florida registered Professional Engineer, Registered Architect, or Registered Roof Consultant (When this limitation is specifically referred within this NOA, General Limitation #9 will not be applicable.) 8. All attachment and sizing of perimeter nailers, metal profile, and/or flashing termination designs shall conform to Roofing Application Standard RAS 111 and applicable wind load requirements. 9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e. field, perimeters, and corners). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at enhanced pressure zones (i.e. perimeters, extended corners and corners). (When this limitation is specifically referred within this NOA, General Limitation #7 will not be applicable.) 10. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61G20-3 of the Florida Administrative Code. END OF THIS ACCEPTANCE DESCRIPTION ACCOUNT QTY PAID PermitTRAK $1,052.17 ROOF22-0035 Address: 465 BEACH AVE APN: 170159 0000 $1,052.17 BLDG SUBSEQUENT PLAN REVIEW FEES $50.00 BLDG 2ND PLAN REVIEW FEE 455-0000-322-1006 0 $50.00 BUILDING $651.00 BUILDING PERMIT 455-0000-322-1000 0 $651.00 BUILDING PLAN REVIEW $325.50 BUILDING PLAN CHECK 455-0000-322-1001 0 $325.50 STATE SURCHARGES $25.67 STATE DBPR SURCHARGE 455-0000-208-0700 0 $15.40 STATE DCA SURCHARGE 455-0000-208-0600 0 $10.27 TOTAL FEES PAID BY RECEIPT: R20048 $1,052.17 Printed: Monday, July 11, 2022 8:38 AM Date Paid: Monday, July 11, 2022 Paid By: THOMPSON ROOFING & RECONSTRUCTION Pay Method: CREDIT CARD 666148279 1 of 1 Cashier: TG Cash Register Receipt City of Atlantic Beach Receipt Number R20048 ~+; CENTRALSQUARE