Loading...
176 OCEAN BLVD RESO22-0056 LEAN TO SHED Building Permit Application Updated 10/9/18 ;----j - ''''''),4rCity of Atlantic Beach Building Department **ALL INFORMATION 800 Seminole Road, Atlantic Beach, FL 32233 HIGHLIGHTED IN GRAY U,»j IS REQUIRED. Phone: (904) 247-5826 Email: Building-Dept@coab.us Job Address: 176 Ocean Blvd.,Atlantic Beach, Florida 32233 Permit Number: RESOZZ— 00 S6,,, Legal Description Lot 5 Block 30 Subdivision "A"; Plat Book 5 Pages 69 RE# 1102.0 4.. -0060 Valuation of Work(Replacement Cost)$ 2 , 3 00 - Heated/Cooled SF Non-Heated/Cooled • Class of Work: ❑New ' Addition ❑Alteration ❑Repair ❑Move XIDemo ❑Pool DWindow/Door • Use of existing/proposed structure(s): DCommercial XResidential • If an existing structure,is a fire sprinkler system installed?: ❑Yes ANo • Will tree(s)be removed in association with proposed project? ❑Yes(must submit separate Tree Removal Permit) No Describe in detail the type of work to be performed: (1) Build a Lean-To Shed(10'4"x 6'2")addition to pre-existing detached garage(13'6"x 10'11"). NOTE:See Attached Memorandum and Enclosures (2) Use both pre-existing impervious slab(23sf)and poured slab&footer(41sf)for shed footprint(64sf). (3) DEMO nearby pre-existing impervious slab(84sf)as"good-faith"effort to make Building Permit a "win"for COAB,by net reclaiming pervious soil(43.98sf net)and improved water runoff. Florida Product Approval# for multiple products use product approval form Property Owner Information Name Christopher Thomassy Address 176 Ocean Blvd. City Atlantic Beach State FL Zip 32233 Phone 904.716.6690 E-Mail Chris.Thomassy@Gmail.com Owner or Agent(If Agent, Power of Attorney or Agency Letter Required) Contractor Information Name of Company Qualifying Agent Address City / State Zip Office Phone Job Site Contact Number State Certification/Registration# E-Mail Architect Name&Phone# Engineer's Name&Phone# Workers Compensation Insurer OR Exempt ü Expiration Date Application is hereby made to obtain a permit to do the w• and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that . work will be performed to meet the standards of all the laws regulating construction in this jurisdiction. I understand that a s-•arate permit must be secured for ELECTRICAL WORK, PLUMBING,SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS,TA S,and AIR CONDITIONERS,etc. NOTICE: In addition to the requirements of this permit,there may be additional restrictions appl. able to this property that may be found in the public records of this county,and there may be additional permits required from ether governmental entities such as water management districts,state agencies,or federal agencies. OWNER'S AFFIDAVIT:I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT.MAY RESULT IN YOUR PAYI G TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN F • A , ' NSULT WITH YOUR LENDER OR AN ATTORNEY : - ORE RECORDIN c 6.• ' '�,:.11 ' COMMENCEMENT. wag w. (Signature of Ow or gent) (Signat e of Contractor) Signed and sworn to(or affir ed)before me th i d:y of Signed and sworn to(o .ffirmed)before me this day of SEKEM3Cii— 2Cz. r4 k•1 ►i'gi„► , by • TONI GINDLESPERGER 1 r .......111MY COMMISSION#GG -,..L.1 is , u .Ir . • (Signature of Notary) EXPIRES:October 6,2023 ',ended Thru Notary Public Underwriters [ ]Pe.—nrSF$ally mown OR [ ]Personally Known OR [ ]Produced Identification [ ]Produced Identification Type of Identification: 1Th ,( _ Type of Identification: ,-sl-A.T.-r-;,,, Owner Builder Affidavit **ALL INFORMATION "' `� City of Atlantic Beach Building Department GRAY IS REQUIRED. '" sl v 800 Seminole Rd, Atlantic Beach, FL 32233 HIGHLIGHTED IN • --rig', Phone: (904) 247-5826 Email: Building-Dept@coab.us PERMIT#: I. FLORIDA STATUTES; CHAPTER 489, FLORIDA STATUTES, PART 1 "CONSTRUCTION CONTRACTING" REQUIRES OWNER/BUILDER TO ACKNOWLEDGE THE LAW: DISCLOSURE STATEMENT FOR SECTION 489.103(7), FLORIDA STATUTES: STATE LAW REQUIRES CONSTRUCTION TO BE DONE BY LICENSED CONTRACTORS. YOU HAVE APPLIED FOR A PERMIT UNDER AN EXEMPTION TO THAT LAW. THE EXEMPTION ALLOWS YOU,AS THE OWNER OF YOUR PROPERTY,TO ACT AS YOUR OWN CONTRACTOR EVEN THOUGH YOU DO NOT HAVE A LICENSE. YOU MUST SUPERVISE THE CONSTRUCTION YOURSELF. YOU MAY BUILD OR IMPROVE A ONE OR TWO FAMILY RESIDENCE OR A FARM OUTBUILDING. YOU MAY ALSO BUILD OR IMPROVE A COMMERCIAL BUILDING AT A COST OF$25,000.00 OR LESS. THE BUILDING MUST BE FOR YOUR USE AND OCCUPANCY. IT MAY NOT BE BUILT FOR SALE OR LEASE. IF YOU SELL OR LEASE A BUILDING YOU HAVE BUILT YOURSELF WITHIN ONE YEAR AFTER THE CONSTRUCTION IS COMPLETE,THE LAW WILL PRESUME THAT YOU BUILT IT FOR SALE OR LEASE, WHICH IS IN VIOLATION OF THIS EXEMPTION. YOU MAY NOT HIRE AN UNLICENSED PERSON AS YOUR CONTRACTOR. YOUR CONSTRUCTION MUST BE DONE ACCORDING TO THE BUILDING CODES AND ZONING REGULATIONS. IT IS YOUR RESPONSIBILITY TO MAKE SURE THAT PEOPLE EMPLOYED BY YOU HAVE LICENSES REQUIRED BY STATE LAW AND BY COUNTY OR MUNICIPAL LICENSING ORDINANCES. II. INJURY LIABILITY;SINCE OWNERS MAY BE LIABLE FOR INJURIES TO WORKERS THEY HIRE,THE BUILDING DEPARTMENT SUGGESTS WORKER'S COMPENSATION INSURANCE BE PURCHASED. . III. IRS WITHHOLDING; OWNERS HIRING WORKERS BECOME EMPLOYERS AND SHOULD ALSO OBSERVE IRS WITHHOLDING TAX AND/OR FORM 1099 REQUIREMENTS ON THE WORKERS THEY EMPLOY ON THEIR IMPROVEMENT TRADES. IV. PENALTY; UNLICENSED CONTRACTORS CANNOT BE EMPLOYED UNDER ANY CIRCUMSTANCES. OWNERS BEING SUBJECT TO $5,000 PENALTY UNDER FLORIDA STATUTE NO.455-228(1). AN "OCCUPATIONAL LICENSE" IS NOT ADEQUATE. THE OWNER SHOULD PHYSICALLY SEE THE COUNTY"CERTIFICATE OF COMPETENCY" OR THE FLORIDA"CONTRACTORS CERTIFICATE" TO ASCERTAIN IF A PERSON IS A LICENSED CONTRACTOR. CONTACT THE BUILDING DEPARTMENT(904- 247-5826 OR BUILDING-DEPT@COAB.US ) IF IN DOUBT. V. ACKNOWLEDGEMENT; I HEREBY ACKNOWLEDGE THAT I HAVE READ THE ABOVE DISCLOSURE STATEMENT AND THAT I COMPLY WITH ALL THE REQUIREMENTS FOR THE ISSUANCE OF AN OWNER-BUILDER PERMIT. Job Address: 176 OCEAN BLVD.,ATLANTIC BEACH, FLORIDA 32233 Owner Name: Christopher K. Thomassy, CDR USN (Ret.), HI-1074 Phone Number: 904.716.6690 TEXT/TALK Mailing Address: 176 Ocean Blvd. City: Atlantic Beach State: FL Zip: 32233-5224 Notarized Signature of Owner - The forego`nginsstrument was acknowledged before me this I day of_S iE�s3c►� , 2 22,, in the State of Florida, County of ll�� C\ Signature of Notary Public do LA-- J [ ) Personally Known OR [ ) Produced Identification z°`!:i,:t�, TONI GINDLESPERGER Type of Identification: L---, ! _F . ':,,. MY COMMISSION#GG 353178 •. .;T= EXPIRES:October 6,2023 '9jF9F F;°�' Bonded Thru Notary Public Underwriters 18 MEMORANDUM FOR THE RECORD 31 August 2022 To: Building Department,City of Atlantic Beach(COAB), Florida From: Christopher Thomassy, Property Owner, 176 Ocean Blvd.,Atlantic Beach, Florida Building Permit Application and Compliance Plan of Action—176 Ocean Blvd.,Atlantic Beach,Florida Type of Work to be Performed (1) Build a Lean-To Shed(10'4"x 6'2")addition to pre-existing detached garage(13'6"x 10' 11"). (2) Use both pre-existing impervious slab(23sf)and poured slab&footer(41sf)for shed foundation (64sf). (3) DEMO nearby pre-existing impervious slab(84sf)as"good-faith"effort to make Building Permit a "win"for the City of Atlantic Beach,by net reclaiming pervious soil(43.98sf net)and improve water runoff retention. Background Stop-Work Order: On 08.26.2022,COAB Building Inspector arrived unexpectedly on subject property with an anonymous note urging him to"take a look at 176 Ocean Boulevard...building going on...no permit." I readily confessed-I alone-was nearing completion of a lean-to shed,attached to a pre-existing detached garage,and had not pulled a permit. I had,and have, no appropriate excuse for my offense. A stop-work order was issued. I was directed to provide information on work performed and submit a Building Permit Application. All work on lean-to shed ceased 8.26.2022. Note:The dwelling at 176 Ocean Blvd.was built in 1936,and all known pre-existing impervious materials were estimated to have been added by previous property owners between 1979-1989. Enclosures of Memorandum (Encl. 1) Building Permit Application. (Encl. 2) Owner Builder Affidavit. (Encl. 3) Impervious Surface& Property Set-Backs—Subject Property Case Study. (Encl.4) Scope-of-Work Completed as of 08.26.2022. Compliance Plan of Action Option 1: Under a COAB approved building permit,comply with codes,directives and inspections to complete the construction of the lean-to shed; Demolish(DEMO)pre-existing adjacent"old dog pen"slab for a net return and improvement of pervious soil on subject property(43.98sf). Option 2: Building permit disapproved. Seek building permit to DEMO lean-to shed and return footprint and garage to previous condition. Applicant Recommendation • Approve Option 1 with any required additional guidance. • Pay applicable fines and fees. • Volunteer 50hrs of Community Service to the COAB Building Department for administrative or field duties. Impervious Surface & Property Set-Backs — Subject Property w Case Study (Encl. 3) MAP SHG.ZING BOUNDARY S&.3VEY OF LOT s BLOCK 30 AS SHOWN ON MAP OF 57/8,0/VAS-4,-4./"•4" 4 7 2 4NT/G ,g4464/ AS RECORDED IN PLAT BOOK S PACES 69 OF THE PUBLIC RECORDS OF DUVAL COUNTY, FLORIDA CER77FIED FOR: C b-if-, -roLa.l •'Me N�..._35y • I`I"►.v,r F .r -.. . .rti-r t_,Loir•-+ .. .."--n=.e1.E-15 T-i F t.—rS. F-'�•—iO t....ic . 5.-'5e�4-4..,,..►._l,11..61.E2---tf. � tt-So..J 5 1 s N o ti 0 o q ��Co `"//0. 30, H a X, si4 08 r C • k • I ov. ,.•3- w2"7.L ' - II.6• .�I . a ' • . , 0 V _ ` ,r rwo sTogy . ( I 1. O • • • - . , " w/POO,SW/.✓SLE ` f (v� Q o L V 1 gar-85a *-----N4 Z 7.5-' . X Q °v. ct, I•. �' —I: 6' ood7 _ V 2.8 !•.- 7•8 O . ... 2, /09.70 ' 1.0. 4 Topic Area --vC.6 e_T,c,Lfl 'r.Q•Ci 4,e24•- >>S--,C+.s. NOT VALID UNLESS EMBOS.stU W1T7-1 SEAL OF THE UNDERSIGNED. THE PROPERTY SHOWN HEREON APPEARS TO LIE WITHIN FLOOD HAZARD ZONE AS$�q�,Ep FROM FLOOD INSURANCE RATE MAPOOO/FOR ATL4../r7 5,6-.4 ca FLORIDA, DATED 7-BY TRI—STATE LAND SURVEYORS, INC. 8411 BA YMEADOWS WAY SUITE #Z JACKSONVILLE, FLORIDA 32256 (904) 731-7235 LEGEND I HEREBY CERTIFY THAT THE ABOVE LANDS WERE SURVEYED UNDER MY •=roc.NON RESPONSIBILE SUPERVISION AND DIRECTION, THAT THERE ARE NO •Rp1 OM ENCROACHMENTS EXCEPT AS SHOWN AND THAT THE SURVEY SHOWN (SET WIN Q11/LS 4144) HEREON MEETS THE MINIMUM TECHNICAL STANDARDS SET FORTH BY -FENCE THE FLORIDA BOARD OF LAND SURVEYORS PURSUANT TO SECTION ""‘Pli o ROM 441(FOUND) 472.027, FLORIDA STATUTES. ®cross aur LRL WHO RLTAVCRQV LINE RA, EASEMENT LARRY00. EDD S r j 144 RA, awr-er-sur // am COMM SCALE: �"- ZO f COMMUNE i�r— s�.s.4.411I A/G Al! l!srA IVIG PAD "CIS N'�/�•%EY TATE OF FLORIDA (RI RADIAL L forma- DATE: 3 3/-93 , FR 7/nR vn 11- ORDER NO. 9?•-70 f34 Impervious Surface & Property Set-Backs — Subject Property Case Study (Encl. 3) � . . '` #.40CITY OF ATLANTIC BEACH \ DEPARTMENT OF PUBLIC WORKS j 1200 Sandpiper Lane `,17 =" Atlantic Beach,FL 32233 TELEPHONE:(904)247-5834 J,31>r Loabus Pre "Lean-To Shed" Impervious Surface Calculation Formula 1,063 sf • Calculate the square footage of the followin• : 917 sf House Footprint 148 sf Driveways 61 sf Sidewalks 147 sf Walkways and Stepping Stones Detached Garages 0 sf Detached Sheds 1,085 sf Patios Decks ► 138 sf A/C Pads ► 10 sf Pool Decking and Water(50%credit for Water) ► 0 sf • Add the total square footage of the areas listed above, then divide the sum by the total lot area of the property. SUM: 3,569sf LOT: 5,500 sf Section 24-68(b) of the Land Development Regulations requires % 0.6a9 on-site storage for increased run-off if adding 250 square feet or more impervious surface. Provide Delta volume calculations and on-site retention required per Section 24-68(b). Delta Excess 19.9% Above 45% : • Impervious Surface & Property Set-Backs — Subject Property Case Study (Encl. 3) n-To Shed Footprint & Set-BackPLea k , ,. ,,,_ . ..........L . _ . . _ .. . . 0 c , . .. . . , .. . _ ._ . , , . , .... , . _ __ . . _ ___ 5' 1" I , _ , 1Aood S4,,, vt.i o if) 4,11 ,,,, et Back . ,__ . 1 7' 10„ I1/4Set Back �"14 6� 2�� X1 r� o CI) , 645{ . A - x 1:11 , . ,+'"- — — —► ` w al r • Set Back - %%A . ` 23 .... ..,, _ (41 . 41sf` sf r f is. gig" ..., e. ,,,, ., , ' Existing ' 0. Added Impervious .0 ..... Impervious (White) (Yellow) A14" Impervious Surface & Property Set-Backs — Subject Property Case Study (Encl. 3) TOPIC AREA: IMPERVIOUS SOLUTION 1 Solution: "DEMO OLD PAD — KEEP NEW ADD" RECLAIMED — PERVIOUS SOIL — 43. 98 sf DEMO 1980's Do: Pen Specs: 12' x 7' 11 `'. .:.' : + (-) 84sf L Non-Compliant set-:ac s *"" . . .\\ r 0 k . 1. xs (4.3 t � '` .\13 %., ,. Approve Slab Add I.S ,w � \ ' Specs: 32.72 + 6.5 + 1.8 sf t r 1 1 L (+) 41 sf i ...s... ill q, % 1 At Compliant Set-Backs t / 4 Y45tra la ( t 4. #► I ,....4......., , I t 4"." t L I Vii 6 : `� „,,0400444414L, ''w t 'p t,ft.�„+ 0 \ 11 ill ,I l I . i ) n AI 0 -0 5Y _ sY O A- o 11 3 1 Construction of Lean-To Shed fD cp Q Cu (2) Slab & Footer Notes N 0 0 CO I. m (A) New Impervious Slab 41.02sf @ 3” thick on 2" Crush _ 4 Sakrete High Strength Concrete Mix • -, (C) Entire Pan Pour r - (B) Footer 1" thick f �4" W x 3" H Sakrete Crack Resistant Cdncrete Tapcon 3" sub-Anchors + Interior Floor Leveler Sakrete Crack Resistant Concrete Mix 4 1'; 4 V) (E) Mud Sill -o 4 / 9" _f ham, 11PT#2,Prime o lk . */ o (D) Vapor Barrier (F) Anchors Note: 30# Felt Tapcon 3 pre-existing Cracks Washers Numerous o 3 Mud Sill & Anchor Notes CD 4 Framin: NotesCO 0 Y �J • -t-, 'f • O 00 • .'.,.. ;. %� (H.1) Ledger Board _.. a ; •:} 4' ii to Garage Studs O1 / ._ ;- _ _ 3" Grip-Rite SS screws o ' 2.5" Rini, Shank Coils rN) 1141iti 'I .,%41:,J L s 14\ - - ' j F ...„ I r\ '" (H.2) Framing - G Shed to Garage Dbl Sill Plate - 16D Vapor Barrier, Spax: .5 x 6" + 16" OC Studs HeadLOK 4.5" + 16D Nails 16D & 2.5" Ring Shank Coils ( I ) Rafters Dbl Top Sill - 16D 41-/ K -,.. 11 Rafters - 12" OC Z''N} 2 Barge Rafters -7.5" OC k Bird Mouth - HeadLOK 4.5" 3:12 Pitch - 14deg - Flat 1` °° ' '~' Soffit Vents �, � ._, t.• f "a (J) Frame Sheathing `� .5" GP Plywood Staggered Joints ,� ' 2.5" Rin• Shank Coils v' (K) Roof Sheathing o 'ter Loctite PL Premium Adhesive -o . 5/8" GP Plywood 0 Staggered Joints i 2.5" Rin. n Shank Coils ,frim o n fi OA 0 5 Rafter & Sheathin : Notes ri- cp 0_ (6) Rafter Hanging Notes a) a Note: Existin. Gara•e Soffit -' 0 •N al N 0 N NJ i� m t m • (L) Rafter Hanging Ledger Simpson Hangers = "a 2x6 Support Hanger— '4" Spax 6" Lag-Screws Ili oR' ti 16D Nails Grip-Rite SS Screws 9 t Note: Existin• Garage Sheathin• (N) Roofing (0) Step-Flashing GAF Liberty SBS Self-Adhering Cap Sheet Flashing Cement & Fasteners Single-Ply System Procedures D41 Asphalt Primer & Flashing Cement 4'. ' 4 ,. �' a Tr 1 ;; 11 .. s` (M) Drip-Edge Flashing Flashing Cement & Fasteners ' ' I it Fascia r `• 0 � , F s�'l { 0 11 ' (D (P) Siding o - #30 Felt Vapor Barrier Cedar Shingle o Note: No External Shed Openings. Weaved Corners '- Access from Garage Interior Only. 1 .5" 4d SS Siding Nails or) 1.5" Rin. Shank Coils 3 7 Roof S stem Notes CL 8 Rake & Eave Notes cu v; •1 �:. , < , .....1o 0 A. . _ . f .. o0 -.. 1 / iv ` C) . - '� �/ L .. o . m •A (Q) Rake & Eave Rake: 7.5" OC Over-Hang Extended Top-Plate & Barge Rafter • I Eave: 12" Over-Hang 12" OC Bird's Mouth Rafters Soffit Ventilation +�' Scope-of-Work Completed as of 08.26.2022 (Encl. 4) { x \ _ n v r a, M r ,L . _ .0 I, MOII r. leassitopellf .1.11111111141.1111! 1 ' ' r (S) Lean-To Shed SPECS 6' 2" W x 10' 4" L (63.72sf) • dQ Ht: 72.5" Front / 89" Back fi ''''''` Flat Pitch - 3:12 - 14deg R O enin L Dbl Sills - Dbl Plates - � Staggered Joints Garage Frame � a. '' Triple Corner Studs 18.5" W Opening Dbl King Studs 16" OC Studs .: -_ 12" OC Rafters 21 .5" OC _ No Header No Exterior Openings 1.4.ry/ ".1n... FI, yK.ayk c- V`441. `4 .. ".1404,461 ,_- — v 9 O .enin : Notes 10 Shed SPECS Notes