Loading...
340 2nd Ave ACRS22-0166 Revised Man D (2) Wade Residence 7-26-22Job #: Performed for: Wade Residence 340 2nd Ave Atlantic Beach, FL Exclusively for the use of: Environmental Air Conditioning Scale: 1 : 91 Page 1 Right-Suite® Universal 2022 22.0.02 RSU17457 2022-Jul-25 12:12:21 ...evised) 340 2nd Ave, Atl Bch.rup N 1st Floor Library His Study Kitchen Mud Room Laundry Dining Pantry Pool Bath Great RoomFoyer Powder Owner BedOwner Bath His WIC Her WIC 63 cfm 89 cfm 63 cfm 48 cfm 43 cfm 69 cfm 48 cfm 64 cfm 48 cfm 34 cfm 84 cfm34 cfm 84 cfm 477 cfm 64 cfm Sup Riser 15 " 6 " 6 " Ret Riser 12 "Sup Riser 10 " 4 "6 " 4 " 4 " 6 " 10 " 67 cfm 4 " 66 cfm 6 " 26 cfm4 " 4 " 12 " 25 cfm 4 " 6 " 6 " 7 " 10 "6 " 11 " 12 " 9 " 6 " 10 " 4 " 4 " Ret Riser 14 "533 cfm By Toni Gindlesperger at 4:40 pm, Jul 26, 2022 2:53 pm, Aug 06, 2022 By Mike Jones at 2:53 pm, Aug 06, 2022 Job #: Performed for: Wade Residence 340 2nd Ave Atlantic Beach, FL Exclusively for the use of: Environmental Air Conditioning Scale: 1 : 91 Page 2 Right-Suite® Universal 2022 22.0.02 RSU17457 2022-Jul-25 12:12:21 ...evised) 340 2nd Ave, Atl Bch.rup N 2nd Floor Game Room Sewing Media Room WIC 4 Bed 4 Bath 4 Bed 3 Bath 3 WIC 3 Bed 2 WIC 2 Bath 2 Laundry 2 Hall 2 Room16 105 cfm 162 cfm 45 cfm 109 cfm 30 cfm 269 cfm105 cfm 8 cfm 125 cfm 25 cfm 105 cfm 141 cfm 19 cfm 93 cfm 16 cfm 90 cfm 90 cfm 5 cfm 66 cfm 22 cfm 303 cfm 97 cfm 10 " 8 " 8 " 4 " 7 " 4 " 8 "15 " 4 " 4 " 4 " 6 " 6 " 4 " 6 " 10 " 14 " 14 " 6 " 7 " 4 " 7 " 7 " 6 " 4 " Sup Riser 15 " Ret Riser 12 "Sup Riser 10 " 12 " 15 " 10 " 12 " 10 "Ret Riser 14 " 14 " 12 " 12 " By Toni Gindlesperger at 4:40 pm, Jul 26, 2022 2:54 pm, Aug 06, 2022 Bold/italic values have been manually overridden 2022-Jul-25 12:12:12 Right-Suite® Universal 2022 22.0.02 RSU17457 Page 1 ...de Residence (Revised) 340 2nd Ave, Atl Bch.rup Calc = MJ8 Front Door faces: N Job:Duct System Summary Date: 1st Floor By: Exclusively for the use of:, Environmental Air Conditioning Project Information Wade Residence, RevisedFor: 340 2nd Ave, Atlantic Beach, FL CoolingHeating External static pressure in H2O0.20in H2O0.20 Pressure losses in H2O0in H2O0 Available static pressure in H2O0.20in H2O0.20 Supply / return available pressure 0.139 / 0.061 in H2O in H2O0.139 / 0.061 Lowest friction rate in/100ft0.031in/100ft0.031 Actual air flow cfm1000cfm1000 Total effective length (TEL)ft651 Supply Branch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Eqv Name (Btuh)(cfm)(cfm)FR (in)(in)Matl Ln (ft)Ln (ft)Trunk st10365.039.0ShMt0x06.00.03463602326cDining-A st10365.039.1ShMt0x06.00.03463602326cDining-B st5295.060.0ShMt0x06.00.03944481723hFoyer st5290.050.0ShMt0x06.00.04144481723hFoyer-A st12395.046.8ShMt0x04.00.03264642386cHer WIC st6280.047.0ShMt0x06.00.04360642293hHis Study st12295.041.1ShMt0x04.00.04141431541hHis WIC st5285.039.0ShMt0x06.00.04360662371hKitchen st9225.045.5ShMt0x06.00.05189873329cLaundry srs1155.046.3ShMt0x04.00.06967672505cLibrary st9285.036.5ShMt0x04.00.0432625959cMud Room st12385.054.3ShMt0x04.00.03234331270cOwner Bath st12395.051.7ShMt0x04.00.03134331270cOwner Bath-A st12390.063.2ShMt0x06.00.03184813115cOwner Bed st12380.061.5ShMt0x06.00.03284813115cOwner Bed-A st9295.050.5ShMt0x04.00.0402524944cPantry st9290.055.5ShMt0x04.00.04048471800cPool Bath st5225.073.5ShMt0x04.00.04769692573cPowder 2:54 pm, Aug 06, 2022 Bold/italic values have been manually overridden 2022-Jul-25 12:12:12 Right-Suite® Universal 2022 22.0.02 RSU17457 Page 2 ...de Residence (Revised) 340 2nd Ave, Atl Bch.rup Calc = MJ8 Front Door faces: N Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm)(cfm)FR (fpm)(in)(in)Material Trunk srs1 Peak AVF 664 659 0.034 541 15.0 0x0 ShtMetl st11 st5 Peak AVF 230 218 0.039 422 10.0 0x0 ShtMetl st7 st7 Peak AVF 294 278 0.039 445 11.0 0x0 ShtMetl st4 st6 Peak AVF 64 60 0.043 324 6.0 0x0 ShtMetl st7 st4 Peak AVF 597 592 0.034 1095 10.0 0x0 ShtMetl srs1 st8 Peak AVF 303 314 0.034 400 12.0 0x0 ShtMetl st4 st12 Peak AVF 336 341 0.031 625 10.0 0x0 ShtMetl st1 st11 Peak AVF 664 659 0.034 541 15.0 0x0 ShtMetl st1 st1 Peak AVF 1000 1000 0.031 815 15.0 0x0 ShtMetl st9 Peak AVF 184 189 0.040 428 9.0 0x0 ShtMetl st8 st10 Peak AVF 119 125 0.034 468 7.0 0x0 ShtMetl st8 Return Branch Detail Table Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size (in)(cfm)(cfm)(ft)FR (fpm)(in)(in)Opening (in)Matl Trunk rb9 0x 5330 523 79.7 0.076 498 14.0 x0 0 ShMt rb2 0x 4670 477 198.0 0.031 608 12.0 x0 0 ShMt 2:54 pm, Aug 06, 2022 Bold/italic values have been manually overridden 2022-Jul-25 12:12:12 Right-Suite® Universal 2022 22.0.02 RSU17457 Page 3 ...de Residence (Revised) 340 2nd Ave, Atl Bch.rup Calc = MJ8 Front Door faces: N Job:Duct System Summary Date: 2nd Floor By: Exclusively for the use of:, Environmental Air Conditioning Project Information Wade Residence, RevisedFor: 340 2nd Ave, Atlantic Beach, FL CoolingHeating External static pressure in H2O0.20in H2O0.20 Pressure losses in H2O0in H2O0 Available static pressure in H2O0.20in H2O0.20 Supply / return available pressure 0.111 / 0.089 in H2O in H2O0.111 / 0.089 Lowest friction rate in/100ft0.044in/100ft0.044 Actual air flow cfm1000cfm1000 Total effective length (TEL)ft453 Supply Branch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Eqv Name (Btuh)(cfm)(cfm)FR (in)(in)Matl Ln (ft)Ln (ft)Trunk st14170.033.0ShMt0x04.00.05530301126cBath 2 st3140.06.2ShMt0x04.00.07686321cBath 3 st2180.017.5ShMt0x04.00.0562524934cBath 4 st14150.037.8ShMt0x06.00.05987903118hBed 2 st14160.037.0ShMt0x06.00.05787903118hBed 2-A st3130.010.8ShMt0x06.00.07997953646cBed 3 st2185.022.0ShMt0x06.00.0541051043971cBed 4 st2215.037.4ShMt0x07.00.0441021053637hGame Room st2215.037.4ShMt0x07.00.0441021053637hGame Room-B st14150.020.0ShMt0x04.00.06654182cLaundry 2 st2155.023.1ShMt0x07.00.0631411335333cMedia Room-A st14160.021.1ShMt0x04.00.06265662305hRoom16 st2215.034.6ShMt0x06.00.04590933248hSewing st14180.034.0ShMt0x04.00.0521919675hWIC 2 st3140.011.4ShMt0x04.00.0741615599cWIC 3 st2190.020.5ShMt0x04.00.0532222834cWIC 4 Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm)(cfm)FR (fpm)(in)(in)Material Trunk st2 Peak AVF 585 587 0.044 549 14.0 0x0 ShtMetl st3 Peak AVF 415 413 0.052 388 14.0 0x0 ShtMetl st14 Peak AVF 299 292 0.052 548 10.0 0x0 ShtMetl st13 st13 Peak AVF 299 292 0.052 381 12.0 0x0 ShtMetl st3 2:54 pm, Aug 06, 2022 Bold/italic values have been manually overridden 2022-Jul-25 12:12:12 Right-Suite® Universal 2022 22.0.02 RSU17457 Page 4 ...de Residence (Revised) 340 2nd Ave, Atl Bch.rup Calc = MJ8 Front Door faces: N Return Branch Detail Table Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size (in)(cfm)(cfm)(ft)FR (fpm)(in)(in)Opening (in)Matl Trunk rb8 0x 1250 125 150.2 0.059 359 8.0 x0 0 ShMt rt2 rb7 0x 2590 269 136.5 0.065 1005 7.0 x0 0 ShMt rt3 rb3 0x 3030 293 135.2 0.066 555 10.0 x0 0 ShMt rt3 rb4 0x 1610 162 200.8 0.044 297 10.0 x0 0 ShMt rt2 rb5 0x 430 45 157.1 0.056 130 8.0 x0 0 ShMt rt2 rb6 0x 1090 106 178.7 0.050 313 8.0 x0 0 ShMt rt2 Return Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm)(cfm)FR (fpm)(in)(in)Material Trunk rt2 Peak AVF 439 438 0.044 559 12.0 0x0 ShtMetl rt3 Peak AVF 561 562 0.065 716 12.0 0x0 ShtMetl 2:55 pm, Aug 06, 2022