Loading...
132 SEMINOLE RD RERF22-0041 COAB Permit Form with ConditionsFinal Plumbing Final Electrical Final HVAC CC Final Final Building* Swimming Pool Steel Swimming Pool Safety Electrical Grounding & Bonding Swimming Pool Final (Bldg) Swimming Pool Final (PW) Formed Columns/ Beams* Masonry Cell Fill Structural Steel* OTHER: OTHER: OTHER: OTHER: OTHER: Power Pole Silt Fence Piers/ Stem Walls Underground Plumbing Underground Electric Foundation/ Footing Slab** Retaining Wall Footing Driveway Sewer (Building Dept) Sewer Tap (Utilities Dept) Rough Electric* Rough Plumbing/ Top Out* Rough Mechanical* House Wrap Wall Sheathing Roof Sheathing Tie-down Framing Connections Rough Framing Roofing In Progress Window/Door In-Progress Insulation Ceiling Insulation Wall Exterior Lath Stucco Scratch Coat Exterior Siding In-Progress Brick Flashing & Ties Early Power Gas Rough Gas Final* * When all rough electric, plumbing, mechanical are complete but before any work is covered up. * When all gas piping is complete and wallboard is installed but before gas is attached to any appliance. All outlets must be capped and pipe pressurized at a minimum of 15 lbs. * For new living space: When all construction work including electrical, plumbing, mechanical, exterior finish, grading, required paving and landscaping is complete and the building is ready for occupancy, but before being occupied Additional inspections may apply to your project if your project contains these elements: INSPECTIONS REQUIRED FOR BUILDING PERMITS To verify compliance with building codes, inspections of the work authorized are required at various points of the construction. The following inspections are typically required for residential projects: Date: Initial: Date: Initial: _____________________________________________________ Permit Type ____________________________________________________ Permit No. __________________________________________________________ Job Address ____________________________________________________ Contractor POST THIS CARD WITH PERMITS AND PERMIT DOCUMENTATION IN FRONT OF BUILDING Construction Hours per City Code: 7am—7pm Weekdays; 9am—7pm Weekends Building Department Public Works/Utilities Fire Department Phone: 904-247-5826 Phone: 904-247-5834 Phone: 904-630-4789 Fax: 904-247-5845 Fax: 904-247-5843 Fax: 904-630-4203 * When forms and reinforcing steel, anchor bolts, sleeves and inserts, and all electrical, plumbing and mechanical work is in place, but before concrete is poured. * When all structural steel members are in place and all connections are complete, but before such work is covered or concealed. ** FORM BOARD ELEVATION CERTIFICATE MUST BE ON-SITE FOR SLAB INSPECTION MODIFIED BIT ROOF ROOF22-0041 132 SEMINOLE RD JORDAN ROOFING LLC OWNER:ADDRESS:CITY:STATE:ZIP: SMOAK BARBARA J 132 SEMINOLE RD ATLANTIC BEACH FL 32233-4141 COMPANY:ADDRESS:CITY:STATE:ZIP: Jordan Roofing LLC 1278 McGirts Creek Dr E Jacksonville FL 32221 TYPE OF CONSTRUCTION: REAL ESTATE NUMBER:ZONING:BUILDING USE GROUP:SUBDIVISION: 170598 0000 SALTAIR SEC 01 JOB ADDRESS:PERMIT TYPE:DESCRIPTION: VALUE OF WORK: 132 SEMINOLE RD ROOF NON SHINGLE MODIFIED BIT. ROOF $10800.00 FEES DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT BLDG 2ND PLAN REVIEW FEE 455-0000-322-1006 0 $50.00 BUILDING PERMIT 455-0000-322-1000 0 $105.00 BUILDING PLAN CHECK 455-0000-322-1001 0 $52.50 STATE DBPR SURCHARGE 455-0000-208-0700 0 $3.11 STATE DCA SURCHARGE 455-0000-208-0600 0 $2.08 TOTAL: $212.69 LIST OF CONDITIONS Roll off container company must be on City approved list . Container cannot be placed on City right-of-way. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION. ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES . ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY. 1 of 2Issued Date: 7/29/2022 PERMIT NUMBER ROOF22-0041 ISSUED: 7/29/2022 EXPIRES: 1/25/2023 ROOF NON SHINGLE PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 NEMO|etc. Certificate of Authorization #32455 353 Christian Street, Unit #13 Oxford, CT 06478 (203) 262-9245 ENGINEER EVALUATE TEST CONSULT EVALUATION REPORT BY FLORIDA P.E. CertainTeed, LLC 20 Moores Road Malvern, PA 19355 (610) 893-5400 Evaluation Report 3520.03.04-R29 FL2533-R28 Date of Issuance: 09/19/2005 Revision 29: 04/14/2022 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code. The product described herein has been evaluated for compliance with the 7th Edition (2020) Florida Building Code sections noted herein. DESCRIPTION: Flintlastic® Modified Bitumen Roof Systems for use in FBC non-HVHZ jurisdictions LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance or production facility location(s) changes, or Code provisions that relate to the product(s) change. Acceptance of our Evaluation Reports by the named client constitutes agreement to notify NEMO ETC, LLC of any changes to the product(s), the Quality Assurance or the production facility location(s). NEMO ETC, LLC requires a complete review of its Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Florida Product Approval Number (FL#) preceded by the words “NEMO P.E. Evaluated” may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 5, plus a 70-page Appendix. Prepared by: Robert J.M. Nieminen, P.E. Florida Registration No. 59166, Florida DCA ANE1983 The facsimile seal appearing was authorized by Robert Nieminen, P.E. on 04/14/2022. This does not serve as an electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. NEMO ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. © 2019 NEMO ETC, LLC By Mike Jones at 4:05 pm, Jul 28, 2022 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R29 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) FL2533-R28 Flintlastic® Modified Bitumen Roof Systems Revision 29: 04/13/2022 Page 2 of 5 ROOFING SYSTEMS EVALUATION: 1. SCOPE: Product Category: Roofing Sub-Category: Modified Bitumen Roof Systems Product Approval Method: Method 1, Option D – Codified Material, Evaluation by Engineer Compliance Statement: Flintlastic® Modified Bitumen Roof Systems, as produced by CertainTeed, LLC, have demonstrated compliance with the following sections of the 7th Edition (2020) Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: SECTION PROPERTY STANDARD YEAR 1504.3.1 Wind resistance FM 4474 2011 1504.6 Accelerated weathering ASTM G155 2013 1504.7 Impact resistance FM 4470 2016 1507.1.1 Material standard ASTM D1970 2015 1507.10.2 Material standard ASTM D41 2011 1507.10.2 Material standard ASTM D2178 2015 1507.10.2 Material standard ASTM D4601 2012 1507.10.2 Material standard ASTM D4897 2009 1507.11.2 Material standard ASTM D6163 2015 1507.11.2 Material standard ASTM D6164 2011 1507.11.2 Material standard ASTM D6222 2011 1507.11.2 Material standard ASTM D6509 2015 3. REFERENCES: ENTITY EXAMINATION REFERENCE DATE ENTITY EXAMINATION REFERENCE DATE ERD (TST6049) ASTM G155 C31410.06.10-2-R1 01-10-11 FM (TST1867) FM 4470 0E3A2.AM 03-30-82 ERD (TST6049) ASTM G155 C31410.12.13 12-05-13 FM (TST1867) FM 4470 3W0A4.AM 03-16-93 ERD (TST6049) ASTM D6222 CTR-SC11145.09.16-7A 09-19-16 FM (TST1867) FM 4470 3W0A2.AM 03-17-93 ERD (TST6049) ASTM D1970 CTR-SC11145.10.16 10-31-16 FM (TST1867) FM 4470 3W0A3.AM 03-17-93 NEMO (TST6049) ASTM D4601 4q-CTR-20-SSMBB-03.A 02-10-21 FM (TST1867) FM 4470 1Z4A6.AM 09-11-96 NEMO (TST6049) ASTM D4897 4q-CTR-21-SSMBB-03.A 10-05-21 FM (TST1867) FM 4470 3Y8A1.AM 09-30-96 NEMO (TST6049) ASTM D6222, G155 4q-CTR-21-SSMBB-04.E 03-08-22 FM (TST1867) FM 4470 2D5A9.AM 06-22-99 NEMO CERT (CER13842) Various Various 04-15-22 FM (TST1867) FM 4470 3009502 12-12-00 PRI (TST5878) ASTM D6164, G155 CTC-093-02-01 08-08-11 FM (TST1867) FM 4470 3008869 03-19-01 PRI (TST5878) ASTM D6222, G155 CTC-071-02-01 08-08-11 FM (TST1867) FM 4470 3009610 10-15-01 PRI (TST5878) ASTM D4601 CTC-124-02-01 03-12-12 FM (TST1867) FM 4470 3006025 12-28-01 PRI (TST5878) ASTM D6509 CTC-116-02-01 04-04-12 FM (TST1867) FM 4470 3012321 07-29-02 PRI (TST5878) ASTM D6164 CTC-131-02-01 06-08-12 FM (TST1867) FM 4470 3009814 09-06-02 PRI (TST5878) ASTM D6164, G155 CTC-161-02-01 05-09-13 FM (TST1867) FM 4470 3014502 04-04-03 PRI (TST5878) ASTM D6164 CTC-190-02-01 11-27-13 FM (TST1867) FM 4470 3015444 07-11-03 PRI (TST5878) ASTM D6164 CTC-354-02-01 05-11-18 FM (TST1867) FM 4470 3014692 08-05-03 PRI (TST5878) ASTM D41 256T0074 11-11-21 FM (TST1867) FM 4470 3014751 08-27-03 ERD (TST6049) FM 4470 3504.06.01-1 06-05-01 FM (TST1867) FM 4470 3018579 10-09-03 ERD (TST6049) FM 4470 3513.08.02 08-15-02 FM (TST1867) FM 4470/4474 3020703 07-30-04 ERD (TST6049) FM 4470 03515.07.03 07-22-03 FM (TST1867) FM 4470/4474 3021759 06-03-05 ERD (TST6049) FM 4470 3519.12.03 12-22-03 FM (TST1867) FM 4470/4474 3022038 04-05-06 ERD (TST6049) FM 4470/4474 3522.07.04 07-28-04 FM (TST1867) FM 4470/4474 3023458 07-18-06 ERD (TST6049) FM 4470/4474 02843.02.05-11 02-10-05 FM (TST1867) FM 4470/4474 3026128 08-04-06 ERD (TST6049) FM 4470/4474 3533.01.06 01-06-06 FM (TST1867) FM 4470/4474 3024311 11-01-06 ERD (TST6049) FM 4470/4474 4674.11.01-1 03-21-06 FM (TST1867) FM 4470/4474 3025766 11-13-06 ERD (TST6049) FM 4470/4474 3521.07.04-R1 10-26-07 FM (TST1867) FM 4470/4474 3028410 02-19-07 ERD (TST6049) FM 4470/4474 02762.03.05-R1 12-10-07 FM (TST1867) FM 4470/4474 3026964 07-25-07 ERD (TST6049) FM 4470/4474 02764.09.05-R1 12-10-07 FM (TST1867) FM 4470/4474 3031262 11-30-07 ERD (TST6049) FM 4470/4474 P6860.06.07-R1 09-10-09 FM (TST1867) FM 4470/4474 3031199 12-23-08 ERD (TST6049) FM 4470/4474 C8370.08.08-R1 10-05-09 FM (TST1867) FM 4470/4474 3032172 06-12-09 ERD (TST6049) FM 4470/4474 C30310.12.09 12-17-09 FM (TST1867) FM 4470/4474 3037127 01-11-10 ERD (TST6049) FM 4470/4474 C30560.03.10 03-18-10 FM (TST1867) FM 4470/4474 3039848 12-02-11 ERD (TST6049) FM 4470/4474 C31420.08.10 09-21-10 FM (TST1867) FM 4470/4474 3046104 08-13-13 ERD (TST6049) FM 4470/4474 C33980.12.10 12-22-10 FM (TST1867) FM 4470/4474 3048520 09-19-13 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R29 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) FL2533-R28 Flintlastic® Modified Bitumen Roof Systems Revision 29: 04/13/2022 Page 3 of 5 ENTITY EXAMINATION REFERENCE DATE ENTITY EXAMINATION REFERENCE DATE ERD (TST6049) FM 4470/4474 C33830.02.11 02-08-11 FM (TST1867) FM 4470/4474 3055491 12-05-16 ERD (TST6049) Criticality C35500.02.11 02-09-11 FM (TST1867) FM 4470/4474 3063970 09-14-18 ERD (TST6049) FM 4470/4474 C37820.07.12 07-24-12 FM (TST1867) FM 4470/4474 3061328 04-13-20 ERD (TST6049) FM 4470/4474 C37830.07.12 07-26-12 FM (TST1867) FM 4470/4474 PR458318 04-12-21 ERD (TST6049) Criticality C42110.08.12 08-13-12 FM (TST1867) FM 4470 RR228436 06-01-21 ERD (TST6049) FM 4470/4474 C39670.08.12 08-20-12 NEMO Traceability FBC Cross-Listing 07-02-21 ERD (TST6049) FM 4470/4474 C42280.08.12 08-20-12 NEMO (TST11294) FM 4474 2L-CTR-18-001.04.19.A 06-24-19 ERD (TST6049) Criticality A35880.04.12-R1 10-26-12 NEMO (TST6049) FM 4474 4L-CTR-18-002.09.18-1 09-21-18 ERD (TST6049) FM 4470/4474 C44580.07.13 07-25-13 NEMO (TST6049) FM 4474 4L-CTR-18-002.09.18-2 09-21-18 ERD (TST6049) FM 4470/4474 C46090.11.13-A 11-20-13 NEMO (TST6049) FM 4474 4L-CTR-18-002.10.18 10-22-18 ERD (TST6049) FM 4470/4474 C45620.03.14 03-27-14 NEMO (TST6049) FM 4474 4L-CTR-18-002.03.19A 03-07-19 ERD (TST6049) FM 4470/4474 C46760.06.14 06-19-14 NEMO (TST6049) FM 4474 4L-CTR-18-002.04.19B 04-12-19 ERD (TST6049) FM 4470/4474 C47320.03.14-R1 04-01-15 NEMO (TST6049) FM 4474 4a-CTR-19-LSWUS-04.A 08-05-19 ERD (TST6049) FM 4470/4474 CTR-SC8995.10.15 10-14-15 NEMO (TST6049) FM 4474 4a-CTR-19-LSWUS-03.B 01-27-20 ERD (TST6049) FM 4470/4474 CTR-SC9935.01.16 01-14-16 NEMO (TST6049) FM 4474 4a-CTR-19-LSWUS-05.A 02-05-20 ERD (TST6049) FM 4470 CTR-SC9920.01.16 01-20-16 NEMO (TST6049) FM 4474 4a-CTR-19-LSWUS-02.A 02-28-20 ERD (TST6049) FM 4470/4474 CTR-SC10420.01.16 01-25-16 NEMO (TST6049) Criticality 4p-ICP-19-SSLAP-04.A 05-28-20 ERD (TST6049) FM 4470/4474 CTR-SC11590.08.16 09-06-16 NEMO (TST6049) FM 4474 4a-CTR-20-LSWUS-01.B 06-26-20 ERD (TST6049) FM 4470/4474 CTR-SC9175.09.16-1 09-06-16 NEMO (TST6049) Criticality 4i-CTR-20-SSCRT-04.A 06-16-21 ERD (TST6049) FM 4470/4474 CTR-SC9175.09.16-1 09-06-16 NEMO (TST6049) Criticality 4i-CTR-21-SSCRT-02.A 06-21-21 ERD (TST6049) FM 4470/4474 CTR-SC12255.12.16 12-27-16 NEMO (TST6049) Criticality 4i-CTR-21-SSCRT-03.A 07-06-21 ERD (TST6049) Criticality ICP-SC15630.09.17 09-06-17 NEMO (TST6049) Criticality 4i-CTR-21-SSCRT-01.A 07-12-21 ERD (TST6049) Criticality ICP-SC16225.09.17 09-06-17 NEMO (TST6049) FM 4474 4a-CTR-21-LSWUS-01 11-29-21 ERD (TST6049) FM 4474 CTR-SC15775.17 09-13-17 NEMO (TST6049) Criticality 4i-CRT-21-SSCRT-04.A 01-04-22 PRI (TST5878) FM 4474 2111T0009 05-13-21 4. PRODUCT DESCRIPTION: This Evaluation Report covers Flintlastic® Modified Bitumen Roof Systems installed in accordance with CertainTeed, LLC published installation instructions and the Limitations / Conditions of Use herein. TABLE 1: EVALUATED MEMBRANES TYPE PRODUCT MATERIAL STANDARD PLANT(S) REFERENCE TYPE GRADE Base Sheets Flintlastic® SA NailBase ASTM D4601 II N/A Little Rock, AR1 Glasbase™ Base Sheet ASTM D4601 II N/A Pryor, OK Little Rock, AR All Weather/Empire™ Base Sheet ASTM D4601 II N/A Little Rock, AR1 Flintlastic® Base 20 ASTM D4601 II N/A Little Rock, AR1 Flintlastic® Poly SMS Base Sheet ASTM D4601 (except glass mat is N/A) II N/A Little Rock, AR1 Flintglas® MS Cap (inverted) ASTM D4897 II N/A Little Rock, AR Ply Sheets Flintglas® Ply 4 ASTM D2178 IV N/A Pryor, OK1 Base/Ply Membranes (APP) Flintlastic® APP Base T ASTM D6509 N/A N/A Little Rock, AR Flintlastic® STA ASTM D6222 I S Little Rock, AR Flintlastic® STA Plus ASTM D6222 I S Little Rock, AR Cap Membranes (APP) Flintlastic® STA ASTM D6222 I S Little Rock, AR Flintlastic® STA Plus ASTM D6222 I S Little Rock, AR Flintlastic® GTA ASTM D6222 I G Little Rock, AR1 Flintlastic® GTA CoolStar® ASTM D6222 I G Little Rock, AR Flintlastic® GTA-FR ASTM D6222 I G Little Rock, AR1 Flintlastic® GTA-FR CoolStar® ASTM D6222 I G Little Rock, AR NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R29 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) FL2533-R28 Flintlastic® Modified Bitumen Roof Systems Revision 29: 04/13/2022 Page 4 of 5 TABLE 1 (CONTINUED): EVALUATED MEMBRANES TYPE PRODUCT MATERIAL STANDARD PLANT(S) REFERENCE TYPE GRADE Base/Ply Membranes (SBS) Black Diamond® Base Sheet ASTM D1970 N/A N/A Shakopee, MN Flintlastic® SA PlyBase ASTM D1970 N/A N/A Little Rock, AR Flintlastic® SA Mid Ply ASTM D6163 I S Little Rock, AR1 Flintlastic® Ultra Glass SA ASTM D6163 I S Little Rock, AR1 Flintlastic® Base 20 ASTM D6163 I S Little Rock, AR1 Flintlastic® Base 20 T ASTM D6163 I S Little Rock, AR1 Flintlastic® Ultra Poly SMS Base Sheet ASTM D6164 I S Little Rock, AR Cap Membranes (SBS) Flintlastic® SA Cap FR ASTM D6163 I G Little Rock, AR1 Flintlastic® SA Cap FR CoolStar® ASTM D6163 I G Little Rock, AR Flintlastic® SA Cap ASTM D6164 I G Little Rock, AR Flintlastic® SA Cap CoolStar® ASTM D6164 I G Little Rock, AR Flintlastic® FR-P ASTM D6164 I G Little Rock, AR Flintlastic® FR-P CoolStar® ASTM D6164 I G Little Rock, AR Flintlastic® GMS ASTM D6164 I G Little Rock, AR Flintlastic® Premium FR-P ASTM D6164 II G Little Rock, AR Flintlastic® Premium FR-P CoolStar® ASTM D6164 II G Little Rock, AR 1 Indicates membrane/plant combination is Certified by ISO/IEC 17065 Certification Entity; NEMO|cert. to the noted standard. Refer to www.nemocert.com for details. 5. LIMITATIONS: 5.1 This is a Building Code Evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC High Velocity Hurricane Zone jurisdictions (i.e., Broward and Miami- Dade Counties). 5.3 This Evaluation Report pertains to above-deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. 5.4 This Evaluation Report does not include evaluation of fire classification. Refer to FBC 1505 for requirements and limitations regarding roof assembly fire classification. Refer to FBC 2603 for requirements and limitations concerning the use of foam plastic insulation. 5.5 This Evaluation Report does not include evaluation of roof edge termination. Refer to FBC 1504.5 for requirements and limitations regarding edge securement for low-slope roofs. 5.6 Refer to FBC 1511 for requirements and limitations regarding recover installations. 5.6.1 For mechanically attached components over existing roof decks, fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the minimum requirements for the system. Testing shall be in accordance with ANSI/SPRI FX-1 or Testing Application Standard TAS 105. 5.6.2 For bonded insulation or membrane over existing substrates in a re-roof (tear off) or recover installation, the existing deck or existing roof surface shall be examined for compatibility with the adhesive to be installed. If any surface conditions exist that bring system performance into question, field uplift testing in accordance with ANSI/SPRI IA-1, ASTM E907, FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124 shall be conducted on mock-ups of the proposed new roof assembly. 5.6.3 For bonded insulation or membrane over existing substrates in a recover installation, the existing roof system shall be capable of resisting project design pressures on its own merit to the satisfaction of the Authority Having Jurisdiction, as documented through field uplift testing in accordance with ASTM E907, FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124. NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R29 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) FL2533-R28 Flintlastic® Modified Bitumen Roof Systems Revision 29: 04/13/2022 Page 5 of 5 5.7 Refer to Appendix 1 for system attachment requirements for wind load resistance. 5.7.1 “MDP” = Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FBC 1609 for determination of design wind loads. 5.7.2 For mechanically attached components or partially-bonded insulation, the maximum design pressure for the selected assembly shall meet or exceed at least the Zone 1 PRIME design pressure determined in accordance with FBC Chapter 16. Elevated pressure zones shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29, Roofing Application Standard RAS 117 and Roofing Application Standard RAS 137. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (February 2020) for Zone 2/3 enhancements. 5.7.3 For assemblies with all components fully bonded in place, the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16. No rational analysis is permitted for these systems. 5.8 All components in the roof assembly shall have quality assurance audit in accordance with F.A.C. Rule 61G20-3. Refer to the Product Approval of the component manufacturer for components listed in Appendix 1 that are produced by a Product Manufacturer other than the report holder on Page 1 of this Evaluation Report. 6. INSTALLATION: Flintlastic® Modified Bitumen Roof Systems shall be installed in accordance with CertainTeed, LLC published installation instructions, subject to the Limitations / Conditions of Use herein. 7. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction to properly evaluate the installation of this product. 8. MANUFACTURING PLANTS: Contact the named QA entity for manufacturing facilities covered by F.A.C. Rule 61G20-3 QA requirements. Refer to Section 4 herein for products and production locations having met codified material standards. 9. QUALITY ASSURANCE ENTITY: UL, LLC – QUA9625: (360) 817-5512; bsai.inspections@ul.com - THE 70-PAGES THAT FOLLOW FORM PART OF THIS EVALUATION REPORT - NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R29 for FL2533-R28 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 29: 04/14/2022 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 1 of 70 APPENDIX 1: ATTACHMENT REQUIREMENTS FOR WIND UPLIFT RESISTANCE TABLE DECK APPLICATION TYPE DESCRIPTION PAGE 1A Wood New or Reroof (Tear-Off) A-1 Bonded Insulation, Bonded Roof Cover 6 1B Wood New or Reroof (Tear-Off) A-2 Mechanically Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 7-8 1C Wood New, Reroof (Tear-Off) or Recover B-1 Mechanically Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 9 1D Wood New, Reroof (Tear-Off) or Recover C-1 Mechanically Attached Insulation, Bonded Roof Cover 9-11 1E Wood New, Reroof (Tear-Off) or Recover D-2 Insulated, Mechanically Attached Base Sheet, Bonded Roof Cover 11-13 1F Wood New, Reroof (Tear-Off) E-2 Non-Insulated, Mechanically Attached Base Sheet, Bonded Roof Cover 13-16 1G Wood New, Reroof (Tear-Off) or Recover E-2 Non-Insulated, Mechanically Attached Base Sheet, Bonded Roof Cover 16-18 1H Wood New or Reroof (Tear-Off) F Non-Insulated, Bonded Roof Cover 18 2A Steel or Structural concrete New, Reroof (Tear-Off) or Recover B-1 Mechanically Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 19-21 2B Steel or Structural concrete New, Reroof (Tear-Off) or Recover C-1 Mechanically Attached Insulation, Bonded Roof Cover 22-25 2C Steel or Structural concrete New, Reroof (Tear-Off) or Recover D-2 Insulated, Mechanically Attached Base Sheet, Bonded Roof Cover 26-28 3A Structural concrete New or Reroof (Tear-Off) A-1 Bonded Insulation, Bonded Roof Cover 29-37 3B Structural concrete New or Reroof (Tear-Off) A-3 Bonded Temp Roof/Vapor Barrier, Bonded Insulation, Bonded Roof Cover 37 3C Structural concrete New or Reroof (Tear-Off) F Non-Insulated, Bonded Roof Cover 38 4A LWIC / steel New or Reroof (Tear-Off) A-1 Bonded Insulation, Bonded Roof Cover 39-40 4B LWIC / structural concrete New or Reroof (Tear-Off) A-1 Bonded Insulation, Bonded Roof Cover 41-45 4C LWIC / structural concrete New, Reroof (Tear-Off) A-1 Bonded Vapor Barrier, Bonded Insulation, Bonded Roof Cover 46-47 4D LWIC / steel New or Reroof (Tear-Off) A-2 Mechanically Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 48-50 4E LWIC / steel or struct. conc. New or Reroof (Tear-Off) E-2 Non-Insulated, Mechanically Attached Base Sheet, Bonded Roof Cover 51-55 4F LWIC / steel Reroof (Tear-Off) or Recover E-2 Non-Insulated, Mechanically Attached Base Sheet, Bonded Roof Cover 56 4G LWIC / steel Reroof (Tear-Off) F Non-Insulated, Bonded Roof Cover 56 5A Cementitious wood fiber New or Reroof (Tear-Off) A-1 Bonded Insulation, Bonded Roof Cover 57-58 5B Cementitious wood fiber New or Reroof (Tear-Off) or Recover A-2 Mechanically Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 59 5C Cementitious wood fiber Reroof (Tear-Off) or Recover C-1 Mechanically Attached Insulation, Bonded Roof Cover 60 5D Cementitious wood fiber New, Reroof (Tear-Off) or Recover E-2 Non-Insulated, Mechanically Attached Base Sheet, Bonded Roof Cover 60 6A Existing gypsum Reroof (Tear-Off) A-1 Bonded Insulation, Bonded Roof Cover 61-62 6B Existing gypsum Reroof (Tear-Off) A-2 Mechanically Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 63 6C Existing gypsum Reroof (Tear-Off) C-1 Mechanically Attached Insulation, Bonded Roof Cover 64 6D Existing gypsum Reroof (Tear-Off) E-2 Non-Insulated, Mechanically Attached Base Sheet, Bonded Roof Cover 64 7A Various Recover A-1 Bonded Insulation, Bonded Roof Cover 65-70 7B Various Recover F Non-Insulated, Bonded Roof Cover 70 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R29 for FL2533-R28 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 29: 04/14/2022 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 2 of 70 The following notes apply to the systems outlined herein: 1 The roof system evaluation herein pertains to above-deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. 2 Unless otherwise noted, fasteners and stress plates shall be as follows. Fasteners shall be of sufficient length for the following engagements: FASTENER/PLATE OPTIONS DECK TYPE BY FBC FILE PARTS MINIMUM ENGAGEMENT Wood Altenloh, Brinck and Co. U.S., Inc. FL4500 Trufast #14 HD with Trufast 3” Metal Insulation Plates Minimum ¾-inch plywood penetration or minimum 1-inch wood plank embedment OMG, Inc. FL699 OMG #14 Roofgrip with AccuTrac Plates or OMG #14 Heavy Duty with OMG 3 in. Galvalume Steel Plate SFS Group USA, Inc. FL20311 Dekfast DF-#14-PH3 with Dekfast PLT-H-2-7/8 or Dekfast PLT-R-3. Steel Altenloh, Brinck and Co. U.S., Inc. FL4500 Trufast #12 DP or Trufast #14 HD with Trufast 3” Metal Insulation Plates Minimum ¾-inch steel penetration and engage the top flute of the steel deck OMG, Inc. FL699 OMG #12 or #14 Roofgrip with AccuTrac Plates or OMG #12 Standard or OMG #14 Heavy Duty with OMG 3 in. Galvalume Steel Plate SFS Group USA, Inc. FL20311 Dekfast DF-#12-PH3 or DF-#14-PH3 with Dekfast PLT-H-2-7/8 or Dekfast PLT-R-3. Structural Concrete Altenloh, Brinck and Co. U.S., Inc. FL4500 Trufast #14 HD or Trufast Fluted Concrete Nail with Trufast 3” Metal Insulation Plates Minimum 1-inch embedment. Fasteners installed with a pilot hole in accordance with the fastener manufacturer’s published installation instructions OMG, Inc. FL699 OMG #14 Roofgrip with AccuTrac Plates or OMG #14 Heavy Duty or CD-10 with OMG 3 in. Galvalume Steel Plate SFS Group USA, Inc. FL20311 Dekfast DF-#14-PH3 with Dekfast PLT-H-2-7/8 or Dekfast PLT-R-3. 3 Unless otherwise noted, insulation may be any one layer or combination of FBC Approved (Local or Statewide) board(s) that meet FBC 1505 and, for foam plastic, FBC Chapter 26, when installed with the roof cover. 4 Minimum 200 psi, minimum 2-inch FBC Approved lightweight insulating concrete may be substituted for, or installed below, rigid insulation board for System Types B-1, C-1, C-2, D-1 or D-2, whereby fasteners are installed through the lightweight insulating concrete to engage the structural deck. The structural deck shall be of equal or greater type, thickness and strength to the steel and structural concrete deck listings. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. This is a wind uplift resistance allowance and does not purport to address non-wind-uplift-related issues, such as deck venting or moisture levels within the Lightweight Concrete and the potential effect on overlying components. 5 Preliminary insulation attachment for System Type D: Unless otherwise noted, refer to Section 2.2.10.1.3 of FM Loss Prevention Data Sheet 1-29 (February 2020). 6 Unless otherwise noted, insulation adhesive application rates are as follows. Ribbon or bead width is at the time of application; the ribbons/beads shall expand as noted in the manufacturer’s published instructions. When multiple layers(s) of insulation and/or coverboard are installed in ribbon-applied adhesive, board joints shall be staggered. The maximum edge distance from the adhesive ribbon to the edge of the insulation board shall be not less than one-half the specified ribbons spacing. INSULATION ADHESIVE REFERENCES BY FBC FILE ADHESIVE REFERENCE MINIMUM RATE NOTE DuPont de Nemours, Inc. FL720 Insta Stik Quik Set Insta Stick Continuous 0.75 to 1 inch wide ribbons, 12-inch o.c H.B. Fuller Company FL1800 Millennium One Step Foamable Adhesive M-OSFA Continuous 0.25 to 0.5-inch wide ribbons, 12-inch o.c. H.B. Fuller Company FL1800 Millennium PG-1 Pump Grade Adhesive M-PG1 Continuous 0.5 to 0.75-inch wide ribbons, 12-inch o.c. ICP Construction, Inc. FL22256 Polyset Board-Max Polyset BM Continuous 3-inch wide ribbons, 12-inch o.c. ICP Construction, Inc. FL1365 Polyset Commercial Roofing Adhesive Polyset CRA Continuous 2.5 to 3-inch wide ribbons, 12-inch o.c. Formerly Polyset CR-20 OMG, Inc. FL1608 OlyBond 500 Adhesive Fastener OB500 Continuous 0.75-inch wide ribbons, 12-inch o.c. PaceCart, SpotShot or Canister dispensing Generic, ASTM D312, Type IV N/A hot asphalt N/A Full coverage at 25-30 lbs/square If applying hot asphalt to concrete deck, deck shall be primed with ASTM D41 primer NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R29 for FL2533-R28 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 29: 04/14/2022 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 3 of 70 7 Unless otherwise noted, all insulations are flat-stock or taper board of the minimum thickness noted. Tapered polyisocyanurate at the following thickness limitations may be substituted with the following Maximum Design Pressure (MDP) limitations. In no case shall these values be used to ‘increase’ the MDP listings in the tables; rather if MDP listing below meets or exceeds that listed for a particular system in the tables, then the thinner board listed below may be used as a drop-in for the equivalent thicker material listed in the table. MDP LIMITATIONS FOR TAPERED POLYISOCYANURATE INSULATIONS ADHESIVE INSULATION MIN. TAPERED THICKNESS (IN) MDP (PSF) LISTED PRODUCT FBC FILE Insta Stik Any polyisocyanurate listed with adhesive herein Various 1.0 -120.0 M-OSFA Any polyisocyanurate listed with adhesive herein Various 1.0 -157.5 M-PG1 Any polyisocyanurate listed with adhesive herein Various 1.0 -157.5 Polyset CRA Any polyisocyanurate listed with adhesive herein Various 1.0 -117.5 OB500 Rmax Multi-Max FA3 FL11207 0.5 -45.0 OB500 Hunter H-Shield FL5968 0.5 -315.0 OB500 Johns Manville ENRGY 3 FL4205 0.5 -315.0 OB500 Atlas Roofing ACFoam II FL17989 0.5 -487.5 8 For adhered roof insulation and board-size: Unless otherwise noted, refer to Section 2.2.10.6.2 of FM Loss Prevention Data Sheet 1-29 (February 2020). 9 For mechanically attached components or partially-bonded insulation, the maximum design pressure for the selected assembly shall meet or exceed at least the Zone 1 PRIME design pressure determined in accordance with FBC Chapter 16. Elevated pressure zones shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29, Roofing Application Standard RAS 117 and Roofing Application Standard RAS 137. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (February 2020) for Zone 2/3 enhancements. 10 For assemblies with all components fully bonded, the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16. No rational analysis is permitted for these systems. 11 For mechanically attached components over existing decks, fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the minimum requirements for the system. Testing and analysis shall be in accordance with ANSI/SPRI FX-1 or Testing Application Standard TAS 105. 12 For bonded insulation or membrane over existing substrates in a re-roof (tear off) or recover installation, the existing deck or existing roof surface shall be examined for compatibility with the adhesive to be installed. If any surface conditions exist that bring system performance into question, field uplift testing shall be conducted on mock-ups of the proposed new roof assembly. For bonded insulation or membrane over existing substrates in a recover installation, the existing roof system shall be capable of resisting project design pressures on its own merit to the satisfaction of the Authority Having Jurisdiction, as documented through field uplift testing. Field uplift testing shall be in accordance with ASTM E907, FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124. 13 Refer to FBC 1511 for requirements and limitations regarding recover installations. For Structural Concrete Deck or Recover Applications using System Type C-1 the base insulation layer is optional and for System Type C-2, D-1 or D-2, the insulation is optional. Alternatively, an FBC Approved insulation board or coverboard may be used as a separation layer. Board products shall be preliminarily attached prior to roof cover installation (Note 5 herein). The separator component shall be documented as meeting FBC 1505 and, for foam plastic, FBC Chapter 26, when installed with the roof cover in Recover applications. 14 Lightweight insulating concrete (LWIC) shall be cast in accordance with FBC Section 1917 to the satisfaction of the Authority Having Jurisdiction. For systems where specific LWIC is referenced, refer to current LWIC Product Approval for specific deck construction and limitations. Unless otherwise noted, for systems where specific LWIC is not referenced, the minimum design mix shall be 300 psi. In all cases, the minimum top-coat thickness is 2-inches. For LWIC over structural concrete, reference is made to FBC Section 1917.4.1, Point 1. For “pre-existent” LWIC references, listings were established through testing over lightweight concrete cast using only foaming agent (ASTM C896), water and Portland cement (ASTM C150), with no proprietary additives, in accordance with procedures adopted by Miami-Dade BCCO (FBC CER1592). Use of these listings in new construction or re-roof (tear-off) applications is at the discretion of the Designer or Record and Authority Having Jurisdiction. NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R29 for FL2533-R28 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 29: 04/14/2022 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 4 of 70 15 For bonded membrane applications, unless otherwise noted, refer to the following. MEMBRANE / ADHESIVE COMBINATIONS REFERENCE LAYER MATERIAL APPLICATION SBS-CA1 Base Ply: Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Karnak No. 81 Cold Process Modified Bitumen Adhesive Brush Grade at 1 gal/square Note: Base ply cures overnight prior to application of the ply or cap ply. Ply: Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Cap Ply: Flintlastic FR-P, Flintlastic FR-P CoolStar, Flintlastic Premium FR-P, Flintlastic Premium FR-P CoolStar, Flintlastic GMS BP-CA2 Base Ply: Glasbase Base Sheet, All Weather/Empire Base Sheet, Flintlastic Base 20 Henry #903 Adhesive at 1.5 gal/square. SBS-CA2 Base Ply: Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Ply: Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Cap Ply: Flintlastic FR-P, Flintlastic FR-P CoolStar, Flintlastic Premium FR-P, Flintlastic Premium FR-P CoolStar, Flintlastic GMS BP-CA3 Base Ply: Glasbase Base Sheet, All Weather/Empire Base Sheet, Flintlastic Base 20 HB Fuller “Millennium Hurricane Force Membrane Adhesive”, beads spaced 6-inch o.c. SBS-CA3 Base Ply: Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Ply: Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Cap Ply: Flintlastic FR-P, Flintlastic FR-P CoolStar, Flintlastic Premium FR-P, Flintlastic Premium FR-P CoolStar, Flintlastic GMS SBS-CA4 Base Ply: Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base FlintBond Brush or Tropical Roofing Products #216 Modified Bitumen Adhesive at 1 to 1.5 gal/square. Note: Base ply cures overnight prior to application of the ply or cap ply. Ply: Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Cap Ply: Flintlastic FR-P, Flintlastic FR-P CoolStar, Flintlastic Premium FR-P, Flintlastic Premium FR-P CoolStar, Flintlastic GMS BP-AA Base Ply: Glasbase Base Sheet, All Weather/Empire Base Sheet, Flintlastic Base 20 hot asphalt at 20-40 lbs/square Ply: One or more Flintglas Ply 4 BP-AA2 Base Ply: Flintglas MS Cap (inverted) hot asphalt in 24-inch diameter spots in 30-inch grid pattern BP-AA3 Base Ply: Flintglas MS Cap (inverted) hot asphalt in 9-inch diameter spots in grid pattern noted herein. BP-AA4 Base Ply: Flintglas MS Cap (inverted) hot asphalt in 9-inch wide ribbons spaced as noted herein. SBS-AA Base Ply: Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base hot asphalt at 20-40 lbs/square Ply: One or more Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Cap Ply: Flintlastic FR-P, Flintlastic FR-P CoolStar, Flintlastic Premium FR-P, Flintlastic Premium FR-P CoolStar, Flintlastic GMS SBS-TA Base Ply: Flintlastic Ultra Poly SMS Base Sheet, Flintlastic Base 20 T torch-applied Ply: One or more Flintlastic Ultra Poly SMS Base Sheet, Flintlastic Base 20 T APP-TA Base Ply: One or more Flintlastic APP Base T, Flintlastic STA, Flintlastic STA Plus torch-applied Cap Ply: Flintlastic STA, Flintlastic STA Plus, Flintlastic GTA, Flintlastic GTA CoolStar, Flintlastic GTA-FR, Flintlastic GTA-FR CoolStar SBS-SA-H Base Ply: Black Diamond Base Sheet, Flintlastic Ultra Glass SA self-adhering (activated by overlying membrane) SBS-SA Base Ply: Flintlastic SA PlyBase, Flintlastic SA Mid Ply self-adhering Ply: Flintlastic SA PlyBase, Flintlastic SA Mid Ply Cap Ply: Flintlastic SA Cap, Flintlastic SA Cap CoolStar, Flintlastic SA Cap FR, Flintlastic SA Cap FR CoolStar NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R29 for FL2533-R28 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 29: 04/14/2022 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 5 of 70 16 Vapor barrier options for use over structural concrete deck followed by bonded insulation carry the following MDP limitations. The lesser of the MDP listings below vs. that for the selected assembly from TABLE 3A applies. VAPOR BARRIER OPTIONS, STRUCTURAL CONCRETE DECK, ADHERED INSULATION OPTION # PRIMER VAPOR BARRIER INSULATION ADHESIVE PER TABLE 3A MDP (PSF) TYPE ATTACH C-VB-1. FlintPrime QD Flintlastic SA PlyBase Self-adhering OB500, 12-inch o.c. -82.5 C-VB-2. None All Weather/Empire Base Sheet, 3-inch wide side laps and 6-inch wide end laps are sealed with HB Fuller “HB Fuller “Millennium Hurricane Force Lap and Flashing Adhesive” HB Fuller “Millennium Hurricane Force Membrane Adhesive HS”, max. 6-inch o.c. M-OSFA or M-PG1, 12-inch o.c. -82.5 C-VB-3. None Flintlastic Ultra Poly SMS Base Sheet, 3-inch wide side laps and 6-inch wide end laps are hot-air-welded, torch-welded or sealed with HB Fuller “HB Fuller “Millennium Hurricane Force Lap and Flashing Adhesive” HB Fuller “Millennium Hurricane Force Membrane Adhesive HS”, max. 6-inch o.c. M-OSFA or M-PG1, 12-inch o.c. -82.5 C-VB-4. FlintPrime QD Black Diamond Base Sheet, Flintlastic Ultra Glass SA or Flintlastic SA Cap Self-adhering M-OSFA or M-PG1, 12-inch o.c. -97.5 C-VB-5. FlintPrime QD Black Diamond Base Sheet, Flintlastic Ultra Glass SA or Flintlastic SA Cap Self-adhering M-OSFA or M-PG1, 6-inch o.c. -315.0 C-VB-6. FlintPrime QD Flintlastic GTA Torch-applied M-OSFA or M-PG1, 12-inch o.c. -420.0 C-VB-7. FlintPrime QD Flintlastic Base 20 T Torch-applied M-OSFA or M-PG1, 12-inch o.c. -495.0 17 The following products are interchangeable within the scope of this Evaluation Report. ACCEPTABLE ALTERNATES SUB-CATEGORY MANUFACTURER FBC FILE LISTED PRODUCT HEREIN ALTERNATE Adhesives H.B. Fuller Company FL1800 M-OSFA FlintFast QS Insulation Adhesive M-PG1 FlintFast LV Insulation Adhesive Roofing Fasteners Altenloh, Brinck and Co. U.S., Inc. FL4500 Trufast #12 DP FlintFast #12 Fastener Trufast #14 HD FlintFast #14 Fastener Trufast #15 EHD FlintFast #15 EHD Fastener Trufast 2” Barbed Metal Seam Plate FlintFast 2” Barbed Seam Plate Trufast 2.4” Barbed Metal Seam Plate FlintFast 2.4” Barbed Seam Plate Trufast 3” Metal Insulation Plate FlintFast 3” Insulation Plate Roofing Insulation Atlas Roofing FL17989 ACFoam II FlintBoard ISO ACFoam III FlintBoard ISO Cold Hunter Panels FL5968 H-Shield FlintBoardH ISO H-Shield CG FlintBoardH ISO Cold Georgia-Pacific Gypsum, LLC FL1250 DensDeck Prime DensDeck StormX Prime Roof Board 18 “MDP” = Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads. Refer to FBC 1609 for determination of design wind loads. NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R29 for FL2533-R28 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 29: 04/14/2022 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 6 of 70 TABLE 1A: WOOD DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER Sys. No. Deck (Note 1) Base Insulation Top Insulation Primer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply SELF-ADHERING SYSTEMS: W-1 Min. 15/32-inch APA rated CDX plywood, 24-inch span Min. 1.5-inch ACFoam II or H-Shield M-OSFA or M-PG1 (Optional) Additional layer(s) of base insulation and/or min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board. M-OSFA or M-PG1 FlintPrime QD SBS-SA (Optional) SBS- SA SBS-SA -60.0 W-2 Min. 15/32-inch APA rated CDX plywood, 24-inch span, blocked 48-inch o.c. Min. 1.5-inch ACFoam II or H-Shield M-OSFA or M-PG1, 6- inch o.c. (Optional) Additional layer(s) of base insulation and/or min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board. M-OSFA or M-PG1, 6- inch o.c. FlintPrime QD SBS-SA (Optional) SBS- SA SBS-SA -97.5 HYBRID SYSTEMS: W-3 Min. 15/32-inch APA rated CDX plywood, 24-inch span Min. 1.5-inch ACFoam II or H-Shield M-OSFA or M-PG1 (Optional) Additional layer(s) of base insulation and/or min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board. M-OSFA or M-PG1 None SBS-SA-H (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -60.0 W-4 Min. 15/32-inch APA rated CDX plywood, 24-inch span, blocked 48-inch o.c. Min. 1.5-inch ACFoam II or H-Shield M-OSFA or M-PG1, 6- inch o.c. (Optional) Additional layer(s) of base insulation and/or min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board. M-OSFA or M-PG1, 6- inch o.c. None SBS-SA-H (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -97.5 CONVENTIONAL SYSTEMS: W-5 Min. 15/32-inch APA rated CDX plywood, 24-inch span Min. 1.5-inch ACFoam II or H-Shield M-OSFA or M-PG1 Optional additional layers of base insulation, followed by min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board M-OSFA or M-PG1 None BP-AA, SBS- AA, SBS-TA or APP-TA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -60.0 W-6 Min. 15/32-inch APA rated CDX plywood, 24-inch span, blocked 48-inch o.c. Min. 1.5-inch ACFoam II or H-Shield M-OSFA or M-PG1, 6- inch o.c. Optional additional layers of base insulation, followed by min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board. M-OSFA or M-PG1, 6- inch o.c. None BP-AA, SBS- AA, SBS-TA or APP-TA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -97.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R29 for FL2533-R28 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 29: 04/14/2022 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 7 of 70 TABLE 1B: WOOD DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER Sys. No. Deck (Note 1) Anchor Sheet Base Insulation Top Insulation Primer Roof Cover (Note 15) MDP (psf) Type Fasteners Attach Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply SELF-ADHERING SYSTEMS: W-7 Min. 19/32- inch plywood, 24-inch span Glasbase Base Sheet, All Weather/Empire Base Sheet, Flintlastic Base 20, Poly SMS, Ultra Poly SMS or Flintglas MS Cap (inverted) 32 ga., 1-5/8- inch dia. tin caps with 11 ga. annular ring shank nails 9-inch o.c. in 4- inch lap and 12- inch o.c. in two (2), equally spaced, staggered center rows Min. 1.5-inch ACFoam II, ENRGY 3, H- Shield or Multi- Max FA3 hot asphalt Min. 0.25- inch DensDeck hot asphalt FlintPrime QD SBS-SA (Optional) SBS-SA SBS-SA -45.0* W-8 Min. 19/32- inch plywood, 24-inch span Glasbase Base Sheet, All Weather/Empire Base Sheet, Poly SMS or Ultra Poly SMS 32 ga., 1-5/8- inch dia. tin caps with 11 ga. annular ring shank nails 8-inch o.c. in 3- inch lap and 8- inch o.c. in three (3), equally spaced, staggered center rows Min. 1.5-inch ACFoam II, ENRGY 3, H- Shield or Multi- Max FA3 hot asphalt full coverage or M- OSFA, Insta Stik, OB500, Polyset BM or Polyset CRA, 4-inch o.c. Min. 0.25- inch DensDeck hot asphalt full coverage or M- OSFA, Insta Stik, OB500, Polyset BM or Polyset CRA, 6-inch o.c. FlintPrime QD SBS-SA (Optional) SBS-SA SBS-SA -52.5 W-9 Min. 19/32- inch plywood, 24-inch span Flintglas MS Cap (inverted) 32 ga., 1-5/8- inch dia. tin caps with 11 ga. annular ring shank nails 8-inch o.c. in 3- inch lap and 8- inch o.c. in three (3), equally spaced, staggered center rows Min. 1.5-inch ACFoam II, ENRGY 3, H- Shield or Multi- Max FA3 hot asphalt Min. 0.25- inch DensDeck hot asphalt FlintPrime QD SBS-SA (Optional) SBS-SA SBS-SA -52.5 W-10 Min. 19/32- inch plywood, 24-inch span Glasbase Base Sheet, All Weather/Empire Base Sheet, Poly SMS or Ultra Poly SMS 32 ga., 1-5/8- inch dia. tin caps with 11 ga. annular ring shank nails 8-inch o.c. in 3- inch lap and 8- inch o.c. in three (3), equally spaced, staggered center rows (Optional) Min. 1.5-inch ACFoam II, ENRGY 3, H- Shield or Multi- Max FA3 hot asphalt full coverage or M- OSFA, Insta Stik, OB500, Polyset BM or Polyset CRA, 4-inch o.c. Min. 0.25- inch SECUROCK Gypsum- Fiber Roof Board hot asphalt full coverage or M- OSFA, Insta Stik, OB500, Polyset BM or Polyset CRA, 6-inch o.c. FlintPrime QD SBS-SA (Optional) SBS-SA SBS-SA -60.0 W-11 Min. 19/32- inch plywood, 24-inch span Flintglas MS Cap (inverted) 32 ga., 1-5/8- inch dia. tin caps with 11 ga. annular ring shank nails 8-inch o.c. in 3- inch lap and 8- inch o.c. in three (3), equally spaced, staggered center rows (Optional) Min. 1.5-inch ACFoam II, ENRGY 3, H- Shield or Multi- Max FA3 hot asphalt Min. 0.25- inch SECUROCK Gypsum- Fiber Roof Board hot asphalt FlintPrime QD SBS-SA (Optional) SBS-SA SBS-SA -60.0 HYBRID SYSTEMS: W-12 Min. 19/32- inch plywood, 24-inch span Glasbase Base Sheet, All Weather/Empire Base Sheet, Flintlastic Base 20, Poly SMS, Ultra Poly SMS or Flintglas MS Cap (inverted) 32 ga., 1-5/8- inch dia. tin caps with 11 ga. annular ring shank nails 9-inch o.c. in 4- inch lap and 12- inch o.c. in two (2), equally spaced, staggered center rows Min. 1.5-inch ACFoam II, ENRGY 3, H- Shield or Multi- Max FA3 hot asphalt None N/A None SBS-SA-H (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP- TA -45.0* NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R29 for FL2533-R28 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 29: 04/14/2022 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 8 of 70 TABLE 1B: WOOD DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER Sys. No. Deck (Note 1) Anchor Sheet Base Insulation Top Insulation Primer Roof Cover (Note 15) MDP (psf) Type Fasteners Attach Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply W-13 Min. 19/32- inch plywood at max. 24- inch Glasbase Base Sheet or Flintglas MS Cap (inverted) 32 ga., 1-5/8- inch dia. tin caps with 11 ga. annular ring shank nails 8-inch o.c. in 3- inch lap and 8- inch o.c. in three (3), equally spaced, staggered center rows Min. 1.5-inch ACFoam II, ENRGY 3, H- Shield or Multi- Max FA3 hot asphalt None N/A None SBS-SA-H (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP- TA -60.0 CONVENTIONAL SYSTEMS: W-14 Min. 19/32- inch plywood, 24-inch span Glasbase Base Sheet, All Weather/Empire Base Sheet, Flintlastic Base 20, Poly SMS, Ultra Poly SMS or Flintglas MS Cap (inverted) 32 ga., 1-5/8- inch dia. tin caps with 11 ga. annular ring shank nails 9-inch o.c. in 4- inch lap and 12- inch o.c. in two (2), equally spaced, staggered center rows Min. 1.5-inch ACFoam II, ENRGY 3, H- Shield or Multi- Max FA3 hot asphalt Min. 0.25- inch DensDeck hot asphalt FlintPrime QD BP-AA, SBS-AA, SBS-TA or APP-TA (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP- TA -45.0* W-15 Min. 19/32- inch plywood, 24-inch span Glasbase Base Sheet, All Weather/Empire Base Sheet, Poly SMS or Ultra Poly SMS 32 ga., 1-5/8- inch dia. tin caps with 11 ga. annular ring shank nails 8-inch o.c. in 3- inch lap and 8- inch o.c. in three (3), equally spaced, staggered center rows Min. 1.5-inch ACFoam II, ENRGY 3, H- Shield or Multi- Max FA3 hot asphalt full coverage or M- OSFA, Insta Stik, OB500, Polyset BM or Polyset CRA, 4-inch o.c. Min. 0.25- inch DensDeck hot asphalt full coverage or M- OSFA, Insta Stik, OB500, Polyset BM or Polyset CRA, 6-inch o.c. FlintPrime QD BP-AA, SBS-AA, SBS-TA or APP-TA (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP- TA -52.5 W-16 Min. 19/32- inch plywood, 24-inch span Glasbase Base Sheet, All Weather/Empire Base Sheet, Poly SMS or Ultra Poly SMS 32 ga., 1-5/8- inch dia. tin caps with 11 ga. annular ring shank nails 8-inch o.c. in 3- inch lap and 8- inch o.c. in three (3), equally spaced, staggered center rows (Optional) Min. 1.5-inch ACFoam II, ENRGY 3, H- Shield or Multi- Max FA3 hot asphalt full coverage or M- OSFA, Insta Stik, OB500, Polyset BM or Polyset CRA, 4-inch o.c. Min. 0.25- inch SECUROCK Gypsum- Fiber Roof Board hot asphalt full coverage or M- OSFA, Insta Stik, OB500, Polyset BM or Polyset CRA, 6-inch o.c. None BP-AA, SBS-AA, SBS-TA or APP-TA (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP- TA -60.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R29 for FL2533-R28 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 29: 04/14/2022 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 9 of 70 TABLE 1C: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE B-1: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Fasteners Attach Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply HYBRID SYSTEMS: W-17 Min. 15/32-inch plywood, 24- inch span Min. 1.5-inch ACFoam II or H- Shield Trufast #12 DP or #14 HD with Trufast 3”Metal Insulation Plates 1 per 1.3 ft2 Min. 1.5-inch ACFoam II or H-Shield hot asphalt, M-OSFA, M-PG1 Insta Stik, OB500 SBS-SA-H (Optional) APP-TA APP-TA -67.5 CONVENTIONAL SYSTEMS: W-18 Min. 23/32-inch plywood, 24- inch span Min. 1.5-inch ACFoam II, ENRGY 3 or H-Shield Note 2 1 per 2.0 ft2 Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation, min. 0.75-inch FescoBoard (homogeneous) hot asphalt BP-AA or SBS-AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA or APP-TA -45.0* W-19 Min. 23/32-inch plywood, 24- inch span Min. 1.5-inch ACFoam II, ENRGY 3 or H-Shield Note 2 1 per 2.0 ft2 Min. 0.25-inch DensDeck, DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board hot asphalt BP-AA, SBS- AA, SBS-TA or APP-TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA or APP-TA -45.0* W-20 Min. 15/32-inch plywood, 24- inch span Min. 1.5-inch ACFoam II or H- Shield Trufast #12 DP or #14 HD with Trufast 3”Metal Insulation Plates 1 per 1.3 ft2 Optional additional layer(s) of base insulation followed by Min. 0.25- inch SECUROCK Gypsum-Fiber Roof board hot asphalt, M-OSFA, M-PG1, Insta Stik, OB500 APP-TA (Optional) APP-TA APP-TA -90.0 TABLE 1D: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer Top Insulation Layer Primer Roof Cover (Note 15) MDP (psf) Type Fasteners Attach Base Ply Ply Cap Ply SELF-ADHERING SYSTEMS: W-21 Min. 15/32-inch plywood, 24-inch span (Optional) One or more layers, any combination, loose laid Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Trufast #12 DP or #14 HD with Trufast 3” Metal Insulation Plate 1 per 3.2 ft2 None SBS-SA (Optional) SBS- SA SBS-SA -30.0* W-22 Min. 19/32-inch plywood, 24-inch span (Optional) One or more layers, any combination, loose laid Min. 0.25-inch DensDeck Note 2 1 per 1.3 ft2 FlintPrime QD SBS-SA (Optional) SBS- SA SBS-SA -45.0 W-23 Min. 19/32-inch plywood, 24-inch span (Optional) One or more layers, any combination, loose laid Min. 3/8-inch SECUROCK Gypsum-Fiber Roof Board Trufast #12 DP or #14 HD with Trufast 3” Metal Insulation Plate 1 per 2.7 ft2 None SBS-SA (Optional) SBS- SA SBS-SA -45.0* W-24 Min. 19/32-inch plywood, 24-inch span (Optional) One or more layers, any combination, loose laid Min. 1.5-inch ACFoam II, ENRGY 3, H-Shield or Multi- Max FA3 Trufast #12 DP or #14 HD with Trufast 3” Metal Insulation Plate 1 per 2.0 ft2 FlintPrime QD SBS-SA (Optional) SBS- SA SBS-SA -45.0* W-25 Min. 15/32-inch plywood, 24-inch span (Optional) One or more layers, any combination, loose laid Min. 1.5-inch ACFoam II Trufast #14 HD with Trufast 3” Metal Insulation Plate 1 per 1.6 ft2 FlintPrime QD SBS-SA (Optional) SBS- SA SBS-SA -52.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R29 for FL2533-R28 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 29: 04/14/2022 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 10 of 70 TABLE 1D: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer Top Insulation Layer Primer Roof Cover (Note 15) MDP (psf) Type Fasteners Attach Base Ply Ply Cap Ply W-26 Min. 19/32-inch plywood, 24-inch span (Optional) One or more layers, any combination, loose laid Min. 1.5-inch ACFoam II, ENRGY 3, H-Shield or Multi- Max FA3 Note 2 1 per 1.45 ft2 FlintPrime QD SBS-SA (Optional) SBS- SA SBS-SA -60.0 HYBRID SYSTEMS: W-27 Min. 15/32-inch plywood, 24-inch span (Optional) One or more layers, any combination, loose laid Min. 0.25-inch DensDeck, DensDeck Prime Trufast #12 DP or #14 HD with Trufast 3” Metal Insulation Plate 1 per 2.0 ft2 None SBS-SA- H (Optional) BP- AA, SBS-AA, SBS-TA or APP- TA SBS-AA or APP-TA -30.0* W-28 Min. 15/32-inch plywood, 24-inch span (Optional) One or more layers, any combination, loose laid Min. 1.5-inch ACFoam II Trufast #14 HD with Trufast 3” Metal Insulation Plate 1 per 1.6 ft2 None SBS-SA- H (Optional) SBS- TA or APP-TA APP-TA -52.5 W-29 Min. 15/32-inch plywood, 24-inch span (Optional) One or more layers, any combination, loose laid Min. 1.5-inch ACFoam II, ENRGY 3 or Multi-Max FA3 Note 2 1 per 1.3 ft2 None SBS-SA- H (Optional) BP- AA or SBS-AA SBS-AA -52.5 W-30 Min. 19/32-inch plywood, 24-inch span (Optional) One or more layers, any combination, loose laid Min. 1.5-inch ACFoam II or H- Shield Note 2 1 per 1.45 ft2 None SBS-SA- H (Optional) BP- AA, SBS-AA, SBS-TA or APP- TA SBS-AA or APP-TA -60.0 W-31 Min. 15/32-inch plywood, 24-inch span (Optional) Min. 1.5-inch, One or more layers, any combination, loose laid Min. 1.5-inch ACFoam II or H- Shield Trufast #12 DP or #14 HD with Trufast 3” Metal Insulation Plate 1 per 1.3 ft2 None SBS-SA- H (Optional) SBS- AA, SBS-TA or APP-TA SBS-AA or APP-TA -75.0 W-32 Min. 19/32-inch plywood, 24-inch span (Optional) One or more layers, any combination, loose laid Min. 1.5-inch ACFoam II, ENRGY 3 or Multi-Max FA3 Note 2 1 per 1.3 ft2 None SBS-SA- H (Optional) SBS- TA or APP-TA APP-TA -82.5 CONVENTIONAL SYSTEMS: W-33 Min. 23/32-inch plywood, 24-inch span (Optional) One or more layers, any combination, loose laid Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation, min. 0.75-inch FescoBoard (homogeneous) Note 2 1 per 2.0 ft2 None BP-AA or SBS-AA (Optional) BP- AA, SBS-AA, SBS-TA or APP- TA SBS-AA or APP-TA -45.0* W-34 Min. 15/32-inch plywood, 24-inch span (Optional) One or more layers, any combination, loose laid Min. 0.25-inch DensDeck, DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Trufast #12 DP or #14 HD with Trufast 3” Metal Insulation Plate 1 per 2.0 ft2 None BP-AA, SBS-AA, SBS-TA or APP- TA (Optional) BP- AA, SBS-AA, SBS-TA or APP- TA SBS-AA or APP-TA -45.0* W-35 Min. 15/32-inch plywood, 24-inch span (Optional for Recover) Min. 1.5-inch, One or more layers, any combination, loose laid Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Trufast #12 DP or #14 HD with Trufast 3” Metal Insulation Plate 1 per 1.45 ft2 None APP-TA (Optional) APP- TA APP-TA -60.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R29 for FL2533-R28 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 29: 04/14/2022 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 11 of 70 TABLE 1D: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer Top Insulation Layer Primer Roof Cover (Note 15) MDP (psf) Type Fasteners Attach Base Ply Ply Cap Ply W-36 Min. 19/32-inch plywood, 24-inch span Min. 2-inch ACFoam II, ENRGY 3 or H-Shield, loose laid. Min. 0.5-inch SECUROCK Gypsum-Fiber Roof Board Trufast #12 DP or #14 HD with Trufast 3” Metal Insulation Plate 1 per 1.8 ft2 None BP-AA, SBS-AA, SBS-TA or APP- TA (Optional) BP- AA, SBS-AA, SBS-TA or APP- TA SBS-AA or APP-TA -60.0 W-37 Min. 15/32-inch plywood, 24-inch span (Optional for Recover) Min. 1.5-inch, One or more layers, any combination, loose laid Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Trufast #12 DP or #14 HD with Trufast 3” Metal Insulation Plate 1 per 1.3 ft2 None APP-TA (Optional) APP- TA APP-TA -67.5 TABLE 1E: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE D-2: INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Insulation Layer(s) (Note 13) Base Sheet Primer Roof Cover (Note 15) MDP (psf) Type Attach Type Fasteners Attach Base Ply Cap Ply SELF-ADHERING SYSTEMS: W-38 Min. 19/32- inch plywood, 24-inch span Min. 1.5-inch, One or more layers, any combination Prelim. Attach Flintlastic SA NailBase Note 2 8-inch o.c. at min. 3-inch lap and 8-inch o.c. in two (2), equally spaced, staggered center rows FlintPrime QD at stress plates (Optional) SBS-SA SBS-SA -82.5* W-39 Min. 15/32- inch plywood, 24-inch span Min. 1.5-inch, One or more layers, any combination Prelim. Attach Flintlastic SA NailBase OMG #14 HD with OMG 3 in. Round Metal Plate or Trufast #12 DP or #14 HD with Trufast 3” Metal Insulation Plate 6-inch o.c. at min. 2-inch lap and 6-inch o.c. in three (3), equally spaced, staggered center rows FlintPrime QD at stress plates (Optional) SBS-SA SBS-SA -97.5* W-40 Min. 15/32- inch plywood, 24-inch span Min. 1.5-inch, One or more layers, any combination Prelim. Attach Flintlastic SA NailBase OMG #14 HD with OMG 3 in. Round Metal Plate or Trufast #12 DP or #14 HD with Trufast 3” Metal Insulation Plate 6-inch o.c. at min. 2-inch lap and 6-inch o.c. in four (4), equally spaced, staggered center rows FlintPrime QD at stress plates (Optional) SBS-SA SBS-SA -127.5* HYBRID SYSTEMS: W-41 Min. 15/32- inch plywood, 24-inch span Min. 1.5-inch, One or more layers, any combination Prelim. Attach Glasbase Base Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet OMG #14 HD with OMG 3 in. Round Metal Plate or Trufast #12 DP or #14 HD with Trufast 3” Metal Insulation Plate 6-inch o.c. at 4-inch lap and 6- inch o.c. in three (3), equally spaced, staggered center rows FlintPrime QD at stress plates SBS-SA-H SBS-AA or APP-TA -97.5 W-42 Min. 19/32- inch plywood, 24-inch span Min. 1.5-inch, One or more layers, any combination Prelim. Attach Glasbase Base Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet Note 2 7-inch o.c. at 3-inch lap and 7- inch o.c. in three (3), equally spaced, staggered center rows None SBS-SA-H SBS-AA or APP-TA -105.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R29 for FL2533-R28 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 29: 04/14/2022 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 12 of 70 TABLE 1E: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE D-2: INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Insulation Layer(s) (Note 13) Base Sheet Primer Roof Cover (Note 15) MDP (psf) Type Attach Type Fasteners Attach Base Ply Cap Ply W-43 Min. 15/32- inch plywood, 24-inch span Min. 1.5-inch, One or more layers, any combination Prelim. Attach Glasbase Base Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet OMG #14 HD with OMG 3 in. Round Metal Plate or Trufast #12 DP or #14 HD with Trufast 3” Metal Insulation Plate 6-inch o.c. at 4-inch lap and 6- inch o.c. in four (4), equally spaced, staggered center rows FlintPrime QD at stress plates SBS-SA-H SBS-AA or APP-TA -127.5 CONVENTIONAL SYSTEMS: W-44 Min. 23/32- inch plywood, 24-inch span Min. 1.5-inch, One or more layers, any combination Prelim. Attach Glasbase Base Sheet, All Weather/Empire Base Sheet, Flintlastic Base 20 or Flintglas MS Cap (inverted) Note 2 12-inch o.c. at 4-inch lap and 36-inch o.c. in two (2), equally spaced, staggered center rows None BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP-TA -30.0* W-45 Min. 23/32- inch plywood, 24-inch span Min. 1.5-inch, One or more layers, any combination Prelim. Attach Glasbase Base Sheet, All Weather/Empire Base Sheet, Flintlastic Base 20 or Flintglas MS Cap (inverted) Note 2 12-inch o.c. at 4-inch lap and 24-inch o.c. in two (2), equally spaced, staggered center rows None BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP-TA -45.0* W-46 Min. 23/32- inch plywood, 24-inch span Min. 1.5-inch, One or more layers, any combination Prelim. Attach Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet Note 2 12-inch o.c. at 4-inch lap and 36-inch o.c. in two (2), equally spaced, staggered center rows None BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP-TA -45.0* W-47 Min. 15/32- inch plywood, 24-inch span Min. 1.5-inch, One or more layers, any combination Prelim. Attach Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet or Flintglas MS Cap (inverted) OMG #14 HD with OMG 3 in. Round Metal Plate or Trufast #12 DP or #14 HD with Trufast 3” Metal Insulation Plate 6-inch o.c. at 4-inch lap and 6- inch o.c. in three (3), equally spaced, staggered center rows. None (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP-TA -97.5 W-48 Min. 15/32- inch plywood, 24-inch span Min. 1.5-inch, One or more layers, any combination Prelim. Attach Flintlastic APP Base T OMG #14 HD with OMG 3 in. Round Metal Plates 6-inch o.c. at 4-inch lap and 6- inch o.c. in three (3), equally spaced, staggered center rows. None APP-TA APP-TA -97.5 W-49 Min. 15/32- inch plywood, 24-inch span One or more layers, any thickness or combination Prelim. Attach Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet or Flintglas MS Cap (inverted) Trufast #14 HD with Trufast 3” Metal Insulation Plate 8-inch o.c. at 4-inch lap and 8- inch o.c. at three (3) equally spaced, staggered center rows None (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP-TA -97.5 W-50 Min. 19/32- inch plywood, 24-inch span Min. 1.5-inch, One or more layers, any combination Prelim. Attach Glasbase Base Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet or Flintglas MS Cap (inverted) Note 2 7-inch o.c. at 3-inch lap and 7- inch o.c. in three (3), equally spaced, staggered center rows None BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP-TA -105.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R29 for FL2533-R28 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 29: 04/14/2022 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 13 of 70 TABLE 1E: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE D-2: INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Insulation Layer(s) (Note 13) Base Sheet Primer Roof Cover (Note 15) MDP (psf) Type Attach Type Fasteners Attach Base Ply Cap Ply W-51 Min. 19/32- inch plywood, 24-inch span Min. 1.5-inch, One or more layers, any combination Prelim. Attach Flintlastic APP Base T Dekfast DF-#14-PH3 with PLT-H-2-7/8 or OMG #14 HD with OMG 3 in. Round Metal Plate 7-inch o.c. at 3-inch lap and 7- inch o.c. in three (3), equally spaced, staggered center rows None APP-TA APP-TA -105.0 W-52 Min. 15/32- inch plywood, 24-inch span Min. 1.5-inch, One or more layers, any combination Prelim. Attach Glasbase Base Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet or Flintglas MS Cap (inverted) OMG #14 HD with OMG 3 in. Round Metal Plate or Trufast #12 DP or #14 HD with Trufast 3” Metal Insulation Plate 6-inch o.c. at 4-inch lap and 6- inch o.c. in four (4), equally spaced, staggered center rows. None (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP-TA -127.5 W-53 Min. 15/32- inch plywood, 24-inch span Min. 1.5-inch, One or more layers, any combination Prelim. Attach Flintlastic APP Base T OMG #14 HD with OMG 3 in. Round Metal Plates 6-inch o.c. at 4-inch lap and 6- inch o.c. in four (4), equally spaced, staggered center rows. None APP-TA APP-TA -127.5 COLD-APPLIED SYSTEMS: W-54 Min. 15/32- inch plywood, 24-inch span Min. 1-inch, One or more layers, any combination Loose- laid Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet or Flintglas MS Cap (inverted) Trufast #12 DP or #14 HD with Trufast 3” Metal Insulation Plate 8-inch o.c. at 4-inch lap and 8- inch o.c. in three (3), equally spaced, staggered center rows None (Optional) SBS-CA1 SBS-CA1 -52.5 TABLE 1F: WOOD DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE E-2: NON-INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Base Sheet Primer Roof Cover (Note 15) MDP (psf) Base Fasteners Attach Base Ply Cap Ply SELF-ADHERING SYSTEMS: W-55 Min. 15/32-inch plywood, 24-inch span Flintlastic SA NailBase Simplex MAXX Cap 9-inch o.c. at min. 3-inch lap and 12-inch o.c. in two (2), equally spaced, staggered center rows FlintPrime QD at stress plates (Optional) SBS-SA SBS-SA -45.0* W-56 Min. 15/32-inch plywood, 24-inch span Flintlastic SA NailBase Min. 1-inch long, 12 ga. Simplex Metal Cap Nails 6-inch o.c. at min. 2-inch lap and 6-inch o.c. in four (4), equally spaced, staggered center rows None (Optional) SBS-SA SBS-SA -52.5 W-57 Min. 19/32-inch plywood, 24-inch span Flintlastic SA NailBase 32 ga., 1-5/8-inch dia. tin caps with 11 ga. annular ring shank nails 8-inch o.c. at min. 2-inch lap and 8-inch o.c. in three (3), equally spaced, staggered center rows None (Optional) SBS-SA SBS-SA -52.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R29 for FL2533-R28 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 29: 04/14/2022 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 14 of 70 TABLE 1F: WOOD DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE E-2: NON-INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Base Sheet Primer Roof Cover (Note 15) MDP (psf) Base Fasteners Attach Base Ply Cap Ply W-58 APA rated, min. 7/16 CAT, 0.418 in., Exposure 1, OSB, 24-inch span Flintlastic SA NailBase Simplex MAXX Cap 8-inch o.c. at min. 3-inch lap and 8-inch o.c. in three (3), equally spaced, staggered center rows FlintPrime QD at stress plates (Optional) Flintlastic SA Mid Ply, self- adhering SBS-SA -52.5 W-59 Min. 19/32-inch plywood, 24-inch span Flintlastic SA NailBase 32 ga., 1-5/8-inch dia. tin caps with 11 ga. annular ring shank nails 8-inch o.c. at min. 2-inch lap and 8-inch o.c. in three (3), equally spaced, staggered center rows None (Optional) SBS-SA SBS-SA -60.0 W-60 Min. 15/32-inch plywood, 24-inch span Flintlastic SA NailBase Simplex MAXX Cap 8-inch o.c. at min. 3-inch lap and 8-inch o.c. in three (3), equally spaced, staggered center rows FlintPrime QD at stress plates (Optional) SBS-SA SBS-SA -67.5 W-61 Min. 19/32-inch plywood, 24-inch span Flintlastic SA NailBase 32 ga., 1-5/8-inch dia. tin caps with 11 ga. annular ring shank nails 6-inch o.c. at min. 2-inch lap and 6-inch o.c. in four (4), equally spaced, staggered center rows None (Optional) SBS-SA SBS-SA -75.0 W-62 Min. 15/32-inch plywood, 24-inch span Flintlastic SA NailBase Cap nails: 1-inch diameter, 0.032- inch metal cap with 0.120" shank diameter, annular ring shank nails 7-inch o.c. at min. 4-inch laps and 7-inch o.c. in five (5), equally spaced, staggered center rows None (Optional) SBS-SA SBS-SA -75.0 W-63 Min. 19/32-inch plywood, 24-inch span Flintlastic SA NailBase 32 ga., 1-5/8-inch dia. tin caps with 11 ga. annular ring shank nails 4-inch o.c. at min. 2-inch lap and 4-inch o.c. in four (4), equally spaced, staggered center rows None (Optional) SBS-SA SBS-SA -105.0 HYBRID SYSTEMS: W-64 Min. 19/32-inch plywood, 24-inch span Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet 32 ga., 1-5/8-inch dia. tin caps with 11 ga. annular ring shank nails 9-inch o.c. at 4-inch lap and 12-inch o.c. in two (2), equally spaced, staggered center rows None SBS-SA-H SBS-AA or APP-TA -45.0* W-65 Min. 15/32-inch plywood, 24-inch span Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet Min. 1-inch long, 12 ga. Simplex Metal Cap Nails 6-inch o.c. at 3-inch lap and 6-inch o.c. in four (4), equally spaced, staggered center rows None SBS-SA-H SBS-AA or APP-TA -52.5 W-66 Min. 19/32-inch plywood, 24-inch span Glasbase Base Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet 32 ga., 1-5/8-inch dia. tin caps with 11 ga. annular ring shank nails 8-inch o.c. at 4-inch lap and 8-inch o.c. in three (3), equally spaced, staggered center rows None SBS-SA-H SBS-AA or APP-TA -52.5 W-67 Min. 19/32-inch plywood, 24-inch span Glasbase Base Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet 32 ga., 1-5/8-inch dia. tin caps with 11 ga. annular ring shank nails 8-inch o.c. at 4-inch lap and 8-inch o.c. in three (3), equally spaced, staggered center rows None SBS-SA-H SBS-AA or APP-TA -60.0 W-68 Min. 19/32-inch plywood, 24-inch span Glasbase Base Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet 32 ga., 1-5/8-inch dia. tin caps with 11 ga. annular ring shank nails 6-inch o.c. at 4-inch lap and 6-inch o.c. in four (4), equally spaced, staggered center rows None SBS-SA-H SBS-AA or APP-TA -82.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R29 for FL2533-R28 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 29: 04/14/2022 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 15 of 70 TABLE 1F: WOOD DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE E-2: NON-INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Base Sheet Primer Roof Cover (Note 15) MDP (psf) Base Fasteners Attach Base Ply Cap Ply W-69 Min. 19/32-inch plywood, 24-inch span Glasbase Base Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet 32 ga., 1-5/8-inch dia. tin caps with 11 ga. annular ring shank nails 4-inch o.c. at 3-inch lap and 4-inch o.c. in four (4), equally spaced, staggered center rows None SBS-SA-H SBS-AA or APP-TA -105.0 CONVENTIONAL SYSTEMS: W-70 Min. 19/32-inch plywood, 24-inch span Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet or Flintglas MS Cap (inverted) 32 ga., 1-5/8-inch dia. tin caps with 11 ga. annular ring shank nails 9-inch o.c. at 4-inch lap and 12-inch o.c. in two (2), equally spaced, staggered center rows None BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP-TA -45.0* W-71 Min. 15/32-inch plywood, 24-inch span Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet, Flintlastic Poly SMS Base Sheet or Flintglas MS Cap (inverted) Simplex MAXX Cap 9-inch o.c. at 2-inch lap and 18-inch o.c. in two (2), equally spaced, staggered center rows None (Optional) BP- AA, SBS-AA, SBS-TA or APP-TA SBS-AA or APP-TA -45.0* W-72 Min. 15/32-inch plywood, 24-inch span Flintlastic APP Base T Simplex MAXX Cap 9-inch o.c. at 2-inch lap and 18-inch o.c. in two (2), equally spaced, staggered center rows None (Optional) APP-TA APP-TA -45.0* W-73 Min. 15/32-inch plywood, 24-inch span Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet or Flintglas MS Cap (inverted) Min. 1-inch long, 12 ga. Simplex Metal Cap Nails 6-inch o.c. at 3-inch lap and 6-inch o.c. in four (4), equally spaced, staggered center rows None (Optional) BP- AA, SBS-AA, SBS-TA or APP-TA SBS-AA or APP-TA -52.5 W-74 Min. 19/32-inch plywood, 24-inch span Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet or Flintglas MS Cap (inverted) 32 ga., 1-5/8-inch dia. tin caps with 11 ga. annular ring shank nails 8-inch o.c. at 4-inch lap and 8-inch o.c. in three (3), equally spaced, staggered center rows None BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP-TA -52.5 W-75 Min. 15/32-inch plywood, 24-inch span Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet, Flintlastic Poly SMS Base Sheet or Flintglas MS Cap (inverted) Simplex MAXX Cap 9-inch o.c. at 2-inch lap and 12-inch o.c. in two (2), equally spaced, staggered center rows None (Optional) BP- AA, SBS-AA, SBS-TA or APP-TA SBS-AA or APP-TA -52.5 W-76 Min. 15/32-inch plywood, 24-inch span Flintlastic APP Base T Simplex MAXX Cap 9-inch o.c. at 2-inch lap and 12-inch o.c. in two (2), equally spaced, staggered center rows None (Optional) APP-TA APP-TA -52.5 W-77 Min. 19/32-inch plywood, 24-inch span Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet or Flintglas MS Cap (inverted) 32 ga., 1-5/8-inch dia. tin caps with 11 ga. annular ring shank nails 8-inch o.c. at 4-inch lap and 8-inch o.c. in three (3), equally spaced, staggered center rows None BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP-TA -60.0 W-78 Min. 15/32-inch plywood, 24-inch span Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet or Flintglas MS Cap (inverted) Cap nails: 1-inch diameter, 0.032- inch metal cap with 0.120-inch shank diameter, annular ring shank nails. 6-inch o.c. at 4-inch lap and 6-inch o.c. at five (5) equally spaced, staggered center rows None (Optional) BP- AA, SBS-AA or SBS-TA SBS-AA -67.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R29 for FL2533-R28 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 29: 04/14/2022 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 16 of 70 TABLE 1F: WOOD DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE E-2: NON-INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Base Sheet Primer Roof Cover (Note 15) MDP (psf) Base Fasteners Attach Base Ply Cap Ply W-79 Min. 19/32-inch plywood, 24-inch span Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet or Flintglas MS Cap (inverted) 32 ga., 1-5/8-inch dia. tin caps with 11 ga. annular ring shank nails 6-inch o.c. at 4-inch lap and 6-inch o.c. in four (4), equally spaced, staggered center rows None BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP-TA -82.5 W-80 Min. 15/32-inch plywood, 24-inch span Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet, Flintlastic Poly SMS Base Sheet or Flintglas MS Cap (inverted) Simplex MAXX Cap 6-inch o.c. at 2-inch lap and 6-inch o.c. in two (2), equally spaced, staggered center rows None (Optional) BP- AA, SBS-AA, SBS-TA or APP-TA SBS-AA or APP-TA -90.0 W-81 Min. 15/32-inch plywood, 24-inch span Flintlastic APP Base T Simplex MAXX Cap 6-inch o.c. at 2-inch lap and 6-inch o.c. in two (2), equally spaced, staggered center rows None (Optional) APP-TA APP-TA -90.0 W-82 Min. 19/32-inch plywood, 24-inch span Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet or Flintglas MS Cap (inverted) 32 ga., 1-5/8-inch dia. tin caps with 11 ga. annular ring shank nails 4-inch o.c. at 3-inch lap and 4-inch o.c. in four (4), equally spaced, staggered center rows None BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP-TA -105.0 W-83 Min. 15/32-inch plywood, 24-inch span Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet, Flintlastic Poly SMS Base Sheet or Flintglas MS Cap (inverted) Simplex MAXX Cap 6-inch o.c. at 2-inch lap and 6-inch o.c. in three (3), equally spaced, staggered center rows None (Optional) BP- AA, SBS-AA, SBS-TA or APP-TA SBS-AA or APP-TA -105.0 W-84 Min. 15/32-inch plywood, 24-inch span Flintlastic APP Base T Simplex MAXX Cap 6-inch o.c. at 2-inch lap and 6-inch o.c. in three (3), equally spaced, staggered center rows None (Optional) APP-TA APP-TA -105.0 TABLE 1G: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE E-2: NON-INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Base Sheet Primer Roof Cover (Note 15) MDP (psf) Base Fasteners Attach Base Ply Cap Ply SELF-ADHERING SYSTEMS: W-85 APA rated, min. 7/16 CAT, 0.418 in., Exposure 1, OSB, 24-inch span Flintlastic SA NailBase Trufast Versa Fasteners & Plates, two (2) screws per plate at 180° from each other* 9-inch o.c. at min. 3-inch lap and 12-inch o.c. in two (2), equally spaced, staggered center rows FlintPrime QD at stress plates (Optional) Flintlastic SA Mid Ply, self- adhering SBS-SA -60.0* Note: *For re-roof (tear-off) or recover applications, field withdrawal resistance testing (Note 11) shall yield minimum 109 lbf. Additional Versa-Fast Fasteners within each Versa-Fast Plate may be utilized to produce minimum withdrawal resistance. For recover installations, screws shall be of sufficient length for minimum 1” penetration through OSB sheathing. W-86 Min. 19/32-inch plywood, 24-inch span Flintlastic SA NailBase Note 2 8-inch o.c. at min. 3-inch lap and 8-inch o.c. in two (2), equally spaced, staggered center rows FlintPrime QD at stress plates (Optional) SBS-SA SBS-SA -82.5* NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R29 for FL2533-R28 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 29: 04/14/2022 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 17 of 70 TABLE 1G: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE E-2: NON-INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Base Sheet Primer Roof Cover (Note 15) MDP (psf) Base Fasteners Attach Base Ply Cap Ply W-87 Min. 15/32-inch plywood, 24-inch span Flintlastic SA NailBase OMG #14 HD with OMG 3 in. Round Metal Plate or Trufast #12 DP or #14 HD with Trufast 3” Metal Insulation Plate 6-inch o.c. at min. 2-inch lap and 6-inch o.c. in three (3), equally spaced, staggered center rows FlintPrime QD at stress plates (Optional) SBS-SA SBS-SA -97.5* W-88 Min. 15/32-inch plywood, 24-inch span Flintlastic SA NailBase OMG #14 HD with OMG 3 in. Round Metal Plate or Trufast #12 DP or #14 HD with Trufast 3” Metal Insulation Plate 6-inch o.c. at min. 2-inch lap and 6-inch o.c. in four (4), equally spaced, staggered center rows FlintPrime QD at stress plates (Optional) SBS-SA SBS-SA -127.5* HYBRID SYSTEMS: W-89 Min. 15/32-inch plywood, 24-inch span Glasbase Base Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet OMG #14 HD with OMG 3 in. Round Metal Plate or Trufast #12 DP or #14 HD with Trufast 3” Metal Insulation Plate 6-inch o.c. at 4-inch lap and 6- inch o.c. in three (3), equally spaced, staggered center rows FlintPrime QD at stress plates SBS-SA-H SBS-AA or APP-TA -97.5 W-90 Min. 19/32-inch plywood, 24-inch span Glasbase Base Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet Note 2 7-inch o.c. at 3-inch lap and 7- inch o.c. in three (3), equally spaced, staggered center rows None SBS-SA-H SBS-AA or APP-TA -105.0 W-91 Min. 15/32-inch plywood, 24-inch span Glasbase Base Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet OMG #14 HD with OMG 3 in. Round Metal Plate or Trufast #12 DP or #14 HD with Trufast 3” Metal Insulation Plate 6-inch o.c. at 4-inch lap and 6- inch o.c. in four (4), equally spaced, staggered center rows FlintPrime QD at stress plates SBS-SA-H SBS-AA or APP-TA -127.5 CONVENTIONAL SYSTEMS: W-92 Min. 23/32-inch plywood, 24-inch span Glasbase Base Sheet, All Weather/Empire Base Sheet, Flintlastic Base 20 or Flintglas MS Cap (inverted) Note 2 12-inch o.c. at 4-inch lap and 36- inch o.c. in two (2), equally spaced, staggered center rows None BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP-TA -30.0* W-93 Min. 23/32-inch plywood, 24-inch span Glasbase Base Sheet, All Weather/Empire Base Sheet, Flintlastic Base 20 or Flintglas MS Cap (inverted) Note 2 12-inch o.c. at 4-inch lap and 24- inch o.c. in two (2), equally spaced, staggered center rows None BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP-TA -45.0* W-94 Min. 23/32-inch plywood, 24-inch span Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet Note 2 12-inch o.c. at 4-inch lap and 36- inch o.c. in two (2), equally spaced, staggered center rows None BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP-TA -45.0* W-95 Min. 15/32-inch plywood, 24-inch span Glasbase Base Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet or Flintglas MS Cap (inverted) OMG #14 HD with OMG 3 in. Round Metal Plate or Trufast #12 DP or #14 HD with Trufast 3” Metal Insulation Plate 6-inch o.c. at 4-inch lap and 6- inch o.c. in three (3), equally spaced, staggered center rows None (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP-TA -97.5 W-96 Min. 15/32-inch plywood, 24-inch span Flintlastic APP Base T OMG #14 HD with OMG 3 in. Round Metal Plates 6-inch o.c. at 4-inch lap and 6- inch o.c. in three (3), equally spaced, staggered center rows. None APP-TA APP-TA -97.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R29 for FL2533-R28 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 29: 04/14/2022 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 18 of 70 TABLE 1G: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE E-2: NON-INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Base Sheet Primer Roof Cover (Note 15) MDP (psf) Base Fasteners Attach Base Ply Cap Ply W-97 Min. 15/32-inch plywood, 24-inch span Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet or Flintglas MS Cap (inverted) Trufast #14 HD with Trufast 3” Metal Insulation Plate 8-inch o.c. at 4-inch lap and 8- inch o.c. at three (3) equally spaced, staggered center rows None (Optional) BP-AA, SBS- AA or SBS-TA SBS-AA -97.5 W-98 Min. 19/32-inch plywood, 24-inch span Glasbase Base Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet or Flintglas MS Cap (inverted) Note 2 7-inch o.c. at 3-inch lap and 7- inch o.c. in three (3), equally spaced, staggered center rows None BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP-TA -105.0 W-99 Min. 19/32-inch plywood, 24-inch span Flintlastic APP Base T Dekfast DF-#14-PH3 with PLT-H-2-7/8 or OMG #14 HD with OMG 3 in. Round Metal Plate 7-inch o.c. at 3-inch lap and 7- inch o.c. in three (3), equally spaced, staggered center rows None APP-TA APP-TA -105.0 W-100 Min. 15/32-inch plywood, 24-inch span Glasbase Base Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet or Flintglas MS Cap (inverted) OMG #14 HD with OMG 3 in. Round Metal Plate or Trufast #12 DP or #14 HD with Trufast 3” Metal Insulation Plate 6-inch o.c. at 4-inch lap and 6- inch o.c. in four (4), equally spaced, staggered center rows None (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP-TA -127.5 W-101 Min. 15/32-inch plywood, 24-inch span Flintlastic APP Base T OMG #14 HD with OMG 3 in. Round Metal Plates 6-inch o.c. at 4-inch lap and 6- inch o.c. in four (4), equally spaced, staggered center rows. None APP-TA APP-TA -127.5 COLD-APPLIED SYSTEMS: W-102 Min. 15/32-inch plywood, 24-inch span Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet or Flintglas MS Cap (inverted) Trufast #12 DP or #14 HD with Trufast 3” Metal Insulation Plate 8-inch o.c. at 4-inch lap and 8- inch o.c. in three (3), equally spaced, staggered center rows None (Optional) SBS-CA1 SBS-CA1 -52.5 TABLE 1H: WOOD DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE F: NON-INSULATED, BONDED ROOF COVER System No. Deck (Note 1) Primer Roof Cover (Note 15) MDP (psf) Base Ply Ply Cap Ply W-103 APA rated, min. 7/16 CAT, 0.418 in., Exposure 1, OSB sheathing, 24-inch span FlintPrime QD Flintlastic SA Mid Ply, self-adhering (Optional) SBS-SA SBS-SA -90.0 W-104 Min. 15/32-inch plywood, 24-inch span FlintPrime QD SBS-SA-H (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -112.5 W-105 Min. 15/32-inch plywood, 24-inch span FlintPrime QD SBS-SA (Optional) SBS-SA SBS-SA -127.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R29 for FL2533-R28 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 29: 04/14/2022 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 19 of 70 TABLE 2A: STEEL OR STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE B-1: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Fasteners Attach Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply SELF-ADHERING SYSTEMS: S-1 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 2-inch ACFoam II, ENRGY 3 or H- Shield Note 2 1 per 4.0 ft2 Optional min. 1.5-inch additional layer(s) base insulation, followed by min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board hot asphalt, M- OSFA, Insta Stik, OB500, Polyset BM, Polyset CRA SBS-SA (Optional) SBS-SA SBS-SA -37.5* S-2 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 1.5-inch ACFoam II, ENRGY 3 or H- Shield Note 2 1 per 2.0 ft2 Optional min. 1.5-inch additional layer(s) base insulation, followed by min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board hot asphalt, M- OSFA, Insta Stik, OB500, Polyset BM, Polyset CRA SBS-SA (Optional) SBS-SA SBS-SA -45.0* HYBRID SYSTEMS: S-3 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 1.5-inch ACFoam II, ENRGY 3 or H- Shield Note 2 1 per 1.45 ft2 Additional layer(s) base insulation hot asphalt, M- OSFA, Insta Stik, OB500, Polyset BM, Polyset CRA Flintlastic Ultra Glass SA (Optional) SBS- AA, SBS-TA, APP- TA SBS-AA, APP-TA -37.5 S-4 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 1.5-inch ACFoam II, ENRGY 3 or H- Shield Note 2 1 per 1.45 ft2 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board hot asphalt, M- OSFA, Insta Stik, OB500, Polyset BM, Polyset CRA Flintlastic Ultra Glass SA (Optional) SBS- AA, SBS-TA, APP- TA SBS-AA, APP-TA -52.5 S-5 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 1.5-inch ACFoam II or H- Shield Trufast #12 DP or #14 HD with Trufast 3”Metal Insulation Plates 1 per 1.45 ft2 Min. 1.5-inch ACFoam II or H- Shield hot asphalt, M- OSFA, M-PG1, Insta Stik, OB500 SBS-SA-H (Optional) APP- TA APP-TA -67.5 S-6 Min. 22 ga., type B, Grade 40 steel or min. 2,500 psi structrual concrete Min. 1.5-inch ACFoam II or H- Shield Trufast #12 DP (steel only) or #14 HD with Trufast 3” Metal Insulation Plate 1 per 1.6 ft2 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board M-OSFA, M-PG1, Insta Stik, OB500 SBS-SA-H (Optional) SBS-TA or APP-TA APP-TA -75.0 S-7 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 1.5-inch ENRGY 3 Trufast #12 DP (steel only) or #14 HD with Trufast 3” Metal Insulation Plate 1 per 1.0 ft2 Min. 0.5-inch SECUROCK Gypsum-Fiber Roof Board OB500, 4-inch o.c. SBS-SA-H (Optional) SBS-TA or APP-TA APP-TA -90.0* CONVENTIONAL SYSTEMS: S-8 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 2-inch ACFoam II, ENRGY 3 or H- Shield Note 2 1 per 4.0 ft2 Optional min. 1.5-inch additional layer(s) base insulation, followed by min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board hot asphalt, M- OSFA, Insta Stik, OB500, Polyset BM, Polyset CRA BP-AA, SBS- AA, SBS-TA or APP-TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA or APP-TA -37.5* NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R29 for FL2533-R28 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 29: 04/14/2022 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 20 of 70 TABLE 2A: STEEL OR STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE B-1: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Fasteners Attach Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply S-9 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 1.5-inch ACFoam II, ENRGY 3 or H- Shield Note 2 1 per 2.0 ft2 Optional min. 1.5-inch additional layer(s) base insulation, followed by min. 0.5-inch Structodek High Density Fiberboard Roof Insulation, min. 0.75-inch FescoBoard (homogeneous). hot asphalt BP-AA or SBS-AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA or APP-TA -45.0* S-10 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 1.5-inch ACFoam II, ENRGY 3 or H- Shield Note 2 1 per 2.0 ft2 Optional min. 1.5-inch additional layer(s) base insulation, followed by min. 0.25-inch DensDeck or DensDeck Prime hot asphalt BP-AA, SBS- AA, SBS-TA or APP-TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA or APP-TA -45.0* S-11 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 1.5-inch ACFoam II, ENRGY 3 or H- Shield Note 2 1 per 2.0 ft2 Optional min. 1.5-inch additional layer(s) base insulation, followed by min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board hot asphalt, M- OSFA, Insta Stik, OB500, Polyset BM, Polyset CRA BP-AA, SBS- AA, SBS-TA or APP-TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA or APP-TA -45.0* S-12 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 2-inch ACFoam II, ENRGY 3 or H- Shield Note 2 1 per 3.2 ft2 Optional min. 1.5-inch additional layer(s) base insulation, followed by min. 0.5-inch Structodek High Density Fiberboard Roof Insulation, min. 0.75-inch FescoBoard (homogeneous). hot asphalt BP-AA or SBS-AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA or APP-TA -45.0* S-13 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 2-inch ACFoam II, ENRGY 3 or H- Shield Note 2 1 per 3.2 ft2 Optional min. 1.5-inch additional layer(s) base insulation, followed by min. 0.25-inch DensDeck or DensDeck Prime hot asphalt BP-AA, SBS- AA, SBS-TA or APP-TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA or APP-TA -45.0* S-14 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 1.5-inch ACFoam II, ENRGY 3 or Multi-Max FA3 Note 2 1 per 1.3 ft2 Min. 0.75-inch FescoBoard (homogeneous) hot asphalt BP-AA or SBS-AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA or APP-TA -52.5 S-15 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 2-inch ACFoam II, ENRGY 3 or H- Shield Note 2 1 per 1.6 ft2 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board hot asphalt, M- OSFA, Insta Stik, OB500, Polyset BM, Polyset CRA BP-AA, SBS- AA, SBS-TA or APP-TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA or APP-TA -60.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R29 for FL2533-R28 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 29: 04/14/2022 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 21 of 70 TABLE 2A: STEEL OR STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE B-1: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Fasteners Attach Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply S-16 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 1.5-inch ACFoam II, ENRGY 3 or Multi-Max FA3 Note 2 1 per 1.3 ft2 Min. 0.5-inch Structodek High Density Fiberboard hot asphalt BP-AA or SBS-AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA or APP-TA -67.5 S-17 Min. 22 ga., type B, Grade 40 steel or min. 2,500 psi structrual concrete Min. 1.5-inch ACFoam II or H- Shield Trufast #12 DP (steel only) or #14 HD with Trufast 3” Metal Insulation Plate 1 per 1.6 ft2 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board M-OSFA, M-PG1, Insta Stik, OB500 BP-AA, SBS- AA, SBS-TA or APP-TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA or APP-TA -75.0 S-18 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 1.5-inch ENRGY 3 Trufast #12 DP (steel only) or #14 HD with Trufast 3” Metal Insulation Plate 1 per 1.0 ft2 Min. 0.5-inch SECUROCK Gypsum-Fiber Roof Board OB500, 4-inch o.c. BP-AA, SBS- AA, SBS-TA or APP-TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA or APP-TA -90.0* COLD-APPLIED SYSTEMS: S-19 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 2-inch ACFoam II or H- Shield Trufast #12 DP (steel only) or #14 HD with Trufast 3” Metal Insulation Plate 1 per 2.0 ft2 Min. 1.5-inch ACFoam III or H-Shield CG OB500 or Polyset CRA SBS-CA1 None SBS-CA1 -45.0* S-20 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 2-inch ACFoam II or H- Shield Trufast #12 DP (steel only) or #14 HD with Trufast 3” Metal Insulation Plate 1 per 2.0 ft2 Optional min. 1.5-inch additional layer(s) base insulation, followed by min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Insta Stik, M-OSFA, M-PG1, OB500, Polyset BM or Polyset CRA SBS-CA1 None SBS-CA1 -45.0* S-21 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 2-inch ACFoam II or H- Shield Trufast #12 DP (steel only) or #14 HD with Trufast 3” Metal Insulation Plate 1 per 2.0 ft2 Optional min. 1.5-inch additional layer(s) base insulation, followed by min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Insta Stik, M-OSFA, M-PG1, OB500, Polyset BM or Polyset CRA SBS-CA4 None SBS-CA4 -45.0* S-22 Min. 22 ga., type B, Grade 40 steel or min. 2,500 psi structrual concrete Min. 1.5-inch ACFoam II or H- Shield Trufast #12 DP (steel only) or #14 HD with Trufast 3” Metal Insulation Plate 1 per 1.6 ft2 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board M-OSFA, M-PG1, Insta Stik, OB500 SBS-CA1 None SBS-CA1 -75.0 S-23 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 1.5-inch ENRGY 3 Trufast #12 DP (steel only) or #14 HD with Trufast 3” Metal Insulation Plate 1 per 1.0 ft2 Min. 0.5-inch SECUROCK Gypsum-Fiber Roof Board OB500, 4-inch o.c. SBS-CA1 None SBS-CA1 -90.0* NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R29 for FL2533-R28 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 29: 04/14/2022 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 22 of 70 TABLE 2B: STEEL OR STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer(s) (Note 13) Top Insulation Layer Primer Roof Cover (Note 15) MDP (psf) Type Fasteners Attach Base Ply Ply Cap Ply SELF-ADHERING SYSTEMS: S-24 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Note 2 1 per 3.2 ft2 None SBS-SA (Optional) SBS- SA SBS-SA -30.0* S-25 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Trufast #12 DP (steel only) or #14 HD with Trufast 3” Metal Insulation Plate 1 per 2.7 ft2 None SBS-SA (Optional) SBS- SA SBS-SA -37.5* S-26 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 3/8-inch SECUROCK Gypsum-Fiber Roof Board Note 2 1 per 2.7 ft2 None SBS-SA (Optional) SBS- SA SBS-SA -45.0* S-27 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 0.25-inch DensDeck Note 2 1 per 1.3 ft2 FlintPrime QD SBS-SA (Optional) SBS- SA SBS-SA -45.0 S-28 Min. 22 ga., type B, Grade 40 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 1.5-inch ACFoam II Trufast #14 HD with Trufast 3” Metal Insulation Plate 1 per 1.8 ft2 FlintPrime QD SBS-SA (Optional) SBS- SA SBS-SA -67.5 S-29 Min. 22 ga., type B, Grade 40 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 0.5-inch SECUROCK Gypsum-Fiber Roof Board Trufast #14 HD with Trufast 3” Metal Insulation Plate 1 per 1.6 ft2 FlintPrime QD SBS-SA (Optional) SBS- SA SBS-SA -82.5 S-30 Min. 22 ga., type B, Grade 40 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 1.5-inch ACFoam II or H-Shield Trufast #15 EHD (steel only) or Trufast #14 HD (concrete only) with Trufast 3” Metal Insulation Plate 1 per 1.0 ft2 FlintPrime QD SBS-SA (Optional) SBS- SA SBS-SA -97.5 HYBRID SYSTEMS: S-31 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 0.25-inch DensDeck, DensDeck Prime Note 2 1 per 2.0 ft2 None SBS-SA- H (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -30.0* S-32 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Trufast #12 DP (steel only) or #14 HD with Trufast 3” Metal Insulation Plate 1 per 2.7 ft2 None SBS-SA- H (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -37.5* S-33 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 3/8-inch SECUROCK Gypsum-Fiber Roof Board Trufast #12 DP (steel only) or #14 HD with Trufast 3” Metal Insulation Plate 1 per 2.7 ft2 None SBS-SA- H (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -45.0* S-34 Min. 22 ga., type B, Grade 40 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 1.5-inch ACFoam II Trufast #14 HD with Trufast 3” Metal Insulation Plate 1 per 1.8 ft2 None SBS-SA- H (Optional) SBS- TA or APP-TA APP-TA -67.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R29 for FL2533-R28 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 29: 04/14/2022 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 23 of 70 TABLE 2B: STEEL OR STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer(s) (Note 13) Top Insulation Layer Primer Roof Cover (Note 15) MDP (psf) Type Fasteners Attach Base Ply Ply Cap Ply S-35 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 1.5-inch ACFoam II or H-Shield Trufast #12 DP (steel only) or Trufast #14 HD with Trufast 3” Metal Insulation Plate 1 per 1.45 ft2 None SBS-SA- H (Optional) SBS- AA, SBS-TA or APP-TA SBS-AA or APP-TA -75.0 S-36 Min. 22 ga., type B, Grade 40 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 0.5-inch SECUROCK Gypsum-Fiber Roof Board Trufast #14 HD with Trufast 3” Metal Insulation Plate 1 per 1.6 ft2 None SBS-SA- H (Optional) SBS- TA or APP-TA APP-TA -82.5 S-37 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 0.5-inch SECUROCK Gypsum-Fiber Roof Board Trufast #12 DP (steel only) or #14 HD with Trufast 3” Metal Insulation Plate 1 per 1.45 ft2 None SBS-SA- H (Optional) SBS- TA or APP-TA APP-TA -82.5 S-38 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 1.5-inch ACFoam II, ENRGY 3 or Multi-Max FA3 Note 2 1 per 1.3 ft2 None SBS-SA- H (Optional) SBS- AA, SBS-TA or APP-TA SBS-AA or APP-TA -82.5 S-39 Min. 22 ga., type B, Grade 40 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 1.5-inch ACFoam II or H-Shield Trufast #15 EHD (steel only) or Trufast #14 HD (concrete only) with Trufast 3” Metal Insulation Plate 1 per 1.0 ft2 None SBS-SA- H (Optional) SBS- AA, SBS-TA or APP-TA SBS-AA or APP-TA -97.5 S-40 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 0.5-inch SECUROCK Gypsum-Fiber Roof Board Trufast #12 DP (steel only) or #14 HD with Trufast 3” Metal Insulation Plate 1 per 1.0 ft2 None SBS-SA- H (Optional) SBS- TA or APP-TA APP-TA -135.0 CONVENTIONAL SYSTEMS: S-41 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 0.75-inch FescoBoard (homogeneous) Note 2 1 per 2.7 ft2 None BP-AA, SBS-AA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -30.0* S-42 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation Note 2 1 per 4.0 ft2 None BP-AA, SBS-AA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -37.5* S-43 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Note 2 1 per 4.0 ft2 None BP-AA, SBS-AA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -37.5* S-44 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Note 2 1 per 4.0 ft2 None BP-AA, SBS-AA, SBS-TA or APP- TA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -45.0* NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R29 for FL2533-R28 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 29: 04/14/2022 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 24 of 70 TABLE 2B: STEEL OR STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer(s) (Note 13) Top Insulation Layer Primer Roof Cover (Note 15) MDP (psf) Type Fasteners Attach Base Ply Ply Cap Ply S-45 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation, min. 0.75- inch FescoBoard (homogeneous) Note 2 1 per 2.0 ft2 None BP-AA or SBS-AA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -45.0* S-46 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 0.25-inch DensDeck or DensDeck Prime Note 2 1 per 2.0 ft2 None BP-AA, SBS-AA, SBS-TA or APP- TA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -45.0* S-47 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 1.5-inch, One or more layers, any combination, loose laid Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Trufast #12 DP (steel only) or Trufast #14 HD with Trufast 3” Metal Insulation Plate 1 per 1.45 ft2 None APP-TA (Optional) APP- TA APP-TA -60.0 S-48 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 2-inch ACFoam II, ENRGY 3 or H-Shield, loose laid. Min. 0.5-inch SECUROCK Gypsum-Fiber Roof Board Note 2 1 per 1.8 ft2 None BP-AA, SBS-AA, SBS-TA or APP- TA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -60.0 S-49 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 0.5-inch SECUROCK Gypsum-Fiber Roof Board Trufast #12 DP (steel only) or #14 HD with Trufast 3” Metal Insulation Plate 1 per 1.45 ft2 None BP-AA, SBS-AA, SBS-TA or APP- TA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -82.5 S-50 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 1.5-inch ACFoam II or H-Shield Min. 0.5-inch DensDeck Prime Trufast #14 HD with Trufast 3” Metal Insulation Plate 1 per 1.3 ft2 None BP-AA, SBS-AA (Optional) BP- AA, SBS-AA SBS-AA -112.5 S-51 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 0.5-inch SECUROCK Gypsum-Fiber Roof Board Trufast #12 DP (steel only) or #14 HD with Trufast 3” Metal Insulation Plate 1 per 1.0 ft2 None BP-AA, SBS-AA, SBS-TA or APP- TA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -135.0 S-52 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 1.5-inch ACFoam II or H-Shield Min. 0.5-inch SECUROCK Gypsum-Fiber Roof Board Trufast #14 HD with Trufast 3” Metal Insulation Plate 1 per 1.3 ft2 None BP-AA, SBS-AA (Optional) BP- AA, SBS-AA SBS-AA -157.5 S-53 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 1.5-inch ACFoam II or H-Shield Min. 0.5-inch DensDeck Prime Trufast #14 HD with Trufast 3” Metal Insulation Plate 1 per 1.0 ft2 None BP-AA, SBS-AA (Optional) BP- AA, SBS-AA SBS-AA -157.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R29 for FL2533-R28 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 29: 04/14/2022 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 25 of 70 TABLE 2B: STEEL OR STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer(s) (Note 13) Top Insulation Layer Primer Roof Cover (Note 15) MDP (psf) Type Fasteners Attach Base Ply Ply Cap Ply S-54 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 1.5-inch ACFoam II or H-Shield Min. 0.5-inch SECUROCK Gypsum-Fiber Roof Board Trufast #14 HD with Trufast 3” Metal Insulation Plate 1 per 1.0 ft2 None BP-AA, SBS-AA (Optional) BP- AA, SBS-AA SBS-AA -172.5 SPOT- OR STRIP-MOPPED SYSTEMS: S-55 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 2-inch ACFoam II or ENRGY 3 Note 2 1 per 1.6 ft2 None BP-AA2 (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -37.5* S-56 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 1-inch FescoBoard (homogeneous) or min. 1.5- inch FescoBoard (laminated) Note 2 1 per 1.6 ft2 None BP-AA2 (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -45.0* S-57 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 0.5-inch Structodek HD with Primed Red Coating Note 2 1 per 2.0 ft2 None BP-AA2 (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -45.0* S-58 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 1.5-inch ACFoam II Note 2 1 per 1.45 ft2 None BP-AA3, 24-inch grid (Optional) BP-AA or SBS-AA SBS-AA -52.5 S-59 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 1.5-inch ACFoam II Note 2 1 per 1.45 ft2 None BP-AA3, 24-inch grid BP-AA or SBS-AA SBS-TA -52.5 COLD-APPLIED SYSTEMS: S-60 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Trufast #12 DP (steel only) or #14 HD with Trufast 3” Metal Insulation Plate 1 per 2.7 ft2 None SBS-CA1 None SBS-CA1 -37.5* S-61 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Trufast #12 DP (steel only) or #14 HD with Trufast 3” Metal Insulation Plate 1 per 2.7 ft2 None SBS-CA4 None SBS-CA4 -37.5* S-62 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 1.5-inch ACFoam III or H-Shield CG Trufast #12 DP (steel only) or #14 HD with Trufast 3” Metal Insulation Plate 1 per 2.0 ft2 None SBS-CA1 None SBS-CA1 -45.0* S-63 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 3/8-inch SECUROCK Gypsum-Fiber Roof Board Trufast #12 DP (steel only) or #14 HD with Trufast 3” Metal Insulation Plate 1 per 2.7 ft2 None SBS-CA1 None SBS-CA1 -45.0* S-64 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 3/8-inch SECUROCK Gypsum-Fiber Roof Board Trufast #12 DP (steel only) or #14 HD with Trufast 3” Metal Insulation Plate 1 per 2.7 ft2 None SBS-CA4 None SBS-CA4 -45.0* S-65 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 0.5-inch SECUROCK Gypsum-Fiber Roof Board Trufast #12 DP (steel only) or #14 HD with Trufast 3” Metal Insulation Plate 1 per 1.45 ft2 None SBS-CA1 None SBS-CA1 -82.5* NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R29 for FL2533-R28 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 29: 04/14/2022 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 26 of 70 TABLE 2C: STEEL OR STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE D-2: INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Insulation Layer(s) (Note 13) Base Sheet Roof Cover (Note 15) MDP (psf) Type Attach Type Fasteners Attach Base Ply Cap Ply SELF-ADHERING SYSTEMS: S-66 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 1.5-inch, One or more layers, any combination Prelim. Attached Flintlastic SA NailBase Note 2 9-inch o.c. at min. 2-inch lap and 18-inch o.c. in two (2), equally spaced, staggered center rows (Optional) SBS- SA SBS-SA -45.0* S-67 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 1.5-inch, One or more layers, any combination Prelim. Attached Flintlastic SA NailBase Note 2 12-inch o.c. at min. 2-inch lap and 12-inch o.c. in two (2), equally spaced, staggered center rows (Optional) SBS- SA SBS-SA -52.5* S-68 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 1.5-inch, One or more layers, any combination Prelim. Attached Flintlastic SA NailBase Note 2 12-inch o.c. at min. 4-inch lap and 12-inch o.c. in two (2), equally spaced, staggered center rows (Optional) SBS- SA SBS-SA -60.0* S-69 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 1.5-inch, One or more layers, any combination Prelim. Attached Flintlastic SA NailBase (laid parallel to deck flutes) Note 2 8-inch o.c. at min. 4-inch lap and 8- inch o.c. in two (2), equally spaced, staggered center rows, FlintPrime QD at stress plates (Optional) SBS- SA SBS-SA -82.5* CONVENTIONAL SYSTEMS: S-70 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 1.5-inch, One or more layers, any combination Prelim. Attached Glasbase Base Sheet, All Weather/Empire Base Sheet, Flintlastic Base 20 or Flintglas MS Cap (inverted) Note 2 12-inch o.c. at 4-inch lap and 36- inch o.c. in two (2), equally spaced, staggered center rows BP-AA, SBS-AA, SBS-TA or APP- TA SBS-AA or APP-TA -30.0* S-71 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 1.5-inch, One or more layers, any combination Prelim. Attached Glasbase Base Sheet, All Weather/Empire Base Sheet, Flintlastic Base 20 or Flintglas MS Cap (inverted) Note 2 12-inch o.c. at 4-inch lap and 24- inch o.c. in two (2), equally spaced, staggered center rows BP-AA, SBS-AA, SBS-TA or APP- TA SBS-AA or APP-TA -45.0* S-72 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 1.5-inch, One or more layers, any combination Prelim. Attached Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet Note 2 12-inch o.c. at 4-inch lap and 36- inch o.c. in two (2), equally spaced, staggered center rows BP-AA, SBS-AA, SBS-TA or APP- TA SBS-AA or APP-TA -45.0* S-73 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 1.5-inch, One or more layers, any combination Prelim. Attached Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet Note 2 18-inch o.c. at 4-inch lap and 18- inch o.c. in one (1) staggered center row BP-AA, SBS-AA, SBS-TA or APP- TA SBS-AA or APP-TA -45.0* S-74 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 1.5-inch, One or more layers, any combination Prelim. Attached Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet Dekfast DF-#14-PH3 with PLT-R-2-4B 12-inch o.c. within the min. 4-inch wide, heat-welded side lap SBS-AA, SBS-TA or APP-TA SBS-AA or APP-TA -45.0* S-75 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 1.5-inch, One or more layers, any combination Prelim. Attached Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet, Flintlastic Poly SMS Base Sheet or Flintglas MS Cap (inverted) Note 2 12-inch o.c. at 3-inch lap and 12- inch o.c. in two (2), equally spaced, staggered center rows BP-AA, SBS-AA, SBS-TA or APP- TA SBS-AA or APP-TA -52.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R29 for FL2533-R28 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 29: 04/14/2022 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 27 of 70 TABLE 2C: STEEL OR STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE D-2: INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Insulation Layer(s) (Note 13) Base Sheet Roof Cover (Note 15) MDP (psf) Type Attach Type Fasteners Attach Base Ply Cap Ply S-76 Min. 22 ga., type B, 40 ksi steel or min. 2,500 psi structrual concrete Min. 2-inch, One or more layers, any combination Prelim. Attached Flintlastic Ultra Poly SMS Base Sheet Trufast #15 EHD (steel only) or Trufast #14 HD (concrete only) with Trufast 2” Barbed Metal Seam Plate 12-inch o.c. within the min. 4-inch wide, heat-welded side lap (Optional) SBS- TA or APP-TA APP-TA -52.5 S-77 Min. 22 ga., type B, Grade 80 steel or min. 2,500 psi structrual concrete Min. 1.5-inch, One or more layers, any combination Prelim. Attached Flintlastic Ultra Poly SMS Base Sheet Trufast #15 EHD (steel only) or Trufast #14 HD (concrete only) with Trufast 2.4” Barbed Metal Seam Plate 12-inch o.c. within the min. 4-inch wide, heat-welded side lap (Optional) SBS- TA or APP-TA APP-TA -60.0 S-78 Min. 22 ga., type B, 40 ksi steel or min. 2,500 psi structrual concrete Min. 2-inch, One or more layers, any combination Prelim. Attached Flintlastic Ultra Poly SMS Base Sheet Trufast #15 EHD (steel only) or Trufast #14 HD (concrete only) with Trufast 2.4” Scoop Seam Plate 12-inch o.c. within the min. 4-inch wide, heat-welded side lap (Optional) SBS- TA or APP-TA APP-TA -67.5 S-79 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 1.5-inch, One or more layers, any combination Prelim. Attached Glasbase Base Sheet or Flintglas MS Cap (inverted) OMG #14 HD with OMG Flat Bottom Plates (AccuTrac) 6-inch o.c. at 4-inch lap and 6-inch o.c. in two (2), equally spaced, staggered center rows BP-AA, SBS-AA, SBS-TA or APP- TA SBS-AA or APP-TA -67.5 S-80 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 1.5-inch, One or more layers, any combination Prelim. Attached Flintlastic Base 20 or Flintglas MS Cap (inverted) Note 2 6-inch o.c. at 4-inch lap and 6-inch o.c. in two (2), equally spaced, staggered center rows BP-AA, SBS-AA, SBS-TA or APP- TA SBS-AA or APP-TA -67.5 S-81 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 1.5-inch, One or more layers, any combination Prelim. Attach Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet or Flintglas MS Cap (inverted) Trufast #14 HD with Trufast 3” Metal Insulation Plate 6-inch o.c. at 4-inch lap and 6-inch o.c. at three (3) equally spaced, staggered center rows (Optional) BP- AA, SBS-AA or SBS-TA SBS-AA -97.5 S-82 Min. 22 ga., type B, 40 ksi steel or min. 2,500 psi structrual concrete Min. 2-inch, One or more layers, any combination Prelim. Attached Flintlastic Ultra Poly SMS Base Sheet Trufast #15 EHD (steel only) or Trufast #14 HD (concrete only) with Trufast 2.4” Scoop Seam Plate 6-inch o.c. within the min. 4-inch wide, heat-welded side lap (Optional) SBS- TA or APP-TA APP-TA -112.5 S-83 Min. 22 ga., type B, Grade 80 steel or min. 2,500 psi structrual concrete Min. 1.5-inch, One or more layers, any combination Prelim. Attached Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet Note 2 12-inch o.c. at 4-inch lap and 12- inch o.c. in two (2), equally spaced, staggered center rows SBS-TA or APP- TA APP-TA -112.5 S-84 Min. 22 ga., type B, Grade 80 steel or min. 2,500 psi structrual concrete Min. 1.5-inch, One or more layers, any combination Prelim. Attached Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet Note 2 12-inch o.c. at 4-inch lap and 12- inch o.c. in two (2), equally spaced, staggered center rows SBS-AA SBS-AA -120.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R29 for FL2533-R28 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 29: 04/14/2022 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 28 of 70 TABLE 2C: STEEL OR STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE D-2: INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Insulation Layer(s) (Note 13) Base Sheet Roof Cover (Note 15) MDP (psf) Type Attach Type Fasteners Attach Base Ply Cap Ply S-85 Min. 22 ga., type B, 40 ksi steel or min. 2,500 psi structrual concrete Min. 2-inch, One or more layers, any combination Prelim. Attached Flintlastic Ultra Poly SMS Base Sheet Trufast #15 EHD (steel only) or Trufast #14 HD (concrete only) with Trufast 2.4” Scoop Seam Plate 6-inch o.c. within the min. 4-inch wide, heat-welded side laps and 6- inch o.c. in one (1) center row, stripped-in with 6-inch side strips of torch-applied Flintlastic Poly SMS Base Sheet or Flintlastic Ultra Poly SMS Base Sheet. (Optional) SBS- TA or APP-TA APP-TA -165.0 COLD-APPLIED SYSTEMS: S-86 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 1.5-inch, One or more layers, any combination Prelim. Attached Glasbase Base Sheet, All Weather/Empire Base Sheet, Flintlastic Base 20 Note 2 6-inch o.c. at 4-inch lap and 12- inch o.c. in two (2), equally spaced, staggered center rows SBS-CA1 SBS-CA1 -45.0* S-87 Min. 22 ga., type B, Grade 40 steel or min. 2,500 psi structrual concrete Min. 1-inch, One or more layers, any combination Loose-laid Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet Trufast #14 HD with Trufast 3” Metal Insulation Plate 6-inch o.c. at 4-inch lap and 12- inch o.c. in three (3), equally spaced, staggered center rows (Optional) SBS- CA1 SBS-CA1 -75.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R29 for FL2533-R28 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 29: 04/14/2022 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 29 of 70 TABLE 3A: STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER SEE NOTE 16 FOR VAPOR BARRIER OPTIONS Sys. No. Deck (Note 1) Primer Base Insulation Layer Top Insulation Layer Primer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply SELF-ADHERING SYSTEMS: C-1. Structural concrete FlintPrime QD Min. 1.5-inch ACFoam II, ENRGY 3 or H-Shield hot asphalt Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board hot asphalt None SBS-SA (Optional) SBS- SA SBS-SA -172.5 C-2. Structural concrete FlintPrime QD Min. 1.5-inch ACFoam II, ENRGY 3 or Multi-Max FA3 hot asphalt Min. 0.25-inch DensDeck hot asphalt FlintPrime QD SBS-SA (Optional) SBS- SA SBS-SA -192.5 C-3. Structural concrete None (Optional) Min. 1.5-inch ACFoam II or H-Shield M-OSFA or M- PG1 Min. 0.5-inch ACFoam-HD CoverBoard or H-Shield HD M-OSFA or M- PG1 FlintPrime QD SBS-SA (Optional) SBS- SA SBS-SA -97.5 C-4. Structural concrete None (Optional) Min. 1.5-inch ACFoam II or H-Shield M-OSFA or M- PG1 Min. 2-inch H-Shield HD Composite CG M-OSFA or M- PG1 None SBS-SA (Optional) SBS- SA SBS-SA -142.5 C-5. Structural concrete None Min. 1.5-inch ACFoam II, ENRGY 3 or H-Shield M-OSFA or M- PG1 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board M-OSFA or M- PG1 None SBS-SA (Optional) SBS- SA SBS-SA -172.5 C-6. Structural concrete None Min. 1.5-inch ACFoam II, ENRGY 3 or Multi-Max FA3 M-OSFA or M- PG1 Min. 0.25-inch DensDeck M-OSFA or M- PG1 FlintPrime QD SBS-SA (Optional) SBS- SA SBS-SA -192.5 C-7. Structural concrete None (Optional) Min. 1.5-inch ACFoam II or H-Shield M-OSFA or M- PG1, 6-inch o.c. Min. 2-inch H-Shield HD Composite CG M-OSFA or M- PG1, 6-inch o.c. None SBS-SA (Optional) SBS- SA SBS-SA -305.0 C-8. Structural concrete None (Optional) Min. 1.5-inch ACFoam II or H-Shield M-OSFA or M- PG1, 6-inch o.c. Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board M-OSFA or M- PG1, 6-inch o.c. FlintPrime QD SBS-SA (Optional) SBS- SA SBS-SA -315.0 C-9. Structural concrete None (Optional) Min. 1.5-inch ACFoam II or H-Shield M-OSFA or M- PG1, 6-inch o.c. Min. 0.5-inch ACFoam-HD CoverBoard or H-Shield HD M-OSFA or M- PG1, 6-inch o.c. FlintPrime QD SBS-SA (Optional) SBS- SA SBS-SA -315.0 C-10. Structural concrete (Optional) FlintPrime QD Min. 1.5-inch Multi-Max FA Insta Stik Min. 0.25-inch DensDeck Insta Stik FlintPrime QD SBS-SA (Optional) SBS- SA SBS-SA -67.5 C-11. Structural concrete (Optional) FlintPrime QD Min. 1.5-inch ENRGY 3 Insta Stik Min. 0.25-inch DensDeck Insta Stik FlintPrime QD SBS-SA (Optional) SBS- SA SBS-SA -112.5 C-12. Structural concrete (Optional) FlintPrime QD Min. 1.5-inch ACFoam II Insta Stik Min. 0.25-inch DensDeck Insta Stik FlintPrime QD SBS-SA (Optional) SBS- SA SBS-SA -120.0 C-13. Structural concrete None Min. 1.5-inch ACFoam II, ENRGY 3 or H-Shield Insta Stik Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Insta Stik None SBS-SA (Optional) SBS- SA SBS-SA -172.5 C-14. Structural concrete FlintPrime QD Min. 1.5-inch ACFoam II or ENRGY 3 OB500 Min. 0.25-inch DensDeck OB500 FlintPrime QD SBS-SA (Optional) SBS- SA SBS-SA -120.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R29 for FL2533-R28 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 29: 04/14/2022 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 30 of 70 TABLE 3A: STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER SEE NOTE 16 FOR VAPOR BARRIER OPTIONS Sys. No. Deck (Note 1) Primer Base Insulation Layer Top Insulation Layer Primer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply C-15. Structural concrete None Min. 1.5-inch ACFoam II or ENRGY 3 OB500 Min. 0.25-inch DensDeck OB500 FlintPrime QD SBS-SA (Optional) SBS- SA SBS-SA -150.0 C-16. Structural concrete None Min. 1.5-inch ACFoam II, ENRGY 3 or H-Shield OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 None SBS-SA (Optional) SBS- SA SBS-SA -172.5 C-17. Structural concrete None Min. 1-inch ENRGY 3, H-Shield or H-Shield CG or min. 1.5-inch Multi- Max FA3 or Ultra-Max Polyset BM or Polyset CRA Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Polyset BM or Polyset CRA None SBS-SA (Optional) SBS- SA SBS-SA -172.5 C-18. Structural concrete None Min. 1-inch ENRGY 3, H-Shield or H-Shield CG or min. 1.5-inch Multi- Max FA3 or Ultra-Max Polyset BM or Polyset CRA Min. 0.25-inch DensDeck Polyset BM or Polyset CRA FlintPrime QD SBS-SA (Optional) SBS- SA SBS-SA -192.5 HYBRID SYSTEMS: C-19. Structural concrete FlintPrime QD Min. 1.5-inch ACFoam II or H- Shield hot asphalt (Optional) Additional layer(s) base insulation hot asphalt None Flintlastic Ultra Glass SA (Optional) SBS- AA, SBS-TA, APP- TA SBS-AA, APP-TA -322.5 C-20. Structural concrete FlintPrime QD Min. 1.5-inch ACFoam II or H- Shield hot asphalt (Optional) Additional layer(s) base insulation hot asphalt None Black Diamond Base Sheet (Optional) SBS- AA, SBS-TA, APP- TA SBS-AA, APP-TA -375.0 C-21. Structural concrete None (Optional) Min. 1.5-inch ACFoam II or H-Shield M-OSFA or M- PG1 Min. 0.5-inch ACFoam-HD CoverBoard or H-Shield HD M-OSFA or M- PG1 None SBS-SA-H (Optional) SBS- AA, SBS-TA, APP- TA SBS-AA, APP-TA -97.5 C-22. Structural concrete None Min. 1.5-inch ACFoam II or H- Shield M-OSFA (Optional) Additional layer(s) base insulation M-OSFA None SBS-SA-H (Optional) SBS- AA, SBS-TA, APP- TA SBS-AA, APP-TA -232.5 C-23. Structural concrete None Min. 1.5-inch ACFoam II or H- Shield M-OSFA Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board M-OSFA None SBS-SA-H (Optional) SBS- AA, SBS-TA, APP- TA SBS-AA, APP-TA -217.5 C-24. Structural concrete None Min. 1-inch Styrofoam Brand Roofmate M-OSFA or M- PG1 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board M-OSFA or M- PG1 None SBS-SA-H (Optional) SBS- AA, SBS-TA, APP- TA SBS-AA, APP-TA -210.0 C-25. Structural concrete None Min. 0.25-inch SECUROCK Gypsum- Fiber Roof Board M-OSFA None N/A None SBS-SA-H (Optional) SBS- AA, SBS-TA, APP- TA SBS-AA, APP-TA -195.0 C-26. Structural concrete None Min. 1.5-inch ACFoam II or H- Shield M-PG1 (Optional) Additional layer(s) base insulation M-PG1 None SBS-SA-H (Optional) SBS- AA, SBS-TA, APP- TA SBS-AA, APP-TA -270.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R29 for FL2533-R28 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 29: 04/14/2022 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 31 of 70 TABLE 3A: STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER SEE NOTE 16 FOR VAPOR BARRIER OPTIONS Sys. No. Deck (Note 1) Primer Base Insulation Layer Top Insulation Layer Primer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply C-27. Structural concrete None Min. 1.5-inch ACFoam II or H- Shield M-PG1 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board M-PG1 None SBS-SA-H (Optional) SBS- AA, SBS-TA, APP- TA SBS-AA, APP-TA -217.5 C-28. Structural concrete None Min. 0.25-inch SECUROCK Gypsum- Fiber Roof Board M-PG1 None N/A None SBS-SA-H (Optional) SBS- AA, SBS-TA, APP- TA SBS-AA, APP-TA -195.0 C-29. Structural concrete None (Optional) Min. 1.5-inch ACFoam II or H-Shield M-OSFA or M- PG1, 6-inch o.c. Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board or min. 0.5-inch ACFoam- HD CoverBoard or H-Shield HD M-OSFA or M- PG1, 6-inch o.c. None SBS-SA-H (Optional) SBS- AA, SBS-TA, APP- TA SBS-AA, APP-TA -315.0 C-30. Structural concrete None Min. 1.5-inch ACFoam II or H- Shield Insta Stik (Optional) Additional layer(s) base insulation Insta Stik None SBS-SA-H (Optional) SBS- AA, SBS-TA, APP- TA SBS-AA, APP-TA -135.0 C-31. Structural concrete None Min. 1.5-inch ACFoam II or H- Shield Insta Stik Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Insta Stik None SBS-SA-H (Optional) SBS- AA, SBS-TA, APP- TA SBS-AA, APP-TA -217.5 C-32. Structural concrete None Min. 0.25-inch SECUROCK Gypsum- Fiber Roof Board Insta Stik None N/A None SBS-SA-H (Optional) SBS- AA, SBS-TA, APP- TA SBS-AA, APP-TA -195.0 C-33. Structural concrete None Min. 1.5-inch ACFoam II or H- Shield OB500 (Optional) Additional layer(s) base insulation OB500 None SBS-SA-H (Optional) SBS- AA, SBS-TA, APP- TA SBS-AA, APP-TA -135.0 C-34. Structural concrete None Min. 1.5-inch ACFoam II or H- Shield OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 None SBS-SA-H (Optional) SBS- AA, SBS-TA, APP- TA SBS-AA, APP-TA -217.5 C-35. Structural concrete None Min. 0.25-inch SECUROCK Gypsum- Fiber Roof Board OB500 None N/A None SBS-SA-H (Optional) SBS- AA, SBS-TA, APP- TA SBS-AA, APP-TA -195.0 C-36. Structural concrete None Min. 1.5-inch ACFoam II or H- Shield Polyset BM or Polyset CRA (Optional) Additional layer(s) base insulation Polyset BM or Polyset CRA None SBS-SA-H (Optional) SBS- AA, SBS-TA, APP- TA SBS-AA, APP-TA -270.0 C-37. Structural concrete None Min. 1.5-inch ACFoam II or H- Shield Polyset BM or Polyset CRA Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Polyset BM or Polyset CRA None SBS-SA-H (Optional) SBS- AA, SBS-TA, APP- TA SBS-AA, APP-TA -217.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R29 for FL2533-R28 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 29: 04/14/2022 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 32 of 70 TABLE 3A: STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER SEE NOTE 16 FOR VAPOR BARRIER OPTIONS Sys. No. Deck (Note 1) Primer Base Insulation Layer Top Insulation Layer Primer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply C-38. Structural concrete None Min. 1.5-inch, min. 1.5 pcf Insulfoam II Roofing EPS Polyset CRA Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Polyset CRA None SBS-SA-H (Optional) SBS- AA, SBS-TA, APP- TA SBS-AA, APP-TA -180.0 C-39. Structural concrete None Min. 1.5-inch, min. 2.0 pcf Insulfoam IX Roofing EPS Polyset CRA Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Polyset CRA None SBS-SA-H (Optional) SBS- AA, SBS-TA, APP- TA SBS-AA, APP-TA -217.5 C-40. Structural concrete None Min. 1.5-inch Styrofoam Brand Roofmate Polyset CRA Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Polyset CRA None SBS-SA-H (Optional) SBS- AA, SBS-TA, APP- TA SBS-AA, APP-TA -217.5 C-41. Structural concrete None Min. 0.25-inch SECUROCK Gypsum- Fiber Roof Board Polyset BM or Polyset CRA None N/A None SBS-SA-H (Optional) SBS- AA, SBS-TA, APP- TA SBS-AA, APP-TA -195.0 CONVENTIONAL SYSTEMS: C-42. Structural concrete FlintPrime QD Min. 1.5-inch ACFoam II hot asphalt Min. 0.25-inch DensDeck, DensDeck Prime hot asphalt None SBS-TA (Optional) SBS- TA SBS-TA -180.0 C-43. Structural concrete FlintPrime QD (Optional) Min. 1.5-inch ACFoam II hot asphalt Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board hot asphalt None BP-AA, SBS-AA, SBS-TA or APP- TA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -180.0 C-44. Structural concrete FlintPrime QD (Optional) Min. 2-inch ACFoam II, ENRGY 3 or H-Shield hot asphalt Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board hot asphalt None BP-AA or SBS- AA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -225.0 C-45. Structural concrete FlintPrime QD (Optional) Min. 1.5-inch ACFoam II or H-Shield hot asphalt Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board hot asphalt None APP-TA (Optional) APP- TA APP-TA -252.5 C-46. Structural concrete FlintPrime QD Min. 1.5-inch ACFoam II, ENRGY 3 or H-Shield hot asphalt Min. 0.5-inch Structodek High Density Fiberboard hot asphalt None BP-AA or SBS- AA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -227.0 C-47. Structural concrete FlintPrime QD (Optional) Min. 2-inch ACFoam II, ENRGY 3 or H-Shield hot asphalt Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board hot asphalt None SBS-TA or APP- TA (Optional) SBS- TA or APP-TA APP-TA -232.5 C-48. Structural concrete FlintPrime QD Min. 1.5-inch ACFoam II, ENRGY 3 or H-Shield hot asphalt Min. 0.25-inch DensDeck hot asphalt None BP-AA or SBS- AA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -240.0 C-49. Structural concrete FlintPrime QD Min. 1.5-inch ACFoam II hot asphalt Min. 0.75-inch FescoBoard (homogeneous) hot asphalt None BP-AA or SBS- AA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -412.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R29 for FL2533-R28 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 29: 04/14/2022 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 33 of 70 TABLE 3A: STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER SEE NOTE 16 FOR VAPOR BARRIER OPTIONS Sys. No. Deck (Note 1) Primer Base Insulation Layer Top Insulation Layer Primer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply C-50. Structural concrete FlintPrime QD Min. 1.5-inch ACFoam II hot asphalt Min. 0.5-inch DuraBoard (homogeneous) hot asphalt None BP-AA or SBS- AA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -430.0 C-51. Structural concrete FlintPrime QD 0.5-inch Structodek High Density Fiberboard or min. 0.75-inch Fesco Board (homogeneous) hot asphalt None N/A None BP-AA (Optional) BP-AA or SBS-AA SBS-AA -437.5 C-52. Structural concrete FlintPrime QD 0.25-inch DensDeck, DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board hot asphalt None N/A None SBS-TA (Optional) SBS- AA or SBS-TA SBS-AA -302.5 C-53. Structural concrete FlintPrime QD 0.25-inch DensDeck, DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board hot asphalt None N/A None BP-AA (Optional) BP-AA or SBS-AA SBS-AA -537.5 C-54. Structural concrete None Min. 1.5-inch ACFoam II, ENRGY 3 or H-Shield M-OSFA Min. 0.5-inch Structodek High Density Fiberboard M-OSFA None BP-AA or SBS- AA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -127.5 C-55. Structural concrete None Min. 1.5-inch ACFoam II, ENRGY 3 or H-Shield M-PG1 Min. 0.5-inch Structodek High Density Fiberboard M-PG1 None BP-AA or SBS- AA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -180.0 C-56. Structural concrete None Min. 1.5-inch ACFoam II, ENRGY 3 or H-Shield M-OSFA Min. 0.25-inch DensDeck M-OSFA None BP-AA or SBS- AA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -232.5 C-57. Structural concrete None Min. 1.5-inch ACFoam II, ENRGY 3 or H-Shield M-PG1 Min. 0.25-inch DensDeck M-PG1 None BP-AA or SBS- AA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -240.0 C-58. Structural concrete None Min. 1.5-inch ACFoam II or H- Shield M-PG1 Min. 0.25-inch DensDeck Prime M-PG1 None BP-AA, SBS-AA (Optional) BP- AA, SBS-AA or SBS-TA SBS-AA -297.5 C-59. Structural concrete None Min. 2-inch ACFoam II, ENRGY 3 or H-Shield M-OSFA or M- PG1 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board M-OSFA or M- PG1 None BP-AA or SBS- AA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -225.0 C-60. Structural concrete None Min. 2-inch ACFoam II, ENRGY 3 or H-Shield M-OSFA or M- PG1 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board M-OSFA or M- PG1 None SBS-TA or APP- TA (Optional) SBS- TA or APP-TA APP-TA -232.5 C-61. Structural concrete None Min. 1.5-inch ACFoam II or H- Shield M-OSFA or M- PG1 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board M-OSFA or M- PG1 None APP-TA (Optional) APP- TA APP-TA -252.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R29 for FL2533-R28 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 29: 04/14/2022 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 34 of 70 TABLE 3A: STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER SEE NOTE 16 FOR VAPOR BARRIER OPTIONS Sys. No. Deck (Note 1) Primer Base Insulation Layer Top Insulation Layer Primer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply C-62. Structural concrete None Min. 1.5-inch ACFoam II or H- Shield M-OSFA or M- PG1 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board M-OSFA or M- PG1 None BP-AA, SBS-AA or SBS-TA (Optional) BP- AA, SBS-AA or SBS-TA SBS-AA -297.5 C-63. Structural concrete None 0.5-inch Structodek High Density Fiberboard M-PG1 None N/A None BP-AA, SBS-AA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -195.0 C-64. Structural concrete None Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board M-PG1 None N/A None BP-AA, SBS-AA, SBS-TA or APP- TA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -195.0 C-65. Structural concrete None (Optional) Min. 1.5-inch ACFoam II or H-Shield M-OSFA or M- PG1, 6-inch o.c. Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board M-OSFA or M- PG1, 6-inch o.c. None SBS-AA or SBS- TA (Optional) SBS- AA or SBS-TA SBS-AA -315.0 C-66. Structural concrete None (Optional) Min. 1.5-inch ACFoam II or H-Shield M-OSFA or M- PG1, 6-inch o.c. Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board M-OSFA or M- PG1, 6-inch o.c. None Flintlastic STA or Flintlastic STA Plus (Optional) APP- TA APP-TA -315.0 C-67. Structural concrete None Min. 1.5-inch ACFoam II or H- Shield Insta Stik Min. 0.25-inch DensDeck Prime Insta Stik None BP-AA, SBS-AA (Optional) BP- AA, SBS-AA or SBS-TA SBS-AA -297.5 C-68. Structural concrete None Min. 2-inch ACFoam II, ENRGY 3 or H-Shield Insta Stik Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Insta Stik None BP-AA or SBS- AA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -225.0 C-69. Structural concrete None Min. 2-inch ACFoam II, ENRGY 3 or H-Shield Insta Stik Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Insta Stik None SBS-TA or APP- TA (Optional) SBS- TA or APP-TA APP-TA -232.5 C-70. Structural concrete None Min. 1.5-inch ACFoam II or H- Shield Insta Stik Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Insta Stik None APP-TA (Optional) APP- TA APP-TA -252.5 C-71. Structural concrete None Min. 1.5-inch ACFoam II or H- Shield Insta Stik Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Insta Stik None BP-AA, SBS-AA or SBS-TA (Optional) BP- AA, SBS-AA or SBS-TA SBS-AA -297.5 C-72. Structural concrete None 0.5-inch Structodek High Density Fiberboard Insta Stik None N/A None BP-AA, SBS-AA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -195.0 C-73. Structural concrete None Min. 0.25-inch SECUROCK Gypsum- Fiber Roof Board Insta Stik None N/A None BP-AA, SBS-AA, SBS-TA or APP- TA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -195.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R29 for FL2533-R28 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 29: 04/14/2022 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 35 of 70 TABLE 3A: STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER SEE NOTE 16 FOR VAPOR BARRIER OPTIONS Sys. No. Deck (Note 1) Primer Base Insulation Layer Top Insulation Layer Primer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply C-74. Structural concrete None Min. 1.5-inch ACFoam II, ENRGY 3 or H-Shield OB500 Min. 0.5-inch Structodek High Density Fiberboard OB500 None BP-AA or SBS- AA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -120.0 C-75. Structural concrete None Min. 1.5-inch ACFoam II OB500 Min. 0.25-inch DensDeck or DensDeck Prime OB500 None BP-AA, SBS-AA, SBS-TA or APP- TA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -150.0 C-76. Structural concrete None Min. 1.5-inch ACFoam II or H- Shield OB500 Min. 0.25-inch DensDeck Prime OB500 None BP-AA, SBS-AA or SBS-TA (Optional) BP- AA, SBS-AA or SBS-TA SBS-AA -297.5 C-77. Structural concrete None Min. 2-inch ACFoam II, ENRGY 3 or H-Shield OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 None BP-AA or SBS- AA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -225.0 C-78. Structural concrete None Min. 2-inch ACFoam II, ENRGY 3 or H-Shield OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 None SBS-TA or APP- TA (Optional) SBS- TA or APP-TA APP-TA -232.5 C-79. Structural concrete None Min. 1.5-inch ACFoam II or H- Shield OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 None APP-TA (Optional) APP- TA APP-TA -252.5 C-80. Structural concrete None Min. 1.5-inch ACFoam II or H- Shield OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 None BP-AA, SBS-AA or SBS-TA (Optional) BP- AA, SBS-AA or SBS-TA SBS-AA -297.5 C-81. Structural concrete None 0.5-inch Structodek High Density Fiberboard OB500 None N/A None BP-AA, SBS-AA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -195.0 C-82. Structural concrete None Min. 0.25-inch SECUROCK Gypsum- Fiber Roof Board OB500 None N/A None BP-AA, SBS-AA, SBS-TA or APP- TA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -195.0 C-83. Structural concrete None Min. 1-inch ENRGY 3, H-Shield or H-Shield CG or min. 1.5-inch Multi- Max FA3 or Ultra-Max Polyset BM or Polyset CRA Min. 0.5-inch Structodek High Density Fiberboard Polyset CRA None BP-AA or SBS- AA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -180.0 C-84. Structural concrete None Min. 1-inch ENRGY 3, H-Shield, or H-Shield CG, min. 1.3-inch ACFoam III or min. 1.5-inch Multi-Max FA3 or Ultra-Max Polyset BM or Polyset CRA Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Polyset BM or Polyset CRA None BP-AA or SBS- AA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -225.0 C-85. Structural concrete None Min. 1-inch ENRGY 3, H-Shield or H-Shield CG or min. 1.5-inch Multi- Max FA3 or Ultra-Max Polyset BM or Polyset CRA Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Polyset BM or Polyset CRA None SBS-TA or APP- TA (Optional) SBS- TA or APP-TA APP-TA -232.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R29 for FL2533-R28 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 29: 04/14/2022 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 36 of 70 TABLE 3A: STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER SEE NOTE 16 FOR VAPOR BARRIER OPTIONS Sys. No. Deck (Note 1) Primer Base Insulation Layer Top Insulation Layer Primer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply C-86. Structural concrete None Min. 1-inch ENRGY 3, H-Shield or H-Shield CG or min. 1.5-inch Multi- Max FA3 or Ultra-Max Polyset BM or Polyset CRA Min. 0.25-inch DensDeck Polyset BM or Polyset CRA None BP-AA or SBS- AA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -240.0 C-87. Structural concrete None 0.5-inch Structodek High Density Fiberboard Polyset BM or Polyset CRA None N/A None BP-AA, SBS-AA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -195.0 C-88. Structural concrete None Min. 0.25-inch SECUROCK Gypsum- Fiber Roof Board Polyset BM or Polyset CRA None N/A None BP-AA, SBS-AA, SBS-TA or APP- TA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -195.0 SPOT- OR STRIP-MOPPED SYSTEMS: C-89. Structural concrete FlintPrime QD Min. 1.5-inch ACFoam II, ENRGY 3 or H-Shield hot asphalt (Optional) Additional layer(s) of base insulation hot asphalt None BP-AA3, 24- inch grid (Optional) BP- AA, SBS-AA SBS-AA -37.5 COLD-APPLIED SYSTEMS: C-90. Structural concrete None (Optional) Min. 1.5-inch ACFoam II or H-Shield M-OSFA or M- PG1 Min. 0.25-inch DEXcell FA Glass Mat Roof Board M-OSFA or M- PG1 None Flintlastic Poly SMS Base Sheet in Karnak #81 (Optional) Flintlastic Poly SMS Base Sheet in Karnak #81 SBS-CA1 -90.0 C-91. Structural concrete None (Optional) Min. 1.5-inch ACFoam II or H-Shield M-OSFA or M- PG1 Min. 0.5-inch ACFoam-HD CoverBoard or H-Shield HD M-OSFA or M- PG1 None SBS-CA1 None SBS-CA1 -97.5 C-92. Structural concrete None (Optional) Min. 1.5-inch ACFoam II or H-Shield M-OSFA or M- PG1 Min. 0.5-inch ACFoam-HD CoverBoard or H-Shield HD M-OSFA or M- PG1 None SBS-CA4 None SBS-CA4 -97.5 C-93. Structural concrete None Min. 0.5-inch ACFoam II or H- Shield M-OSFA or M- PG1 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board M-OSFA or M- PG1 None SBS-CA1 None SBS-CA1 -105.0 C-94. Structural concrete None Min. 0.5-inch ACFoam II or H- Shield M-OSFA or M- PG1 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board M-OSFA or M- PG1 None SBS-CA4 None SBS-CA4 -105.0 C-95. Structural concrete None (Optional) Min. 1.5-inch ACFoam II or H-Shield M-OSFA or M- PG1, 6-inch o.c. Min. 0.25-inch DEXcell FA Glass Mat Roof Board M-OSFA or M- PG1, 6-inch o.c. None Flintlastic Poly SMS Base Sheet in Karnak #81 (Optional) Flintlastic Poly SMS Base Sheet in Karnak #81 SBS-CA1 -112.5 C-96. Structural concrete None (Optional) Min. 0.5-inch ACFoam II or H-Shield OB500 Min. 1.5-inch ACFoam III or H-Shield CG OB500 None SBS-CA1 None SBS-CA1 -82.5 C-97. Structural concrete None Min. 0.5-inch ACFoam II or H- Shield OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 None SBS-CA1 None SBS-CA1 -105.0 C-98. Structural concrete None Min. 0.5-inch ACFoam II or H- Shield OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 None SBS-CA4 None SBS-CA4 -105.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R29 for FL2533-R28 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 29: 04/14/2022 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 37 of 70 TABLE 3A: STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER SEE NOTE 16 FOR VAPOR BARRIER OPTIONS Sys. No. Deck (Note 1) Primer Base Insulation Layer Top Insulation Layer Primer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply C-99. Structural concrete None (Optional) Min. 0.5-inch ACFoam II or H-Shield Polyset BM or Polyset CRA Min. 1.5-inch ACFoam III or H-Shield CG Polyset BM or Polyset CRA None SBS-CA1 None SBS-CA1 -82.5 C-100. Structural concrete None Min. 0.5-inch ACFoam II or H- Shield Polyset BM or Polyset CRA Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Polyset BM or Polyset CRA None SBS-CA1 None SBS-CA1 -105.0 C-101. Structural concrete None Min. 0.5-inch ACFoam II or H- Shield Polyset BM or Polyset CRA Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Polyset BM or Polyset CRA None SBS-CA4 None SBS-CA4 -105.0 TABLE 3B: STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-3: BONDED TEMP ROOF, BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Primer Temp Roof Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply COLD-APPLIED SYSTEMS: C-102. Structural concrete FlintPrime QD Flintlastic SA PlyBase, self-adhered (Optional) Min. 0.5-inch ACFoam II or H-Shield OB500 Min. 1.5-inch ACFoam III or H- Shield CG OB500 SBS-CA1 None SBS-CA1 -82.5 C-103. Structural concrete FlintPrime QD Flintlastic SA PlyBase, self-adhered Min. 0.5-inch ACFoam II or H- Shield OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 SBS-CA1 None SBS-CA1 -82.5 C-104. Structural concrete FlintPrime QD Flintlastic SA PlyBase, self-adhered Min. 0.5-inch ACFoam II or H- Shield OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 SBS-CA4 None SBS-CA4 -82.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R29 for FL2533-R28 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 29: 04/14/2022 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 38 of 70 TABLE 3C: STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE F: NON-INSULATED, BONDED ROOF COVER System No. Deck (Note 1) Primer Roof Cover (Note 15) MDP (psf) Base Ply Ply Cap Ply SELF-ADHERING SYSTEMS: C-105. Structural concrete FlintPrime QD SBS-SA (Optional) SBS-SA SBS-SA -630.0 HYBRID SYSTEMS: C-106. Structural concrete FlintPrime QD Flintlastic Ultra Glass SA (Optional) SBS-AA SBS-AA -135.0 C-107. Structural concrete FlintPrime QD SBS-SA-H (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -150.0 C-108. Structural concrete FlintPrime QD Flintlastic Ultra Glass SA (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -322.5 C-109. Structural concrete FlintPrime QD SBS-SA-H (Optional) BP-AA, SBS-AA SBS-AA -240.0 C-110. Structural concrete FlintPrime QD BP-AA, SBS-AA SBS-SA-H SBS-AA, SBS-TA, APP-TA -635.0 CONVENTIONAL SYSTEMS: C-111. Structural concrete FlintPrime QD APP-TA (Optional) APP-TA APP-TA -420.0 C-112. Structural concrete FlintPrime QD BP-AA, SBS-AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA or APP-TA -635.0 COLD-APPLIED SYSTEMS: C-113. Structural concrete FlintPrime QD SBS-CA1 (Optional) SBS-CA1 SBS-CA1 -262.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R29 for FL2533-R28 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 29: 04/14/2022 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 39 of 70 TABLE 4A: LIGHTWEIGHT CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Lightweight Concrete (Note 14) Base Insulation Layer Coverboard Roof Cover (Note 15) MDP (psf) Type Attach Type Attach Base Ply Ply Cap Ply CELCORE (FL2037): SELF-ADHERING SYSTEMS: LWC-1 Min. 22 ga., Type BV, Grade 33 steel, 6 ft span Min. 300 psi Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture One or more layer(s), min. 1.5-inch ACFoam II, ACFoam III, H-Shield or H-Shield CG M-OSFA Min. 0.25-inch SECUROCK Gypsum- Fiber Roof Board M-OSFA SBS-SA (Optional) SBS- SA SBS-SA -52.5 LWC-2 Min. 22 ga., Type BV, Grade 33 steel, 6 ft span Min. 300 psi Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture One or more layer(s), min. 1.5-inch ACFoam II, ACFoam III, H-Shield or H-Shield CG M-PG1 Min. 0.25-inch SECUROCK Gypsum- Fiber Roof Board M-PG1 SBS-SA (Optional) SBS- SA SBS-SA -52.5 LWC-3 Min. 22 ga., Type BV, Grade 33 steel, 6 ft span Min. 300 psi Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture One or more layer(s), min. 1.5-inch ACFoam II, ACFoam III, H-Shield or H-Shield CG OB500 Min. 0.25-inch SECUROCK Gypsum- Fiber Roof Board OB500 SBS-SA (Optional) SBS- SA SBS-SA -52.5 LWC-4 Min. 22 ga., Type BV, Grade 33 steel, 6 ft span Min. 300 psi Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture One or more layer(s), min. 1.5-inch ACFoam II, ACFoam III, H-Shield or H-Shield CG Polyset BM Min. 0.25-inch SECUROCK Gypsum- Fiber Roof Board Polyset BM SBS-SA (Optional) SBS- SA SBS-SA -52.5 LWC-5 Min. 22 ga., Type BV, Grade 33 steel, 6 ft span Min. 300 psi Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture One or more layer(s), min. 1.5-inch ACFoam II, ACFoam III, H-Shield or H-Shield CG Polyset CRA Min. 0.25-inch SECUROCK Gypsum- Fiber Roof Board Polyset CRA SBS-SA (Optional) SBS- SA SBS-SA -52.5 HYBRID SYSTEMS: LWC-6 Min. 22 ga., Type BV, Grade 33 steel, 6 ft span Min. 300 psi Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture One or more layer(s), min. 1.5-inch ACFoam II, ACFoam III, H-Shield or H-Shield CG M-OSFA, M-PG1, OB500, Polyset BM, Polyset CRA (Optional) Min. 0.25- inch SECUROCK Gypsum-Fiber Roof Board M-OSFA, M- PG1, OB500, Polyset BM, Polyset CRA SBS-SA-H (Optional) SBS- AA, SBS-TA or APP-TA SBS-AA or APP-TA -52.5 CONVENTIONAL SYSTEMS: LWC-7 Min. 22 ga., Type BV, Grade 33 steel, 6 ft span Min. 300 psi Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture One or more layer(s), min. 1.5-inch ACFoam II, ACFoam III, H-Shield or H-Shield CG M-OSFA Min. 0.25-inch SECUROCK Gypsum- Fiber Roof Board M-OSFA BP-AA or SBS-AA, SBS- TA or APP-TA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -52.5 LWC-8 Min. 22 ga., Type BV, Grade 33 steel, 6 ft span Min. 300 psi Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture One or more layer(s), min. 1.5-inch ACFoam II, ACFoam III, H-Shield or H-Shield CG M-PG1 Min. 0.25-inch SECUROCK Gypsum- Fiber Roof Board M-PG1 BP-AA or SBS-AA, SBS- TA or APP-TA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -52.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R29 for FL2533-R28 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 29: 04/14/2022 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 40 of 70 TABLE 4A: LIGHTWEIGHT CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Lightweight Concrete (Note 14) Base Insulation Layer Coverboard Roof Cover (Note 15) MDP (psf) Type Attach Type Attach Base Ply Ply Cap Ply LWC-9 Min. 22 ga., Type BV, Grade 33 steel, 6 ft span Min. 300 psi Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture One or more layer(s), min. 1.5-inch ACFoam II, ACFoam III, H-Shield or H-Shield CG OB500 Min. 0.25-inch SECUROCK Gypsum- Fiber Roof Board OB500 BP-AA or SBS-AA, SBS- TA or APP-TA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -52.5 LWC-10 Min. 22 ga., Type BV, Grade 33 steel, 6 ft span Min. 300 psi Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture One or more layer(s), min. 1.5-inch ACFoam II, ACFoam III, H-Shield or H-Shield CG Polyset BM Min. 0.25-inch SECUROCK Gypsum- Fiber Roof Board Polyset BM BP-AA or SBS-AA, SBS- TA or APP-TA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -52.5 LWC-11 Min. 22 ga., Type BV, Grade 33 steel, 6 ft span Min. 300 psi Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture One or more layer(s), min. 1.5-inch ACFoam II, ACFoam III, H-Shield or H-Shield CG Polyset CRA Min. 0.25-inch SECUROCK Gypsum- Fiber Roof Board Polyset CRA BP-AA or SBS-AA, SBS- TA or APP-TA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -52.5 ELASTIZELL (FL4994): COLD APPLIED SYSTEMS: LWC-12 Min. 22 ga., Type BV, Grade 33 steel, 5 ft span Min. 350 psi, min 2-inch Range II Elastizell with Zell-Crete Fibers. Min. 1.5-inch H-Shield CG OB500, 6- inch o.c. (Optional) Additional layers of base insulation OB500, 6-inch o.c. BP-CA3 or SBS-CA3 (Optional) BP- CA3 or SBS-CA3 SBS-CA3 -60.0 LWC-13 Min. 22 ga., Type BV, Grade 33 steel, 5 ft span Min. 350 psi, min 2-inch Range II Elastizell with Zell-Crete Fibers. When walkable, attach LWC with Trufast #14 HD with Trufast 3” Metal Insulation Plates at 1 per 8 ft2 through to the structural deck. Min. 1.5-inch H-Shield CG OB500, 6- inch o.c. (Optional) Additional layers of base insulation OB500, 6-inch o.c. BP-CA3 or SBS-CA3 (Optional) BP- CA3 or SBS-CA3 SBS-CA3 -67.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R29 for FL2533-R28 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 29: 04/14/2022 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 41 of 70 TABLE 4B: LIGHTWEIGHT CONCRETE OVER STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Lightweight Concrete (Note 14) Base Insulation Layer Coverboard Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Primer Base Ply Ply Cap Ply CELCORE (FL2037): SELF-ADHERING SYSTEMS: LWC-14 Structural concrete Min. 300 psi, min. 2-inch Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture; treated with Celcore PVA Curing Compound One or more layer(s), min. 1.5-inch ACFoam II, ACFoam III, H-Shield or H- Shield CG M-OSFA Min. 0.25-inch DensDeck M-OSFA FlintPrime QD SBS-SA (Optional) SBS-SA SBS-SA -90.0 LWC-15 Structural concrete Min. 300 psi, min. 2-inch Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture; treated with Celcore PVA Curing Compound One or more layer(s), min. 1.5-inch ACFoam II, ACFoam III, H-Shield or H- Shield CG M-OSFA Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board M-OSFA None SBS-SA (Optional) SBS-SA SBS-SA -90.0 LWC-16 Structural concrete Min. 300 psi, min. 2-inch Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture; treated with Celcore PVA Curing Compound and surfaced with Celcore Sanded Bonding Surface (SBS) One or more layer(s), min. 1.5-inch ACFoam II, ACFoam III, H-Shield or H- Shield CG M-OSFA Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board M-OSFA None SBS-SA (Optional) SBS-SA SBS-SA -172.5 LWC-17 Structural concrete Min. 300 psi, min. 2-inch Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture; treated with Celcore PVA Curing Compound and surfaced with Celcore Sanded Bonding Surface (SBS) One or more layer(s), min. 1.5-inch ACFoam II, ACFoam III, H-Shield or H- Shield CG M-OSFA Min. 0.25-inch DensDeck M-OSFA FlintPrime QD SBS-SA (Optional) SBS-SA SBS-SA -192.5 LWC-18 Structural concrete Min. 300 psi, min. 2-inch Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture; treated with Celcore PVA Curing Compound and surfaced with Celcore Sanded Bonding Surface (SBS) One or more layer(s), min. 1.5-inch ACFoam II, ACFoam III, H-Shield or H- Shield CG M-OSFA Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board M-OSFA FlintPrime QD SBS-SA (Optional) SBS-SA SBS-SA -217.5 LWC-19 Structural concrete Min. 300 psi, min. 2-inch Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture; treated with Celcore PVA Curing Compound One or more layer(s), min. 1.5-inch ACFoam II, ACFoam III, H-Shield or H- Shield CG M-PG1 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board M-PG1 None SBS-SA (Optional) SBS-SA SBS-SA -172.5 LWC-20 Structural concrete Min. 300 psi, min. 2-inch Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture; treated with Celcore PVA Curing Compound and surfaced with Celcore Sanded Bonding Surface (SBS) One or more layer(s), min. 1.5-inch ACFoam II, ACFoam III, H-Shield or H- Shield CG M-PG1 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board M-PG1 None SBS-SA (Optional) SBS-SA SBS-SA -172.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R29 for FL2533-R28 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 29: 04/14/2022 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 42 of 70 TABLE 4B: LIGHTWEIGHT CONCRETE OVER STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Lightweight Concrete (Note 14) Base Insulation Layer Coverboard Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Primer Base Ply Ply Cap Ply LWC-21 Structural concrete Min. 300 psi, min. 2-inch Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture; treated with Celcore PVA Curing Compound One or more layer(s), min. 1.5-inch ACFoam II, ACFoam III, H-Shield or H- Shield CG M-PG1 Min. 0.25-inch DensDeck M-PG1 FlintPrime QD SBS-SA (Optional) SBS-SA SBS-SA -192.5 LWC-22 Structural concrete Min. 300 psi, min. 2-inch Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture; treated with Celcore PVA Curing Compound and surfaced with Celcore Sanded Bonding Surface (SBS) One or more layer(s), min. 1.5-inch ACFoam II, ACFoam III, H-Shield or H- Shield CG M-PG1 Min. 0.25-inch DensDeck M-PG1 FlintPrime QD SBS-SA (Optional) SBS-SA SBS-SA -192.5 LWC-23 Structural concrete Min. 300 psi, min. 2-inch Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture; treated with Celcore PVA Curing Compound One or more layer(s), min. 1.5-inch ACFoam II, ACFoam III, H-Shield or H- Shield CG M-PG1 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board M-PG1 FlintPrime QD SBS-SA (Optional) SBS-SA SBS-SA -240.0 LWC-24 Structural concrete Min. 300 psi, min. 2-inch Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture; treated with Celcore PVA Curing Compound and surfaced with Celcore Sanded Bonding Surface (SBS) One or more layer(s), min. 1.5-inch ACFoam II, ACFoam III, H-Shield or H- Shield CG M-PG1 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board M-PG1 FlintPrime QD SBS-SA (Optional) SBS-SA SBS-SA -232.5 LWC-25 Structural concrete Min. 300 psi Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture One or more layer(s), min. 1.5-inch ACFoam II, ACFoam III, H-Shield or H- Shield CG OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 None SBS-SA (Optional) SBS-SA SBS-SA -172.5 LWC-26 Structural concrete Min. 200 psi, min. 2-inch Celcore Cellular Concrete Min. 1-inch ENRGY 3, H- Shield or H-Shield CG or min. 1.5-inch Multi-Max FA3 or Ultra-Max Polyset CRA Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Polyset CRA None SBS-SA (Optional) SBS-SA SBS-SA -172.5 LWC-27 Structural concrete Min. 300 psi Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture One or more layer(s), min. 1.5-inch ACFoam II, ACFoam III, H-Shield or H- Shield CG Polyset CRA Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Polyset CRA None SBS-SA (Optional) SBS-SA SBS-SA -172.5 LWC-28 Structural concrete Min. 200 psi, min. 2-inch Celcore Cellular Concrete Min. 1-inch ENRGY 3, H- Shield or H-Shield CG or min. 1.5-inch Multi-Max FA3 or Ultra-Max Polyset CRA Min. 0.25-inch DensDeck Polyset CRA FlintPrime QD SBS-SA (Optional) SBS-SA SBS-SA -180.0 HYBRID SYSTEMS: NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R29 for FL2533-R28 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 29: 04/14/2022 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 43 of 70 TABLE 4B: LIGHTWEIGHT CONCRETE OVER STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Lightweight Concrete (Note 14) Base Insulation Layer Coverboard Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Primer Base Ply Ply Cap Ply LWC-29 Structural concrete Min. 300 psi, min. 2-inch Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture; treated with Celcore PVA Curing Compound One or more layer(s), min. 1.5-inch ACFoam II or H- Shield M-OSFA (Optional) Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board M-OSFA None SBS-SA-H (Optional) SBS-AA, SBS- TA, APP-TA SBS-AA, SBS-TA, APP-TA -90.0 LWC-30 Structural concrete Min. 300 psi, min. 2-inch Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture; treated with Celcore PVA Curing Compound and surfaced with Celcore Sanded Bonding Surface (SBS) One or more layer(s), min. 1.5-inch ACFoam II or H- Shield M-OSFA (Optional) Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board M-OSFA None SBS-SA-H (Optional) SBS-AA, SBS- TA, APP-TA SBS-AA, SBS-TA, APP-TA -217.5 LWC-31 Structural concrete Min. 300 psi, min. 2-inch Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture; treated with Celcore PVA Curing Compound and surfaced with Celcore Sanded Bonding Surface (SBS) One or more layer(s), min. 1.5-inch ACFoam II or H- Shield M-PG1 (Optional) Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board M-PG1 None SBS-SA-H (Optional) SBS-AA, SBS- TA, APP-TA SBS-AA, SBS-TA, APP-TA -232.5 LWC-32 Structural concrete Min. 300 psi, min. 2-inch Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture; treated with Celcore PVA Curing Compound One or more layer(s), min. 1.5-inch ACFoam II or H- Shield M-PG1 (Optional) Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board M-PG1 None SBS-SA-H (Optional) SBS-AA, SBS- TA, APP-TA SBS-AA, SBS-TA, APP-TA -240.0 LWC-33 Structural concrete Min. 300 psi Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture One or more layer(s), min. 1.5-inch ACFoam II, ACFoam III, H-Shield or H- Shield CG OB500 (Optional) Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 None SBS-SA-H (Optional) SBS-AA, SBS- TA or APP-TA SBS-AA or APP- TA -215.0 LWC-34 Structural concrete Min. 300 psi Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture One or more layer(s), min. 1.5-inch ACFoam II, ACFoam III, H-Shield or H- Shield CG Polyset BM or Polyset CRA (Optional) Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Polyset BM or Polyset CRA None SBS-SA-H (Optional) SBS-AA, SBS- TA or APP-TA SBS-AA or APP- TA -215.0 CONVENTIONAL SYSTEMS: LWC-35 Structural concrete Min. 300 psi, min. 2-inch Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture; treated with Celcore PVA Curing Compound One or more layer(s), min. 1.5-inch ACFoam II, ACFoam III, H-Shield or H- Shield CG M-OSFA Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board M-OSFA None BP-AA, SBS- AA, SBS-TA or APP-TA (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP- TA -90.0 LWC-36 Structural concrete Min. 300 psi, min. 2-inch Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture; treated with Celcore PVA Curing Compound and surfaced with Celcore Sanded Bonding Surface (SBS) One or more layer(s), min. 1.5-inch ACFoam II, ACFoam III, H-Shield or H- Shield CG M-OSFA Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board M-OSFA None BP-AA, SBS- AA, SBS-TA or APP-TA (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP- TA -217.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R29 for FL2533-R28 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 29: 04/14/2022 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 44 of 70 TABLE 4B: LIGHTWEIGHT CONCRETE OVER STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Lightweight Concrete (Note 14) Base Insulation Layer Coverboard Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Primer Base Ply Ply Cap Ply LWC-37 Structural concrete Min. 300 psi, min. 2-inch Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture; treated with Celcore PVA Curing Compound One or more layer(s), min. 1.5-inch ACFoam II, ACFoam III, H-Shield or H- Shield CG M-PG1 Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board M-PG1 None BP-AA, SBS- AA, SBS-TA or APP-TA (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP- TA -240.0 LWC-38 Structural concrete Min. 300 psi, min. 2-inch Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture; treated with Celcore PVA Curing Compound and surfaced with Celcore Sanded Bonding Surface (SBS) One or more layer(s), min. 1.5-inch ACFoam II, ACFoam III, H-Shield or H- Shield CG M-PG1 Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board M-PG1 None BP-AA, SBS- AA, SBS-TA or APP-TA (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP- TA -232.5 LWC-39 Structural concrete Min. 300 psi Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture One or more layer(s), min. 1.5-inch ACFoam II, ACFoam III, H-Shield or H- Shield CG OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 None BP-AA, SBS-AA, SBS-TA or APP-TA (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP- TA -215.0 LWC-40 Structural concrete Min. 300 psi Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture One or more layer(s), min. 1.5-inch ACFoam II, ACFoam III, H-Shield or H- Shield CG Polyset BM Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Polyset BM None BP-AA, SBS-AA, SBS-TA or APP-TA (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP- TA -215.0 LWC-41 Structural concrete Min. 200 psi, min. 2-inch Celcore Cellular Concrete Min. 1-inch ENRGY 3, H- Shield or H-Shield CG or min. 1.5-inch Multi-Max FA3 or Ultra-Max Polyset CRA Min. 0.5-inch Structodek High Density Fiberboard Polyset CRA None BP-AA or SBS-AA (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP- TA -180.0 LWC-42 Structural concrete Min. 200 psi, min. 2-inch Celcore Cellular Concrete Min. 1-inch ENRGY 3, H- Shield or H-Shield CG or min. 1.5-inch Multi-Max FA3 or Ultra-Max Polyset CRA Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board or DensDeck or DensDeck Prime Polyset CRA None BP-AA, SBS- AA, SBS-TA or APP-TA (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP- TA -180.0 LWC-43 Structural concrete Min. 300 psi Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture One or more layer(s), min. 1.5-inch ACFoam II, ACFoam III, H-Shield or H- Shield CG Polyset CRA Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Polyset CRA None BP-AA, SBS-AA, SBS-TA or APP-TA (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP- TA -215.0 ELASTIZELL (FL4994): SELF-ADHERING SYSTEMS: LWC-44 Structural concrete Min. 200 psi, min. 2-inch Elastizell Min. 1.5-inch ACFoam II or ENRGY 3 OB500 Min. 0.25-inch DensDeck OB500 FlintPrime QD SBS-SA (Optional) SBS-SA SBS-SA -150.0 LWC-45 Structural concrete Min. 200 psi, min. 2-inch Elastizell Min. 1.5-inch ACFoam II, ENRGY 3 or H-Shield OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 None SBS-SA (Optional) SBS-SA SBS-SA -172.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R29 for FL2533-R28 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 29: 04/14/2022 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 45 of 70 TABLE 4B: LIGHTWEIGHT CONCRETE OVER STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Lightweight Concrete (Note 14) Base Insulation Layer Coverboard Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Primer Base Ply Ply Cap Ply LWC-46 Structural concrete Min. 200 psi, min. 2-inch Elastizell Min. 1-inch ENRGY 3, H- Shield or H-Shield CG or min. 1.5-inch Multi-Max FA3 or Ultra-Max Polyset CRA Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Polyset CRA None SBS-SA (Optional) SBS-SA SBS-SA -172.5 LWC-47 Structural concrete Min. 200 psi, min. 2-inch Elastizell Min. 1-inch ENRGY 3, H- Shield or H-Shield CG or min. 1.5-inch Multi-Max FA3 or Ultra-Max Polyset CRA Min. 0.25-inch DensDeck Polyset CRA FlintPrime QD SBS-SA (Optional) SBS-SA SBS-SA -180.0 CONVENTIONAL SYSTEMS: LWC-48 Structural concrete Min. 200 psi, min. 2-inch Elastizell Min. 1.5-inch ACFoam II OB500 Min. 0.25-inch DensDeck or DensDeck Prime OB500 None BP-AA, SBS- AA, SBS-TA or APP-TA (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP- TA -150.0 LWC-49 Structural concrete Min. 200 psi, min. 2-inch Elastizell Min. 2-inch ACFoam II, ENRGY 3 or H-Shield OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 None BP-AA, SBS-AA, SBS-TA or APP-TA (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP- TA -225.0 LWC-50 Structural concrete Min. 200 psi, min. 2-inch Elastizell Min. 1-inch ENRGY 3, H- Shield or H-Shield CG or min. 1.5-inch Multi-Max FA3 or Ultra-Max Polyset CRA Min. 0.5-inch Structodek High Density Fiberboard Polyset CRA None BP-AA or SBS-AA (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP- TA -180.0 LWC-51 Structural concrete Min. 200 psi, min. 2-inch Elastizell Min. 1-inch ENRGY 3, H- Shield or H-Shield CG or min. 1.5-inch Multi-Max FA3 or Ultra-Max Polyset CRA Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board or DensDeck or DensDeck Prime Polyset CRA None BP-AA, SBS- AA, SBS-TA or APP-TA (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP- TA -180.0 COLD APPLIED SYSTEMS: LWC-52 Structural concrete Min. 350 psi, min 2-inch Elastizell with Zell-Crete Fibers. Min. 1.5-inch H-Shield CG OB500, 6- inch o.c. (Optional) Additional layers of base insulation OB500, 6-inch o.c. None BP-CA3 or SBS-CA3 (Optional) BP-CA3 or SBS-CA3 SBS-CA3 -60.0 LWC-53 Structural concrete Min. 350 psi, min 2-inch Range II Elastizell with Zell-Crete Fibers. When walkable, attach LWC with Trufast #14HD with Trufast 3” Metal Insulation Plates at 1 per 8 ft2 through to the structural deck. Min. 1.5-inch H-Shield CG OB500, 6- inch o.c. (Optional) Additional layers of base insulation OB500, 6-inch o.c. None BP-CA3 or SBS-CA3 (Optional) BP-CA3 or SBS-CA3 SBS-CA3 -67.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R29 for FL2533-R28 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 29: 04/14/2022 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 46 of 70 TABLE 4C: LIGHTWEIGHT INSULATING CONCRETE OVER STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: LWC TO DECK, BONDED VAPOR BARRIER, BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Lightweight Concrete (Note 14) Vapor Barrier Base Insulation Layer Coverboard Primer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6&7) Type Attach (Notes 6&7) Base Ply Ply Cap Ply PRE-EXISTENT CELLULAR LWC: SELF-ADHERING SYSTEMS: LWC-54 Min. 22 ga., Type BV, Grade 40 steel Min. 400 psi, Min. 2- inch, pre-existent cellular lightweight concrete, Repair LWC spalls with Celcore SBS (Sanded Bonding Surface) Flintlastic Ultra Poly SMS Base Sheet applied in HB Fuller “Millennium Hurricane Force Membrane Adhesive HS”, ribbons max. 6-inch o.c. 3-inch wide side laps and 6-inch wide end laps are hot-air-welded, torch-welded or sealed with HB Fuller “Millennium Hurricane Force Lap and Flashing Adhesive” One or more layers, min. 2-inch ACFoam II or H-Shield M-OSFA or M-PG1 (Optional) 0.5- in. DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board M-OSFA or M-PG1 FlintPrime QD SBS-SA (Optional) SBS-SA SBS-SA -67.5 HYBRID SYSTEMS: LWC-55 Min. 22 ga., Type BV, Grade 40 steel Min. 400 psi, Min. 2- inch, pre-existent cellular lightweight concrete, Repair LWC spalls with Celcore SBS (Sanded Bonding Surface) Flintlastic Ultra Poly SMS Base Sheet applied in HB Fuller “Millennium Hurricane Force Membrane Adhesive HS”, ribbons max. 6-inch o.c. 3-inch wide side laps and 6-inch wide end laps are hot-air-welded, torch-welded or sealed with HB Fuller “Millennium Hurricane Force Lap and Flashing Adhesive” One or more layers, min. 2-inch ACFoam II or H-Shield M-OSFA or M-PG1 0.5-in. DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board M-OSFA or M-PG1 (Optional) FlintPrime QD SBS-SA-H (Optional) SBS-TA or APP-TA APP-TA -67.5 CONVENTIONAL SYSTEMS: LWC-56 Min. 22 ga., Type BV, Grade 40 steel Min. 400 psi, Min. 2- inch, pre-existent cellular lightweight concrete, Repair LWC spalls with Celcore SBS (Sanded Bonding Surface) Flintlastic Ultra Poly SMS Base Sheet applied in HB Fuller “Millennium Hurricane Force Membrane Adhesive HS”, ribbons max. 6-inch o.c. 3-inch wide side laps and 6-inch wide end laps are hot-air-welded, torch-welded or sealed with HB Fuller “Millennium Hurricane Force Lap and Flashing Adhesive” One or more layers, min. 2-inch ACFoam II or H-Shield M-OSFA or M-PG1 0.5-in. DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board M-OSFA or M-PG1 (Optional) FlintPrime QD SBS-TA or APP-TA (Optional) SBS-TA or APP-TA APP-TA -67.5 ELASTIZELL (FL4994): SELF-ADHERING SYSTEMS: LWC-57 Structural Concrete Min. 420 psi, min. 2-inch Elastizell All Weather/Empire Base Sheet or Flintglas MS Cap (inverted) applied in HB Fuller “Millennium Hurricane Force Membrane Adhesive HS”, ribbons max. 6- inch o.c., 3-inch wide side laps and 6-inch wide end laps are sealed with HB Fuller “Millennium Hurricane Force Lap and Flashing Adhesive” One or more layers, min. 2-inch ACFoam II or H-Shield M-OSFA or M-PG1 (Optional) 0.5- in. DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board M-OSFA or M-PG1 FlintPrime QD SBS-SA (Optional) SBS-SA SBS-SA -67.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R29 for FL2533-R28 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 29: 04/14/2022 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 47 of 70 TABLE 4C: LIGHTWEIGHT INSULATING CONCRETE OVER STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: LWC TO DECK, BONDED VAPOR BARRIER, BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Lightweight Concrete (Note 14) Vapor Barrier Base Insulation Layer Coverboard Primer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6&7) Type Attach (Notes 6&7) Base Ply Ply Cap Ply LWC-58 Structural Concrete Min. 420 psi, min. 2-inch Elastizell Flintlastic Ultra Poly SMS Base Sheet applied in HB Fuller “Millennium Hurricane Force Membrane Adhesive HS”, ribbons max. 6-inch o.c., 3-inch wide side laps and 6-inch wide end laps are hot-air-welded, torch-welded or sealed with HB Fuller “Millennium Hurricane Force Lap and Flashing Adhesive” One or more layers, min. 2-inch ACFoam II or H-Shield M-OSFA or M-PG1 (Optional) 0.5- in. DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board M-OSFA or M-PG1 FlintPrime QD SBS-SA (Optional) SBS-SA SBS-SA -67.5 HYBRID SYSTEMS: LWC-59 Structural Concrete Min. 420 psi, min. 2-inch Elastizell All Weather/Empire Base Sheet or Flintglas MS Cap (inverted) applied in HB Fuller “Millennium Hurricane Force Membrane Adhesive HS”, ribbons max. 6- inch o.c., 3-inch wide side laps and 6-inch wide end laps are sealed with HB Fuller “Millennium Hurricane Force Lap and Flashing Adhesive” One or more layers, min. 2-inch ACFoam II or H-Shield M-OSFA or M-PG1 0.5-in. DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board M-OSFA or M-PG1 (Optional) FlintPrime QD SBS-SA-H (Optional) SBS-TA or APP-TA APP-TA -67.5 LWC-60 Structural Concrete Min. 420 psi, min. 2-inch Elastizell Flintlastic Ultra Poly SMS Base Sheet applied in HB Fuller “Millennium Hurricane Force Membrane Adhesive HS”, ribbons max. 6-inch o.c., 3-inch wide side laps and 6-inch wide end laps are hot-air-welded, torch-welded or sealed with HB Fuller “Millennium Hurricane Force Lap and Flashing Adhesive” One or more layers, min. 2-inch ACFoam II or H-Shield M-OSFA or M-PG1 0.5-in. DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board M-OSFA or M-PG1 (Optional) FlintPrime QD SBS-SA-H (Optional) SBS-TA or APP-TA APP-TA -67.5 CONVENTIONAL SYSTEMS: LWC-61 Structural Concrete Min. 420 psi, min. 2-inch Elastizell All Weather/Empire Base Sheet or Flintglas MS Cap (inverted) applied in HB Fuller “Millennium Hurricane Force Membrane Adhesive HS”, ribbons max. 6- inch o.c., 3-inch wide side laps and 6-inch wide end laps are sealed with HB Fuller “Millennium Hurricane Force Lap and Flashing Adhesive” One or more layers, min. 2-inch ACFoam II or H-Shield M-OSFA or M-PG1 0.5-in. DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board M-OSFA or M-PG1 (Optional) FlintPrime QD SBS-TA or APP-TA (Optional) SBS-TA or APP-TA APP-TA -67.5 LWC-62 Structural Concrete Min. 420 psi, min. 2-inch Elastizell Flintlastic Ultra Poly SMS Base Sheet applied in HB Fuller “Millennium Hurricane Force Membrane Adhesive HS”, ribbons max. 6-inch o.c., 3-inch wide side laps and 6-inch wide end laps are hot-air-welded, torch-welded or sealed with HB Fuller “Millennium Hurricane Force Lap and Flashing Adhesive” One or more layers, min. 2-inch ACFoam II or H-Shield M-OSFA or M-PG1 0.5-in. DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board M-OSFA or M-PG1 (Optional) FlintPrime QD SBS-TA or APP-TA (Optional) SBS-TA or APP-TA APP-TA -67.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R29 for FL2533-R28 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 29: 04/14/2022 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 48 of 70 TABLE 4D: LIGHTWEIGHT CONCRETE OVER STEEL DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Lightweight Concrete (Note 14) Anchor Sheet Insulation Roof Cover (Note 15) MDP (psf) Deck Treatment Type Surface Treatment Type Fasteners Attach Base Top Attach Base Ply Ply Cap Ply PRE-EXISTENT CELLULAR LWC: SPOT- OR STRIP-MOPPED SYSTEMS: LWC-63 Min. 22 ga. steel or structural concrete deck. None Min 350 psi, min 2-inch pre- existent cellular LWIC None Flintglas MS Cap (inverted) Trufast Twin- Loc Nails 9-inch o.c. at the 4-inch side lap and 9-inch o.c. at two, equally spaced, staggered rows in the center of the sheet Min. 1.5- inch ACFoam II (Optional) Additional layers base insulation Hot asphalt BP-AA4, 18-inch o.c. (Optional) BP-AA, SBS- AA SBS-AA -60.0 Note: To qualify the LWIC under this assembly, the subject fastener shall achieve an average withdrawal of 88 lbf when tested per ANSI/SPRI FX-1 or TAS 105. CELCORE (FL2037): SELF-ADHERING SYSTEMS: LWC-64 Min. 22 ga., type BV, Grade 40 steel, 6 ft span Celcore S-1 Deck Preparation Min. 470 psi, min. 2-inch Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture Celcore PVA Curing Compound All Weather/Empire Base Sheet, Glasbase Base Sheet or Flintlastic Base 20 or Flintglas MS Cap (inverted) Trufast FM- 90 Base Sheet Fasteners 7-inch o.c. at the min. 4-inch side laps and 7-inch o.c. at two, equally spaced, staggered center rows Min. 1.5" ACFoam II (Optional) Min. 0.25- inch DensDeck Prime or SECUROCK Gypsum- Fiber Roof Board. Top surface shall be primed with FlintPrime QD. hot asphalt SBA-SA (Optional) SBS-SA SBS-SA -60.0 HYBRID SYSTEMS: LWC-65 Min. 22 ga., type BV, Grade 40 steel, 6 ft span Celcore S-1 Deck Preparation Min. 470 psi, min. 2-inch Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture Celcore PVA Curing Compound All Weather/Empire Base Sheet, Glasbase Base Sheet or Flintlastic Base 20 or Flintglas MS Cap (inverted) Trufast FM- 90 Base Sheet Fasteners 7-inch o.c. at the min. 4-inch side laps and 7-inch o.c. at two, equally spaced, staggered center rows Min. 1.5" ACFoam II (Optional) Min. 0.125- inch STURDY-DEK Asphaltic Cover Board or min. 0.25-inch DensDeck Prime or SECUROCK Gypsum- Fiber Roof Board. Top surface may be optionally primed with FlintPrime QD. hot asphalt SBS-SA-H (Optional) SBS-AA, SBS-TA or APP-TA SBS-AA or APP- TA -60.0 CONVENTIONAL SYSTEMS: NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R29 for FL2533-R28 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 29: 04/14/2022 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 49 of 70 TABLE 4D: LIGHTWEIGHT CONCRETE OVER STEEL DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Lightweight Concrete (Note 14) Anchor Sheet Insulation Roof Cover (Note 15) MDP (psf) Deck Treatment Type Surface Treatment Type Fasteners Attach Base Top Attach Base Ply Ply Cap Ply LWC-66 Min. 22 ga., type BV, Grade 40 steel, 6 ft span Celcore S-1 Deck Preparation Min. 470 psi, min. 2-inch Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture Celcore PVA Curing Compound All Weather/Empire Base Sheet, Glasbase Base Sheet or Flintlastic Base 20 or Flintglas MS Cap (inverted) Trufast FM- 90 Base Sheet Fasteners 7-inch o.c. at the min. 4-inch side laps and 7-inch o.c. at two, equally spaced, staggered center rows Min. 1.5" ACFoam II Min. 0.125-inch STURDY-DEK Asphaltic Cover Board, min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board, min. 0.5-inch Structodek High Density Fiberboard Roof Insulation or min. 0.75-inch Fesco Board (homogeneous) hot asphalt BP-AA or SBS-AA (Optional) SBS-AA, SBS-TA or APP-TA SBS-AA or APP- TA -60.0 LWC-67 Min. 22 ga., type BV, Grade 40 steel, 6 ft span Celcore S-1 Deck Preparation Min. 470 psi, min. 2-inch Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture Celcore PVA Curing Compound All Weather/Empire Base Sheet, Glasbase Base Sheet or Flintlastic Base 20 or Flintglas MS Cap (inverted) Trufast FM- 90 Base Sheet Fasteners 7-inch o.c. at the min. 4-inch side laps and 7-inch o.c. at two, equally spaced, staggered center rows Min. 1.5" ACFoam II Min. 0.125-inch STURDY-DEK Asphaltic Cover Board or min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board. Top surface may be optionally primed with FlintPrime QD. hot asphalt SBS-TA or APP-TA (Optional) SBS-TA or APP-TA APP-TA -60.0 ELASTIZELL (FL4994): SELF-ADHERING SYSTEMS: LWC-68 Min. 22 ga., type BV, Grade 40 steel, 6 ft span None Min. 490 psi, min. 2-inch Elastizell with Zell-Crete Fibers None All Weather/Empire Base Sheet, Glasbase Base Sheet or Flintlastic Base 20 or Flintglas MS Cap (inverted) Trufast FM- 90 Base Sheet Fasteners 7-inch o.c. at the min. 4-inch side laps and 7-inch o.c. at two, equally spaced, staggered center rows Min. 1.5" ACFoam II (Optional) Min. 0.25- inch DensDeck Prime or SECUROCK Gypsum- Fiber Roof Board. Top surface shall be primed with FlintPrime QD. hot asphalt SBA-SA (Optional) SBS-SA SBS-SA -67.5 HYBRID SYSTEMS: LWC-69 Min. 22 ga., type BV, Grade 40 steel, 6 ft span None Min. 490 psi, min. 2-inch Elastizell with Zell-Crete Fibers None All Weather/Empire Base Sheet, Glasbase Base Sheet or Flintlastic Base 20 or Flintglas MS Cap (inverted) Trufast FM- 90 Base Sheet Fasteners 7-inch o.c. at the min. 4-inch side laps and 7-inch o.c. at two, equally spaced, staggered center rows Min. 1.5" ACFoam II (Optional) Min. 0.125- inch STURDY-DEK Asphaltic Cover Board or min. 0.25-inch DensDeck Prime or SECUROCK Gypsum- Fiber Roof Board. Top surface may be optionally primed with FlintPrime QD. hot asphalt SBS-SA-H (Optional) SBS-AA, SBS-TA or APP-TA SBS-AA or APP- TA -67.5 CONVENTIONAL SYSTEMS: NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R29 for FL2533-R28 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 29: 04/14/2022 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 50 of 70 TABLE 4D: LIGHTWEIGHT CONCRETE OVER STEEL DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Lightweight Concrete (Note 14) Anchor Sheet Insulation Roof Cover (Note 15) MDP (psf) Deck Treatment Type Surface Treatment Type Fasteners Attach Base Top Attach Base Ply Ply Cap Ply LWC-70 Min. 22 ga., type BV, Grade 40 steel, 6 ft span None Min. 490 psi, min. 2-inch Elastizell with Zell-Crete Fibers None All Weather/Empire Base Sheet, Glasbase Base Sheet or Flintlastic Base 20 or Flintglas MS Cap (inverted) Trufast FM- 90 Base Sheet Fasteners 7-inch o.c. at the min. 4-inch side laps and 7-inch o.c. at two, equally spaced, staggered center rows Min. 1.5" ACFoam II Min. 0.125-inch STURDY-DEK Asphaltic Cover Board, min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board, min. 0.5-inch Structodek High Density Fiberboard Roof Insulation or min. 0.75-inch Fesco Board (homogeneous) hot asphalt BP-AA or SBS-AA (Optional) SBS-AA, SBS-TA or APP-TA SBS-AA or APP- TA -67.5 LWC-71 Min. 22 ga., type BV, Grade 40 steel, 6 ft span None Min. 490 psi, min. 2-inch Elastizell with Zell-Crete Fibers None All Weather/Empire Base Sheet, Glasbase Base Sheet or Flintlastic Base 20 or Flintglas MS Cap (inverted) Trufast FM- 90 Base Sheet Fasteners 7-inch o.c. at the min. 4-inch side laps and 7-inch o.c. at two, equally spaced, staggered center rows Min. 1.5" ACFoam II Min. 0.125-inch STURDY-DEK Asphaltic Cover Board or min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board. Top surface may be optionally primed with FlintPrime QD. hot asphalt SBS-TA or APP-TA (Optional) SBS-TA or APP-TA APP-TA -67.5 SPOT- OR STRIP-MOPPED SYSTEMS: LWC-72 Min. 22 ga. steel or structural concrete deck. None Min 350 psi, min 2-inch Elastizell cellular LWIC None Flintglas MS Cap (inverted) Trufast FM- 90 Base Ply Fasteners 7-inch o.c. at the 4-inch side lap and 7-inch o.c. at two, equally spaced, staggered rows in the center of the sheet Min. 1.5- inch ACFoam II (Optional) Additional layers base insulation Hot asphalt BP-AA3, 18-inch grid (Optional) BP-AA, SBS- AA SBS-AA -37.5* NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R29 for FL2533-R28 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 29: 04/14/2022 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 51 of 70 TABLE 4E: LIGHTWEIGHT CONCRETE DECKS OVER STEEL OR STRUCTURAL CONCRETE DECK – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE E-2: MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Lightweight Concrete (Note 14) Base Sheet Roof Cover (Note 15) MDP (psf) Deck Treatment LWC Surface Treatment Type Fasteners Attach Base Ply Cap Ply PRE-EXISTENT CELLULAR LIGHTWEIGHT CONCRETE: SELF-ADHERING SYSTEMS: LWC-73 Min. 22 ga., Type BV, Grade 33 steel, 5 ft span or structural concrete None Min. 300 psi, min. 2- inch pre-existent cellular lightweight insulating concrete. None Flintlastic SA NailBase Trufast Twin Loc- Nail Assembled Fastener (min. 1.8”) 7-inch o.c. at the min. 2-inch lap and 7-inch o.c. in two (2), equally spaced, staggered center rows, FlintPrime QD at stress plates SBS-SA SBS-SA -60.0 Note: To qualify the LWIC under this assembly, a 1.8-inch Trufast Twin Loc-Nail Assembled Fastener shall achieve an average withdrawal of 73 lbf when tested per ANSI/SPRI FX-1 or TAS 105 LWC-74 Min. 22 ga., Type BV, Grade 33 steel, 5 ft span or structural concrete None Min. 300 psi, min. 2- inch pre-existent cellular lightweight insulating concrete. None Flintlastic SA NailBase Trufast Twin Loc- Nail Assembled Fastener (min. 1.8”) 9-inch o.c. at the min. 2-inch lap and 9-inch o.c. in two (2), equally spaced, staggered center rows, FlintPrime QD at stress plates SBS-SA SBS-SA -60.0 Note: To qualify the LWIC under this assembly, a 1.8-inch Trufast Twin Loc-Nail Assembled Fastener shall achieve an average withdrawal of 93 lbf when tested per ANSI/SPRI FX-1 or TAS 105 HYBRID SYSTEMS: LWC-75 Min. 22 ga., Type BV, Grade 33 steel, 5 ft span or structural concrete None Min. 300 psi, min. 2- inch pre-existent cellular lightweight insulating concrete. None Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet Trufast Twin Loc- Nail Assembled Fastener (min. 1.8”) 9-inch o.c. at the 4-inch lap and 9- inch o.c. in two (2), equally spaced, staggered center rows SBS-SA-H SBS-AA or APP- TA -60.0 Note: To qualify the LWIC under this assembly, a 1.8-inch Trufast Twin Loc-Nail Assembled Fastener shall achieve an average withdrawal of 88 lbf when tested per ANSI/SPRI FX-1 or TAS 105 LWC-76 Min. 22 ga., Type BV, Grade 33 steel, 5 ft span or structural concrete None Min. 350 psi, min. 3- inch pre-existent cellular lightweight insulating concrete. None Flintlastic Base 20 or Flintlastic Poly SMS Base Sheet Trufast FM-90 Base Sheet Fasteners 7-inch o.c. at the 4-inch lap and 10- inch o.c. in two (2), equally spaced, staggered center rows SBS-SA-H SBS-AA or APP- TA -67.5 Note: To qualify the LWIC under this assembly, a 1.8-inch Trufast Twin Loc-Nail Assembled Fastener shall achieve an average withdrawal of 97 lbf when tested per ANSI/SPRI FX-1 or TAS 105 LWC-77 Min. 22 ga., Type BV, Grade 33 steel, 5 ft span or structural concrete None Min. 300 psi, min. 2- inch pre-existent cellular lightweight insulating concrete. None Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet Trufast Twin Loc- Nail Assembled Fastener (min. 1.8”) 9-inch o.c. at the 4-inch lap and 9- inch o.c. in two (2), equally spaced, staggered center rows SBS-SA-H SBS-AA or APP- TA -75.0 Note: To qualify the LWIC under this assembly, a 1.8-inch Trufast Twin Loc-Nail Assembled Fastener shall achieve an average withdrawal of 110 lbf when tested per ANSI/SPRI FX-1 or TAS 105 CONVENTIONAL SYSTEMS: NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R29 for FL2533-R28 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 29: 04/14/2022 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 52 of 70 TABLE 4E: LIGHTWEIGHT CONCRETE DECKS OVER STEEL OR STRUCTURAL CONCRETE DECK – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE E-2: MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Lightweight Concrete (Note 14) Base Sheet Roof Cover (Note 15) MDP (psf) Deck Treatment LWC Surface Treatment Type Fasteners Attach Base Ply Cap Ply LWC-78 Min. 22 ga., Type BV, Grade 33 steel, 5 ft span or structural concrete None Min. 300 psi, min. 2- inch pre-existent cellular lightweight insulating concrete. None Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet or Flintglas MS Cap (inverted) Trufast Twin Loc- Nail Assembled Fastener (min. 1.8”) 9-inch o.c. at the 4-inch lap and 9- inch o.c. in two (2), equally spaced, staggered center rows (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP- TA -60.0 Note: To qualify the LWIC under this assembly, a 1.8-inch Trufast Twin Loc-Nail Assembled Fastener shall achieve an average withdrawal of 88 lbf when tested per ANSI/SPRI FX-1 or TAS 105 LWC-79 Min. 22 ga., Type BV, Grade 33 steel, 5 ft span or structural concrete None Min. 300 psi, min. 2- inch pre-existent cellular lightweight insulating concrete. None Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet or Flintglas MS Cap (inverted) Trufast Twin Loc- Nail Assembled Fastener (min. 1.8”) 7-inch o.c. at the 4-inch lap and 7- inch o.c. in two (2), equally spaced, staggered center rows BP-AA or SBS-AA SBS-AA or APP- TA -67.5 Note: To qualify the LWIC under this assembly, a 1.8-inch Trufast Twin Loc-Nail Assembled Fastener shall achieve an average withdrawal of 77 lbf when tested per ANSI/SPRI FX-1 or TAS 105 LWC-80 Min. 22 ga., Type BV, Grade 33 steel, 5 ft span or structural concrete None Min. 350 psi, min. 3- inch pre-existent cellular lightweight insulating concrete. None Flintlastic Base 20, Flintlastic Poly SMS Base Sheet or Flintglas MS Cap (inverted) Trufast FM-90 Base Sheet Fasteners 7-inch o.c. at the 4-inch lap and 10- inch o.c. in two (2), equally spaced, staggered center rows BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP- TA -67.5 Note: To qualify the LWIC under this assembly, a 1.8-inch Trufast Twin Loc-Nail Assembled Fastener shall achieve an average withdrawal of 97 lbf when tested per ANSI/SPRI FX-1 or TAS 105 LWC-81 Min. 22 ga., Type BV, Grade 33 steel, 5 ft span or structural concrete None Min. 300 psi, min. 2- inch pre-existent cellular lightweight insulating concrete. None Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet Trufast Twin Loc- Nail Assembled Fastener (min. 1.8”) 9-inch o.c. at the 4-inch lap and 9- inch o.c. in two (2), equally spaced, staggered center rows BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP- TA -75.0 Note: To qualify the LWIC under this assembly, a 1.8-inch Trufast Twin Loc-Nail Assembled Fastener shall achieve an average withdrawal of 110 lbf when tested per ANSI/SPRI FX-1 or TAS 105 CELCORE (FL2037): SELF-ADHERING SYSTEMS: LWC-82 Min. 22 ga., type BV, Grade 40 steel, 6 ft span Celcore S-1 Deck Preparation Min. 470 psi, min. 2- inch Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture Celcore PVA Curing Compound Flintlastic SA NailBase Trufast FM-90 Base Sheet Fasteners 7-inch o.c. at the min. 4-inch side laps and 7-inch o.c. at two, equally spaced, staggered center rows SBS-SA SBS-SA -45.0 HYBRID SYSTEMS: LWC-83 Min. 22 ga., type BV, Grade 40 steel, 6 ft span Celcore S-1 Deck Preparation Min. 470 psi, min. 2- inch Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture Celcore PVA Curing Compound All Weather/Empire Base Sheet, Glasbase Base Sheet or Flintlastic Base 20 Trufast FM-90 Base Sheet Fasteners 7-inch o.c. at the min. 4-inch side laps and 7-inch o.c. at two, equally spaced, staggered center rows SBS-SA-H SBS-AA or APP- TA -45.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R29 for FL2533-R28 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 29: 04/14/2022 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 53 of 70 TABLE 4E: LIGHTWEIGHT CONCRETE DECKS OVER STEEL OR STRUCTURAL CONCRETE DECK – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE E-2: MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Lightweight Concrete (Note 14) Base Sheet Roof Cover (Note 15) MDP (psf) Deck Treatment LWC Surface Treatment Type Fasteners Attach Base Ply Cap Ply LWC-84 Min. 22 ga., type BV, Grade 40 steel, 6 ft span Celcore S-1 Deck Preparation Min. 470 psi, min. 2- inch Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture Celcore PVA Curing Compound Flintglas MS Cap (inverted) primed with FlintPrime QD Trufast FM-90 Base Sheet Fasteners 7-inch o.c. at the min. 4-inch side laps and 7-inch o.c. at two, equally spaced, staggered center rows SBS-SA-H SBS-AA or APP- TA -45.0 CONVENTIONAL SYSTEMS: LWC-85 Min. 22 ga., type BV, Grade 40 steel, 6 ft span Celcore S-1 Deck Preparation Min. 470 psi, min. 2- inch Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture Celcore PVA Curing Compound All Weather/Empire Base Sheet, Glasbase Base Sheet or Flintlastic Base 20 or Flintglas MS Cap (inverted) Trufast FM-90 Base Sheet Fasteners 7-inch o.c. at the min. 4-inch side laps and 7-inch o.c. at two, equally spaced, staggered center rows (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP- TA -45.0 LWC-86 Min. 22 ga., type B steel at max. 5 ft spans structural concrete None Min. 300 psi, min 2- inch Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture. Celcore PVA Curing Compound All Weather/Empire Base Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet Trufast FM-90 Base Sheet Fasteners 9-inch o.c. at 4-inch laps and 12-inch o.c. in two (2), equally spaced, staggered center rows (Optional) BP-AA, SBS- AA or SBS- TA SBS-AA -60.0 LWC-87 Min. 22 ga., Type BV, Grade 33 steel, 5 ft span or structural concrete None Min. 300 psi, min 2- inch Celcore Cellular Concrete. Celcore PVA Curing Compound Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet, Flintlastic Poly SMS Base Sheet or Flintglas MS Cap (inverted) Trufast FM-90 Base Sheet Fasteners 7-inch o.c. at the 3-inch lap and 7- inch o.c. in two (2), equally spaced, staggered center rows BP-AA or SBS-AA SBS-AA or APP- TA -75.0 CONCRECEL (FL5584 & FL10500): CONVENTIONAL SYSTEMS: LWC-88 Min. 22 ga., Type BV, Grade 33 steel, 5 ft span or structural concrete Concrecel Bonding Agent Min. 300 psi, min 2¼- inch Concrecel Concrete. Concrecel Curing Compound Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet, Flintlastic Poly SMS Base Sheet or Flintglas MS Cap (inverted) OMG CR Base Ply Fasteners (1.7) 7-inch o.c. at the 3-inch lap and 7- inch o.c. in two (2), equally spaced, staggered center rows (Optional) BP-AA or SBS-AA SBS-AA or APP- TA -52.5 ELASTIZELL (FL4994): SELF-ADHERING SYSTEMS: LWC-89 Min. 22 ga., type BV, Grade 40 steel, 6 ft span None Min. 490 psi, min. 2- inch Elastizell with Zell-Crete Fibers None Flintlastic SA NailBase Trufast FM-90 Base Sheet Fasteners 7-inch o.c. at the min. 4-inch side laps and 7-inch o.c. at two, equally spaced, staggered center rows SBS-SA SBS-SA -45.0 HYBRID SYSTEMS: NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R29 for FL2533-R28 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 29: 04/14/2022 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 54 of 70 TABLE 4E: LIGHTWEIGHT CONCRETE DECKS OVER STEEL OR STRUCTURAL CONCRETE DECK – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE E-2: MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Lightweight Concrete (Note 14) Base Sheet Roof Cover (Note 15) MDP (psf) Deck Treatment LWC Surface Treatment Type Fasteners Attach Base Ply Cap Ply LWC-90 Min. 26 ga. steel at max 5 ft spans or structural concrete None Min. 200 psi, min 2- inch Elastizell. None Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet or Flintlastic Poly SMS Base Sheet Trufast FM-90 Base Sheet Fasteners or Trufast Twin Loc-Nail Assembled Fasteners (1.8 inch) 7½-inch o.c. at the 4-inch lap and 7½-inch o.c. in two (2), equally spaced, staggered center rows SBS-SA-H SBS-AA or APP- TA -30.0 LWC-91 Min. 22 ga., Type BV, Grade 33 steel, 5 ft span or structural concrete None Min. 200 psi, min 2- inch Elastizell. None Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet or Flintlastic Poly SMS Base Sheet Trufast FM-90 Base Sheet Fasteners or Trufast Twin Loc-Nail Assembled Fasteners (1.8 inch) 7-inch o.c. at the 4-inch lap and 7- inch o.c. in two (2), equally spaced, staggered center rows SBS-SA-H SBS-AA or APP- TA -45.0 LWC-92 Min. 22 ga., type BV, Grade 40 steel, 6 ft span None Min. 490 psi, min. 2- inch Elastizell with Zell-Crete Fibers None All Weather/Empire Base Sheet, Glasbase Base Sheet or Flintlastic Base 20 Trufast FM-90 Base Sheet Fasteners 7-inch o.c. at the min. 4-inch side laps and 7-inch o.c. at two, equally spaced, staggered center rows SBS-SA-H SBS-AA or APP- TA -45.0 LWC-93 Min. 22 ga., type BV, Grade 40 steel, 6 ft span None Min. 490 psi, min. 2- inch Elastizell with Zell-Crete Fibers None Flintglas MS Cap (inverted) primed with FlintPrime QD Trufast FM-90 Base Sheet Fasteners 7-inch o.c. at the min. 4-inch side laps and 7-inch o.c. at two, equally spaced, staggered center rows SBS-SA-H SBS-AA or APP- TA -45.0 CONVENTIONAL SYSTEMS: LWC-94 Min. 26 ga. steel at max 5 ft spans or structural concrete None Min. 200 psi, min 2- inch Elastizell. None Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet, Flintlastic Poly SMS Base Sheet or Flintglas MS Cap (inverted) Trufast FM-90 Base Sheet Fasteners or Trufast Twin Loc-Nail Assembled Fasteners (1.8 inch) 7½-inch o.c. at the 4-inch lap and 7½-inch o.c. in two (2), equally spaced, staggered center rows (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP- TA -30.0 LWC-95 Min. 26 ga. steel at max 5 ft spans or structural concrete None Min. 200 psi, min 2- inch Elastizell. None Flintlastic APP Base T Trufast FM-90 Base Sheet Fasteners 7½-inch o.c. at the 4-inch lap and 7½-inch o.c. in two (2), equally spaced, staggered center rows (Optional) APP-TA APP-TA -30.0 LWC-96 Min. 22 ga., type BV, Grade 40 steel, 6 ft span None Min. 490 psi, min. 2- inch Elastizell with Zell-Crete Fibers None All Weather/Empire Base Sheet, Glasbase Base Sheet or Flintlastic Base 20 or Flintglas MS Cap (inverted) Trufast FM-90 Base Sheet Fasteners 7-inch o.c. at the min. 4-inch side laps and 7-inch o.c. at two, equally spaced, staggered center rows (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP- TA -45.0 LWC-97 Min. 22 ga., Type BV, Grade 33 steel, 5 ft span or structural concrete None Min. 200 psi, min 2- inch Elastizell. None Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet, Flintlastic Poly SMS Base Sheet or Flintglas MS Cap (inverted) Trufast FM-90 Base Sheet Fasteners or Trufast Twin Loc-Nail Assembled Fasteners (1.8 inch) 7-inch o.c. at the 4-inch lap and 7- inch o.c. in two (2), equally spaced, staggered center rows (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP- TA -45.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R29 for FL2533-R28 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 29: 04/14/2022 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 55 of 70 TABLE 4E: LIGHTWEIGHT CONCRETE DECKS OVER STEEL OR STRUCTURAL CONCRETE DECK – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE E-2: MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Lightweight Concrete (Note 14) Base Sheet Roof Cover (Note 15) MDP (psf) Deck Treatment LWC Surface Treatment Type Fasteners Attach Base Ply Cap Ply LWC-98 Min. 22 ga., Type BV, Grade 33 steel, 5 ft span or structural concrete None Min. 200 psi, min 2- inch Elastizell. None Flintlastic APP Base T Trufast FM-90 Base Sheet Fasteners 7-inch o.c. at the 4-inch lap and 7- inch o.c. in two (2), equally spaced, staggered center rows (Optional) APP-TA APP-TA -45.0 COLD APPLIED SYSTEMS: LWC-99 Min. 22 ga., Type BV, Grade 33 steel, 5 ft span or structural concrete None Min. 350 psi, min 2- inch Range II Elastizell with Zell-Crete Fibers. None Flintlastic Base 20, Flintlastic Poly SMS Base Sheet Trufast FM-90 Base Sheet Fasteners 7-inch o.c. at the 4-inch lap and 7- inch o.c. in two (2), equally spaced, staggered center rows (Optional) BP-CA2 or SBS-CA2 SBS-CA2 -45.0 LWC-100 Min. 22 ga., Type BV, Grade 33 steel, 5 ft span None Min. 350 psi, min 2- inch Range II Elastizell with Zell-Crete Fibers. None Glasbase Base Sheet, Flintlastic Poly SMS Base Sheet Trufast FM-90 Base Sheet Fasteners 7-inch o.c. at the 4-inch lap and 7- inch o.c. in two (2), equally spaced, staggered center rows (Optional) BP-CA3 or SBS-CA3 SBS-CA3 -52.5 LWC-101 Structural concrete None Min. 350 psi, min 2- inch Range II Elastizell with Zell-Crete Fibers. None Glasbase Base Sheet, Flintlastic Poly SMS Base Sheet Trufast FM-90 Base Sheet Fasteners 7-inch o.c. at the 4-inch lap and 7- inch o.c. in two (2), equally spaced, staggered center rows (Optional) BP-CA3 or SBS-CA3 SBS-CA3 -60.0 MEARLCRETE (FL13492): CONVENTIONAL SYSTEMS: LWC-102 Min. 22 ga., Type BV, Grade 33 steel, 5 ft span or structural concrete None Min. 250 psi, min 2- inch Mearlcrete. None Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet, Flintlastic Poly SMS Base Sheet or Flintglas MS Cap (inverted) OMG CR Base Ply Fasteners (1.7) 7-inch o.c. at the 4-inch lap and 7- inch o.c. in two (2), equally spaced, staggered center rows (Optional) BP-AA or SBS-AA SBS-AA or APP- TA -45.0 LWC-103 Min. 22 ga., Type BV, Grade 33 steel, 5 ft span or structural concrete None Min. 250 psi, min 2- inch Mearlcrete. None Flintlastic Poly SMS Base Sheet OMG CR Base Ply Fasteners (1.7) 7-inch o.c. at the 4-inch lap and 7- inch o.c. in two (2), equally spaced, staggered center rows (Optional) BP-AA or SBS-AA SBS-AA or APP- TA -52.5 LWC-104 Min. 22 ga., Type BV, Grade 33 steel, 5 ft span or structural concrete None Min. 300 psi, min 2- inch Mearlcrete. None Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet, Flintlastic Poly SMS Base Sheet or Flintglas MS Cap (inverted) OMG CR Base Ply Fasteners (1.7) 7-inch o.c. at the 4-inch lap and 7- inch o.c. in two (2), equally spaced, staggered center rows (Optional) BP-AA or SBS-AA SBS-AA or APP- TA -52.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R29 for FL2533-R28 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 29: 04/14/2022 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 56 of 70 TABLE 4F: LIGHTWEIGHT CONCRETE DECKS – REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE E: MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Lightweight Concrete (Note 14) Base Sheet Roof Cover (Note 15) MDP (psf) Type Surfacing Base Fasteners Spacing Base Ply Cap Ply PRE-EXISTENT CELLULAR LWC: LWC-105 Min. 22 ga., Type BV, Grade 40 steel Min. 470 psi, Min. 2- inch, pre-existent cellular lightweight concrete For reroof (tear-off), repair LWC spalls with Celcore SBS (Sanded Bonding Surface) Flintlastic Ultra Poly SMS Base Sheet Trufast Versa Fasteners (min. 2.25”) & Plates, two (2) screws per plate at 180° from each other* 9-inch o.c. within the min. 5- inch wide, heat-welded side laps (Optional) SBS-TA or APP-TA APP-TA -75.0 Note: *Field withdrawal resistance testing (Note 11) shall yield minimum 322 lbf. Additional Versa-Fast Fasteners within each Versa-Fast Plate may be utilized to produce minimum withdrawal resistance. For recover installations, screws shall be of sufficient length for minimum 2.25” embedment into the existing LWC assembly. TABLE 4G: LIGHTWEIGHT CONCRETE DECKS – REROOF (TEAR-OFF) SYSTEM TYPE F: NON-INSULATED, BONDED ROOF COVER System No. Deck (Note 1) Lightweight Concrete (Note 14) Roof Cover (Note 15) MDP (psf) Type Surfacing Base Ply Cap Ply PRE-EXISTENT CELLULAR LWC: LWC-106 Min. 22 ga., Type BV, Grade 40 steel Min. 400 psi, Min. 2- inch, pre-existent cellular lightweight concrete Repair LWC spalls with Celcore SBS (Sanded Bonding Surface) Flintlastic Ultra Poly SMS Base Sheet applied in HB Fuller “Millennium Hurricane Force Membrane Adhesive HS”, ribbons max. 6-inch o.c. 3-inch wide side laps and 6-inch wide end laps are hot-air-welded, torch-welded or sealed with HB Fuller “Millennium Hurricane Force Lap and Flashing Adhesive” SBS-CA1 or SBS-CA4 -75.0 LWC-107 Min. 22 ga., Type BV, Grade 40 steel Min. 400 psi, Min. 2- inch, pre-existent cellular lightweight concrete Repair LWC spalls with Celcore SBS (Sanded Bonding Surface) Flintlastic Ultra Poly SMS Base Sheet applied in HB Fuller “Millennium Hurricane Force Membrane Adhesive HS”, ribbons max. 6-inch o.c. 3-inch wide side laps and 6-inch wide end laps are hot-air-welded, torch-welded or sealed with HB Fuller “Millennium Hurricane Force Lap and Flashing Adhesive” Flintlastic FR-P, Flintlastic FR-P CoolStar, Flintlastic Premium FR-P, Flintlastic Premium FR-P CoolStar, or Flintlastic GMS, applied in HB Fuller “Millennium Hurricane Force Membrane Adhesive HS”, continuous ribbons maximum 6- inch o.c. 3-inch wide side laps and 6-inch wide end laps are hot-air-welded, torch-welded or sealed with HB Fuller “Millennium Hurricane Force Lap and Flashing Adhesive” -97.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R29 for FL2533-R28 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 29: 04/14/2022 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 57 of 70 TABLE 5A: CEMENTITIOUS WOOD FIBER DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER System No. Deck (Notes 1&12) Base Insulation Layer Top Insulation Layer Primer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply SELF-ADHERING SYSTEMS: CWF-1. Tectum Min. 1.5-inch ACFoam II or H- Shield M-OSFA (Optional) Additional layer(s) of base insulation and/or min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board. M-OSFA FlintPrime QD SBS-SA (Optional) SBS- SA SBS-SA -60.0 CWF-2. Tectum Min. 1.5-inch ACFoam II or H- Shield M-OSFA, 6- inch o.c. (Optional) Additional layer(s) of base insulation and/or min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board. M-OSFA, 6- inch o.c. FlintPrime QD SBS-SA (Optional) SBS- SA SBS-SA -90.0 CWF-3. Existing Tectum (re- roof only) Min. 1.5-inch ACFoam II, ENRGY 3 or Multi-Max FA3 OB500 Min. 0.25-inch DensDeck OB500 FlintPrime QD SBS-SA (Optional) SBS- SA SBS-SA -45.0* CWF-4. Existing Tectum (re- roof only) Min. 1.5-inch ACFoam II, ENRGY 3 or Multi-Max FA3 OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 None SBS-SA (Optional) SBS- SA SBS-SA -45.0* CWF-5. Tectum Min. 1-inch ENRGY 3, H-Shield or H-Shield CG or min. 1.5-inch Multi-Max FA3 or Ultra-Max Polyset BM or Polyset CRA Min. 0.25-inch DensDeck Polyset BM or Polyset CRA FlintPrime QD SBS-SA (Optional) SBS- SA SBS-SA -52.5 CWF-6. Tectum Min. 1-inch ENRGY 3, H-Shield or H-Shield CG or min. 1.5-inch Multi-Max FA3 or Ultra-Max Polyset BM or Polyset CRA Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Polyset BM or Polyset CRA None SBS-SA (Optional) SBS- SA SBS-SA -52.5 HYBRID SYSTEMS: CWF-7. Tectum Min. 1.5-inch ACFoam II or H- Shield M-OSFA (Optional) Additional layer(s) of base insulation and/or min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board. M-OSFA None SBS-SA-H (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -60.0 CWF-8. Tectum Min. 1.5-inch ACFoam II or H- Shield M-OSFA, 6- inch o.c. (Optional) Additional layer(s) of base insulation and/or min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board. M-OSFA, 6- inch o.c. None SBS-SA-H (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -90.0 CONVENTIONAL SYSTEMS: CWF-9. Tectum Min. 1.5-inch ACFoam II or H- Shield M-OSFA Optional additional layers of base insulation, followed by min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board M-OSFA None BP-AA, SBS- AA, SBS-TA or APP-TA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -60.0 CWF-10. Tectum Min. 1.5-inch ACFoam II or H- Shield M-OSFA, 6- inch o.c. Optional additional layers of base insulation, followed by min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board. M-OSFA, 6- inch o.c. None BP-AA, SBS- AA, SBS-TA or APP-TA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -90.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R29 for FL2533-R28 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 29: 04/14/2022 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 58 of 70 TABLE 5A: CEMENTITIOUS WOOD FIBER DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER System No. Deck (Notes 1&12) Base Insulation Layer Top Insulation Layer Primer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply CWF-11. Existing Tectum (re- roof only) Min. 1.5-inch ACFoam II, ENRGY 3 or Multi-Max FA3 OB500 Min. 0.5-inch Structodek High Density Fiberboard OB500 None BP-AA or SBS-AA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -45.0* CWF-12. Existing Tectum (re- roof only) Min. 1.5-inch ACFoam II, ENRGY 3 or Multi-Max FA3 OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board or DensDeck or DensDeck Prime OB500 None BP-AA, SBS- AA, SBS-TA or APP-TA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -45.0* CWF-13. Tectum Min. 1-inch ENRGY 3, H-Shield, or H-Shield CG, min. 1.3-inch ACFoam III or min. 1.5-inch Multi-Max FA3 or Ultra-Max Polyset BM or Polyset CRA Min. 0.5-inch Structodek High Density Fiberboard Polyset CRA None BP-AA or SBS-AA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -52.5 CWF-14. Tectum Min. 1-inch ENRGY 3, H-Shield or H-Shield CG or min. 1.5-inch Multi-Max FA3 or Ultra-Max Polyset BM or Polyset CRA Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board or DensDeck or DensDeck Prime Polyset BM or Polyset CRA None BP-AA, SBS- AA, SBS-TA or APP-TA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -52.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R29 for FL2533-R28 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 29: 04/14/2022 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 59 of 70 TABLE 5B: CEMENTITIOUS WOOF FIBER DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 15) MDP (psf) Type Fasteners (Note 11) Attach Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply HYBRID SYSTEMS: CWF-15. Tectum Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet or Flintglas MS Cap (inverted) Trufast Twin Loc-Nail Assembled Fastener (Field W/D > 80 lbf) 6-inch o.c. at the 4- inch lap and 10-inch o.c. in two (2), equally spaced, staggered center rows Min. 1.5-inch ACFoam II, ENRGY 3 or Multi-Max FA3 hot asphalt (Optional) Min. 0.25- inch SECUROCK Gypsum-Fiber Roof Board hot asphalt SBS-SA-H (Optional) SBS-AA, SBS-TA or APP-TA SBS-AA or APP-TA -60.0 CWF-16. Tectum Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet or Flintglas MS Cap (inverted) Trufast Twin Loc-Nail Assembled Fastener (Field W/D > 69 lbf) 7-inch o.c. at the 4- inch lap and 7-inch o.c. in two (2), equally spaced, staggered center rows Min. 1.5-inch ACFoam II, ENRGY 3 or Multi-Max FA3 hot asphalt (Optional) Min. 0.25- inch SECUROCK Gypsum-Fiber Roof Board hot asphalt SBS-SA-H (Optional) SBS-AA, SBS-TA or APP-TA SBS-AA or APP-TA -60.0 CONVENTIONAL SYSTEMS: CWF-17. Existing Tectum Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet or Flintglas MS Cap (inverted) Trufast Twin Loc-Nail Assembled Fastener (Field W/D > 80 lbf) 6-inch o.c. at the 4- inch lap and 10-inch o.c. in two (2), equally spaced, staggered center rows Min. 1.5-inch ACFoam II, ENRGY 3 or Multi-Max FA3 hot asphalt Min. 0.75-inch FescoBoard (homogeneous) or min. 0.5-inch Structodek High Density Fiberboard hot asphalt BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-AA or APP-TA -60.0 CWF-18. Existing Tectum Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet or Flintglas MS Cap (inverted) Trufast Twin Loc-Nail Assembled Fastener (Field W/D > 69 lbf) 7-inch o.c. at the 4- inch lap and 7-inch o.c. in two (2), equally spaced, staggered center rows Min. 1.5-inch ACFoam II, ENRGY 3 or Multi-Max FA3 hot asphalt Min. 0.75-inch FescoBoard (homogeneous) or min. 0.5-inch Structodek High Density Fiberboard hot asphalt BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-AA or APP-TA -60.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R29 for FL2533-R28 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 29: 04/14/2022 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 60 of 70 TABLE 5C: CEMENTITIOUS WOOD FIBER DECKS – REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer(s) Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Fasteners (Note 11) Attach Base Ply Ply Cap Ply CWF-19. Existing Tectum (Optional) One or more layers, any combination, loose laid Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation OMG Polymer GypTec with 3” GypTec Plate (Field W/D > 180 lbf) 1 per 2.0 ft2 BP-AA or SBS-AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA or APP-TA -45.0* CWF-20. Existing Tectum (Optional) One or more layers, any combination, loose laid Min. 0.25-inch DensDeck or DensDeck Prime OMG Polymer GypTec with 3” GypTec Plate (Field W/D > 160 lbf) 1 per 1.8 ft2 BP-AA, SBS-AA, SBS- TA or APP-TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA or APP-TA -45.0* CWF-21. Existing Tectum (Optional) One or more layers, any combination, loose laid Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation Trufast Twin Loc-Nail Assembled Fasteners (Field W/D > 180 lbf) 1 per 2.0 ft2 BP-AA or SBS-AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA or APP-TA -45.0* CWF-22. Existing Tectum (Optional) One or more layers, any combination, loose laid Min. 0.25-inch DensDeck or DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Trufast Twin Loc-Nail Assembled Fasteners (Field W/D > 180 lbf) 1 per 2.0 ft2 BP-AA, SBS-AA, SBS- TA or APP-TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA or APP-TA -45.0* TABLE 5D: CEMENTITOUS WOOD FIBER DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) OR REROOF SYSTEM TYPE E-2: MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Base Sheet Roof Cover (Note 15) MDP (psf) Base Fasteners (Note 11) Attach Base Ply Cap Ply SELF-ADHERING SYSTEMS: CWF-23. Tectum Flintlastic SA NailBase Trufast Twin Loc-Nail Assembled Fastener (Field W/D > 80 lbf) 6-inch o.c. at the 4-inch lap and 10-inch o.c. in two (2), equally spaced, staggered center rows SBS-SA SBS-SA -60.0 CWF-24. Tectum Flintlastic SA NailBase Trufast Twin Loc-Nail Assembled Fastener (Field W/D > 69 lbf) 7-inch o.c. at the 4-inch lap and 7-inch o.c. in two (2), equally spaced, staggered center rows SBS-SA SBS-SA -60.0 CONVENTIONAL SYSTEMS: CWF-25. Existing Tectum (reroof only) All Weather/Empire Base Sheet or Flintglas MS Cap (inverted) Trufast Insuldeck Loc-Nail Base Sheet Fastener (Field W/D > 53 lbf) 9-inch o.c. at the 4-inch lap and 12-inch o.c. in two (2), equally spaced, staggered center rows BP-AA or SBS-AA SBS-AA -30.0* CWF-26. Existing Tectum (reroof only) All Weather/Empire Base Sheet or Flintglas MS Cap (inverted) Trufast Insuldeck Loc-Nail Base Sheet Fastener (Field W/D > 55 lbf) 7½-inch o.c. at the 4-inch lap and 7½-inch o.c. in two (2), equally spaced, staggered center rows BP-AA or SBS-AA SBS-AA -45.0* CWF-27. Tectum Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet or Flintglas MS Cap (inverted) Trufast Twin Loc-Nail Assembled Fastener (Field W/D > 80 lbf) 6-inch o.c. at the 4-inch lap and 10-inch o.c. in two (2), equally spaced, staggered center rows BP-AA or SBS-AA SBS-AA or APP- TA -60.0 CWF-28. Tectum Glasbase Base Sheet, Flintlastic Base 20 or All Weather/Empire Base Sheet or Flintglas MS Cap (inverted) Trufast Twin Loc-Nail Assembled Fastener (Field W/D > 77 lbf) 7-inch o.c. at the 4-inch lap and 7-inch o.c. in two (2), equally spaced, staggered center rows BP-AA or SBS-AA SBS-AA or APP- TA -67.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R29 for FL2533-R28 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 29: 04/14/2022 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 61 of 70 TABLE 6A: GYPSUM DECKS – REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER System No. Deck (Notes 1 & 12) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply SELF-ADHERING SYSTEMS: G-1. Existing sound gypsum or gypsum plank Min. 1.5-inch ACFoam II, ACFoam III, ENRGY 3, H-Shield or H-Shield CG M-OSFA Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board M-OSFA SBS-SA (Optional) SBS-SA SBS-SA -172.5 G-2. Existing sound gypsum or gypsum plank Min. 1.5-inch ACFoam II, ENRGY 3 or Multi-Max FA3 M-OSFA Min. 0.25-inch DensDeck primed with FlintPrime QD M-OSFA SBS-SA (Optional) SBS-SA SBS-SA -192.5 G-3. Existing sound gypsum or gypsum plank One or more layer(s), min. 1.5-inch ACFoam II, ACFoam III, H-Shield or H- Shield CG M-PG1 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board M-PG1 SBS-SA (Optional) SBS-SA SBS-SA -172.5 G-4. Existing sound gypsum or gypsum plank Min. 1.5-inch ACFoam II or ENRGY 3 OB500 Min. 0.25-inch DensDeck primed with FlintPrime QD OB500 SBS-SA (Optional) SBS-SA SBS-SA -135.0 G-5. Existing sound gypsum or gypsum plank One or more layer(s), min. 1.5-inch ACFoam II, ACFoam III, H-Shield or H- Shield CG OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 SBS-SA (Optional) SBS-SA SBS-SA -172.5 G-6. Existing sound gypsum or gypsum plank One or more layer(s), min. 1.5-inch ACFoam II, ACFoam III, H-Shield or H- Shield CG Polyset BM Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Polyset BM SBS-SA (Optional) SBS-SA SBS-SA -172.5 G-7. Existing sound gypsum or gypsum plank One or more layer(s), min. 1-inch H- Shield or ENRGY 3, min. 1.3-inch ACFoam III or min. 1.5-inch ACFoam II, Multi-Max FA3 or Ultra-Max Polyset CRA Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Polyset CRA SBS-SA (Optional) SBS-SA SBS-SA -172.5 G-8. Existing sound gypsum or gypsum plank min. 1-inch H-Shield or ENRGY 3, min. 1.3-inch ACFoam III or min. 1.5-inch ACFoam II, Multi-Max FA3 or Ultra- Max Polyset CRA Min. 0.25-inch DensDeck primed with FlintPrime QD Polyset CRA SBS-SA (Optional) SBS-SA SBS-SA -192.5 HYBRID SYSTEMS: G-9. Existing sound gypsum or gypsum plank One or more layer(s), min. 1.5-inch ACFoam II, ACFoam III, H-Shield or H- Shield CG M-OSFA, M- PG1, OB500, Polyset BM, Polyset CRA (Optional) Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board M-OSFA, M- PG1, OB500, Polyset BM, Polyset CRA SBS-SA-H (Optional) SBS-AA, SBS-TA or APP-TA SBS-AA or APP-TA -187.5 CONVENTIONAL SYSTEMS: G-10. Existing sound gypsum or gypsum plank Min. 1.5-inch ACFoam II, ENRGY 3 or H-Shield M-OSFA Min. 0.5-inch Structodek High Density Fiberboard M-OSFA BP-AA or SBS- AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA or APP-TA -127.5 G-11. Existing sound gypsum or gypsum plank One or more layer(s), min. 1.5-inch ACFoam II, ACFoam III, H-Shield or H- Shield CG M-OSFA Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board M-OSFA BP-AA or SBS- AA, SBS-TA or APP-TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA or APP-TA -187.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R29 for FL2533-R28 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 29: 04/14/2022 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 62 of 70 TABLE 6A: GYPSUM DECKS – REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER System No. Deck (Notes 1 & 12) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply G-12. Existing sound gypsum or gypsum plank Min. 1.5-inch ACFoam II, ENRGY 3 or H-Shield M-OSFA Min. 0.25-inch DensDeck M-OSFA BP-AA or SBS- AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA or APP-TA -232.5 G-13. Existing sound gypsum or gypsum plank Min. 2-inch ACFoam II, ENRGY 3 or H- Shield M-OSFA Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board M-OSFA BP-AA or SBS- AA, SBS-TA or APP-TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA or APP-TA -202.5 G-14. Existing sound gypsum or gypsum plank One or more layer(s), min. 1.5-inch ACFoam II, ACFoam III, H-Shield or H- Shield CG M-PG1 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board M-PG1 BP-AA or SBS- AA, SBS-TA or APP-TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA or APP-TA -187.5 G-15. Existing sound gypsum or gypsum plank Min. 1.5-inch ACFoam II, ENRGY 3 or H-Shield OB500 Min. 0.5-inch Structodek High Density Fiberboard OB500 BP-AA or SBS- AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA or APP-TA -120.0 G-16. Existing sound gypsum or gypsum plank Min. 1.5-inch ACFoam II, ENRGY 3 or H-Shield OB500 Min. 0.25-inch DensDeck, DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 BP-AA, SBS- AA, SBS-TA or APP-TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA or APP-TA -135.0 G-17. Existing sound gypsum or gypsum plank One or more layer(s), min. 1.5-inch ACFoam II, ACFoam III, H-Shield or H- Shield CG OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 BP-AA, SBS- AA, SBS-TA or APP-TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA or APP-TA -187.5 G-18. Existing sound gypsum or gypsum plank One or more layer(s), min. 1.5-inch ACFoam II, ACFoam III, H-Shield or H- Shield CG Polyset BM Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Polyset BM BP-AA, SBS- AA, SBS-TA or APP-TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA or APP-TA -187.5 G-19. Existing sound gypsum or gypsum plank Min. 1-inch ENRGY 3, H-Shield or H- Shield CG or min. 1.5-inch Multi-Max FA3 or Ultra-Max Polyset CRA Min. 0.5-inch Structodek High Density Fiberboard Polyset CRA BP-AA or SBS- AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA or APP-TA -180.0 G-20. Existing sound gypsum or gypsum plank One or more layer(s), min. 1.5-inch ACFoam II, ACFoam III, H-Shield or H- Shield CG Polyset CRA Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Polyset CRA BP-AA, SBS- AA, SBS-TA or APP-TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA or APP-TA -187.5 G-21. Existing sound gypsum or gypsum plank Min. 1-inch ENRGY 3, H-Shield or H- Shield CG or min. 1.5-inch Multi-Max FA3 or Ultra-Max Polyset CRA Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Polyset CRA BP-AA or SBS- AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA or APP-TA -225.0 G-22. Existing sound gypsum or gypsum plank Min. 1-inch ENRGY 3, H-Shield or H- Shield CG or min. 1.5-inch Multi-Max FA3 or Ultra-Max Polyset CRA Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Polyset CRA SBS-TA or APP-TA (Optional) SBS-TA or APP-TA APP-TA -232.5 G-23. Existing sound gypsum or gypsum plank Min. 1-inch ENRGY 3, H-Shield or H- Shield CG or min. 1.5-inch Multi-Max FA3 or Ultra-Max Polyset CRA Min. 0.25-inch DensDeck Polyset CRA BP-AA or SBS- AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA or APP-TA -240.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R29 for FL2533-R28 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 29: 04/14/2022 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 63 of 70 TABLE 6B: GYPSUM DECKS – REROOF (TEAR-OFF) SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 15) MDP (psf) Type Fasteners (Note 11) Attach Type Attach Type Attach Base Ply Ply Cap Ply HYBRID SYSTEMS: G-24. Existing sound gypsum or gypsum plank Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet or Flintglas MS Cap (inverted) Trufast Twin Loc- Nail Assembled Fastener (Field W/D > 80 lbf) 6-inch o.c. at the 4-inch lap and 10- inch o.c. in two (2), equally spaced, staggered center rows Min. 1.5-inch ACFoam II, ENRGY 3 or Multi-Max FA3 hot asphalt None N/A SBS-SA- H (Optional) SBS-AA, SBS-TA or APP-TA SBS-AA or APP-TA -60.0 G-25. Existing sound gypsum or gypsum plank Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet or Flintglas MS Cap (inverted) Trufast Twin Loc- Nail Assembled Fastener (Field W/D > 69 lbf) 7-inch o.c. at the 4-inch lap and 7- inch o.c. in two (2), equally spaced, staggered center rows Min. 1.5-inch ACFoam II, ENRGY 3 or Multi-Max FA3 hot asphalt None N/A SBS-SA- H (Optional) SBS-AA, SBS-TA or APP-TA SBS-AA or APP-TA -60.0 CONVENTIONAL SYSTEMS: G-26. Existing sound gypsum or gypsum plank All Weather/Empire Base Sheet or Flintglas MS Cap (inverted) Trufast FM-75 or FM-90 Base Sheet Fastener or Twin Loc-Nail Assembled Fastener (Field W/D > 100 lbf) 9-inch o.c. at the 4-inch lap and 18- inch o.c. in two (2), equally spaced, staggered center rows (Optional) Min. 1.5- inch ACFoam II, ENRGY 3 or Multi- Max FA3 hot asphalt Min. 0.75-inch FescoBoard (homogeneous) or min. 0.5-inch Structodek High Density Fiberboard hot asphalt BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-AA or APP-TA -45.0* G-27. Existing sound gypsum or gypsum plank Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet or Flintglas MS Cap (inverted) Trufast Twin Loc- Nail Assembled Fastener (Field W/D > 80 lbf) 6-inch o.c. at the 4-inch lap and 10- inch o.c. in two (2), equally spaced, staggered center rows Min. 1.5-inch ACFoam II, ENRGY 3 or Multi-Max FA3 hot asphalt Min. 0.75-inch FescoBoard (homogeneous) or min. 0.5-inch Structodek High Density Fiberboard hot asphalt BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-AA or APP-TA -60.0 G-28. Existing sound gypsum or gypsum plank Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet or Flintglas MS Cap (inverted) Trufast Twin Loc- Nail Assembled Fastener (Field W/D > 69 lbf) 7-inch o.c. at the 4-inch lap and 7- inch o.c. in two (2), equally spaced, staggered center rows Min. 1.5-inch ACFoam II, ENRGY 3 or Multi-Max FA3 hot asphalt Min. 0.75-inch FescoBoard (homogeneous) or min. 0.5-inch Structodek High Density Fiberboard hot asphalt BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-AA or APP-TA -60.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R29 for FL2533-R28 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 29: 04/14/2022 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 64 of 70 TABLE 6C: GYPSUM DECKS – REROOF (TEAR-OFF) SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer(s) Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Fasteners (Note 11) Attach Base Ply Ply Cap Ply G-29. Existing sound gypsum or gypsum plank (Optional) One or more layers, any combination, loose laid Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation OMG Polymer GypTec with 3” GypTec Plate (Field W/D > 180 lbf) 1 per 2.0 ft2 BP-AA or SBS- AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA or APP-TA -45.0* G-30. Existing sound gypsum or gypsum plank (Optional) One or more layers, any combination, loose laid Min. 0.25-inch DensDeck or DensDeck Prime OMG Polymer GypTec with 3” GypTec Plate (Field W/D > 160 lbf) 1 per 1.8 ft2 BP-AA, SBS- AA, SBS-TA or APP-TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA or APP-TA -45.0* G-31. Existing sound gypsum or gypsum plank (Optional) One or more layers, any combination, loose laid Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation Trufast Twin Loc-Nail Assembled Fasteners (Field W/D > 180 lbf) 1 per 2.0 ft2 BP-AA or SBS- AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA or APP-TA -45.0* G-32. Existing sound gypsum or gypsum plank (Optional) One or more layers, any combination, loose laid Min. 0.25-inch DensDeck or DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Trufast Twin Loc-Nail Assembled Fasteners (Field W/D > 180 lbf) 1 per 2.0 ft2 BP-AA, SBS- AA, SBS-TA or APP-TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA or APP-TA -45.0* TABLE 6D: GYPSUM DECKS – REROOF (TEAR-OFF) SYSTEM TYPE E-2: MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Base Sheet Roof Cover (Note 15) MDP (psf) Base Fasteners (Note 11) Attach Base Ply Cap Ply SELF-ADHERING SYSTEMS: G-33. Existing sound gypsum or gypsum plank Flintlastic SA NailBase Trufast Twin Loc-Nail Assembled Fastener (Field W/D > 80 lbf) 6-inch o.c. at the 4-inch lap and 10-inch o.c. in two (2), equally spaced, staggered center rows SBS-SA SBS-SA -60.0 G-34. Existing sound gypsum or gypsum plank Flintlastic SA NailBase Trufast Twin Loc-Nail Assembled Fastener (Field W/D > 88 lbf) 9-inch o.c. at the 4-inch lap and 9-inch o.c. in two (2), equally spaced, staggered center rows SBS-SA SBS-SA -60.0 CONVENTIONAL SYSTEMS: G-35. Existing sound gypsum or gypsum plank All Weather/Empire Base Sheet or Flintglas MS Cap (inverted) Trufast FM-75 or FM-90 Base Sheet Fastener or Twin Loc-Nail Assembled Fastener (Field W/D > 100 lbf) 9-inch o.c. at the 4-inch lap and 18-inch o.c. in two (2), equally spaced, staggered center rows BP-AA or SBS- AA SBS-AA -45.0* G-36. Existing sound gypsum or gypsum plank Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet or Flintglas MS Cap (inverted) Trufast Twin Loc-Nail Assembled Fastener (Field W/D > 80 lbf) 6-inch o.c. at the 4-inch lap and 10-inch o.c. in two (2), equally spaced, staggered center rows BP-AA or SBS- AA SBS-AA or APP-TA -60.0 G-37. Existing sound gypsum or gypsum plank Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet or Flintglas MS Cap (inverted) Trufast Twin Loc-Nail Assembled Fastener (Field W/D > 100 lbf) 9-inch o.c. at the 4-inch lap and 9-inch o.c. in two (2), equally spaced, staggered center rows BP-AA or SBS- AA SBS-AA or APP-TA -67.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R29 for FL2533-R28 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 29: 04/14/2022 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 65 of 70 TABLE 7A: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER A The reported MDP documents the allowable maximum design pressure of the new insulation and roof cover when installed atop the substrate, irrespective of the deck type (See Note 1) or performance of the substrate (See Note 12). The deck and substrate shall be capable of resisting the project design pressure requirements, not to exceed the noted MDP, to the satisfaction of the Authority Having Jurisdiction. System No. Substrate (Notes 1 & 12) Base Insulation Layer Top Insulation Layer Primer Roof Cover (Note 15) MDP (psf)A Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply SELF-ADHERING SYSTEMS: R-1 Existing fully bonded BUR or modified bitumen roof cover (Optional) Min. 1.5-inch ACFoam II, ENRGY 3, H- Shield or Multi-Max FA3 hot asphalt Min. 0.25-inch DensDeck hot asphalt FlintPrime QD SBS-SA (Optional) SBS-SA SBS-SA -105.0 R-2 Existing fully bonded BUR or modified bitumen roof cover (Optional) Min. 1.5-inch ACFoam II, ENRGY 3, H- Shield or Multi-Max FA3 hot asphalt Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board hot asphalt None SBS-SA (Optional) SBS-SA SBS-SA -105.0 R-3 Existing fully-bonded smooth- or granule- surface asphalt BUR or SBS modified bitumen or granule-surface APP modified bitumen (Optional) Min. 1.5-inch ACFoam II or H-Shield M-OSFA or M- PG1 Min. 0.5-inch ACFoam-HD Coverboard or H-Shield HD M-OSFA or M- PG1 FlintPrime QD SBS-SA (Optional) SBS-SA SBS-SA -97.5 R-4 Existing fully-bonded smooth- or granule- surface asphalt BUR or SBS modified bitumen or granule-surface APP modified bitumen (Optional) Min. 1.5-inch ACFoam II, ENRGY 3 or H- Shield M-OSFA or M- PG1 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board M-OSFA or M- PG1 None SBS-SA (Optional) SBS-SA SBS-SA -172.5 R-5 Existing fully-bonded smooth- or granule- surface asphalt BUR or SBS modified bitumen or granule-surface APP modified bitumen (Optional) Min. 1.5-inch ACFoam II, ENRGY 3 or Multi-Max FA3 M-OSFA or M- PG1 Min. 0.25-inch DensDeck M-OSFA or M- PG1 FlintPrime QD SBS-SA (Optional) SBS-SA SBS-SA -192.5 R-6 Existing fully-bonded smooth- or granule- surface asphalt BUR or SBS modified bitumen or granule-surface APP modified bitumen (Optional) Min. 1.5-inch ACFoam II or H-Shield M-OSFA or M- PG1, 6-inch o.c. Min. 0.5-inch ACFoam-HD Coverboard or H-Shield HD M-OSFA or M- PG1, 6-inch o.c. FlintPrime QD SBS-SA (Optional) SBS-SA SBS-SA -315.0 R-7 Existing fully-bonded smooth- or granule- surface asphalt BUR or SBS modified bitumen or granule-surface APP modified bitumen (Optional) Min. 1.5-inch ACFoam II or H-Shield M-OSFA or M- PG1, 6-inch o.c. Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board M-OSFA or M- PG1, 6-inch o.c. FlintPrime QD SBS-SA (Optional) SBS-SA SBS-SA -315.0 R-8 Existing fully bonded BUR or modified bitumen roof cover (Optional) Min. 1.5-inch ACFoam II or ENRGY 3 OB500 Min. 0.25-inch DensDeck OB500 FlintPrime QD SBS-SA (Optional) SBS-SA SBS-SA -120.0 R-9 Existing fully bonded BUR or modified bitumen roof cover (Optional) Min. 1.5-inch ACFoam II or ENRGY 3 OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 None SBS-SA (Optional) SBS-SA SBS-SA -120.0 R-10 Existing fully-bonded smooth- or granule- surface asphalt BUR or granule-surface modified bitumen (Optional) Min. 1.5-inch ACFoam II or H-Shield Polyset BM Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Polyset BM None SBS-SA (Optional) SBS-SA SBS-SA -172.5 R-11 Existing fully-bonded smooth- or granule- surface asphalt BUR or granule-surface modified bitumen (Optional) Min. 1.5-inch ACFoam II or H-Shield Polyset BM Min. 0.25-inch DensDeck Polyset BM FlintPrime QD SBS-SA (Optional) SBS-SA SBS-SA -192.5 R-12 Existing fully-bonded smooth- or granule- surface asphalt BUR or SBS modified bitumen or granule-surface APP modified bitumen (Optional) Min. 1.5-inch ACFoam II or H-Shield Polyset CRA Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Polyset CRA None SBS-SA (Optional) SBS-SA SBS-SA -172.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R29 for FL2533-R28 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 29: 04/14/2022 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 66 of 70 TABLE 7A: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER A The reported MDP documents the allowable maximum design pressure of the new insulation and roof cover when installed atop the substrate, irrespective of the deck type (See Note 1) or performance of the substrate (See Note 12). The deck and substrate shall be capable of resisting the project design pressure requirements, not to exceed the noted MDP, to the satisfaction of the Authority Having Jurisdiction. System No. Substrate (Notes 1 & 12) Base Insulation Layer Top Insulation Layer Primer Roof Cover (Note 15) MDP (psf)A Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply R-13 Existing fully-bonded smooth- or granule- surface asphalt BUR or SBS modified bitumen or granule-surface APP modified bitumen (Optional) Min. 1.5-inch ACFoam II or H-Shield Polyset CRA Min. 0.25-inch DensDeck Polyset CRA FlintPrime QD SBS-SA (Optional) SBS-SA SBS-SA -192.5 HYBRID SYSTEMS: R-14 Existing fully bonded BUR or modified bitumen roof cover (Optional) Min. 1.5-inch ACFoam II, ENRGY 3, H- Shield or Multi-Max FA3 hot asphalt Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board hot asphalt None SBS-SA-H (Optional) SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -105.0 R-15 Existing fully-bonded smooth- or granule- surface asphalt BUR or SBS modified bitumen or granule-surface APP modified bitumen (Optional) Min. 1.5-inch ACFoam II or H-Shield M-OSFA or M- PG1 Min. 0.5-inch ACFoam-HD CoverBoard or H-Shield HD M-OSFA or M- PG1 None SBS-SA-H (Optional) SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -97.5 R-16 Existing fully-bonded smooth- or granule- surface asphalt BUR or SBS modified bitumen or granule-surface APP modified bitumen (Optional) Min. 1.5-inch ACFoam II or H-Shield M-OSFA or M- PG1 (Optional) Additional layer(s) base insulation M-OSFA or M- PG1 None SBS-SA-H (Optional) SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -210.0 R-17 Existing fully-bonded smooth- or granule- surface asphalt BUR or SBS modified bitumen or granule-surface APP modified bitumen (Optional) Min. 1.5-inch ACFoam II or H-Shield M-OSFA or M- PG1 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board M-OSFA or M- PG1 None SBS-SA-H (Optional) SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -210.0 R-18 Existing fully-bonded smooth- or granule- surface asphalt BUR or SBS modified bitumen or granule-surface APP modified bitumen (Optional) Min. 1.5-inch ACFoam II or H-Shield M-OSFA or M- PG1, 6-inch o.c. Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board or min. 0.5-inch ACFoam-HD CoverBoard or H-Shield HD M-OSFA or M- PG1, 6-inch o.c. None SBS-SA-H (Optional) SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -315.0 R-19 Existing fully bonded, smooth- or granule- surface BUR or modified bitumen (Optional) Min. 1.5-inch ACFoam II or ENRGY 3 OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 None SBS-SA-H (Optional) SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -120.0 R-20 Existing fully-bonded smooth- or granule- surface asphalt BUR or granule-surface modified bitumen (Optional) Min. 1.5-inch ACFoam II or H-Shield Polyset BM (Optional) Additional layer(s) base insulation Polyset BM None SBS-SA-H (Optional) SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -195.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R29 for FL2533-R28 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 29: 04/14/2022 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 67 of 70 TABLE 7A: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER A The reported MDP documents the allowable maximum design pressure of the new insulation and roof cover when installed atop the substrate, irrespective of the deck type (See Note 1) or performance of the substrate (See Note 12). The deck and substrate shall be capable of resisting the project design pressure requirements, not to exceed the noted MDP, to the satisfaction of the Authority Having Jurisdiction. System No. Substrate (Notes 1 & 12) Base Insulation Layer Top Insulation Layer Primer Roof Cover (Note 15) MDP (psf)A Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply R-21 Existing fully-bonded smooth- or granule- surface asphalt BUR or granule-surface modified bitumen (Optional0 Min. 1.5-inch ACFoam II or H-Shield Polyset BM Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Polyset BM None SBS-SA-H (Optional) SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -195.0 R-22 Existing fully-bonded smooth- or granule- surface asphalt BUR or SBS modified bitumen or granule-surface APP modified bitumen Min. 1.5-inch ACFoam II or H-Shield Polyset CRA (Optional) Additional layer(s) base insulation Polyset CRA None SBS-SA-H (Optional) SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -222.5 R-23 Existing fully-bonded smooth- or granule- surface asphalt BUR or SBS modified bitumen or granule-surface APP modified bitumen (Optional) Min. 1.5-inch ACFoam II or H-Shield Polyset CRA Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Polyset CRA None SBS-SA-H (Optional) SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -217.5 CONVENTIONAL SYSTEMS: R-24 Existing fully bonded BUR or modified bitumen roof cover (Optional) Min. 1.5-inch ACFoam II, ENRGY 3, H- Shield or Multi-Max FA3 hot asphalt Min. 0.5-inch Structodek High Density Fiberboard, Min. 0.75-inch FescoBoard (homogeneous) or Min. 0.5- inch DuraBoard (homogeneous) hot asphalt None BP-AA or SBS-AA (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP-TA -105.0 R-25 Existing fully bonded BUR or modified bitumen roof cover (Optional) Min. 1.5-inch ACFoam II, ENRGY 3, H- Shield or Multi-Max FA3 hot asphalt 0.25-inch DensDeck, DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board hot asphalt None BP-AA, SBS-AA, SBS-TA or APP-TA (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP-TA -105.0 R-26 Existing fully-bonded smooth- or granule- surface asphalt BUR or SBS modified bitumen or granule-surface APP modified bitumen (Optional) Min. 1.5-inch ACFoam II, ENRGY 3 or H- Shield M-OSFA or M- PG1 Min. 0.5-inch Structodek High Density Fiberboard M-OSFA or M- PG1 None BP-AA or SBS-AA (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP-TA -165.0 R-27 Existing fully-bonded smooth- or granule- surface asphalt BUR or SBS modified bitumen or granule-surface APP modified bitumen (Optional) Min. 1.5-inch ACFoam II, ENRGY 3 or H- Shield M-OSFA or M- PG1 Min. 0.25-inch DensDeck M-OSFA or M- PG1 None BP-AA or SBS-AA (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP-TA -210.0 R-28 Existing fully-bonded smooth- or granule- surface asphalt BUR or SBS modified bitumen or granule-surface APP modified bitumen (Optional) Min. 1.5-inch ACFoam II or H-Shield M-OSFA or M- PG1 Min. 0.25-inch DensDeck Prime M-OSFA or M- PG1 None BP-AA, SBS-AA, SBS-TA (Optional) BP-AA, SBS- AA or SBS- TA SBS-AA -210.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R29 for FL2533-R28 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 29: 04/14/2022 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 68 of 70 TABLE 7A: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER A The reported MDP documents the allowable maximum design pressure of the new insulation and roof cover when installed atop the substrate, irrespective of the deck type (See Note 1) or performance of the substrate (See Note 12). The deck and substrate shall be capable of resisting the project design pressure requirements, not to exceed the noted MDP, to the satisfaction of the Authority Having Jurisdiction. System No. Substrate (Notes 1 & 12) Base Insulation Layer Top Insulation Layer Primer Roof Cover (Note 15) MDP (psf)A Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply R-29 Existing fully-bonded smooth- or granule- surface asphalt BUR or SBS modified bitumen or granule-surface APP modified bitumen (Optional) Min. 2-inch ACFoam II, ENRGY 3 or H- Shield M-OSFA or M- PG1 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board M-OSFA or M- PG1 None BP-AA, SBS-AA, SBS-TA or APP-TA (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP-TA -210.0 R-30 Existing fully-bonded smooth- or granule- surface asphalt BUR or SBS modified bitumen or granule-surface APP modified bitumen (Optional) Min. 1.5-inch ACFoam II or H-Shield M-OSFA or M- PG1, 6-inch o.c. Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board M-OSFA or M- PG1, 6-inch o.c. None SBS-AA or SBS-TA (Optional) SBS-AA or SBS-TA SBS-AA -315.0 R-31 Existing fully-bonded smooth- or granule- surface asphalt BUR or SBS modified bitumen or granule-surface APP modified bitumen (Optional) Min. 1.5-inch ACFoam II or H-Shield M-OSFA or M- PG1, 6-inch o.c. Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board M-OSFA or M- PG1, 6-inch o.c. None Flintlastic STA or Flintlastic STA Plus (Optional) APP-TA APP-TA -315.0 R-32 Existing fully bonded BUR or modified bitumen roof cover (Optional) Min. 1.5-inch ACFoam II, ENRGY 3 or H- Shield OB500 Min. 0.5-inch Structodek High Density Fiberboard OB500 None BP-AA or SBS-AA (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP-TA -120.0 R-33 Existing fully bonded BUR or modified bitumen roof cover (Optional) Min. 1.5-inch ACFoam II, ENRGY 3 or H- Shield OB500 Min. 0.25-inch DensDeck, DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 None BP-AA, SBS-AA, SBS-TA or APP-TA (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP-TA -120.0 R-34 Existing fully-bonded smooth- or granule- surface asphalt BUR or granule-surface modified bitumen (Optional) Min. 1.5-inch ACFoam II or H-Shield Polyset BM Min. 0.25-inch DensDeck Polyset BM None BP-AA or SBS-AA (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP-TA -195.0 R-35 Existing fully-bonded smooth- or granule- surface asphalt BUR or granule-surface modified bitumen (Optional) Min. 1.5-inch ACFoam II or H-Shield Polyset BM Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Polyset BM None BP-AA, SBS-AA, SBS-TA or APP-TA (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP-TA -195.0 R-36 Existing fully-bonded smooth- or granule- surface asphalt BUR or SBS modified bitumen or granule-surface APP modified bitumen Min. 1.5-inch ACFoam II or H-Shield Polyset CRA Min. 0.5-inch Structodek High Density Fiberboard Polyset CRA None BP-AA or SBS-AA (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP-TA -180.0 R-37 Existing fully-bonded smooth- or granule- surface asphalt BUR or SBS modified bitumen or granule-surface APP modified bitumen (Optional) Min. 1.5-inch ACFoam II or H-Shield Polyset CRA Min. 0.25-inch DensDeck Polyset CRA None BP-AA or SBS-AA (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP-TA -222.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R29 for FL2533-R28 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 29: 04/14/2022 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 69 of 70 TABLE 7A: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER A The reported MDP documents the allowable maximum design pressure of the new insulation and roof cover when installed atop the substrate, irrespective of the deck type (See Note 1) or performance of the substrate (See Note 12). The deck and substrate shall be capable of resisting the project design pressure requirements, not to exceed the noted MDP, to the satisfaction of the Authority Having Jurisdiction. System No. Substrate (Notes 1 & 12) Base Insulation Layer Top Insulation Layer Primer Roof Cover (Note 15) MDP (psf)A Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply R-38 Existing fully-bonded smooth- or granule- surface asphalt BUR or SBS modified bitumen or granule-surface APP modified bitumen (Optional) Min. 1.5-inch ACFoam II or H-Shield Polyset CRA Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Polyset CRA None BP-AA, SBS-AA, SBS-TA or APP-TA (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP-TA -222.5 COLD-APPLIED SYSTEMS: R-39 Existing fully-bonded smooth- or granule- surface asphalt BUR or SBS modified bitumen or granule-surface APP modified bitumen (Optional) Min. 1.5-inch ACFoam II or H-Shield M-OSFA or M- PG1 Min. 0.5-inch ACFoam-HD CoverBoard or H-Shield HD M-OSFA or M- PG1 None SBS-CA1 None SBS-CA1 -97.5 R-40 Existing fully-bonded smooth- or granule- surface asphalt BUR or SBS modified bitumen or granule-surface APP modified bitumen (Optional) Min. 1.5-inch ACFoam II or H-Shield M-OSFA or M- PG1 Min. 0.5-inch ACFoam-HD CoverBoard or H-Shield HD M-OSFA or M- PG1 None SBS-CA4 None SBS-CA4 -97.5 R-41 Existing fully-bonded smooth- or granule- surface asphalt BUR or SBS modified bitumen or granule-surface APP modified bitumen (Optional) Min. 0.5-inch ACFoam II or H-Shield M-OSFA or M- PG1 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board M-OSFA or M- PG1 None SBS-CA1 None SBS-CA1 -105.0 R-42 Existing fully-bonded smooth- or granule- surface asphalt BUR or SBS modified bitumen or granule-surface APP modified bitumen (Optional) Min. 0.5-inch ACFoam II or H-Shield M-OSFA or M- PG1 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board M-OSFA or M- PG1 None SBS-CA4 None SBS-CA4 -105.0 R-43 Existing fully bonded BUR or modified bitumen roof cover (Optional) Min. 0.5-inch ACFoam II or H-Shield OB500 Min. 1.5-inch ACFoam III or H-Shield CG OB500 None SBS-CA1 None SBS-CA1 -82.5 R-44 Existing fully bonded, smooth- or granule- surface BUR or modified bitumen (Optional) Min. 0.5-inch ACFoam II or H-Shield OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 None SBS-CA1 None SBS-CA1 -105.0 R-45 Existing fully bonded, smooth- or granule- surface BUR or modified bitumen (Optional) Min. 0.5-inch ACFoam II or H-Shield OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 None SBS-CA4 None SBS-CA4 -105.0 R-46 Existing fully-bonded smooth- or granule- surface asphalt BUR or granule-surface modified bitumen (Optional) Min. 0.5-inch ACFoam II or H-Shield Polyset BM Min. 1.5-inch ACFoam III Polyset BM None SBS-CA1 None SBS-CA1 -82.5 R-47 Existing fully-bonded smooth- or granule- surface asphalt BUR or granule-surface modified bitumen (Optional) Min. 0.5-inch ACFoam II or H-Shield Polyset BM Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Polyset BM None SBS-CA1 None SBS-CA1 -105.0 R-48 Existing fully-bonded smooth- or granule- surface asphalt BUR or granule-surface modified bitumen (Optional) Min. 0.5-inch ACFoam II or H-Shield Polyset BM Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Polyset BM None SBS-CA4 None SBS-CA4 -105.0 R-49 Existing fully-bonded smooth- or granule- surface asphalt BUR or SBS modified bitumen or granule-surface APP modified bitumen (Optional) Min. 0.5-inch ACFoam II or H-Shield Polyset CRA Min. 1.5-inch ACFoam III or H-Shield CG Polyset CRA None SBS-CA1 None SBS-CA1 -82.5 R-50 Existing fully-bonded smooth- or granule- surface asphalt BUR or SBS modified bitumen or granule-surface APP modified bitumen (Optional) Min. 0.5-inch ACFoam II or H-Shield Polyset CRA Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Polyset CRA None SBS-CA1 None SBS-CA1 -105.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R29 for FL2533-R28 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 29: 04/14/2022 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 70 of 70 TABLE 7A: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER A The reported MDP documents the allowable maximum design pressure of the new insulation and roof cover when installed atop the substrate, irrespective of the deck type (See Note 1) or performance of the substrate (See Note 12). The deck and substrate shall be capable of resisting the project design pressure requirements, not to exceed the noted MDP, to the satisfaction of the Authority Having Jurisdiction. System No. Substrate (Notes 1 & 12) Base Insulation Layer Top Insulation Layer Primer Roof Cover (Note 15) MDP (psf)A Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply R-51 Existing fully-bonded smooth- or granule- surface asphalt BUR or SBS modified bitumen or granule-surface APP modified bitumen (Optional) Min. 0.5-inch ACFoam II or H-Shield Polyset CRA Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Polyset CRA None SBS-CA4 None SBS-CA4 -105.0 TABLE 7B: RECOVER APPLICATIONS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE F: NON-INSULATED, BONDED ROOF COVER A The reported MDP documents the allowable maximum design pressure of the new roof cover when installed atop the substrate, irrespective of the deck type (See Note 1) or performance of the substrate (See Note 12). The deck and substrate shall be capable of resisting the project design pressure requirements, not to exceed the noted MDP, to the satisfaction of the Authority Having Jurisdiction. System No. Substrate (Notes 1 & 12) Primer Roof Cover (Note 15) MDP (psf)A Base Ply Ply Cap Ply R-52 Existing fully bonded asphalt built-up roof (BUR) (Optional) FlintPrime QD SBS-CA1 None SBS-CA1 -187.5 Revision Request/Correction to Comments **ALL INFORMATION HIGHLIGHTED IN GRAY IS REQUIRED. City of Atlantic Beach Building Department 800 Seminole Rd, Atlantic Beach, FL 32233 Phone: (904) 247-5826 Email: Building-Dept@coab.us PERMIT #: _____________________ Revision to Issued Permit OR Corrections to Comments Date: ________________ Project Address: ____________________________________________________________________________________ Contractor/Contact Name: ____________________________________________________________________________ Contact Phone: ______________________________ Email: _________________________________________________ Description of Proposed Revision / Corrections: __________________________________________________________________________________________________ __________________________________________________________________________________________________ __________________________________________________________________________________________________ __________________________________________________________________________________________________ I_______________________________ affirm the revision/correction to comments is inclusive of the proposed changes. (printed name)  Will proposed revision/corrections add additional square footage to original submittal? No Yes (additional s.f. to be added: _____________________________)  Will proposed revision/corrections add additional increase in building value to original submittal? No *Yes (additional increase in building value: $____________________) (Contractor must sign if increase in valuation) *Signature of Contractor/Agent: _______________________________________________________ __________________________________________________________________________________________________ (Office Use Only) Approved Denied Not Applicable to Department Permit Fee Due $_______________ Revision/Plan Review Comments_______________________________________________________________________ __________________________________________________________________________________________________ Department Review Required: Building _____________________________________________ Planning & Zoning Reviewed By Tree Administrator Public Works Public Utilities _____________________________________________ Public Safety Date Fire Services Updated 10/17/18 ROOF22-0041 07/21/2022 132 Seminole Road Jordan Roofing LLC/ Josua Jordan (904) 497-3167 jordanroofingllc@gmail.com Manufacturer's installation instructions and evaluation report are included. Jordan Roofing LLC/ Josua Jordan 4 4 4 By Mike Jones at 4:07 pm, Jul 28, 2022 50.00x NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R29 for FL2533-R28 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 29: 04/14/2022 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 1 of 70 APPENDIX 1: ATTACHMENT REQUIREMENTS FOR WIND UPLIFT RESISTANCE TABLE DECK APPLICATION TYPE DESCRIPTION PAGE 1A Wood New or Reroof (Tear-Off) A-1 Bonded Insulation, Bonded Roof Cover 6 1B Wood New or Reroof (Tear-Off) A-2 Mechanically Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 7-8 1C Wood New, Reroof (Tear-Off) or Recover B-1 Mechanically Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 9 1D Wood New, Reroof (Tear-Off) or Recover C-1 Mechanically Attached Insulation, Bonded Roof Cover 9-11 1E Wood New, Reroof (Tear-Off) or Recover D-2 Insulated, Mechanically Attached Base Sheet, Bonded Roof Cover 11-13 1F Wood New, Reroof (Tear-Off) E-2 Non-Insulated, Mechanically Attached Base Sheet, Bonded Roof Cover 13-16 1G Wood New, Reroof (Tear-Off) or Recover E-2 Non-Insulated, Mechanically Attached Base Sheet, Bonded Roof Cover 16-18 1H Wood New or Reroof (Tear-Off) F Non-Insulated, Bonded Roof Cover 18 2A Steel or Structural concrete New, Reroof (Tear-Off) or Recover B-1 Mechanically Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 19-21 2B Steel or Structural concrete New, Reroof (Tear-Off) or Recover C-1 Mechanically Attached Insulation, Bonded Roof Cover 22-25 2C Steel or Structural concrete New, Reroof (Tear-Off) or Recover D-2 Insulated, Mechanically Attached Base Sheet, Bonded Roof Cover 26-28 3A Structural concrete New or Reroof (Tear-Off) A-1 Bonded Insulation, Bonded Roof Cover 29-37 3B Structural concrete New or Reroof (Tear-Off) A-3 Bonded Temp Roof/Vapor Barrier, Bonded Insulation, Bonded Roof Cover 37 3C Structural concrete New or Reroof (Tear-Off) F Non-Insulated, Bonded Roof Cover 38 4A LWIC / steel New or Reroof (Tear-Off) A-1 Bonded Insulation, Bonded Roof Cover 39-40 4B LWIC / structural concrete New or Reroof (Tear-Off) A-1 Bonded Insulation, Bonded Roof Cover 41-45 4C LWIC / structural concrete New, Reroof (Tear-Off) A-1 Bonded Vapor Barrier, Bonded Insulation, Bonded Roof Cover 46-47 4D LWIC / steel New or Reroof (Tear-Off) A-2 Mechanically Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 48-50 4E LWIC / steel or struct. conc. New or Reroof (Tear-Off) E-2 Non-Insulated, Mechanically Attached Base Sheet, Bonded Roof Cover 51-55 4F LWIC / steel Reroof (Tear-Off) or Recover E-2 Non-Insulated, Mechanically Attached Base Sheet, Bonded Roof Cover 56 4G LWIC / steel Reroof (Tear-Off) F Non-Insulated, Bonded Roof Cover 56 5A Cementitious wood fiber New or Reroof (Tear-Off) A-1 Bonded Insulation, Bonded Roof Cover 57-58 5B Cementitious wood fiber New or Reroof (Tear-Off) or Recover A-2 Mechanically Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 59 5C Cementitious wood fiber Reroof (Tear-Off) or Recover C-1 Mechanically Attached Insulation, Bonded Roof Cover 60 5D Cementitious wood fiber New, Reroof (Tear-Off) or Recover E-2 Non-Insulated, Mechanically Attached Base Sheet, Bonded Roof Cover 60 6A Existing gypsum Reroof (Tear-Off) A-1 Bonded Insulation, Bonded Roof Cover 61-62 6B Existing gypsum Reroof (Tear-Off) A-2 Mechanically Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 63 6C Existing gypsum Reroof (Tear-Off) C-1 Mechanically Attached Insulation, Bonded Roof Cover 64 6D Existing gypsum Reroof (Tear-Off) E-2 Non-Insulated, Mechanically Attached Base Sheet, Bonded Roof Cover 64 7A Various Recover A-1 Bonded Insulation, Bonded Roof Cover 65-70 7B Various Recover F Non-Insulated, Bonded Roof Cover 70 By Mike Jones at 4:08 pm, Jul 28, 2022 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R29 for FL2533-R28 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 29: 04/14/2022 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 2 of 70 The following notes apply to the systems outlined herein: 1 The roof system evaluation herein pertains to above-deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. 2 Unless otherwise noted, fasteners and stress plates shall be as follows. Fasteners shall be of sufficient length for the following engagements: FASTENER/PLATE OPTIONS DECK TYPE BY FBC FILE PARTS MINIMUM ENGAGEMENT Wood Altenloh, Brinck and Co. U.S., Inc. FL4500 Trufast #14 HD with Trufast 3” Metal Insulation Plates Minimum ¾-inch plywood penetration or minimum 1-inch wood plank embedment OMG, Inc. FL699 OMG #14 Roofgrip with AccuTrac Plates or OMG #14 Heavy Duty with OMG 3 in. Galvalume Steel Plate SFS Group USA, Inc. FL20311 Dekfast DF-#14-PH3 with Dekfast PLT-H-2-7/8 or Dekfast PLT-R-3. Steel Altenloh, Brinck and Co. U.S., Inc. FL4500 Trufast #12 DP or Trufast #14 HD with Trufast 3” Metal Insulation Plates Minimum ¾-inch steel penetration and engage the top flute of the steel deck OMG, Inc. FL699 OMG #12 or #14 Roofgrip with AccuTrac Plates or OMG #12 Standard or OMG #14 Heavy Duty with OMG 3 in. Galvalume Steel Plate SFS Group USA, Inc. FL20311 Dekfast DF-#12-PH3 or DF-#14-PH3 with Dekfast PLT-H-2-7/8 or Dekfast PLT-R-3. Structural Concrete Altenloh, Brinck and Co. U.S., Inc. FL4500 Trufast #14 HD or Trufast Fluted Concrete Nail with Trufast 3” Metal Insulation Plates Minimum 1-inch embedment. Fasteners installed with a pilot hole in accordance with the fastener manufacturer’s published installation instructions OMG, Inc. FL699 OMG #14 Roofgrip with AccuTrac Plates or OMG #14 Heavy Duty or CD-10 with OMG 3 in. Galvalume Steel Plate SFS Group USA, Inc. FL20311 Dekfast DF-#14-PH3 with Dekfast PLT-H-2-7/8 or Dekfast PLT-R-3. 3 Unless otherwise noted, insulation may be any one layer or combination of FBC Approved (Local or Statewide) board(s) that meet FBC 1505 and, for foam plastic, FBC Chapter 26, when installed with the roof cover. 4 Minimum 200 psi, minimum 2-inch FBC Approved lightweight insulating concrete may be substituted for, or installed below, rigid insulation board for System Types B-1, C-1, C-2, D-1 or D-2, whereby fasteners are installed through the lightweight insulating concrete to engage the structural deck. The structural deck shall be of equal or greater type, thickness and strength to the steel and structural concrete deck listings. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. This is a wind uplift resistance allowance and does not purport to address non-wind-uplift-related issues, such as deck venting or moisture levels within the Lightweight Concrete and the potential effect on overlying components. 5 Preliminary insulation attachment for System Type D: Unless otherwise noted, refer to Section 2.2.10.1.3 of FM Loss Prevention Data Sheet 1-29 (February 2020). 6 Unless otherwise noted, insulation adhesive application rates are as follows. Ribbon or bead width is at the time of application; the ribbons/beads shall expand as noted in the manufacturer’s published instructions. When multiple layers(s) of insulation and/or coverboard are installed in ribbon-applied adhesive, board joints shall be staggered. The maximum edge distance from the adhesive ribbon to the edge of the insulation board shall be not less than one-half the specified ribbons spacing. INSULATION ADHESIVE REFERENCES BY FBC FILE ADHESIVE REFERENCE MINIMUM RATE NOTE DuPont de Nemours, Inc. FL720 Insta Stik Quik Set Insta Stick Continuous 0.75 to 1 inch wide ribbons, 12-inch o.c H.B. Fuller Company FL1800 Millennium One Step Foamable Adhesive M-OSFA Continuous 0.25 to 0.5-inch wide ribbons, 12-inch o.c. H.B. Fuller Company FL1800 Millennium PG-1 Pump Grade Adhesive M-PG1 Continuous 0.5 to 0.75-inch wide ribbons, 12-inch o.c. ICP Construction, Inc. FL22256 Polyset Board-Max Polyset BM Continuous 3-inch wide ribbons, 12-inch o.c. ICP Construction, Inc. FL1365 Polyset Commercial Roofing Adhesive Polyset CRA Continuous 2.5 to 3-inch wide ribbons, 12-inch o.c. Formerly Polyset CR-20 OMG, Inc. FL1608 OlyBond 500 Adhesive Fastener OB500 Continuous 0.75-inch wide ribbons, 12-inch o.c. PaceCart, SpotShot or Canister dispensing Generic, ASTM D312, Type IV N/A hot asphalt N/A Full coverage at 25-30 lbs/square If applying hot asphalt to concrete deck, deck shall be primed with ASTM D41 primer NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R29 for FL2533-R28 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 29: 04/14/2022 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 3 of 70 7 Unless otherwise noted, all insulations are flat-stock or taper board of the minimum thickness noted. Tapered polyisocyanurate at the following thickness limitations may be substituted with the following Maximum Design Pressure (MDP) limitations. In no case shall these values be used to ‘increase’ the MDP listings in the tables; rather if MDP listing below meets or exceeds that listed for a particular system in the tables, then the thinner board listed below may be used as a drop-in for the equivalent thicker material listed in the table. MDP LIMITATIONS FOR TAPERED POLYISOCYANURATE INSULATIONS ADHESIVE INSULATION MIN. TAPERED THICKNESS (IN) MDP (PSF) LISTED PRODUCT FBC FILE Insta Stik Any polyisocyanurate listed with adhesive herein Various 1.0 -120.0 M-OSFA Any polyisocyanurate listed with adhesive herein Various 1.0 -157.5 M-PG1 Any polyisocyanurate listed with adhesive herein Various 1.0 -157.5 Polyset CRA Any polyisocyanurate listed with adhesive herein Various 1.0 -117.5 OB500 Rmax Multi-Max FA3 FL11207 0.5 -45.0 OB500 Hunter H-Shield FL5968 0.5 -315.0 OB500 Johns Manville ENRGY 3 FL4205 0.5 -315.0 OB500 Atlas Roofing ACFoam II FL17989 0.5 -487.5 8 For adhered roof insulation and board-size: Unless otherwise noted, refer to Section 2.2.10.6.2 of FM Loss Prevention Data Sheet 1-29 (February 2020). 9 For mechanically attached components or partially-bonded insulation, the maximum design pressure for the selected assembly shall meet or exceed at least the Zone 1 PRIME design pressure determined in accordance with FBC Chapter 16. Elevated pressure zones shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29, Roofing Application Standard RAS 117 and Roofing Application Standard RAS 137. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (February 2020) for Zone 2/3 enhancements. 10 For assemblies with all components fully bonded, the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16. No rational analysis is permitted for these systems. 11 For mechanically attached components over existing decks, fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the minimum requirements for the system. Testing and analysis shall be in accordance with ANSI/SPRI FX-1 or Testing Application Standard TAS 105. 12 For bonded insulation or membrane over existing substrates in a re-roof (tear off) or recover installation, the existing deck or existing roof surface shall be examined for compatibility with the adhesive to be installed. If any surface conditions exist that bring system performance into question, field uplift testing shall be conducted on mock-ups of the proposed new roof assembly. For bonded insulation or membrane over existing substrates in a recover installation, the existing roof system shall be capable of resisting project design pressures on its own merit to the satisfaction of the Authority Having Jurisdiction, as documented through field uplift testing. Field uplift testing shall be in accordance with ASTM E907, FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124. 13 Refer to FBC 1511 for requirements and limitations regarding recover installations. For Structural Concrete Deck or Recover Applications using System Type C-1 the base insulation layer is optional and for System Type C-2, D-1 or D-2, the insulation is optional. Alternatively, an FBC Approved insulation board or coverboard may be used as a separation layer. Board products shall be preliminarily attached prior to roof cover installation (Note 5 herein). The separator component shall be documented as meeting FBC 1505 and, for foam plastic, FBC Chapter 26, when installed with the roof cover in Recover applications. 14 Lightweight insulating concrete (LWIC) shall be cast in accordance with FBC Section 1917 to the satisfaction of the Authority Having Jurisdiction. For systems where specific LWIC is referenced, refer to current LWIC Product Approval for specific deck construction and limitations. Unless otherwise noted, for systems where specific LWIC is not referenced, the minimum design mix shall be 300 psi. In all cases, the minimum top-coat thickness is 2-inches. For LWIC over structural concrete, reference is made to FBC Section 1917.4.1, Point 1. For “pre-existent” LWIC references, listings were established through testing over lightweight concrete cast using only foaming agent (ASTM C896), water and Portland cement (ASTM C150), with no proprietary additives, in accordance with procedures adopted by Miami-Dade BCCO (FBC CER1592). Use of these listings in new construction or re-roof (tear-off) applications is at the discretion of the Designer or Record and Authority Having Jurisdiction. NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R29 for FL2533-R28 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 29: 04/14/2022 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 4 of 70 15 For bonded membrane applications, unless otherwise noted, refer to the following. MEMBRANE / ADHESIVE COMBINATIONS REFERENCE LAYER MATERIAL APPLICATION SBS-CA1 Base Ply: Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Karnak No. 81 Cold Process Modified Bitumen Adhesive Brush Grade at 1 gal/square Note: Base ply cures overnight prior to application of the ply or cap ply. Ply: Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Cap Ply: Flintlastic FR-P, Flintlastic FR-P CoolStar, Flintlastic Premium FR-P, Flintlastic Premium FR-P CoolStar, Flintlastic GMS BP-CA2 Base Ply: Glasbase Base Sheet, All Weather/Empire Base Sheet, Flintlastic Base 20 Henry #903 Adhesive at 1.5 gal/square. SBS-CA2 Base Ply: Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Ply: Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Cap Ply: Flintlastic FR-P, Flintlastic FR-P CoolStar, Flintlastic Premium FR-P, Flintlastic Premium FR-P CoolStar, Flintlastic GMS BP-CA3 Base Ply: Glasbase Base Sheet, All Weather/Empire Base Sheet, Flintlastic Base 20 HB Fuller “Millennium Hurricane Force Membrane Adhesive”, beads spaced 6-inch o.c. SBS-CA3 Base Ply: Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Ply: Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Cap Ply: Flintlastic FR-P, Flintlastic FR-P CoolStar, Flintlastic Premium FR-P, Flintlastic Premium FR-P CoolStar, Flintlastic GMS SBS-CA4 Base Ply: Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base FlintBond Brush or Tropical Roofing Products #216 Modified Bitumen Adhesive at 1 to 1.5 gal/square. Note: Base ply cures overnight prior to application of the ply or cap ply. Ply: Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Cap Ply: Flintlastic FR-P, Flintlastic FR-P CoolStar, Flintlastic Premium FR-P, Flintlastic Premium FR-P CoolStar, Flintlastic GMS BP-AA Base Ply: Glasbase Base Sheet, All Weather/Empire Base Sheet, Flintlastic Base 20 hot asphalt at 20-40 lbs/square Ply: One or more Flintglas Ply 4 BP-AA2 Base Ply: Flintglas MS Cap (inverted) hot asphalt in 24-inch diameter spots in 30-inch grid pattern BP-AA3 Base Ply: Flintglas MS Cap (inverted) hot asphalt in 9-inch diameter spots in grid pattern noted herein. BP-AA4 Base Ply: Flintglas MS Cap (inverted) hot asphalt in 9-inch wide ribbons spaced as noted herein. SBS-AA Base Ply: Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base hot asphalt at 20-40 lbs/square Ply: One or more Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Cap Ply: Flintlastic FR-P, Flintlastic FR-P CoolStar, Flintlastic Premium FR-P, Flintlastic Premium FR-P CoolStar, Flintlastic GMS SBS-TA Base Ply: Flintlastic Ultra Poly SMS Base Sheet, Flintlastic Base 20 T torch-applied Ply: One or more Flintlastic Ultra Poly SMS Base Sheet, Flintlastic Base 20 T APP-TA Base Ply: One or more Flintlastic APP Base T, Flintlastic STA, Flintlastic STA Plus torch-applied Cap Ply: Flintlastic STA, Flintlastic STA Plus, Flintlastic GTA, Flintlastic GTA CoolStar, Flintlastic GTA-FR, Flintlastic GTA-FR CoolStar SBS-SA-H Base Ply: Black Diamond Base Sheet, Flintlastic Ultra Glass SA self-adhering (activated by overlying membrane) SBS-SA Base Ply: Flintlastic SA PlyBase, Flintlastic SA Mid Ply self-adhering Ply: Flintlastic SA PlyBase, Flintlastic SA Mid Ply Cap Ply: Flintlastic SA Cap, Flintlastic SA Cap CoolStar, Flintlastic SA Cap FR, Flintlastic SA Cap FR CoolStar NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R29 for FL2533-R28 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 29: 04/14/2022 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 5 of 70 16 Vapor barrier options for use over structural concrete deck followed by bonded insulation carry the following MDP limitations. The lesser of the MDP listings below vs. that for the selected assembly from TABLE 3A applies. VAPOR BARRIER OPTIONS, STRUCTURAL CONCRETE DECK, ADHERED INSULATION OPTION # PRIMER VAPOR BARRIER INSULATION ADHESIVE PER TABLE 3A MDP (PSF) TYPE ATTACH C-VB-1. FlintPrime QD Flintlastic SA PlyBase Self-adhering OB500, 12-inch o.c. -82.5 C-VB-2. None All Weather/Empire Base Sheet, 3-inch wide side laps and 6-inch wide end laps are sealed with HB Fuller “HB Fuller “Millennium Hurricane Force Lap and Flashing Adhesive” HB Fuller “Millennium Hurricane Force Membrane Adhesive HS”, max. 6-inch o.c. M-OSFA or M-PG1, 12-inch o.c. -82.5 C-VB-3. None Flintlastic Ultra Poly SMS Base Sheet, 3-inch wide side laps and 6-inch wide end laps are hot-air-welded, torch-welded or sealed with HB Fuller “HB Fuller “Millennium Hurricane Force Lap and Flashing Adhesive” HB Fuller “Millennium Hurricane Force Membrane Adhesive HS”, max. 6-inch o.c. M-OSFA or M-PG1, 12-inch o.c. -82.5 C-VB-4. FlintPrime QD Black Diamond Base Sheet, Flintlastic Ultra Glass SA or Flintlastic SA Cap Self-adhering M-OSFA or M-PG1, 12-inch o.c. -97.5 C-VB-5. FlintPrime QD Black Diamond Base Sheet, Flintlastic Ultra Glass SA or Flintlastic SA Cap Self-adhering M-OSFA or M-PG1, 6-inch o.c. -315.0 C-VB-6. FlintPrime QD Flintlastic GTA Torch-applied M-OSFA or M-PG1, 12-inch o.c. -420.0 C-VB-7. FlintPrime QD Flintlastic Base 20 T Torch-applied M-OSFA or M-PG1, 12-inch o.c. -495.0 17 The following products are interchangeable within the scope of this Evaluation Report. ACCEPTABLE ALTERNATES SUB-CATEGORY MANUFACTURER FBC FILE LISTED PRODUCT HEREIN ALTERNATE Adhesives H.B. Fuller Company FL1800 M-OSFA FlintFast QS Insulation Adhesive M-PG1 FlintFast LV Insulation Adhesive Roofing Fasteners Altenloh, Brinck and Co. U.S., Inc. FL4500 Trufast #12 DP FlintFast #12 Fastener Trufast #14 HD FlintFast #14 Fastener Trufast #15 EHD FlintFast #15 EHD Fastener Trufast 2” Barbed Metal Seam Plate FlintFast 2” Barbed Seam Plate Trufast 2.4” Barbed Metal Seam Plate FlintFast 2.4” Barbed Seam Plate Trufast 3” Metal Insulation Plate FlintFast 3” Insulation Plate Roofing Insulation Atlas Roofing FL17989 ACFoam II FlintBoard ISO ACFoam III FlintBoard ISO Cold Hunter Panels FL5968 H-Shield FlintBoardH ISO H-Shield CG FlintBoardH ISO Cold Georgia-Pacific Gypsum, LLC FL1250 DensDeck Prime DensDeck StormX Prime Roof Board 18 “MDP” = Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads. Refer to FBC 1609 for determination of design wind loads. NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R29 for FL2533-R28 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 29: 04/14/2022 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 6 of 70 TABLE 1A: WOOD DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER Sys. No. Deck (Note 1) Base Insulation Top Insulation Primer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply SELF-ADHERING SYSTEMS: W-1 Min. 15/32-inch APA rated CDX plywood, 24-inch span Min. 1.5-inch ACFoam II or H-Shield M-OSFA or M-PG1 (Optional) Additional layer(s) of base insulation and/or min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board. M-OSFA or M-PG1 FlintPrime QD SBS-SA (Optional) SBS- SA SBS-SA -60.0 W-2 Min. 15/32-inch APA rated CDX plywood, 24-inch span, blocked 48-inch o.c. Min. 1.5-inch ACFoam II or H-Shield M-OSFA or M-PG1, 6- inch o.c. (Optional) Additional layer(s) of base insulation and/or min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board. M-OSFA or M-PG1, 6- inch o.c. FlintPrime QD SBS-SA (Optional) SBS- SA SBS-SA -97.5 HYBRID SYSTEMS: W-3 Min. 15/32-inch APA rated CDX plywood, 24-inch span Min. 1.5-inch ACFoam II or H-Shield M-OSFA or M-PG1 (Optional) Additional layer(s) of base insulation and/or min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board. M-OSFA or M-PG1 None SBS-SA-H (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -60.0 W-4 Min. 15/32-inch APA rated CDX plywood, 24-inch span, blocked 48-inch o.c. Min. 1.5-inch ACFoam II or H-Shield M-OSFA or M-PG1, 6- inch o.c. (Optional) Additional layer(s) of base insulation and/or min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board. M-OSFA or M-PG1, 6- inch o.c. None SBS-SA-H (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -97.5 CONVENTIONAL SYSTEMS: W-5 Min. 15/32-inch APA rated CDX plywood, 24-inch span Min. 1.5-inch ACFoam II or H-Shield M-OSFA or M-PG1 Optional additional layers of base insulation, followed by min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board M-OSFA or M-PG1 None BP-AA, SBS- AA, SBS-TA or APP-TA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -60.0 W-6 Min. 15/32-inch APA rated CDX plywood, 24-inch span, blocked 48-inch o.c. Min. 1.5-inch ACFoam II or H-Shield M-OSFA or M-PG1, 6- inch o.c. Optional additional layers of base insulation, followed by min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board. M-OSFA or M-PG1, 6- inch o.c. None BP-AA, SBS- AA, SBS-TA or APP-TA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -97.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R29 for FL2533-R28 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 29: 04/14/2022 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 7 of 70 TABLE 1B: WOOD DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER Sys. No. Deck (Note 1) Anchor Sheet Base Insulation Top Insulation Primer Roof Cover (Note 15) MDP (psf) Type Fasteners Attach Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply SELF-ADHERING SYSTEMS: W-7 Min. 19/32- inch plywood, 24-inch span Glasbase Base Sheet, All Weather/Empire Base Sheet, Flintlastic Base 20, Poly SMS, Ultra Poly SMS or Flintglas MS Cap (inverted) 32 ga., 1-5/8- inch dia. tin caps with 11 ga. annular ring shank nails 9-inch o.c. in 4- inch lap and 12- inch o.c. in two (2), equally spaced, staggered center rows Min. 1.5-inch ACFoam II, ENRGY 3, H- Shield or Multi- Max FA3 hot asphalt Min. 0.25- inch DensDeck hot asphalt FlintPrime QD SBS-SA (Optional) SBS-SA SBS-SA -45.0* W-8 Min. 19/32- inch plywood, 24-inch span Glasbase Base Sheet, All Weather/Empire Base Sheet, Poly SMS or Ultra Poly SMS 32 ga., 1-5/8- inch dia. tin caps with 11 ga. annular ring shank nails 8-inch o.c. in 3- inch lap and 8- inch o.c. in three (3), equally spaced, staggered center rows Min. 1.5-inch ACFoam II, ENRGY 3, H- Shield or Multi- Max FA3 hot asphalt full coverage or M- OSFA, Insta Stik, OB500, Polyset BM or Polyset CRA, 4-inch o.c. Min. 0.25- inch DensDeck hot asphalt full coverage or M- OSFA, Insta Stik, OB500, Polyset BM or Polyset CRA, 6-inch o.c. FlintPrime QD SBS-SA (Optional) SBS-SA SBS-SA -52.5 W-9 Min. 19/32- inch plywood, 24-inch span Flintglas MS Cap (inverted) 32 ga., 1-5/8- inch dia. tin caps with 11 ga. annular ring shank nails 8-inch o.c. in 3- inch lap and 8- inch o.c. in three (3), equally spaced, staggered center rows Min. 1.5-inch ACFoam II, ENRGY 3, H- Shield or Multi- Max FA3 hot asphalt Min. 0.25- inch DensDeck hot asphalt FlintPrime QD SBS-SA (Optional) SBS-SA SBS-SA -52.5 W-10 Min. 19/32- inch plywood, 24-inch span Glasbase Base Sheet, All Weather/Empire Base Sheet, Poly SMS or Ultra Poly SMS 32 ga., 1-5/8- inch dia. tin caps with 11 ga. annular ring shank nails 8-inch o.c. in 3- inch lap and 8- inch o.c. in three (3), equally spaced, staggered center rows (Optional) Min. 1.5-inch ACFoam II, ENRGY 3, H- Shield or Multi- Max FA3 hot asphalt full coverage or M- OSFA, Insta Stik, OB500, Polyset BM or Polyset CRA, 4-inch o.c. Min. 0.25- inch SECUROCK Gypsum- Fiber Roof Board hot asphalt full coverage or M- OSFA, Insta Stik, OB500, Polyset BM or Polyset CRA, 6-inch o.c. FlintPrime QD SBS-SA (Optional) SBS-SA SBS-SA -60.0 W-11 Min. 19/32- inch plywood, 24-inch span Flintglas MS Cap (inverted) 32 ga., 1-5/8- inch dia. tin caps with 11 ga. annular ring shank nails 8-inch o.c. in 3- inch lap and 8- inch o.c. in three (3), equally spaced, staggered center rows (Optional) Min. 1.5-inch ACFoam II, ENRGY 3, H- Shield or Multi- Max FA3 hot asphalt Min. 0.25- inch SECUROCK Gypsum- Fiber Roof Board hot asphalt FlintPrime QD SBS-SA (Optional) SBS-SA SBS-SA -60.0 HYBRID SYSTEMS: W-12 Min. 19/32- inch plywood, 24-inch span Glasbase Base Sheet, All Weather/Empire Base Sheet, Flintlastic Base 20, Poly SMS, Ultra Poly SMS or Flintglas MS Cap (inverted) 32 ga., 1-5/8- inch dia. tin caps with 11 ga. annular ring shank nails 9-inch o.c. in 4- inch lap and 12- inch o.c. in two (2), equally spaced, staggered center rows Min. 1.5-inch ACFoam II, ENRGY 3, H- Shield or Multi- Max FA3 hot asphalt None N/A None SBS-SA-H (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP- TA -45.0* NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R29 for FL2533-R28 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 29: 04/14/2022 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 8 of 70 TABLE 1B: WOOD DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER Sys. No. Deck (Note 1) Anchor Sheet Base Insulation Top Insulation Primer Roof Cover (Note 15) MDP (psf) Type Fasteners Attach Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply W-13 Min. 19/32- inch plywood at max. 24- inch Glasbase Base Sheet or Flintglas MS Cap (inverted) 32 ga., 1-5/8- inch dia. tin caps with 11 ga. annular ring shank nails 8-inch o.c. in 3- inch lap and 8- inch o.c. in three (3), equally spaced, staggered center rows Min. 1.5-inch ACFoam II, ENRGY 3, H- Shield or Multi- Max FA3 hot asphalt None N/A None SBS-SA-H (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP- TA -60.0 CONVENTIONAL SYSTEMS: W-14 Min. 19/32- inch plywood, 24-inch span Glasbase Base Sheet, All Weather/Empire Base Sheet, Flintlastic Base 20, Poly SMS, Ultra Poly SMS or Flintglas MS Cap (inverted) 32 ga., 1-5/8- inch dia. tin caps with 11 ga. annular ring shank nails 9-inch o.c. in 4- inch lap and 12- inch o.c. in two (2), equally spaced, staggered center rows Min. 1.5-inch ACFoam II, ENRGY 3, H- Shield or Multi- Max FA3 hot asphalt Min. 0.25- inch DensDeck hot asphalt FlintPrime QD BP-AA, SBS-AA, SBS-TA or APP-TA (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP- TA -45.0* W-15 Min. 19/32- inch plywood, 24-inch span Glasbase Base Sheet, All Weather/Empire Base Sheet, Poly SMS or Ultra Poly SMS 32 ga., 1-5/8- inch dia. tin caps with 11 ga. annular ring shank nails 8-inch o.c. in 3- inch lap and 8- inch o.c. in three (3), equally spaced, staggered center rows Min. 1.5-inch ACFoam II, ENRGY 3, H- Shield or Multi- Max FA3 hot asphalt full coverage or M- OSFA, Insta Stik, OB500, Polyset BM or Polyset CRA, 4-inch o.c. Min. 0.25- inch DensDeck hot asphalt full coverage or M- OSFA, Insta Stik, OB500, Polyset BM or Polyset CRA, 6-inch o.c. FlintPrime QD BP-AA, SBS-AA, SBS-TA or APP-TA (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP- TA -52.5 W-16 Min. 19/32- inch plywood, 24-inch span Glasbase Base Sheet, All Weather/Empire Base Sheet, Poly SMS or Ultra Poly SMS 32 ga., 1-5/8- inch dia. tin caps with 11 ga. annular ring shank nails 8-inch o.c. in 3- inch lap and 8- inch o.c. in three (3), equally spaced, staggered center rows (Optional) Min. 1.5-inch ACFoam II, ENRGY 3, H- Shield or Multi- Max FA3 hot asphalt full coverage or M- OSFA, Insta Stik, OB500, Polyset BM or Polyset CRA, 4-inch o.c. Min. 0.25- inch SECUROCK Gypsum- Fiber Roof Board hot asphalt full coverage or M- OSFA, Insta Stik, OB500, Polyset BM or Polyset CRA, 6-inch o.c. None BP-AA, SBS-AA, SBS-TA or APP-TA (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP- TA -60.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R29 for FL2533-R28 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 29: 04/14/2022 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 9 of 70 TABLE 1C: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE B-1: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Fasteners Attach Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply HYBRID SYSTEMS: W-17 Min. 15/32-inch plywood, 24- inch span Min. 1.5-inch ACFoam II or H- Shield Trufast #12 DP or #14 HD with Trufast 3”Metal Insulation Plates 1 per 1.3 ft2 Min. 1.5-inch ACFoam II or H-Shield hot asphalt, M-OSFA, M-PG1 Insta Stik, OB500 SBS-SA-H (Optional) APP-TA APP-TA -67.5 CONVENTIONAL SYSTEMS: W-18 Min. 23/32-inch plywood, 24- inch span Min. 1.5-inch ACFoam II, ENRGY 3 or H-Shield Note 2 1 per 2.0 ft2 Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation, min. 0.75-inch FescoBoard (homogeneous) hot asphalt BP-AA or SBS-AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA or APP-TA -45.0* W-19 Min. 23/32-inch plywood, 24- inch span Min. 1.5-inch ACFoam II, ENRGY 3 or H-Shield Note 2 1 per 2.0 ft2 Min. 0.25-inch DensDeck, DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board hot asphalt BP-AA, SBS- AA, SBS-TA or APP-TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA or APP-TA -45.0* W-20 Min. 15/32-inch plywood, 24- inch span Min. 1.5-inch ACFoam II or H- Shield Trufast #12 DP or #14 HD with Trufast 3”Metal Insulation Plates 1 per 1.3 ft2 Optional additional layer(s) of base insulation followed by Min. 0.25- inch SECUROCK Gypsum-Fiber Roof board hot asphalt, M-OSFA, M-PG1, Insta Stik, OB500 APP-TA (Optional) APP-TA APP-TA -90.0 TABLE 1D: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer Top Insulation Layer Primer Roof Cover (Note 15) MDP (psf) Type Fasteners Attach Base Ply Ply Cap Ply SELF-ADHERING SYSTEMS: W-21 Min. 15/32-inch plywood, 24-inch span (Optional) One or more layers, any combination, loose laid Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Trufast #12 DP or #14 HD with Trufast 3” Metal Insulation Plate 1 per 3.2 ft2 None SBS-SA (Optional) SBS- SA SBS-SA -30.0* W-22 Min. 19/32-inch plywood, 24-inch span (Optional) One or more layers, any combination, loose laid Min. 0.25-inch DensDeck Note 2 1 per 1.3 ft2 FlintPrime QD SBS-SA (Optional) SBS- SA SBS-SA -45.0 W-23 Min. 19/32-inch plywood, 24-inch span (Optional) One or more layers, any combination, loose laid Min. 3/8-inch SECUROCK Gypsum-Fiber Roof Board Trufast #12 DP or #14 HD with Trufast 3” Metal Insulation Plate 1 per 2.7 ft2 None SBS-SA (Optional) SBS- SA SBS-SA -45.0* W-24 Min. 19/32-inch plywood, 24-inch span (Optional) One or more layers, any combination, loose laid Min. 1.5-inch ACFoam II, ENRGY 3, H-Shield or Multi- Max FA3 Trufast #12 DP or #14 HD with Trufast 3” Metal Insulation Plate 1 per 2.0 ft2 FlintPrime QD SBS-SA (Optional) SBS- SA SBS-SA -45.0* W-25 Min. 15/32-inch plywood, 24-inch span (Optional) One or more layers, any combination, loose laid Min. 1.5-inch ACFoam II Trufast #14 HD with Trufast 3” Metal Insulation Plate 1 per 1.6 ft2 FlintPrime QD SBS-SA (Optional) SBS- SA SBS-SA -52.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R29 for FL2533-R28 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 29: 04/14/2022 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 10 of 70 TABLE 1D: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer Top Insulation Layer Primer Roof Cover (Note 15) MDP (psf) Type Fasteners Attach Base Ply Ply Cap Ply W-26 Min. 19/32-inch plywood, 24-inch span (Optional) One or more layers, any combination, loose laid Min. 1.5-inch ACFoam II, ENRGY 3, H-Shield or Multi- Max FA3 Note 2 1 per 1.45 ft2 FlintPrime QD SBS-SA (Optional) SBS- SA SBS-SA -60.0 HYBRID SYSTEMS: W-27 Min. 15/32-inch plywood, 24-inch span (Optional) One or more layers, any combination, loose laid Min. 0.25-inch DensDeck, DensDeck Prime Trufast #12 DP or #14 HD with Trufast 3” Metal Insulation Plate 1 per 2.0 ft2 None SBS-SA- H (Optional) BP- AA, SBS-AA, SBS-TA or APP- TA SBS-AA or APP-TA -30.0* W-28 Min. 15/32-inch plywood, 24-inch span (Optional) One or more layers, any combination, loose laid Min. 1.5-inch ACFoam II Trufast #14 HD with Trufast 3” Metal Insulation Plate 1 per 1.6 ft2 None SBS-SA- H (Optional) SBS- TA or APP-TA APP-TA -52.5 W-29 Min. 15/32-inch plywood, 24-inch span (Optional) One or more layers, any combination, loose laid Min. 1.5-inch ACFoam II, ENRGY 3 or Multi-Max FA3 Note 2 1 per 1.3 ft2 None SBS-SA- H (Optional) BP- AA or SBS-AA SBS-AA -52.5 W-30 Min. 19/32-inch plywood, 24-inch span (Optional) One or more layers, any combination, loose laid Min. 1.5-inch ACFoam II or H- Shield Note 2 1 per 1.45 ft2 None SBS-SA- H (Optional) BP- AA, SBS-AA, SBS-TA or APP- TA SBS-AA or APP-TA -60.0 W-31 Min. 15/32-inch plywood, 24-inch span (Optional) Min. 1.5-inch, One or more layers, any combination, loose laid Min. 1.5-inch ACFoam II or H- Shield Trufast #12 DP or #14 HD with Trufast 3” Metal Insulation Plate 1 per 1.3 ft2 None SBS-SA- H (Optional) SBS- AA, SBS-TA or APP-TA SBS-AA or APP-TA -75.0 W-32 Min. 19/32-inch plywood, 24-inch span (Optional) One or more layers, any combination, loose laid Min. 1.5-inch ACFoam II, ENRGY 3 or Multi-Max FA3 Note 2 1 per 1.3 ft2 None SBS-SA- H (Optional) SBS- TA or APP-TA APP-TA -82.5 CONVENTIONAL SYSTEMS: W-33 Min. 23/32-inch plywood, 24-inch span (Optional) One or more layers, any combination, loose laid Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation, min. 0.75-inch FescoBoard (homogeneous) Note 2 1 per 2.0 ft2 None BP-AA or SBS-AA (Optional) BP- AA, SBS-AA, SBS-TA or APP- TA SBS-AA or APP-TA -45.0* W-34 Min. 15/32-inch plywood, 24-inch span (Optional) One or more layers, any combination, loose laid Min. 0.25-inch DensDeck, DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Trufast #12 DP or #14 HD with Trufast 3” Metal Insulation Plate 1 per 2.0 ft2 None BP-AA, SBS-AA, SBS-TA or APP- TA (Optional) BP- AA, SBS-AA, SBS-TA or APP- TA SBS-AA or APP-TA -45.0* W-35 Min. 15/32-inch plywood, 24-inch span (Optional for Recover) Min. 1.5-inch, One or more layers, any combination, loose laid Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Trufast #12 DP or #14 HD with Trufast 3” Metal Insulation Plate 1 per 1.45 ft2 None APP-TA (Optional) APP- TA APP-TA -60.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R29 for FL2533-R28 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 29: 04/14/2022 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 11 of 70 TABLE 1D: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer Top Insulation Layer Primer Roof Cover (Note 15) MDP (psf) Type Fasteners Attach Base Ply Ply Cap Ply W-36 Min. 19/32-inch plywood, 24-inch span Min. 2-inch ACFoam II, ENRGY 3 or H-Shield, loose laid. Min. 0.5-inch SECUROCK Gypsum-Fiber Roof Board Trufast #12 DP or #14 HD with Trufast 3” Metal Insulation Plate 1 per 1.8 ft2 None BP-AA, SBS-AA, SBS-TA or APP- TA (Optional) BP- AA, SBS-AA, SBS-TA or APP- TA SBS-AA or APP-TA -60.0 W-37 Min. 15/32-inch plywood, 24-inch span (Optional for Recover) Min. 1.5-inch, One or more layers, any combination, loose laid Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Trufast #12 DP or #14 HD with Trufast 3” Metal Insulation Plate 1 per 1.3 ft2 None APP-TA (Optional) APP- TA APP-TA -67.5 TABLE 1E: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE D-2: INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Insulation Layer(s) (Note 13) Base Sheet Primer Roof Cover (Note 15) MDP (psf) Type Attach Type Fasteners Attach Base Ply Cap Ply SELF-ADHERING SYSTEMS: W-38 Min. 19/32- inch plywood, 24-inch span Min. 1.5-inch, One or more layers, any combination Prelim. Attach Flintlastic SA NailBase Note 2 8-inch o.c. at min. 3-inch lap and 8-inch o.c. in two (2), equally spaced, staggered center rows FlintPrime QD at stress plates (Optional) SBS-SA SBS-SA -82.5* W-39 Min. 15/32- inch plywood, 24-inch span Min. 1.5-inch, One or more layers, any combination Prelim. Attach Flintlastic SA NailBase OMG #14 HD with OMG 3 in. Round Metal Plate or Trufast #12 DP or #14 HD with Trufast 3” Metal Insulation Plate 6-inch o.c. at min. 2-inch lap and 6-inch o.c. in three (3), equally spaced, staggered center rows FlintPrime QD at stress plates (Optional) SBS-SA SBS-SA -97.5* W-40 Min. 15/32- inch plywood, 24-inch span Min. 1.5-inch, One or more layers, any combination Prelim. Attach Flintlastic SA NailBase OMG #14 HD with OMG 3 in. Round Metal Plate or Trufast #12 DP or #14 HD with Trufast 3” Metal Insulation Plate 6-inch o.c. at min. 2-inch lap and 6-inch o.c. in four (4), equally spaced, staggered center rows FlintPrime QD at stress plates (Optional) SBS-SA SBS-SA -127.5* HYBRID SYSTEMS: W-41 Min. 15/32- inch plywood, 24-inch span Min. 1.5-inch, One or more layers, any combination Prelim. Attach Glasbase Base Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet OMG #14 HD with OMG 3 in. Round Metal Plate or Trufast #12 DP or #14 HD with Trufast 3” Metal Insulation Plate 6-inch o.c. at 4-inch lap and 6- inch o.c. in three (3), equally spaced, staggered center rows FlintPrime QD at stress plates SBS-SA-H SBS-AA or APP-TA -97.5 W-42 Min. 19/32- inch plywood, 24-inch span Min. 1.5-inch, One or more layers, any combination Prelim. Attach Glasbase Base Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet Note 2 7-inch o.c. at 3-inch lap and 7- inch o.c. in three (3), equally spaced, staggered center rows None SBS-SA-H SBS-AA or APP-TA -105.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R29 for FL2533-R28 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 29: 04/14/2022 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 12 of 70 TABLE 1E: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE D-2: INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Insulation Layer(s) (Note 13) Base Sheet Primer Roof Cover (Note 15) MDP (psf) Type Attach Type Fasteners Attach Base Ply Cap Ply W-43 Min. 15/32- inch plywood, 24-inch span Min. 1.5-inch, One or more layers, any combination Prelim. Attach Glasbase Base Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet OMG #14 HD with OMG 3 in. Round Metal Plate or Trufast #12 DP or #14 HD with Trufast 3” Metal Insulation Plate 6-inch o.c. at 4-inch lap and 6- inch o.c. in four (4), equally spaced, staggered center rows FlintPrime QD at stress plates SBS-SA-H SBS-AA or APP-TA -127.5 CONVENTIONAL SYSTEMS: W-44 Min. 23/32- inch plywood, 24-inch span Min. 1.5-inch, One or more layers, any combination Prelim. Attach Glasbase Base Sheet, All Weather/Empire Base Sheet, Flintlastic Base 20 or Flintglas MS Cap (inverted) Note 2 12-inch o.c. at 4-inch lap and 36-inch o.c. in two (2), equally spaced, staggered center rows None BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP-TA -30.0* W-45 Min. 23/32- inch plywood, 24-inch span Min. 1.5-inch, One or more layers, any combination Prelim. Attach Glasbase Base Sheet, All Weather/Empire Base Sheet, Flintlastic Base 20 or Flintglas MS Cap (inverted) Note 2 12-inch o.c. at 4-inch lap and 24-inch o.c. in two (2), equally spaced, staggered center rows None BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP-TA -45.0* W-46 Min. 23/32- inch plywood, 24-inch span Min. 1.5-inch, One or more layers, any combination Prelim. Attach Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet Note 2 12-inch o.c. at 4-inch lap and 36-inch o.c. in two (2), equally spaced, staggered center rows None BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP-TA -45.0* W-47 Min. 15/32- inch plywood, 24-inch span Min. 1.5-inch, One or more layers, any combination Prelim. Attach Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet or Flintglas MS Cap (inverted) OMG #14 HD with OMG 3 in. Round Metal Plate or Trufast #12 DP or #14 HD with Trufast 3” Metal Insulation Plate 6-inch o.c. at 4-inch lap and 6- inch o.c. in three (3), equally spaced, staggered center rows. None (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP-TA -97.5 W-48 Min. 15/32- inch plywood, 24-inch span Min. 1.5-inch, One or more layers, any combination Prelim. Attach Flintlastic APP Base T OMG #14 HD with OMG 3 in. Round Metal Plates 6-inch o.c. at 4-inch lap and 6- inch o.c. in three (3), equally spaced, staggered center rows. None APP-TA APP-TA -97.5 W-49 Min. 15/32- inch plywood, 24-inch span One or more layers, any thickness or combination Prelim. Attach Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet or Flintglas MS Cap (inverted) Trufast #14 HD with Trufast 3” Metal Insulation Plate 8-inch o.c. at 4-inch lap and 8- inch o.c. at three (3) equally spaced, staggered center rows None (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP-TA -97.5 W-50 Min. 19/32- inch plywood, 24-inch span Min. 1.5-inch, One or more layers, any combination Prelim. Attach Glasbase Base Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet or Flintglas MS Cap (inverted) Note 2 7-inch o.c. at 3-inch lap and 7- inch o.c. in three (3), equally spaced, staggered center rows None BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP-TA -105.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R29 for FL2533-R28 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 29: 04/14/2022 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 13 of 70 TABLE 1E: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE D-2: INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Insulation Layer(s) (Note 13) Base Sheet Primer Roof Cover (Note 15) MDP (psf) Type Attach Type Fasteners Attach Base Ply Cap Ply W-51 Min. 19/32- inch plywood, 24-inch span Min. 1.5-inch, One or more layers, any combination Prelim. Attach Flintlastic APP Base T Dekfast DF-#14-PH3 with PLT-H-2-7/8 or OMG #14 HD with OMG 3 in. Round Metal Plate 7-inch o.c. at 3-inch lap and 7- inch o.c. in three (3), equally spaced, staggered center rows None APP-TA APP-TA -105.0 W-52 Min. 15/32- inch plywood, 24-inch span Min. 1.5-inch, One or more layers, any combination Prelim. Attach Glasbase Base Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet or Flintglas MS Cap (inverted) OMG #14 HD with OMG 3 in. Round Metal Plate or Trufast #12 DP or #14 HD with Trufast 3” Metal Insulation Plate 6-inch o.c. at 4-inch lap and 6- inch o.c. in four (4), equally spaced, staggered center rows. None (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP-TA -127.5 W-53 Min. 15/32- inch plywood, 24-inch span Min. 1.5-inch, One or more layers, any combination Prelim. Attach Flintlastic APP Base T OMG #14 HD with OMG 3 in. Round Metal Plates 6-inch o.c. at 4-inch lap and 6- inch o.c. in four (4), equally spaced, staggered center rows. None APP-TA APP-TA -127.5 COLD-APPLIED SYSTEMS: W-54 Min. 15/32- inch plywood, 24-inch span Min. 1-inch, One or more layers, any combination Loose- laid Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet or Flintglas MS Cap (inverted) Trufast #12 DP or #14 HD with Trufast 3” Metal Insulation Plate 8-inch o.c. at 4-inch lap and 8- inch o.c. in three (3), equally spaced, staggered center rows None (Optional) SBS-CA1 SBS-CA1 -52.5 TABLE 1F: WOOD DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE E-2: NON-INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Base Sheet Primer Roof Cover (Note 15) MDP (psf) Base Fasteners Attach Base Ply Cap Ply SELF-ADHERING SYSTEMS: W-55 Min. 15/32-inch plywood, 24-inch span Flintlastic SA NailBase Simplex MAXX Cap 9-inch o.c. at min. 3-inch lap and 12-inch o.c. in two (2), equally spaced, staggered center rows FlintPrime QD at stress plates (Optional) SBS-SA SBS-SA -45.0* W-56 Min. 15/32-inch plywood, 24-inch span Flintlastic SA NailBase Min. 1-inch long, 12 ga. Simplex Metal Cap Nails 6-inch o.c. at min. 2-inch lap and 6-inch o.c. in four (4), equally spaced, staggered center rows None (Optional) SBS-SA SBS-SA -52.5 W-57 Min. 19/32-inch plywood, 24-inch span Flintlastic SA NailBase 32 ga., 1-5/8-inch dia. tin caps with 11 ga. annular ring shank nails 8-inch o.c. at min. 2-inch lap and 8-inch o.c. in three (3), equally spaced, staggered center rows None (Optional) SBS-SA SBS-SA -52.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R29 for FL2533-R28 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 29: 04/14/2022 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 14 of 70 TABLE 1F: WOOD DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE E-2: NON-INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Base Sheet Primer Roof Cover (Note 15) MDP (psf) Base Fasteners Attach Base Ply Cap Ply W-58 APA rated, min. 7/16 CAT, 0.418 in., Exposure 1, OSB, 24-inch span Flintlastic SA NailBase Simplex MAXX Cap 8-inch o.c. at min. 3-inch lap and 8-inch o.c. in three (3), equally spaced, staggered center rows FlintPrime QD at stress plates (Optional) Flintlastic SA Mid Ply, self- adhering SBS-SA -52.5 W-59 Min. 19/32-inch plywood, 24-inch span Flintlastic SA NailBase 32 ga., 1-5/8-inch dia. tin caps with 11 ga. annular ring shank nails 8-inch o.c. at min. 2-inch lap and 8-inch o.c. in three (3), equally spaced, staggered center rows None (Optional) SBS-SA SBS-SA -60.0 W-60 Min. 15/32-inch plywood, 24-inch span Flintlastic SA NailBase Simplex MAXX Cap 8-inch o.c. at min. 3-inch lap and 8-inch o.c. in three (3), equally spaced, staggered center rows FlintPrime QD at stress plates (Optional) SBS-SA SBS-SA -67.5 W-61 Min. 19/32-inch plywood, 24-inch span Flintlastic SA NailBase 32 ga., 1-5/8-inch dia. tin caps with 11 ga. annular ring shank nails 6-inch o.c. at min. 2-inch lap and 6-inch o.c. in four (4), equally spaced, staggered center rows None (Optional) SBS-SA SBS-SA -75.0 W-62 Min. 15/32-inch plywood, 24-inch span Flintlastic SA NailBase Cap nails: 1-inch diameter, 0.032- inch metal cap with 0.120" shank diameter, annular ring shank nails 7-inch o.c. at min. 4-inch laps and 7-inch o.c. in five (5), equally spaced, staggered center rows None (Optional) SBS-SA SBS-SA -75.0 W-63 Min. 19/32-inch plywood, 24-inch span Flintlastic SA NailBase 32 ga., 1-5/8-inch dia. tin caps with 11 ga. annular ring shank nails 4-inch o.c. at min. 2-inch lap and 4-inch o.c. in four (4), equally spaced, staggered center rows None (Optional) SBS-SA SBS-SA -105.0 HYBRID SYSTEMS: W-64 Min. 19/32-inch plywood, 24-inch span Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet 32 ga., 1-5/8-inch dia. tin caps with 11 ga. annular ring shank nails 9-inch o.c. at 4-inch lap and 12-inch o.c. in two (2), equally spaced, staggered center rows None SBS-SA-H SBS-AA or APP-TA -45.0* W-65 Min. 15/32-inch plywood, 24-inch span Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet Min. 1-inch long, 12 ga. Simplex Metal Cap Nails 6-inch o.c. at 3-inch lap and 6-inch o.c. in four (4), equally spaced, staggered center rows None SBS-SA-H SBS-AA or APP-TA -52.5 W-66 Min. 19/32-inch plywood, 24-inch span Glasbase Base Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet 32 ga., 1-5/8-inch dia. tin caps with 11 ga. annular ring shank nails 8-inch o.c. at 4-inch lap and 8-inch o.c. in three (3), equally spaced, staggered center rows None SBS-SA-H SBS-AA or APP-TA -52.5 W-67 Min. 19/32-inch plywood, 24-inch span Glasbase Base Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet 32 ga., 1-5/8-inch dia. tin caps with 11 ga. annular ring shank nails 8-inch o.c. at 4-inch lap and 8-inch o.c. in three (3), equally spaced, staggered center rows None SBS-SA-H SBS-AA or APP-TA -60.0 W-68 Min. 19/32-inch plywood, 24-inch span Glasbase Base Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet 32 ga., 1-5/8-inch dia. tin caps with 11 ga. annular ring shank nails 6-inch o.c. at 4-inch lap and 6-inch o.c. in four (4), equally spaced, staggered center rows None SBS-SA-H SBS-AA or APP-TA -82.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R29 for FL2533-R28 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 29: 04/14/2022 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 15 of 70 TABLE 1F: WOOD DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE E-2: NON-INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Base Sheet Primer Roof Cover (Note 15) MDP (psf) Base Fasteners Attach Base Ply Cap Ply W-69 Min. 19/32-inch plywood, 24-inch span Glasbase Base Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet 32 ga., 1-5/8-inch dia. tin caps with 11 ga. annular ring shank nails 4-inch o.c. at 3-inch lap and 4-inch o.c. in four (4), equally spaced, staggered center rows None SBS-SA-H SBS-AA or APP-TA -105.0 CONVENTIONAL SYSTEMS: W-70 Min. 19/32-inch plywood, 24-inch span Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet or Flintglas MS Cap (inverted) 32 ga., 1-5/8-inch dia. tin caps with 11 ga. annular ring shank nails 9-inch o.c. at 4-inch lap and 12-inch o.c. in two (2), equally spaced, staggered center rows None BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP-TA -45.0* W-71 Min. 15/32-inch plywood, 24-inch span Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet, Flintlastic Poly SMS Base Sheet or Flintglas MS Cap (inverted) Simplex MAXX Cap 9-inch o.c. at 2-inch lap and 18-inch o.c. in two (2), equally spaced, staggered center rows None (Optional) BP- AA, SBS-AA, SBS-TA or APP-TA SBS-AA or APP-TA -45.0* W-72 Min. 15/32-inch plywood, 24-inch span Flintlastic APP Base T Simplex MAXX Cap 9-inch o.c. at 2-inch lap and 18-inch o.c. in two (2), equally spaced, staggered center rows None (Optional) APP-TA APP-TA -45.0* W-73 Min. 15/32-inch plywood, 24-inch span Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet or Flintglas MS Cap (inverted) Min. 1-inch long, 12 ga. Simplex Metal Cap Nails 6-inch o.c. at 3-inch lap and 6-inch o.c. in four (4), equally spaced, staggered center rows None (Optional) BP- AA, SBS-AA, SBS-TA or APP-TA SBS-AA or APP-TA -52.5 W-74 Min. 19/32-inch plywood, 24-inch span Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet or Flintglas MS Cap (inverted) 32 ga., 1-5/8-inch dia. tin caps with 11 ga. annular ring shank nails 8-inch o.c. at 4-inch lap and 8-inch o.c. in three (3), equally spaced, staggered center rows None BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP-TA -52.5 W-75 Min. 15/32-inch plywood, 24-inch span Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet, Flintlastic Poly SMS Base Sheet or Flintglas MS Cap (inverted) Simplex MAXX Cap 9-inch o.c. at 2-inch lap and 12-inch o.c. in two (2), equally spaced, staggered center rows None (Optional) BP- AA, SBS-AA, SBS-TA or APP-TA SBS-AA or APP-TA -52.5 W-76 Min. 15/32-inch plywood, 24-inch span Flintlastic APP Base T Simplex MAXX Cap 9-inch o.c. at 2-inch lap and 12-inch o.c. in two (2), equally spaced, staggered center rows None (Optional) APP-TA APP-TA -52.5 W-77 Min. 19/32-inch plywood, 24-inch span Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet or Flintglas MS Cap (inverted) 32 ga., 1-5/8-inch dia. tin caps with 11 ga. annular ring shank nails 8-inch o.c. at 4-inch lap and 8-inch o.c. in three (3), equally spaced, staggered center rows None BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP-TA -60.0 W-78 Min. 15/32-inch plywood, 24-inch span Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet or Flintglas MS Cap (inverted) Cap nails: 1-inch diameter, 0.032- inch metal cap with 0.120-inch shank diameter, annular ring shank nails. 6-inch o.c. at 4-inch lap and 6-inch o.c. at five (5) equally spaced, staggered center rows None (Optional) BP- AA, SBS-AA or SBS-TA SBS-AA -67.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R29 for FL2533-R28 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 29: 04/14/2022 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 16 of 70 TABLE 1F: WOOD DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE E-2: NON-INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Base Sheet Primer Roof Cover (Note 15) MDP (psf) Base Fasteners Attach Base Ply Cap Ply W-79 Min. 19/32-inch plywood, 24-inch span Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet or Flintglas MS Cap (inverted) 32 ga., 1-5/8-inch dia. tin caps with 11 ga. annular ring shank nails 6-inch o.c. at 4-inch lap and 6-inch o.c. in four (4), equally spaced, staggered center rows None BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP-TA -82.5 W-80 Min. 15/32-inch plywood, 24-inch span Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet, Flintlastic Poly SMS Base Sheet or Flintglas MS Cap (inverted) Simplex MAXX Cap 6-inch o.c. at 2-inch lap and 6-inch o.c. in two (2), equally spaced, staggered center rows None (Optional) BP- AA, SBS-AA, SBS-TA or APP-TA SBS-AA or APP-TA -90.0 W-81 Min. 15/32-inch plywood, 24-inch span Flintlastic APP Base T Simplex MAXX Cap 6-inch o.c. at 2-inch lap and 6-inch o.c. in two (2), equally spaced, staggered center rows None (Optional) APP-TA APP-TA -90.0 W-82 Min. 19/32-inch plywood, 24-inch span Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet or Flintglas MS Cap (inverted) 32 ga., 1-5/8-inch dia. tin caps with 11 ga. annular ring shank nails 4-inch o.c. at 3-inch lap and 4-inch o.c. in four (4), equally spaced, staggered center rows None BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP-TA -105.0 W-83 Min. 15/32-inch plywood, 24-inch span Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet, Flintlastic Poly SMS Base Sheet or Flintglas MS Cap (inverted) Simplex MAXX Cap 6-inch o.c. at 2-inch lap and 6-inch o.c. in three (3), equally spaced, staggered center rows None (Optional) BP- AA, SBS-AA, SBS-TA or APP-TA SBS-AA or APP-TA -105.0 W-84 Min. 15/32-inch plywood, 24-inch span Flintlastic APP Base T Simplex MAXX Cap 6-inch o.c. at 2-inch lap and 6-inch o.c. in three (3), equally spaced, staggered center rows None (Optional) APP-TA APP-TA -105.0 TABLE 1G: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE E-2: NON-INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Base Sheet Primer Roof Cover (Note 15) MDP (psf) Base Fasteners Attach Base Ply Cap Ply SELF-ADHERING SYSTEMS: W-85 APA rated, min. 7/16 CAT, 0.418 in., Exposure 1, OSB, 24-inch span Flintlastic SA NailBase Trufast Versa Fasteners & Plates, two (2) screws per plate at 180° from each other* 9-inch o.c. at min. 3-inch lap and 12-inch o.c. in two (2), equally spaced, staggered center rows FlintPrime QD at stress plates (Optional) Flintlastic SA Mid Ply, self- adhering SBS-SA -60.0* Note: *For re-roof (tear-off) or recover applications, field withdrawal resistance testing (Note 11) shall yield minimum 109 lbf. Additional Versa-Fast Fasteners within each Versa-Fast Plate may be utilized to produce minimum withdrawal resistance. For recover installations, screws shall be of sufficient length for minimum 1” penetration through OSB sheathing. W-86 Min. 19/32-inch plywood, 24-inch span Flintlastic SA NailBase Note 2 8-inch o.c. at min. 3-inch lap and 8-inch o.c. in two (2), equally spaced, staggered center rows FlintPrime QD at stress plates (Optional) SBS-SA SBS-SA -82.5* NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R29 for FL2533-R28 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 29: 04/14/2022 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 17 of 70 TABLE 1G: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE E-2: NON-INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Base Sheet Primer Roof Cover (Note 15) MDP (psf) Base Fasteners Attach Base Ply Cap Ply W-87 Min. 15/32-inch plywood, 24-inch span Flintlastic SA NailBase OMG #14 HD with OMG 3 in. Round Metal Plate or Trufast #12 DP or #14 HD with Trufast 3” Metal Insulation Plate 6-inch o.c. at min. 2-inch lap and 6-inch o.c. in three (3), equally spaced, staggered center rows FlintPrime QD at stress plates (Optional) SBS-SA SBS-SA -97.5* W-88 Min. 15/32-inch plywood, 24-inch span Flintlastic SA NailBase OMG #14 HD with OMG 3 in. Round Metal Plate or Trufast #12 DP or #14 HD with Trufast 3” Metal Insulation Plate 6-inch o.c. at min. 2-inch lap and 6-inch o.c. in four (4), equally spaced, staggered center rows FlintPrime QD at stress plates (Optional) SBS-SA SBS-SA -127.5* HYBRID SYSTEMS: W-89 Min. 15/32-inch plywood, 24-inch span Glasbase Base Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet OMG #14 HD with OMG 3 in. Round Metal Plate or Trufast #12 DP or #14 HD with Trufast 3” Metal Insulation Plate 6-inch o.c. at 4-inch lap and 6- inch o.c. in three (3), equally spaced, staggered center rows FlintPrime QD at stress plates SBS-SA-H SBS-AA or APP-TA -97.5 W-90 Min. 19/32-inch plywood, 24-inch span Glasbase Base Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet Note 2 7-inch o.c. at 3-inch lap and 7- inch o.c. in three (3), equally spaced, staggered center rows None SBS-SA-H SBS-AA or APP-TA -105.0 W-91 Min. 15/32-inch plywood, 24-inch span Glasbase Base Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet OMG #14 HD with OMG 3 in. Round Metal Plate or Trufast #12 DP or #14 HD with Trufast 3” Metal Insulation Plate 6-inch o.c. at 4-inch lap and 6- inch o.c. in four (4), equally spaced, staggered center rows FlintPrime QD at stress plates SBS-SA-H SBS-AA or APP-TA -127.5 CONVENTIONAL SYSTEMS: W-92 Min. 23/32-inch plywood, 24-inch span Glasbase Base Sheet, All Weather/Empire Base Sheet, Flintlastic Base 20 or Flintglas MS Cap (inverted) Note 2 12-inch o.c. at 4-inch lap and 36- inch o.c. in two (2), equally spaced, staggered center rows None BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP-TA -30.0* W-93 Min. 23/32-inch plywood, 24-inch span Glasbase Base Sheet, All Weather/Empire Base Sheet, Flintlastic Base 20 or Flintglas MS Cap (inverted) Note 2 12-inch o.c. at 4-inch lap and 24- inch o.c. in two (2), equally spaced, staggered center rows None BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP-TA -45.0* W-94 Min. 23/32-inch plywood, 24-inch span Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet Note 2 12-inch o.c. at 4-inch lap and 36- inch o.c. in two (2), equally spaced, staggered center rows None BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP-TA -45.0* W-95 Min. 15/32-inch plywood, 24-inch span Glasbase Base Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet or Flintglas MS Cap (inverted) OMG #14 HD with OMG 3 in. Round Metal Plate or Trufast #12 DP or #14 HD with Trufast 3” Metal Insulation Plate 6-inch o.c. at 4-inch lap and 6- inch o.c. in three (3), equally spaced, staggered center rows None (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP-TA -97.5 W-96 Min. 15/32-inch plywood, 24-inch span Flintlastic APP Base T OMG #14 HD with OMG 3 in. Round Metal Plates 6-inch o.c. at 4-inch lap and 6- inch o.c. in three (3), equally spaced, staggered center rows. None APP-TA APP-TA -97.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R29 for FL2533-R28 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 29: 04/14/2022 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 18 of 70 TABLE 1G: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE E-2: NON-INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Base Sheet Primer Roof Cover (Note 15) MDP (psf) Base Fasteners Attach Base Ply Cap Ply W-97 Min. 15/32-inch plywood, 24-inch span Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet or Flintglas MS Cap (inverted) Trufast #14 HD with Trufast 3” Metal Insulation Plate 8-inch o.c. at 4-inch lap and 8- inch o.c. at three (3) equally spaced, staggered center rows None (Optional) BP-AA, SBS- AA or SBS-TA SBS-AA -97.5 W-98 Min. 19/32-inch plywood, 24-inch span Glasbase Base Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet or Flintglas MS Cap (inverted) Note 2 7-inch o.c. at 3-inch lap and 7- inch o.c. in three (3), equally spaced, staggered center rows None BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP-TA -105.0 W-99 Min. 19/32-inch plywood, 24-inch span Flintlastic APP Base T Dekfast DF-#14-PH3 with PLT-H-2-7/8 or OMG #14 HD with OMG 3 in. Round Metal Plate 7-inch o.c. at 3-inch lap and 7- inch o.c. in three (3), equally spaced, staggered center rows None APP-TA APP-TA -105.0 W-100 Min. 15/32-inch plywood, 24-inch span Glasbase Base Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet or Flintglas MS Cap (inverted) OMG #14 HD with OMG 3 in. Round Metal Plate or Trufast #12 DP or #14 HD with Trufast 3” Metal Insulation Plate 6-inch o.c. at 4-inch lap and 6- inch o.c. in four (4), equally spaced, staggered center rows None (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP-TA -127.5 W-101 Min. 15/32-inch plywood, 24-inch span Flintlastic APP Base T OMG #14 HD with OMG 3 in. Round Metal Plates 6-inch o.c. at 4-inch lap and 6- inch o.c. in four (4), equally spaced, staggered center rows. None APP-TA APP-TA -127.5 COLD-APPLIED SYSTEMS: W-102 Min. 15/32-inch plywood, 24-inch span Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet or Flintglas MS Cap (inverted) Trufast #12 DP or #14 HD with Trufast 3” Metal Insulation Plate 8-inch o.c. at 4-inch lap and 8- inch o.c. in three (3), equally spaced, staggered center rows None (Optional) SBS-CA1 SBS-CA1 -52.5 TABLE 1H: WOOD DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE F: NON-INSULATED, BONDED ROOF COVER System No. Deck (Note 1) Primer Roof Cover (Note 15) MDP (psf) Base Ply Ply Cap Ply W-103 APA rated, min. 7/16 CAT, 0.418 in., Exposure 1, OSB sheathing, 24-inch span FlintPrime QD Flintlastic SA Mid Ply, self-adhering (Optional) SBS-SA SBS-SA -90.0 W-104 Min. 15/32-inch plywood, 24-inch span FlintPrime QD SBS-SA-H (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -112.5 W-105 Min. 15/32-inch plywood, 24-inch span FlintPrime QD SBS-SA (Optional) SBS-SA SBS-SA -127.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R29 for FL2533-R28 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 29: 04/14/2022 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 19 of 70 TABLE 2A: STEEL OR STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE B-1: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Fasteners Attach Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply SELF-ADHERING SYSTEMS: S-1 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 2-inch ACFoam II, ENRGY 3 or H- Shield Note 2 1 per 4.0 ft2 Optional min. 1.5-inch additional layer(s) base insulation, followed by min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board hot asphalt, M- OSFA, Insta Stik, OB500, Polyset BM, Polyset CRA SBS-SA (Optional) SBS-SA SBS-SA -37.5* S-2 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 1.5-inch ACFoam II, ENRGY 3 or H- Shield Note 2 1 per 2.0 ft2 Optional min. 1.5-inch additional layer(s) base insulation, followed by min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board hot asphalt, M- OSFA, Insta Stik, OB500, Polyset BM, Polyset CRA SBS-SA (Optional) SBS-SA SBS-SA -45.0* HYBRID SYSTEMS: S-3 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 1.5-inch ACFoam II, ENRGY 3 or H- Shield Note 2 1 per 1.45 ft2 Additional layer(s) base insulation hot asphalt, M- OSFA, Insta Stik, OB500, Polyset BM, Polyset CRA Flintlastic Ultra Glass SA (Optional) SBS- AA, SBS-TA, APP- TA SBS-AA, APP-TA -37.5 S-4 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 1.5-inch ACFoam II, ENRGY 3 or H- Shield Note 2 1 per 1.45 ft2 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board hot asphalt, M- OSFA, Insta Stik, OB500, Polyset BM, Polyset CRA Flintlastic Ultra Glass SA (Optional) SBS- AA, SBS-TA, APP- TA SBS-AA, APP-TA -52.5 S-5 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 1.5-inch ACFoam II or H- Shield Trufast #12 DP or #14 HD with Trufast 3”Metal Insulation Plates 1 per 1.45 ft2 Min. 1.5-inch ACFoam II or H- Shield hot asphalt, M- OSFA, M-PG1, Insta Stik, OB500 SBS-SA-H (Optional) APP- TA APP-TA -67.5 S-6 Min. 22 ga., type B, Grade 40 steel or min. 2,500 psi structrual concrete Min. 1.5-inch ACFoam II or H- Shield Trufast #12 DP (steel only) or #14 HD with Trufast 3” Metal Insulation Plate 1 per 1.6 ft2 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board M-OSFA, M-PG1, Insta Stik, OB500 SBS-SA-H (Optional) SBS-TA or APP-TA APP-TA -75.0 S-7 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 1.5-inch ENRGY 3 Trufast #12 DP (steel only) or #14 HD with Trufast 3” Metal Insulation Plate 1 per 1.0 ft2 Min. 0.5-inch SECUROCK Gypsum-Fiber Roof Board OB500, 4-inch o.c. SBS-SA-H (Optional) SBS-TA or APP-TA APP-TA -90.0* CONVENTIONAL SYSTEMS: S-8 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 2-inch ACFoam II, ENRGY 3 or H- Shield Note 2 1 per 4.0 ft2 Optional min. 1.5-inch additional layer(s) base insulation, followed by min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board hot asphalt, M- OSFA, Insta Stik, OB500, Polyset BM, Polyset CRA BP-AA, SBS- AA, SBS-TA or APP-TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA or APP-TA -37.5* NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R29 for FL2533-R28 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 29: 04/14/2022 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 20 of 70 TABLE 2A: STEEL OR STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE B-1: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Fasteners Attach Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply S-9 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 1.5-inch ACFoam II, ENRGY 3 or H- Shield Note 2 1 per 2.0 ft2 Optional min. 1.5-inch additional layer(s) base insulation, followed by min. 0.5-inch Structodek High Density Fiberboard Roof Insulation, min. 0.75-inch FescoBoard (homogeneous). hot asphalt BP-AA or SBS-AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA or APP-TA -45.0* S-10 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 1.5-inch ACFoam II, ENRGY 3 or H- Shield Note 2 1 per 2.0 ft2 Optional min. 1.5-inch additional layer(s) base insulation, followed by min. 0.25-inch DensDeck or DensDeck Prime hot asphalt BP-AA, SBS- AA, SBS-TA or APP-TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA or APP-TA -45.0* S-11 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 1.5-inch ACFoam II, ENRGY 3 or H- Shield Note 2 1 per 2.0 ft2 Optional min. 1.5-inch additional layer(s) base insulation, followed by min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board hot asphalt, M- OSFA, Insta Stik, OB500, Polyset BM, Polyset CRA BP-AA, SBS- AA, SBS-TA or APP-TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA or APP-TA -45.0* S-12 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 2-inch ACFoam II, ENRGY 3 or H- Shield Note 2 1 per 3.2 ft2 Optional min. 1.5-inch additional layer(s) base insulation, followed by min. 0.5-inch Structodek High Density Fiberboard Roof Insulation, min. 0.75-inch FescoBoard (homogeneous). hot asphalt BP-AA or SBS-AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA or APP-TA -45.0* S-13 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 2-inch ACFoam II, ENRGY 3 or H- Shield Note 2 1 per 3.2 ft2 Optional min. 1.5-inch additional layer(s) base insulation, followed by min. 0.25-inch DensDeck or DensDeck Prime hot asphalt BP-AA, SBS- AA, SBS-TA or APP-TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA or APP-TA -45.0* S-14 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 1.5-inch ACFoam II, ENRGY 3 or Multi-Max FA3 Note 2 1 per 1.3 ft2 Min. 0.75-inch FescoBoard (homogeneous) hot asphalt BP-AA or SBS-AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA or APP-TA -52.5 S-15 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 2-inch ACFoam II, ENRGY 3 or H- Shield Note 2 1 per 1.6 ft2 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board hot asphalt, M- OSFA, Insta Stik, OB500, Polyset BM, Polyset CRA BP-AA, SBS- AA, SBS-TA or APP-TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA or APP-TA -60.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R29 for FL2533-R28 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 29: 04/14/2022 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 21 of 70 TABLE 2A: STEEL OR STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE B-1: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Fasteners Attach Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply S-16 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 1.5-inch ACFoam II, ENRGY 3 or Multi-Max FA3 Note 2 1 per 1.3 ft2 Min. 0.5-inch Structodek High Density Fiberboard hot asphalt BP-AA or SBS-AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA or APP-TA -67.5 S-17 Min. 22 ga., type B, Grade 40 steel or min. 2,500 psi structrual concrete Min. 1.5-inch ACFoam II or H- Shield Trufast #12 DP (steel only) or #14 HD with Trufast 3” Metal Insulation Plate 1 per 1.6 ft2 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board M-OSFA, M-PG1, Insta Stik, OB500 BP-AA, SBS- AA, SBS-TA or APP-TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA or APP-TA -75.0 S-18 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 1.5-inch ENRGY 3 Trufast #12 DP (steel only) or #14 HD with Trufast 3” Metal Insulation Plate 1 per 1.0 ft2 Min. 0.5-inch SECUROCK Gypsum-Fiber Roof Board OB500, 4-inch o.c. BP-AA, SBS- AA, SBS-TA or APP-TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA or APP-TA -90.0* COLD-APPLIED SYSTEMS: S-19 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 2-inch ACFoam II or H- Shield Trufast #12 DP (steel only) or #14 HD with Trufast 3” Metal Insulation Plate 1 per 2.0 ft2 Min. 1.5-inch ACFoam III or H-Shield CG OB500 or Polyset CRA SBS-CA1 None SBS-CA1 -45.0* S-20 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 2-inch ACFoam II or H- Shield Trufast #12 DP (steel only) or #14 HD with Trufast 3” Metal Insulation Plate 1 per 2.0 ft2 Optional min. 1.5-inch additional layer(s) base insulation, followed by min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Insta Stik, M-OSFA, M-PG1, OB500, Polyset BM or Polyset CRA SBS-CA1 None SBS-CA1 -45.0* S-21 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 2-inch ACFoam II or H- Shield Trufast #12 DP (steel only) or #14 HD with Trufast 3” Metal Insulation Plate 1 per 2.0 ft2 Optional min. 1.5-inch additional layer(s) base insulation, followed by min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Insta Stik, M-OSFA, M-PG1, OB500, Polyset BM or Polyset CRA SBS-CA4 None SBS-CA4 -45.0* S-22 Min. 22 ga., type B, Grade 40 steel or min. 2,500 psi structrual concrete Min. 1.5-inch ACFoam II or H- Shield Trufast #12 DP (steel only) or #14 HD with Trufast 3” Metal Insulation Plate 1 per 1.6 ft2 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board M-OSFA, M-PG1, Insta Stik, OB500 SBS-CA1 None SBS-CA1 -75.0 S-23 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 1.5-inch ENRGY 3 Trufast #12 DP (steel only) or #14 HD with Trufast 3” Metal Insulation Plate 1 per 1.0 ft2 Min. 0.5-inch SECUROCK Gypsum-Fiber Roof Board OB500, 4-inch o.c. SBS-CA1 None SBS-CA1 -90.0* NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R29 for FL2533-R28 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 29: 04/14/2022 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 22 of 70 TABLE 2B: STEEL OR STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer(s) (Note 13) Top Insulation Layer Primer Roof Cover (Note 15) MDP (psf) Type Fasteners Attach Base Ply Ply Cap Ply SELF-ADHERING SYSTEMS: S-24 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Note 2 1 per 3.2 ft2 None SBS-SA (Optional) SBS- SA SBS-SA -30.0* S-25 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Trufast #12 DP (steel only) or #14 HD with Trufast 3” Metal Insulation Plate 1 per 2.7 ft2 None SBS-SA (Optional) SBS- SA SBS-SA -37.5* S-26 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 3/8-inch SECUROCK Gypsum-Fiber Roof Board Note 2 1 per 2.7 ft2 None SBS-SA (Optional) SBS- SA SBS-SA -45.0* S-27 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 0.25-inch DensDeck Note 2 1 per 1.3 ft2 FlintPrime QD SBS-SA (Optional) SBS- SA SBS-SA -45.0 S-28 Min. 22 ga., type B, Grade 40 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 1.5-inch ACFoam II Trufast #14 HD with Trufast 3” Metal Insulation Plate 1 per 1.8 ft2 FlintPrime QD SBS-SA (Optional) SBS- SA SBS-SA -67.5 S-29 Min. 22 ga., type B, Grade 40 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 0.5-inch SECUROCK Gypsum-Fiber Roof Board Trufast #14 HD with Trufast 3” Metal Insulation Plate 1 per 1.6 ft2 FlintPrime QD SBS-SA (Optional) SBS- SA SBS-SA -82.5 S-30 Min. 22 ga., type B, Grade 40 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 1.5-inch ACFoam II or H-Shield Trufast #15 EHD (steel only) or Trufast #14 HD (concrete only) with Trufast 3” Metal Insulation Plate 1 per 1.0 ft2 FlintPrime QD SBS-SA (Optional) SBS- SA SBS-SA -97.5 HYBRID SYSTEMS: S-31 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 0.25-inch DensDeck, DensDeck Prime Note 2 1 per 2.0 ft2 None SBS-SA- H (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -30.0* S-32 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Trufast #12 DP (steel only) or #14 HD with Trufast 3” Metal Insulation Plate 1 per 2.7 ft2 None SBS-SA- H (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -37.5* S-33 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 3/8-inch SECUROCK Gypsum-Fiber Roof Board Trufast #12 DP (steel only) or #14 HD with Trufast 3” Metal Insulation Plate 1 per 2.7 ft2 None SBS-SA- H (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -45.0* S-34 Min. 22 ga., type B, Grade 40 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 1.5-inch ACFoam II Trufast #14 HD with Trufast 3” Metal Insulation Plate 1 per 1.8 ft2 None SBS-SA- H (Optional) SBS- TA or APP-TA APP-TA -67.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R29 for FL2533-R28 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 29: 04/14/2022 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 23 of 70 TABLE 2B: STEEL OR STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer(s) (Note 13) Top Insulation Layer Primer Roof Cover (Note 15) MDP (psf) Type Fasteners Attach Base Ply Ply Cap Ply S-35 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 1.5-inch ACFoam II or H-Shield Trufast #12 DP (steel only) or Trufast #14 HD with Trufast 3” Metal Insulation Plate 1 per 1.45 ft2 None SBS-SA- H (Optional) SBS- AA, SBS-TA or APP-TA SBS-AA or APP-TA -75.0 S-36 Min. 22 ga., type B, Grade 40 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 0.5-inch SECUROCK Gypsum-Fiber Roof Board Trufast #14 HD with Trufast 3” Metal Insulation Plate 1 per 1.6 ft2 None SBS-SA- H (Optional) SBS- TA or APP-TA APP-TA -82.5 S-37 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 0.5-inch SECUROCK Gypsum-Fiber Roof Board Trufast #12 DP (steel only) or #14 HD with Trufast 3” Metal Insulation Plate 1 per 1.45 ft2 None SBS-SA- H (Optional) SBS- TA or APP-TA APP-TA -82.5 S-38 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 1.5-inch ACFoam II, ENRGY 3 or Multi-Max FA3 Note 2 1 per 1.3 ft2 None SBS-SA- H (Optional) SBS- AA, SBS-TA or APP-TA SBS-AA or APP-TA -82.5 S-39 Min. 22 ga., type B, Grade 40 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 1.5-inch ACFoam II or H-Shield Trufast #15 EHD (steel only) or Trufast #14 HD (concrete only) with Trufast 3” Metal Insulation Plate 1 per 1.0 ft2 None SBS-SA- H (Optional) SBS- AA, SBS-TA or APP-TA SBS-AA or APP-TA -97.5 S-40 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 0.5-inch SECUROCK Gypsum-Fiber Roof Board Trufast #12 DP (steel only) or #14 HD with Trufast 3” Metal Insulation Plate 1 per 1.0 ft2 None SBS-SA- H (Optional) SBS- TA or APP-TA APP-TA -135.0 CONVENTIONAL SYSTEMS: S-41 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 0.75-inch FescoBoard (homogeneous) Note 2 1 per 2.7 ft2 None BP-AA, SBS-AA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -30.0* S-42 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation Note 2 1 per 4.0 ft2 None BP-AA, SBS-AA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -37.5* S-43 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Note 2 1 per 4.0 ft2 None BP-AA, SBS-AA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -37.5* S-44 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Note 2 1 per 4.0 ft2 None BP-AA, SBS-AA, SBS-TA or APP- TA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -45.0* NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R29 for FL2533-R28 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 29: 04/14/2022 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 24 of 70 TABLE 2B: STEEL OR STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer(s) (Note 13) Top Insulation Layer Primer Roof Cover (Note 15) MDP (psf) Type Fasteners Attach Base Ply Ply Cap Ply S-45 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation, min. 0.75- inch FescoBoard (homogeneous) Note 2 1 per 2.0 ft2 None BP-AA or SBS-AA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -45.0* S-46 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 0.25-inch DensDeck or DensDeck Prime Note 2 1 per 2.0 ft2 None BP-AA, SBS-AA, SBS-TA or APP- TA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -45.0* S-47 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 1.5-inch, One or more layers, any combination, loose laid Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Trufast #12 DP (steel only) or Trufast #14 HD with Trufast 3” Metal Insulation Plate 1 per 1.45 ft2 None APP-TA (Optional) APP- TA APP-TA -60.0 S-48 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 2-inch ACFoam II, ENRGY 3 or H-Shield, loose laid. Min. 0.5-inch SECUROCK Gypsum-Fiber Roof Board Note 2 1 per 1.8 ft2 None BP-AA, SBS-AA, SBS-TA or APP- TA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -60.0 S-49 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 0.5-inch SECUROCK Gypsum-Fiber Roof Board Trufast #12 DP (steel only) or #14 HD with Trufast 3” Metal Insulation Plate 1 per 1.45 ft2 None BP-AA, SBS-AA, SBS-TA or APP- TA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -82.5 S-50 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 1.5-inch ACFoam II or H-Shield Min. 0.5-inch DensDeck Prime Trufast #14 HD with Trufast 3” Metal Insulation Plate 1 per 1.3 ft2 None BP-AA, SBS-AA (Optional) BP- AA, SBS-AA SBS-AA -112.5 S-51 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 0.5-inch SECUROCK Gypsum-Fiber Roof Board Trufast #12 DP (steel only) or #14 HD with Trufast 3” Metal Insulation Plate 1 per 1.0 ft2 None BP-AA, SBS-AA, SBS-TA or APP- TA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -135.0 S-52 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 1.5-inch ACFoam II or H-Shield Min. 0.5-inch SECUROCK Gypsum-Fiber Roof Board Trufast #14 HD with Trufast 3” Metal Insulation Plate 1 per 1.3 ft2 None BP-AA, SBS-AA (Optional) BP- AA, SBS-AA SBS-AA -157.5 S-53 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 1.5-inch ACFoam II or H-Shield Min. 0.5-inch DensDeck Prime Trufast #14 HD with Trufast 3” Metal Insulation Plate 1 per 1.0 ft2 None BP-AA, SBS-AA (Optional) BP- AA, SBS-AA SBS-AA -157.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R29 for FL2533-R28 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 29: 04/14/2022 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 25 of 70 TABLE 2B: STEEL OR STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer(s) (Note 13) Top Insulation Layer Primer Roof Cover (Note 15) MDP (psf) Type Fasteners Attach Base Ply Ply Cap Ply S-54 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 1.5-inch ACFoam II or H-Shield Min. 0.5-inch SECUROCK Gypsum-Fiber Roof Board Trufast #14 HD with Trufast 3” Metal Insulation Plate 1 per 1.0 ft2 None BP-AA, SBS-AA (Optional) BP- AA, SBS-AA SBS-AA -172.5 SPOT- OR STRIP-MOPPED SYSTEMS: S-55 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 2-inch ACFoam II or ENRGY 3 Note 2 1 per 1.6 ft2 None BP-AA2 (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -37.5* S-56 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 1-inch FescoBoard (homogeneous) or min. 1.5- inch FescoBoard (laminated) Note 2 1 per 1.6 ft2 None BP-AA2 (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -45.0* S-57 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 0.5-inch Structodek HD with Primed Red Coating Note 2 1 per 2.0 ft2 None BP-AA2 (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -45.0* S-58 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 1.5-inch ACFoam II Note 2 1 per 1.45 ft2 None BP-AA3, 24-inch grid (Optional) BP-AA or SBS-AA SBS-AA -52.5 S-59 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 1.5-inch ACFoam II Note 2 1 per 1.45 ft2 None BP-AA3, 24-inch grid BP-AA or SBS-AA SBS-TA -52.5 COLD-APPLIED SYSTEMS: S-60 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Trufast #12 DP (steel only) or #14 HD with Trufast 3” Metal Insulation Plate 1 per 2.7 ft2 None SBS-CA1 None SBS-CA1 -37.5* S-61 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Trufast #12 DP (steel only) or #14 HD with Trufast 3” Metal Insulation Plate 1 per 2.7 ft2 None SBS-CA4 None SBS-CA4 -37.5* S-62 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 1.5-inch ACFoam III or H-Shield CG Trufast #12 DP (steel only) or #14 HD with Trufast 3” Metal Insulation Plate 1 per 2.0 ft2 None SBS-CA1 None SBS-CA1 -45.0* S-63 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 3/8-inch SECUROCK Gypsum-Fiber Roof Board Trufast #12 DP (steel only) or #14 HD with Trufast 3” Metal Insulation Plate 1 per 2.7 ft2 None SBS-CA1 None SBS-CA1 -45.0* S-64 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 3/8-inch SECUROCK Gypsum-Fiber Roof Board Trufast #12 DP (steel only) or #14 HD with Trufast 3” Metal Insulation Plate 1 per 2.7 ft2 None SBS-CA4 None SBS-CA4 -45.0* S-65 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 0.5-inch SECUROCK Gypsum-Fiber Roof Board Trufast #12 DP (steel only) or #14 HD with Trufast 3” Metal Insulation Plate 1 per 1.45 ft2 None SBS-CA1 None SBS-CA1 -82.5* NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R29 for FL2533-R28 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 29: 04/14/2022 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 26 of 70 TABLE 2C: STEEL OR STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE D-2: INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Insulation Layer(s) (Note 13) Base Sheet Roof Cover (Note 15) MDP (psf) Type Attach Type Fasteners Attach Base Ply Cap Ply SELF-ADHERING SYSTEMS: S-66 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 1.5-inch, One or more layers, any combination Prelim. Attached Flintlastic SA NailBase Note 2 9-inch o.c. at min. 2-inch lap and 18-inch o.c. in two (2), equally spaced, staggered center rows (Optional) SBS- SA SBS-SA -45.0* S-67 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 1.5-inch, One or more layers, any combination Prelim. Attached Flintlastic SA NailBase Note 2 12-inch o.c. at min. 2-inch lap and 12-inch o.c. in two (2), equally spaced, staggered center rows (Optional) SBS- SA SBS-SA -52.5* S-68 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 1.5-inch, One or more layers, any combination Prelim. Attached Flintlastic SA NailBase Note 2 12-inch o.c. at min. 4-inch lap and 12-inch o.c. in two (2), equally spaced, staggered center rows (Optional) SBS- SA SBS-SA -60.0* S-69 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 1.5-inch, One or more layers, any combination Prelim. Attached Flintlastic SA NailBase (laid parallel to deck flutes) Note 2 8-inch o.c. at min. 4-inch lap and 8- inch o.c. in two (2), equally spaced, staggered center rows, FlintPrime QD at stress plates (Optional) SBS- SA SBS-SA -82.5* CONVENTIONAL SYSTEMS: S-70 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 1.5-inch, One or more layers, any combination Prelim. Attached Glasbase Base Sheet, All Weather/Empire Base Sheet, Flintlastic Base 20 or Flintglas MS Cap (inverted) Note 2 12-inch o.c. at 4-inch lap and 36- inch o.c. in two (2), equally spaced, staggered center rows BP-AA, SBS-AA, SBS-TA or APP- TA SBS-AA or APP-TA -30.0* S-71 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 1.5-inch, One or more layers, any combination Prelim. Attached Glasbase Base Sheet, All Weather/Empire Base Sheet, Flintlastic Base 20 or Flintglas MS Cap (inverted) Note 2 12-inch o.c. at 4-inch lap and 24- inch o.c. in two (2), equally spaced, staggered center rows BP-AA, SBS-AA, SBS-TA or APP- TA SBS-AA or APP-TA -45.0* S-72 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 1.5-inch, One or more layers, any combination Prelim. Attached Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet Note 2 12-inch o.c. at 4-inch lap and 36- inch o.c. in two (2), equally spaced, staggered center rows BP-AA, SBS-AA, SBS-TA or APP- TA SBS-AA or APP-TA -45.0* S-73 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 1.5-inch, One or more layers, any combination Prelim. Attached Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet Note 2 18-inch o.c. at 4-inch lap and 18- inch o.c. in one (1) staggered center row BP-AA, SBS-AA, SBS-TA or APP- TA SBS-AA or APP-TA -45.0* S-74 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 1.5-inch, One or more layers, any combination Prelim. Attached Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet Dekfast DF-#14-PH3 with PLT-R-2-4B 12-inch o.c. within the min. 4-inch wide, heat-welded side lap SBS-AA, SBS-TA or APP-TA SBS-AA or APP-TA -45.0* S-75 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 1.5-inch, One or more layers, any combination Prelim. Attached Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet, Flintlastic Poly SMS Base Sheet or Flintglas MS Cap (inverted) Note 2 12-inch o.c. at 3-inch lap and 12- inch o.c. in two (2), equally spaced, staggered center rows BP-AA, SBS-AA, SBS-TA or APP- TA SBS-AA or APP-TA -52.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R29 for FL2533-R28 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 29: 04/14/2022 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 27 of 70 TABLE 2C: STEEL OR STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE D-2: INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Insulation Layer(s) (Note 13) Base Sheet Roof Cover (Note 15) MDP (psf) Type Attach Type Fasteners Attach Base Ply Cap Ply S-76 Min. 22 ga., type B, 40 ksi steel or min. 2,500 psi structrual concrete Min. 2-inch, One or more layers, any combination Prelim. Attached Flintlastic Ultra Poly SMS Base Sheet Trufast #15 EHD (steel only) or Trufast #14 HD (concrete only) with Trufast 2” Barbed Metal Seam Plate 12-inch o.c. within the min. 4-inch wide, heat-welded side lap (Optional) SBS- TA or APP-TA APP-TA -52.5 S-77 Min. 22 ga., type B, Grade 80 steel or min. 2,500 psi structrual concrete Min. 1.5-inch, One or more layers, any combination Prelim. Attached Flintlastic Ultra Poly SMS Base Sheet Trufast #15 EHD (steel only) or Trufast #14 HD (concrete only) with Trufast 2.4” Barbed Metal Seam Plate 12-inch o.c. within the min. 4-inch wide, heat-welded side lap (Optional) SBS- TA or APP-TA APP-TA -60.0 S-78 Min. 22 ga., type B, 40 ksi steel or min. 2,500 psi structrual concrete Min. 2-inch, One or more layers, any combination Prelim. Attached Flintlastic Ultra Poly SMS Base Sheet Trufast #15 EHD (steel only) or Trufast #14 HD (concrete only) with Trufast 2.4” Scoop Seam Plate 12-inch o.c. within the min. 4-inch wide, heat-welded side lap (Optional) SBS- TA or APP-TA APP-TA -67.5 S-79 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 1.5-inch, One or more layers, any combination Prelim. Attached Glasbase Base Sheet or Flintglas MS Cap (inverted) OMG #14 HD with OMG Flat Bottom Plates (AccuTrac) 6-inch o.c. at 4-inch lap and 6-inch o.c. in two (2), equally spaced, staggered center rows BP-AA, SBS-AA, SBS-TA or APP- TA SBS-AA or APP-TA -67.5 S-80 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 1.5-inch, One or more layers, any combination Prelim. Attached Flintlastic Base 20 or Flintglas MS Cap (inverted) Note 2 6-inch o.c. at 4-inch lap and 6-inch o.c. in two (2), equally spaced, staggered center rows BP-AA, SBS-AA, SBS-TA or APP- TA SBS-AA or APP-TA -67.5 S-81 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 1.5-inch, One or more layers, any combination Prelim. Attach Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet or Flintglas MS Cap (inverted) Trufast #14 HD with Trufast 3” Metal Insulation Plate 6-inch o.c. at 4-inch lap and 6-inch o.c. at three (3) equally spaced, staggered center rows (Optional) BP- AA, SBS-AA or SBS-TA SBS-AA -97.5 S-82 Min. 22 ga., type B, 40 ksi steel or min. 2,500 psi structrual concrete Min. 2-inch, One or more layers, any combination Prelim. Attached Flintlastic Ultra Poly SMS Base Sheet Trufast #15 EHD (steel only) or Trufast #14 HD (concrete only) with Trufast 2.4” Scoop Seam Plate 6-inch o.c. within the min. 4-inch wide, heat-welded side lap (Optional) SBS- TA or APP-TA APP-TA -112.5 S-83 Min. 22 ga., type B, Grade 80 steel or min. 2,500 psi structrual concrete Min. 1.5-inch, One or more layers, any combination Prelim. Attached Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet Note 2 12-inch o.c. at 4-inch lap and 12- inch o.c. in two (2), equally spaced, staggered center rows SBS-TA or APP- TA APP-TA -112.5 S-84 Min. 22 ga., type B, Grade 80 steel or min. 2,500 psi structrual concrete Min. 1.5-inch, One or more layers, any combination Prelim. Attached Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet Note 2 12-inch o.c. at 4-inch lap and 12- inch o.c. in two (2), equally spaced, staggered center rows SBS-AA SBS-AA -120.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R29 for FL2533-R28 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 29: 04/14/2022 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 28 of 70 TABLE 2C: STEEL OR STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE D-2: INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Insulation Layer(s) (Note 13) Base Sheet Roof Cover (Note 15) MDP (psf) Type Attach Type Fasteners Attach Base Ply Cap Ply S-85 Min. 22 ga., type B, 40 ksi steel or min. 2,500 psi structrual concrete Min. 2-inch, One or more layers, any combination Prelim. Attached Flintlastic Ultra Poly SMS Base Sheet Trufast #15 EHD (steel only) or Trufast #14 HD (concrete only) with Trufast 2.4” Scoop Seam Plate 6-inch o.c. within the min. 4-inch wide, heat-welded side laps and 6- inch o.c. in one (1) center row, stripped-in with 6-inch side strips of torch-applied Flintlastic Poly SMS Base Sheet or Flintlastic Ultra Poly SMS Base Sheet. (Optional) SBS- TA or APP-TA APP-TA -165.0 COLD-APPLIED SYSTEMS: S-86 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 1.5-inch, One or more layers, any combination Prelim. Attached Glasbase Base Sheet, All Weather/Empire Base Sheet, Flintlastic Base 20 Note 2 6-inch o.c. at 4-inch lap and 12- inch o.c. in two (2), equally spaced, staggered center rows SBS-CA1 SBS-CA1 -45.0* S-87 Min. 22 ga., type B, Grade 40 steel or min. 2,500 psi structrual concrete Min. 1-inch, One or more layers, any combination Loose-laid Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet Trufast #14 HD with Trufast 3” Metal Insulation Plate 6-inch o.c. at 4-inch lap and 12- inch o.c. in three (3), equally spaced, staggered center rows (Optional) SBS- CA1 SBS-CA1 -75.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R29 for FL2533-R28 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 29: 04/14/2022 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 29 of 70 TABLE 3A: STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER SEE NOTE 16 FOR VAPOR BARRIER OPTIONS Sys. No. Deck (Note 1) Primer Base Insulation Layer Top Insulation Layer Primer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply SELF-ADHERING SYSTEMS: C-1. Structural concrete FlintPrime QD Min. 1.5-inch ACFoam II, ENRGY 3 or H-Shield hot asphalt Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board hot asphalt None SBS-SA (Optional) SBS- SA SBS-SA -172.5 C-2. Structural concrete FlintPrime QD Min. 1.5-inch ACFoam II, ENRGY 3 or Multi-Max FA3 hot asphalt Min. 0.25-inch DensDeck hot asphalt FlintPrime QD SBS-SA (Optional) SBS- SA SBS-SA -192.5 C-3. Structural concrete None (Optional) Min. 1.5-inch ACFoam II or H-Shield M-OSFA or M- PG1 Min. 0.5-inch ACFoam-HD CoverBoard or H-Shield HD M-OSFA or M- PG1 FlintPrime QD SBS-SA (Optional) SBS- SA SBS-SA -97.5 C-4. Structural concrete None (Optional) Min. 1.5-inch ACFoam II or H-Shield M-OSFA or M- PG1 Min. 2-inch H-Shield HD Composite CG M-OSFA or M- PG1 None SBS-SA (Optional) SBS- SA SBS-SA -142.5 C-5. Structural concrete None Min. 1.5-inch ACFoam II, ENRGY 3 or H-Shield M-OSFA or M- PG1 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board M-OSFA or M- PG1 None SBS-SA (Optional) SBS- SA SBS-SA -172.5 C-6. Structural concrete None Min. 1.5-inch ACFoam II, ENRGY 3 or Multi-Max FA3 M-OSFA or M- PG1 Min. 0.25-inch DensDeck M-OSFA or M- PG1 FlintPrime QD SBS-SA (Optional) SBS- SA SBS-SA -192.5 C-7. Structural concrete None (Optional) Min. 1.5-inch ACFoam II or H-Shield M-OSFA or M- PG1, 6-inch o.c. Min. 2-inch H-Shield HD Composite CG M-OSFA or M- PG1, 6-inch o.c. None SBS-SA (Optional) SBS- SA SBS-SA -305.0 C-8. Structural concrete None (Optional) Min. 1.5-inch ACFoam II or H-Shield M-OSFA or M- PG1, 6-inch o.c. Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board M-OSFA or M- PG1, 6-inch o.c. FlintPrime QD SBS-SA (Optional) SBS- SA SBS-SA -315.0 C-9. Structural concrete None (Optional) Min. 1.5-inch ACFoam II or H-Shield M-OSFA or M- PG1, 6-inch o.c. Min. 0.5-inch ACFoam-HD CoverBoard or H-Shield HD M-OSFA or M- PG1, 6-inch o.c. FlintPrime QD SBS-SA (Optional) SBS- SA SBS-SA -315.0 C-10. Structural concrete (Optional) FlintPrime QD Min. 1.5-inch Multi-Max FA Insta Stik Min. 0.25-inch DensDeck Insta Stik FlintPrime QD SBS-SA (Optional) SBS- SA SBS-SA -67.5 C-11. Structural concrete (Optional) FlintPrime QD Min. 1.5-inch ENRGY 3 Insta Stik Min. 0.25-inch DensDeck Insta Stik FlintPrime QD SBS-SA (Optional) SBS- SA SBS-SA -112.5 C-12. Structural concrete (Optional) FlintPrime QD Min. 1.5-inch ACFoam II Insta Stik Min. 0.25-inch DensDeck Insta Stik FlintPrime QD SBS-SA (Optional) SBS- SA SBS-SA -120.0 C-13. Structural concrete None Min. 1.5-inch ACFoam II, ENRGY 3 or H-Shield Insta Stik Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Insta Stik None SBS-SA (Optional) SBS- SA SBS-SA -172.5 C-14. Structural concrete FlintPrime QD Min. 1.5-inch ACFoam II or ENRGY 3 OB500 Min. 0.25-inch DensDeck OB500 FlintPrime QD SBS-SA (Optional) SBS- SA SBS-SA -120.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R29 for FL2533-R28 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 29: 04/14/2022 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 30 of 70 TABLE 3A: STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER SEE NOTE 16 FOR VAPOR BARRIER OPTIONS Sys. No. Deck (Note 1) Primer Base Insulation Layer Top Insulation Layer Primer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply C-15. Structural concrete None Min. 1.5-inch ACFoam II or ENRGY 3 OB500 Min. 0.25-inch DensDeck OB500 FlintPrime QD SBS-SA (Optional) SBS- SA SBS-SA -150.0 C-16. Structural concrete None Min. 1.5-inch ACFoam II, ENRGY 3 or H-Shield OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 None SBS-SA (Optional) SBS- SA SBS-SA -172.5 C-17. Structural concrete None Min. 1-inch ENRGY 3, H-Shield or H-Shield CG or min. 1.5-inch Multi- Max FA3 or Ultra-Max Polyset BM or Polyset CRA Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Polyset BM or Polyset CRA None SBS-SA (Optional) SBS- SA SBS-SA -172.5 C-18. Structural concrete None Min. 1-inch ENRGY 3, H-Shield or H-Shield CG or min. 1.5-inch Multi- Max FA3 or Ultra-Max Polyset BM or Polyset CRA Min. 0.25-inch DensDeck Polyset BM or Polyset CRA FlintPrime QD SBS-SA (Optional) SBS- SA SBS-SA -192.5 HYBRID SYSTEMS: C-19. Structural concrete FlintPrime QD Min. 1.5-inch ACFoam II or H- Shield hot asphalt (Optional) Additional layer(s) base insulation hot asphalt None Flintlastic Ultra Glass SA (Optional) SBS- AA, SBS-TA, APP- TA SBS-AA, APP-TA -322.5 C-20. Structural concrete FlintPrime QD Min. 1.5-inch ACFoam II or H- Shield hot asphalt (Optional) Additional layer(s) base insulation hot asphalt None Black Diamond Base Sheet (Optional) SBS- AA, SBS-TA, APP- TA SBS-AA, APP-TA -375.0 C-21. Structural concrete None (Optional) Min. 1.5-inch ACFoam II or H-Shield M-OSFA or M- PG1 Min. 0.5-inch ACFoam-HD CoverBoard or H-Shield HD M-OSFA or M- PG1 None SBS-SA-H (Optional) SBS- AA, SBS-TA, APP- TA SBS-AA, APP-TA -97.5 C-22. Structural concrete None Min. 1.5-inch ACFoam II or H- Shield M-OSFA (Optional) Additional layer(s) base insulation M-OSFA None SBS-SA-H (Optional) SBS- AA, SBS-TA, APP- TA SBS-AA, APP-TA -232.5 C-23. Structural concrete None Min. 1.5-inch ACFoam II or H- Shield M-OSFA Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board M-OSFA None SBS-SA-H (Optional) SBS- AA, SBS-TA, APP- TA SBS-AA, APP-TA -217.5 C-24. Structural concrete None Min. 1-inch Styrofoam Brand Roofmate M-OSFA or M- PG1 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board M-OSFA or M- PG1 None SBS-SA-H (Optional) SBS- AA, SBS-TA, APP- TA SBS-AA, APP-TA -210.0 C-25. Structural concrete None Min. 0.25-inch SECUROCK Gypsum- Fiber Roof Board M-OSFA None N/A None SBS-SA-H (Optional) SBS- AA, SBS-TA, APP- TA SBS-AA, APP-TA -195.0 C-26. Structural concrete None Min. 1.5-inch ACFoam II or H- Shield M-PG1 (Optional) Additional layer(s) base insulation M-PG1 None SBS-SA-H (Optional) SBS- AA, SBS-TA, APP- TA SBS-AA, APP-TA -270.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R29 for FL2533-R28 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 29: 04/14/2022 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 31 of 70 TABLE 3A: STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER SEE NOTE 16 FOR VAPOR BARRIER OPTIONS Sys. No. Deck (Note 1) Primer Base Insulation Layer Top Insulation Layer Primer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply C-27. Structural concrete None Min. 1.5-inch ACFoam II or H- Shield M-PG1 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board M-PG1 None SBS-SA-H (Optional) SBS- AA, SBS-TA, APP- TA SBS-AA, APP-TA -217.5 C-28. Structural concrete None Min. 0.25-inch SECUROCK Gypsum- Fiber Roof Board M-PG1 None N/A None SBS-SA-H (Optional) SBS- AA, SBS-TA, APP- TA SBS-AA, APP-TA -195.0 C-29. Structural concrete None (Optional) Min. 1.5-inch ACFoam II or H-Shield M-OSFA or M- PG1, 6-inch o.c. Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board or min. 0.5-inch ACFoam- HD CoverBoard or H-Shield HD M-OSFA or M- PG1, 6-inch o.c. None SBS-SA-H (Optional) SBS- AA, SBS-TA, APP- TA SBS-AA, APP-TA -315.0 C-30. Structural concrete None Min. 1.5-inch ACFoam II or H- Shield Insta Stik (Optional) Additional layer(s) base insulation Insta Stik None SBS-SA-H (Optional) SBS- AA, SBS-TA, APP- TA SBS-AA, APP-TA -135.0 C-31. Structural concrete None Min. 1.5-inch ACFoam II or H- Shield Insta Stik Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Insta Stik None SBS-SA-H (Optional) SBS- AA, SBS-TA, APP- TA SBS-AA, APP-TA -217.5 C-32. Structural concrete None Min. 0.25-inch SECUROCK Gypsum- Fiber Roof Board Insta Stik None N/A None SBS-SA-H (Optional) SBS- AA, SBS-TA, APP- TA SBS-AA, APP-TA -195.0 C-33. Structural concrete None Min. 1.5-inch ACFoam II or H- Shield OB500 (Optional) Additional layer(s) base insulation OB500 None SBS-SA-H (Optional) SBS- AA, SBS-TA, APP- TA SBS-AA, APP-TA -135.0 C-34. Structural concrete None Min. 1.5-inch ACFoam II or H- Shield OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 None SBS-SA-H (Optional) SBS- AA, SBS-TA, APP- TA SBS-AA, APP-TA -217.5 C-35. Structural concrete None Min. 0.25-inch SECUROCK Gypsum- Fiber Roof Board OB500 None N/A None SBS-SA-H (Optional) SBS- AA, SBS-TA, APP- TA SBS-AA, APP-TA -195.0 C-36. Structural concrete None Min. 1.5-inch ACFoam II or H- Shield Polyset BM or Polyset CRA (Optional) Additional layer(s) base insulation Polyset BM or Polyset CRA None SBS-SA-H (Optional) SBS- AA, SBS-TA, APP- TA SBS-AA, APP-TA -270.0 C-37. Structural concrete None Min. 1.5-inch ACFoam II or H- Shield Polyset BM or Polyset CRA Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Polyset BM or Polyset CRA None SBS-SA-H (Optional) SBS- AA, SBS-TA, APP- TA SBS-AA, APP-TA -217.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R29 for FL2533-R28 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 29: 04/14/2022 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 32 of 70 TABLE 3A: STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER SEE NOTE 16 FOR VAPOR BARRIER OPTIONS Sys. No. Deck (Note 1) Primer Base Insulation Layer Top Insulation Layer Primer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply C-38. Structural concrete None Min. 1.5-inch, min. 1.5 pcf Insulfoam II Roofing EPS Polyset CRA Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Polyset CRA None SBS-SA-H (Optional) SBS- AA, SBS-TA, APP- TA SBS-AA, APP-TA -180.0 C-39. Structural concrete None Min. 1.5-inch, min. 2.0 pcf Insulfoam IX Roofing EPS Polyset CRA Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Polyset CRA None SBS-SA-H (Optional) SBS- AA, SBS-TA, APP- TA SBS-AA, APP-TA -217.5 C-40. Structural concrete None Min. 1.5-inch Styrofoam Brand Roofmate Polyset CRA Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Polyset CRA None SBS-SA-H (Optional) SBS- AA, SBS-TA, APP- TA SBS-AA, APP-TA -217.5 C-41. Structural concrete None Min. 0.25-inch SECUROCK Gypsum- Fiber Roof Board Polyset BM or Polyset CRA None N/A None SBS-SA-H (Optional) SBS- AA, SBS-TA, APP- TA SBS-AA, APP-TA -195.0 CONVENTIONAL SYSTEMS: C-42. Structural concrete FlintPrime QD Min. 1.5-inch ACFoam II hot asphalt Min. 0.25-inch DensDeck, DensDeck Prime hot asphalt None SBS-TA (Optional) SBS- TA SBS-TA -180.0 C-43. Structural concrete FlintPrime QD (Optional) Min. 1.5-inch ACFoam II hot asphalt Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board hot asphalt None BP-AA, SBS-AA, SBS-TA or APP- TA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -180.0 C-44. Structural concrete FlintPrime QD (Optional) Min. 2-inch ACFoam II, ENRGY 3 or H-Shield hot asphalt Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board hot asphalt None BP-AA or SBS- AA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -225.0 C-45. Structural concrete FlintPrime QD (Optional) Min. 1.5-inch ACFoam II or H-Shield hot asphalt Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board hot asphalt None APP-TA (Optional) APP- TA APP-TA -252.5 C-46. Structural concrete FlintPrime QD Min. 1.5-inch ACFoam II, ENRGY 3 or H-Shield hot asphalt Min. 0.5-inch Structodek High Density Fiberboard hot asphalt None BP-AA or SBS- AA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -227.0 C-47. Structural concrete FlintPrime QD (Optional) Min. 2-inch ACFoam II, ENRGY 3 or H-Shield hot asphalt Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board hot asphalt None SBS-TA or APP- TA (Optional) SBS- TA or APP-TA APP-TA -232.5 C-48. Structural concrete FlintPrime QD Min. 1.5-inch ACFoam II, ENRGY 3 or H-Shield hot asphalt Min. 0.25-inch DensDeck hot asphalt None BP-AA or SBS- AA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -240.0 C-49. Structural concrete FlintPrime QD Min. 1.5-inch ACFoam II hot asphalt Min. 0.75-inch FescoBoard (homogeneous) hot asphalt None BP-AA or SBS- AA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -412.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R29 for FL2533-R28 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 29: 04/14/2022 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 33 of 70 TABLE 3A: STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER SEE NOTE 16 FOR VAPOR BARRIER OPTIONS Sys. No. Deck (Note 1) Primer Base Insulation Layer Top Insulation Layer Primer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply C-50. Structural concrete FlintPrime QD Min. 1.5-inch ACFoam II hot asphalt Min. 0.5-inch DuraBoard (homogeneous) hot asphalt None BP-AA or SBS- AA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -430.0 C-51. Structural concrete FlintPrime QD 0.5-inch Structodek High Density Fiberboard or min. 0.75-inch Fesco Board (homogeneous) hot asphalt None N/A None BP-AA (Optional) BP-AA or SBS-AA SBS-AA -437.5 C-52. Structural concrete FlintPrime QD 0.25-inch DensDeck, DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board hot asphalt None N/A None SBS-TA (Optional) SBS- AA or SBS-TA SBS-AA -302.5 C-53. Structural concrete FlintPrime QD 0.25-inch DensDeck, DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board hot asphalt None N/A None BP-AA (Optional) BP-AA or SBS-AA SBS-AA -537.5 C-54. Structural concrete None Min. 1.5-inch ACFoam II, ENRGY 3 or H-Shield M-OSFA Min. 0.5-inch Structodek High Density Fiberboard M-OSFA None BP-AA or SBS- AA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -127.5 C-55. Structural concrete None Min. 1.5-inch ACFoam II, ENRGY 3 or H-Shield M-PG1 Min. 0.5-inch Structodek High Density Fiberboard M-PG1 None BP-AA or SBS- AA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -180.0 C-56. Structural concrete None Min. 1.5-inch ACFoam II, ENRGY 3 or H-Shield M-OSFA Min. 0.25-inch DensDeck M-OSFA None BP-AA or SBS- AA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -232.5 C-57. Structural concrete None Min. 1.5-inch ACFoam II, ENRGY 3 or H-Shield M-PG1 Min. 0.25-inch DensDeck M-PG1 None BP-AA or SBS- AA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -240.0 C-58. Structural concrete None Min. 1.5-inch ACFoam II or H- Shield M-PG1 Min. 0.25-inch DensDeck Prime M-PG1 None BP-AA, SBS-AA (Optional) BP- AA, SBS-AA or SBS-TA SBS-AA -297.5 C-59. Structural concrete None Min. 2-inch ACFoam II, ENRGY 3 or H-Shield M-OSFA or M- PG1 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board M-OSFA or M- PG1 None BP-AA or SBS- AA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -225.0 C-60. Structural concrete None Min. 2-inch ACFoam II, ENRGY 3 or H-Shield M-OSFA or M- PG1 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board M-OSFA or M- PG1 None SBS-TA or APP- TA (Optional) SBS- TA or APP-TA APP-TA -232.5 C-61. Structural concrete None Min. 1.5-inch ACFoam II or H- Shield M-OSFA or M- PG1 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board M-OSFA or M- PG1 None APP-TA (Optional) APP- TA APP-TA -252.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R29 for FL2533-R28 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 29: 04/14/2022 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 34 of 70 TABLE 3A: STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER SEE NOTE 16 FOR VAPOR BARRIER OPTIONS Sys. No. Deck (Note 1) Primer Base Insulation Layer Top Insulation Layer Primer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply C-62. Structural concrete None Min. 1.5-inch ACFoam II or H- Shield M-OSFA or M- PG1 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board M-OSFA or M- PG1 None BP-AA, SBS-AA or SBS-TA (Optional) BP- AA, SBS-AA or SBS-TA SBS-AA -297.5 C-63. Structural concrete None 0.5-inch Structodek High Density Fiberboard M-PG1 None N/A None BP-AA, SBS-AA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -195.0 C-64. Structural concrete None Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board M-PG1 None N/A None BP-AA, SBS-AA, SBS-TA or APP- TA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -195.0 C-65. Structural concrete None (Optional) Min. 1.5-inch ACFoam II or H-Shield M-OSFA or M- PG1, 6-inch o.c. Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board M-OSFA or M- PG1, 6-inch o.c. None SBS-AA or SBS- TA (Optional) SBS- AA or SBS-TA SBS-AA -315.0 C-66. Structural concrete None (Optional) Min. 1.5-inch ACFoam II or H-Shield M-OSFA or M- PG1, 6-inch o.c. Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board M-OSFA or M- PG1, 6-inch o.c. None Flintlastic STA or Flintlastic STA Plus (Optional) APP- TA APP-TA -315.0 C-67. Structural concrete None Min. 1.5-inch ACFoam II or H- Shield Insta Stik Min. 0.25-inch DensDeck Prime Insta Stik None BP-AA, SBS-AA (Optional) BP- AA, SBS-AA or SBS-TA SBS-AA -297.5 C-68. Structural concrete None Min. 2-inch ACFoam II, ENRGY 3 or H-Shield Insta Stik Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Insta Stik None BP-AA or SBS- AA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -225.0 C-69. Structural concrete None Min. 2-inch ACFoam II, ENRGY 3 or H-Shield Insta Stik Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Insta Stik None SBS-TA or APP- TA (Optional) SBS- TA or APP-TA APP-TA -232.5 C-70. Structural concrete None Min. 1.5-inch ACFoam II or H- Shield Insta Stik Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Insta Stik None APP-TA (Optional) APP- TA APP-TA -252.5 C-71. Structural concrete None Min. 1.5-inch ACFoam II or H- Shield Insta Stik Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Insta Stik None BP-AA, SBS-AA or SBS-TA (Optional) BP- AA, SBS-AA or SBS-TA SBS-AA -297.5 C-72. Structural concrete None 0.5-inch Structodek High Density Fiberboard Insta Stik None N/A None BP-AA, SBS-AA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -195.0 C-73. Structural concrete None Min. 0.25-inch SECUROCK Gypsum- Fiber Roof Board Insta Stik None N/A None BP-AA, SBS-AA, SBS-TA or APP- TA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -195.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R29 for FL2533-R28 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 29: 04/14/2022 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 35 of 70 TABLE 3A: STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER SEE NOTE 16 FOR VAPOR BARRIER OPTIONS Sys. No. Deck (Note 1) Primer Base Insulation Layer Top Insulation Layer Primer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply C-74. Structural concrete None Min. 1.5-inch ACFoam II, ENRGY 3 or H-Shield OB500 Min. 0.5-inch Structodek High Density Fiberboard OB500 None BP-AA or SBS- AA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -120.0 C-75. Structural concrete None Min. 1.5-inch ACFoam II OB500 Min. 0.25-inch DensDeck or DensDeck Prime OB500 None BP-AA, SBS-AA, SBS-TA or APP- TA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -150.0 C-76. Structural concrete None Min. 1.5-inch ACFoam II or H- Shield OB500 Min. 0.25-inch DensDeck Prime OB500 None BP-AA, SBS-AA or SBS-TA (Optional) BP- AA, SBS-AA or SBS-TA SBS-AA -297.5 C-77. Structural concrete None Min. 2-inch ACFoam II, ENRGY 3 or H-Shield OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 None BP-AA or SBS- AA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -225.0 C-78. Structural concrete None Min. 2-inch ACFoam II, ENRGY 3 or H-Shield OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 None SBS-TA or APP- TA (Optional) SBS- TA or APP-TA APP-TA -232.5 C-79. Structural concrete None Min. 1.5-inch ACFoam II or H- Shield OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 None APP-TA (Optional) APP- TA APP-TA -252.5 C-80. Structural concrete None Min. 1.5-inch ACFoam II or H- Shield OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 None BP-AA, SBS-AA or SBS-TA (Optional) BP- AA, SBS-AA or SBS-TA SBS-AA -297.5 C-81. Structural concrete None 0.5-inch Structodek High Density Fiberboard OB500 None N/A None BP-AA, SBS-AA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -195.0 C-82. Structural concrete None Min. 0.25-inch SECUROCK Gypsum- Fiber Roof Board OB500 None N/A None BP-AA, SBS-AA, SBS-TA or APP- TA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -195.0 C-83. Structural concrete None Min. 1-inch ENRGY 3, H-Shield or H-Shield CG or min. 1.5-inch Multi- Max FA3 or Ultra-Max Polyset BM or Polyset CRA Min. 0.5-inch Structodek High Density Fiberboard Polyset CRA None BP-AA or SBS- AA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -180.0 C-84. Structural concrete None Min. 1-inch ENRGY 3, H-Shield, or H-Shield CG, min. 1.3-inch ACFoam III or min. 1.5-inch Multi-Max FA3 or Ultra-Max Polyset BM or Polyset CRA Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Polyset BM or Polyset CRA None BP-AA or SBS- AA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -225.0 C-85. Structural concrete None Min. 1-inch ENRGY 3, H-Shield or H-Shield CG or min. 1.5-inch Multi- Max FA3 or Ultra-Max Polyset BM or Polyset CRA Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Polyset BM or Polyset CRA None SBS-TA or APP- TA (Optional) SBS- TA or APP-TA APP-TA -232.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R29 for FL2533-R28 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 29: 04/14/2022 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 36 of 70 TABLE 3A: STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER SEE NOTE 16 FOR VAPOR BARRIER OPTIONS Sys. No. Deck (Note 1) Primer Base Insulation Layer Top Insulation Layer Primer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply C-86. Structural concrete None Min. 1-inch ENRGY 3, H-Shield or H-Shield CG or min. 1.5-inch Multi- Max FA3 or Ultra-Max Polyset BM or Polyset CRA Min. 0.25-inch DensDeck Polyset BM or Polyset CRA None BP-AA or SBS- AA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -240.0 C-87. Structural concrete None 0.5-inch Structodek High Density Fiberboard Polyset BM or Polyset CRA None N/A None BP-AA, SBS-AA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -195.0 C-88. Structural concrete None Min. 0.25-inch SECUROCK Gypsum- Fiber Roof Board Polyset BM or Polyset CRA None N/A None BP-AA, SBS-AA, SBS-TA or APP- TA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -195.0 SPOT- OR STRIP-MOPPED SYSTEMS: C-89. Structural concrete FlintPrime QD Min. 1.5-inch ACFoam II, ENRGY 3 or H-Shield hot asphalt (Optional) Additional layer(s) of base insulation hot asphalt None BP-AA3, 24- inch grid (Optional) BP- AA, SBS-AA SBS-AA -37.5 COLD-APPLIED SYSTEMS: C-90. Structural concrete None (Optional) Min. 1.5-inch ACFoam II or H-Shield M-OSFA or M- PG1 Min. 0.25-inch DEXcell FA Glass Mat Roof Board M-OSFA or M- PG1 None Flintlastic Poly SMS Base Sheet in Karnak #81 (Optional) Flintlastic Poly SMS Base Sheet in Karnak #81 SBS-CA1 -90.0 C-91. Structural concrete None (Optional) Min. 1.5-inch ACFoam II or H-Shield M-OSFA or M- PG1 Min. 0.5-inch ACFoam-HD CoverBoard or H-Shield HD M-OSFA or M- PG1 None SBS-CA1 None SBS-CA1 -97.5 C-92. Structural concrete None (Optional) Min. 1.5-inch ACFoam II or H-Shield M-OSFA or M- PG1 Min. 0.5-inch ACFoam-HD CoverBoard or H-Shield HD M-OSFA or M- PG1 None SBS-CA4 None SBS-CA4 -97.5 C-93. Structural concrete None Min. 0.5-inch ACFoam II or H- Shield M-OSFA or M- PG1 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board M-OSFA or M- PG1 None SBS-CA1 None SBS-CA1 -105.0 C-94. Structural concrete None Min. 0.5-inch ACFoam II or H- Shield M-OSFA or M- PG1 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board M-OSFA or M- PG1 None SBS-CA4 None SBS-CA4 -105.0 C-95. Structural concrete None (Optional) Min. 1.5-inch ACFoam II or H-Shield M-OSFA or M- PG1, 6-inch o.c. Min. 0.25-inch DEXcell FA Glass Mat Roof Board M-OSFA or M- PG1, 6-inch o.c. None Flintlastic Poly SMS Base Sheet in Karnak #81 (Optional) Flintlastic Poly SMS Base Sheet in Karnak #81 SBS-CA1 -112.5 C-96. Structural concrete None (Optional) Min. 0.5-inch ACFoam II or H-Shield OB500 Min. 1.5-inch ACFoam III or H-Shield CG OB500 None SBS-CA1 None SBS-CA1 -82.5 C-97. Structural concrete None Min. 0.5-inch ACFoam II or H- Shield OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 None SBS-CA1 None SBS-CA1 -105.0 C-98. Structural concrete None Min. 0.5-inch ACFoam II or H- Shield OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 None SBS-CA4 None SBS-CA4 -105.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R29 for FL2533-R28 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 29: 04/14/2022 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 37 of 70 TABLE 3A: STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER SEE NOTE 16 FOR VAPOR BARRIER OPTIONS Sys. No. Deck (Note 1) Primer Base Insulation Layer Top Insulation Layer Primer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply C-99. Structural concrete None (Optional) Min. 0.5-inch ACFoam II or H-Shield Polyset BM or Polyset CRA Min. 1.5-inch ACFoam III or H-Shield CG Polyset BM or Polyset CRA None SBS-CA1 None SBS-CA1 -82.5 C-100. Structural concrete None Min. 0.5-inch ACFoam II or H- Shield Polyset BM or Polyset CRA Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Polyset BM or Polyset CRA None SBS-CA1 None SBS-CA1 -105.0 C-101. Structural concrete None Min. 0.5-inch ACFoam II or H- Shield Polyset BM or Polyset CRA Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Polyset BM or Polyset CRA None SBS-CA4 None SBS-CA4 -105.0 TABLE 3B: STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-3: BONDED TEMP ROOF, BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Primer Temp Roof Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply COLD-APPLIED SYSTEMS: C-102. Structural concrete FlintPrime QD Flintlastic SA PlyBase, self-adhered (Optional) Min. 0.5-inch ACFoam II or H-Shield OB500 Min. 1.5-inch ACFoam III or H- Shield CG OB500 SBS-CA1 None SBS-CA1 -82.5 C-103. Structural concrete FlintPrime QD Flintlastic SA PlyBase, self-adhered Min. 0.5-inch ACFoam II or H- Shield OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 SBS-CA1 None SBS-CA1 -82.5 C-104. Structural concrete FlintPrime QD Flintlastic SA PlyBase, self-adhered Min. 0.5-inch ACFoam II or H- Shield OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 SBS-CA4 None SBS-CA4 -82.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R29 for FL2533-R28 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 29: 04/14/2022 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 38 of 70 TABLE 3C: STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE F: NON-INSULATED, BONDED ROOF COVER System No. Deck (Note 1) Primer Roof Cover (Note 15) MDP (psf) Base Ply Ply Cap Ply SELF-ADHERING SYSTEMS: C-105. Structural concrete FlintPrime QD SBS-SA (Optional) SBS-SA SBS-SA -630.0 HYBRID SYSTEMS: C-106. Structural concrete FlintPrime QD Flintlastic Ultra Glass SA (Optional) SBS-AA SBS-AA -135.0 C-107. Structural concrete FlintPrime QD SBS-SA-H (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -150.0 C-108. Structural concrete FlintPrime QD Flintlastic Ultra Glass SA (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -322.5 C-109. Structural concrete FlintPrime QD SBS-SA-H (Optional) BP-AA, SBS-AA SBS-AA -240.0 C-110. Structural concrete FlintPrime QD BP-AA, SBS-AA SBS-SA-H SBS-AA, SBS-TA, APP-TA -635.0 CONVENTIONAL SYSTEMS: C-111. Structural concrete FlintPrime QD APP-TA (Optional) APP-TA APP-TA -420.0 C-112. Structural concrete FlintPrime QD BP-AA, SBS-AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA or APP-TA -635.0 COLD-APPLIED SYSTEMS: C-113. Structural concrete FlintPrime QD SBS-CA1 (Optional) SBS-CA1 SBS-CA1 -262.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R29 for FL2533-R28 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 29: 04/14/2022 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 39 of 70 TABLE 4A: LIGHTWEIGHT CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Lightweight Concrete (Note 14) Base Insulation Layer Coverboard Roof Cover (Note 15) MDP (psf) Type Attach Type Attach Base Ply Ply Cap Ply CELCORE (FL2037): SELF-ADHERING SYSTEMS: LWC-1 Min. 22 ga., Type BV, Grade 33 steel, 6 ft span Min. 300 psi Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture One or more layer(s), min. 1.5-inch ACFoam II, ACFoam III, H-Shield or H-Shield CG M-OSFA Min. 0.25-inch SECUROCK Gypsum- Fiber Roof Board M-OSFA SBS-SA (Optional) SBS- SA SBS-SA -52.5 LWC-2 Min. 22 ga., Type BV, Grade 33 steel, 6 ft span Min. 300 psi Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture One or more layer(s), min. 1.5-inch ACFoam II, ACFoam III, H-Shield or H-Shield CG M-PG1 Min. 0.25-inch SECUROCK Gypsum- Fiber Roof Board M-PG1 SBS-SA (Optional) SBS- SA SBS-SA -52.5 LWC-3 Min. 22 ga., Type BV, Grade 33 steel, 6 ft span Min. 300 psi Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture One or more layer(s), min. 1.5-inch ACFoam II, ACFoam III, H-Shield or H-Shield CG OB500 Min. 0.25-inch SECUROCK Gypsum- Fiber Roof Board OB500 SBS-SA (Optional) SBS- SA SBS-SA -52.5 LWC-4 Min. 22 ga., Type BV, Grade 33 steel, 6 ft span Min. 300 psi Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture One or more layer(s), min. 1.5-inch ACFoam II, ACFoam III, H-Shield or H-Shield CG Polyset BM Min. 0.25-inch SECUROCK Gypsum- Fiber Roof Board Polyset BM SBS-SA (Optional) SBS- SA SBS-SA -52.5 LWC-5 Min. 22 ga., Type BV, Grade 33 steel, 6 ft span Min. 300 psi Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture One or more layer(s), min. 1.5-inch ACFoam II, ACFoam III, H-Shield or H-Shield CG Polyset CRA Min. 0.25-inch SECUROCK Gypsum- Fiber Roof Board Polyset CRA SBS-SA (Optional) SBS- SA SBS-SA -52.5 HYBRID SYSTEMS: LWC-6 Min. 22 ga., Type BV, Grade 33 steel, 6 ft span Min. 300 psi Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture One or more layer(s), min. 1.5-inch ACFoam II, ACFoam III, H-Shield or H-Shield CG M-OSFA, M-PG1, OB500, Polyset BM, Polyset CRA (Optional) Min. 0.25- inch SECUROCK Gypsum-Fiber Roof Board M-OSFA, M- PG1, OB500, Polyset BM, Polyset CRA SBS-SA-H (Optional) SBS- AA, SBS-TA or APP-TA SBS-AA or APP-TA -52.5 CONVENTIONAL SYSTEMS: LWC-7 Min. 22 ga., Type BV, Grade 33 steel, 6 ft span Min. 300 psi Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture One or more layer(s), min. 1.5-inch ACFoam II, ACFoam III, H-Shield or H-Shield CG M-OSFA Min. 0.25-inch SECUROCK Gypsum- Fiber Roof Board M-OSFA BP-AA or SBS-AA, SBS- TA or APP-TA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -52.5 LWC-8 Min. 22 ga., Type BV, Grade 33 steel, 6 ft span Min. 300 psi Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture One or more layer(s), min. 1.5-inch ACFoam II, ACFoam III, H-Shield or H-Shield CG M-PG1 Min. 0.25-inch SECUROCK Gypsum- Fiber Roof Board M-PG1 BP-AA or SBS-AA, SBS- TA or APP-TA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -52.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R29 for FL2533-R28 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 29: 04/14/2022 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 40 of 70 TABLE 4A: LIGHTWEIGHT CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Lightweight Concrete (Note 14) Base Insulation Layer Coverboard Roof Cover (Note 15) MDP (psf) Type Attach Type Attach Base Ply Ply Cap Ply LWC-9 Min. 22 ga., Type BV, Grade 33 steel, 6 ft span Min. 300 psi Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture One or more layer(s), min. 1.5-inch ACFoam II, ACFoam III, H-Shield or H-Shield CG OB500 Min. 0.25-inch SECUROCK Gypsum- Fiber Roof Board OB500 BP-AA or SBS-AA, SBS- TA or APP-TA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -52.5 LWC-10 Min. 22 ga., Type BV, Grade 33 steel, 6 ft span Min. 300 psi Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture One or more layer(s), min. 1.5-inch ACFoam II, ACFoam III, H-Shield or H-Shield CG Polyset BM Min. 0.25-inch SECUROCK Gypsum- Fiber Roof Board Polyset BM BP-AA or SBS-AA, SBS- TA or APP-TA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -52.5 LWC-11 Min. 22 ga., Type BV, Grade 33 steel, 6 ft span Min. 300 psi Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture One or more layer(s), min. 1.5-inch ACFoam II, ACFoam III, H-Shield or H-Shield CG Polyset CRA Min. 0.25-inch SECUROCK Gypsum- Fiber Roof Board Polyset CRA BP-AA or SBS-AA, SBS- TA or APP-TA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -52.5 ELASTIZELL (FL4994): COLD APPLIED SYSTEMS: LWC-12 Min. 22 ga., Type BV, Grade 33 steel, 5 ft span Min. 350 psi, min 2-inch Range II Elastizell with Zell-Crete Fibers. Min. 1.5-inch H-Shield CG OB500, 6- inch o.c. (Optional) Additional layers of base insulation OB500, 6-inch o.c. BP-CA3 or SBS-CA3 (Optional) BP- CA3 or SBS-CA3 SBS-CA3 -60.0 LWC-13 Min. 22 ga., Type BV, Grade 33 steel, 5 ft span Min. 350 psi, min 2-inch Range II Elastizell with Zell-Crete Fibers. When walkable, attach LWC with Trufast #14 HD with Trufast 3” Metal Insulation Plates at 1 per 8 ft2 through to the structural deck. Min. 1.5-inch H-Shield CG OB500, 6- inch o.c. (Optional) Additional layers of base insulation OB500, 6-inch o.c. BP-CA3 or SBS-CA3 (Optional) BP- CA3 or SBS-CA3 SBS-CA3 -67.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R29 for FL2533-R28 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 29: 04/14/2022 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 41 of 70 TABLE 4B: LIGHTWEIGHT CONCRETE OVER STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Lightweight Concrete (Note 14) Base Insulation Layer Coverboard Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Primer Base Ply Ply Cap Ply CELCORE (FL2037): SELF-ADHERING SYSTEMS: LWC-14 Structural concrete Min. 300 psi, min. 2-inch Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture; treated with Celcore PVA Curing Compound One or more layer(s), min. 1.5-inch ACFoam II, ACFoam III, H-Shield or H- Shield CG M-OSFA Min. 0.25-inch DensDeck M-OSFA FlintPrime QD SBS-SA (Optional) SBS-SA SBS-SA -90.0 LWC-15 Structural concrete Min. 300 psi, min. 2-inch Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture; treated with Celcore PVA Curing Compound One or more layer(s), min. 1.5-inch ACFoam II, ACFoam III, H-Shield or H- Shield CG M-OSFA Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board M-OSFA None SBS-SA (Optional) SBS-SA SBS-SA -90.0 LWC-16 Structural concrete Min. 300 psi, min. 2-inch Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture; treated with Celcore PVA Curing Compound and surfaced with Celcore Sanded Bonding Surface (SBS) One or more layer(s), min. 1.5-inch ACFoam II, ACFoam III, H-Shield or H- Shield CG M-OSFA Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board M-OSFA None SBS-SA (Optional) SBS-SA SBS-SA -172.5 LWC-17 Structural concrete Min. 300 psi, min. 2-inch Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture; treated with Celcore PVA Curing Compound and surfaced with Celcore Sanded Bonding Surface (SBS) One or more layer(s), min. 1.5-inch ACFoam II, ACFoam III, H-Shield or H- Shield CG M-OSFA Min. 0.25-inch DensDeck M-OSFA FlintPrime QD SBS-SA (Optional) SBS-SA SBS-SA -192.5 LWC-18 Structural concrete Min. 300 psi, min. 2-inch Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture; treated with Celcore PVA Curing Compound and surfaced with Celcore Sanded Bonding Surface (SBS) One or more layer(s), min. 1.5-inch ACFoam II, ACFoam III, H-Shield or H- Shield CG M-OSFA Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board M-OSFA FlintPrime QD SBS-SA (Optional) SBS-SA SBS-SA -217.5 LWC-19 Structural concrete Min. 300 psi, min. 2-inch Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture; treated with Celcore PVA Curing Compound One or more layer(s), min. 1.5-inch ACFoam II, ACFoam III, H-Shield or H- Shield CG M-PG1 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board M-PG1 None SBS-SA (Optional) SBS-SA SBS-SA -172.5 LWC-20 Structural concrete Min. 300 psi, min. 2-inch Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture; treated with Celcore PVA Curing Compound and surfaced with Celcore Sanded Bonding Surface (SBS) One or more layer(s), min. 1.5-inch ACFoam II, ACFoam III, H-Shield or H- Shield CG M-PG1 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board M-PG1 None SBS-SA (Optional) SBS-SA SBS-SA -172.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R29 for FL2533-R28 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 29: 04/14/2022 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 42 of 70 TABLE 4B: LIGHTWEIGHT CONCRETE OVER STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Lightweight Concrete (Note 14) Base Insulation Layer Coverboard Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Primer Base Ply Ply Cap Ply LWC-21 Structural concrete Min. 300 psi, min. 2-inch Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture; treated with Celcore PVA Curing Compound One or more layer(s), min. 1.5-inch ACFoam II, ACFoam III, H-Shield or H- Shield CG M-PG1 Min. 0.25-inch DensDeck M-PG1 FlintPrime QD SBS-SA (Optional) SBS-SA SBS-SA -192.5 LWC-22 Structural concrete Min. 300 psi, min. 2-inch Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture; treated with Celcore PVA Curing Compound and surfaced with Celcore Sanded Bonding Surface (SBS) One or more layer(s), min. 1.5-inch ACFoam II, ACFoam III, H-Shield or H- Shield CG M-PG1 Min. 0.25-inch DensDeck M-PG1 FlintPrime QD SBS-SA (Optional) SBS-SA SBS-SA -192.5 LWC-23 Structural concrete Min. 300 psi, min. 2-inch Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture; treated with Celcore PVA Curing Compound One or more layer(s), min. 1.5-inch ACFoam II, ACFoam III, H-Shield or H- Shield CG M-PG1 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board M-PG1 FlintPrime QD SBS-SA (Optional) SBS-SA SBS-SA -240.0 LWC-24 Structural concrete Min. 300 psi, min. 2-inch Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture; treated with Celcore PVA Curing Compound and surfaced with Celcore Sanded Bonding Surface (SBS) One or more layer(s), min. 1.5-inch ACFoam II, ACFoam III, H-Shield or H- Shield CG M-PG1 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board M-PG1 FlintPrime QD SBS-SA (Optional) SBS-SA SBS-SA -232.5 LWC-25 Structural concrete Min. 300 psi Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture One or more layer(s), min. 1.5-inch ACFoam II, ACFoam III, H-Shield or H- Shield CG OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 None SBS-SA (Optional) SBS-SA SBS-SA -172.5 LWC-26 Structural concrete Min. 200 psi, min. 2-inch Celcore Cellular Concrete Min. 1-inch ENRGY 3, H- Shield or H-Shield CG or min. 1.5-inch Multi-Max FA3 or Ultra-Max Polyset CRA Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Polyset CRA None SBS-SA (Optional) SBS-SA SBS-SA -172.5 LWC-27 Structural concrete Min. 300 psi Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture One or more layer(s), min. 1.5-inch ACFoam II, ACFoam III, H-Shield or H- Shield CG Polyset CRA Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Polyset CRA None SBS-SA (Optional) SBS-SA SBS-SA -172.5 LWC-28 Structural concrete Min. 200 psi, min. 2-inch Celcore Cellular Concrete Min. 1-inch ENRGY 3, H- Shield or H-Shield CG or min. 1.5-inch Multi-Max FA3 or Ultra-Max Polyset CRA Min. 0.25-inch DensDeck Polyset CRA FlintPrime QD SBS-SA (Optional) SBS-SA SBS-SA -180.0 HYBRID SYSTEMS: NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R29 for FL2533-R28 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 29: 04/14/2022 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 43 of 70 TABLE 4B: LIGHTWEIGHT CONCRETE OVER STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Lightweight Concrete (Note 14) Base Insulation Layer Coverboard Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Primer Base Ply Ply Cap Ply LWC-29 Structural concrete Min. 300 psi, min. 2-inch Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture; treated with Celcore PVA Curing Compound One or more layer(s), min. 1.5-inch ACFoam II or H- Shield M-OSFA (Optional) Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board M-OSFA None SBS-SA-H (Optional) SBS-AA, SBS- TA, APP-TA SBS-AA, SBS-TA, APP-TA -90.0 LWC-30 Structural concrete Min. 300 psi, min. 2-inch Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture; treated with Celcore PVA Curing Compound and surfaced with Celcore Sanded Bonding Surface (SBS) One or more layer(s), min. 1.5-inch ACFoam II or H- Shield M-OSFA (Optional) Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board M-OSFA None SBS-SA-H (Optional) SBS-AA, SBS- TA, APP-TA SBS-AA, SBS-TA, APP-TA -217.5 LWC-31 Structural concrete Min. 300 psi, min. 2-inch Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture; treated with Celcore PVA Curing Compound and surfaced with Celcore Sanded Bonding Surface (SBS) One or more layer(s), min. 1.5-inch ACFoam II or H- Shield M-PG1 (Optional) Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board M-PG1 None SBS-SA-H (Optional) SBS-AA, SBS- TA, APP-TA SBS-AA, SBS-TA, APP-TA -232.5 LWC-32 Structural concrete Min. 300 psi, min. 2-inch Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture; treated with Celcore PVA Curing Compound One or more layer(s), min. 1.5-inch ACFoam II or H- Shield M-PG1 (Optional) Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board M-PG1 None SBS-SA-H (Optional) SBS-AA, SBS- TA, APP-TA SBS-AA, SBS-TA, APP-TA -240.0 LWC-33 Structural concrete Min. 300 psi Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture One or more layer(s), min. 1.5-inch ACFoam II, ACFoam III, H-Shield or H- Shield CG OB500 (Optional) Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 None SBS-SA-H (Optional) SBS-AA, SBS- TA or APP-TA SBS-AA or APP- TA -215.0 LWC-34 Structural concrete Min. 300 psi Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture One or more layer(s), min. 1.5-inch ACFoam II, ACFoam III, H-Shield or H- Shield CG Polyset BM or Polyset CRA (Optional) Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Polyset BM or Polyset CRA None SBS-SA-H (Optional) SBS-AA, SBS- TA or APP-TA SBS-AA or APP- TA -215.0 CONVENTIONAL SYSTEMS: LWC-35 Structural concrete Min. 300 psi, min. 2-inch Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture; treated with Celcore PVA Curing Compound One or more layer(s), min. 1.5-inch ACFoam II, ACFoam III, H-Shield or H- Shield CG M-OSFA Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board M-OSFA None BP-AA, SBS- AA, SBS-TA or APP-TA (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP- TA -90.0 LWC-36 Structural concrete Min. 300 psi, min. 2-inch Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture; treated with Celcore PVA Curing Compound and surfaced with Celcore Sanded Bonding Surface (SBS) One or more layer(s), min. 1.5-inch ACFoam II, ACFoam III, H-Shield or H- Shield CG M-OSFA Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board M-OSFA None BP-AA, SBS- AA, SBS-TA or APP-TA (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP- TA -217.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R29 for FL2533-R28 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 29: 04/14/2022 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 44 of 70 TABLE 4B: LIGHTWEIGHT CONCRETE OVER STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Lightweight Concrete (Note 14) Base Insulation Layer Coverboard Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Primer Base Ply Ply Cap Ply LWC-37 Structural concrete Min. 300 psi, min. 2-inch Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture; treated with Celcore PVA Curing Compound One or more layer(s), min. 1.5-inch ACFoam II, ACFoam III, H-Shield or H- Shield CG M-PG1 Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board M-PG1 None BP-AA, SBS- AA, SBS-TA or APP-TA (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP- TA -240.0 LWC-38 Structural concrete Min. 300 psi, min. 2-inch Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture; treated with Celcore PVA Curing Compound and surfaced with Celcore Sanded Bonding Surface (SBS) One or more layer(s), min. 1.5-inch ACFoam II, ACFoam III, H-Shield or H- Shield CG M-PG1 Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board M-PG1 None BP-AA, SBS- AA, SBS-TA or APP-TA (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP- TA -232.5 LWC-39 Structural concrete Min. 300 psi Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture One or more layer(s), min. 1.5-inch ACFoam II, ACFoam III, H-Shield or H- Shield CG OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 None BP-AA, SBS-AA, SBS-TA or APP-TA (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP- TA -215.0 LWC-40 Structural concrete Min. 300 psi Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture One or more layer(s), min. 1.5-inch ACFoam II, ACFoam III, H-Shield or H- Shield CG Polyset BM Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Polyset BM None BP-AA, SBS-AA, SBS-TA or APP-TA (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP- TA -215.0 LWC-41 Structural concrete Min. 200 psi, min. 2-inch Celcore Cellular Concrete Min. 1-inch ENRGY 3, H- Shield or H-Shield CG or min. 1.5-inch Multi-Max FA3 or Ultra-Max Polyset CRA Min. 0.5-inch Structodek High Density Fiberboard Polyset CRA None BP-AA or SBS-AA (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP- TA -180.0 LWC-42 Structural concrete Min. 200 psi, min. 2-inch Celcore Cellular Concrete Min. 1-inch ENRGY 3, H- Shield or H-Shield CG or min. 1.5-inch Multi-Max FA3 or Ultra-Max Polyset CRA Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board or DensDeck or DensDeck Prime Polyset CRA None BP-AA, SBS- AA, SBS-TA or APP-TA (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP- TA -180.0 LWC-43 Structural concrete Min. 300 psi Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture One or more layer(s), min. 1.5-inch ACFoam II, ACFoam III, H-Shield or H- Shield CG Polyset CRA Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Polyset CRA None BP-AA, SBS-AA, SBS-TA or APP-TA (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP- TA -215.0 ELASTIZELL (FL4994): SELF-ADHERING SYSTEMS: LWC-44 Structural concrete Min. 200 psi, min. 2-inch Elastizell Min. 1.5-inch ACFoam II or ENRGY 3 OB500 Min. 0.25-inch DensDeck OB500 FlintPrime QD SBS-SA (Optional) SBS-SA SBS-SA -150.0 LWC-45 Structural concrete Min. 200 psi, min. 2-inch Elastizell Min. 1.5-inch ACFoam II, ENRGY 3 or H-Shield OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 None SBS-SA (Optional) SBS-SA SBS-SA -172.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R29 for FL2533-R28 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 29: 04/14/2022 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 45 of 70 TABLE 4B: LIGHTWEIGHT CONCRETE OVER STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Lightweight Concrete (Note 14) Base Insulation Layer Coverboard Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Primer Base Ply Ply Cap Ply LWC-46 Structural concrete Min. 200 psi, min. 2-inch Elastizell Min. 1-inch ENRGY 3, H- Shield or H-Shield CG or min. 1.5-inch Multi-Max FA3 or Ultra-Max Polyset CRA Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Polyset CRA None SBS-SA (Optional) SBS-SA SBS-SA -172.5 LWC-47 Structural concrete Min. 200 psi, min. 2-inch Elastizell Min. 1-inch ENRGY 3, H- Shield or H-Shield CG or min. 1.5-inch Multi-Max FA3 or Ultra-Max Polyset CRA Min. 0.25-inch DensDeck Polyset CRA FlintPrime QD SBS-SA (Optional) SBS-SA SBS-SA -180.0 CONVENTIONAL SYSTEMS: LWC-48 Structural concrete Min. 200 psi, min. 2-inch Elastizell Min. 1.5-inch ACFoam II OB500 Min. 0.25-inch DensDeck or DensDeck Prime OB500 None BP-AA, SBS- AA, SBS-TA or APP-TA (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP- TA -150.0 LWC-49 Structural concrete Min. 200 psi, min. 2-inch Elastizell Min. 2-inch ACFoam II, ENRGY 3 or H-Shield OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 None BP-AA, SBS-AA, SBS-TA or APP-TA (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP- TA -225.0 LWC-50 Structural concrete Min. 200 psi, min. 2-inch Elastizell Min. 1-inch ENRGY 3, H- Shield or H-Shield CG or min. 1.5-inch Multi-Max FA3 or Ultra-Max Polyset CRA Min. 0.5-inch Structodek High Density Fiberboard Polyset CRA None BP-AA or SBS-AA (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP- TA -180.0 LWC-51 Structural concrete Min. 200 psi, min. 2-inch Elastizell Min. 1-inch ENRGY 3, H- Shield or H-Shield CG or min. 1.5-inch Multi-Max FA3 or Ultra-Max Polyset CRA Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board or DensDeck or DensDeck Prime Polyset CRA None BP-AA, SBS- AA, SBS-TA or APP-TA (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP- TA -180.0 COLD APPLIED SYSTEMS: LWC-52 Structural concrete Min. 350 psi, min 2-inch Elastizell with Zell-Crete Fibers. Min. 1.5-inch H-Shield CG OB500, 6- inch o.c. (Optional) Additional layers of base insulation OB500, 6-inch o.c. None BP-CA3 or SBS-CA3 (Optional) BP-CA3 or SBS-CA3 SBS-CA3 -60.0 LWC-53 Structural concrete Min. 350 psi, min 2-inch Range II Elastizell with Zell-Crete Fibers. When walkable, attach LWC with Trufast #14HD with Trufast 3” Metal Insulation Plates at 1 per 8 ft2 through to the structural deck. Min. 1.5-inch H-Shield CG OB500, 6- inch o.c. (Optional) Additional layers of base insulation OB500, 6-inch o.c. None BP-CA3 or SBS-CA3 (Optional) BP-CA3 or SBS-CA3 SBS-CA3 -67.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R29 for FL2533-R28 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 29: 04/14/2022 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 46 of 70 TABLE 4C: LIGHTWEIGHT INSULATING CONCRETE OVER STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: LWC TO DECK, BONDED VAPOR BARRIER, BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Lightweight Concrete (Note 14) Vapor Barrier Base Insulation Layer Coverboard Primer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6&7) Type Attach (Notes 6&7) Base Ply Ply Cap Ply PRE-EXISTENT CELLULAR LWC: SELF-ADHERING SYSTEMS: LWC-54 Min. 22 ga., Type BV, Grade 40 steel Min. 400 psi, Min. 2- inch, pre-existent cellular lightweight concrete, Repair LWC spalls with Celcore SBS (Sanded Bonding Surface) Flintlastic Ultra Poly SMS Base Sheet applied in HB Fuller “Millennium Hurricane Force Membrane Adhesive HS”, ribbons max. 6-inch o.c. 3-inch wide side laps and 6-inch wide end laps are hot-air-welded, torch-welded or sealed with HB Fuller “Millennium Hurricane Force Lap and Flashing Adhesive” One or more layers, min. 2-inch ACFoam II or H-Shield M-OSFA or M-PG1 (Optional) 0.5- in. DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board M-OSFA or M-PG1 FlintPrime QD SBS-SA (Optional) SBS-SA SBS-SA -67.5 HYBRID SYSTEMS: LWC-55 Min. 22 ga., Type BV, Grade 40 steel Min. 400 psi, Min. 2- inch, pre-existent cellular lightweight concrete, Repair LWC spalls with Celcore SBS (Sanded Bonding Surface) Flintlastic Ultra Poly SMS Base Sheet applied in HB Fuller “Millennium Hurricane Force Membrane Adhesive HS”, ribbons max. 6-inch o.c. 3-inch wide side laps and 6-inch wide end laps are hot-air-welded, torch-welded or sealed with HB Fuller “Millennium Hurricane Force Lap and Flashing Adhesive” One or more layers, min. 2-inch ACFoam II or H-Shield M-OSFA or M-PG1 0.5-in. DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board M-OSFA or M-PG1 (Optional) FlintPrime QD SBS-SA-H (Optional) SBS-TA or APP-TA APP-TA -67.5 CONVENTIONAL SYSTEMS: LWC-56 Min. 22 ga., Type BV, Grade 40 steel Min. 400 psi, Min. 2- inch, pre-existent cellular lightweight concrete, Repair LWC spalls with Celcore SBS (Sanded Bonding Surface) Flintlastic Ultra Poly SMS Base Sheet applied in HB Fuller “Millennium Hurricane Force Membrane Adhesive HS”, ribbons max. 6-inch o.c. 3-inch wide side laps and 6-inch wide end laps are hot-air-welded, torch-welded or sealed with HB Fuller “Millennium Hurricane Force Lap and Flashing Adhesive” One or more layers, min. 2-inch ACFoam II or H-Shield M-OSFA or M-PG1 0.5-in. DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board M-OSFA or M-PG1 (Optional) FlintPrime QD SBS-TA or APP-TA (Optional) SBS-TA or APP-TA APP-TA -67.5 ELASTIZELL (FL4994): SELF-ADHERING SYSTEMS: LWC-57 Structural Concrete Min. 420 psi, min. 2-inch Elastizell All Weather/Empire Base Sheet or Flintglas MS Cap (inverted) applied in HB Fuller “Millennium Hurricane Force Membrane Adhesive HS”, ribbons max. 6- inch o.c., 3-inch wide side laps and 6-inch wide end laps are sealed with HB Fuller “Millennium Hurricane Force Lap and Flashing Adhesive” One or more layers, min. 2-inch ACFoam II or H-Shield M-OSFA or M-PG1 (Optional) 0.5- in. DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board M-OSFA or M-PG1 FlintPrime QD SBS-SA (Optional) SBS-SA SBS-SA -67.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R29 for FL2533-R28 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 29: 04/14/2022 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 47 of 70 TABLE 4C: LIGHTWEIGHT INSULATING CONCRETE OVER STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: LWC TO DECK, BONDED VAPOR BARRIER, BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Lightweight Concrete (Note 14) Vapor Barrier Base Insulation Layer Coverboard Primer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6&7) Type Attach (Notes 6&7) Base Ply Ply Cap Ply LWC-58 Structural Concrete Min. 420 psi, min. 2-inch Elastizell Flintlastic Ultra Poly SMS Base Sheet applied in HB Fuller “Millennium Hurricane Force Membrane Adhesive HS”, ribbons max. 6-inch o.c., 3-inch wide side laps and 6-inch wide end laps are hot-air-welded, torch-welded or sealed with HB Fuller “Millennium Hurricane Force Lap and Flashing Adhesive” One or more layers, min. 2-inch ACFoam II or H-Shield M-OSFA or M-PG1 (Optional) 0.5- in. DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board M-OSFA or M-PG1 FlintPrime QD SBS-SA (Optional) SBS-SA SBS-SA -67.5 HYBRID SYSTEMS: LWC-59 Structural Concrete Min. 420 psi, min. 2-inch Elastizell All Weather/Empire Base Sheet or Flintglas MS Cap (inverted) applied in HB Fuller “Millennium Hurricane Force Membrane Adhesive HS”, ribbons max. 6- inch o.c., 3-inch wide side laps and 6-inch wide end laps are sealed with HB Fuller “Millennium Hurricane Force Lap and Flashing Adhesive” One or more layers, min. 2-inch ACFoam II or H-Shield M-OSFA or M-PG1 0.5-in. DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board M-OSFA or M-PG1 (Optional) FlintPrime QD SBS-SA-H (Optional) SBS-TA or APP-TA APP-TA -67.5 LWC-60 Structural Concrete Min. 420 psi, min. 2-inch Elastizell Flintlastic Ultra Poly SMS Base Sheet applied in HB Fuller “Millennium Hurricane Force Membrane Adhesive HS”, ribbons max. 6-inch o.c., 3-inch wide side laps and 6-inch wide end laps are hot-air-welded, torch-welded or sealed with HB Fuller “Millennium Hurricane Force Lap and Flashing Adhesive” One or more layers, min. 2-inch ACFoam II or H-Shield M-OSFA or M-PG1 0.5-in. DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board M-OSFA or M-PG1 (Optional) FlintPrime QD SBS-SA-H (Optional) SBS-TA or APP-TA APP-TA -67.5 CONVENTIONAL SYSTEMS: LWC-61 Structural Concrete Min. 420 psi, min. 2-inch Elastizell All Weather/Empire Base Sheet or Flintglas MS Cap (inverted) applied in HB Fuller “Millennium Hurricane Force Membrane Adhesive HS”, ribbons max. 6- inch o.c., 3-inch wide side laps and 6-inch wide end laps are sealed with HB Fuller “Millennium Hurricane Force Lap and Flashing Adhesive” One or more layers, min. 2-inch ACFoam II or H-Shield M-OSFA or M-PG1 0.5-in. DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board M-OSFA or M-PG1 (Optional) FlintPrime QD SBS-TA or APP-TA (Optional) SBS-TA or APP-TA APP-TA -67.5 LWC-62 Structural Concrete Min. 420 psi, min. 2-inch Elastizell Flintlastic Ultra Poly SMS Base Sheet applied in HB Fuller “Millennium Hurricane Force Membrane Adhesive HS”, ribbons max. 6-inch o.c., 3-inch wide side laps and 6-inch wide end laps are hot-air-welded, torch-welded or sealed with HB Fuller “Millennium Hurricane Force Lap and Flashing Adhesive” One or more layers, min. 2-inch ACFoam II or H-Shield M-OSFA or M-PG1 0.5-in. DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board M-OSFA or M-PG1 (Optional) FlintPrime QD SBS-TA or APP-TA (Optional) SBS-TA or APP-TA APP-TA -67.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R29 for FL2533-R28 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 29: 04/14/2022 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 48 of 70 TABLE 4D: LIGHTWEIGHT CONCRETE OVER STEEL DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Lightweight Concrete (Note 14) Anchor Sheet Insulation Roof Cover (Note 15) MDP (psf) Deck Treatment Type Surface Treatment Type Fasteners Attach Base Top Attach Base Ply Ply Cap Ply PRE-EXISTENT CELLULAR LWC: SPOT- OR STRIP-MOPPED SYSTEMS: LWC-63 Min. 22 ga. steel or structural concrete deck. None Min 350 psi, min 2-inch pre- existent cellular LWIC None Flintglas MS Cap (inverted) Trufast Twin- Loc Nails 9-inch o.c. at the 4-inch side lap and 9-inch o.c. at two, equally spaced, staggered rows in the center of the sheet Min. 1.5- inch ACFoam II (Optional) Additional layers base insulation Hot asphalt BP-AA4, 18-inch o.c. (Optional) BP-AA, SBS- AA SBS-AA -60.0 Note: To qualify the LWIC under this assembly, the subject fastener shall achieve an average withdrawal of 88 lbf when tested per ANSI/SPRI FX-1 or TAS 105. CELCORE (FL2037): SELF-ADHERING SYSTEMS: LWC-64 Min. 22 ga., type BV, Grade 40 steel, 6 ft span Celcore S-1 Deck Preparation Min. 470 psi, min. 2-inch Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture Celcore PVA Curing Compound All Weather/Empire Base Sheet, Glasbase Base Sheet or Flintlastic Base 20 or Flintglas MS Cap (inverted) Trufast FM- 90 Base Sheet Fasteners 7-inch o.c. at the min. 4-inch side laps and 7-inch o.c. at two, equally spaced, staggered center rows Min. 1.5" ACFoam II (Optional) Min. 0.25- inch DensDeck Prime or SECUROCK Gypsum- Fiber Roof Board. Top surface shall be primed with FlintPrime QD. hot asphalt SBA-SA (Optional) SBS-SA SBS-SA -60.0 HYBRID SYSTEMS: LWC-65 Min. 22 ga., type BV, Grade 40 steel, 6 ft span Celcore S-1 Deck Preparation Min. 470 psi, min. 2-inch Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture Celcore PVA Curing Compound All Weather/Empire Base Sheet, Glasbase Base Sheet or Flintlastic Base 20 or Flintglas MS Cap (inverted) Trufast FM- 90 Base Sheet Fasteners 7-inch o.c. at the min. 4-inch side laps and 7-inch o.c. at two, equally spaced, staggered center rows Min. 1.5" ACFoam II (Optional) Min. 0.125- inch STURDY-DEK Asphaltic Cover Board or min. 0.25-inch DensDeck Prime or SECUROCK Gypsum- Fiber Roof Board. Top surface may be optionally primed with FlintPrime QD. hot asphalt SBS-SA-H (Optional) SBS-AA, SBS-TA or APP-TA SBS-AA or APP- TA -60.0 CONVENTIONAL SYSTEMS: NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R29 for FL2533-R28 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 29: 04/14/2022 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 49 of 70 TABLE 4D: LIGHTWEIGHT CONCRETE OVER STEEL DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Lightweight Concrete (Note 14) Anchor Sheet Insulation Roof Cover (Note 15) MDP (psf) Deck Treatment Type Surface Treatment Type Fasteners Attach Base Top Attach Base Ply Ply Cap Ply LWC-66 Min. 22 ga., type BV, Grade 40 steel, 6 ft span Celcore S-1 Deck Preparation Min. 470 psi, min. 2-inch Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture Celcore PVA Curing Compound All Weather/Empire Base Sheet, Glasbase Base Sheet or Flintlastic Base 20 or Flintglas MS Cap (inverted) Trufast FM- 90 Base Sheet Fasteners 7-inch o.c. at the min. 4-inch side laps and 7-inch o.c. at two, equally spaced, staggered center rows Min. 1.5" ACFoam II Min. 0.125-inch STURDY-DEK Asphaltic Cover Board, min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board, min. 0.5-inch Structodek High Density Fiberboard Roof Insulation or min. 0.75-inch Fesco Board (homogeneous) hot asphalt BP-AA or SBS-AA (Optional) SBS-AA, SBS-TA or APP-TA SBS-AA or APP- TA -60.0 LWC-67 Min. 22 ga., type BV, Grade 40 steel, 6 ft span Celcore S-1 Deck Preparation Min. 470 psi, min. 2-inch Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture Celcore PVA Curing Compound All Weather/Empire Base Sheet, Glasbase Base Sheet or Flintlastic Base 20 or Flintglas MS Cap (inverted) Trufast FM- 90 Base Sheet Fasteners 7-inch o.c. at the min. 4-inch side laps and 7-inch o.c. at two, equally spaced, staggered center rows Min. 1.5" ACFoam II Min. 0.125-inch STURDY-DEK Asphaltic Cover Board or min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board. Top surface may be optionally primed with FlintPrime QD. hot asphalt SBS-TA or APP-TA (Optional) SBS-TA or APP-TA APP-TA -60.0 ELASTIZELL (FL4994): SELF-ADHERING SYSTEMS: LWC-68 Min. 22 ga., type BV, Grade 40 steel, 6 ft span None Min. 490 psi, min. 2-inch Elastizell with Zell-Crete Fibers None All Weather/Empire Base Sheet, Glasbase Base Sheet or Flintlastic Base 20 or Flintglas MS Cap (inverted) Trufast FM- 90 Base Sheet Fasteners 7-inch o.c. at the min. 4-inch side laps and 7-inch o.c. at two, equally spaced, staggered center rows Min. 1.5" ACFoam II (Optional) Min. 0.25- inch DensDeck Prime or SECUROCK Gypsum- Fiber Roof Board. Top surface shall be primed with FlintPrime QD. hot asphalt SBA-SA (Optional) SBS-SA SBS-SA -67.5 HYBRID SYSTEMS: LWC-69 Min. 22 ga., type BV, Grade 40 steel, 6 ft span None Min. 490 psi, min. 2-inch Elastizell with Zell-Crete Fibers None All Weather/Empire Base Sheet, Glasbase Base Sheet or Flintlastic Base 20 or Flintglas MS Cap (inverted) Trufast FM- 90 Base Sheet Fasteners 7-inch o.c. at the min. 4-inch side laps and 7-inch o.c. at two, equally spaced, staggered center rows Min. 1.5" ACFoam II (Optional) Min. 0.125- inch STURDY-DEK Asphaltic Cover Board or min. 0.25-inch DensDeck Prime or SECUROCK Gypsum- Fiber Roof Board. Top surface may be optionally primed with FlintPrime QD. hot asphalt SBS-SA-H (Optional) SBS-AA, SBS-TA or APP-TA SBS-AA or APP- TA -67.5 CONVENTIONAL SYSTEMS: NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R29 for FL2533-R28 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 29: 04/14/2022 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 50 of 70 TABLE 4D: LIGHTWEIGHT CONCRETE OVER STEEL DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Lightweight Concrete (Note 14) Anchor Sheet Insulation Roof Cover (Note 15) MDP (psf) Deck Treatment Type Surface Treatment Type Fasteners Attach Base Top Attach Base Ply Ply Cap Ply LWC-70 Min. 22 ga., type BV, Grade 40 steel, 6 ft span None Min. 490 psi, min. 2-inch Elastizell with Zell-Crete Fibers None All Weather/Empire Base Sheet, Glasbase Base Sheet or Flintlastic Base 20 or Flintglas MS Cap (inverted) Trufast FM- 90 Base Sheet Fasteners 7-inch o.c. at the min. 4-inch side laps and 7-inch o.c. at two, equally spaced, staggered center rows Min. 1.5" ACFoam II Min. 0.125-inch STURDY-DEK Asphaltic Cover Board, min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board, min. 0.5-inch Structodek High Density Fiberboard Roof Insulation or min. 0.75-inch Fesco Board (homogeneous) hot asphalt BP-AA or SBS-AA (Optional) SBS-AA, SBS-TA or APP-TA SBS-AA or APP- TA -67.5 LWC-71 Min. 22 ga., type BV, Grade 40 steel, 6 ft span None Min. 490 psi, min. 2-inch Elastizell with Zell-Crete Fibers None All Weather/Empire Base Sheet, Glasbase Base Sheet or Flintlastic Base 20 or Flintglas MS Cap (inverted) Trufast FM- 90 Base Sheet Fasteners 7-inch o.c. at the min. 4-inch side laps and 7-inch o.c. at two, equally spaced, staggered center rows Min. 1.5" ACFoam II Min. 0.125-inch STURDY-DEK Asphaltic Cover Board or min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board. Top surface may be optionally primed with FlintPrime QD. hot asphalt SBS-TA or APP-TA (Optional) SBS-TA or APP-TA APP-TA -67.5 SPOT- OR STRIP-MOPPED SYSTEMS: LWC-72 Min. 22 ga. steel or structural concrete deck. None Min 350 psi, min 2-inch Elastizell cellular LWIC None Flintglas MS Cap (inverted) Trufast FM- 90 Base Ply Fasteners 7-inch o.c. at the 4-inch side lap and 7-inch o.c. at two, equally spaced, staggered rows in the center of the sheet Min. 1.5- inch ACFoam II (Optional) Additional layers base insulation Hot asphalt BP-AA3, 18-inch grid (Optional) BP-AA, SBS- AA SBS-AA -37.5* NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R29 for FL2533-R28 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 29: 04/14/2022 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 51 of 70 TABLE 4E: LIGHTWEIGHT CONCRETE DECKS OVER STEEL OR STRUCTURAL CONCRETE DECK – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE E-2: MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Lightweight Concrete (Note 14) Base Sheet Roof Cover (Note 15) MDP (psf) Deck Treatment LWC Surface Treatment Type Fasteners Attach Base Ply Cap Ply PRE-EXISTENT CELLULAR LIGHTWEIGHT CONCRETE: SELF-ADHERING SYSTEMS: LWC-73 Min. 22 ga., Type BV, Grade 33 steel, 5 ft span or structural concrete None Min. 300 psi, min. 2- inch pre-existent cellular lightweight insulating concrete. None Flintlastic SA NailBase Trufast Twin Loc- Nail Assembled Fastener (min. 1.8”) 7-inch o.c. at the min. 2-inch lap and 7-inch o.c. in two (2), equally spaced, staggered center rows, FlintPrime QD at stress plates SBS-SA SBS-SA -60.0 Note: To qualify the LWIC under this assembly, a 1.8-inch Trufast Twin Loc-Nail Assembled Fastener shall achieve an average withdrawal of 73 lbf when tested per ANSI/SPRI FX-1 or TAS 105 LWC-74 Min. 22 ga., Type BV, Grade 33 steel, 5 ft span or structural concrete None Min. 300 psi, min. 2- inch pre-existent cellular lightweight insulating concrete. None Flintlastic SA NailBase Trufast Twin Loc- Nail Assembled Fastener (min. 1.8”) 9-inch o.c. at the min. 2-inch lap and 9-inch o.c. in two (2), equally spaced, staggered center rows, FlintPrime QD at stress plates SBS-SA SBS-SA -60.0 Note: To qualify the LWIC under this assembly, a 1.8-inch Trufast Twin Loc-Nail Assembled Fastener shall achieve an average withdrawal of 93 lbf when tested per ANSI/SPRI FX-1 or TAS 105 HYBRID SYSTEMS: LWC-75 Min. 22 ga., Type BV, Grade 33 steel, 5 ft span or structural concrete None Min. 300 psi, min. 2- inch pre-existent cellular lightweight insulating concrete. None Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet Trufast Twin Loc- Nail Assembled Fastener (min. 1.8”) 9-inch o.c. at the 4-inch lap and 9- inch o.c. in two (2), equally spaced, staggered center rows SBS-SA-H SBS-AA or APP- TA -60.0 Note: To qualify the LWIC under this assembly, a 1.8-inch Trufast Twin Loc-Nail Assembled Fastener shall achieve an average withdrawal of 88 lbf when tested per ANSI/SPRI FX-1 or TAS 105 LWC-76 Min. 22 ga., Type BV, Grade 33 steel, 5 ft span or structural concrete None Min. 350 psi, min. 3- inch pre-existent cellular lightweight insulating concrete. None Flintlastic Base 20 or Flintlastic Poly SMS Base Sheet Trufast FM-90 Base Sheet Fasteners 7-inch o.c. at the 4-inch lap and 10- inch o.c. in two (2), equally spaced, staggered center rows SBS-SA-H SBS-AA or APP- TA -67.5 Note: To qualify the LWIC under this assembly, a 1.8-inch Trufast Twin Loc-Nail Assembled Fastener shall achieve an average withdrawal of 97 lbf when tested per ANSI/SPRI FX-1 or TAS 105 LWC-77 Min. 22 ga., Type BV, Grade 33 steel, 5 ft span or structural concrete None Min. 300 psi, min. 2- inch pre-existent cellular lightweight insulating concrete. None Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet Trufast Twin Loc- Nail Assembled Fastener (min. 1.8”) 9-inch o.c. at the 4-inch lap and 9- inch o.c. in two (2), equally spaced, staggered center rows SBS-SA-H SBS-AA or APP- TA -75.0 Note: To qualify the LWIC under this assembly, a 1.8-inch Trufast Twin Loc-Nail Assembled Fastener shall achieve an average withdrawal of 110 lbf when tested per ANSI/SPRI FX-1 or TAS 105 CONVENTIONAL SYSTEMS: NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R29 for FL2533-R28 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 29: 04/14/2022 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 52 of 70 TABLE 4E: LIGHTWEIGHT CONCRETE DECKS OVER STEEL OR STRUCTURAL CONCRETE DECK – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE E-2: MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Lightweight Concrete (Note 14) Base Sheet Roof Cover (Note 15) MDP (psf) Deck Treatment LWC Surface Treatment Type Fasteners Attach Base Ply Cap Ply LWC-78 Min. 22 ga., Type BV, Grade 33 steel, 5 ft span or structural concrete None Min. 300 psi, min. 2- inch pre-existent cellular lightweight insulating concrete. None Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet or Flintglas MS Cap (inverted) Trufast Twin Loc- Nail Assembled Fastener (min. 1.8”) 9-inch o.c. at the 4-inch lap and 9- inch o.c. in two (2), equally spaced, staggered center rows (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP- TA -60.0 Note: To qualify the LWIC under this assembly, a 1.8-inch Trufast Twin Loc-Nail Assembled Fastener shall achieve an average withdrawal of 88 lbf when tested per ANSI/SPRI FX-1 or TAS 105 LWC-79 Min. 22 ga., Type BV, Grade 33 steel, 5 ft span or structural concrete None Min. 300 psi, min. 2- inch pre-existent cellular lightweight insulating concrete. None Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet or Flintglas MS Cap (inverted) Trufast Twin Loc- Nail Assembled Fastener (min. 1.8”) 7-inch o.c. at the 4-inch lap and 7- inch o.c. in two (2), equally spaced, staggered center rows BP-AA or SBS-AA SBS-AA or APP- TA -67.5 Note: To qualify the LWIC under this assembly, a 1.8-inch Trufast Twin Loc-Nail Assembled Fastener shall achieve an average withdrawal of 77 lbf when tested per ANSI/SPRI FX-1 or TAS 105 LWC-80 Min. 22 ga., Type BV, Grade 33 steel, 5 ft span or structural concrete None Min. 350 psi, min. 3- inch pre-existent cellular lightweight insulating concrete. None Flintlastic Base 20, Flintlastic Poly SMS Base Sheet or Flintglas MS Cap (inverted) Trufast FM-90 Base Sheet Fasteners 7-inch o.c. at the 4-inch lap and 10- inch o.c. in two (2), equally spaced, staggered center rows BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP- TA -67.5 Note: To qualify the LWIC under this assembly, a 1.8-inch Trufast Twin Loc-Nail Assembled Fastener shall achieve an average withdrawal of 97 lbf when tested per ANSI/SPRI FX-1 or TAS 105 LWC-81 Min. 22 ga., Type BV, Grade 33 steel, 5 ft span or structural concrete None Min. 300 psi, min. 2- inch pre-existent cellular lightweight insulating concrete. None Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet Trufast Twin Loc- Nail Assembled Fastener (min. 1.8”) 9-inch o.c. at the 4-inch lap and 9- inch o.c. in two (2), equally spaced, staggered center rows BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP- TA -75.0 Note: To qualify the LWIC under this assembly, a 1.8-inch Trufast Twin Loc-Nail Assembled Fastener shall achieve an average withdrawal of 110 lbf when tested per ANSI/SPRI FX-1 or TAS 105 CELCORE (FL2037): SELF-ADHERING SYSTEMS: LWC-82 Min. 22 ga., type BV, Grade 40 steel, 6 ft span Celcore S-1 Deck Preparation Min. 470 psi, min. 2- inch Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture Celcore PVA Curing Compound Flintlastic SA NailBase Trufast FM-90 Base Sheet Fasteners 7-inch o.c. at the min. 4-inch side laps and 7-inch o.c. at two, equally spaced, staggered center rows SBS-SA SBS-SA -45.0 HYBRID SYSTEMS: LWC-83 Min. 22 ga., type BV, Grade 40 steel, 6 ft span Celcore S-1 Deck Preparation Min. 470 psi, min. 2- inch Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture Celcore PVA Curing Compound All Weather/Empire Base Sheet, Glasbase Base Sheet or Flintlastic Base 20 Trufast FM-90 Base Sheet Fasteners 7-inch o.c. at the min. 4-inch side laps and 7-inch o.c. at two, equally spaced, staggered center rows SBS-SA-H SBS-AA or APP- TA -45.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R29 for FL2533-R28 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 29: 04/14/2022 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 53 of 70 TABLE 4E: LIGHTWEIGHT CONCRETE DECKS OVER STEEL OR STRUCTURAL CONCRETE DECK – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE E-2: MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Lightweight Concrete (Note 14) Base Sheet Roof Cover (Note 15) MDP (psf) Deck Treatment LWC Surface Treatment Type Fasteners Attach Base Ply Cap Ply LWC-84 Min. 22 ga., type BV, Grade 40 steel, 6 ft span Celcore S-1 Deck Preparation Min. 470 psi, min. 2- inch Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture Celcore PVA Curing Compound Flintglas MS Cap (inverted) primed with FlintPrime QD Trufast FM-90 Base Sheet Fasteners 7-inch o.c. at the min. 4-inch side laps and 7-inch o.c. at two, equally spaced, staggered center rows SBS-SA-H SBS-AA or APP- TA -45.0 CONVENTIONAL SYSTEMS: LWC-85 Min. 22 ga., type BV, Grade 40 steel, 6 ft span Celcore S-1 Deck Preparation Min. 470 psi, min. 2- inch Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture Celcore PVA Curing Compound All Weather/Empire Base Sheet, Glasbase Base Sheet or Flintlastic Base 20 or Flintglas MS Cap (inverted) Trufast FM-90 Base Sheet Fasteners 7-inch o.c. at the min. 4-inch side laps and 7-inch o.c. at two, equally spaced, staggered center rows (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP- TA -45.0 LWC-86 Min. 22 ga., type B steel at max. 5 ft spans structural concrete None Min. 300 psi, min 2- inch Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture. Celcore PVA Curing Compound All Weather/Empire Base Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet Trufast FM-90 Base Sheet Fasteners 9-inch o.c. at 4-inch laps and 12-inch o.c. in two (2), equally spaced, staggered center rows (Optional) BP-AA, SBS- AA or SBS- TA SBS-AA -60.0 LWC-87 Min. 22 ga., Type BV, Grade 33 steel, 5 ft span or structural concrete None Min. 300 psi, min 2- inch Celcore Cellular Concrete. Celcore PVA Curing Compound Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet, Flintlastic Poly SMS Base Sheet or Flintglas MS Cap (inverted) Trufast FM-90 Base Sheet Fasteners 7-inch o.c. at the 3-inch lap and 7- inch o.c. in two (2), equally spaced, staggered center rows BP-AA or SBS-AA SBS-AA or APP- TA -75.0 CONCRECEL (FL5584 & FL10500): CONVENTIONAL SYSTEMS: LWC-88 Min. 22 ga., Type BV, Grade 33 steel, 5 ft span or structural concrete Concrecel Bonding Agent Min. 300 psi, min 2¼- inch Concrecel Concrete. Concrecel Curing Compound Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet, Flintlastic Poly SMS Base Sheet or Flintglas MS Cap (inverted) OMG CR Base Ply Fasteners (1.7) 7-inch o.c. at the 3-inch lap and 7- inch o.c. in two (2), equally spaced, staggered center rows (Optional) BP-AA or SBS-AA SBS-AA or APP- TA -52.5 ELASTIZELL (FL4994): SELF-ADHERING SYSTEMS: LWC-89 Min. 22 ga., type BV, Grade 40 steel, 6 ft span None Min. 490 psi, min. 2- inch Elastizell with Zell-Crete Fibers None Flintlastic SA NailBase Trufast FM-90 Base Sheet Fasteners 7-inch o.c. at the min. 4-inch side laps and 7-inch o.c. at two, equally spaced, staggered center rows SBS-SA SBS-SA -45.0 HYBRID SYSTEMS: NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R29 for FL2533-R28 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 29: 04/14/2022 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 54 of 70 TABLE 4E: LIGHTWEIGHT CONCRETE DECKS OVER STEEL OR STRUCTURAL CONCRETE DECK – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE E-2: MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Lightweight Concrete (Note 14) Base Sheet Roof Cover (Note 15) MDP (psf) Deck Treatment LWC Surface Treatment Type Fasteners Attach Base Ply Cap Ply LWC-90 Min. 26 ga. steel at max 5 ft spans or structural concrete None Min. 200 psi, min 2- inch Elastizell. None Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet or Flintlastic Poly SMS Base Sheet Trufast FM-90 Base Sheet Fasteners or Trufast Twin Loc-Nail Assembled Fasteners (1.8 inch) 7½-inch o.c. at the 4-inch lap and 7½-inch o.c. in two (2), equally spaced, staggered center rows SBS-SA-H SBS-AA or APP- TA -30.0 LWC-91 Min. 22 ga., Type BV, Grade 33 steel, 5 ft span or structural concrete None Min. 200 psi, min 2- inch Elastizell. None Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet or Flintlastic Poly SMS Base Sheet Trufast FM-90 Base Sheet Fasteners or Trufast Twin Loc-Nail Assembled Fasteners (1.8 inch) 7-inch o.c. at the 4-inch lap and 7- inch o.c. in two (2), equally spaced, staggered center rows SBS-SA-H SBS-AA or APP- TA -45.0 LWC-92 Min. 22 ga., type BV, Grade 40 steel, 6 ft span None Min. 490 psi, min. 2- inch Elastizell with Zell-Crete Fibers None All Weather/Empire Base Sheet, Glasbase Base Sheet or Flintlastic Base 20 Trufast FM-90 Base Sheet Fasteners 7-inch o.c. at the min. 4-inch side laps and 7-inch o.c. at two, equally spaced, staggered center rows SBS-SA-H SBS-AA or APP- TA -45.0 LWC-93 Min. 22 ga., type BV, Grade 40 steel, 6 ft span None Min. 490 psi, min. 2- inch Elastizell with Zell-Crete Fibers None Flintglas MS Cap (inverted) primed with FlintPrime QD Trufast FM-90 Base Sheet Fasteners 7-inch o.c. at the min. 4-inch side laps and 7-inch o.c. at two, equally spaced, staggered center rows SBS-SA-H SBS-AA or APP- TA -45.0 CONVENTIONAL SYSTEMS: LWC-94 Min. 26 ga. steel at max 5 ft spans or structural concrete None Min. 200 psi, min 2- inch Elastizell. None Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet, Flintlastic Poly SMS Base Sheet or Flintglas MS Cap (inverted) Trufast FM-90 Base Sheet Fasteners or Trufast Twin Loc-Nail Assembled Fasteners (1.8 inch) 7½-inch o.c. at the 4-inch lap and 7½-inch o.c. in two (2), equally spaced, staggered center rows (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP- TA -30.0 LWC-95 Min. 26 ga. steel at max 5 ft spans or structural concrete None Min. 200 psi, min 2- inch Elastizell. None Flintlastic APP Base T Trufast FM-90 Base Sheet Fasteners 7½-inch o.c. at the 4-inch lap and 7½-inch o.c. in two (2), equally spaced, staggered center rows (Optional) APP-TA APP-TA -30.0 LWC-96 Min. 22 ga., type BV, Grade 40 steel, 6 ft span None Min. 490 psi, min. 2- inch Elastizell with Zell-Crete Fibers None All Weather/Empire Base Sheet, Glasbase Base Sheet or Flintlastic Base 20 or Flintglas MS Cap (inverted) Trufast FM-90 Base Sheet Fasteners 7-inch o.c. at the min. 4-inch side laps and 7-inch o.c. at two, equally spaced, staggered center rows (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP- TA -45.0 LWC-97 Min. 22 ga., Type BV, Grade 33 steel, 5 ft span or structural concrete None Min. 200 psi, min 2- inch Elastizell. None Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet, Flintlastic Poly SMS Base Sheet or Flintglas MS Cap (inverted) Trufast FM-90 Base Sheet Fasteners or Trufast Twin Loc-Nail Assembled Fasteners (1.8 inch) 7-inch o.c. at the 4-inch lap and 7- inch o.c. in two (2), equally spaced, staggered center rows (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP- TA -45.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R29 for FL2533-R28 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 29: 04/14/2022 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 55 of 70 TABLE 4E: LIGHTWEIGHT CONCRETE DECKS OVER STEEL OR STRUCTURAL CONCRETE DECK – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE E-2: MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Lightweight Concrete (Note 14) Base Sheet Roof Cover (Note 15) MDP (psf) Deck Treatment LWC Surface Treatment Type Fasteners Attach Base Ply Cap Ply LWC-98 Min. 22 ga., Type BV, Grade 33 steel, 5 ft span or structural concrete None Min. 200 psi, min 2- inch Elastizell. None Flintlastic APP Base T Trufast FM-90 Base Sheet Fasteners 7-inch o.c. at the 4-inch lap and 7- inch o.c. in two (2), equally spaced, staggered center rows (Optional) APP-TA APP-TA -45.0 COLD APPLIED SYSTEMS: LWC-99 Min. 22 ga., Type BV, Grade 33 steel, 5 ft span or structural concrete None Min. 350 psi, min 2- inch Range II Elastizell with Zell-Crete Fibers. None Flintlastic Base 20, Flintlastic Poly SMS Base Sheet Trufast FM-90 Base Sheet Fasteners 7-inch o.c. at the 4-inch lap and 7- inch o.c. in two (2), equally spaced, staggered center rows (Optional) BP-CA2 or SBS-CA2 SBS-CA2 -45.0 LWC-100 Min. 22 ga., Type BV, Grade 33 steel, 5 ft span None Min. 350 psi, min 2- inch Range II Elastizell with Zell-Crete Fibers. None Glasbase Base Sheet, Flintlastic Poly SMS Base Sheet Trufast FM-90 Base Sheet Fasteners 7-inch o.c. at the 4-inch lap and 7- inch o.c. in two (2), equally spaced, staggered center rows (Optional) BP-CA3 or SBS-CA3 SBS-CA3 -52.5 LWC-101 Structural concrete None Min. 350 psi, min 2- inch Range II Elastizell with Zell-Crete Fibers. None Glasbase Base Sheet, Flintlastic Poly SMS Base Sheet Trufast FM-90 Base Sheet Fasteners 7-inch o.c. at the 4-inch lap and 7- inch o.c. in two (2), equally spaced, staggered center rows (Optional) BP-CA3 or SBS-CA3 SBS-CA3 -60.0 MEARLCRETE (FL13492): CONVENTIONAL SYSTEMS: LWC-102 Min. 22 ga., Type BV, Grade 33 steel, 5 ft span or structural concrete None Min. 250 psi, min 2- inch Mearlcrete. None Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet, Flintlastic Poly SMS Base Sheet or Flintglas MS Cap (inverted) OMG CR Base Ply Fasteners (1.7) 7-inch o.c. at the 4-inch lap and 7- inch o.c. in two (2), equally spaced, staggered center rows (Optional) BP-AA or SBS-AA SBS-AA or APP- TA -45.0 LWC-103 Min. 22 ga., Type BV, Grade 33 steel, 5 ft span or structural concrete None Min. 250 psi, min 2- inch Mearlcrete. None Flintlastic Poly SMS Base Sheet OMG CR Base Ply Fasteners (1.7) 7-inch o.c. at the 4-inch lap and 7- inch o.c. in two (2), equally spaced, staggered center rows (Optional) BP-AA or SBS-AA SBS-AA or APP- TA -52.5 LWC-104 Min. 22 ga., Type BV, Grade 33 steel, 5 ft span or structural concrete None Min. 300 psi, min 2- inch Mearlcrete. None Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet, Flintlastic Poly SMS Base Sheet or Flintglas MS Cap (inverted) OMG CR Base Ply Fasteners (1.7) 7-inch o.c. at the 4-inch lap and 7- inch o.c. in two (2), equally spaced, staggered center rows (Optional) BP-AA or SBS-AA SBS-AA or APP- TA -52.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R29 for FL2533-R28 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 29: 04/14/2022 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 56 of 70 TABLE 4F: LIGHTWEIGHT CONCRETE DECKS – REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE E: MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Lightweight Concrete (Note 14) Base Sheet Roof Cover (Note 15) MDP (psf) Type Surfacing Base Fasteners Spacing Base Ply Cap Ply PRE-EXISTENT CELLULAR LWC: LWC-105 Min. 22 ga., Type BV, Grade 40 steel Min. 470 psi, Min. 2- inch, pre-existent cellular lightweight concrete For reroof (tear-off), repair LWC spalls with Celcore SBS (Sanded Bonding Surface) Flintlastic Ultra Poly SMS Base Sheet Trufast Versa Fasteners (min. 2.25”) & Plates, two (2) screws per plate at 180° from each other* 9-inch o.c. within the min. 5- inch wide, heat-welded side laps (Optional) SBS-TA or APP-TA APP-TA -75.0 Note: *Field withdrawal resistance testing (Note 11) shall yield minimum 322 lbf. Additional Versa-Fast Fasteners within each Versa-Fast Plate may be utilized to produce minimum withdrawal resistance. For recover installations, screws shall be of sufficient length for minimum 2.25” embedment into the existing LWC assembly. TABLE 4G: LIGHTWEIGHT CONCRETE DECKS – REROOF (TEAR-OFF) SYSTEM TYPE F: NON-INSULATED, BONDED ROOF COVER System No. Deck (Note 1) Lightweight Concrete (Note 14) Roof Cover (Note 15) MDP (psf) Type Surfacing Base Ply Cap Ply PRE-EXISTENT CELLULAR LWC: LWC-106 Min. 22 ga., Type BV, Grade 40 steel Min. 400 psi, Min. 2- inch, pre-existent cellular lightweight concrete Repair LWC spalls with Celcore SBS (Sanded Bonding Surface) Flintlastic Ultra Poly SMS Base Sheet applied in HB Fuller “Millennium Hurricane Force Membrane Adhesive HS”, ribbons max. 6-inch o.c. 3-inch wide side laps and 6-inch wide end laps are hot-air-welded, torch-welded or sealed with HB Fuller “Millennium Hurricane Force Lap and Flashing Adhesive” SBS-CA1 or SBS-CA4 -75.0 LWC-107 Min. 22 ga., Type BV, Grade 40 steel Min. 400 psi, Min. 2- inch, pre-existent cellular lightweight concrete Repair LWC spalls with Celcore SBS (Sanded Bonding Surface) Flintlastic Ultra Poly SMS Base Sheet applied in HB Fuller “Millennium Hurricane Force Membrane Adhesive HS”, ribbons max. 6-inch o.c. 3-inch wide side laps and 6-inch wide end laps are hot-air-welded, torch-welded or sealed with HB Fuller “Millennium Hurricane Force Lap and Flashing Adhesive” Flintlastic FR-P, Flintlastic FR-P CoolStar, Flintlastic Premium FR-P, Flintlastic Premium FR-P CoolStar, or Flintlastic GMS, applied in HB Fuller “Millennium Hurricane Force Membrane Adhesive HS”, continuous ribbons maximum 6- inch o.c. 3-inch wide side laps and 6-inch wide end laps are hot-air-welded, torch-welded or sealed with HB Fuller “Millennium Hurricane Force Lap and Flashing Adhesive” -97.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R29 for FL2533-R28 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 29: 04/14/2022 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 57 of 70 TABLE 5A: CEMENTITIOUS WOOD FIBER DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER System No. Deck (Notes 1&12) Base Insulation Layer Top Insulation Layer Primer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply SELF-ADHERING SYSTEMS: CWF-1. Tectum Min. 1.5-inch ACFoam II or H- Shield M-OSFA (Optional) Additional layer(s) of base insulation and/or min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board. M-OSFA FlintPrime QD SBS-SA (Optional) SBS- SA SBS-SA -60.0 CWF-2. Tectum Min. 1.5-inch ACFoam II or H- Shield M-OSFA, 6- inch o.c. (Optional) Additional layer(s) of base insulation and/or min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board. M-OSFA, 6- inch o.c. FlintPrime QD SBS-SA (Optional) SBS- SA SBS-SA -90.0 CWF-3. Existing Tectum (re- roof only) Min. 1.5-inch ACFoam II, ENRGY 3 or Multi-Max FA3 OB500 Min. 0.25-inch DensDeck OB500 FlintPrime QD SBS-SA (Optional) SBS- SA SBS-SA -45.0* CWF-4. Existing Tectum (re- roof only) Min. 1.5-inch ACFoam II, ENRGY 3 or Multi-Max FA3 OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 None SBS-SA (Optional) SBS- SA SBS-SA -45.0* CWF-5. Tectum Min. 1-inch ENRGY 3, H-Shield or H-Shield CG or min. 1.5-inch Multi-Max FA3 or Ultra-Max Polyset BM or Polyset CRA Min. 0.25-inch DensDeck Polyset BM or Polyset CRA FlintPrime QD SBS-SA (Optional) SBS- SA SBS-SA -52.5 CWF-6. Tectum Min. 1-inch ENRGY 3, H-Shield or H-Shield CG or min. 1.5-inch Multi-Max FA3 or Ultra-Max Polyset BM or Polyset CRA Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Polyset BM or Polyset CRA None SBS-SA (Optional) SBS- SA SBS-SA -52.5 HYBRID SYSTEMS: CWF-7. Tectum Min. 1.5-inch ACFoam II or H- Shield M-OSFA (Optional) Additional layer(s) of base insulation and/or min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board. M-OSFA None SBS-SA-H (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -60.0 CWF-8. Tectum Min. 1.5-inch ACFoam II or H- Shield M-OSFA, 6- inch o.c. (Optional) Additional layer(s) of base insulation and/or min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board. M-OSFA, 6- inch o.c. None SBS-SA-H (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -90.0 CONVENTIONAL SYSTEMS: CWF-9. Tectum Min. 1.5-inch ACFoam II or H- Shield M-OSFA Optional additional layers of base insulation, followed by min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board M-OSFA None BP-AA, SBS- AA, SBS-TA or APP-TA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -60.0 CWF-10. Tectum Min. 1.5-inch ACFoam II or H- Shield M-OSFA, 6- inch o.c. Optional additional layers of base insulation, followed by min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board. M-OSFA, 6- inch o.c. None BP-AA, SBS- AA, SBS-TA or APP-TA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -90.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R29 for FL2533-R28 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 29: 04/14/2022 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 58 of 70 TABLE 5A: CEMENTITIOUS WOOD FIBER DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER System No. Deck (Notes 1&12) Base Insulation Layer Top Insulation Layer Primer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply CWF-11. Existing Tectum (re- roof only) Min. 1.5-inch ACFoam II, ENRGY 3 or Multi-Max FA3 OB500 Min. 0.5-inch Structodek High Density Fiberboard OB500 None BP-AA or SBS-AA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -45.0* CWF-12. Existing Tectum (re- roof only) Min. 1.5-inch ACFoam II, ENRGY 3 or Multi-Max FA3 OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board or DensDeck or DensDeck Prime OB500 None BP-AA, SBS- AA, SBS-TA or APP-TA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -45.0* CWF-13. Tectum Min. 1-inch ENRGY 3, H-Shield, or H-Shield CG, min. 1.3-inch ACFoam III or min. 1.5-inch Multi-Max FA3 or Ultra-Max Polyset BM or Polyset CRA Min. 0.5-inch Structodek High Density Fiberboard Polyset CRA None BP-AA or SBS-AA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -52.5 CWF-14. Tectum Min. 1-inch ENRGY 3, H-Shield or H-Shield CG or min. 1.5-inch Multi-Max FA3 or Ultra-Max Polyset BM or Polyset CRA Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board or DensDeck or DensDeck Prime Polyset BM or Polyset CRA None BP-AA, SBS- AA, SBS-TA or APP-TA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -52.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R29 for FL2533-R28 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 29: 04/14/2022 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 59 of 70 TABLE 5B: CEMENTITIOUS WOOF FIBER DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 15) MDP (psf) Type Fasteners (Note 11) Attach Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply HYBRID SYSTEMS: CWF-15. Tectum Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet or Flintglas MS Cap (inverted) Trufast Twin Loc-Nail Assembled Fastener (Field W/D > 80 lbf) 6-inch o.c. at the 4- inch lap and 10-inch o.c. in two (2), equally spaced, staggered center rows Min. 1.5-inch ACFoam II, ENRGY 3 or Multi-Max FA3 hot asphalt (Optional) Min. 0.25- inch SECUROCK Gypsum-Fiber Roof Board hot asphalt SBS-SA-H (Optional) SBS-AA, SBS-TA or APP-TA SBS-AA or APP-TA -60.0 CWF-16. Tectum Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet or Flintglas MS Cap (inverted) Trufast Twin Loc-Nail Assembled Fastener (Field W/D > 69 lbf) 7-inch o.c. at the 4- inch lap and 7-inch o.c. in two (2), equally spaced, staggered center rows Min. 1.5-inch ACFoam II, ENRGY 3 or Multi-Max FA3 hot asphalt (Optional) Min. 0.25- inch SECUROCK Gypsum-Fiber Roof Board hot asphalt SBS-SA-H (Optional) SBS-AA, SBS-TA or APP-TA SBS-AA or APP-TA -60.0 CONVENTIONAL SYSTEMS: CWF-17. Existing Tectum Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet or Flintglas MS Cap (inverted) Trufast Twin Loc-Nail Assembled Fastener (Field W/D > 80 lbf) 6-inch o.c. at the 4- inch lap and 10-inch o.c. in two (2), equally spaced, staggered center rows Min. 1.5-inch ACFoam II, ENRGY 3 or Multi-Max FA3 hot asphalt Min. 0.75-inch FescoBoard (homogeneous) or min. 0.5-inch Structodek High Density Fiberboard hot asphalt BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-AA or APP-TA -60.0 CWF-18. Existing Tectum Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet or Flintglas MS Cap (inverted) Trufast Twin Loc-Nail Assembled Fastener (Field W/D > 69 lbf) 7-inch o.c. at the 4- inch lap and 7-inch o.c. in two (2), equally spaced, staggered center rows Min. 1.5-inch ACFoam II, ENRGY 3 or Multi-Max FA3 hot asphalt Min. 0.75-inch FescoBoard (homogeneous) or min. 0.5-inch Structodek High Density Fiberboard hot asphalt BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-AA or APP-TA -60.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R29 for FL2533-R28 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 29: 04/14/2022 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 60 of 70 TABLE 5C: CEMENTITIOUS WOOD FIBER DECKS – REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer(s) Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Fasteners (Note 11) Attach Base Ply Ply Cap Ply CWF-19. Existing Tectum (Optional) One or more layers, any combination, loose laid Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation OMG Polymer GypTec with 3” GypTec Plate (Field W/D > 180 lbf) 1 per 2.0 ft2 BP-AA or SBS-AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA or APP-TA -45.0* CWF-20. Existing Tectum (Optional) One or more layers, any combination, loose laid Min. 0.25-inch DensDeck or DensDeck Prime OMG Polymer GypTec with 3” GypTec Plate (Field W/D > 160 lbf) 1 per 1.8 ft2 BP-AA, SBS-AA, SBS- TA or APP-TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA or APP-TA -45.0* CWF-21. Existing Tectum (Optional) One or more layers, any combination, loose laid Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation Trufast Twin Loc-Nail Assembled Fasteners (Field W/D > 180 lbf) 1 per 2.0 ft2 BP-AA or SBS-AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA or APP-TA -45.0* CWF-22. Existing Tectum (Optional) One or more layers, any combination, loose laid Min. 0.25-inch DensDeck or DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Trufast Twin Loc-Nail Assembled Fasteners (Field W/D > 180 lbf) 1 per 2.0 ft2 BP-AA, SBS-AA, SBS- TA or APP-TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA or APP-TA -45.0* TABLE 5D: CEMENTITOUS WOOD FIBER DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) OR REROOF SYSTEM TYPE E-2: MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Base Sheet Roof Cover (Note 15) MDP (psf) Base Fasteners (Note 11) Attach Base Ply Cap Ply SELF-ADHERING SYSTEMS: CWF-23. Tectum Flintlastic SA NailBase Trufast Twin Loc-Nail Assembled Fastener (Field W/D > 80 lbf) 6-inch o.c. at the 4-inch lap and 10-inch o.c. in two (2), equally spaced, staggered center rows SBS-SA SBS-SA -60.0 CWF-24. Tectum Flintlastic SA NailBase Trufast Twin Loc-Nail Assembled Fastener (Field W/D > 69 lbf) 7-inch o.c. at the 4-inch lap and 7-inch o.c. in two (2), equally spaced, staggered center rows SBS-SA SBS-SA -60.0 CONVENTIONAL SYSTEMS: CWF-25. Existing Tectum (reroof only) All Weather/Empire Base Sheet or Flintglas MS Cap (inverted) Trufast Insuldeck Loc-Nail Base Sheet Fastener (Field W/D > 53 lbf) 9-inch o.c. at the 4-inch lap and 12-inch o.c. in two (2), equally spaced, staggered center rows BP-AA or SBS-AA SBS-AA -30.0* CWF-26. Existing Tectum (reroof only) All Weather/Empire Base Sheet or Flintglas MS Cap (inverted) Trufast Insuldeck Loc-Nail Base Sheet Fastener (Field W/D > 55 lbf) 7½-inch o.c. at the 4-inch lap and 7½-inch o.c. in two (2), equally spaced, staggered center rows BP-AA or SBS-AA SBS-AA -45.0* CWF-27. Tectum Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet or Flintglas MS Cap (inverted) Trufast Twin Loc-Nail Assembled Fastener (Field W/D > 80 lbf) 6-inch o.c. at the 4-inch lap and 10-inch o.c. in two (2), equally spaced, staggered center rows BP-AA or SBS-AA SBS-AA or APP- TA -60.0 CWF-28. Tectum Glasbase Base Sheet, Flintlastic Base 20 or All Weather/Empire Base Sheet or Flintglas MS Cap (inverted) Trufast Twin Loc-Nail Assembled Fastener (Field W/D > 77 lbf) 7-inch o.c. at the 4-inch lap and 7-inch o.c. in two (2), equally spaced, staggered center rows BP-AA or SBS-AA SBS-AA or APP- TA -67.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R29 for FL2533-R28 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 29: 04/14/2022 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 61 of 70 TABLE 6A: GYPSUM DECKS – REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER System No. Deck (Notes 1 & 12) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply SELF-ADHERING SYSTEMS: G-1. Existing sound gypsum or gypsum plank Min. 1.5-inch ACFoam II, ACFoam III, ENRGY 3, H-Shield or H-Shield CG M-OSFA Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board M-OSFA SBS-SA (Optional) SBS-SA SBS-SA -172.5 G-2. Existing sound gypsum or gypsum plank Min. 1.5-inch ACFoam II, ENRGY 3 or Multi-Max FA3 M-OSFA Min. 0.25-inch DensDeck primed with FlintPrime QD M-OSFA SBS-SA (Optional) SBS-SA SBS-SA -192.5 G-3. Existing sound gypsum or gypsum plank One or more layer(s), min. 1.5-inch ACFoam II, ACFoam III, H-Shield or H- Shield CG M-PG1 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board M-PG1 SBS-SA (Optional) SBS-SA SBS-SA -172.5 G-4. Existing sound gypsum or gypsum plank Min. 1.5-inch ACFoam II or ENRGY 3 OB500 Min. 0.25-inch DensDeck primed with FlintPrime QD OB500 SBS-SA (Optional) SBS-SA SBS-SA -135.0 G-5. Existing sound gypsum or gypsum plank One or more layer(s), min. 1.5-inch ACFoam II, ACFoam III, H-Shield or H- Shield CG OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 SBS-SA (Optional) SBS-SA SBS-SA -172.5 G-6. Existing sound gypsum or gypsum plank One or more layer(s), min. 1.5-inch ACFoam II, ACFoam III, H-Shield or H- Shield CG Polyset BM Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Polyset BM SBS-SA (Optional) SBS-SA SBS-SA -172.5 G-7. Existing sound gypsum or gypsum plank One or more layer(s), min. 1-inch H- Shield or ENRGY 3, min. 1.3-inch ACFoam III or min. 1.5-inch ACFoam II, Multi-Max FA3 or Ultra-Max Polyset CRA Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Polyset CRA SBS-SA (Optional) SBS-SA SBS-SA -172.5 G-8. Existing sound gypsum or gypsum plank min. 1-inch H-Shield or ENRGY 3, min. 1.3-inch ACFoam III or min. 1.5-inch ACFoam II, Multi-Max FA3 or Ultra- Max Polyset CRA Min. 0.25-inch DensDeck primed with FlintPrime QD Polyset CRA SBS-SA (Optional) SBS-SA SBS-SA -192.5 HYBRID SYSTEMS: G-9. Existing sound gypsum or gypsum plank One or more layer(s), min. 1.5-inch ACFoam II, ACFoam III, H-Shield or H- Shield CG M-OSFA, M- PG1, OB500, Polyset BM, Polyset CRA (Optional) Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board M-OSFA, M- PG1, OB500, Polyset BM, Polyset CRA SBS-SA-H (Optional) SBS-AA, SBS-TA or APP-TA SBS-AA or APP-TA -187.5 CONVENTIONAL SYSTEMS: G-10. Existing sound gypsum or gypsum plank Min. 1.5-inch ACFoam II, ENRGY 3 or H-Shield M-OSFA Min. 0.5-inch Structodek High Density Fiberboard M-OSFA BP-AA or SBS- AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA or APP-TA -127.5 G-11. Existing sound gypsum or gypsum plank One or more layer(s), min. 1.5-inch ACFoam II, ACFoam III, H-Shield or H- Shield CG M-OSFA Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board M-OSFA BP-AA or SBS- AA, SBS-TA or APP-TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA or APP-TA -187.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R29 for FL2533-R28 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 29: 04/14/2022 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 62 of 70 TABLE 6A: GYPSUM DECKS – REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER System No. Deck (Notes 1 & 12) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply G-12. Existing sound gypsum or gypsum plank Min. 1.5-inch ACFoam II, ENRGY 3 or H-Shield M-OSFA Min. 0.25-inch DensDeck M-OSFA BP-AA or SBS- AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA or APP-TA -232.5 G-13. Existing sound gypsum or gypsum plank Min. 2-inch ACFoam II, ENRGY 3 or H- Shield M-OSFA Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board M-OSFA BP-AA or SBS- AA, SBS-TA or APP-TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA or APP-TA -202.5 G-14. Existing sound gypsum or gypsum plank One or more layer(s), min. 1.5-inch ACFoam II, ACFoam III, H-Shield or H- Shield CG M-PG1 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board M-PG1 BP-AA or SBS- AA, SBS-TA or APP-TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA or APP-TA -187.5 G-15. Existing sound gypsum or gypsum plank Min. 1.5-inch ACFoam II, ENRGY 3 or H-Shield OB500 Min. 0.5-inch Structodek High Density Fiberboard OB500 BP-AA or SBS- AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA or APP-TA -120.0 G-16. Existing sound gypsum or gypsum plank Min. 1.5-inch ACFoam II, ENRGY 3 or H-Shield OB500 Min. 0.25-inch DensDeck, DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 BP-AA, SBS- AA, SBS-TA or APP-TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA or APP-TA -135.0 G-17. Existing sound gypsum or gypsum plank One or more layer(s), min. 1.5-inch ACFoam II, ACFoam III, H-Shield or H- Shield CG OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 BP-AA, SBS- AA, SBS-TA or APP-TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA or APP-TA -187.5 G-18. Existing sound gypsum or gypsum plank One or more layer(s), min. 1.5-inch ACFoam II, ACFoam III, H-Shield or H- Shield CG Polyset BM Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Polyset BM BP-AA, SBS- AA, SBS-TA or APP-TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA or APP-TA -187.5 G-19. Existing sound gypsum or gypsum plank Min. 1-inch ENRGY 3, H-Shield or H- Shield CG or min. 1.5-inch Multi-Max FA3 or Ultra-Max Polyset CRA Min. 0.5-inch Structodek High Density Fiberboard Polyset CRA BP-AA or SBS- AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA or APP-TA -180.0 G-20. Existing sound gypsum or gypsum plank One or more layer(s), min. 1.5-inch ACFoam II, ACFoam III, H-Shield or H- Shield CG Polyset CRA Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Polyset CRA BP-AA, SBS- AA, SBS-TA or APP-TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA or APP-TA -187.5 G-21. Existing sound gypsum or gypsum plank Min. 1-inch ENRGY 3, H-Shield or H- Shield CG or min. 1.5-inch Multi-Max FA3 or Ultra-Max Polyset CRA Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Polyset CRA BP-AA or SBS- AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA or APP-TA -225.0 G-22. Existing sound gypsum or gypsum plank Min. 1-inch ENRGY 3, H-Shield or H- Shield CG or min. 1.5-inch Multi-Max FA3 or Ultra-Max Polyset CRA Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Polyset CRA SBS-TA or APP-TA (Optional) SBS-TA or APP-TA APP-TA -232.5 G-23. Existing sound gypsum or gypsum plank Min. 1-inch ENRGY 3, H-Shield or H- Shield CG or min. 1.5-inch Multi-Max FA3 or Ultra-Max Polyset CRA Min. 0.25-inch DensDeck Polyset CRA BP-AA or SBS- AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA or APP-TA -240.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R29 for FL2533-R28 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 29: 04/14/2022 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 63 of 70 TABLE 6B: GYPSUM DECKS – REROOF (TEAR-OFF) SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 15) MDP (psf) Type Fasteners (Note 11) Attach Type Attach Type Attach Base Ply Ply Cap Ply HYBRID SYSTEMS: G-24. Existing sound gypsum or gypsum plank Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet or Flintglas MS Cap (inverted) Trufast Twin Loc- Nail Assembled Fastener (Field W/D > 80 lbf) 6-inch o.c. at the 4-inch lap and 10- inch o.c. in two (2), equally spaced, staggered center rows Min. 1.5-inch ACFoam II, ENRGY 3 or Multi-Max FA3 hot asphalt None N/A SBS-SA- H (Optional) SBS-AA, SBS-TA or APP-TA SBS-AA or APP-TA -60.0 G-25. Existing sound gypsum or gypsum plank Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet or Flintglas MS Cap (inverted) Trufast Twin Loc- Nail Assembled Fastener (Field W/D > 69 lbf) 7-inch o.c. at the 4-inch lap and 7- inch o.c. in two (2), equally spaced, staggered center rows Min. 1.5-inch ACFoam II, ENRGY 3 or Multi-Max FA3 hot asphalt None N/A SBS-SA- H (Optional) SBS-AA, SBS-TA or APP-TA SBS-AA or APP-TA -60.0 CONVENTIONAL SYSTEMS: G-26. Existing sound gypsum or gypsum plank All Weather/Empire Base Sheet or Flintglas MS Cap (inverted) Trufast FM-75 or FM-90 Base Sheet Fastener or Twin Loc-Nail Assembled Fastener (Field W/D > 100 lbf) 9-inch o.c. at the 4-inch lap and 18- inch o.c. in two (2), equally spaced, staggered center rows (Optional) Min. 1.5- inch ACFoam II, ENRGY 3 or Multi- Max FA3 hot asphalt Min. 0.75-inch FescoBoard (homogeneous) or min. 0.5-inch Structodek High Density Fiberboard hot asphalt BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-AA or APP-TA -45.0* G-27. Existing sound gypsum or gypsum plank Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet or Flintglas MS Cap (inverted) Trufast Twin Loc- Nail Assembled Fastener (Field W/D > 80 lbf) 6-inch o.c. at the 4-inch lap and 10- inch o.c. in two (2), equally spaced, staggered center rows Min. 1.5-inch ACFoam II, ENRGY 3 or Multi-Max FA3 hot asphalt Min. 0.75-inch FescoBoard (homogeneous) or min. 0.5-inch Structodek High Density Fiberboard hot asphalt BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-AA or APP-TA -60.0 G-28. Existing sound gypsum or gypsum plank Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet or Flintglas MS Cap (inverted) Trufast Twin Loc- Nail Assembled Fastener (Field W/D > 69 lbf) 7-inch o.c. at the 4-inch lap and 7- inch o.c. in two (2), equally spaced, staggered center rows Min. 1.5-inch ACFoam II, ENRGY 3 or Multi-Max FA3 hot asphalt Min. 0.75-inch FescoBoard (homogeneous) or min. 0.5-inch Structodek High Density Fiberboard hot asphalt BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-AA or APP-TA -60.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R29 for FL2533-R28 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 29: 04/14/2022 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 64 of 70 TABLE 6C: GYPSUM DECKS – REROOF (TEAR-OFF) SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer(s) Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Fasteners (Note 11) Attach Base Ply Ply Cap Ply G-29. Existing sound gypsum or gypsum plank (Optional) One or more layers, any combination, loose laid Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation OMG Polymer GypTec with 3” GypTec Plate (Field W/D > 180 lbf) 1 per 2.0 ft2 BP-AA or SBS- AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA or APP-TA -45.0* G-30. Existing sound gypsum or gypsum plank (Optional) One or more layers, any combination, loose laid Min. 0.25-inch DensDeck or DensDeck Prime OMG Polymer GypTec with 3” GypTec Plate (Field W/D > 160 lbf) 1 per 1.8 ft2 BP-AA, SBS- AA, SBS-TA or APP-TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA or APP-TA -45.0* G-31. Existing sound gypsum or gypsum plank (Optional) One or more layers, any combination, loose laid Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation Trufast Twin Loc-Nail Assembled Fasteners (Field W/D > 180 lbf) 1 per 2.0 ft2 BP-AA or SBS- AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA or APP-TA -45.0* G-32. Existing sound gypsum or gypsum plank (Optional) One or more layers, any combination, loose laid Min. 0.25-inch DensDeck or DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Trufast Twin Loc-Nail Assembled Fasteners (Field W/D > 180 lbf) 1 per 2.0 ft2 BP-AA, SBS- AA, SBS-TA or APP-TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA or APP-TA -45.0* TABLE 6D: GYPSUM DECKS – REROOF (TEAR-OFF) SYSTEM TYPE E-2: MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Base Sheet Roof Cover (Note 15) MDP (psf) Base Fasteners (Note 11) Attach Base Ply Cap Ply SELF-ADHERING SYSTEMS: G-33. Existing sound gypsum or gypsum plank Flintlastic SA NailBase Trufast Twin Loc-Nail Assembled Fastener (Field W/D > 80 lbf) 6-inch o.c. at the 4-inch lap and 10-inch o.c. in two (2), equally spaced, staggered center rows SBS-SA SBS-SA -60.0 G-34. Existing sound gypsum or gypsum plank Flintlastic SA NailBase Trufast Twin Loc-Nail Assembled Fastener (Field W/D > 88 lbf) 9-inch o.c. at the 4-inch lap and 9-inch o.c. in two (2), equally spaced, staggered center rows SBS-SA SBS-SA -60.0 CONVENTIONAL SYSTEMS: G-35. Existing sound gypsum or gypsum plank All Weather/Empire Base Sheet or Flintglas MS Cap (inverted) Trufast FM-75 or FM-90 Base Sheet Fastener or Twin Loc-Nail Assembled Fastener (Field W/D > 100 lbf) 9-inch o.c. at the 4-inch lap and 18-inch o.c. in two (2), equally spaced, staggered center rows BP-AA or SBS- AA SBS-AA -45.0* G-36. Existing sound gypsum or gypsum plank Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet or Flintglas MS Cap (inverted) Trufast Twin Loc-Nail Assembled Fastener (Field W/D > 80 lbf) 6-inch o.c. at the 4-inch lap and 10-inch o.c. in two (2), equally spaced, staggered center rows BP-AA or SBS- AA SBS-AA or APP-TA -60.0 G-37. Existing sound gypsum or gypsum plank Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet or Flintglas MS Cap (inverted) Trufast Twin Loc-Nail Assembled Fastener (Field W/D > 100 lbf) 9-inch o.c. at the 4-inch lap and 9-inch o.c. in two (2), equally spaced, staggered center rows BP-AA or SBS- AA SBS-AA or APP-TA -67.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R29 for FL2533-R28 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 29: 04/14/2022 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 65 of 70 TABLE 7A: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER A The reported MDP documents the allowable maximum design pressure of the new insulation and roof cover when installed atop the substrate, irrespective of the deck type (See Note 1) or performance of the substrate (See Note 12). The deck and substrate shall be capable of resisting the project design pressure requirements, not to exceed the noted MDP, to the satisfaction of the Authority Having Jurisdiction. System No. Substrate (Notes 1 & 12) Base Insulation Layer Top Insulation Layer Primer Roof Cover (Note 15) MDP (psf)A Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply SELF-ADHERING SYSTEMS: R-1 Existing fully bonded BUR or modified bitumen roof cover (Optional) Min. 1.5-inch ACFoam II, ENRGY 3, H- Shield or Multi-Max FA3 hot asphalt Min. 0.25-inch DensDeck hot asphalt FlintPrime QD SBS-SA (Optional) SBS-SA SBS-SA -105.0 R-2 Existing fully bonded BUR or modified bitumen roof cover (Optional) Min. 1.5-inch ACFoam II, ENRGY 3, H- Shield or Multi-Max FA3 hot asphalt Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board hot asphalt None SBS-SA (Optional) SBS-SA SBS-SA -105.0 R-3 Existing fully-bonded smooth- or granule- surface asphalt BUR or SBS modified bitumen or granule-surface APP modified bitumen (Optional) Min. 1.5-inch ACFoam II or H-Shield M-OSFA or M- PG1 Min. 0.5-inch ACFoam-HD Coverboard or H-Shield HD M-OSFA or M- PG1 FlintPrime QD SBS-SA (Optional) SBS-SA SBS-SA -97.5 R-4 Existing fully-bonded smooth- or granule- surface asphalt BUR or SBS modified bitumen or granule-surface APP modified bitumen (Optional) Min. 1.5-inch ACFoam II, ENRGY 3 or H- Shield M-OSFA or M- PG1 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board M-OSFA or M- PG1 None SBS-SA (Optional) SBS-SA SBS-SA -172.5 R-5 Existing fully-bonded smooth- or granule- surface asphalt BUR or SBS modified bitumen or granule-surface APP modified bitumen (Optional) Min. 1.5-inch ACFoam II, ENRGY 3 or Multi-Max FA3 M-OSFA or M- PG1 Min. 0.25-inch DensDeck M-OSFA or M- PG1 FlintPrime QD SBS-SA (Optional) SBS-SA SBS-SA -192.5 R-6 Existing fully-bonded smooth- or granule- surface asphalt BUR or SBS modified bitumen or granule-surface APP modified bitumen (Optional) Min. 1.5-inch ACFoam II or H-Shield M-OSFA or M- PG1, 6-inch o.c. Min. 0.5-inch ACFoam-HD Coverboard or H-Shield HD M-OSFA or M- PG1, 6-inch o.c. FlintPrime QD SBS-SA (Optional) SBS-SA SBS-SA -315.0 R-7 Existing fully-bonded smooth- or granule- surface asphalt BUR or SBS modified bitumen or granule-surface APP modified bitumen (Optional) Min. 1.5-inch ACFoam II or H-Shield M-OSFA or M- PG1, 6-inch o.c. Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board M-OSFA or M- PG1, 6-inch o.c. FlintPrime QD SBS-SA (Optional) SBS-SA SBS-SA -315.0 R-8 Existing fully bonded BUR or modified bitumen roof cover (Optional) Min. 1.5-inch ACFoam II or ENRGY 3 OB500 Min. 0.25-inch DensDeck OB500 FlintPrime QD SBS-SA (Optional) SBS-SA SBS-SA -120.0 R-9 Existing fully bonded BUR or modified bitumen roof cover (Optional) Min. 1.5-inch ACFoam II or ENRGY 3 OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 None SBS-SA (Optional) SBS-SA SBS-SA -120.0 R-10 Existing fully-bonded smooth- or granule- surface asphalt BUR or granule-surface modified bitumen (Optional) Min. 1.5-inch ACFoam II or H-Shield Polyset BM Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Polyset BM None SBS-SA (Optional) SBS-SA SBS-SA -172.5 R-11 Existing fully-bonded smooth- or granule- surface asphalt BUR or granule-surface modified bitumen (Optional) Min. 1.5-inch ACFoam II or H-Shield Polyset BM Min. 0.25-inch DensDeck Polyset BM FlintPrime QD SBS-SA (Optional) SBS-SA SBS-SA -192.5 R-12 Existing fully-bonded smooth- or granule- surface asphalt BUR or SBS modified bitumen or granule-surface APP modified bitumen (Optional) Min. 1.5-inch ACFoam II or H-Shield Polyset CRA Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Polyset CRA None SBS-SA (Optional) SBS-SA SBS-SA -172.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R29 for FL2533-R28 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 29: 04/14/2022 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 66 of 70 TABLE 7A: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER A The reported MDP documents the allowable maximum design pressure of the new insulation and roof cover when installed atop the substrate, irrespective of the deck type (See Note 1) or performance of the substrate (See Note 12). The deck and substrate shall be capable of resisting the project design pressure requirements, not to exceed the noted MDP, to the satisfaction of the Authority Having Jurisdiction. System No. Substrate (Notes 1 & 12) Base Insulation Layer Top Insulation Layer Primer Roof Cover (Note 15) MDP (psf)A Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply R-13 Existing fully-bonded smooth- or granule- surface asphalt BUR or SBS modified bitumen or granule-surface APP modified bitumen (Optional) Min. 1.5-inch ACFoam II or H-Shield Polyset CRA Min. 0.25-inch DensDeck Polyset CRA FlintPrime QD SBS-SA (Optional) SBS-SA SBS-SA -192.5 HYBRID SYSTEMS: R-14 Existing fully bonded BUR or modified bitumen roof cover (Optional) Min. 1.5-inch ACFoam II, ENRGY 3, H- Shield or Multi-Max FA3 hot asphalt Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board hot asphalt None SBS-SA-H (Optional) SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -105.0 R-15 Existing fully-bonded smooth- or granule- surface asphalt BUR or SBS modified bitumen or granule-surface APP modified bitumen (Optional) Min. 1.5-inch ACFoam II or H-Shield M-OSFA or M- PG1 Min. 0.5-inch ACFoam-HD CoverBoard or H-Shield HD M-OSFA or M- PG1 None SBS-SA-H (Optional) SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -97.5 R-16 Existing fully-bonded smooth- or granule- surface asphalt BUR or SBS modified bitumen or granule-surface APP modified bitumen (Optional) Min. 1.5-inch ACFoam II or H-Shield M-OSFA or M- PG1 (Optional) Additional layer(s) base insulation M-OSFA or M- PG1 None SBS-SA-H (Optional) SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -210.0 R-17 Existing fully-bonded smooth- or granule- surface asphalt BUR or SBS modified bitumen or granule-surface APP modified bitumen (Optional) Min. 1.5-inch ACFoam II or H-Shield M-OSFA or M- PG1 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board M-OSFA or M- PG1 None SBS-SA-H (Optional) SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -210.0 R-18 Existing fully-bonded smooth- or granule- surface asphalt BUR or SBS modified bitumen or granule-surface APP modified bitumen (Optional) Min. 1.5-inch ACFoam II or H-Shield M-OSFA or M- PG1, 6-inch o.c. Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board or min. 0.5-inch ACFoam-HD CoverBoard or H-Shield HD M-OSFA or M- PG1, 6-inch o.c. None SBS-SA-H (Optional) SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -315.0 R-19 Existing fully bonded, smooth- or granule- surface BUR or modified bitumen (Optional) Min. 1.5-inch ACFoam II or ENRGY 3 OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 None SBS-SA-H (Optional) SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -120.0 R-20 Existing fully-bonded smooth- or granule- surface asphalt BUR or granule-surface modified bitumen (Optional) Min. 1.5-inch ACFoam II or H-Shield Polyset BM (Optional) Additional layer(s) base insulation Polyset BM None SBS-SA-H (Optional) SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -195.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R29 for FL2533-R28 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 29: 04/14/2022 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 67 of 70 TABLE 7A: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER A The reported MDP documents the allowable maximum design pressure of the new insulation and roof cover when installed atop the substrate, irrespective of the deck type (See Note 1) or performance of the substrate (See Note 12). The deck and substrate shall be capable of resisting the project design pressure requirements, not to exceed the noted MDP, to the satisfaction of the Authority Having Jurisdiction. System No. Substrate (Notes 1 & 12) Base Insulation Layer Top Insulation Layer Primer Roof Cover (Note 15) MDP (psf)A Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply R-21 Existing fully-bonded smooth- or granule- surface asphalt BUR or granule-surface modified bitumen (Optional0 Min. 1.5-inch ACFoam II or H-Shield Polyset BM Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Polyset BM None SBS-SA-H (Optional) SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -195.0 R-22 Existing fully-bonded smooth- or granule- surface asphalt BUR or SBS modified bitumen or granule-surface APP modified bitumen Min. 1.5-inch ACFoam II or H-Shield Polyset CRA (Optional) Additional layer(s) base insulation Polyset CRA None SBS-SA-H (Optional) SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -222.5 R-23 Existing fully-bonded smooth- or granule- surface asphalt BUR or SBS modified bitumen or granule-surface APP modified bitumen (Optional) Min. 1.5-inch ACFoam II or H-Shield Polyset CRA Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Polyset CRA None SBS-SA-H (Optional) SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -217.5 CONVENTIONAL SYSTEMS: R-24 Existing fully bonded BUR or modified bitumen roof cover (Optional) Min. 1.5-inch ACFoam II, ENRGY 3, H- Shield or Multi-Max FA3 hot asphalt Min. 0.5-inch Structodek High Density Fiberboard, Min. 0.75-inch FescoBoard (homogeneous) or Min. 0.5- inch DuraBoard (homogeneous) hot asphalt None BP-AA or SBS-AA (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP-TA -105.0 R-25 Existing fully bonded BUR or modified bitumen roof cover (Optional) Min. 1.5-inch ACFoam II, ENRGY 3, H- Shield or Multi-Max FA3 hot asphalt 0.25-inch DensDeck, DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board hot asphalt None BP-AA, SBS-AA, SBS-TA or APP-TA (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP-TA -105.0 R-26 Existing fully-bonded smooth- or granule- surface asphalt BUR or SBS modified bitumen or granule-surface APP modified bitumen (Optional) Min. 1.5-inch ACFoam II, ENRGY 3 or H- Shield M-OSFA or M- PG1 Min. 0.5-inch Structodek High Density Fiberboard M-OSFA or M- PG1 None BP-AA or SBS-AA (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP-TA -165.0 R-27 Existing fully-bonded smooth- or granule- surface asphalt BUR or SBS modified bitumen or granule-surface APP modified bitumen (Optional) Min. 1.5-inch ACFoam II, ENRGY 3 or H- Shield M-OSFA or M- PG1 Min. 0.25-inch DensDeck M-OSFA or M- PG1 None BP-AA or SBS-AA (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP-TA -210.0 R-28 Existing fully-bonded smooth- or granule- surface asphalt BUR or SBS modified bitumen or granule-surface APP modified bitumen (Optional) Min. 1.5-inch ACFoam II or H-Shield M-OSFA or M- PG1 Min. 0.25-inch DensDeck Prime M-OSFA or M- PG1 None BP-AA, SBS-AA, SBS-TA (Optional) BP-AA, SBS- AA or SBS- TA SBS-AA -210.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R29 for FL2533-R28 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 29: 04/14/2022 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 68 of 70 TABLE 7A: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER A The reported MDP documents the allowable maximum design pressure of the new insulation and roof cover when installed atop the substrate, irrespective of the deck type (See Note 1) or performance of the substrate (See Note 12). The deck and substrate shall be capable of resisting the project design pressure requirements, not to exceed the noted MDP, to the satisfaction of the Authority Having Jurisdiction. System No. Substrate (Notes 1 & 12) Base Insulation Layer Top Insulation Layer Primer Roof Cover (Note 15) MDP (psf)A Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply R-29 Existing fully-bonded smooth- or granule- surface asphalt BUR or SBS modified bitumen or granule-surface APP modified bitumen (Optional) Min. 2-inch ACFoam II, ENRGY 3 or H- Shield M-OSFA or M- PG1 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board M-OSFA or M- PG1 None BP-AA, SBS-AA, SBS-TA or APP-TA (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP-TA -210.0 R-30 Existing fully-bonded smooth- or granule- surface asphalt BUR or SBS modified bitumen or granule-surface APP modified bitumen (Optional) Min. 1.5-inch ACFoam II or H-Shield M-OSFA or M- PG1, 6-inch o.c. Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board M-OSFA or M- PG1, 6-inch o.c. None SBS-AA or SBS-TA (Optional) SBS-AA or SBS-TA SBS-AA -315.0 R-31 Existing fully-bonded smooth- or granule- surface asphalt BUR or SBS modified bitumen or granule-surface APP modified bitumen (Optional) Min. 1.5-inch ACFoam II or H-Shield M-OSFA or M- PG1, 6-inch o.c. Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board M-OSFA or M- PG1, 6-inch o.c. None Flintlastic STA or Flintlastic STA Plus (Optional) APP-TA APP-TA -315.0 R-32 Existing fully bonded BUR or modified bitumen roof cover (Optional) Min. 1.5-inch ACFoam II, ENRGY 3 or H- Shield OB500 Min. 0.5-inch Structodek High Density Fiberboard OB500 None BP-AA or SBS-AA (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP-TA -120.0 R-33 Existing fully bonded BUR or modified bitumen roof cover (Optional) Min. 1.5-inch ACFoam II, ENRGY 3 or H- Shield OB500 Min. 0.25-inch DensDeck, DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 None BP-AA, SBS-AA, SBS-TA or APP-TA (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP-TA -120.0 R-34 Existing fully-bonded smooth- or granule- surface asphalt BUR or granule-surface modified bitumen (Optional) Min. 1.5-inch ACFoam II or H-Shield Polyset BM Min. 0.25-inch DensDeck Polyset BM None BP-AA or SBS-AA (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP-TA -195.0 R-35 Existing fully-bonded smooth- or granule- surface asphalt BUR or granule-surface modified bitumen (Optional) Min. 1.5-inch ACFoam II or H-Shield Polyset BM Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Polyset BM None BP-AA, SBS-AA, SBS-TA or APP-TA (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP-TA -195.0 R-36 Existing fully-bonded smooth- or granule- surface asphalt BUR or SBS modified bitumen or granule-surface APP modified bitumen Min. 1.5-inch ACFoam II or H-Shield Polyset CRA Min. 0.5-inch Structodek High Density Fiberboard Polyset CRA None BP-AA or SBS-AA (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP-TA -180.0 R-37 Existing fully-bonded smooth- or granule- surface asphalt BUR or SBS modified bitumen or granule-surface APP modified bitumen (Optional) Min. 1.5-inch ACFoam II or H-Shield Polyset CRA Min. 0.25-inch DensDeck Polyset CRA None BP-AA or SBS-AA (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP-TA -222.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R29 for FL2533-R28 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 29: 04/14/2022 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 69 of 70 TABLE 7A: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER A The reported MDP documents the allowable maximum design pressure of the new insulation and roof cover when installed atop the substrate, irrespective of the deck type (See Note 1) or performance of the substrate (See Note 12). The deck and substrate shall be capable of resisting the project design pressure requirements, not to exceed the noted MDP, to the satisfaction of the Authority Having Jurisdiction. System No. Substrate (Notes 1 & 12) Base Insulation Layer Top Insulation Layer Primer Roof Cover (Note 15) MDP (psf)A Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply R-38 Existing fully-bonded smooth- or granule- surface asphalt BUR or SBS modified bitumen or granule-surface APP modified bitumen (Optional) Min. 1.5-inch ACFoam II or H-Shield Polyset CRA Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Polyset CRA None BP-AA, SBS-AA, SBS-TA or APP-TA (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP-TA -222.5 COLD-APPLIED SYSTEMS: R-39 Existing fully-bonded smooth- or granule- surface asphalt BUR or SBS modified bitumen or granule-surface APP modified bitumen (Optional) Min. 1.5-inch ACFoam II or H-Shield M-OSFA or M- PG1 Min. 0.5-inch ACFoam-HD CoverBoard or H-Shield HD M-OSFA or M- PG1 None SBS-CA1 None SBS-CA1 -97.5 R-40 Existing fully-bonded smooth- or granule- surface asphalt BUR or SBS modified bitumen or granule-surface APP modified bitumen (Optional) Min. 1.5-inch ACFoam II or H-Shield M-OSFA or M- PG1 Min. 0.5-inch ACFoam-HD CoverBoard or H-Shield HD M-OSFA or M- PG1 None SBS-CA4 None SBS-CA4 -97.5 R-41 Existing fully-bonded smooth- or granule- surface asphalt BUR or SBS modified bitumen or granule-surface APP modified bitumen (Optional) Min. 0.5-inch ACFoam II or H-Shield M-OSFA or M- PG1 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board M-OSFA or M- PG1 None SBS-CA1 None SBS-CA1 -105.0 R-42 Existing fully-bonded smooth- or granule- surface asphalt BUR or SBS modified bitumen or granule-surface APP modified bitumen (Optional) Min. 0.5-inch ACFoam II or H-Shield M-OSFA or M- PG1 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board M-OSFA or M- PG1 None SBS-CA4 None SBS-CA4 -105.0 R-43 Existing fully bonded BUR or modified bitumen roof cover (Optional) Min. 0.5-inch ACFoam II or H-Shield OB500 Min. 1.5-inch ACFoam III or H-Shield CG OB500 None SBS-CA1 None SBS-CA1 -82.5 R-44 Existing fully bonded, smooth- or granule- surface BUR or modified bitumen (Optional) Min. 0.5-inch ACFoam II or H-Shield OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 None SBS-CA1 None SBS-CA1 -105.0 R-45 Existing fully bonded, smooth- or granule- surface BUR or modified bitumen (Optional) Min. 0.5-inch ACFoam II or H-Shield OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 None SBS-CA4 None SBS-CA4 -105.0 R-46 Existing fully-bonded smooth- or granule- surface asphalt BUR or granule-surface modified bitumen (Optional) Min. 0.5-inch ACFoam II or H-Shield Polyset BM Min. 1.5-inch ACFoam III Polyset BM None SBS-CA1 None SBS-CA1 -82.5 R-47 Existing fully-bonded smooth- or granule- surface asphalt BUR or granule-surface modified bitumen (Optional) Min. 0.5-inch ACFoam II or H-Shield Polyset BM Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Polyset BM None SBS-CA1 None SBS-CA1 -105.0 R-48 Existing fully-bonded smooth- or granule- surface asphalt BUR or granule-surface modified bitumen (Optional) Min. 0.5-inch ACFoam II or H-Shield Polyset BM Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Polyset BM None SBS-CA4 None SBS-CA4 -105.0 R-49 Existing fully-bonded smooth- or granule- surface asphalt BUR or SBS modified bitumen or granule-surface APP modified bitumen (Optional) Min. 0.5-inch ACFoam II or H-Shield Polyset CRA Min. 1.5-inch ACFoam III or H-Shield CG Polyset CRA None SBS-CA1 None SBS-CA1 -82.5 R-50 Existing fully-bonded smooth- or granule- surface asphalt BUR or SBS modified bitumen or granule-surface APP modified bitumen (Optional) Min. 0.5-inch ACFoam II or H-Shield Polyset CRA Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Polyset CRA None SBS-CA1 None SBS-CA1 -105.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R29 for FL2533-R28 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Revision 29: 04/14/2022 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 70 of 70 TABLE 7A: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER A The reported MDP documents the allowable maximum design pressure of the new insulation and roof cover when installed atop the substrate, irrespective of the deck type (See Note 1) or performance of the substrate (See Note 12). The deck and substrate shall be capable of resisting the project design pressure requirements, not to exceed the noted MDP, to the satisfaction of the Authority Having Jurisdiction. System No. Substrate (Notes 1 & 12) Base Insulation Layer Top Insulation Layer Primer Roof Cover (Note 15) MDP (psf)A Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply R-51 Existing fully-bonded smooth- or granule- surface asphalt BUR or SBS modified bitumen or granule-surface APP modified bitumen (Optional) Min. 0.5-inch ACFoam II or H-Shield Polyset CRA Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Polyset CRA None SBS-CA4 None SBS-CA4 -105.0 TABLE 7B: RECOVER APPLICATIONS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE F: NON-INSULATED, BONDED ROOF COVER A The reported MDP documents the allowable maximum design pressure of the new roof cover when installed atop the substrate, irrespective of the deck type (See Note 1) or performance of the substrate (See Note 12). The deck and substrate shall be capable of resisting the project design pressure requirements, not to exceed the noted MDP, to the satisfaction of the Authority Having Jurisdiction. System No. Substrate (Notes 1 & 12) Primer Roof Cover (Note 15) MDP (psf)A Base Ply Ply Cap Ply R-52 Existing fully bonded asphalt built-up roof (BUR) (Optional) FlintPrime QD SBS-CA1 None SBS-CA1 -187.5 ROOF22-0041 By Mike Jones at 4:10 pm, Jul 28, 2022REVIEWED FOR CODE COMPLIANCE Jordan Roofing, LLC To: City of Atlantic Beach Building Department From: Joshua Jordan Title: Owner 904-497-3167 Company: Jordan Roofing LLC Manager: Charlene Jordan 904-652-8103 I have attached the Building Permit Application for 132 Seminole Road, Atlantic Beach, FL 32233 RE#170598-0000. We will be doing a re- roof with product # FL2533.1 & FL2533R17. Please let me know if there is any additional information required. Thank you, Joshua Jordan ROOF22-0041 DESCRIPTION ACCOUNT QTY PAID PermitTRAK $212.69 ROOF22-0041 Address: 132 SEMINOLE RD APN: 170598 0000 $212.69 BLDG SUBSEQUENT PLAN REVIEW FEES $50.00 BLDG 2ND PLAN REVIEW FEE 455-0000-322-1006 0 $50.00 BUILDING $105.00 BUILDING PERMIT 455-0000-322-1000 0 $105.00 BUILDING PLAN REVIEW $52.50 BUILDING PLAN CHECK 455-0000-322-1001 0 $52.50 STATE SURCHARGES $5.19 STATE DBPR SURCHARGE 455-0000-208-0700 0 $3.11 STATE DCA SURCHARGE 455-0000-208-0600 0 $2.08 TOTAL FEES PAID BY RECEIPT: R20223 $212.69 Printed: Friday, July 29, 2022 8:57 AM Date Paid: Friday, July 29, 2022 Paid By: Jordan Roofing LLC Pay Method: CREDIT CARD 675826432 1 of 1 Cashier: TG Cash Register Receipt City of Atlantic Beach Receipt Number R20223 ~+; CENTRALSQUARE