Loading...
1703 Atlantic Beach Drive SURVEY 04.13.2018 (final)MAP SHOWING ASB UILT SURVEY OF L 0 T 18 AS SHOWN ON MAP OF ATLANTIC BEACH COUNTRY CLUB UNIT 2 AS RECORDED IN PLAT BOOK 67 PAGES 132-137 OF THE CURRENT PUBLIC RECORDS OF DUVAL COUNTY, FLA. CERTIFIED TO: RICHARD E. GRAVES / MONICA A. GRAVES BANK OF AMERICA, N.A / WESTMINSTER TITLE AGENCY, INC. CHICAGO TITLE INSURANCE COMPANY CURVE DATA C2 S28'05'36"E CH = 70.49' NOTE ALL UTILITIES SHOWN R = 440.00' HEREON WERE FROM AS -BUILT DRAWINGS A = 70.56' PROVIDED BY CODY'S = 09'11'19" PROFESSIONAL SURVEYING AND MAPPING, INC. L2 S32.41'16"E 12-18-14; JOB #10114 < 4.87' O 9 O o \ O \ G p0 V3 co F° 0. 11 Gamin vr' 0.5' yam` c Q °n rn // y O -0 9 2 - ocl yJ O ` I o 0,1A 10'x10' JEA C1 EQUIPMENT O \ EASEMENT L1 N32041'1 6"W 4.87' CURVE DATA Cl N28'05'36"W CH = 51.26' R = 320.00' A = 51.32' A = 09'11'19" FINAL; 'VJ.O. #171722; 4-4-19 (FIELD) FOUNDATION, F.F.E.; W.O.# 166619; 9-4-18 (FIELD) LOT & HOUSE S-O(GOOD SET F.F.E.) W.O.#165605: 7-27-18 (FIELD) SHIFT I10USE FORWARD 15 FEET; 07-26-18 (OFFICE) THIS SURVEY WAS PERFORMED WITHOUT THE BENEFIT OF A TITLE COMMITMENT. THERE MAY BE ADDITIONAL EASEMENTS AND/OR RESTRICTIONS THAT ARE NOT SHOWN ON THIS SURVEY THAT MAY BE FOUND IN THE PUBLIC RECORDS OF THIS COUNTY. DENOTES DIRECTION OF FLOW 00.0) - DENOTES PRE -CONSTRUCTION ELEVATION 00.0 - DENOTES POST -CONSTRUCTION ELEVATIONS NOTE: SIDE/FRONT BUILDING TIES ARE TO THE FOUNDATION RFNCHMA NAIL & DRIC: ISK FND LB 3848 ON MOST N'LY PEGGED NAIL AT C.L.I. OF ATLANTIC BEACH DR. & ATLANTIC BEACH CT. ELEVATION: (9.05) ELEVATIONS SHOWN HEREON REFER TO NAVD OF 1988 DENOTES FOUND 1/2" IRON PIPE LB 3848 UNLESS OTHERWISE NOTED DENOTES FOUND 1/2" Q IRON PIPE NO LD. UNLESS OTHERWISE NOTED RC — DENOTES RECLAIMED WATER METER WM — DENOTES WATER METER TRB — DENOTES TELEPHONE RISER BOX ATTRB — DENOTES AT&TELEPHONE RISER ATTHH — DENOTES AT&T TELECOM HAND HOLE THE LOT SHOWN HEREON IS IN THE SPECIAL FLOOD HAZARD ZONE -X" AS SHOWN ON FLOOD INSURANCE RATE MAP 0406 J FOR THE CITY OF JACKSONVILLE, FLORIDA, DATED 11-02-18 ALL AMERICAN SURVEYORS- 9OF 8FLORID8 - LICENSED LAND UA, INC. IAND SURVEYORS - 3751 SAN JOSE PLACE, SUITE 7 SINESS No. J857_ I- 4I ALL AMERICAN SURVEYORS OF FLORIDA, INC. 8I Le end F.F.E. -FINISH FLOOR ELEVATION - THIS IS TO CERTIFY THAT THE ABOVE LANDS WERE SURVEYED UNDER MY RESPONSIBLE COV. - CDVERED A/C - AIR CONDITIONER SUPERVISION AND DIRECTION, THAT THERE ARE NO ENCROACHMENTS EXCEPT AS SHOWN FND. - Fl)UND I.D. = IDENTIFICATION ESM' - EASEMENT JEA - JACKSONVILLE ELECTRIC AND THAT THE SURVEY SHOWN HEREON MEETS THE MINIMUM TECHNICAL STANDARDSSURVEYORSANDMAPPERS CONC - CONCRETE AUTHORITY SET FORTH BY THE FLORIDA BOARD OF PROFESSIONAL MON. - MONUMENT P.T. = POINT OF TANGENCY LP. - IRON PIPE P.C.P. = PERMANENT CONTROL POINT PURSUANT TO CHAPTER 472.027 / CHAPTER 61G17-6, FLORIDA STATUTES. LR. - IIK)N ROD P.C.— POINT OF CURVE p = CELTA ANGLE P.R.C. — POINT OF REVERSE CURVE SURVEY NOT VALID- UNLESS EMBOSSED BY SEALCH - CHORD P.C.C. - POINT OF COMPOUND CURVE A - ARC LENGTH B.R.L - BUILDING RESTRICTION JAMES D. HARRISSONI JR., No. 2647 R - F'ADIUS F.P.&L= FLORIDA POWER h LIGHT CALC.) - CALCULATED yP) -TYPICAL D) - KED NATIONAL GEODETIC VERTICAL MICHAEL A. GA.RRETT, No. 6643_ e 20' 7 C! NGVD - P3 —Pur DATUM R -RADIAL LINE SCALE 1 l•' LINENAVD — AMERICAN VERTICAL0 lee_ +^ DNORTH ATUM R/W RI OF—WAY P.I. - POINT OF INTERSECTION x— - FENCE EOW - EDGE OF WATER DATE 04-13-18 LORI A -REGISTERED S OR ANTS MAPPER W) - }WITNESS TOB_ — TOP OF BANK I_. F. B. PRINT D. C.— N/A DR. BY TTH DIR. P:\2018 (83200) ORDER No. 171722-FNL FILE 83829