Loading...
1762 Atlantic Beach Drive SURVEY 04.10.2017MAP SHOWING ASBUILT BOUNDARY SURVEY OF LOT 71 AS SHOWN ON MAP OF ATLANTIC BEACH COUNTRY CLUB UNIT 2 AS RECORDED IN PLAT BOOK 67 PAGES 132-137 OF THE CURRENT PUBLIC RECORDS OF DUV/AL COUNTY, FLA. CERTIFIED TO: NATHAN JOEL HARRIS & CHELSEA RUSSELL W/NICK/ / WESTMINSTER TITLE AGENCY, INC. / JP MORGAN CHASE BANK, N.A. / CHICAGO TITLE INSURANCE COMPANY CURVE DATA Cl S37'16'20"E CH = 60.19' R = 400.00' A = 60.25' 08'37'48" 11.2) PROPOSED DESIGN GRADES 10.5] EXISTING LOT GRADES 569 BENCHMARK: NORTH RIM OF MANHOLE IN FRONT OF LOT 72 ON ATLANTIC BEACH DRIVE ELEVATION: (9.51) ELEVATIONS SHOWN HEREON REFER TO NAVD OF 1988 ADD ASBUILT GRADES; W. .# 165777; 08-02-18 (FIELD) 0 -FOUND 1/2" IRON PIPE FINAL; W.O.# 164987; 06-29-18 (FIELD) LB #3848 FOUNDATION, F.F.E.; W.O. 159613; 11-14-17 (FIELD) NOTE: QT -DENOTES TELECOM HAND HOLE LOT & HOUSE STAKE OU (GOOD -SET F.F.E.); W.O.# 158372; 10-11-17 (FIELD) SIDE/FRONT TIES ARE TO THE FOUNDATION. -DENOTES WATER METER THIS SURVEY WAS PERFORMED WITHOUT THE BENEFIT OF A TITLE COMMITMENT. WM THERE MAY BE ADDITIONAL EASEMENTS AND/OR RESTRICTIONS THAT ARE NOT SHOWN ON THIS SURVEY THAT M Y BE FOUND IN THE PUBLIC RECORDS OF THIS COUNTY. UNDERGROUND ENCROACHMENTS NOT LOCATED THE LOT SHOWN HEREON IS IN THE SPECIAL FLOOD HAZARD ZONE "X" AS SHOWN ON FLOOD INSURANCE RATE MAP 0406 H FOR THE CITY OF JACKSONVILLE, FLORIDA, DATED 06-03-13 AL AMERICAN SURVEYORS OF FLORIDA, INC. LAD SURVEYORS - 3751 SAN JOSE PLACE, SUITE 15 - JACKSONVILLE, FLORIDA, 32257 - 904/279-0088 - UCENSED LAND BUSINESS NO. 3857 FND. FOUNDle d CONC = CONCRETE 5 I.D. IDENTIFICATION A/C = AIR CONDITIONER THIS IS TO CERTIFY THAT THE ABOVE LANDS WERE SURVEYED UNDER MY RESPONSIBLE I.P. 1 P. TYPICAL IRON PIPE BOC = BACK CURB SUPERVISION AND DIRECTION, THAT THERE ARE NO ENCROACHMENTS EXCEPT AS SHOWN 4 I.R. IRON ROD N.G. = NATURALAL GROUND TW = TOP OF WALL AND THAT THE SURVEY SHOWN HEREON MEETS THE MINIMUM TECHNICAL STANDARDS SET In, DELTA ANGLE BW - BOTTOM of WALL FORTH BY THE FLORIDA BOARD OF PROFESSIONAL SURVEYORS AND MAPPERS PURSUANT CH A CHORD ARC LENGTH P.T. = POINT OF TANGENCY P.C.P. = PERMANENT CONTROL POINT TO CHAPTER 472.027 / CHAPTER 61G17-6, FLORIDA,STA UTES._ ALL R RADIUS P.C. - POINT OF CURVE MERICAN C) CALCULATED P.R.C. POINT OF REVERSE CURVE URVEYORSD) A DEED PLAT P.C.C. = POINT OF COMPOUND CURVE SURVEY NOT VALI9:UNiESS EMBOSSED BY SEAL F FLORIDA R RADIAL LINE B.R.L. BUILDING RESTRICTION LINE F.P.&L.= FLORIDA POWER & LIGHT JAMES D: MARRISON, JR., No. 2647 INC. ' R/W A) CENTER LINE RIGHT-OF-WAY ACTUAL x- FENCE LB - UCENSED BUSINESS NGVD = NATIONAL GEODETIC VERTICAL MICHABL: WRETT, No. 6643 SCALE 1'=20 f0 % W) F.F.E. WITNESS FINISH FLOOR ELEVATION DATUM NAVD - NORTH AMERICAN VERTICAL DATUM 9 P.I. = POINT OF INTERSECTIONWIDTH D DEPTH EOW - EDGE OF WATER DATE 04-10-17 STEREO S EYOR A MAPPERMESMITEREDENDSECTIONTOB = TOP OF BANK FLORI _. 81 F. B. PRINT D. C. N/A DR. BY BRB DIR. P:\2017 (81300) ORDER N0. 165777 -GRADES FILE 81804