1296 BEACH AVE RES22-0188 COAB Permit Form with ConditionsFinal Plumbing
Final Electrical
Final HVAC
CC Final
Final Building*
Swimming Pool Steel
Swimming Pool Safety
Electrical Grounding & Bonding
Swimming Pool Final (Bldg)
Swimming Pool Final (PW)
Formed Columns/ Beams*
Masonry Cell Fill
Structural Steel*
OTHER:
OTHER:
OTHER:
OTHER:
OTHER:
Power Pole
Silt Fence
Piers/ Stem Walls
Underground Plumbing
Underground Electric
Foundation/ Footing
Slab**
Retaining Wall Footing
Driveway
Sewer (Building Dept)
Sewer Tap (Utilities Dept)
Rough Electric*
Rough Plumbing/ Top Out*
Rough Mechanical*
House Wrap
Wall Sheathing
Roof Sheathing
Tie-down Framing Connections
Rough Framing
Roofing In Progress
Window/Door In-Progress
Insulation Ceiling
Insulation Wall
Exterior Lath
Stucco Scratch Coat
Exterior Siding In-Progress
Brick Flashing & Ties
Early Power
Gas Rough
Gas Final*
* When all rough electric, plumbing, mechanical are complete but before any work is
covered up.
* When all gas piping is complete and wallboard is installed but before gas is
attached to any appliance. All outlets must be capped and pipe pressurized at a
minimum of 15 lbs.
* For new living space: When all construction work including electrical, plumbing,
mechanical, exterior finish, grading, required paving and landscaping is complete
and the building is ready for occupancy, but before being occupied
Additional inspections may apply to your project if your project
contains these elements:
INSPECTIONS REQUIRED FOR BUILDING PERMITS
To verify compliance with building codes, inspections of the work authorized are required at various points of the construction.
The following inspections are typically required for residential projects:
Date: Initial: Date: Initial:
_____________________________________________________
Permit Type
____________________________________________________
Permit No.
__________________________________________________________
Job Address
____________________________________________________
Contractor
POST THIS CARD WITH PERMITS AND PERMIT
DOCUMENTATION IN FRONT OF BUILDING
Construction Hours per City Code: 7am—7pm Weekdays; 9am—7pm Weekends
Building Department Public Works/Utilities Fire Department
Phone: 904-247-5826 Phone: 904-247-5834 Phone: 904-630-4789
Fax: 904-247-5845 Fax: 904-247-5843 Fax: 904-630-4203
* When forms and reinforcing steel, anchor bolts, sleeves and inserts, and all
electrical, plumbing and mechanical work is in place, but before concrete is poured.
* When all structural steel members are in place and all connections are complete,
but before such work is covered or concealed.
** FORM BOARD ELEVATION CERTIFICATE MUST BE ON-SITE FOR SLAB INSPECTION
POOL HOUSE WET BAR AND BATHROOM
RES22-0188
1296 BEACH AVE
BOSCO BUILDING CONTRACTORS
OWNER:ADDRESS:CITY:STATE:ZIP:
LIGNELLI BRIAN 1296 BEACH AVE ATLANTIC BEACH FL 32233
COMPANY:ADDRESS:CITY:STATE:ZIP:
BOSCO BUILDING
CONTRACTORS 2158 MAYPORT RD ATLANTIC BEACH FL 32233
TYPE OF
CONSTRUCTION:
REAL ESTATE
NUMBER:ZONING:BUILDING USE
GROUP:SUBDIVISION:
171833 0010 MANDALAY
JOB ADDRESS:PERMIT TYPE:DESCRIPTION: VALUE OF WORK:
1296 BEACH AVE RESIDENTIAL ALTERATION
RESIDENTIAL
ADD BATHROOM AND WET
BAR TO POOL HOUSE $38370.00
FEES
DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT
BLDG 2ND PLAN REVIEW FEE 455-0000-322-1006 0 $50.00
BUILDING PERMIT 455-0000-322-1000 0 $245.00
BUILDING PLAN CHECK 455-0000-322-1001 0 $122.50
STATE DBPR SURCHARGE 455-0000-208-0700 0 $6.26
STATE DCA SURCHARGE 455-0000-208-0600 0 $4.18
LIST OF CONDITIONS
Roll off container company must be on City approved list . Container cannot be placed on City right-of-way.
NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property
that may be found in the public records of this county, and there may be additional permits required from other
governmental entities such as water management districts, state agencies, or federal agencies.
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN
YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT
MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU
INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE
RECORDING YOUR NOTICE OF COMMENCEMENT.
MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION.
ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING
CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES .
ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY.
1 of 2Issued Date: 8/9/2022
PERMIT NUMBER
RES22-0188
ISSUED: 8/9/2022
EXPIRES: 2/5/2023
RESIDENTIAL PERMIT
CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
ATLANTIC BEACH, FL 32233
TOTAL: $427.94
2 of 2Issued Date: 8/9/2022
PERMIT NUMBER
RES22-0188
ISSUED: 8/9/2022
EXPIRES: 2/5/2023
RESIDENTIAL PERMIT
CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
ATLANTIC BEACH, FL 32233
RES22-0188By Mike Jones at 1:53 pm, Jul 10, 2022REVIEWED FOR CODE COMPLIANCE
RES22-0188
Revision Request/Correction to Comments
City of Atlantic Beach Building Department
800 Seminole Rd,Atlantic Beachr FL32233
Phone: (904) 247-5826 Email: Building-Dept@coab.us
**ALLINFORMATION
HIGHliGHTED IN
GRAY IS REQUIRED.
PERMIT#:k£.5')'A -c.j Pi
[2JRevision to Issued Permit OR DCorrections to Comments Date:7./J-7,/::LI);~:J-
Contractor/Contact Name:[3;:)<:"0 iJ'1-o~~ -1--,)D ,.)d j;5tJ(,(..
Contact Phone:Cit -'r - ~-I- / ~c 'J .)....C
Description of Proposed Revision / Corrections:
dJ5tJd!6 10 film)Qt){3-r:wJ5
_____________affirm the revision/correction to comments is inclusive ofthe proposed changes.
(printed name)
• Wi.1Iproposed revision/corrections add additional square footage to original submittal?
I1JNo EJYes(additional s.f. to be added:)
.~iII proposed revision~c.orre~ions ad~ add~ti~nal increase in building value to original submittal?
UNo D*Yes (additional Increase In building value:$)(Contractor must sign if increase in valuation]
*Signature of Contractor/Agent:_
(Office Use Only)
o Approved o Denied o Not Applicable to Department Permit Fee Due $,_
Revision/Plan Review Comments,_
Department Review Required:
Building
Planning &Zoning
Tree Administrator
Public Works
Public Utilities
Public Safety
Fire Services
Reviewed By
Date
Updated 10/17/18
By Toni Gindlesperger at 4:25 pm, Jul 27, 2022
By Mike Jones at 8:36 am, Aug 09, 2022
50.00
7/26/2022 5:03:29 PM22.0119BOSCO LIGNELLI1296 BEACH AVENUEATLANTIC BEACH, FL 32233PERMIT SET -22.07.26CLIENTMR. AND MRS. LIGNELLI 1296 BEACH AVENUE, ATLANTIC BEACH, FLORIDA 32233ARCHITECTdig ARCHITECTURE LLC13500 SUTTON PARK DR. SOUTH, SUITE 301JACKSONVILLE, FL 32224904-553-2698www.dig-architecture.comGENERAL CONTRACTOR-7/26/2022 5:03:29 PM22.0119BOSCO LIGNELLI1296 BEACH AVENUEATLANTIC BEACH, FL 32233BOSCO BUILDING CONTRACTORS2158 MAYPORT ROADJACKSONVILLE, FL 32233By Toni Gindlesperger at 4:26 pm, Jul 27, 20228:38 am, Aug 09, 2022By Mike Jones at 8:39 am, Aug 09, 2022
DRAWING NOTES:DRAWINGS ARE NOT TO BE SCALED FOR INFORMATION.ALL EXTERIOR WALLS ARE 2x6.ALL INTERIOR WALLS ARE 2x4 EXCEPT AS NOTED.ALL WALL THICKNESSES ARE ACTUAL 2x4 = 3-1/2", 2x6 = 5-1/2", 2x8 = 7-1/4", ETC.THE SIZE AND QUANTITY OF ALL EXTERIOR STEPS ARE TO BE FIELD DETERMINED BY OTHERS.ALL PLATE AND CEILING HEIGHTS ARE TAKEN FROM (TOP OF) HOUSE SLAB/BLOCK.ALL ANGLES ARE 45° UNLESS OTHERWISE NOTED.NOTED DIMENSIONS TAKE PRECEDENCE OVER SCALED DIMENSIONS.ALL DIMENSIONS ARE TO FACE OF BLOCK OR STUD WALL.ALL WOOD IN CONTACT WITH MASONRY, CONCRETE OR EARTH SHALL BE PRESSURE TREATED APPROPRIATELY FOR THE CONDITION. H = HAZARDOUS GLASS LOCATIONS.VERIFY THE KITCHEN AND VANITY LAYOUTS WITH THE DETAILS DONE BY OTHERS.CEILING HEIGHTS ARE DIMENSIONED IN RELATIONSHIP TO THE FINISHED FLOOR AND/OR DECK.1.2.3.4.5.6.7.8.9.10.11.12.13.X.XXXEXTERIOR ELEVATION IDENTIFICATIONWALL SECTION IDENTIFICATIONX.XXXTYPICAL DETAIL DESIGNATIONROOM NUMBER IDENTIFICATIONX.XXXDETAIL NUMBERSHEET WHERE DETAIL IS SHOWNDOOR NUMBER IDENTIFICATIONWINDOW NUMBER IDENTIFICATIONXCEILING HEIGHT IDENTIFICATIONWALL TYPE IDENTIFICATIONX.XXXINTERIOR ELEVATION IDENTIFICATION100MATERIALX'-X" AFFA100ROOMSYMBOL LEGENDIT IS INTENDED THAT THESE DRAWINGS ARE PREPARED FOR BUILDINGS THAT WILL CONFORM TO THE 2020 FLORIDA BUILDING CODE, RESIDENTIAL.THE MAXIMUM ALLOWABLE NUMBER OF STORIES AND HEIGHT PER LOCAL ZONING ORDINANCES AND PER THE 2014 FLORIDA BUILDING CODE, RESIDENTIAL, ARE AS FOLLOWS:A. MAX. NO. OF STORIES = (3)B. MAX. HEIGHT = 35' FROM GRADETHE BUILDING CONTRACTOR IS RESPONSIBLE FOR COMPLIANCE TO THE CODE REGUARDLESS OF ANY MISSING OR INCOMPLETE DETAILS OR NOTES.THE BUILDING CONTRACTOR AND HIS SUBCONTRACTORS SHALL CONFORM TO ANY LOCAL ORDINANCES AND SHALL VERIFY ALL DIMENSIONS, MATERIALS, AND CONDITIONS AND SHALL NOTIFY THE ARCHITECT OF ANY DISCREPANCIES PRIOR TO PROCEEDING WITH HIS WORK.VERIFY ALL FIELD CONDITIONS AND NOTIFY ARCHITECT OF ANY DISCREPANCIES BEFORE PROCEEDING WITH WORK.MAINTAIN A CURRENT AND COMPLETE SET OF CONTRACT DOCUMENTS AT THE JOB SITE.THE ELECTRICAL FLOOR PLAN IS INTENDED TO ONLY SUGGEST LOCATIONS FOR FIXTURES, OUTLETS, AND SWITCHES.ELECTRICAL, MECHANICAL, PLUMBING, AND OTHER BUILDING SYSTEMS, IF ANY, ARE TO BE DESIGNED, ENGINEERED AND ARE THE SOLE RESPONSIBILITY OF OTHERS.ALL INTERIOR AND EXTERIOR FLOOR & STEP FINISHES SHALL HAVE A NON-SLIP FINISH TO MEET ASTM C1028 STATIC COEFFICIENT OF FRICTION MIN. OF 0.6.ERECT AND MAINTAIN, AS REQUIRED BY EXISTING FIELD CONDITIONS, THROUGHOUT THE ENTIRE PORTION OF THE WORK, ALL SAFEGUARDS AND BARRICADES FOR SAFETY INCLUDING POSTING WARNING SIGNS, ENFORCING SAFETY REGULATIONS AND PROTECTION OF PROPERTY.CHECK ALL CEILING HEIGHTS AND POSSIBLE CEILING PLENUM CONDITIONS FOR CLEARANCE OF DUCT-WORK AND ALL OTHER CONSTRAINTS TO ASSURE THE LOCATION OF THE LIGHT FIXTURES AS SHOWN ON THE LIGHTING PLAN. ANY DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT IN WRITING BEFORE PROCEEDING WITH THE WORK.CONTRACTOR TO POST AND MAINTAIN SIGNAGE FORBIDDING THE USE OF NICOTINE PRODUCTS THROUGOUT ALL PHASES OF CONSTRUCTION. NICOTINE PRODUCTS ARE NOT TO BE ALLOWED WITHIN THE PERIMETER OF THE BUILDING FOOTPRINT.GENERAL CONSTRUCTION NOTES:BUILDING CODE SUMMARYGENERAL NOTES1.2. 3. 4. 5. 6.7. 8.9.10.11.TYPE VB UN-PROTECTEDOCCUPANCY CLASS -GROUP R-3DRAWING INDEXFRAMING DIMENSIONSFINISH FACE DIMENSIONSDIM.DIM.CABINET DIMENSIONSDIM.EXISTING RESIDENCETHE 2020 FLORIDA BUILDING CODE, RESIDENTIAL:2020 FBC -EXISTING BUILDING, 7TH EDITIONLEVEL 2 ALTERATIONICREGISTEREDARHITECT94268LCINTERIORDESIGNER5903STATE OF FLORIDANICHOLASJAMESRENARDBUILD :SCHEMTIC :BID :REVISIONSPERMIT :7/26/2022 5:03:29 PM22.0119BOSCO LIGNELLIINDEX22.07.25-1296 BEACH AVENUEATLANTIC BEACH, FL 32233A1001--SHEETNO.SHEET NAMEREVISION 1REVISION 2REVISION 3A1001 INDEXARCHITECTURALA2002 PROPOSED FLOOR PLANS1 22.07.26 PERMIT REVIEWS - CITY OF ATLANTICBEACH1By Toni Gindlesperger at 4:26 pm, Jul 27, 20228:39 am, Aug 09, 2022
3D40025' - 0 1/2"15' - 2 1/2"11' - 0"BATH002POOL HOUSE001EXISTING OFFICEWET BAR5' - 0"2' - 11"3' - 1"2' - 6"2' - 6"EQEQ8' - 0 1/2"11' - 0 1/2"EXISTING BATH7' - 8 1/2"EXISTING RESIDENCEEXISTING GARAGE13TH STREETBEACH AVENUE
17' - 5 1/2"12' - 10 3/4"EXISTING POOL20' - 0"20' - 0"4' SIDEWALKEXISTING DRIVEWAYEXISTING PAVER PATHEXISTING COVERED SECOND FLOOR PORCHEXISTING CONCRETE PATHCLCL
91025'09"(M)88034'51"(M)92039'32"(M)87020'28"(M)EXISTING DRIVEWAYEXISTING PAVER PATH AND PATIOEXISTING STAIR 5' - 9 1/2"6' - 7 1/4"PLATTED
LOT LINE EXISTING PAVER PATHEXISTING PAVER PATH AND PATIOAREA OF WORKLOT COVERAGE 10,618.4 SF1,643.8 SF1,119.3 SF72.6 SF387.1 SF337 SF734.1 SF1,636.5 SF 4,688 SF4,688 SF5,930.4 SFLOTEXISTING RESIDENCEEXISTING CONCRETE DRIVEEXISTING CONCRETE PATHEXISTING PAVER PATHEXISTING COVERED SECOND FLOOR PORCH AND STAIREXISTING GARAGEEXISTING PAVER PATH AND PATIOEXISTING GREEN SPACEEXISTING PERVIOUS EXSITING IMPERVIOUS100%15.5%10.5%0.7%3.6% 3.2%6.9%15.4%44.1%44.1%55.9%EXISTING RESIDENCEAAAAAAABELECTRICAL NOTES24"X48" FLUORESCENT FIXTUREPRE-WIRE AND BRACE FOR CEILING FAN W/ LIGHTWALL MTD. LIGHT AT 72" A.F.F.PENDANT LIGHT FIXTUREUNDER CABINET LITES12"X48" FLUORESCENT FIXTUREDIMMER SWITCH AT 42" A.F.F.4-WAY SWITCH AT 42" A.F.F.3-WAY SWITCH AT 42" A.F.F.SWITCH AT 42" A.F.F.SURFACE MTD. CEILING LIGHTPRE-WIRE AND BRACE FOR CEILING FANPUSH BUTTONFLOOD LIGHTSHOLLYWOOD STRIPELECTRICAL SWITCH AND LIGHT LEGEND(SEE NOTE 3)RECESS (EYEBALL) LIGHTINGRECESS LIGHTINGSMOKE AND CARBON MONOXIDE DETECTOREXHAUST FAN WITH LIGHTCEILING MTD. EXHAUST FANE.B.SDFAN/ LIGHTLOCATE ALL ELECTRICAL OUTLETS, SWITCHES, LIGHTS, SMOKE DETECTORS, FANS, AND EXHAUST FANS PER ELECTRICAL/ BUILDING CODES. VERIFY WITH BUILDER ANY SPECIAL HOOK-UPS. (RANGE HOODS, FIREPLACE FANS, LANDSCAPE LITES, SPRINKLER SYSTEM, SECURITY SYSTEM, INTERCOM SYSTEM, VACUUM SYSTEM, SWIMMING POOL, PUMPS, ETC.) INSTALL WATER/VAPOR PROOF FIXTURES IN SHOWERS AND OVER TUBS AS REQUIRED.1. 2. 3.GENERAL ELECTRICAL NOTESELECTRICAL SERVICE IS LESS THAN 600 AMPS. CALCULATION TO BE PROVIDED BY ELECTRICIAN.PROVIDE SMOKE DETECTORS PER NFPA72 A-81.2 AND CARBON MONOXIDE ALARMS PER R315 OF THE 2020 FBC-R.1. 2.CONTRACTOR ELECTRICAL NOTESSPECIFICATIONS, PRICE SUMMARY AND CHANGE ORDERS SUPERSEDE THIS ELECTRICAL PLAN.THE PURPOSE OF THIS PLAN IS TO OBTAIN AN ELECTRICAL PERMIT. FIXTURE, SWITCH AND RECEPTACLE LOCATIONS SHOWN MAY VARY DUE TO FRAMING, MECHANICAL CONFLICTS, SITE CONDITIONS OR LOCAL BUILDING CODE REQUIREMENTS.THE PURCHASER WILL DO AN ELECTRICAL WALK THROUGH WITH THE PROJECT MANAGER DURING CONSTRUCTION. THIS WALK THROUGH WILL IDENTIFY THE PREDETERMINED LOCATION OF RECEPTACLES BY THE ELECTRICIANS FOLLOWING LOCAL BUILDING CODES. AT THIS TIME, SELECTIVE LIGHT FIXTURES, PHONE AND TV JACKS WILL BE DETERMINED BY THE PURCHASER AS TO THE PREFERRED LOCATIONS.1. 2.3.FANICREGISTEREDARHITECT94268LCINTERIORDESIGNER5903STATE OF FLORIDANICHOLASJAMESRENARDBUILD :SCHEMTIC :BID:REVISIONSPERMIT :7/26/2022 5:03:30 PM22.0119BOSCO LIGNELLIPROPOSED FLOOR PLANS22.07.25-1296 BEACH AVENUEATLANTIC BEACH, FL 32233A2002--1/4" = 1'-0"A20021FLOOR PLAN - FIRST FLOORDOOR SCHEDULE - GARAGEDOOR NO. TYPEMFG. STYLE FINISHCOMMENTS0022'-4" x 8'-0"TBD MATCH MATCH1/16" = 1'-0"A20022SITE PLAN1/4" = 1'-0"A20023CEILING PLAN - FIRST FLOOR1/4" = 1'-0"A20024ELECTRICAL PLAN - FIRST FLOORLIGHTING FIXTURE SCHEDULE - INTERIORFIXTURE FIXTURE TYPE MOUNT MOUNTING HEIGHT COUNTA 4" SQUARE LED - INTERIORCEILING N/A7B INTERIOR - CEILING FANCEILINGN/A1NOTE:COLLECT WATER RUNOFF THROUGH GUTTERS INTO UNDERGROUND DRAINAGE SYSTEM AND ON SITE BUBBLER.By Toni Gindlesperger at 4:26 pm, Jul 27, 20228:39 am, Aug 09, 2022