Loading...
Permit 734 - 748 Cavalla RoadNOTES FOR REACTIONS Building reactions are based on the following building data: ----- Anc. Bolt Width (ft = 50.0 Length t) = 75.0 Eove Height (ft)16.0 16.0 Roof Slope rise/12) 1.0 1.0 Dead Load psf ) _ .0 Collateral Load (psf ) - 3.0 Roof Live Load (psf Frame Live Load 20.0 12.0 l sf Wind Seed (mph O Wind Code BC 00 Exposure C Closed/Open C Importance - Wind = 1.00 Importance - Seismic - 1.00 Seismic Coeff (Fa•Ss) = 0.24 Id Description 1 DL+CO+LL 2 0.60DL+WL1 3 0.60DL+WR1 4 0.60DL+WP 5 O.60DL+WR I +WS GENERAL NOTES (1.) APPLICATION OF ENGINEERS SEAL IS FOR METAL BUILDING ONLY AND DOES NOT E RESENT THE PROFESSIONAL OF RECORD. (2.)FOUNDA INDESIGN AND CONSTRUCTION ARE NOT THE RESPONSIBILITY OF THE METAL BUILDG (3.) ANCHOR BOLTS SHALL BE ACCURATELY SET TO A TOLERANCE OF +/- 1/8" IN BOTH ELEVATION AND LOCATION. (4.) THE BUILDING REACTION DATA REPORTS THE LOADS WHICH THIS BUILDING PLACES N THE FOUNDATION. THE FOUNDATION IS TO BE DESIGNED BY A QUALIFIED ENGINEER TO SUPPORT THE BUILDING REACTIONS IN ADDITION TO OTHER LOADS IMPOSED BY THE BUILDING USE OR OCCUPANCY WITH RESPECT TO JOB SITE CONDITIONS. (5.) ALL ANCHOR BOLTS TO BE ASTM SPECIFICATION A307 UNLESS OTHERWISE. NOTED (6J VALUES GIVEN FOR BENDS AND ANCHOR BOLT TOTAL LENGTHS ARE SUGESTEO LENG'HS ONLY. IT IS THE RESPONSIBILITY OF THE FOUNDATION ENGINEER TO DETERMINE THESE VALUES SINCE THEY ARE A FUNCTION OF CONCRETE STRENGTH AS WELL AS OTHER FACTDRS. FILE COPV lql i Q T t_ COLUMN LINE IV IV FRAME UNE RIGID FRAME: ANCHOR BOLTS & BASE PLATES --- Frm ----- Col ----- Anc. Bolt --------------------- Base Plate (in Grout Line Line NoO(in) Wid Len hk (in) 2 0 A 4 0.750 8.000 10.31 0.500 0.0 2 0 F 4 0.750 8.000 10.31 0.500 0.0 2 • Frame lines: 2 3 RIGID FRAME: BASIC COLUMN REACTIONS (k ) ID 12758 FOR APPROVAL Frame Column ---- Dead ---- -Collateral- ----Live---- --Wind-L1--- --Wlnd_RI--- --Wind-L2--- Line Line Horiz Vert Horiz Vert Horiz Vert Horiz Vert Horiz Vert Horiz Vert 2 • A 0.89 1.81 1.07 1.88 4.25 7.50 -9.59 -14.40 -2.60 -9.50 -8.10 -8.36 2 0 F -0.89 1.81 -1.07 1.88 -4.25 7.50 2.60 -9.50 9.59 -14.40 1.11 -3.41 Frame Column--Wind_R2--- -Seismic-L---Seismic-R-- --LnWind-L----LnVnd-R-- Line Line Horiz Vert Horiz Vert Horiz Vert Horiz Vert Horiz Vert 2 • A -1.11 -3.41 -0.16 -0.10 0.16 0.10 -3.14 -13.23 -3.59 -10.69 2 • F 8.10 -8.36 -0.16 0.10 0.16 -0.10 3.59 -10.69 3.14 -13.23 2 • Frame lines: 2 3 ENDWALL COLUMN: REACTIONS, ANCHOR BOLTS, & BASE PLATES --------------------Column-Reactions CENTURY STEEL BLDG: (k )------------------- ID 12758 FOR APPROVAL PROJECT JACKSONVILLE, FL ADDRESS OTHER, EXPLAIN -------------- Out-Of-Plane ------- ---------------- Frm Col Dead Coll Live Wind -Left Wind -Right Wd P Wd S Anc. Bolt Base Plate (in) Grout Line Line Vert Vert Vert Horiz Vert Horiz Vert Horiz Horiz NoD(in) Wid Len Thk (in) 1 F 0.2 0.2 1.1 0.0 -1.1 0.0 -2.0 0.0 0.0 2 0.625 7.000 8.000 0.188 0.0 1 E 0.7 0.7 3.9 0.0 -4.3 0.0 -6.4 -3.2 3.5 2 0.625 7.000 8.000 0.188 0.0 1 C 0.7 0.7 3.9 0.0 -6.4 0.0 -4.3 -3.2 3.5 2 0.625 7.000 8.000 0.188 0.0 1 A 0.2 0.2 1.1 0.0 -2.0 0.0 -1.1 0.0 0.0 2 0.625 7.000 8.000 0.188 0.0 4 F 0.2 0.2 1.5 0.0 -2.0 0.0 -1.2 0.0 0.0 2 0.625 7.000 8.000 0.188 0.0 4 E 0.6 0.7 4.7 0.0 -6.2 0.0 -4.0 -3.0 3.3 2 0.625 7.000 8.000 0.188 0.0 4 D 0.6 0.6 4.1 0.0 -3.6 0.0 -5.2 -2.8 3.1 2 0.625 3.500 8.000 0.188 0.0 4 B 0.3 0.3 2.0 0.0 -1.6 0.0 -3.0 -1.4 1.6 2 0.625 3.500 8.000 0.188 0.0 4 A 0.1 0.1 ' 0.4 0.0 -0.4 0.0 -0.4 0.0 0.0 2 0.625 7.000 8.000 0.188 0.0 BRACING REACTIONS, PANEL SHEAR t Reactions (k ) Panel ---Wall-- Col --Wind----Seismic- Shear Lac Line Line Harz Vert Harz Vert (Ib/ft) ------ L-EW 1 45 F -SW F 86 R -EW 4 59 13 -SW A 58 FILE COPY URAWING slAlUSI FOR CONSTRUCTION FOR PERMIT ONLY CENTURY STEEL BLDG: PROJECT 50.0 x 75.0 x 16.0 ID 12758 FOR APPROVAL PROJECT JACKSONVILLE, FL ADDRESS OTHER, EXPLAIN -------------- 41 v��-ti 4�'� - ,•Cid � 3 :C) fi r/7 Air ANCHOR BOLT PLAN DESIGN: I DRAFT: T CHECK: