1703 Atlantic Beach Drive SURVEY 04.13.2018 (final)MAP SHOWING ASB UILT SURVEY OF
L 0 T 18 AS SHOWN ON MAP OF ATLANTIC BEACH
COUNTRY CLUB UNIT 2
AS RECORDED IN PLAT BOOK 67 PAGES 132-137 OF THE CURRENT PUBLIC RECORDS OF DUVAL COUNTY, FLA.
CERTIFIED TO: RICHARD E. GRAVES / MONICA A. GRAVES
BANK OF AMERICA, N.A / WESTMINSTER TITLE AGENCY, INC.
CHICAGO TITLE INSURANCE COMPANY
CURVE DATA C2
S28'05'36"E
CH = 70.49'
NOTE ALL UTILITIES SHOWN R = 440.00'
HEREON WERE FROM
AS -BUILT DRAWINGS A = 70.56'
PROVIDED BY CODY'S = 09'11'19"
PROFESSIONAL SURVEYING
AND MAPPING, INC. L2 S32.41'16"E
12-18-14; JOB #10114 < 4.87'
O
9
O
o \
O \
G p0
V3
co
F° 0.
11 Gamin
vr'
0.5'
yam`
c Q °n
rn //
y
O -0
9
2 -
ocl
yJ O `
I
o
0,1A
10'x10' JEA
C1 EQUIPMENT
O \
EASEMENT
L1 N32041'1 6"W
4.87'
CURVE DATA Cl
N28'05'36"W
CH = 51.26'
R = 320.00'
A = 51.32'
A = 09'11'19"
FINAL; 'VJ.O. #171722; 4-4-19 (FIELD)
FOUNDATION, F.F.E.; W.O.# 166619; 9-4-18 (FIELD)
LOT & HOUSE S-O(GOOD SET F.F.E.) W.O.#165605: 7-27-18 (FIELD)
SHIFT I10USE FORWARD 15 FEET; 07-26-18 (OFFICE)
THIS SURVEY WAS PERFORMED WITHOUT THE BENEFIT OF A TITLE COMMITMENT.
THERE MAY BE ADDITIONAL EASEMENTS AND/OR RESTRICTIONS THAT ARE NOT SHOWN
ON THIS SURVEY THAT MAY BE FOUND IN THE PUBLIC RECORDS OF THIS COUNTY.
DENOTES DIRECTION OF FLOW
00.0) - DENOTES PRE -CONSTRUCTION ELEVATION
00.0 - DENOTES POST -CONSTRUCTION ELEVATIONS
NOTE:
SIDE/FRONT BUILDING TIES ARE TO THE FOUNDATION
RFNCHMA
NAIL &
DRIC:
ISK FND LB 3848
ON MOST N'LY PEGGED NAIL
AT C.L.I. OF ATLANTIC BEACH
DR. & ATLANTIC BEACH CT.
ELEVATION: (9.05)
ELEVATIONS SHOWN HEREON
REFER TO NAVD OF 1988
DENOTES FOUND 1/2"
IRON PIPE LB 3848
UNLESS OTHERWISE NOTED
DENOTES FOUND 1/2"
Q IRON PIPE NO LD.
UNLESS OTHERWISE NOTED
RC — DENOTES RECLAIMED WATER METER
WM — DENOTES WATER METER
TRB — DENOTES TELEPHONE RISER BOX
ATTRB — DENOTES AT&TELEPHONE RISER
ATTHH — DENOTES AT&T TELECOM HAND HOLE
THE LOT SHOWN HEREON IS IN THE SPECIAL FLOOD HAZARD ZONE -X" AS SHOWN
ON FLOOD INSURANCE RATE MAP 0406 J FOR THE CITY OF JACKSONVILLE, FLORIDA, DATED 11-02-18
ALL AMERICAN SURVEYORS-
9OF
8FLORID8 - LICENSED LAND
UA,
INC.
IAND SURVEYORS - 3751 SAN JOSE PLACE, SUITE 7
SINESS No. J857_
I- 4I
ALL
AMERICAN
SURVEYORS
OF FLORIDA,
INC.
8I
Le end
F.F.E. -FINISH FLOOR ELEVATION - THIS IS TO CERTIFY THAT THE ABOVE LANDS WERE SURVEYED UNDER MY RESPONSIBLE
COV. - CDVERED A/C - AIR CONDITIONER SUPERVISION AND DIRECTION, THAT THERE ARE NO ENCROACHMENTS EXCEPT AS SHOWN
FND. - Fl)UND I.D. = IDENTIFICATION
ESM' - EASEMENT JEA - JACKSONVILLE ELECTRIC AND THAT THE SURVEY SHOWN HEREON MEETS THE MINIMUM TECHNICAL STANDARDSSURVEYORSANDMAPPERS
CONC - CONCRETE AUTHORITY SET FORTH BY THE FLORIDA BOARD OF PROFESSIONAL
MON. - MONUMENT P.T. = POINT OF TANGENCY
LP. - IRON PIPE P.C.P. = PERMANENT CONTROL POINT PURSUANT TO CHAPTER 472.027 / CHAPTER 61G17-6, FLORIDA STATUTES.
LR. - IIK)N ROD P.C.— POINT OF CURVE
p = CELTA ANGLE P.R.C. — POINT OF REVERSE CURVE SURVEY NOT VALID- UNLESS EMBOSSED BY SEALCH - CHORD P.C.C. - POINT OF COMPOUND CURVE
A - ARC LENGTH B.R.L - BUILDING RESTRICTION JAMES D. HARRISSONI JR., No. 2647
R - F'ADIUS F.P.&L= FLORIDA POWER h LIGHT
CALC.) - CALCULATED
yP) -TYPICAL
D) - KED NATIONAL GEODETIC VERTICAL
MICHAEL A. GA.RRETT, No. 6643_
e
20' 7 C! NGVD -
P3 —Pur
DATUM
R -RADIAL LINE SCALE 1 l•'
LINENAVD —
AMERICAN VERTICAL0 lee_ +^
DNORTH
ATUM
R/W RI OF—WAY P.I. - POINT OF INTERSECTION
x— - FENCE EOW - EDGE OF WATER DATE 04-13-18 LORI A -REGISTERED S OR ANTS MAPPER
W) - }WITNESS TOB_ — TOP OF BANK I_.
F. B. PRINT D. C.— N/A DR. BY TTH DIR. P:\2018 (83200) ORDER No. 171722-FNL FILE 83829