Loading...
475 Sargo Rd ROOF22-0045 2nd submittal - additional informationROOF22-0045 50.00 Information submitted was not highlighted as requested. Spoke to individual on the phone.First review comments described what needed to be highlighted. By Mike Jones at 8:58 am, Aug 22, 2022 FL2533-R19 FRSA Self Insurers Fund 01/01/2023 ROOF22-0045 EXTERIOR RESEARCH & DESIGN, LLC. Certificate of Authorization #9503 353 Christian Street Oxford, CT 06478 (203) 262-9245 EVALUATION REPORT CertainTeed Corporation 20 Moores Road Malvern, PA 19355 (610) 651-5847 Evaluation Report 3520.03.04-R20 FL2533-R19 Date of Issuance: 09/19/2005 Revision 20: 09/14/2017 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code. The product described herein has been evaluated for compliance with the 6th Edition (2017) Florida Building Code sections noted herein. DESCRIPTION: Flintlastic® Modified Bitumen Roof Systems LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. Trinity|ERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the ǁords ͞Trinity | ERD Evaluated͟ maLJ be displaLJed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 6, plus a 57-page Appendix. Prepared by: Robert J.M. Nieminen, P.E. Florida Registration No. 59166, Florida DCA ANE1983 The facsimile seal appearing was authorized by Robert Nieminen, P.E. on 09/14/2017. This does not serve as an electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. Exterior Research & Design, LLC. d/b/a Trinity | ERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Exterior Research & Design, LLC. d/b/a Trinity | ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither Trinity|ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. Exterior Research and Design, LLC. Evaluation Report 3520.03.04-R20 Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION FL2533-R19 CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 651-5847 Revision 20: 09/14/2017 Page 2 of 6 ROOFING SYSTEMS EVALUATION: 1. SCOPE: Product Category: Roofing Sub-Category: Modified Bitumen Roof Systems Compliance Statement: Flintlastic® Modified Bitumen Roof Systems, as produced by CertainTeed Corporation, have demonstrated compliance with the following sections of the 6th Edition (2017) Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1504.3.1 Wind FM 4474 2011 1504.7 Impact FM 4470 2012 1507.11.2 Physical Properties ASTM D6162 2008 1507.11.2 Physical Properties ASTM D6163 2008 1507.11.2 Physical Properties ASTM D6164 2011 1507.11.2 Physical Properties ASTM D6222 2011 1507.11.2 Physical Properties ASTM D6509 2009 3. REFERENCES: Entity Examination Reference Date ERD (TST6049) FM 4470 3504.06.01-1 06/05/2001 ERD (TST6049) FM 4470 3513.08.02 08/15/2002 ERD (TST6049) FM 4470 03515.07.03 07/22/2003 ERD (TST6049) FM 4470 3519.12.03 12/22/2003 ERD (TST6049) FM 4470/4474 3522.07.04 07/28/2004 ERD (TST6049) FM 4470/4474 02843.02.05-11 02/10/2005 ERD (TST6049) FM 4470/4474 3533.01.06 01/06/2006 ERD (TST6049) FM 4470/4474 4674.11.01-1 03/21/2006 ERD (TST6049) Physical Properties 3535.10.06 10/31/2006 ERD (TST6049) FM 4470/4474 3521.07.04-R1 10/26/2007 ERD (TST6049) FM 4470/4474 02764.09.05-R1 12/10/2007 ERD (TST6049) FM 4470/4474 02762.03.05-R1 12/10/2007 ERD (TST6049) Physical Properties C7290.01.08 01/16/2008 ERD (TST6049) Physical Properties C10080.09.08 09/04/2008 ERD (TST6049) FM 4470/4474 C8370.08.08-R1 10/05/2009 ERD (TST6049) FM 4470/4474 P6860.06.07-R1 09/10/2009 ERD (TST6049) FM 4470/4474 C30310.12.09 12/17/2009 ERD (TST6049) FM 4470/4474 C30560.03.10 03/18/2010 ERD (TST6049) FM 4470/4474 C31420.08.10 09/21/2010 ERD (TST6049) FM 4470/4474 C33980.12.10 12/22/2010 ERD (TST6049) FM 4470/4474 C33830.02.11 02/08/2011 ERD (TST6049) TAS 117(B), Rupture C35500.02.11 02/09/2011 ERD (TST6049) FM 4470/4474 C37820.07.12 07/24/2012 ERD (TST6049) FM 4470/4474 C37830.07.12 07/26/2012 ERD (TST6049) Physical Properties C42110.08.12 08/13/2012 ERD (TST6049) FM 4470/4474 C39670.08.12 08/20/2012 ERD (TST6049) FM 4470/4474 C42280.08.12 08/20/2012 ERD (TST6049) TAS 117(A) A35880.04.12-R1 10/26/2012 ERD (TST6049) FM 4470/4474 C44580.07.13 07/25/2013 ERD (TST6049) FM 4470/4474 C46090.11.13-A 11/20/2013 ERD (TST6049) FM 4470/4474 C45620.03.14 03/27/2014 ERD (TST6049) FM 4470/4474 C46760.06.14 06/19/2014 ERD (TST6049) FM 4470/4474 C47320.03.14-R1 04/01/2015 ERD (TST6049) FM 4470/4474 CTR-SC8995.10.15 10/14/2015 ERD (TST6049) FM 4470/4474 CTR-SC9935.01.16 01/14/2016 ERD (TST6049) FM 4470 CTR-SC9920.01.16-R1 01/20/2016 ERD (TST6049) FM 4470/4474 CTR-SC10420.01.16 01/25/2016 ERD (TST6049) FM 4470/4474 CTR-SC9175.09.16-1 09/06/2016 Exterior Research and Design, LLC. Evaluation Report 3520.03.04-R20 Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION FL2533-R19 CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 651-5847 Revision 20: 09/14/2017 Page 3 of 6 Entity Examination Reference Date ERD (TST6049) FM 4470/4474 CTR-SC9175.09.16-1 09/06/2016 ERD (TST6049) FM 4470/4474 CTR-SC11590.08.16-R1 09/06/2016 ERD (TST6049) FM 4470/4474 CTR-SC12255.12.16 12/27/2016 ERD (TST6049) FM 4474 CRT-SC15775.17 09/13/2017 FM Approvals (TST1867) FM 4470 0E3A2.AM 03/30/1982 FM Approvals (TST1867) FM 4470 3W0A4.AM 03/16/1993 FM Approvals (TST1867) FM 4470 3W0A2.AM 03/17/1993 FM Approvals (TST1867) FM 4470 3W0A3.AM 03/17/1993 FM Approvals (TST1867) FM 4470 1Z4A6.AM 09/11/1996 FM Approvals (TST1867) FM 4470 3Y8A1.AM 09/30/1996 FM Approvals (TST1867) FM 4470 2D5A9.AM 06/22/1999 FM Approvals (TST1867) FM 4470 3009502 12/12/2000 FM Approvals (TST1867) FM 4470 3008869 03/19/2001 FM Approvals (TST1867) FM 4470 3009610 10/15/2001 FM Approvals (TST1867) FM 4470 3006025 12/28/2001 FM Approvals (TST1867) FM 4470 3012321 07/29/2002 FM Approvals (TST1867) FM 4470 3009814 09/06/2002 FM Approvals (TST1867) FM 4470 3014502 04/04/2003 FM Approvals (TST1867) FM 4470 3015444 07/11/2003 FM Approvals (TST1867) FM 4470 3014692 08/05/2003 FM Approvals (TST1867) FM 4470 3014751 08/27/2003 FM Approvals (TST1867) FM 4470 3018579 10/09/2003 FM Approvals (TST1867) FM 4470/4474 3020703 07/30/2004 FM Approvals (TST1867) FM 4470/4474 3021759 06/03/2005 FM Approvals (TST1867) FM 4470/4474 3022038 04/05/2006 FM Approvals (TST1867) FM 4470/4474 3023458 07/18/2006 FM Approvals (TST1867) FM 4470/4474 3026128 08/04/2006 FM Approvals (TST1867) FM 4470/4474 3024311 11/01/2006 FM Approvals (TST1867) FM 4470/4474 3025766 11/13/2006 FM Approvals (TST1867) FM 4470/4474 3028410 02/19/2007 FM Approvals (TST1867) FM 4470/4474 3026964 07/25/2007 FM Approvals (TST1867) FM 4470/4474 3031262 11/30/2007 FM Approvals (TST1867) FM 4470/4474 3031199 12/23/2008 FM Approvals (TST1867) FM 4470/4474 3032172 06/12/2009 FM Approvals (TST1867) FM 4470/4474 3037127 01/11/2010 FM Approvals (TST1867) FM 4470/4474 3039848 12/02/2011 FM Approvals (TST1867) FM 4470/4474 3046104 08/13/2013 FM Approvals (TST1867) FM 4470/4474 3048520 09/19/2013 MTI (TST2508) Physical properties DX08C4A 03/22/2004 MTI (TST2508) Physical properties DX20E3A 03/22/2004 MTI (TST2508) Physical properties DX20E3A-001 01/04/2006 MTI (TST2508) Physical properties AX31G8A 08/21/2008 MTI (TST2508) Physical properties AX31G8D 09/05/2008 MTI (TST2508) Physical properties AX31G8F 06/05/2009 MTI (TST2508) Physical properties AX21G8C 01/28/2011 PRI (TST5878) Physical Properties CTC-032-02-01 01/16/2008 PRI (TST5878) Physical Properties CTC-034-02-01 11/24/2008 PRI (TST5878) Physical Properties CTC-066-02-01 08/08/2011 PRI (TST5878) Physical Properties CTC-067-02-01 08/08/2011 PRI (TST5878) Physical Properties CTC-068-02-01 08/08/2011 PRI (TST5878) Physical Properties CTC-070-02-01 08/08/2011 PRI (TST5878) Physical Properties CTC-071-02-01 08/08/2011 PRI (TST5878) Physical Properties CTC-093-02-01 08/08/2011 PRI (TST5878) Physical Properties CTC-116-02-01 04/03/2012 PRI (TST5878) Physical Properties CTC-183-02-01 10/04/2013 PRI (TST5878) Physical Properties CTC-259-02-01 12/11/2015 UL, LLC. (QUA9625) Quality Assurance Service Confirmation, R11656 Exp. 03/09/2020 Exterior Research and Design, LLC. Evaluation Report 3520.03.04-R20 Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION FL2533-R19 CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 651-5847 Revision 20: 09/14/2017 Page 4 of 6 4. PRODUCT DESCRIPTION: This Evaluation Report covers Flintlastic® Modified Bitumen Roof Systems installed in accordance with CertainTeed Corporation published installation instructions and the Limitations / Conditions of Use herein. The following CertainTeed products make up the subject systems. TABLE 1: ROLL-GOODS FOR FLINTLASTIC® MODIFIED BITUMEN ROOF SYSTEMS Type Product Specification Reference Grade Type Base Sheets Flintlastic® SA NailBase ASTM D4601 N/A II GlasbaseΡ Base Sheet ASTM D4601 N/A II All WeatherͬEmpireΡ Base ASTM D4601 N/A II FledžiglasΡ Base ASTM D4601 N/A II FlintlasticΡ Base ϮϬ ASTM D4601 N/A II Flintlastic Poly SMS Base Sheet ASTM D4601 N/A II Yosemite® Venting Base ASTM D4897 N/A II Ply Sheets Flintglas® Ply 4 ASTM D2178 N/A IV Flintglas® Premium Ply 6 ASTM D2178 N/A VI Base/Ply Membranes (APP) Flintlastic® APP Base T ASTM D6509 N/A N/A Flintlastic® STA ASTM D6222 S I Flintlastic® STA Plus ASTM D6222 S I Cap Membranes (APP) Flintlastic® STA ASTM D6222 S I Flintlastic® STA Plus ASTM D6222 S I Flintlastic® GTA ASTM D6222 G I FlintlasticΠ GTA CoolStarΡ ASTM D6222 G I Flintlastic® GTA-FR ASTM D6222 G I Flintlastic® GTA-FR CoolStarΡ ASTM D6222 G I Base/Ply Membranes (SBS) Flintlastic® SA PlyBase ASTM D1970 N/A N/A Black Diamond® Base Sheet ASTM D1970 N/A N/A Flintlastic® SA Mid Ply ASTM D6163 S I Flintlastic® Ultra Glass SA ASTM D6163 S I Flintlastic® Base 20 ASTM D6163 S I Flintlastic® Base 20 T ASTM D6163 S I Flintlastic® Ultra Poly SMS Base Sheet ASTM D6164 S I Cap Membranes (SBS) Flintlastic® FR Dual Cap ASTM D6162 G I Flintlastic® SA Cap FR ASTM D6163 G I Flintlastic® SA Cap FR CoolStarΡ ASTM D6163 G I Flintlastic® Cap 30 ASTM D6163 G I Flintlastic® Cap 30 CoolStarΡ ASTM D6163 G I Flintlastic® FR Cap 30 ASTM D6163 G I Flintlastic® FR Cap ϯϬ CoolStarΡ ASTM D6163 G I Flintlastic® FR Cap 30 T ASTM D6163 G I Flintlastic® FR Cap ϯϬ T CoolStarΡ ASTM D6163 G I Flintlastic® SA Cap ASTM D6164 G I Flintlastic® SA Cap CoolStarΡ ASTM D6164 G I Flintlastic® FR-P ASTM D6164 G I Flintlastic® FR-P CoolStarΡ ASTM D6164 G I Flintlastic® GMS ASTM D6164 G I Flintlastic® GMS CoolStarΡ ASTM D6164 G I Flintlastic® GTS ASTM D6164 G II Flintlastic® GTS CoolStarΡ ASTM D6164 G II Flintlastic® GTS-FR ASTM D6164 G II Flintlastic® GTS-FR CoolStarΡ ASTM D6164 G II Flintlastic® Premium FR-P ASTM D6164 G II Flintlastic® Premium FR-P CoolStarΡ ASTM D6164 G II Exterior Research and Design, LLC. Evaluation Report 3520.03.04-R20 Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION FL2533-R19 CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 651-5847 Revision 20: 09/14/2017 Page 5 of 6 5. LIMITATIONS: 5.1 This is a building code evaluation. Neither Trinity|ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in HVHZ jurisdictions. 5.3 Refer to a current UL Roofing Materials Directory for fire ratings of this product. 5.4 For steel deck installations, foam plastic insulation shall be separated from the building interior in accordance with FBC 2603.4 unless the exceptions stated in FBC 2603.4.1 and 2603.6 apply. 5.5 The roof system evaluation herein pertains to above-deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation. 5.6 For recover installations, the existing roof shall be examined in accordance with FBC 1511. 5.7 For mechanically attached insulation or membrane or strip-bonded insulation, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC Chapter 16. Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29, Roofing Application Standard RAS 117 and Roofing Application Standard RAS 137. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (January 2016) for Zone 2/3 enhancements. 5.8 For assemblies with all components fully bonded in place, the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16. No rational analysis is permitted for these systems. 5.9 For mechanically attached insulation or membrane over existing roof decks, fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the minimum requirements for the system. Testing and analysis shall be in accordance with ANSI/SPRI FX-1 or Testing Application Standard TAS 105. 5.10 For bonded insulation or membrane over existing substrates in a re-roof (tear off) or recover installation, the existing deck or existing roof surface shall be examined for compatibility with the adhesive to be installed. If any surface conditions exist that bring system performance into question, field uplift testing in accordance with ANSI/SPRI IA-1, ASTM E907, FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124 shall be conducted on mock-ups of the proposed new roof assembly. 5.11 For bonded insulation or membrane over existing substrates in a recover installation, the existing roof system shall be capable of resisting project design pressures on its own merit to the satisfaction of the Authority Having Jurisdiction, as documented through field uplift testing in accordance with ASTM E907, FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124. 5.12 Metal edge attachment (except gutters), shall be designed and installed for wind loads in accordance with FBC Chapter 16 and tested for resistance in accordance with ANSI/SPRI ES-1 or Roofing Application Standard RAS 111, except the basic wind speed shall be determined from FBC Figure 1609.3(1), 1609.3(2) or 1609.3(3). 5.13 All products in the roof assembly shall have quality assurance in accordance with FAC Rule 61G20-3. Exterior Research and Design, LLC. Evaluation Report 3520.03.04-R20 Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION FL2533-R19 CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 651-5847 Revision 20: 09/14/2017 Page 6 of 6 6. INSTALLATION: 6.1 Flintlastic® Modified Bitumen Roof Systems shall be installed in accordance with CertainTeed Corporation published installation instructions, subject to the Limitations / Conditions of Use herein. 6.2 System attachment requirements for wind load resistance are set forth in Appendix 1. ͟MDP͟ с Madžimum Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FBC 1609 for determination of design wind loads. 7. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 8. MANUFACTURING PLANTS: Contact the named QA entity for manufacturing facilities covered by F.A.C. Rule 61G20-3 QA requirements. 9. QUALITY ASSURANCE ENTITY: UL, LLC. ʹ QUA9625; (414) 248-6409, karen.buchmann@us.ul.com - THE 57-PAGES THAT FOLLOW FORM PART OF THIS EVALUATION REPORT - Exterior Research and Design, LLC. d/b/a Trinity|ERD Evaluation Report 3520.03.04-R20 for FL2533-R19 Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 20: 09/14/2017 Prepared by: Robert Nieminen, PE-59166 CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 651-5847 Appendix 1, Page 1 of 57 APPENDIX 1: ATTACHMENT REQUIREMENTS FOR WIND UPLIFT RESISTANCE Table Deck Application Type Description Page 1A Wood New or Reroof (Tear-Off) A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 5-6 1B Wood New, Reroof (Tear-Off) or Recover B Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 7 1C Wood New, Reroof (Tear-Off) or Recover C Mech. Attached Insulation, Bonded Roof Cover 8-9 1D Wood New, Reroof (Tear-Off) or Recover D Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 10-12 1E-1 Wood New, Reroof (Tear-Off) E Non-Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 13-15 1E-2 Wood New, Reroof (Tear-Off) or Recover E Non-Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 16-17 1F Wood New or Reroof (Tear-Off) F Non-Insulated, Bonded Roof Cover 17 2A Steel or Structural Concrete New, Reroof (Tear-Off) or Recover B Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 18-20 2B Steel or Structural Concrete New, Reroof (Tear-Off) or Recover C Mech. Attached Insulation, Bonded Roof Cover 21-25 2C Steel or Structural Concrete New, Reroof (Tear-Off) or Recover D Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 26-28 3A Concrete New or Reroof (Tear-Off) A-1 Bonded Insulation, Bonded Roof Cover 29-36 3B Concrete New or Reroof (Tear-Off) A-3 Bonded Temp Roof/Vapor Barrier, Bonded Insulation, Bonded Roof Cover 36 3C Concrete New or Reroof (Tear-Off) F Non-Insulated, Bonded Roof Cover 37 4A LWIC New or Reroof (Tear-Off) A-1 Bonded Insulation, Bonded Roof Cover 38-39 4B LWIC New or Reroof (Tear-Off) A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 40 4C LWIC New, Reroof (Tear-Off) E Non-Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 41-44 5A CWF New or Reroof (Tear-Off) A-1 Bonded Insulation, Bonded Roof Cover 45 5B CWF New or Reroof (Tear-Off) A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 46 5C CWF New, Reroof (Tear-Off) or Recover C Mech. Attached Insulation, Bonded Roof Cover 46 5D CWF New, Reroof (Tear-Off) E Non-Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 47 6A Gypsum Reroof (Tear-Off) A-1 Bonded Insulation, Bonded Roof Cover 48-49 6B Gypsum Reroof (Tear-Off) A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 50 6C Gypsum Reroof (Tear-Off) C Mech. Attached Insulation, Bonded Roof Cover 51 6D Gypsum Reroof (Tear-Off) E Non-Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 51 7A Various Recover A-1 Bonded Insulation, Bonded Roof Cover 52-57 7B Various Recover F Non-Insulated, Bonded Roof Cover 57 The following notes apply to the systems outlined herein: 1. The roof system evaluation herein pertains to above-deck roof components. Roof decks shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation. 2. Unless otherwise noted, fasteners and stress plates for insulation attachment shall be as follows. Fasteners shall be of sufficient length for the following engagements: ¾ Wood Deck: OMG #14 Roofgrip with Flat Bottom Plate (Accutrac), OMG HD with OMG 3 in. Galvalume Steel Plate͕ Dekfast ηϭϰ ǁith Hedž Plate or ϯ͟ RoƵnd InsƵlation Plate, Trufast HD with TrƵfast ϯ͟ Metal Insulation Plates or FlintFast ηϭϰ Fastener ǁith FlintFast ϯ͟ InsƵlation Plates. Minimum 0.75-inch plywood penetration or minimum 1-inch wood plank embedment. ¾ Steel Deck: OMG #12 or #14 Roofgrip with Recessed or Flat Bottom Plate (Accutrac), OMG #12 Standard or HD with OMG 3 in. Galvalume Steel Plate͕ Dekfast ηϭϮ or ηϭϰ ǁith Hedž Plate or ϯ͟ RoƵnd Insulation Plate, Trufast DP or HD with TrƵfast ϯ͟ Metal InsƵlation Plates or FlintFast ηϭϮ or ηϭϰ Fastener ǁith FlintFast ϯ͟ Insulation Plates. Minimum 0.75-inch steel penetration and engage the top flute of the steel deck. ¾ Structural Concrete: OMG #14 Roofgrip with Recessed or Flat Bottom Plate (Accutrac), OMG HD or CD-10 with OMG 3 in. Galvalume Steel Plate, Dekfast #14 or DekSpike ǁith Hedž Plate or ϯ͟ RoƵnd Insulation Plate, Trufast HD or CF with TrƵfast ϯ͟ Metal InsƵlation Plates or FlintFast ηϭϰ Fastener ǁith FlintFast ϯ͟ InsƵlation Plates. Minimum 1-inch embedment. Fasteners installed with a pilot hole in accordance with the fastener manƵfactƵrer͛s pƵblished installation instrƵctions. Exterior Research and Design, LLC. d/b/a Trinity|ERD Evaluation Report 3520.03.04-R20 for FL2533-R19 Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 20: 09/14/2017 Prepared by: Robert Nieminen, PE-59166 CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 651-5847 Appendix 1, Page 2 of 57 3. Unless otherwise noted, insulation may be any one layer or combination of polyisocyanurate, polystyrene, wood fiberboard, perlite, GlasRoc Roof Board or gypsum-based roof board that meets the QA requirements of F.A.C. Rule 61G20-3 and is documented as meeting FBC 1505.1 and, for foam plastic, FBC Chapter 26, when installed with the roof cover. 4. Minimum 200 psi, minimum 2-inch thick lightweight insulating concrete may be substituted for, or installed beneath rigid insulation board for System Type D (mechanically attached base sheet, bonded roof cover), whereby the base sheet screws and plates are installed through the LWIC to engage the structural steel or concrete deck. The structural deck shall be of equal or greater configuration to the steel and concrete deck listings. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation. 5. Preliminary insulation attachment for System Type D: Unless otherwise noted, refer to Section 2.2.10.1.3 of FM Loss Prevention Data Sheet 1-29 (January 2016). 6. Unless otherwise noted, insulation adhesive application rates are as follows. Ribbon or bead width is at the time of application; the ribbons/beads shall edžpand as noted in the manƵfactƵrer͛s pƵblished instrƵctions͘ ¾ Hot asphalt (HA): Full coverage at 25-30 lbs/square ¾ Ashland Pliodeck (A-PD): Continuous 0.75 inch wide ribbons, 12-inch o.c. Ribbons of subsequent layers shall be perpendicular to those in the layer below. ¾ Dow INSTA-STIK Quik Set Insulation Adhesive (D-IS): Continuous 0.75 to 1 inch wide ribbons, 12-inch o.c. ¾ Millennium One Step Foamable Adhesive (M-OSFA): Continuous 0.25 to 0.5-inch wide ribbons, 12-inch o.c. ¾ Millennium PG-1 Pump Grade Adhesive (M-PG1): Continuous 0.5 to 0.75-inch wide ribbons, 12-inch o.c. ¾ OMG OlyBond 500 or OlyBond Green (OB500): Continuous 0.75-inch wide ribbons, 12-inch o.c. (PaceCart or SpotShot) ¾ ICP Adhesives CR-20: Continuous 2.5 to 3-inch wide ribbons, 12-inch o.c. ¾ Note: When multiple layers(s) of insulation and/or coverboard are installed in ribbon-applied adhesive, boards shall be staggered from layer-to-layer. ¾ Note: The maximum edge distance from the adhesive ribbon to the edge of the insulation board shall be not less than one-half the specified ribbons spacing. 7. Unless otherwise noted, all insulations are flat-stock or taper board of the minimum thickness noted. Tapered polyisocyanurate at the following thickness limitations may be substituted with the following Maximum Design Pressure (MDP) limitations͘ In no case shall these ǀalƵes be Ƶsed to ͚increase͛ the MDP listings in the tables; rather if MDP listing below meets or exceeds that listed for a particular system in the tables, then the thinner board listed below may be used as a drop-in for the equivalent thicker material listed in the table: ¾ Ashland Pliodeck (A-PD) @ 12-inch o.c. MDP -105.0 psf (Min. 1.0-inch) ¾ Ashland Pliodeck (A-PD) @ 6-inch o.c. MDP -277.5 psf (Min. 1.0-inch) ¾ Dow INSTA-STIK Quik Set Insulation Adhesive (D-IS): MDP -120.0 psf (Min. 1.0-inch) ¾ Millennium One Step Foamable Adhesive (M-OSFA): MDP -157.5 psf (Min. 1.0-inch) ¾ Millennium PG-1 Pump Grade Adhesive (M-PG1): MDP -157.5 psf (Min. 1.0-inch) ¾ OMG OlyBond 500 (OB500): MDP -45.0 psf (Min. 0.5-inch Multi-Max FA3) ¾ OMG OlyBond 500 (OB500): MDP -187.5 psf (Min. 0.5-inch ISO 95+ GL) ¾ OMG OlyBond 500 (OB500): MDP -315.0 psf (Min. 0.5-inch ENRGY 3) ¾ OMG OlyBond 500 (OB500): MDP -487.5 psf (Min. 0.5-inch ACFoam II) ¾ ICP Adhesives CR-20: MDP -117.5 psf (Min. 1.0-inch) 8. Bonded polyisocyanurate insulation boards shall be maximum 4 x 4 ft. 9. For mechanically attached components or partially bonded insulation, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC Chapter 16, and Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29 and Roofing Application Standard RAS 117. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (January 2016) for Zone 2/3 enhancements. 10. For assemblies with all components fully bonded in place, the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16, and no rational analysis is permitted. 11. For mechanically attached components over existing decks, fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the minimum requirements for the system. Testing and analysis shall be in accordance with ANSI/SPRI FX-1 or Testing Application Standard TAS 105. Exterior Research and Design, LLC. d/b/a Trinity|ERD Evaluation Report 3520.03.04-R20 for FL2533-R19 Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 20: 09/14/2017 Prepared by: Robert Nieminen, PE-59166 CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 651-5847 Appendix 1, Page 3 of 57 12. For existing substrates in a bonded recover or re-roof installation, the existing roof surface or existing roof deck shall be examined for compatibility and bond performance with the selected adhesive, and the existing roof system (for recover) shall be capable of resisting project design pressures on its own merit to the satisfaction of the Authority Having Jurisdiction, as documented through field uplift testing in accordance with ANSI/SPRI IA-1, ASTM E907, FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124. 13. For Concrete Deck or Recover Applications using System Type D, the insulation is optional. 14. Lightweight Insulating Concrete (LWC) shall be cast in accordance with FBC Section 1917 to the satisfaction of the Authority Having Jurisdiction. For systems where specific LWC is referenced, refer to current LWC Product Approval for specific deck construction and limitations. For systems where specific LWC is not referenced, the minimum design mix shall be 300 psi. In all cases, the minimum top-coat thickness is 2-inches. For LWC over structural concrete, reference is made to FBC Section 1917.4.1, Point 1 15. Unless otherwise noted, refer to the following references for bonded base, ply or cap sheet applications. CERTAINTEED FLINTLASTIC® MODIFIED BITUMEN COMPONENTS & APPLICATION METHODS Reference Layer Material Application BP-AA (Base and Ply sheets, Asphalt-Applied) Base Glasbase; All Weather/Empire Base; Flexiglas Base; Flintlastic Base 20 Hot asphalt at 20-40 lbs/square Ply One or more Flintglas Ply 4; Flintglas Premium Ply 6 BP-AA2 (Base, Spot-Asphalt-Applied) Base Yosemite Venting Base Hot asphalt in 24-inch diameter spots in 30-inch grid pattern BP-AA3 (Base, Spot-Asphalt-Applied) Base Yosemite Venting Base Hot asphalt in 9-inch diameter spots in grid pattern noted herein. BP-AA4 (Base, Strip-Asphalt-Applied) Base Yosemite Venting Base Hot asphalt in 9-inch wide ribbons spaced as noted herein. BP-CA2 Base/Ply Glasbase; All Weather/Empire Base; Flexiglas Base; Flintlastic Base 20 Henry #903 Adhesive at 1.5 gal/square BP-CA3 Base/Ply Glasbase; All Weather/Empire Base; Flexiglas Base; Flintlastic Base 20 Millennium Hurricane Force Membrane Adhesive, beads spaced 6-inch o.c. SBS-AA (SBS, Asphalt-Applied) Base Flintlastic Base 20; Flintlastic Poly SMS Base; Flintlastic Ultra Poly SMS Base Hot asphalt at 20-40 lbs/square Ply One or more Flintlastic Base 20; Flintlastic Poly SMS Base; Flintlastic Ultra Poly SMS Base Cap Flintlastic Cap 30; Flintlastic Cap 30 CoolStar; Flintlastic FR Cap 30; Flintlastic FR Cap 30 CoolStar; Flintlastic FR Dual Cap; Flintlastic FR-P; Flintlastic FR-P CoolStar; Flintlastic Premium FR-P; Flintlastic Premium FR-P CoolStar; Flintlastic GMS; Flintlastic GMS CoolStar SBS-CA1 (SBS, Cold-Applied) Base Flintlastic Base 20; Flintlastic Poly SMS Base; Flintlastic Ultra Poly SMS Base FlintBond Brush or Karnak No. 81 Cold Process Modified Bitumen Adhesive Brush Grade at 1 gal/square Note: Base ply cures overnight prior to application of the ply or cap ply. Ply Flintlastic Base 20; Flintlastic Poly SMS Base; Flintlastic Ultra Poly SMS Base Cap Flintlastic FR Cap 30; Flintlastic FR Cap 30 CoolStar; Flintlastic FR Dual Cap; Flintlastic FR-P; Flintlastic FR-P CoolStar; Flintlastic Premium FR-P; Flintlastic Premium FR-P CoolStar; Flintlastic GMS; Flintlastic GMS CoolStar SBS-CA2 (SBS, Cold-Applied) Base Flintlastic Base 20; Flintlastic Poly SMS Base; Flintlastic Ultra Poly SMS Base Henry #903 Adhesive at 1.5 gal/square. Ply Flintlastic Base 20; Flintlastic Poly SMS Base; Flintlastic Ultra Poly SMS Base Cap Flintlastic Cap 30; Flintlastic Cap 30 CoolStar; Flintlastic FR Cap 30; Flintlastic FR Cap 30 CoolStar; Flintlastic FR Dual Cap; Flintlastic FR-P; Flintlastic FR-P CoolStar; Flintlastic Premium FR-P; Flintlastic Premium FR-P CoolStar; Flintlastic GMS; Flintlastic GMS CoolStar Exterior Research and Design, LLC. d/b/a Trinity|ERD Evaluation Report 3520.03.04-R20 for FL2533-R19 Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 20: 09/14/2017 Prepared by: Robert Nieminen, PE-59166 CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 651-5847 Appendix 1, Page 4 of 57 CERTAINTEED FLINTLASTIC® MODIFIED BITUMEN COMPONENTS & APPLICATION METHODS (CONTINUED) Reference Layer Material Application SBS-CA3 (SBS, Cold-Applied) Base Flintlastic Base 20; Flintlastic Poly SMS Base; Flintlastic Ultra Poly SMS Base Millennium Hurricane Force Membrane Adhesive, beads spaced 6-inch o.c. Ply Flintlastic Base 20; Flintlastic Poly SMS Base; Flintlastic Ultra Poly SMS Base Cap Flintlastic Cap 30; Flintlastic Cap 30 CoolStar; Flintlastic FR Cap 30; Flintlastic FR Cap 30 CoolStar; Flintlastic FR Dual Cap; Flintlastic FR-P; Flintlastic FR-P CoolStar; Flintlastic Premium FR-P; Flintlastic Premium FR-P CoolStar; Flintlastic GMS; Flintlastic GMS CoolStar SBS-TA (SBS, Torch-Applied) Base Flintlastic Ultra Poly SMS Base; Flintlastic Base 20 T Torch-Applied Ply One or more Flintlastic Ultra Poly SMS Base; Flintlastic Base 20 T Cap Flintlastic FR Cap 30 T; Flintlastic FR Cap 30 T CoolStar; Flintlastic GTS; Flintlastic GTS CoolStar; Flintlastic GTS-FR; Flintlastic GTS-FR CoolStar; FlintClad APP-TA (APP, Torch-Applied) Base One or more Flintlastic APP Base T; Flintlastic STA; Flintlastic STA Plus Torch-Applied Cap Flintlastic STA; Flintlastic STA Plus; Flintlastic GTA; Flintlastic GTA CoolStar; Flintlastic GTA-FR; Flintlastic GTA-FR CoolStar SBS-SA-H (SBS, Self-Adhering, Hybrid Systems) Base/Ply Black Diamond Base Sheet; Flintlastic Ultra Glass SA Self-Adhering SBS-SA (SBS, Self-Adhering) Base Flintlastic SA PlyBase; Flintlastic SA Mid Ply Self-Adhering Ply Flintlastic SA PlyBase; Flintlastic SA Mid Ply Cap Flintlastic SA Cap; Flintlastic SA Cap CoolStar; Flintlastic SA Cap FR; Flintlastic SA Cap FR CoolStar 16. ͟MDP͟ с MadžimƵm Design PressƵre is the resƵlt of testing for ǁind load resistance based on alloǁable ǁind loads͘ Refer to FBC 1609 for determination of design wind loads. Exterior Research and Design, LLC. d/b/a Trinity|ERD Evaluation Report 3520.03.04-R20 for FL2533-R19 Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 20: 09/14/2017 Prepared by: Robert Nieminen, PE-59166 CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 651-5847 Appendix 1, Page 5 of 57 TABLE 1A: WOOD DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER Sys. No. Deck (Note 1) Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 14) MDP (psf) Type Fasteners Attach Type Attach Type Attach Base Ply Cap SELF-ADHERING SYSTEMS: W-1 Min. 19/32-inch plywood at max. 24-inch spans Glasbase, All Weather Empire, Flexiglas Base, Flintlastic Base 20; Poly SMS; Ultra Poly SMS; Yosemite 32 ga., 1-5/8-inch dia. tin caps with 11 ga. annular ring shank nails 9-inch o.c. in 4-inch lap and 12-inch o.c. in two (2), equally spaced, staggered center rows Min. 1.5-inch ACFoam II, FlintBoard ISO, ENRGY-3, H-Shield or Multi-Max FA3 HA Min. 0.25-inch Dens Deck primed with FlintPrime or FlintPrime SA HA SBS-SA (Optional) SBS-SA SBS-SA -45.0* W-2 Min. 19/32-inch plywood at max. 24-inch spans Glasbase, All Weather Empire, Flexiglas Base, Poly SMS or Ultra Poly SMS 32 ga., 1-5/8-inch dia. tin caps with 11 ga. annular ring shank nails 8-inch o.c. in 3-inch lap and 8-inch o.c. in three (3), equally spaced, staggered center rows Min. 1.5-inch ACFoam II, FlintBoard ISO, ENRGY-3, H-Shield or Multi-Max FA3 HA full coverage or OB500, M-OSFA, A-PD, D-IS or CR-20, 4-inch o.c. Min. 0.25-inch Dens Deck primed with FlintPrime or FlintPrime SA HA full coverage or OB500, M-OSFA, A-PD, D-IS or CR-20, 6-inch o.c. SBS-SA (Optional) SBS-SA SBS-SA -52.5 W-3 Min. 19/32-inch plywood at max. 24-inch spans Yosemite Venting Base Sheet 32 ga., 1-5/8-inch dia. tin caps with 11 ga. annular ring shank nails 8-inch o.c. in 3-inch lap and 8-inch o.c. in three (3), equally spaced, staggered center rows Min. 1.5-inch ACFoam II, FlintBoard ISO, ENRGY-3, H-Shield or Multi-Max FA3 HA Min. 0.25-inch Dens Deck primed with FlintPrime or FlintPrime SA HA SBS-SA (Optional) SBS-SA SBS-SA -52.5 W-4 Min. 19/32-inch plywood at max. 24-inch spans Glasbase, All Weather Empire, Flexiglas Base, Poly SMS or Ultra Poly SMS 32 ga., 1-5/8-inch dia. tin caps with 11 ga. annular ring shank nails 8-inch o.c. in 3-inch lap and 8-inch o.c. in three (3), equally spaced, staggered center rows (Optional) Min. 1.5-inch ACFoam II, FlintBoard ISO, ENRGY-3, H-Shield or Multi-Max FA3 HA full coverage or OB500, M-OSFA, A-PD, D-IS or CR-20, 4-inch o.c. Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board primed with FlintPrime or FlintPrime SA HA full coverage or OB500, M-OSFA, A-PD, D-IS or CR-20, 6-inch o.c. SBS-SA (Optional) SBS-SA SBS-SA -60.0 W-5 Min. 19/32-inch plywood at max. 24-inch spans Yosemite Venting Base Sheet 32 ga., 1-5/8-inch dia. tin caps with 11 ga. annular ring shank nails 8-inch o.c. in 3-inch lap and 8-inch o.c. in three (3), equally spaced, staggered center rows (Optional) Min. 1.5-inch ACFoam II, FlintBoard ISO, ENRGY-3, H-Shield or Multi-Max FA3 HA Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board primed with FlintPrime or FlintPrime SA HA SBS-SA (Optional) SBS-SA SBS-SA -60.0 HYBRID SYSTEMS: W-6 Min. 19/32-inch plywood at max. 24-inch spans Glasbase, All Weather Empire, Flexiglas Base, Flintlastic Base 20; Poly SMS; Ultra Poly SMS; Yosemite 32 ga., 1-5/8-inch dia. tin caps with 11 ga. annular ring shank nails 9-inch o.c. in 4-inch lap and 12-inch o.c. in two (2), equally spaced, staggered center rows Min. 1.5-inch ACFoam II, FlintBoard ISO, ENRGY-3, H-Shield or Multi-Max FA3 HA None N/A SBS-SA-H (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -45.0* Exterior Research and Design, LLC. d/b/a Trinity|ERD Evaluation Report 3520.03.04-R20 for FL2533-R19 Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 20: 09/14/2017 Prepared by: Robert Nieminen, PE-59166 CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 651-5847 Appendix 1, Page 6 of 57 TABLE 1A: WOOD DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER Sys. No. Deck (Note 1) Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 14) MDP (psf) Type Fasteners Attach Type Attach Type Attach Base Ply Cap W-7 Min. 19/32-inch plywood at max. 24-inch Glasbase; Flintglas Premium Ply 6; Yosemite 32 ga., 1-5/8-inch dia. tin caps with 11 ga. annular ring shank nails 8-inch o.c. in 3-inch lap and 8-inch o.c. in three (3), equally spaced, staggered center rows Min. 1.5-inch ACFoam II, FlintBoard ISO, ENRGY-3, H-Shield or Multi-Max FA3 HA None N/A SBS-SA-H (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -60.0 CONVENTIONAL SYSTEMS: W-8 Min. 19/32-inch plywood at max. 24-inch spans Glasbase, All Weather Empire, Flexiglas Base, Flintlastic Base 20; Poly SMS; Ultra Poly SMS; Yosemite 32 ga., 1-5/8-inch dia. tin caps with 11 ga. annular ring shank nails 9-inch o.c. in 4-inch lap and 12-inch o.c. in two (2), equally spaced, staggered center rows Min. 1.5-inch ACFoam II, FlintBoard ISO, ENRGY-3, H-Shield or Multi-Max FA3 HA Min. 0.25-inch Dens Deck primed with FlintPrime (ASTM D41) primer HA BP-AA, SBS-AA, SBS-TA or APP-TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -45.0* W-9 Min. 19/32-inch plywood at max. 24-inch spans Glasbase, All Weather Empire, Flexiglas Base, Poly SMS or Ultra Poly SMS 32 ga., 1-5/8-inch dia. tin caps with 11 ga. annular ring shank nails 8-inch o.c. in 3-inch lap and 8-inch o.c. in three (3), equally spaced, staggered center rows Min. 1.5-inch ACFoam II, FlintBoard ISO, ENRGY-3, H-Shield or Multi-Max FA3 HA full coverage or OB500, M-OSFA, A-PD, D-IS or CR-20, 4-inch o.c. Min. 0.25-inch Dens Deck primed with FlintPrime (ASTM D41) primer HA full coverage or OB500, M-OSFA, A-PD, D-IS or CR-20, 6-inch o.c. BP-AA, SBS-AA, SBS-TA or APP-TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -52.5 W-10 Min. 19/32-inch plywood at max. 24-inch spans Yosemite Venting Base Sheet 32 ga., 1-5/8-inch dia. tin caps with 11 ga. annular ring shank nails 8-inch o.c. in 3-inch lap and 8-inch o.c. in three (3), equally spaced, staggered center rows Min. 1.5-inch ACFoam II, FlintBoard ISO, ENRGY-3, H-Shield or Multi-Max FA3 HA Min. 0.25-inch Dens Deck primed with FlintPrime (ASTM D41) primer HA BP-AA, SBS-AA, SBS-TA or APP-TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -52.5 W-11 Min. 19/32-inch plywood at max. 24-inch spans Glasbase, All Weather Empire, Flexiglas Base, Poly SMS or Ultra Poly SMS 32 ga., 1-5/8-inch dia. tin caps with 11 ga. annular ring shank nails 8-inch o.c. in 3-inch lap and 8-inch o.c. in three (3), equally spaced, staggered center rows (Optional) Min. 1.5-inch ACFoam II, FlintBoard ISO, ENRGY-3, H-Shield or Multi-Max FA3 HA full coverage or OB500, M-OSFA, A-PD, D-IS or CR-20, 4-inch o.c. Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board HA full coverage or OB500, M-OSFA, A-PD, D-IS or CR-20, 6-inch o.c. BP-AA, SBS-AA, SBS-TA or APP-TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -60.0 W-12 Min. 19/32-inch plywood at max. 24-inch spans Yosemite Venting Base Sheet 32 ga., 1-5/8-inch dia. tin caps with 11 ga. annular ring shank nails 8-inch o.c. in 3-inch lap and 8-inch o.c. in three (3), equally spaced, staggered center rows (Optional) Min. 1.5-inch ACFoam II, FlintBoard ISO, ENRGY-3, H-Shield or Multi-Max FA3 HA Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board HA BP-AA, SBS-AA, SBS-TA or APP-TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -60.0 Exterior Research and Design, LLC. d/b/a Trinity|ERD Evaluation Report 3520.03.04-R20 for FL2533-R19 Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 20: 09/14/2017 Prepared by: Robert Nieminen, PE-59166 CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 651-5847 Appendix 1, Page 7 of 57 TABLE 1B: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE B: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer Top Insulation Layer Roof Cover (Note 14) MDP (psf) Type Fasteners Attach Type Attach Base Ply Cap HYBRID SYSTEMS: W-13 Min. 15/32-inch exterior grade plywood at max. 24-inch spans Min. 1.5-inch ACFoam II, FlintBoard ISO, H-Shield or FlintBoard ISOH. FlintFast #12 or #14 with FlintFast ϯ͟ Insulation Plates 1 per 1.33 ft2 Min. 1.5-inch ACFoam II, FlintBoard ISO, H-Shield or FlintBoard ISOH. HA, D-IS, M-OSFA, M-PG1 or OB500 SBS-SA-H (Optional) APP-TA APP-TA -67.5 CONVENTIONAL SYSTEMS: W-14 Min. 23/32-inch exterior grade plywood at max. 24-inch spans Min. 1.5-inch ACFoam II, FlintBoard ISO, ENRGY 3, H-Shield Note 2 1 per 2 ft2 Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation, min. 0.75-inch FescoBoard (homogeneous) HA BP-AA or SBS-AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -45.0* W-15 Min. 23/32-inch exterior grade plywood at max. 24-inch spans Min. 1.5-inch ACFoam II, FlintBoard ISO, ENRGY 3, H-Shield Note 2 1 per 2 ft2 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board, Dens Deck or Dens Deck Prime HA BP-AA, SBS-AA, SBS-TA or APP-TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -45.0* W-16 Min. 15/32-inch exterior grade plywood at max. 24-inch spans Min. 1.5-inch ACFoam II, FlintBoard ISO, H-Shield or FlintBoard ISOH. FlintFast #12 or #14 with FlintFast ϯ͟ Insulation Plates 1 per 1.33 ft2 Optional additional layer(s) of base insulation followed by Min. 0.25-inch SECUROCK Gypsum-Fiber Roof board HA, D-IS, M-OSFA, M-PG1 or OB500 APP-TA (Optional) APP-TA APP-TA -90.0 Exterior Research and Design, LLC. d/b/a Trinity|ERD Evaluation Report 3520.03.04-R20 for FL2533-R19 Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 20: 09/14/2017 Prepared by: Robert Nieminen, PE-59166 CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 651-5847 Appendix 1, Page 8 of 57 TABLE 1C: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE C: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer Top Insulation Layer Roof Cover (Note 14) MDP (psf) Type Fasteners Attach Base Ply Cap SELF-ADHERING SYSTEMS: W-17 Min. 15/32-inch plywood at max. 24-inch spans (Optional) One or more layers, any combination, loose laid Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Flintfast 3 in. Insulation Plates with FlintFast #12 or #14 1 per 3.2 ft2 SBS-SA (Optional) SBS-SA SBS-SA -30.0* W-18 Min. 19/32-inch exterior grade plywood at max. 24-inch spans (Optional) One or more layers, any combination, loose laid Min. 0.25-inch Dens Deck Note 2 1 per 1.33 ft2 Apply FlintPrime or FlintPrime SA to board & plates, followed by SBS-SA (Optional) SBS-SA SBS-SA -45.0 W-19 Min. 19/32-inch exterior grade plywood at max. 24-inch spans (Optional) One or more layers, any combination, loose laid Min. 3/8-inch SECUROCK Gypsum-Fiber Roof Board Flintfast 3 in. Insulation Plates with FlintFast #12 or #14 1 per 2.7 ft2 SBS-SA (Optional) SBS-SA SBS-SA -45.0* W-20 Min. 19/32-inch plywood at max. 24-inch spans (Optional) One or more layers, any combination, loose laid Min. 1.5-inch ACFoam II, ENRGY 3, H-Shield, Multi-Max FA3 or FlintBoard ISO Flintfast 3 in. Insulation Plates with FlintFast #12 or #14 1 per 2 ft2 Apply FlintPrime or FlintPrime SA to board & plates, followed by SBS-SA (Optional) SBS-SA SBS-SA -45.0* W-21 Min. 15/32-inch plywood at max. 24-inch spans (Optional) One or more layers, any combination, loose laid Min. 1.5-inch FlintBoard ISO FlintFast #14 HD with FlintFast ϯ͟ InsƵlation Plates or Trufast HD ǁith TrƵfast ϯ͟ Metal Insulation Plates 1 per 1.6 ft2 Apply FlintPrime to board & plates, followed by SBS-SA (Optional) SBS-SA SBS-SA -52.5 W-22 Min. 19/32-inch plywood at max. 24-inch spans (Optional) One or more layers, any combination, loose laid Min. 1.5-inch ACFoam II, ENRGY 3, H-Shield, Multi-Max FA3 or FlintBoard ISO Note 2 1 per 1.45 ft2 Apply FlintPrime or FlintPrime SA to board & plates, followed by SBS-SA (Optional) SBS-SA SBS-SA -60.0 HYBRID SYSTEMS: W-23 Min. 15/32-inch plywood at max. 24-inch spans (Optional) One or more layers, any combination, loose laid Min. 0.25-inch Dens Deck; Dens Deck Prime Flintfast 3 in. Insulation Plates with FlintFast #12 or #14 1 per 2 ft2 SBS-SA-H (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -30.0* W-24 Min. 15/32-inch plywood at max. 24-inch spans (Optional) One or more layers, any combination, loose laid Min. 1.5-inch FlintBoard ISO FlintFast #14 HD with FlintFast ϯ͟ InsƵlation Plates or Trufast HD ǁith TrƵfast ϯ͟ Metal Insulation Plates 1 per 1.6 ft2 SBS-SA-H (Optional) SBS-TA or APP-TA SBS-TA or APP-TA -52.5 W-25 Min. 15/32-inch plywood at max. 24-inch spans (Optional) One or more layers, any combination, loose laid Min. 1.5-inch ACFoam II, FlintBoard ISO, ENRGY 3 or Multi-Max FA3 Note 2 1 per 1.33 ft2 SBS-SA-H (Optional) BP-AA or SBS-AA SBS-AA -52.5 W-26 Min. 19/32-inch plywood at max. 24-inch spans (Optional) One or more layers, any combination, loose laid Min. 1.5-inch ACFoam II, FlintBoard ISO, H-Shield, FlintBoard ISOH Note 2 1 per 1.45 ft2 SBS-SA-H (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -60.0 Exterior Research and Design, LLC. d/b/a Trinity|ERD Evaluation Report 3520.03.04-R20 for FL2533-R19 Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 20: 09/14/2017 Prepared by: Robert Nieminen, PE-59166 CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 651-5847 Appendix 1, Page 9 of 57 TABLE 1C: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE C: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer Top Insulation Layer Roof Cover (Note 14) MDP (psf) Type Fasteners Attach Base Ply Cap W-27 Min. 15/32-inch plywood at max. 24-inch spans (Optional) Min. 1.5-inch, One or more layers, any combination, loose laid Min. 1.5-inch ACFoam II, FlintBoard ISO, H-Shield, FlintBoard ISOH Flintfast 3 in. Insulation Plates with FlintFast #12 or #14 1 per 1.33 ft2 SBS-SA-H (Optional) SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -75.0 W-28 Min. 19/32-inch exterior grade plywood at max. 24-inch spans (Optional) One or more layers, any combination, loose laid Min. 1.5-inch ACFoam II, FlintBoard ISO, ENRGY 3 or Multi-Max FA3 Note 2 1 per 1.33 ft2 SBS-SA-H (Optional) SBS-TA or APP-TA SBS-TA or APP-TA -82.5 CONVENTIONAL SYSTEMS: W-29 Min. 23/32-inch exterior grade plywood at max. 24-inch spans (Optional) One or more layers, any combination, loose laid Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation, min. 0.75-inch FescoBoard (homogeneous) Note 2 1 per 2 ft2 BP-AA or SBS-AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -45.0* W-30 Min. 15/32-inch plywood at max. 24-inch spans (Optional) One or more layers, any combination, loose laid Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board, Dens Deck or Dens Deck Prime FlintFast #12 or #14 HD ǁith FlintFast ϯ͟ Insulation Plates 1 per 2 ft2 BP-AA, SBS-AA, SBS-TA or APP-TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -45.0* W-31 Min. 15/32-inch plywood at max. 24-inch spans (Optional for Recover) Min. 1.5-inch, One or more layers, any combination, loose laid Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board FlintFast #12 or #14 HD ǁith FlintFast ϯ͟ Insulation Plates 1 per 1.45 ft2 APP-TA (Optional) APP-TA APP-TA -60.0 W-32 Min. 19/32-inch exterior grade plywood at max. 24-inch spans (Optional for Concrete or Recover) Min. 2-inch ACFoam II, FlintBoard, H-Shield or ENRGY 3, loose laid. Min. 0.5-inch SECUROCK Gypsum-Fiber Roof Board FlintFast #12 or #14 HD ǁith FlintFast ϯ͟ Insulation Plates 1 per 1.78 ft2 BP-AA, SBS-AA, SBS-TA or APP-TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -60.0 W-33 Min. 15/32-inch plywood at max. 24-inch spans (Optional for Recover) Min. 1.5-inch, One or more layers, any combination, loose laid Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board FlintFast #12 or #14 HD ǁith FlintFast ϯ͟ Insulation Plates 1 per 1.33 ft2 APP-TA (Optional) APP-TA APP-TA -67.5 Exterior Research and Design, LLC. d/b/a Trinity|ERD Evaluation Report 3520.03.04-R20 for FL2533-R19 Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 20: 09/14/2017 Prepared by: Robert Nieminen, PE-59166 CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 651-5847 Appendix 1, Page 10 of 57 TABLE 1D: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE D: INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Insulation Layer(s) Base or Anchor Sheet Roof Cover (Note 14) MDP (psf) Type Attach Base Fasteners Attach Ply Cap SELF-ADHERING SYSTEMS: W-34 Min. 19/32-inch plywood at max 24-inch spans Min. 1.5-inch, One or more layers, any combination Prelim. Attach Flintlastic SA NailBase Note 2 8-inch o.c. at min. 3-inch lap and 8-inch o.c. in two (2), equally spaced, staggered center rows; Stress plates shall be primed with FlintPrime (ASTM D41) primer or FlintPrime SA (Optional) SBS-SA SBS-SA -82.5* W-35 Min. 15/32-inch plywood at max 24-inch spans Min. 1.5-inch, One or more layers, any combination Prelim. Attach Flintlastic SA NailBase Flintfast 3 in. Insulation Plates with FlintFast #12 or #14; Trufast ϯ͟ Metal InsƵlation Plates with DP or HD; OMG 3 in. Round Metal Plates with OMG #14 HD 6-inch o.c. at min. 2-inch lap and 6-inch o.c. in three (3), equally spaced, staggered center rows; Stress plates shall be primed with FlintPrime (ASTM D41) primer or FlintPrime SA. (Optional) SBS-SA SBS-SA -97.5* W-36 Min. 15/32-inch plywood at max 24-inch spans Min. 1.5-inch, One or more layers, any combination Prelim. Attach Flintlastic SA NailBase Flintfast 3 in. Insulation Plates with FlintFast #12 or #14; Trufast ϯ͟ Metal InsƵlation Plates with DP or HD; OMG 3 in. Round Metal Plates with OMG #14 HD 6-inch o.c. at min. 2-inch lap and 6-inch o.c. in four (4), equally spaced, staggered center rows; Stress plates shall be primed with FlintPrime (ASTM D41) primer or FlintPrime SA. (Optional) SBS-SA SBS-SA -127.5* HYBRID SYSTEMS: W-37 Min. 15/32-inch plywood at max 24-inch spans Min. 1.5-inch, One or more layers, any combination Prelim. Attach Glasbase; Flexiglas; Flintlastic Base 20; Poly SMS Base; Ultra Poly SMS Base Flintfast 3 in. Insulation Plates with FlintFast #12 or #14; Trufast ϯ͟ Metal InsƵlation Plates with DP or HD; OMG 3 in. Round Metal Plates with OMG #14 HD 6-inch o.c. at 4-inch lap and 6-inch o.c. in three (3), equally spaced, staggered center rows; Stress plates shall be primed with FlintPrime (ASTM D41) primer or FlintPrime SA. SBS-SA-H SBS-AA, SBS-TA or APP-TA -97.5 W-38 Min. 19/32-inch plywood at max 24-inch spans Min. 1.5-inch, One or more layers, any combination Prelim. Attach Glasbase; Flexiglas; Flintlastic Base 20; Poly SMS Base; Ultra Poly SMS Base Note 2 7-inch o.c. at 3-inch lap and 7-inch o.c. in three (3), equally spaced, staggered center rows SBS-SA-H SBS-AA, SBS-TA or APP-TA -105.0 W-39 Min. 15/32-inch plywood at max 24-inch spans Min. 1.5-inch, One or more layers, any combination Prelim. Attach Glasbase; Flexiglas; Flintlastic Base 20; Poly SMS Base; Ultra Poly SMS Base Flintfast 3 in. Insulation Plates with FlintFast #12 or #14; Trufast ϯ͟ Metal InsƵlation Plates with DP or HD; OMG 3 in. Round Metal Plates with OMG #14 HD 6-inch o.c. at 4-inch lap and 6-inch o.c. in four (4), equally spaced, staggered center rows; Stress plates shall be primed with FlintPrime (ASTM D41) primer or FlintPrime SA. SBS-SA-H SBS-AA, SBS-TA or APP-TA -127.5 CONVENTIONAL SYSTEMS: Exterior Research and Design, LLC. d/b/a Trinity|ERD Evaluation Report 3520.03.04-R20 for FL2533-R19 Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 20: 09/14/2017 Prepared by: Robert Nieminen, PE-59166 CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 651-5847 Appendix 1, Page 11 of 57 TABLE 1D: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE D: INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Insulation Layer(s) Base or Anchor Sheet Roof Cover (Note 14) MDP (psf) Type Attach Base Fasteners Attach Ply Cap W-40 Min. 23/32-inch exterior grade plywood at max. 24-inch spans Min. 1.5-inch, One or more layers, any combination Prelim. Attach Glasbase; All Weather/Empire Base; Flexiglas Base; Flintlastic Base 20; Yosemite Note 2 12-inch o.c. at 4-inch lap and 36-inch o.c. in two (2), equally spaced, staggered center rows BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -30.0* W-41 Min. 23/32-inch exterior grade plywood at max. 24-inch spans Min. 1.5-inch, One or more layers, any combination Prelim. Attach Glasbase; All Weather/Empire Base; Flexiglas Base; Flintlastic Base 20; Yosemite Note 2 12-inch o.c. at 4-inch lap and 24-inch o.c. in two (2), equally spaced, staggered center rows BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -45.0* W-42 Min. 23/32-inch exterior grade plywood at max. 24-inch spans Min. 1.5-inch, One or more layers, any combination Prelim. Attach Poly SMS Base; Ultra Poly SMS Base Note 2 12-inch o.c. at 4-inch lap and 36-inch o.c. in two (2), equally spaced, staggered center rows BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -45.0* W-43 Min. 15/32-inch plywood at max 24-inch spans Min. 1.5-inch, One or more layers, any combination Prelim. Attach Glasbase; Flexiglas; Flintlastic Base 20; All Weather / Empire Base; Poly SMS Base; Ultra Poly SMS Base; Yosemite Flintfast 3 in. Insulation Plates with FlintFast #12 or #14; Trufast ϯ͟ Metal InsƵlation Plates with DP or HD; OMG 3 in. Round Metal Plates with OMG #14 HD 6-inch o.c. at 4-inch lap and 6-inch o.c. in three (3), equally spaced, staggered center rows. (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -97.5 W-44 Min. 15/32-inch plywood at max 24-inch spans Min. 1.5-inch, One or more layers, any combination Prelim. Attach Flintlastic APP Base T OMG 3 in. Round Metal Plates with OMG #14 HD 6-inch o.c. at 4-inch lap and 6-inch o.c. in three (3), equally spaced, staggered center rows. APP-TA APP-TA -97.5 W-45 Min. 15/32-inch plywood at max 24-inch spans One or more layers, any thickness or combination Prelim. Attach Glasbase; Flexiglas; Flintlastic Base 20; All Weather / Empire Base; Poly SMS Base; Ultra Poly SMS Base; Yosemite Flintfast 3 in. Insulation Plates with FlintFast #14; Trufast 3" Metal Insulation Plates with Trufast HD 8-inch o.c. at 4-inch lap and 8-inch o.c. at three (3) equally spaced, staggered center rows (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP_TA -97.5 W-46 Min. 19/32-inch plywood at max 24-inch spans Min. 1.5-inch, One or more layers, any combination Prelim. Attach Glasbase; Flexiglas; Flintlastic Base 20; Poly SMS Base; Ultra Poly SMS Base; Yosemite Note 2 7-inch o.c. at 3-inch lap and 7-inch o.c. in three (3), equally spaced, staggered center rows BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -105.0 W-47 Min. 19/32-inch plywood at max 24-inch spans Min. 1.5-inch, One or more layers, any combination Prelim. Attach Flintlastic APP Base T OMG 3 in. Round Metal Plates with OMG #14 HD or Dekfast Hex Plate with Dekfast #14 7-inch o.c. at 3-inch lap and 7-inch o.c. in three (3), equally spaced, staggered center rows APP-TA APP-TA -105.0 W-48 Min. 15/32-inch plywood at max 24-inch spans Min. 1.5-inch, One or more layers, any combination Prelim. Attach Glasbase; Flexiglas; Flintlastic Base 20; Poly SMS Base; Ultra Poly SMS Base; Yosemite Flintfast 3 in. Insulation Plates with FlintFast #12 or #14; Trufast ϯ͟ Metal InsƵlation Plates with DP or HD; OMG 3 in. Round Metal Plates with OMG #14 HD 6-inch o.c. at 4-inch lap and 6-inch o.c. in four (4), equally spaced, staggered center rows. (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -127.5 Exterior Research and Design, LLC. d/b/a Trinity|ERD Evaluation Report 3520.03.04-R20 for FL2533-R19 Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 20: 09/14/2017 Prepared by: Robert Nieminen, PE-59166 CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 651-5847 Appendix 1, Page 12 of 57 TABLE 1D: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE D: INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Insulation Layer(s) Base or Anchor Sheet Roof Cover (Note 14) MDP (psf) Type Attach Base Fasteners Attach Ply Cap W-49 Min. 15/32-inch plywood at max 24-inch spans Min. 1.5-inch, One or more layers, any combination Prelim. Attach Flintlastic APP Base T OMG 3 in. Round Metal Plates with OMG #14 HD 6-inch o.c. at 4-inch lap and 6-inch o.c. in four (4), equally spaced, staggered center rows. APP-TA APP-TA -127.5 COLD-APPLIED SYSTEMS: W-50 Min. 15/32-inch plywood at max 24-inch spans Min. 1-inch, One or more layers, any combination Loose-laid Glasbase; Flexiglas Base; Flintlastic Base 20; All Weather / Empire Base; Yosemite Venting Base; Flintlastic Poly SMS Base; Flintlastic Ultra Poly SMS Base Flintfast 3 in. Insulation Plates with FlintFast #12 or #14; Trufast ϯ͟ Metal Insulation Plates with DP or HD 8-inch o.c. at 4-inch lap and 8-inch o.c. in three (3), equally spaced, staggered center rows (Optional) SBS-CA1 SBS-CA1 -52.5 Exterior Research and Design, LLC. d/b/a Trinity|ERD Evaluation Report 3520.03.04-R20 for FL2533-R19 Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 20: 09/14/2017 Prepared by: Robert Nieminen, PE-59166 CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 651-5847 Appendix 1, Page 13 of 57 TABLE 1E-1: WOOD DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE E: NON-INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Base Sheet Roof Cover (Note 14) MDP (psf) Base Fasteners Attach Ply Cap SELF-ADHERING SYSTEMS: W-51 Min. 15/32-inch plywood at max 24-inch spans Flintlastic SA NailBase Simplex MAXX Cap 9-inch o.c. at min. 3-inch lap and 12-inch o.c. in two (2), equally spaced, staggered center rows; Stress plates shall be primed with FlintPrime (ASTM D41) primer. (Optional) SBS-SA SBS-SA -45.0* W-52 Min. 15/32-inch plywood at max 24-inch spans Flintlastic SA NailBase Min. 1-inch long, 12 ga. Simplex Metal Cap Nails 6-inch o.c. at min. 2-inch lap and 6-inch o.c. in four (4), equally spaced, staggered center rows (Optional) SBS-SA SBS-SA -52.5 W-53 Min. 19/32-inch plywood at max. 24-inch spans Flintlastic SA NailBase 32 ga., 1-5/8-inch dia. tin caps with 11 ga. annular ring shank nails 8-inch o.c. at min. 2-inch lap and 8-inch o.c. in three (3), equally spaced, staggered center rows (Optional) SBS-SA SBS-SA -52.5 W-54 Min. 19/32-inch plywood at max. 24-inch spans Flintlastic SA NailBase 32 ga., 1-5/8-inch dia. tin caps with 11 ga. annular ring shank nails 8-inch o.c. at min. 2-inch lap and 8-inch o.c. in three (3), equally spaced, staggered center rows (Optional) SBS-SA SBS-SA -60.0 W-55 Min. 15/32-inch plywood at max 24-inch spans Flintlastic SA NailBase Simplex MAXX Cap 8-inch o.c. at min. 3-inch lap and 8-inch o.c. in three (3), equally spaced, staggered center rows; Stress plates shall be primed with FlintPrime (ASTM D41) primer. (Optional) SBS-SA SBS-SA -67.5 W-56 Min. 19/32-inch plywood at max 24-inch spans Flintlastic SA NailBase 32 ga., 1-5/8-inch dia. tin caps with 11 ga. annular ring shank nails 6-inch o.c. at min. 2-inch lap and 6-inch o.c. in four (4), equally spaced, staggered center rows (Optional) SBS-SA SBS-SA -75.0 W-57 Min. 15/32-inch plywood at max 24-inch spans Flintlastic SA NailBase Cap nails: 1-inch diameter, 0.032-inch thick metal cap with 0.120" shank diameter, annular ring shank nails 7-inch o.c. at min. 4-inch laps and 7-inch o.c. in five (5), equally spaced, staggered center rows (Optional) SBS-SA SBS-SA -75.0 W-58 Min. 19/32-inch plywood at max 24-inch spans Flintlastic SA NailBase 32 ga., 1-5/8-inch dia. tin caps with 11 ga. annular ring shank nails 4-inch o.c. at min. 2-inch lap and 4-inch o.c. in four (4), equally spaced, staggered center rows (Optional) SBS-SA SBS-SA -105.0 HYBRID SYSTEMS: W-59 Min. 19/32-inch exterior grade plywood at max. 24-inch spans Glasbase; Flexiglas; Flintlastic Base 20; All Weather / Empire Base; Poly SMS Base; Ultra Poly SMS Base 32 ga., 1-5/8-inch dia. tin caps with 11 ga. annular ring shank nails 9-inch o.c. at 4-inch lap and 12-inch o.c. in two (2), equally spaced, staggered center rows SBS-SA-H SBS-AA, SBS-TA or APP-TA -45.0* W-60 Min. 15/32-inch plywood at max 24-inch spans Glasbase; Flexiglas; Flintlastic Base 20; All Weather / Empire Base; Poly SMS Base; Ultra Poly SMS Base Min. 1-inch long, 12 ga. Simplex Metal Cap Nails 6-inch o.c. at 3-inch lap and 6-inch o.c. in four (4), equally spaced, staggered center rows SBS-SA-H SBS-AA, SBS-TA or APP-TA -52.5 Exterior Research and Design, LLC. d/b/a Trinity|ERD Evaluation Report 3520.03.04-R20 for FL2533-R19 Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 20: 09/14/2017 Prepared by: Robert Nieminen, PE-59166 CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 651-5847 Appendix 1, Page 14 of 57 TABLE 1E-1: WOOD DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE E: NON-INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Base Sheet Roof Cover (Note 14) MDP (psf) Base Fasteners Attach Ply Cap W-61 Min. 19/32-inch plywood at max 24-inch spans Glasbase; Flexiglas; Flintlastic Base 20; Poly SMS Base; Ultra Poly SMS Base 32 ga., 1-5/8-inch dia. tin caps with 11 ga. annular ring shank nails 8-inch o.c. at 4-inch lap and 8-inch o.c. in three (3), equally spaced, staggered center rows SBS-SA-H SBS-AA, SBS-TA or APP-TA -52.5 W-62 Min. 19/32-inch plywood at max 24-inch spans Glasbase; Flexiglas; Flintlastic Base 20; Poly SMS Base; Ultra Poly SMS Base 32 ga., 1-5/8-inch dia. tin caps with 11 ga. annular ring shank nails 8-inch o.c. at 4-inch lap and 8-inch o.c. in three (3), equally spaced, staggered center rows SBS-SA-H SBS-AA, SBS-TA or APP-TA -60.0 W-63 Min. 19/32-inch plywood at max 24-inch spans Glasbase; Flexiglas; Flintlastic Base 20; Poly SMS Base; Ultra Poly SMS Base 32 ga., 1-5/8-inch dia. tin caps with 11 ga. annular ring shank nails 6-inch o.c. at 4-inch lap and 6-inch o.c. in four (4), equally spaced, staggered center rows SBS-SA-H SBS-AA, SBS-TA or APP-TA -82.5 W-64 Min. 19/32-inch plywood at max 24-inch spans Glasbase; Flexiglas; Flintlastic Base 20; Poly SMS Base; Ultra Poly SMS Base 32 ga., 1-5/8-inch dia. tin caps with 11 ga. annular ring shank nails 4-inch o.c. at 3-inch lap and 4-inch o.c. in four (4), equally spaced, staggered center rows SBS-SA-H SBS-AA, SBS-TA or APP-TA -105.0 CONVENTIONAL SYSTEMS: W-65 Min. 19/32-inch exterior grade plywood at max. 24-inch spans Glasbase; Flexiglas; Flintlastic Base 20; All Weather / Empire Base; Poly SMS Base; Ultra Poly SMS Base; Yosemite 32 ga., 1-5/8-inch dia. tin caps with 11 ga. annular ring shank nails 9-inch o.c. at 4-inch lap and 12-inch o.c. in two (2), equally spaced, staggered center rows BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -45.0* W-66 Min. 15/32-inch exterior grade plywood at max. 24-inch spans Glasbase; Flexiglas; Flintlastic Base 20; All Weather / Empire Base; Poly SMS Base; Yosemite Simplex MAXX Cap 9-inch o.c. at 2-inch lap and 18-inch o.c. in two (2), equally spaced, staggered center rows (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -45.0* W-67 Min. 15/32-inch exterior grade plywood at max. 24-inch spans Flintlastic APP Base T Simplex MAXX Cap 9-inch o.c. at 2-inch lap and 18-inch o.c. in two (2), equally spaced, staggered center rows (Optional) APP-TA APP-TA -45.0* W-68 Min. 15/32-inch plywood at max 24-inch spans Glasbase; Flexiglas; Flintlastic Base 20; All Weather / Empire Base; Poly SMS Base; Ultra Poly SMS Base; Yosemite Min. 1-inch long, 12 ga. Simplex Metal Cap Nails 6-inch o.c. at 3-inch lap and 6-inch o.c. in four (4), equally spaced, staggered center rows (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -52.5 W-69 Min. 19/32-inch plywood at max 24-inch spans Glasbase; Flexiglas; Flintlastic Base 20; Poly SMS Base; Ultra Poly SMS Base; Yosemite 32 ga., 1-5/8-inch dia. tin caps with 11 ga. annular ring shank nails 8-inch o.c. at 4-inch lap and 8-inch o.c. in three (3), equally spaced, staggered center rows BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -52.5 W-70 Min. 15/32-inch exterior grade plywood at max. 24-inch spans Glasbase; Flexiglas; Flintlastic Base 20; All Weather / Empire Base; Poly SMS Base; Yosemite Simplex MAXX Cap 9-inch o.c. at 2-inch lap and 12-inch o.c. in two (2), equally spaced, staggered center rows (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -52.5 W-71 Min. 15/32-inch exterior grade plywood at max. 24-inch spans Flintlastic APP Base T Simplex MAXX Cap 9-inch o.c. at 2-inch lap and 12-inch o.c. in two (2), equally spaced, staggered center rows (Optional) APP-TA APP-TA -52.5 W-72 Min. 19/32-inch plywood at max 24-inch spans Glasbase; Flexiglas; Flintlastic Base 20; Poly SMS Base; Ultra Poly SMS Base; Yosemite 32 ga., 1-5/8-inch dia. tin caps with 11 ga. annular ring shank nails 8-inch o.c. at 4-inch lap and 8-inch o.c. in three (3), equally spaced, staggered center rows BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -60.0 Exterior Research and Design, LLC. d/b/a Trinity|ERD Evaluation Report 3520.03.04-R20 for FL2533-R19 Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 20: 09/14/2017 Prepared by: Robert Nieminen, PE-59166 CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 651-5847 Appendix 1, Page 15 of 57 TABLE 1E-1: WOOD DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE E: NON-INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Base Sheet Roof Cover (Note 14) MDP (psf) Base Fasteners Attach Ply Cap W-73 Min. 15/32-inch plywood at max 24-inch spans Glasbase; Flexiglas; Flintlastic Base 20; All Weather / Empire Base; Poly SMS Base; Ultra Poly SMS Base; Yosemite Cap nails: 1-inch diameter, 0.032-inch thick metal cap with 0.120-inch shank diameter, annular ring shank nails. 6-inch o.c. at 4-inch lap and 6-inch o.c. at five (5) equally spaced, staggered center rows (Optional) BP-AA, SBS-AA or SBS-TA SBS-AA or SBS-TA -67.5 W-74 Min. 19/32-inch plywood at max 24-inch spans Glasbase; Flexiglas; Flintlastic Base 20; Poly SMS Base; Ultra Poly SMS Base; Yosemite 32 ga., 1-5/8-inch dia. tin caps with 11 ga. annular ring shank nails 6-inch o.c. at 4-inch lap and 6-inch o.c. in four (4), equally spaced, staggered center rows BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -82.5 W-75 Min. 15/32-inch exterior grade plywood at max. 24-inch spans Glasbase; Flexiglas; Flintlastic Base 20; All Weather / Empire Base; Poly SMS Base; Yosemite Simplex MAXX Cap 6-inch o.c. at 2-inch lap and 6-inch o.c. in two (2), equally spaced, staggered center rows (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -90.0 W-76 Min. 15/32-inch exterior grade plywood at max. 24-inch spans Flintlastic APP Base T Simplex MAXX Cap 6-inch o.c. at 2-inch lap and 6-inch o.c. in two (2), equally spaced, staggered center rows (Optional) APP-TA APP-TA -90.0 W-77 Min. 19/32-inch plywood at max 24-inch spans Glasbase; Flexiglas; Flintlastic Base 20; Poly SMS Base; Ultra Poly SMS Base; Yosemite 32 ga., 1-5/8-inch dia. tin caps with 11 ga. annular ring shank nails 4-inch o.c. at 3-inch lap and 4-inch o.c. in four (4), equally spaced, staggered center rows BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -105.0 W-78 Min. 15/32-inch exterior grade plywood at max. 24-inch spans Glasbase; Flexiglas; Flintlastic Base 20; All Weather / Empire Base; Poly SMS Base; Yosemite Simplex MAXX Cap 6-inch o.c. at 2-inch lap and 6-inch o.c. in three (3), equally spaced, staggered center rows (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -105.0 W-79 Min. 15/32-inch exterior grade plywood at max. 24-inch spans Flintlastic APP Base T Simplex MAXX Cap 6-inch o.c. at 2-inch lap and 6-inch o.c. in three (3), equally spaced, staggered center rows (Optional) APP-TA APP-TA -105.0 Exterior Research and Design, LLC. d/b/a Trinity|ERD Evaluation Report 3520.03.04-R20 for FL2533-R19 Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 20: 09/14/2017 Prepared by: Robert Nieminen, PE-59166 CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 651-5847 Appendix 1, Page 16 of 57 TABLE 1E-2: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE E: NON-INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Base Sheet Roof Cover (Note 14) MDP (psf) Base Fasteners Attach Ply Cap SELF-ADHERING SYSTEMS: W-80 Min. 19/32-inch plywood at max 24-inch spans Flintlastic SA NailBase Note 2 8-inch o.c. at min. 3-inch lap and 8-inch o.c. in two (2), equally spaced, staggered center rows. Stress plates shall be primed with FlintPrime (ASTM D41) primer or FlintPrime SA (Optional) SBS-SA SBS-SA -82.5* W-81 Min. 15/32-inch plywood at max 24-inch spans Flintlastic SA NailBase Flintfast 3 in. Insulation Plates with FlintFast #12 or #14; Trufast ϯ͟ Metal Insulation Plates with DP or HD; OMG 3 in. Round Metal Plates with OMG #14 HD 6-inch o.c. at min. 2-inch lap and 6-inch o.c. in three (3), equally spaced, staggered center rows. Stress plates shall be primed with FlintPrime (ASTM D41) primer or FlintPrime SA. (Optional) SBS-SA SBS-SA -97.5* W-82 Min. 15/32-inch plywood at max 24-inch spans Flintlastic SA NailBase Flintfast 3 in. Insulation Plates with FlintFast #12 or #14; Trufast ϯ͟ Metal Insulation Plates with DP or HD; OMG 3 in. Round Metal Plates with OMG #14 HD 6-inch o.c. at min. 2-inch lap and 6-inch o.c. in four (4), equally spaced, staggered center rows. Stress plates shall be primed with FlintPrime (ASTM D41) primer or FlintPrime SA. (Optional) SBS-SA SBS-SA -127.5* HYBRID SYSTEMS: W-83 Min. 15/32-inch plywood at max 24-inch spans Glasbase; Flexiglas; Flintlastic Base 20; Poly SMS Base; Ultra Poly SMS Base Flintfast 3 in. Insulation Plates with FlintFast #12 or #14; Trufast ϯ͟ Metal Insulation Plates with DP or HD; OMG 3 in. Round Metal Plates with OMG #14 HD 6-inch o.c. at 4-inch lap and 6-inch o.c. in three (3), equally spaced, staggered center rows. Stress plates shall be primed with FlintPrime (ASTM D41) primer or FlintPrime SA. SBS-SA-H SBS-AA, SBS-TA or APP-TA -97.5 W-84 Min. 19/32-inch plywood at max 24-inch spans Glasbase; Flexiglas; Flintlastic Base 20; Poly SMS Base; Ultra Poly SMS Base Note 2 7-inch o.c. at 3-inch lap and 7-inch o.c. in three (3), equally spaced, staggered center rows SBS-SA-H SBS-AA, SBS-TA or APP-TA -105.0 W-85 Min. 15/32-inch plywood at max 24-inch spans Glasbase; Flexiglas; Flintlastic Base 20; Poly SMS Base; Ultra Poly SMS Base Flintfast 3 in. Insulation Plates with FlintFast #12 or #14; Trufast ϯ͟ Metal Insulation Plates with DP or HD; OMG 3 in. Round Metal Plates with OMG #14 HD 6-inch o.c. at 4-inch lap and 6-inch o.c. in four (4), equally spaced, staggered center rows. Stress plates shall be primed with FlintPrime (ASTM D41) primer or FlintPrime SA. SBS-SA-H SBS-AA, SBS-TA or APP-TA -127.5 CONVENTIONAL SYSTEMS: W-86 Min. 23/32-inch exterior grade plywood at max. 24-inch spans Glasbase; All Weather/Empire Base; Flexiglas Base; Flintlastic Base 20; Yosemite Note 2 12-inch o.c. at 4-inch lap and 36-inch o.c. in two (2), equally spaced, staggered center rows BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -30.0* W-87 Min. 23/32-inch exterior grade plywood at max. 24-inch spans Glasbase; All Weather/Empire Base; Flexiglas Base; Flintlastic Base 20; Yosemite Note 2 12-inch o.c. at 4-inch lap and 24-inch o.c. in two (2), equally spaced, staggered center rows BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -45.0* W-88 Min. 23/32-inch exterior grade plywood at max. 24-inch spans Poly SMS Base; Ultra Poly SMS Base Note 2 12-inch o.c. at 4-inch lap and 36-inch o.c. in two (2), equally spaced, staggered center rows BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -45.0* Exterior Research and Design, LLC. d/b/a Trinity|ERD Evaluation Report 3520.03.04-R20 for FL2533-R19 Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 20: 09/14/2017 Prepared by: Robert Nieminen, PE-59166 CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 651-5847 Appendix 1, Page 17 of 57 TABLE 1E-2: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE E: NON-INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Base Sheet Roof Cover (Note 14) MDP (psf) Base Fasteners Attach Ply Cap W-89 Min. 15/32-inch plywood at max 24-inch spans Glasbase; Flexiglas; Flintlastic Base 20; Poly SMS Base; Ultra Poly SMS Base; Yosemite Flintfast 3 in. Insulation Plates with FlintFast #12 or #14; Trufast ϯ͟ Metal Insulation Plates with DP or HD; OMG 3 in. Round Metal Plates with OMG #14 HD 6-inch o.c. at 4-inch lap and 6-inch o.c. in three (3), equally spaced, staggered center rows (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -97.5 W-90 Min. 15/32-inch plywood at max 24-inch spans Flintlastic APP Base T OMG 3 in. Round Metal Plates with OMG #14 HD 6-inch o.c. at 4-inch lap and 6-inch o.c. in three (3), equally spaced, staggered center rows. APP-TA APP-TA -97.5 W-91 Min. 15/32-inch plywood at max 24-inch spans Glasbase; Flexiglas; Flintlastic Base 20; All Weather / Empire Base; Poly SMS Base; Ultra Poly SMS Base; Yosemite Flintfast 3 in. Insulation Plates with FlintFast #14; Trufast 3" Metal Insulation Plates with Trufast HD 8-inch o.c. at 4-inch lap and 8-inch o.c. at three (3) equally spaced, staggered center rows (Optional) BP-AA, SBS-AA or SBS-TA SBS-AA or SBS-TA -97.5 W-92 Min. 19/32-inch plywood at max 24-inch spans Glasbase; Flexiglas; Flintlastic Base 20; Poly SMS Base; Ultra Poly SMS Base; Yosemite Note 2 7-inch o.c. at 3-inch lap and 7-inch o.c. in three (3), equally spaced, staggered center rows BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -105.0 W-93 Min. 19/32-inch plywood at max 24-inch spans Flintlastic APP Base T OMG 3 in. Round Metal Plates with OMG #14 HD or Dekfast Hex Plate with Dekfast #14 7-inch o.c. at 3-inch lap and 7-inch o.c. in three (3), equally spaced, staggered center rows APP-TA APP-TA -105.0 W-94 Min. 15/32-inch plywood at max 24-inch spans Glasbase; Flexiglas; Flintlastic Base 20; Poly SMS Base; Ultra Poly SMS Base; Yosemite Flintfast 3 in. Insulation Plates with FlintFast #12 or #14; Trufast ϯ͟ Metal Insulation Plates with DP or HD; OMG 3 in. Round Metal Plates with OMG #14 HD 6-inch o.c. at 4-inch lap and 6-inch o.c. in four (4), equally spaced, staggered center rows (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -127.5 W-95 Min. 15/32-inch plywood at max 24-inch spans Flintlastic APP Base T OMG 3 in. Round Metal Plates with OMG #14 HD 6-inch o.c. at 4-inch lap and 6-inch o.c. in four (4), equally spaced, staggered center rows. APP-TA APP-TA -127.5 COLD-APPLIED SYSTEMS: W-96 Min. 15/32-inch plywood at max 24-inch spans Glasbase; Flexiglas Base; Flintlastic Base 20; All Weather / Empire Base; Yosemite Venting Base; Flintlastic Poly SMS Base; Flintlastic Ultra Poly SMS Base Flintfast 3 in. Insulation Plates with FlintFast #12 or #14; Trufast ϯ͟ Metal Insulation Plates with DP or HD 8-inch o.c. at 4-inch lap and 8-inch o.c. in three (3), equally spaced, staggered center rows (Optional) SBS-CA1 SBS-CA1 -52.5 TABLE 1F: WOOD DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE F: NON-INSULATED, BONDED ROOF COVER System No. Deck (Note 1) Primer Roof Cover (Note 14) MDP (psf) Base Ply Cap W-97 Min. 15/32-inch plywood at max 24-inch spans FlintPrime or FlintPrime SA SBS-SA-H (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -112.5 W-98 Min. 15/32-inch plywood at max 24-inch spans FlintPrime or FlintPrime SA SBS-SA (Optional) SBS-SA SBS-SA -127.5 Exterior Research and Design, LLC. d/b/a Trinity|ERD Evaluation Report 3520.03.04-R20 for FL2533-R19 Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 20: 09/14/2017 Prepared by: Robert Nieminen, PE-59166 CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 651-5847 Appendix 1, Page 18 of 57 TABLE 2A: STEEL OR STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE B: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer Top Insulation Layer Roof Cover (Note 14) MDP (psf) Type Fasteners Attach Type Attach Base Ply Cap SELF-ADHERING SYSTEMS: S-1 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 2-inch ACFoam II, FlintBoard, ENRGY 3 or H-Shield Note 2 1 per 4 ft2 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board HA, D-IS, M-OSFA, OB500 or CR-20 SBS-SA (Optional) SBS-SA SBS-SA -37.5* S-2 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 1.5-inch ACFoam II, FlintBoard, ENRGY 3 or H-Shield Note 2 1 per 2 ft2 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board HA, D-IS, M-OSFA, OB500 or CR-20 SBS-SA (Optional) SBS-SA SBS-SA -45.0* HYBRID SYSTEMS: S-3 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 1.5-inch ACFoam II, FlintBoard, ENRGY 3 or H-Shield Note 2 1 per 1.45 ft2 Additional layer(s) base insulation HA, D-IS, M-OSFA, OB500 or CR-20 Flintlastic Ultra Glass SA (Optional) SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -37.5 S-4 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 1.5-inch ACFoam II, FlintBoard, ENRGY 3 or H-Shield Note 2 1 per 1.45 ft2 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board HA, D-IS, M-OSFA, OB500 or CR-20 Flintlastic Ultra Glass SA (Optional) SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -52.5 S-5 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 1.5-inch ACFoam II, FlintBoard ISO, H-Shield or FlintBoard ISOH. FlintFast #12 or #14 with FlintFast ϯ͟ InsƵlation Plates 1 per 1.45 ft2 Min. 1.5-inch ACFoam II, FlintBoard ISO, H-Shield or FlintBoard ISOH. HA, D-IS, M-OSFA, M-PG1 or OB500 SBS-SA-H (Optional) APP-TA APP-TA -67.5 S-6 Min. 22 ga., type B, Grade 40 steel or min. 2,500 psi structrual concrete Min. 1.5-inch ACFoam II, FlintBoard ISO, H-Shield or FlintBoard ISOH FlintFast #12 (steel only) or #14 HD with FlintFast ϯ͟ InsƵlation Plates or Trufast #12 (steel only) or HD ǁith TrƵfast ϯ͟ Metal Insulation Plates 1 per 1.6 ft2 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board D-IS, M-OSFA, M-PG1 or OB500 SBS-SA-H (Optional) SBS-TA or APP-TA SBS-TA or APP-TA -75.0 S-7 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 1.5-inch ENRGY 3 FlintFast #12 (steel only) or #14 HD ǁith FlintFast ϯ͟ InsƵlation Plates or Trufast #12 (steel only) or HD ǁith TrƵfast ϯ͟ Metal Insulation Plates 1 per 1 ft2 Min. 0.5-inch SECUROCK Gypsum-Fiber Roof Board OB500, 4-inch o.c. SBS-SA-H (Optional) SBS-TA or APP-TA SBS-TA or APP-TA -90.0* CONVENTIONAL SYSTEMS: S-8 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 2-inch ACFoam II, FlintBoard, ENRGY 3 or H-Shield Note 2 1 per 4 ft2 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board HA, D-IS, M-OSFA, OB500 or CR-20 BP-AA, SBS-AA, SBS-TA or APP-TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -37.5* S-9 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 1.5-inch ACFoam II, FlintBoard, ENRGY 3 or H-Shield Note 2 1 per 2 ft2 Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation, min. 0.75-inch FescoBoard (homogeneous). HA BP-AA or SBS-AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -45.0* Exterior Research and Design, LLC. d/b/a Trinity|ERD Evaluation Report 3520.03.04-R20 for FL2533-R19 Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 20: 09/14/2017 Prepared by: Robert Nieminen, PE-59166 CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 651-5847 Appendix 1, Page 19 of 57 TABLE 2A: STEEL OR STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE B: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer Top Insulation Layer Roof Cover (Note 14) MDP (psf) Type Fasteners Attach Type Attach Base Ply Cap S-10 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 1.5-inch ACFoam II, FlintBoard, ENRGY 3 or H-Shield Note 2 1 per 2 ft2 Min. 0.25-inch Dens Deck or Dens Deck Prime HA BP-AA, SBS-AA, SBS-TA or APP-TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -45.0* S-11 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 1.5-inch ACFoam II, FlintBoard, ENRGY 3 or H-Shield Note 2 1 per 2 ft2 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board HA, D-IS, M-OSFA, OB500 or CR-20 BP-AA, SBS-AA, SBS-TA or APP-TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -45.0* S-12 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 2-inch ACFoam II, FlintBoard, ENRGY 3 or H-Shield Note 2 1 per 3.2 ft2 Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation, min. 0.75-inch FescoBoard (homogeneous). HA BP-AA or SBS-AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -45.0* S-13 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 2-inch ACFoam II, FlintBoard, ENRGY 3 or H-Shield Note 2 1 per 3.2 ft2 Min. 0.25-inch Dens Deck or Dens Deck Prime HA BP-AA, SBS-AA, SBS-TA or APP-TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -45.0* S-14 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 1.5-inch ACFoam II, FlintBoard, ENRGY 3 or Mult-Max FA3 Note 2 1 per 1.33 ft2 Min. 0.75-inch FescoBoard (homogeneous) HA BP-AA or SBS-AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -52.5 S-15 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 2-inch ACFoam II, FlintBoard, ENRGY 3 or H-Shield Note 2 1 per 1.6 ft2 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board HA, D-IS, M-OSFA, OB500 or CR-20 BP-AA, SBS-AA, SBS-TA or APP-TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -60.0 S-16 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 1.5-inch ACFoam II, FlintBoard, ENRGY 3 or Mult-Max FA3 Note 2 1 per 1.33 ft2 Min. 0.5-inch Structodek High Density Fiberboard HA BP-AA or SBS-AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -67.5 S-17 Min. 22 ga., type B, Grade 40 steel or min. 2,500 psi structrual concrete Min. 1.5-inch ACFoam II, FlintBoard ISO, H-Shield or FlintBoard ISOH FlintFast #12 (steel only) or #14 HD ǁith FlintFast ϯ͟ InsƵlation Plates or Trufast #12 (steel only) or HD ǁith TrƵfast ϯ͟ Metal Insulation Plates 1 per 1.6 ft2 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board D-IS, M-OSFA, M-PG1 or OB500 BP-AA, SBS-AA, SBS-TA or APP-TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -75.0 S-18 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 1.5-inch ENRGY 3 FlintFast #12 (steel only) or #14 HD ǁith FlintFast ϯ͟ InsƵlation Plates or Trufast #12 (steel only) or HD ǁith TrƵfast ϯ͟ Metal Insulation Plates 1 per 1 ft2 Min. 0.5-inch SECUROCK Gypsum-Fiber Roof Board OB500, 4-inch o.c. BP-AA, SBS-AA, SBS-TA or APP-TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -90.0* COLD-APPLIED SYSTEMS: Exterior Research and Design, LLC. d/b/a Trinity|ERD Evaluation Report 3520.03.04-R20 for FL2533-R19 Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 20: 09/14/2017 Prepared by: Robert Nieminen, PE-59166 CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 651-5847 Appendix 1, Page 20 of 57 TABLE 2A: STEEL OR STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE B: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer Top Insulation Layer Roof Cover (Note 14) MDP (psf) Type Fasteners Attach Type Attach Base Ply Cap S-19 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 2-inch ACFoam II, FlintBoard ISO, H-Shield or FlintBoard ISOH FlintFast #12 (steel only) or #14 HD ǁith FlintFast ϯ͟ InsƵlation Plates or Trufast #12 (steel only) or HD ǁith TrƵfast ϯ͟ Metal Insulation Plates 1 per 2 ft2 Min. 1.5-inch ACFoam III, FlintBoard Iso Cold, H-Shield CG or FlintBoard Iso ColdH OB500 or CR-20 SBS-CA1 None SBS-CA1 -45.0* S-20 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 2-inch ACFoam II, FlintBoard ISO, H-Shield or FlintBoard ISOH FlintFast #12 (steel only) or #14 HD ǁith FlintFast ϯ͟ InsƵlation Plates or Trufast #12 (steel only) or HD ǁith TrƵfast ϯ͟ Metal Insulation Plates 1 per 2 ft2 Optional min. 1.5-inch additional layer(s) base insulation, followed by min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board D-IS, M-OSFA, M-PG1, OB500 or CR-20 SBS-CA1 None SBS-CA1 -45.0* S-21 Min. 22 ga., type B, Grade 40 steel or min. 2,500 psi structrual concrete Min. 1.5-inch ACFoam II, FlintBoard ISO, H-Shield or FlintBoard ISOH FlintFast #12 (steel only) or #14 HD with FlintFast ϯ͟ InsƵlation Plates or Trufast #12 (steel only) or HD ǁith TrƵfast ϯ͟ Metal Insulation Plates 1 per 1.6 ft2 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board D-IS, M-OSFA, M-PG1 or OB500 SBS-CA1 None SBS-CA1 -75.0 S-22 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 1.5-inch ENRGY 3 FlintFast #12 (steel only) or #14 HD ǁith FlintFast ϯ͟ InsƵlation Plates or Trufast #12 (steel only) or HD ǁith TrƵfast ϯ͟ Metal Insulation Plates 1 per 1 ft2 Min. 0.5-inch SECUROCK Gypsum-Fiber Roof Board OB500, 4-inch o.c. SBS-CA1 None SBS-CA1 -90.0* Exterior Research and Design, LLC. d/b/a Trinity|ERD Evaluation Report 3520.03.04-R20 for FL2533-R19 Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 20: 09/14/2017 Prepared by: Robert Nieminen, PE-59166 CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 651-5847 Appendix 1, Page 21 of 57 TABLE 2B: STEEL OR STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE C: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer(s) Top Insulation Layer Roof Cover (Note 14) MDP (psf) Type Fasteners Attach Base Ply Cap SELF-ADHERING SYSTEMS: S-23 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Note 2 1 per 3.2 ft2 SBS-SA (Optional) SBS-SA SBS-SA -30.0* S-24 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board FlintFast #12 (steel only) or ηϭϰ HD ǁith FlintFast ϯ͟ Insulation Plates or Trufast #12 (steel only) or HD with Trufast ϯ͟ Metal InsƵlation Plates 1 per 2.7 ft2 SBS-SA (Optional) SBS-SA SBS-SA -37.5* S-25 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 3/8-inch SECUROCK Gypsum-Fiber Roof Board Note 2 1 per 2.7 ft2 SBS-SA (Optional) SBS-SA SBS-SA -45.0* S-26 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 0.25-inch Dens Deck Note 2 1 per 1.33 ft2 Apply FlintPrime or FlintPrime SA to board & plates, followed by SBS-SA (Optional) SBS-SA SBS-SA -45.0 S-27 Min. 22 ga., type B, Grade 40 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 1.5-inch FlintBoard ISO FlintFast #14 HD with FlintFast ϯ͟ InsƵlation Plates or TrƵfast HD with TrƵfast ϯ͟ Metal Insulation Plates 1 per 1.78 ft2 Apply FlintPrime to board & plates, followed by SBS-SA (Optional) SBS-SA SBS-SA -67.5 S-28 Min. 22 ga., type B, Grade 40 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 0.5-inch SECUROCK Gypsum-Fiber Roof Board FlintFast #14 HD with FlintFast ϯ͟ InsƵlation Plates or TrƵfast HD ǁith TrƵfast ϯ͟ Metal Insulation Plates 1 per 1.6 ft2 Apply FlintPrime to board & plates, followed by SBS-SA (Optional) SBS-SA SBS-SA -82.5 HYBRID SYSTEMS: S-29 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 0.25-inch Dens Deck; Dens Deck Prime Note 2 1 per 2 ft2 SBS-SA-H (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -30.0* S-30 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board FlintFast #12 (steel only) or ηϭϰ HD ǁith FlintFast ϯ͟ Insulation Plates or Trufast #12 (steel only) or HD with Trufast ϯ͟ Metal InsƵlation Plates 1 per 2.7 ft2 SBS-SA-H (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -37.5* S-31 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 3/8-inch SECUROCK Gypsum-Fiber Roof Board FlintFast #12 (steel only) or ηϭϰ HD ǁith FlintFast ϯ͟ Insulation Plates or Trufast #12 (steel only) or HD with Trufast ϯ͟ Metal InsƵlation Plates 1 per 2.7 ft2 SBS-SA-H (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -45.0* Exterior Research and Design, LLC. d/b/a Trinity|ERD Evaluation Report 3520.03.04-R20 for FL2533-R19 Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 20: 09/14/2017 Prepared by: Robert Nieminen, PE-59166 CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 651-5847 Appendix 1, Page 22 of 57 TABLE 2B: STEEL OR STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE C: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer(s) Top Insulation Layer Roof Cover (Note 14) MDP (psf) Type Fasteners Attach Base Ply Cap S-32 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 1.5-inch ACFoam II, FlintBoard ISO, ENRGY 3 or Multi-Max FA3 Note 2 1 per 1.33 ft2 SBS-SA-H (Optional) BP-AA or SBS-AA SBS-AA -52.5 S-33 Min. 22 ga., type B, Grade 40 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 1.5-inch FlintBoard ISO FlintFast #14 HD with FlintFast ϯ͟ InsƵlation Plates or TrƵfast HD ǁith TrƵfast ϯ͟ Metal Insulation Plates 1 per 1.78 ft2 SBS-SA-H (Optional) SBS-TA or APP-TA SBS-TA or APP-TA -67.5 S-34 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 1.5-inch ACFoam II, FlintBoard ISO, H-Shield or FlintBoard ISOH. FlintFast #12 (steel only) or ηϭϰ HD ǁith FlintFast ϯ͟ Insulation Plates 1 per 1.45 ft2 SBS-SA-H (Optional) SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -75.0 S-35 Min. 22 ga., type B, Grade 40 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 0.5-inch SECUROCK Gypsum-Fiber Roof Board FlintFast #14 HD with FlintFast ϯ͟ InsƵlation Plates or TrƵfast HD ǁith TrƵfast ϯ͟ Metal Insulation Plates 1 per 1.6 ft2 SBS-SA-H (Optional) SBS-TA or APP-TA SBS-TA or APP-TA -82.5 S-36 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 0.5-inch SECUROCK Gypsum-Fiber Roof Board FlintFast #12 (steel only) or ηϭϰ HD ǁith FlintFast ϯ͟ Insulation Plates or Trufast #12 (steel only) or HD with Trufast ϯ͟ Metal InsƵlation Plates 1 per 1.45 ft2 SBS-SA-H (Optional) SBS-TA or APP-TA SBS-TA or APP-TA -82.5 S-37 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 1.5-inch ACFoam II, FlintBoard ISO, ENRGY 3 or Multi-Max FA3 Note 2 1 per 1.33 ft2 SBS-SA-H (Optional) SBS-TA or APP-TA SBS-TA or APP-TA -82.5 S-38 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 0.5-inch SECUROCK Gypsum-Fiber Roof Board FlintFast #12 (steel only) or ηϭϰ HD ǁith FlintFast ϯ͟ Insulation Plates or Trufast #12 (steel only) or HD with Trufast ϯ͟ Metal InsƵlation Plates 1 per 1 ft2 SBS-SA-H (Optional) SBS-TA or APP-TA SBS-TA or APP-TA -135.0 CONVENTIONAL SYSTEMS: S-39 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 0.75-inch FescoBoard (homogeneous) Note 2 1 per 2.67 ft2 BP-AA, SBS-AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -30.0* S-40 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation Note 2 1 per 4 ft2 BP-AA, SBS-AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -37.5* Exterior Research and Design, LLC. d/b/a Trinity|ERD Evaluation Report 3520.03.04-R20 for FL2533-R19 Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 20: 09/14/2017 Prepared by: Robert Nieminen, PE-59166 CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 651-5847 Appendix 1, Page 23 of 57 TABLE 2B: STEEL OR STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE C: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer(s) Top Insulation Layer Roof Cover (Note 14) MDP (psf) Type Fasteners Attach Base Ply Cap S-41 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Note 2 1 per 4 ft2 BP-AA, SBS-AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -37.5* S-42 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 2-inch ACFoam II, FlintBoard or ENRGY 3 Note 2 1 per 1.6 ft2 BP-AA2 (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -37.5* S-43 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Note 2 1 per 4 ft2 BP-AA, SBS-AA, SBS-TA or APP-TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -45.0* S-44 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation, min. 0.75-inch FescoBoard (homogeneous) Note 2 1 per 2 ft2 BP-AA or SBS-AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -45.0* S-45 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 0.25-inch Dens Deck or Dens Deck Prime Note 2 1 per 2 ft2 BP-AA, SBS-AA, SBS-TA or APP-TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -45.0* S-46 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 1-inch FescoBoard (homogeneous) or min. 1.5-inch FescoBoard (laminated) Note 2 1 per 1.6 ft2 BP-AA2 (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -45.0* S-47 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 0.5-inch Structodek, Structodek HD, GP HD Roof Fiberboard or Temple HD1 or HD6 Note 2 1 per 2 ft2 BP-AA2 (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -45.0* S-48 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 1.5-inch ACFoam II, FlintBoard Note 2 1 per 1.45 ft2 BP-AA3, 24-inch grid (Optional) BP-AA or SBS-AA SBS-AA -52.5 S-49 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 1.5-inch ACFoam II, FlintBoard Note 2 1 per 1.45 ft2 BP-AA3, 24-inch grid BP-AA or SBS-AA SBS-TA -52.5 S-50 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete (Optional for Concrete or Recover) Min. 1.5-inch, One or more layers, any combination, loose laid Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board FlintFast #12 (steel only) or #14 HD with FlintFast ϯ͟ Insulation Plates 1 per 1.45 ft2 APP-TA (Optional) APP-TA APP-TA -60.0 Exterior Research and Design, LLC. d/b/a Trinity|ERD Evaluation Report 3520.03.04-R20 for FL2533-R19 Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 20: 09/14/2017 Prepared by: Robert Nieminen, PE-59166 CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 651-5847 Appendix 1, Page 24 of 57 TABLE 2B: STEEL OR STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE C: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer(s) Top Insulation Layer Roof Cover (Note 14) MDP (psf) Type Fasteners Attach Base Ply Cap S-51 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete (Optional for Concrete or Recover) Min. 2-inch ACFoam II, FlintBoard, H-Shield or ENRGY 3, loose laid. Min. 0.5-inch SECUROCK Gypsum-Fiber Roof Board Note 2 1 per 1.78 ft2 BP-AA, SBS-AA, SBS-TA or APP-TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -60.0 S-52 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 0.5-inch SECUROCK Gypsum-Fiber Roof Board FlintFast #12 (steel only) or ηϭϰ HD ǁith FlintFast ϯ͟ Insulation Plates or Trufast #12 (steel only) or HD with Trufast ϯ͟ Metal InsƵlation Plates 1 per 1.45 ft2 BP-AA, SBS-AA, SBS-TA or APP-TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -82.5 S-53 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete (Optional for Concrete or Recover) Min. 1.5-inch ACFoam II, FlintBoard, H-Shield Min. 0.5-inch Dens Deck Prime TrƵfast HD ǁith TrƵfast ϯ͟ Metal Insulation Plates or FlintFast ηϭϰ ǁith FlintFast ϯ͟ Insulation Plates 1 per 1.33 ft2 BP-AA, SBS-AA (Optional) BP-AA, SBS-AA SBS-AA -112.5 S-54 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 0.5-inch SECUROCK Gypsum-Fiber Roof Board FlintFast #12 (steel only) or ηϭϰ HD ǁith FlintFast ϯ͟ Insulation Plates or Trufast #12 (steel only) or HD with Trufast ϯ͟ Metal InsƵlation Plates 1 per 1 ft2 BP-AA, SBS-AA, SBS-TA or APP-TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -135.0 S-55 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete (Optional for Concrete or Recover) Min. 1.5-inch ACFoam II, FlintBoard, H-Shield Min. 0.5-inch SECUROCK Gypsum-Fiber Roof Board TrƵfast HD ǁith TrƵfast ϯ͟ Metal Insulation Plates or FlintFast ηϭϰ ǁith FlintFast ϯ͟ Insulation Plates 1 per 1.33 ft2 BP-AA, SBS-AA (Optional) BP-AA, SBS-AA SBS-AA -157.5 S-56 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete (Optional for Concrete or Recover) Min. 1.5-inch ACFoam II, FlintBoard, H-Shield Min. 0.5-inch Dens Deck Prime TrƵfast HD ǁith TrƵfast ϯ͟ Metal Insulation Plates or FlintFast ηϭϰ ǁith FlintFast ϯ͟ Insulation Plates 1 per 1 ft2 BP-AA, SBS-AA (Optional) BP-AA, SBS-AA SBS-AA -157.5 S-57 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete (Optional for Concrete or Recover) Min. 1.5-inch ACFoam II, FlintBoard, H-Shield Min. 0.5-inch SECUROCK Gypsum-Fiber Roof Board TrƵfast HD ǁith TrƵfast ϯ͟ Metal Insulation Plates or FlintFast ηϭϰ ǁith FlintFast ϯ͟ Insulation Plates 1 per 1 ft2 BP-AA, SBS-AA (Optional) BP-AA, SBS-AA SBS-AA -172.5 COLD-APPLIED SYSTEMS: S-58 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board FlintFast #12 (steel only) or ηϭϰ HD ǁith FlintFast ϯ͟ Insulation Plates or Trufast #12 (steel only) or HD with Trufast ϯ͟ Metal InsƵlation Plates 1 per 2.7 ft2 SBS-CA1 None SBS-CA1 -37.5* Exterior Research and Design, LLC. d/b/a Trinity|ERD Evaluation Report 3520.03.04-R20 for FL2533-R19 Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 20: 09/14/2017 Prepared by: Robert Nieminen, PE-59166 CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 651-5847 Appendix 1, Page 25 of 57 TABLE 2B: STEEL OR STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE C: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer(s) Top Insulation Layer Roof Cover (Note 14) MDP (psf) Type Fasteners Attach Base Ply Cap S-59 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 1.5-inch ACFoam III, FlintBoard Iso Cold, H-Shield CG or FlintBoard Iso ColdH FlintFast #12 (steel only) or ηϭϰ HD ǁith FlintFast ϯ͟ Insulation Plates or Trufast #12 (steel only) or HD with Trufast ϯ͟ Metal InsƵlation Plates 1 per 2 ft2 SBS-CA1 None SBS-CA1 -45.0* S-60 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 3/8-inch SECUROCK Gypsum-Fiber Roof Board FlintFast #12 (steel only) or ηϭϰ HD ǁith FlintFast ϯ͟ Insulation Plates or Trufast #12 (steel only) or HD with Trufast ϯ͟ Metal InsƵlation Plates 1 per 2.7 ft2 SBS-CA1 None SBS-CA1 -45.0* S-61 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 0.5-inch SECUROCK Gypsum-Fiber Roof Board FlintFast #12 (steel only) or ηϭϰ HD ǁith FlintFast ϯ͟ Insulation Plates or Trufast #12 (steel only) or HD with Trufast ϯ͟ Metal InsƵlation Plates 1 per 1.45 ft2 SBS-CA1 None SBS-CA1 -82.5* Exterior Research and Design, LLC. d/b/a Trinity|ERD Evaluation Report 3520.03.04-R20 for FL2533-R19 Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 20: 09/14/2017 Prepared by: Robert Nieminen, PE-59166 CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 651-5847 Appendix 1, Page 26 of 57 TABLE 2C: STEEL OR STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE D: INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER NOTE: INSULATION OPTIONAL FOR RECOVER OR CONCRETE DECK APPLICATIONS (NOTE 14) System No. Deck (Note 1) Insulation Layer(s) Base or Anchor Sheet Roof Cover (Note 14) MDP (psf) Type Attach Base Fasteners Attach Ply Cap SELF-ADHERING SYSTEMS: S-62 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 1.5-inch, One or more layers, any combination Prelim. Attached Flintlastic SA NailBase Note 2 9-inch o.c. at min. 2-inch lap and 18-inch o.c. in two (2), equally spaced, staggered center rows (Optional) SBS-SA SBS-SA -45.0* S-63 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 1.5-inch, One or more layers, any combination Prelim. Attached Flintlastic SA NailBase Note 2 12-inch o.c. at min. 2-inch lap and 12-inch o.c. in two (2), equally spaced, staggered center rows (Optional) SBS-SA SBS-SA -52.5* S-64 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 1.5-inch, One or more layers, any combination Prelim. Attached Flintlastic SA NailBase Note 2 12-inch o.c. at min. 4-inch lap and 12-inch o.c. in two (2), equally spaced, staggered center rows (Optional) SBS-SA SBS-SA -60.0* S-65 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 1.5-inch, One or more layers, any combination Prelim. Attached Flintlastic SA NailBase (laid parallel to deck flutes) Note 2 8-inch o.c. at min. 4-inch lap and 8-inch o.c. in two (2), equally spaced, staggered center rows (Optional) SBS-SA SBS-SA -82.5* CONVENTIONAL SYSTEMS: S-66 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 1.5-inch, One or more layers, any combination Prelim. Attached Glasbase; All Weather/Empire Base; Flexiglas Base; Flintlastic Base 20; Yosemite Note 2 12-inch o.c. at 4-inch lap and 36-inch o.c. in two (2), equally spaced, staggered center rows BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -30.0* S-67 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 1.5-inch, One or more layers, any combination Prelim. Attached Glasbase; All Weather/Empire Base; Flexiglas Base; Flintlastic Base 20; Yosemite Note 2 12-inch o.c. at 4-inch lap and 24-inch o.c. in two (2), equally spaced, staggered center rows BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -45.0* S-68 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 1.5-inch, One or more layers, any combination Prelim. Attached Poly SMS Base; Ultra Poly SMS Base Note 2 12-inch o.c. at 4-inch lap and 36-inch o.c. in two (2), equally spaced, staggered center rows BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -45.0* S-69 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 1.5-inch, One or more layers, any combination Prelim. Attached Poly SMS Base; Ultra Poly SMS Base Note 2 18-inch o.c. at 4-inch lap and 18-inch o.c. in one (1) staggered center row BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -45.0* S-70 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 1.5-inch, One or more layers, any combination Prelim. Attached Poly SMS Base; Ultra Poly SMS Base Dekfast IF-2-SB plates with #14 Dekfast 12-inch o.c. within the min. 4-inch wide, heat-welded side lap SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -45.0* S-71 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 1.5-inch, One or more layers, any combination Prelim. Attached Glasbase; Flexiglas Base; Flintlastic Base 20; All Weather / Empire Base; Poly SMS Base; Yosemite Note 2 12-inch o.c. at 3-inch lap and 12-inch o.c. in two (2), equally spaced, staggered center rows BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -52.5 Exterior Research and Design, LLC. d/b/a Trinity|ERD Evaluation Report 3520.03.04-R20 for FL2533-R19 Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 20: 09/14/2017 Prepared by: Robert Nieminen, PE-59166 CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 651-5847 Appendix 1, Page 27 of 57 TABLE 2C: STEEL OR STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE D: INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER NOTE: INSULATION OPTIONAL FOR RECOVER OR CONCRETE DECK APPLICATIONS (NOTE 14) System No. Deck (Note 1) Insulation Layer(s) Base or Anchor Sheet Roof Cover (Note 14) MDP (psf) Type Attach Base Fasteners Attach Ply Cap S-72 Min. 22 ga., type B, 40 ksi steel or min. 2,500 psi structrual concrete Min. 2-inch, One or more layers, any combination Prelim. Attached Ultra Poly SMS Base TrƵfast Ϯ͟ Barbed Metal Seam Plates with Trufast #15 EHD (steel only) or Trufast #14 HD (concrete only) 12-inch o.c. within the min. 4-inch wide, heat-welded side lap (Optional) SBS-TA or APP-TA SBS-TA or APP-TA -52.5 S-73 Min. 22 ga., type B, Grade 80 steel or min. 2,500 psi structrual concrete Min. 1.5-inch, One or more layers, any combination Prelim. Attached Ultra Poly SMS Base TrƵfast Ϯ͘ϰ͟ Barbed Metal Seam Plates with Trufast #15 EHD (steel only) or Trufast #14 HD (concrete only) 12-inch o.c. within the min. 4-inch wide, heat-welded side lap (Optional) SBS-TA or APP-TA SBS-TA or APP-TA -60.0 S-74 Min. 22 ga., type B, 40 ksi steel or min. 2,500 psi structrual concrete Min. 2-inch, One or more layers, any combination Prelim. Attached Ultra Poly SMS Base TrƵfast Ϯ͘ϰ͟ Scoop Seam Plates with Trufast #15 EHD (steel only) or Trufast #14 HD (concrete only) 12-inch o.c. within the min. 4-inch wide, heat-welded side lap (Optional) SBS-TA or APP-TA SBS-TA or APP-TA -67.5 S-75 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 1.5-inch, One or more layers, any combination Prelim. Attached Glasbase; Yosemite OMG Flat Bottom Plates with OMG #14 HD (Accutrac) 6-inch o.c. at 4-inch lap and 6-inch o.c. in two (2), equally spaced, staggered center rows BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -67.5 S-76 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 1.5-inch, One or more layers, any combination Prelim. Attached Flexiglas Base; Flintlastic Base 20; Yosemite Note 2 6-inch o.c. at 4-inch lap and 6-inch o.c. in two (2), equally spaced, staggered center rows BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -67.5 S-77 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 1.5-inch, One or more layers, any combination Prelim. Attach Glasbase; Flexiglas; Flintlastic Base 20; All Weather / Empire Base; Poly SMS Base; Ultra Poly SMS Base; Yosemite Flintfast 3 in. Insulation Plates with FlintFast #14; Trufast 3" Metal Insulation Plates with Trufast HD 6-inch o.c. at 4-inch lap and 6-inch o.c. at three (3) equally spaced, staggered center rows (Optional) BP-AA, SBS-AA or SBS-TA SBS-AA or SBS-TA -97.5 S-78 Min. 22 ga., type B, 40 ksi steel or min. 2,500 psi structrual concrete Min. 2-inch, One or more layers, any combination Prelim. Attached Ultra Poly SMS Base TrƵfast Ϯ͘ϰ͟ Scoop Seam Plates with Trufast #15 EHD (steel only) or Trufast #14 HD (concrete only) 6-inch o.c. within the min. 4-inch wide, heat-welded side lap (Optional) SBS-TA or APP-TA SBS-TA or APP-TA -112.5 S-79 Min. 22 ga., type B, Grade 80 steel or min. 2,500 psi structrual concrete Min. 1.5-inch, One or more layers, any combination Prelim. Attached Poly SMS Base; Ultra Poly SMS Base Note 2 12-inch o.c. at 4-inch lap and 12-inch o.c. in two (2), equally spaced, staggered center rows SBS-TA or APP-TA SBS-TA or APP-TA -112.5 S-80 Min. 22 ga., type B, Grade 80 steel or min. 2,500 psi structrual concrete Min. 1.5-inch, One or more layers, any combination Prelim. Attached Poly SMS Base; Ultra Poly SMS Base Note 2 12-inch o.c. at 4-inch lap and 12-inch o.c. in two (2), equally spaced, staggered center rows SBS-AA SBS-AA or SBS-TA -120.0 Exterior Research and Design, LLC. d/b/a Trinity|ERD Evaluation Report 3520.03.04-R20 for FL2533-R19 Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 20: 09/14/2017 Prepared by: Robert Nieminen, PE-59166 CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 651-5847 Appendix 1, Page 28 of 57 TABLE 2C: STEEL OR STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE D: INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER NOTE: INSULATION OPTIONAL FOR RECOVER OR CONCRETE DECK APPLICATIONS (NOTE 14) System No. Deck (Note 1) Insulation Layer(s) Base or Anchor Sheet Roof Cover (Note 14) MDP (psf) Type Attach Base Fasteners Attach Ply Cap S-81 Min. 22 ga., type B, 40 ksi steel or min. 2,500 psi structrual concrete Min. 2-inch, One or more layers, any combination Prelim. Attached Ultra Poly SMS Base Trufast Ϯ͘ϰ͟ Scoop Seam Plates with Trufast #15 EHD (steel only) or Trufast #14 HD (concrete only) 6-inch o.c. within the min. 4-inch wide, heat-welded side laps and 6-inch o.c. in one (1) center row, stripped-in with 6-inch side strips of torch-applied Poly SMS Base or Ultra Poly SMS Base. (Optional) SBS-TA or APP-TA SBS-TA or APP-TA -165.0 COLD-APPLIED SYSTEMS: S-82 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 1.5-inch, One or more layers, any combination Prelim. Attached Glasbase; All Weather/Empire Base; Flexiglas Base; Flintlastic Base 20 Note 2 6-inch o.c. at 4-inch lap and 12-inch o.c. in two (2), equally spaced, staggered center rows SBS-CA1 SBS-CA1 -45.0* S-83 Min. 22 ga., type B, Grade 40 steel or min. 2,500 psi structrual concrete Min. 1-inch, One or more layers, any combination Loose-laid Glasbase; Flexiglas Base; Flintlastic Base 20; All Weather / Empire Base; Yosemite Venting Base; Flintlastic Poly SMS Base; Flintlastic Ultra Poly SMS Base FlintFast #14 HD with FlintFast ϯ͟ Insulation Plates or Trufast HD with TrƵfast ϯ͟ Metal InsƵlation Plates 6-inch o.c. at 4-inch lap and 12-inch o.c. in three (3), equally spaced, staggered center rows (Optional) SBS-CA1 SBS-CA1 -75.0 Exterior Research and Design, LLC. d/b/a Trinity|ERD Evaluation Report 3520.03.04-R20 for FL2533-R19 Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 20: 09/14/2017 Prepared by: Robert Nieminen, PE-59166 CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 651-5847 Appendix 1, Page 29 of 57 TABLE 3A: STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER Sys. No. Deck (Note 1) Primer Base Insulation Layer Top Insulation Layer Roof Cover (Note 14) MDP (psf) Type Attach Type Attach Base Ply Cap SELF-ADHERING SYSTEMS: C-1. Structural concrete FlintPrime (ASTM D41) Min. 1.5-inch ACFoam II, FlintBoard, ENRGY 3 or H-Shield HA Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board HA SBS-SA (Optional) SBS-SA SBS-SA -172.5 C-2. Structural concrete FlintPrime (ASTM D41) Min. 1.5-inch ACFoam II, FlintBoard, ENRGY 3 or Multi-Max FA3 HA Min. 0.25-inch Dens Deck primed with FlintPrime or FlintPrime SA HA SBS-SA (Optional) SBS-SA SBS-SA -192.5 C-3. Structural concrete None Min. 1.5-inch ACFoam II, FlintBoard, ENRGY 3 or Multi-Max FA3 A-PD Min. 0.25-inch Dens Deck primed with FlintPrime or FlintPrime SA A-PD SBS-SA (Optional) SBS-SA SBS-SA -105.0 C-4. Structural concrete None Min. 1.5-inch ACFoam II, FlintBoard, ENRGY 3 or H-Shield A-PD Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board A-PD SBS-SA (Optional) SBS-SA SBS-SA -172.5 C-5. Structural concrete None Min. 1.5-inch ACFoam II, FlintBoard, ENRGY 3 or Multi-Max FA3 A-PD 6-inch o.c. Min. 0.25-inch Dens Deck primed with FlintPrime or FlintPrime SA A-PD 6-inch o.c. SBS-SA (Optional) SBS-SA SBS-SA -192.5 C-6. Structural concrete (Optional) FlintPrime (ASTM D41) Min. 1.5-inch Multi-Max FA D-IS Min. 0.25-inch Dens Deck primed with FlintPrime or FlintPrime SA D-IS SBS-SA (Optional) SBS-SA SBS-SA -67.5 C-7. Structural concrete (Optional) FlintPrime (ASTM D41) Min. 1.5-inch ENRGY 3 D-IS Min. 0.25-inch Dens Deck primed with FlintPrime or FlintPrime SA D-IS SBS-SA (Optional) SBS-SA SBS-SA -112.5 C-8. Structural concrete (Optional) FlintPrime (ASTM D41) Min. 1.5-inch ACFoam II or FlintBoard D-IS Min. 0.25-inch Dens Deck primed with FlintPrime or FlintPrime SA D-IS SBS-SA (Optional) SBS-SA SBS-SA -120.0 C-9. Structural concrete None Min. 1.5-inch ACFoam II, FlintBoard, ENRGY 3 or H-Shield D-IS Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board D-IS SBS-SA (Optional) SBS-SA SBS-SA -172.5 C-10. Structural concrete None Min. 1.5-inch ACFoam II, FlintBoard, ENRGY 3 or H-Shield M-OSFA or M-PG1 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board M-OSFA or M-PG1 SBS-SA (Optional) SBS-SA SBS-SA -172.5 C-11. Structural concrete None Min. 1.5-inch ACFoam II, FlintBoard, ENRGY 3 or Multi-Max FA M-OSFA or M-PG1 Min. 0.25-inch Dens Deck primed with FlintPrime or FlintPrime SA M-OSFA or M-PG1 SBS-SA (Optional) SBS-SA SBS-SA -192.5 C-12. Structural concrete FlintPrime (ASTM D41) Min. 1.5-inch ACFoam II, FlintBoard ISO or ENRGY 3 OB500 Min. 0.25-inch Dens Deck primed with FlintPrime or FlintPrime SA OB500 SBS-SA (Optional) SBS-SA SBS-SA -120.0 C-13. Structural concrete None Min. 1.5-inch ACFoam II, FlintBoard ISO or ENRGY 3 OB500 Min. 0.25-inch Dens Deck primed with FlintPrime or FlintPrime SA OB500 SBS-SA (Optional) SBS-SA SBS-SA -150.0 C-14. Structural concrete None Min. 1.5-inch ACFoam II, FlintBoard, ENRGY 3 or H-Shield OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 SBS-SA (Optional) SBS-SA SBS-SA -172.5 C-15. Structural concrete None Min. 1.0-inch ISO 95+ GL, H-Shield, H-Shield CG, ENRGY 3 or min. 1.3-inch ACFoam III, Min. 1.5-inch Multi-Max FA3 or Ultra-Max CR-20 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board CR-20 SBS-SA (Optional) SBS-SA SBS-SA -172.5 Exterior Research and Design, LLC. d/b/a Trinity|ERD Evaluation Report 3520.03.04-R20 for FL2533-R19 Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 20: 09/14/2017 Prepared by: Robert Nieminen, PE-59166 CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 651-5847 Appendix 1, Page 30 of 57 TABLE 3A: STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER Sys. No. Deck (Note 1) Primer Base Insulation Layer Top Insulation Layer Roof Cover (Note 14) MDP (psf) Type Attach Type Attach Base Ply Cap C-16. Structural concrete None Min. 1.0-inch ISO 95+ GL, H-Shield, H-Shield CG, ENRGY 3 or min. 1.3-inch ACFoam III, Min. 1.5-inch Multi-Max FA3 or Ultra-Max CR-20 Min. 0.25-inch Dens Deck primed with FlintPrime or FlintPrime SA CR-20 SBS-SA (Optional) SBS-SA SBS-SA -192.5 HYBRID SYSTEMS: C-17. Structural concrete FlintPrime (ASTM D41) Min. 1.5-inch ACFoam II, FlintBoard ISO, H-Shield, FlintBoard ISOH HA (Optional) Additional layer(s) base insulation HA Flintlastic Ultra Glass SA (Optional) SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -322.5 C-18. Structural concrete FlintPrime (ASTM D41) Min. 1.5-inch ACFoam II, FlintBoard ISO, H-Shield, FlintBoard ISOH HA (Optional) Additional layer(s) base insulation HA Black Diamond Base Sheet (Optional) SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -375.0 C-19. Structural concrete None Min. 1.5-inch ACFoam II, FlintBoard ISO, H-Shield, FlintBoard ISOH A-PD (Optional) Additional layer(s) base insulation A-PD SBS-SA-H (Optional) SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -180.0 C-20. Structural concrete None Min. 1.5-inch ACFoam II, FlintBoard ISO, H-Shield, FlintBoard ISOH A-PD Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board A-PD SBS-SA-H (Optional) SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -117.5 C-21. Structural concrete None Min. 1.5-inch ACFoam II, FlintBoard ISO, H-Shield, FlintBoard ISOH A-PD, 6-inch o.c. Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board A-PD, 6-inch o.c. SBS-SA-H (Optional) SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -217.5 C-22. Structural concrete None Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board A-PD, 6-inch o.c. None N/A SBS-SA-H (Optional) SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -195.0 C-23. Structural concrete None Min. 1.5-inch ACFoam II, FlintBoard ISO, H-Shield, FlintBoard ISOH D-IS (Optional) Additional layer(s) base insulation D-IS SBS-SA-H (Optional) SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -135.0 C-24. Structural concrete None Min. 1.5-inch ACFoam II, FlintBoard ISO, H-Shield, FlintBoard ISOH D-IS Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board D-IS SBS-SA-H (Optional) SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -217.5 C-25. Structural concrete None Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board D-IS None N/A SBS-SA-H (Optional) SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -195.0 C-26. Structural concrete None Min. 1.5-inch ACFoam II, FlintBoard ISO, H-Shield, FlintBoard ISOH M-OSFA (Optional) Additional layer(s) base insulation M-OSFA SBS-SA-H (Optional) SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -232.5 C-27. Structural concrete None Min. 1.5-inch ACFoam II, FlintBoard ISO, H-Shield, FlintBoard ISOH M-OSFA Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board M-OSFA SBS-SA-H (Optional) SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -217.5 C-28. Structural concrete None Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board M-OSFA None N/A SBS-SA-H (Optional) SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -195.0 C-29. Structural concrete None Min. 1.5-inch ACFoam II, FlintBoard ISO, H-Shield, FlintBoard ISOH M-PG1 (Optional) Additional layer(s) base insulation M-PG1 SBS-SA-H (Optional) SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -270.0 C-30. Structural concrete None Min. 1.5-inch ACFoam II, FlintBoard ISO, H-Shield, FlintBoard ISOH M-PG1 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board M-PG1 SBS-SA-H (Optional) SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -217.5 C-31. Structural concrete None Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board M-PG1 None N/A SBS-SA-H (Optional) SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -195.0 Exterior Research and Design, LLC. d/b/a Trinity|ERD Evaluation Report 3520.03.04-R20 for FL2533-R19 Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 20: 09/14/2017 Prepared by: Robert Nieminen, PE-59166 CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 651-5847 Appendix 1, Page 31 of 57 TABLE 3A: STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER Sys. No. Deck (Note 1) Primer Base Insulation Layer Top Insulation Layer Roof Cover (Note 14) MDP (psf) Type Attach Type Attach Base Ply Cap C-32. Structural concrete None Min. 1.5-inch ACFoam II, FlintBoard ISO, H-Shield, FlintBoard ISOH OB500 (Optional) Additional layer(s) base insulation OB500 SBS-SA-H (Optional) SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -135.0 C-33. Structural concrete None Min. 1.5-inch ACFoam II, FlintBoard ISO, H-Shield, FlintBoard ISOH OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 SBS-SA-H (Optional) SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -217.5 C-34. Structural concrete None Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 None N/A SBS-SA-H (Optional) SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -195.0 C-35. Structural concrete None Min. 1.5-inch ACFoam II, FlintBoard ISO, H-Shield, FlintBoard ISOH CR-20 (Optional) Additional layer(s) base insulation CR-20 SBS-SA-H (Optional) SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -270.0 C-36. Structural concrete None Min. 1.5-inch ACFoam II, FlintBoard ISO, H-Shield, FlintBoard ISOH CR-20 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board CR-20 SBS-SA-H (Optional) SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -217.5 C-37. Structural concrete None Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board CR-20 None N/A SBS-SA-H (Optional) SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -195.0 CONVENTIONAL SYSTEMS: C-38. Structural concrete FlintPrime (ASTM D41) Min. 1.5-inch ACFoam II, ENRGY 3, H-Shield, FlintBoard ISO HA (Optional) Additional layer(s) of base insulation HA BP-AA3, 24-inch grid (Optional) BP-AA, SBS-AA SBS-AA -37.5 C-39. Structural concrete FlintPrime (ASTM D41) Min. 1.5-inch ACFoam II or FlintBoard ISO. HA Min. 0.25-inch Dens Deck, Dens Deck Prime HA SBS-TA (Optional) SBS-TA SBS-TA -180.0 C-40. Structural concrete FlintPrime (ASTM D41) (Optional) Min. 1.5-inch ACFoam II or FlintBoard ISO. HA Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board HA BP-AA, SBS-AA, SBS-TA or APP-TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -180.0 C-41. Structural concrete FlintPrime (ASTM D41) (Optional) Min. 2-inch ACFoam II, FlintBoard ISO, ENRGY 3 or H-Shield HA Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board HA BP-AA or SBS-AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -225.0 C-42. Structural concrete FlintPrime (ASTM D41) (Optional) Min. 1.5-inch ACFoam II, FlintBoard ISO, H-Shield, FlintBoard ISOH HA Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board HA APP-TA (Optional) APP-TA APP-TA -252.5 C-43. Structural concrete FlintPrime (ASTM D41) Min. 1.5-inch ACFoam II, FlintBoard ISO, ENRGY 3 or H-Shield HA Min. 0.5-inch Structodek High Density Fiberboard HA BP-AA or SBS-AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -227.0 C-44. Structural concrete FlintPrime (ASTM D41) (Optional) Min. 2-inch ACFoam II, FlintBoard ISO, ENRGY 3 or H-Shield HA Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board HA SBS-TA or APP-TA (Optional) SBS-TA or APP-TA SBS-TA or APP-TA -232.5 C-45. Structural concrete FlintPrime (ASTM D41) Min. 1.5-inch ACFoam II, FlintBoard ISO, ENRGY 3 or H-Shield HA Min. 0.25-inch Dens Deck HA BP-AA or SBS-AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -240.0 C-46. Structural concrete FlintPrime (ASTM D41) Min. 1.5-inch ACFoam II or FlintBoard ISO HA Min. 0.75-inch FescoBoard (homogeneous) HA BP-AA or SBS-AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -412.0 Exterior Research and Design, LLC. d/b/a Trinity|ERD Evaluation Report 3520.03.04-R20 for FL2533-R19 Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 20: 09/14/2017 Prepared by: Robert Nieminen, PE-59166 CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 651-5847 Appendix 1, Page 32 of 57 TABLE 3A: STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER Sys. No. Deck (Note 1) Primer Base Insulation Layer Top Insulation Layer Roof Cover (Note 14) MDP (psf) Type Attach Type Attach Base Ply Cap C-47. Structural concrete FlintPrime (ASTM D41) Min. 1.5-inch ACFoam II or FlintBoard ISO HA Min. 0.5-inch DuraBoard (homogeneous) HA BP-AA or SBS-AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -430.0 C-48. Structural concrete FlintPrime (ASTM D41) 0.5-inch Structodek High Density Fiberboard or min. 0.75-inch Fesco Board (homogeneous) HA None N/A BP-AA (Optional) BP-AA or SBS-AA SBS-AA -437.5 C-49. Structural concrete FlintPrime (ASTM D41) 0.25-inch Dens Deck, Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board HA None N/A SBS-TA (Optional) SBS-AA or SBS-TA SBS-AA or SBS-TA -302.5 C-50. Structural concrete FlintPrime (ASTM D41) Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board HA None N/A Flintlastic Ultra Poly SMS Base, torched (Optional) Flintlastic Ultra Poly SMS Base, torched SBS-TA -487.5 C-51. Structural concrete FlintPrime (ASTM D41) 0.25-inch Dens Deck, Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board HA None N/A BP-AA (Optional) BP-AA or SBS-AA SBS-AA -537.5 C-52. Structural concrete None Min. 1.5-inch ACFoam II, FlintBoard ISO, ENRGY 3 or H-Shield A-PD Min. 0.5-inch Structodek High Density Fiberboard or Min. 0.25-inch Dens Deck A-PD BP-AA or SBS-AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -105.0 C-53. Structural concrete None Min. 1.5-inch ACFoam II, FlintBoard ISO, ENRGY 3 or H-Shield A-PD 6-inch o.c. Min. 0.5-inch Structodek High Density Fiberboard or Min. 0.25-inch Dens Deck A-PD 6-inch o.c. BP-AA or SBS-AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -217.5 C-54. Structural concrete None Min. 1.5-inch ACFoam II, FlintBoard ISO, H-Shield, FlintBoard ISOH A-PD Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board A-PD BP-AA, SBS-AA, SBS-TA or APP-TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -117.5 C-55. Structural concrete None Min. 1.5-inch ACFoam II, FlintBoard ISO, H-Shield, FlintBoard ISOH A-PD, 6-inch o.c. Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board A-PD, 6-inch o.c. BP-AA, SBS-AA, SBS-TA or APP-TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -217.5 C-56. Structural concrete None 0.5-inch Structodek High Density Fiberboard A-PD, 6-inch o.c. None N/A BP-AA, SBS-AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -195.0 C-57. Structural concrete None Min. 0.25-inch Dens Deck, Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board A-PD, 6-inch o.c. None N/A BP-AA, SBS-AA, SBS-TA or APP-TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -195.0 C-58. Structural concrete None Min. 1.5-inch ACFoam II or FlintBoard ISO. D-IS Min. 0.25-inch Dens Deck D-IS SBS-TA (Optional) SBS-TA SBS-TA -112.5 C-59. Structural concrete None Min. 1.5-inch ACFoam II, FlintBoard ISO, H-Shield, FlintBoard ISOH D-IS Min. 0.25-inch Dens Deck Prime D-IS BP-AA, SBS-AA (Optional) BP-AA, SBS-AA or SBS-TA SBS-AA or SBS-TA -297.5 C-60. Structural concrete None Min. 1.5-inch ACFoam II, FlintBoard ISO, H-Shield, FlintBoard ISOH D-IS Min. 0.25-inch Dens Deck Prime D-IS SBS-TA (Optional) SBS-TA SBS-TA -302.5 Exterior Research and Design, LLC. d/b/a Trinity|ERD Evaluation Report 3520.03.04-R20 for FL2533-R19 Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 20: 09/14/2017 Prepared by: Robert Nieminen, PE-59166 CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 651-5847 Appendix 1, Page 33 of 57 TABLE 3A: STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER Sys. No. Deck (Note 1) Primer Base Insulation Layer Top Insulation Layer Roof Cover (Note 14) MDP (psf) Type Attach Type Attach Base Ply Cap C-61. Structural concrete None Min. 2-inch ACFoam II, FlintBoard ISO, ENRGY 3 or H-Shield D-IS Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board D-IS BP-AA or SBS-AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -225.0 C-62. Structural concrete None Min. 2-inch ACFoam II, FlintBoard ISO, ENRGY 3 or H-Shield D-IS Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board D-IS SBS-TA or APP-TA (Optional) SBS-TA or APP-TA SBS-TA or APP-TA -232.5 C-63. Structural concrete None Min. 1.5-inch ACFoam II, FlintBoard ISO, H-Shield, FlintBoard ISOH D-IS Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board D-IS APP-TA (Optional) APP-TA APP-TA -252.5 C-64. Structural concrete None Min. 1.5-inch ACFoam II, FlintBoard ISO, H-Shield, FlintBoard ISOH D-IS Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board D-IS BP-AA, SBS-AA or SBS-TA (Optional) BP-AA, SBS-AA or SBS-TA SBS-AA or SBS-TA -297.5 C-65. Structural concrete None 0.5-inch Structodek High Density Fiberboard D-IS None N/A BP-AA, SBS-AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -195.0 C-66. Structural concrete None Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board D-IS None N/A BP-AA, SBS-AA, SBS-TA or APP-TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -195.0 C-67. Structural concrete None Min. 1.5-inch ACFoam II, FlintBoard ISO, ENRGY 3 or H-Shield M-OSFA Min. 0.5-inch Structodek High Density Fiberboard M-OSFA BP-AA or SBS-AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -127.5 C-68. Structural concrete None Min. 1.5-inch ACFoam II, FlintBoard ISO, ENRGY 3 or H-Shield M-PG1 Min. 0.5-inch Structodek High Density Fiberboard M-PG1 BP-AA or SBS-AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -180.0 C-69. Structural concrete None Min. 1.5-inch ACFoam II, FlintBoard ISO, ENRGY 3 or H-Shield M-OSFA Min. 0.25-inch Dens Deck M-OSFA BP-AA or SBS-AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -232.5 C-70. Structural concrete None Min. 1.5-inch ACFoam II, FlintBoard ISO, ENRGY 3 or H-Shield M-PG1 Min. 0.25-inch Dens Deck M-PG1 BP-AA or SBS-AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -240.0 C-71. Structural concrete None Min. 1.5-inch ACFoam II, FlintBoard ISO, H-Shield, FlintBoard ISOH M-PG1 Min. 0.25-inch Dens Deck Prime M-PG1 BP-AA, SBS-AA (Optional) BP-AA, SBS-AA or SBS-TA SBS-AA or SBS-TA -297.5 C-72. Structural concrete None Min. 1.5-inch ACFoam II, FlintBoard ISO, H-Shield, FlintBoard ISOH M-PG1 Min. 0.25-inch Dens Deck Prime M-PG1 SBS-TA (Optional) SBS-TA SBS-TA -302.5 C-73. Structural concrete None Min. 2-inch ACFoam II, FlintBoard ISO, ENRGY 3 or H-Shield M-OSFA or M-PG1 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board M-OSFA or M-PG1 BP-AA or SBS-AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -225.0 C-74. Structural concrete None Min. 2-inch ACFoam II, FlintBoard ISO, ENRGY 3 or H-Shield M-OSFA or M-PG1 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board M-OSFA or M-PG1 SBS-TA or APP-TA (Optional) SBS-TA or APP-TA SBS-TA or APP-TA -232.5 Exterior Research and Design, LLC. d/b/a Trinity|ERD Evaluation Report 3520.03.04-R20 for FL2533-R19 Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 20: 09/14/2017 Prepared by: Robert Nieminen, PE-59166 CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 651-5847 Appendix 1, Page 34 of 57 TABLE 3A: STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER Sys. No. Deck (Note 1) Primer Base Insulation Layer Top Insulation Layer Roof Cover (Note 14) MDP (psf) Type Attach Type Attach Base Ply Cap C-75. Structural concrete None Min. 1.5-inch ACFoam II, FlintBoard ISO, H-Shield, FlintBoard ISOH M-OSFA or M-PG1 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board M-OSFA or M-PG1 APP-TA (Optional) APP-TA APP-TA -252.5 C-76. Structural concrete None Min. 1.5-inch ACFoam II, FlintBoard ISO, H-Shield, FlintBoard ISOH M-OSFA or M-PG1 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board M-OSFA or M-PG1 BP-AA, SBS-AA or SBS-TA (Optional) BP-AA, SBS-AA or SBS-TA SBS-AA or SBS-TA -297.5 C-77. Structural concrete None 0.5-inch Structodek High Density Fiberboard M-PG1 None N/A BP-AA, SBS-AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -195.0 C-78. Structural concrete None Min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board M-PG1 None N/A BP-AA, SBS-AA, SBS-TA or APP-TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -195.0 C-79. Structural concrete None Min. 1.5-inch ACFoam II, FlintBoard ISO, ENRGY 3 or H-Shield OB500 Min. 0.5-inch Structodek High Density Fiberboard OB500 BP-AA or SBS-AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -120.0 C-80. Structural concrete None Min. 1.5-inch ACFoam II or FlintBoard ISO. OB500 Min. 0.25-inch Dens Deck or Dens Deck Prime OB500 BP-AA, SBS-AA, SBS-TA or APP-TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -150.0 C-81. Structural concrete None Min. 1.5-inch ACFoam II, FlintBoard ISO, H-Shield, FlintBoard ISOH OB500 Min. 0.25-inch Dens Deck Prime OB500 BP-AA, SBS-AA or SBS-TA (Optional) BP-AA, SBS-AA or SBS-TA SBS-AA or SBS-TA -297.5 C-82. Structural concrete None Min. 2-inch ACFoam II, FlintBoard ISO, ENRGY 3 or H-Shield OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 BP-AA or SBS-AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -225.0 C-83. Structural concrete None Min. 2-inch ACFoam II, FlintBoard ISO, ENRGY 3 or H-Shield OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 SBS-TA or APP-TA (Optional) SBS-TA or APP-TA SBS-TA or APP-TA -232.5 C-84. Structural concrete None Min. 1.5-inch ACFoam II, FlintBoard ISO, H-Shield, FlintBoard ISOH OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 APP-TA (Optional) APP-TA APP-TA -252.5 C-85. Structural concrete None Min. 1.5-inch ACFoam II, FlintBoard ISO, H-Shield, FlintBoard ISOH OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 BP-AA, SBS-AA or SBS-TA (Optional) BP-AA, SBS-AA or SBS-TA SBS-AA or SBS-TA -297.5 C-86. Structural concrete None 0.5-inch Structodek High Density Fiberboard OB500 None N/A BP-AA, SBS-AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -195.0 C-87. Structural concrete None Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 None N/A BP-AA, SBS-AA, SBS-TA or APP-TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -195.0 Exterior Research and Design, LLC. d/b/a Trinity|ERD Evaluation Report 3520.03.04-R20 for FL2533-R19 Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 20: 09/14/2017 Prepared by: Robert Nieminen, PE-59166 CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 651-5847 Appendix 1, Page 35 of 57 TABLE 3A: STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER Sys. No. Deck (Note 1) Primer Base Insulation Layer Top Insulation Layer Roof Cover (Note 14) MDP (psf) Type Attach Type Attach Base Ply Cap C-88. Structural concrete None Min. 1.0-inch ISO 95+ GL, H-Shield, H-Shield CG, ENRGY 3 or min. 1.3-inch ACFoam III, Min. 1.5-inch Multi-Max FA3 or Ultra-Max CR-20 Min. 0.5-inch Structodek High Density Fiberboard or DuraBoard (homogeneous) or min. 1.5-inch FescoBoard (laminated) CR-20 BP-AA or SBS-AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -180.0 C-89. Structural concrete None Min. 1.0-inch ISO 95+ GL, H-Shield, H-Shield CG, ENRGY 3 or min. 1.3-inch ACFoam III, Min. 1.5-inch Multi-Max FA3 or Ultra- CR-20 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board CR-20 BP-AA or SBS-AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -225.0 C-90. Structural concrete None Min. 1.0-inch ISO 95+ GL, H-Shield, H-Shield CG, ENRGY 3 or min. 1.3-inch ACFoam III, Min. 1.5-inch Multi-Max FA3 or Ultra-Max CR-20 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board CR-20 SBS-TA or APP-TA (Optional) SBS-TA or APP-TA SBS-TA or APP-TA -232.5 C-91. Structural concrete None Min. 1.0-inch ISO 95+ GL, H-Shield, H-Shield CG, ENRGY 3 or min. 1.3-inch ACFoam III, Min. 1.5-inch Multi-Max FA3 or Ultra-Max CR-20 Min. 0.25-inch Dens Deck CR-20 BP-AA or SBS-AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -240.0 C-92. Structural concrete None 0.5-inch Structodek High Density Fiberboard CR-20 None N/A BP-AA, SBS-AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -195.0 C-93. Structural concrete None Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board CR-20 None N/A BP-AA, SBS-AA, SBS-TA or APP-TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -195.0 COLD-APPLIED SYSTEMS: C-94. Structural concrete None (Optional) Min. 0.5-inch ACFoam II, FlintBoard ISO, H-Shield, FlintBoard ISOH OB500 or CR-20 Min. 1.5-inch ACFoam III, FlintBoard Iso Cold, H-Shield CG or FlintBoard Iso ColdH OB500 or CR-20 SBS-CA1 None SBS-CA1 -82.5 C-95. Structural concrete None Min. 0.5-inch ACFoam II, FlintBoard ISO, H-Shield, FlintBoard ISOH A-PD, D-IS, M-OSFA, M-PG1, OB500 or CR-20 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board A-PD, D-IS, M-OSFA, M-PG1, OB500 or CR-20 SBS-CA1 None SBS-CA1 -105.0 TABLE 3B: STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-3: BONDED TEMP ROOF, BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Primer / Temp Roof Base Insulation Layer Top Insulation Layer Roof Cover (Note 14) MDP (psf) Type Attach Type Attach Base Ply Cap COLD-APPLIED SYSTEMS: Exterior Research and Design, LLC. d/b/a Trinity|ERD Evaluation Report 3520.03.04-R20 for FL2533-R19 Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 20: 09/14/2017 Prepared by: Robert Nieminen, PE-59166 CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 651-5847 Appendix 1, Page 36 of 57 TABLE 3B: STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-3: BONDED TEMP ROOF, BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Primer / Temp Roof Base Insulation Layer Top Insulation Layer Roof Cover (Note 14) MDP (psf) Type Attach Type Attach Base Ply Cap C-96. Structural concrete FlintPrime (ASTM D41) Flintlastic SA PlyBase, self-adhered (Optional) Min. 0.5-inch ACFoam II, FlintBoard ISO, H-Shield, FlintBoard ISOH OB500 Min. 1.5-inch ACFoam III, FlintBoard Iso Cold, H-Shield CG or FlintBoard Iso ColdH OB500 SBS-CA1 None SBS-CA1 -82.5 C-97. Structural concrete FlintPrime (ASTM D41) Flintlastic SA PlyBase, self-adhered Min. 0.5-inch ACFoam II, FlintBoard ISO, H-Shield, FlintBoard ISOH OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 SBS-CA1 None SBS-CA1 -82.5 Exterior Research and Design, LLC. d/b/a Trinity|ERD Evaluation Report 3520.03.04-R20 for FL2533-R19 Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 20: 09/14/2017 Prepared by: Robert Nieminen, PE-59166 CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 651-5847 Appendix 1, Page 37 of 57 TABLE 3C: STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE F: NON-INSULATED, BONDED ROOF COVER System No. Deck (Note 1) Primer Roof Cover (Note 14) MDP (psf) Base Ply Cap SELF-ADHERING SYSTEMS: C-98. Structural concrete FlintPrime SA SBS-SA (Optional) SBS-SA SBS-SA -555.0 C-99. Structural concrete FlintPrime (ASTM D41) SBS-SA (Optional) SBS-SA SBS-SA -630.0 HYBRID SYSTEMS: C-100. Structural concrete FlintPrime SA Flintlastic Ultra Glass SA (Optional) SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -52.5 C-101. Structural concrete FlintPrime (ASTM D41) Flintlastic Ultra Glass SA (Optional) SBS-AA SBS-AA -135.0 C-102. Structural concrete FlintPrime (ASTM D41) Black Diamond Base Sheet (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -150.0 C-103. Structural concrete FlintPrime (ASTM D41) Flintlastic Ultra Glass SA (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -322.5 C-104. Structural concrete FlintPrime (ASTM D41) Black Diamond Base Sheet (Optional) BP-AA, SBS-AA SBS-AA -240.0 C-105. Structural concrete FlintPrime (ASTM D41) BP-AA, SBS-AA SBS-SA-H SBS-AA, SBS-TA, APP-TA -635.0 CONVENTIONAL SYSTEMS: C-106. Structural concrete FlintPrime (ASTM D41) APP-TA (Optional) APP-TA APP-TA -420.0 C-107. Structural concrete FlintPrime (ASTM D41) SBS-TA (Optional) SBS-TA SBS-TA -542.5 C-108. Structural concrete FlintPrime (ASTM D41) BP-AA, SBS-AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -635.0 COLD-APPLIED SYSTEMS: C-109. Structural concrete FlintPrime (ASTM D41) SBS-CA1 (Optional) SBS-CA1 SBS-CA1 -262.5 Exterior Research and Design, LLC. d/b/a Trinity|ERD Evaluation Report 3520.03.04-R20 for FL2533-R19 Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 20: 09/14/2017 Prepared by: Robert Nieminen, PE-59166 CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 651-5847 Appendix 1, Page 38 of 57 TABLE 4A: LIGHTWEIGHT CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Lightweight Concrete (Note 13) Base Insulation Layer Coverboard Roof Cover (Note 14) MDP (psf) Type Attach Type Attach Base Ply Cap SELF-ADHERING SYSTEMS: LWC-1 Concrete Min. 200 psi, min. 2-inch Elastizell Min. 1.5-inch ACFoam II, FlintBoard, ENRGY 3 or H-Shield A-PD, 6-inch o.c. Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board A-PD, 6-inch o.c. SBS-SA (Optional) SBS-SA SBS-SA -172.5 LWC-2 Concrete Min. 200 psi, min. 2-inch Elastizell Min. 1.5-inch ACFoam II, FlintBoard, ENRGY 3 or Multi-Max FA3 A-PD, 6-inch o.c. Min. 0.25-inch Dens Deck primed with FlintPrime or FlintPrime SA A-PD, 6-inch o.c. SBS-SA (Optional) SBS-SA SBS-SA -187.5 LWC-3 Concrete Min. 200 psi, min. 2-inch Elastizell Min. 1.5-inch ACFoam II, FlintBoard ISO or ENRGY 3 OB500 Min. 0.25-inch Dens Deck primed with FlintPrime or FlintPrime SA OB500 SBS-SA (Optional) SBS-SA SBS-SA -150.0 LWC-4 Concrete Min. 200 psi, min. 2-inch Elastizell Min. 1.5-inch ACFoam II, FlintBoard, ENRGY 3 or H-Shield OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 SBS-SA (Optional) SBS-SA SBS-SA -172.5 LWC-5 Concrete Min. 200 psi, min. 2-inch Celcore, Elastizell or Celcore Min. 1.0-inch ISO 95+ GL, H-Shield, H-Shield CG, ENRGY 3 or min. 1.3-inch ACFoam III, Min. 1.5-inch Multi-Max FA3 or Ultra-Max CR-20 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board CR-20 SBS-SA (Optional) SBS-SA SBS-SA -172.5 LWC-6 Concrete Min. 200 psi, min. 2-inch Celcore, Elastizell or Celcore Min. 1.0-inch ISO 95+ GL, H-Shield, H-Shield CG, ENRGY 3 or min. 1.3-inch ACFoam III, Min. 1.5-inch Multi-Max FA3 or Ultra-Max CR-20 Min. 0.25-inch Dens Deck primed with FlintPrime or FlintPrime SA CR-20 SBS-SA (Optional) SBS-SA SBS-SA -180.0 CONVENTIONAL SYSTEMS: LWC-7 Concrete Min. 200 psi, min. 2-inch Elastizell Min. 1.5-inch ACFoam II, FlintBoard ISO, ENRGY 3 or H-Shield A-PD 6-inch o.c. Min. 0.5-inch Structodek High Density Fiberboard or Min. 0.25-inch Dens Deck A-PD 6-inch o.c. BP-AA or SBS-AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -187.5 LWC-8 Concrete Min. 200 psi, min. 2-inch Elastizell Min. 1.5-inch ACFoam II, FlintBoard ISO, ENRGY 3 or H-Shield A-PD, 6-inch o.c. Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board A-PD, 6-inch o.c. BP-AA or SBS-AA, SBS-TA or APP-TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -217.5 LWC-9 Concrete Min. 200 psi, min. 2-inch Elastizell Min. 1.5-inch ACFoam II or FlintBoard ISO. OB500 Min. 0.25-inch Dens Deck or Dens Deck Prime OB500 BP-AA, SBS-AA, SBS-TA or APP-TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -150.0 LWC-10 Concrete Min. 200 psi, min. 2-inch Elastizell Min. 1.5-inch ACFoam II or FlintBoard ISO. OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 SBS-TA (Optional) SBS-TA SBS-TA -180.0 LWC-11 Concrete Min. 200 psi, min. 2-inch Elastizell Min. 2-inch ACFoam II, FlintBoard ISO, ENRGY 3 or H-Shield OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 BP-AA, SBS-AA, SBS-TA or APP-TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -225.0 Exterior Research and Design, LLC. d/b/a Trinity|ERD Evaluation Report 3520.03.04-R20 for FL2533-R19 Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 20: 09/14/2017 Prepared by: Robert Nieminen, PE-59166 CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 651-5847 Appendix 1, Page 39 of 57 TABLE 4A: LIGHTWEIGHT CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Lightweight Concrete (Note 13) Base Insulation Layer Coverboard Roof Cover (Note 14) MDP (psf) Type Attach Type Attach Base Ply Cap LWC-12 Concrete Min. 200 psi, min. 2-inch Celcore, Elastizell or Celcore Min. 1.0-inch ISO 95+ GL, H-Shield, H-Shield CG, ENRGY 3 or min. 1.3-inch ACFoam III, Min. 1.5-inch Multi-Max FA3 or Ultra-Max CR-20 Min. 0.5-inch Structodek High Density Fiberboard or DuraBoard (homogeneous) or min. 1.5-inch FescoBoard (laminated) CR-20 BP-AA or SBS-AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -180.0 LWC-13 Concrete Min. 200 psi, min. 2-inch Celcore, Elastizell or Celcore Min. 1.0-inch ISO 95+ GL, H-Shield, H-Shield CG, ENRGY 3 or min. 1.3-inch ACFoam III, Min. 1.5-inch Multi-Max FA3 or Ultra-Max CR-20 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board or Dens Deck or Dens Deck Prime CR-20 BP-AA, SBS-AA, SBS-TA or APP-TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -180.0 COLD APPLIED SYSTEMS: LWC-14 Min. 22 ga. steel at max 5 ft spans or structural concrete Min. 350 psi, min 2-inch Range II Elastizell Lightweight Insulating Concrete with Zell Fibers. Min. 1.5-inch H-Shield CG OB500, 6-inch o.c. (Optional) Additional layers of base insulation OB500, 6-inch o.c. BP-CA3 or SBS-CA3 (Optional) BP-CA3 or SBS-CA3 SBS-CA3 -60.0 LWC-15 Min. 22 ga. steel at max 5 ft spans or structural concrete Min. 350 psi, min 2-inch Range II Elastizell Lightweight Insulating Concrete with Zell Fibers. When walkable, attach LWC with Flintfast #14 and Flintfast ϯ͟ RoƵnd Plates at 1 per 8 ft2 through to the structural deck. Min. 1.5-inch H-Shield CG OB500, 6-inch o.c. (Optional) Additional layers of base insulation OB500, 6-inch o.c. BP-CA3 or SBS-CA3 (Optional) BP-CA3 or SBS-CA3 SBS-CA3 -67.5 Exterior Research and Design, LLC. d/b/a Trinity|ERD Evaluation Report 3520.03.04-R20 for FL2533-R19 Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 20: 09/14/2017 Prepared by: Robert Nieminen, PE-59166 CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 651-5847 Appendix 1, Page 40 of 57 TABLE 4B: LIGHTWEIGHT CONCRETE DECKS – NEW CONSTRUCTION or REROOF (Tear-Off) SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) LWC (Note 13) Anchor Sheet Insulation Roof Cover (Note 14) MDP (psf) Type Fasteners Attach Base Top Attach Base Ply Cap LWC-16 Min. 22 ga. steel or structural concrete deck. Minimum 350 psi, minimum 2-inch Elastizell cellular LWIC Yosemite Venting Base ES FM-90 Base Ply Fasteners 7-inch o.c. at the 4-inch side lap and 7-inch o.c. at two, equally spaced, staggered rows in the center of the sheet Min. 1.5-inch ACFoam II (Optional) Additional layers base insulation Hot asphalt BP-AA3, 18-inch grid (Optional) BP-AA, SBS-AA SBS-AA -37.5* LWC-17 Min. 22 ga. steel or structural concrete deck. Minimum 350 psi, minimum 2-inch Approved or existing cellular LWIC Note: To qualify the LWIC under this assembly, the subject fastener shall achieve an average withdrawal of 88 lbf when tested per TAS 105 or ANSI/SPRI FX-1. Yosemite Venting Base ES Twin-Loc Nails 9-inch o.c. at the 4-inch side lap and 9-inch o.c. at two, equally spaced, staggered rows in the center of the sheet Min. 1.5-inch ACFoam II (Optional) Additional layers base insulation Hot asphalt BP-AA4, 18-inch o.c. (Optional) BP-AA, SBS-AA SBS-AA -60.0 Exterior Research and Design, LLC. d/b/a Trinity|ERD Evaluation Report 3520.03.04-R20 for FL2533-R19 Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 20: 09/14/2017 Prepared by: Robert Nieminen, PE-59166 CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 651-5847 Appendix 1, Page 41 of 57 TABLE 4C: LIGHTWEIGHT CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE E: MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Lightweight Concrete (Note 13) Base Sheet Roof Cover (Note 14) MDP (psf) Type Fasteners Attach Ply Cap SELF-ADHERING SYSTEMS: LWC-18 Min. 22 ga. steel at max 5 ft spans or structural concrete Min. 300 psi, min. 2-inch Approved cellular lightweight insulating concrete. Note: To qualify the LWIC under this assembly, a 1.8-inch Trufast Twin Loc-Nail Assembled Fastener shall achieve an average withdrawal of 73 lbf when tested per TAS 105 or ANSI/SPRI FX-1 Flintlastic SA NailBase Trufast Twin Loc-Nail Assembled Fastener ;min͘ ϭ͘ϴ͟Ϳ 7-inch o.c. at the min. 2-inch lap and 7-inch o.c. in two (2), equally spaced, staggered center rows; Stress plates shall be primed with FlintPrime (ASTM D41) primer or FlintPrime SA SBS-SA SBS-SA -60.0 LWC-19 Min. 22 ga. steel at max 5 ft spans or structural concrete Min. 300 psi, min. 2-inch Approved cellular lightweight insulating concrete. Note: To qualify the LWIC under this assembly, a 1.8-inch Trufast Twin Loc-Nail Assembled Fastener shall achieve an average withdrawal of 93 lbf when tested per TAS 105 or ANSI/SPRI FX-1 Flintlastic SA NailBase Trufast Twin Loc-Nail Assembled Fastener ;min͘ ϭ͘ϴ͟Ϳ 9-inch o.c. at the min. 2-inch lap and 9-inch o.c. in two (2), equally spaced, staggered center rows; Stress plates shall be primed with FlintPrime (ASTM D41) primer or FlintPrime SA SBS-SA SBS-SA -60.0 HYBRID SYSTEMS: LWC-20 Min. 26 ga. steel at max 5 ft spans or structural concrete Min. 200 psi, min 2-inch Range II Elastizell Lightweight Insulating Concrete. Glasbase; Flexiglas Base; Flintlastic Base 20; All Weather / Empire Base or Poly SMS Base Trufast FM-90 Base Sheet Fasteners or Trufast Twin Loc-Nail Assembled Fasteners (1.8 inch) 7½-inch o.c. at the 4-inch lap and 7½-inch o.c. in two (2), equally spaced, staggered center rows SBS-SA-H SBS-AA, SBS-TA or APP-TA -30.0 LWC-21 Min. 22 ga. steel at max 5 ft spans or structural concrete Min. 200 psi, min 2-inch Range II Elastizell Lightweight Insulating Concrete. Glasbase; Flexiglas Base; Flintlastic Base 20; All Weather / Empire Base or Poly SMS Base Trufast FM-90 Base Sheet Fasteners or Trufast Twin Loc-Nail Assembled Fasteners (1.8 inch) 7-inch o.c. at the 4-inch lap and 7-inch o.c. in two (2), equally spaced, staggered center rows SBS-SA-H SBS-AA, SBS-TA or APP-TA -45.0 LWC-22 Min. 22 ga. steel at max 5 ft spans or structural concrete Min. 300 psi, min. 2-inch Approved cellular lightweight insulating concrete. Note: To qualify the LWIC under this assembly, a 1.8-inch Trufast Twin Loc-Nail Assembled Fastener shall achieve an average withdrawal of 88 lbf when tested per TAS 105 or ANSI/SPRI FX-1 Glasbase; Flexiglas Base; Flintlastic Base 20; All Weather / Empire Base Trufast Twin Loc-Nail Assembled Fastener ;min͘ ϭ͘ϴ͟Ϳ 9-inch o.c. at the 4-inch lap and 9-inch o.c. in two (2), equally spaced, staggered center rows SBS-SA-H SBS-AA, SBS-TA or APP-TA -60.0 LWC-23 Min. 22 ga. steel at max 5 ft spans or structural concrete Min. 350 psi, min. 3-inch Approved cellular lightweight insulating concrete. Note: To qualify the LWIC under this assembly, a 1.8-inch Trufast Twin Loc-Nail Assembled Fastener shall achieve an average withdrawal of 97 lbf when tested per TAS 105 or ANSI/SPRI FX-1 Flexiglas Base; Flintlastic Base 20 or Poly SMS Base Trufast FM-90 Base Sheet Fasteners 7-inch o.c. at the 4-inch lap and 10-inch o.c. in two (2), equally spaced, staggered center rows SBS-SA-H SBS-AA, SBS-TA or APP-TA -67.5 Exterior Research and Design, LLC. d/b/a Trinity|ERD Evaluation Report 3520.03.04-R20 for FL2533-R19 Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 20: 09/14/2017 Prepared by: Robert Nieminen, PE-59166 CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 651-5847 Appendix 1, Page 42 of 57 TABLE 4C: LIGHTWEIGHT CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE E: MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Lightweight Concrete (Note 13) Base Sheet Roof Cover (Note 14) MDP (psf) Type Fasteners Attach Ply Cap LWC-24 Min. 22 ga. steel at max 5 ft spans or structural concrete Min. 300 psi, min. 2-inch Approved cellular lightweight insulating concrete. Note: To qualify the LWIC under this assembly, a 1.8-inch Trufast Twin Loc-Nail Assembled Fastener shall achieve an average withdrawal of 110 lbf when tested per TAS 105 or ANSI/SPRI FX-1 Poly SMS Base; Ultra Poly SMS Base Trufast Twin Loc-Nail Assembled Fastener ;min͘ ϭ͘ϴ͟Ϳ 9-inch o.c. at the 4-inch lap and 9-inch o.c. in two (2), equally spaced, staggered center rows SBS-SA-H SBS-AA, SBS-TA or APP-TA -75.0 CONVENTIONAL SYSTEMS: LWC-25 Min. 26 ga. steel at max 5 ft spans or structural concrete Min. 200 psi, min 2-inch Range II Elastizell Lightweight Insulating Concrete. Glasbase; Flexiglas Base; Flintlastic Base 20; All Weather / Empire Base; Poly SMS Base; Yosemite Trufast FM-90 Base Sheet Fasteners or Trufast Twin Loc-Nail Assembled Fasteners (1.8 inch) 7½-inch o.c. at the 4-inch lap and 7½-inch o.c. in two (2), equally spaced, staggered center rows (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -30.0 LWC-26 Min. 26 ga. steel at max 5 ft spans or structural concrete Min. 200 psi, min 2-inch Range II Elastizell Lightweight Insulating Concrete. Flintlastic APP Base T Trufast FM-90 Base Sheet Fasteners 7½-inch o.c. at the 4-inch lap and 7½-inch o.c. in two (2), equally spaced, staggered center rows (Optional) APP-TA APP-TA -30.0 LWC-27 Min. 22 ga. steel at max 5 ft spans or structural concrete Min. 200 psi, min 2-inch Range II Elastizell Lightweight Insulating Concrete. Glasbase; Flexiglas Base; Flintlastic Base 20; All Weather / Empire Base; Poly SMS Base; Yosemite Trufast FM-90 Base Sheet Fasteners or Trufast Twin Loc-Nail Assembled Fasteners (1.8 inch) 7-inch o.c. at the 4-inch lap and 7-inch o.c. in two (2), equally spaced, staggered center rows (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -45.0 LWC-28 Min. 22 ga. steel at max 5 ft spans or structural concrete Min. 200 psi, min 2-inch Range II Elastizell Lightweight Insulating Concrete. Flintlastic APP Base T Trufast FM-90 Base Sheet Fasteners 7-inch o.c. at the 4-inch lap and 7-inch o.c. in two (2), equally spaced, staggered center rows (Optional) APP-TA APP-TA -45.0 LWC-29 Min. 22 ga. steel at max 5 ft spans or structural concrete Min. 250 psi, min 2-inch Mearlcrete. Glasbase; Flexiglas Base; Flintlastic Base 20; All Weather / Empire Base; Poly SMS Base; Yosemite OMG CR Base Ply Fasteners (1.7) 7-inch o.c. at the 4-inch lap and 7-inch o.c. in two (2), equally spaced, staggered center rows (Optional) BP-AA or SBS-AA SBS-AA, SBS-TA or APP-TA -45.0 LWC-30 Min. 22 ga. steel at max 5 ft spans or structural concrete Min. 250 psi, min 2-inch Mearlcrete. Poly SMS Base OMG CR Base Ply Fasteners (1.7) 7-inch o.c. at the 4-inch lap and 7-inch o.c. in two (2), equally spaced, staggered center rows (Optional) BP-AA or SBS-AA SBS-AA, SBS-TA or APP-TA -52.5 Exterior Research and Design, LLC. d/b/a Trinity|ERD Evaluation Report 3520.03.04-R20 for FL2533-R19 Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 20: 09/14/2017 Prepared by: Robert Nieminen, PE-59166 CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 651-5847 Appendix 1, Page 43 of 57 TABLE 4C: LIGHTWEIGHT CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE E: MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Lightweight Concrete (Note 13) Base Sheet Roof Cover (Note 14) MDP (psf) Type Fasteners Attach Ply Cap LWC-31 Min. 22 ga. steel at max 5 ft spans or structural concrete Min. 300 psi, min 2-inch Mearlcrete. Glasbase; Flexiglas Base; Flintlastic Base 20; All Weather / Empire Base; Poly SMS Base; Yosemite OMG CR Base Ply Fasteners (1.7) 7-inch o.c. at the 4-inch lap and 7-inch o.c. in two (2), equally spaced, staggered center rows (Optional) BP-AA or SBS-AA SBS-AA, SBS-TA or APP-TA -52.5 LWC-32 Min. 22 ga. steel at max 5 ft spans or structural concrete Concrecel Bonding Agent on deck; Min. 300 psi, min 2¼-inch Concrecel Concrete. Glasbase; Flexiglas Base; Flintlastic Base 20; All Weather / Empire Base; Poly SMS Base; Yosemite OMG CR Base Ply Fasteners (1.7) 7-inch o.c. at the 3-inch lap and 7-inch o.c. in two (2), equally spaced, staggered center rows (Optional) BP-AA or SBS-AA SBS-AA, SBS-TA or APP-TA -52.5 LWC-33 Min. 22 ga. steel at max 5 ft spans or structural concrete Min. 300 psi, min. 2-inch Approved cellular lightweight insulating concrete. Note: To qualify the LWIC under this assembly, a 1.8-inch Trufast Twin Loc-Nail Assembled Fastener shall achieve an average withdrawal of 88 lbf when tested per TAS 105 or ANSI/SPRI FX-1 Glasbase; Flexiglas Base; Flintlastic Base 20; All Weather / Empire Base; Yosemite Trufast Twin Loc-Nail Assembled Fastener ;min͘ ϭ͘ϴ͟Ϳ 9-inch o.c. at the 4-inch lap and 9-inch o.c. in two (2), equally spaced, staggered center rows (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -60.0 LWC-34 Min. 22 ga., type B steel at max. 5 ft spans structural concrete Min. 300 psi, min 2-inch Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture. After setting to support foot traffic, Celcore PVA Curing Compound is applied. All Weather / Empire Base; Flintlastic Base 20; Poly SMS Base Trufast FM-90 Base Sheet Fasteners 9-inch o.c. at 4-inch laps and 12-inch o.c. in two (2), equally spaced, staggered center rows (Optional) BP-AA, SBS-AA or SBS-TA-F SBS-AA or SBS-TA-F -60.0 LWC-35 Min. 22 ga. steel at max 5 ft spans or structural concrete Min. 300 psi, min. 2-inch Approved cellular lightweight insulating concrete. Note: To qualify the LWIC under this assembly, a 1.8-inch Trufast Twin Loc-Nail Assembled Fastener shall achieve an average withdrawal of 77 lbf when tested per TAS 105 or ANSI/SPRI FX-1 Glasbase; Flexiglas Base; Flintlastic Base 20; All Weather / Empire Base; Yosemite Trufast Twin Loc-Nail Assembled Fastener ;min͘ ϭ͘ϴ͟Ϳ 7-inch o.c. at the 4-inch lap and 7-inch o.c. in two (2), equally spaced, staggered center rows BP-AA or SBS-AA SBS-AA, SBS-TA or APP-TA -67.5 LWC-36 Min. 22 ga. steel at max 5 ft spans or structural concrete Min. 350 psi, min. 3-inch Approved cellular lightweight insulating concrete. Note: To qualify the LWIC under this assembly, a 1.8-inch Trufast Twin Loc-Nail Assembled Fastener shall achieve an average withdrawal of 97 lbf when tested per TAS 105 or ANSI/SPRI FX-1 Flexiglas Base; Flintlastic Base 20; Poly SMS Base; Yosemite Trufast FM-90 Base Sheet Fasteners 7-inch o.c. at the 4-inch lap and 10-inch o.c. in two (2), equally spaced, staggered center rows BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -67.5 Exterior Research and Design, LLC. d/b/a Trinity|ERD Evaluation Report 3520.03.04-R20 for FL2533-R19 Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 20: 09/14/2017 Prepared by: Robert Nieminen, PE-59166 CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 651-5847 Appendix 1, Page 44 of 57 TABLE 4C: LIGHTWEIGHT CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE E: MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Lightweight Concrete (Note 13) Base Sheet Roof Cover (Note 14) MDP (psf) Type Fasteners Attach Ply Cap LWC-37 Min. 22 ga. steel at max 5 ft spans or structural concrete Min. 300 psi, min. 2-inch Approved cellular lightweight insulating concrete. Note: To qualify the LWIC under this assembly, a 1.8-inch Trufast Twin Loc-Nail Assembled Fastener shall achieve an average withdrawal of 110 lbf when tested per TAS 105 or ANSI/SPRI FX-1 Poly SMS Base; Ultra Poly SMS Base Trufast Twin Loc-Nail Assembled Fastener ;min͘ ϭ͘ϴ͟Ϳ 9-inch o.c. at the 4-inch lap and 9-inch o.c. in two (2), equally spaced, staggered center rows BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -75.0 LWC-38 Min. 22 ga. steel at max 5 ft spans or structural concrete Min. 300 psi, min 2-inch Celcore Cellular Concrete. After setting to support foot traffic, Celcore PVA Curing Compound is applied. Glasbase; Flexiglas Base; Flintlastic Base 20; All Weather / Empire Base; Poly SMS Base; Yosemite Trufast FM-90 Base Sheet Fasteners 7-inch o.c. at the 3-inch lap and 7-inch o.c. in two (2), equally spaced, staggered center rows BP-AA or SBS-AA SBS-AA, SBS-TA or APP-TA -75.0 COLD APPLIED SYSTEMS: LWC-39 Min. 22 ga. steel at max 5 ft spans or structural concrete Min. 350 psi, min 2-inch Range II Elastizell Lightweight Insulating Concrete with Zell Fibers. Flintlastic Base 20; Poly SMS Base Trufast FM-90 Base Sheet Fasteners 7-inch o.c. at the 4-inch lap and 7-inch o.c. in two (2), equally spaced, staggered center rows (Optional) BP-CA2 or SBS-CA2 SBS-CA2 -45.0 LWC-40 Min. 22 ga. steel at max 5 ft spans Min. 350 psi, min 2-inch Range II Elastizell Lightweight Insulating Concrete with Zell Fibers. Glasbase; Flexiglas Base; Poly SMS Base Trufast FM-90 Base Sheet Fasteners 7-inch o.c. at the 4-inch lap and 7-inch o.c. in two (2), equally spaced, staggered center rows (Optional) BP-CA3 or SBS-CA3 SBS-CA3 -52.5 LWC-41 Structural concrete Min. 350 psi, min 2-inch Range II Elastizell Lightweight Insulating Concrete with Zell Fibers. Glasbase; Flexiglas Base; Poly SMS Base Trufast FM-90 Base Sheet Fasteners 7-inch o.c. at the 4-inch lap and 7-inch o.c. in two (2), equally spaced, staggered center rows (Optional) BP-CA3 or SBS-CA3 SBS-CA3 -60.0 Exterior Research and Design, LLC. d/b/a Trinity|ERD Evaluation Report 3520.03.04-R20 for FL2533-R19 Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 20: 09/14/2017 Prepared by: Robert Nieminen, PE-59166 CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 651-5847 Appendix 1, Page 45 of 57 TABLE 5A: CEMENTITIOUS WOOD FIBER DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer Top Insulation Layer Roof Cover (Note 14) MDP (psf) Type Attach Type Attach Base Ply Cap SELF-ADHERING SYSTEMS: CWF-1. Tectum Min. 1.5-inch FlintBoard ISO, ACFoam II, ENRGY 3 or Multi-Max FA3 OB500 Min. 0.25-inch Dens Deck primed with FlintPrime or FlintPrime SA; or SECUROCK Gypsum-Fiber Roof Board OB500 SBS-SA (Optional) SBS-SA SBS-SA -45.0* CWF-2. Tectum Min. 1.0-inch ISO 95+ GL, H-Shield, H-Shield CG, ENRGY 3 or min. 1.3-inch ACFoam III, Min. 1.5-inch Multi-Max FA3 or Ultra-Max CR-20 Min. 0.25-inch Dens Deck primed with FlintPrime or FlintPrime SA; or SECUROCK Gypsum-Fiber Roof Board CR-20 SBS-SA (Optional) SBS-SA SBS-SA -52.5 CONVENTIONAL SYSTEMS: CWF-3. Tectum Min. 1.5-inch FlintBoard ISO, ACFoam II, ENRGY 3 or Multi-Max FA3 OB500 Min. 0.5-inch Structodek High Density Fiberboard OB500 BP-AA or SBS-AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -45.0* CWF-4. Tectum Min. 1.5-inch FlintBoard ISO, ACFoam II, ENRGY 3 or Multi-Max FA3 OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board or Dens Deck or Dens Deck Prime OB500 BP-AA, SBS-AA, SBS-TA or APP-TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -45.0* CWF-5. Tectum Min. 1.0-inch ISO 95+ GL, H-Shield, H-Shield CG, ENRGY 3 or min. 1.3-inch ACFoam III, Min. 1.5-inch Multi-Max FA3 or Ultra- CR-20 Min. 0.5-inch Structodek High Density Fiberboard or DuraBoard (homogeneous) or min. 1.5-inch FescoBoard (laminated) CR-20 BP-AA or SBS-AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -52.5 CWF-6. Tectum Min. 1.0-inch ISO 95+ GL, H-Shield, H-Shield CG, ENRGY 3 or min. 1.3-inch ACFoam III, Min. 1.5-inch Multi-Max FA3 or Ultra-Max CR-20 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board or Dens Deck or Dens Deck Prime CR-20 BP-AA, SBS-AA, SBS-TA or APP-TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -52.5 Exterior Research and Design, LLC. d/b/a Trinity|ERD Evaluation Report 3520.03.04-R20 for FL2533-R19 Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 20: 09/14/2017 Prepared by: Robert Nieminen, PE-59166 CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 651-5847 Appendix 1, Page 46 of 57 TABLE 5B: CEMENTITIOUS WOOF FIBER DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 14) MDP (psf) Type Fasteners Attach Type Attach Type Attach Base Ply Cap HYBRID SYSTEMS: CWF-7. Tectum Glasbase; Flexiglas Base; Flintlastic Base 20; All Weather / Empire Base; Yosemite Trufast Twin Loc-Nail Assembled Fastener ;min͘ ϭ͘ϴ͟Ϳ 7-inch o.c. at the 4-inch lap and 7-inch o.c. in two (2), equally spaced, staggered center rows Min. 1.5-inch ACFoam II, FlintBoard ISO, ENRGY 3 or Multi-Max FA3 HA None N/A SBS-SA-H (Optional) SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -60.0 CONVENTIONAL SYSTEMS: CWF-8. Tectum Glasbase; Flexiglas Base; Flintlastic Base 20; All Weather / Empire Base; Yosemite Trufast Twin Loc-Nail Assembled Fastener ;min͘ ϭ͘ϴ͟Ϳ 7-inch o.c. at the 4-inch lap and 7-inch o.c. in two (2), equally spaced, staggered center rows Min. 1.5-inch ACFoam II, FlintBoard ISO, ENRGY 3 or Multi-Max FA3 HA Min. 0.75-inch FescoBoard (homogeneous) or min. 0.5-inch Structodek High Density Fiberboard HA BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-AA, SBS-TA or APP-TA -60.0 TABLE 5C: CEMENTITIOUS WOOD FIBER DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE C: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer(s) Top Insulation Layer Roof Cover (Note 14) MDP (psf) Type Fasteners Attach Base Ply Cap CWF-9. Tectum (Optional) One or more layers, any combination, loose laid Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation OMG PolLJmer GLJpTec ǁith ϯ͟ GypTec Plate 1 per 2 ft2 BP-AA or SBS-AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -45.0* CWF-10. Tectum (Optional) One or more layers, any combination, loose laid Min. 0.25-inch Dens Deck or Dens Deck Prime OMG PolLJmer GLJpTec ǁith ϯ͟ GypTec Plate 1 per 1.78 ft2 BP-AA, SBS-AA, SBS-TA or APP-TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -45.0* CWF-11. Tectum (Optional) One or more layers, any combination, loose laid Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation Trufast Twin Loc-Nail Assembled Fasteners (minimum 1-inch embedment into deck) 1 per 2 ft2 BP-AA or SBS-AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -45.0* CWF-12. Tectum (Optional) One or more layers, any combination, loose laid Min. 0.25-inch Dens Deck or Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board Trufast Twin Loc-Nail Assembled Fasteners (minimum 1-inch embedment into deck) 1 per 2 ft2 BP-AA, SBS-AA, SBS-TA or APP-TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -45.0* Exterior Research and Design, LLC. d/b/a Trinity|ERD Evaluation Report 3520.03.04-R20 for FL2533-R19 Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 20: 09/14/2017 Prepared by: Robert Nieminen, PE-59166 CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 651-5847 Appendix 1, Page 47 of 57 TABLE 5D: CEMENTITOUS WOOD FIBER DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE E: MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Base Sheet Roof Cover (Note 14) MDP (psf) Base Fasteners Attach Ply Cap SELF-ADHERING SYSTEMS: CWF-13. Tectum Flintlastic SA NailBase Trufast Twin Loc-Nail Assembled Fastener (min. ϭ͘ϴ͟Ϳ 7-inch o.c. at the 4-inch lap and 7-inch o.c. in two (2), equally spaced, staggered center rows SBS-SA SBS-SA -60.0 CONVENTIONAL SYSTEMS: CWF-14. Tectum All Weather / Empire Base; Yosemite Trufast Insuldeck Loc-Nail Base Sheet Fastener 9-inch o.c. at the 4-inch lap and 12-inch o.c. in two (2), equally spaced, staggered center rows BP-AA or SBS-AA SBS-AA -30.0* CWF-15. Tectum All Weather / Empire Base; Yosemite Trufast Insuldeck Loc-Nail Base Sheet Fastener 7½-inch o.c. at the 4-inch lap and 7½-inch o.c. in two (2), equally spaced, staggered center rows BP-AA or SBS-AA SBS-AA -45.0* CWF-16. Tectum Glasbase; Flexiglas Base; All Weather / Empire Base; Yosemite Simplex Turbo Tube-Lok 9-inch o.c. at the 4-inch lap and 12-inch o.c. in two (2), equally spaced, staggered center rows SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -45.0* CWF-17. Tectum Glasbase; Flexiglas Base; Flintlastic Base 20 or All Weather / Empire Base; Yosemite Trufast Twin Loc-Nail Assembled Fastener (min. ϭ͘ϴ͟Ϳ 7-inch o.c. at the 4-inch lap and 7-inch o.c. in two (2), equally spaced, staggered center rows BP-AA or SBS-AA SBS-AA, SBS-TA or APP-TA -67.5 Exterior Research and Design, LLC. d/b/a Trinity|ERD Evaluation Report 3520.03.04-R20 for FL2533-R19 Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 20: 09/14/2017 Prepared by: Robert Nieminen, PE-59166 CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 651-5847 Appendix 1, Page 48 of 57 TABLE 6A: GYPSUM DECKS – REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER System No. Deck Base Insulation Layer Top Insulation Layer Roof Cover (Note 14) MDP (psf) Type Attach Type Attach Base Ply Cap SELF-ADHERING SYSTEMS: G-1. Existing sound gypsum or gypsum plank Min. 1.5-inch ACFoam II, FlintBoard, ENRGY 3 or H-Shield M-OSFA Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board M-OSFA SBS-SA (Optional) SBS-SA SBS-SA -172.5 G-2. Existing sound gypsum or gypsum plank Min. 1.5-inch ACFoam II, FlintBoard, ENRGY 3 or Multi-Max FA M-OSFA Min. 0.25-inch Dens Deck primed with FlintPrime or FlintPrime SA M-OSFA SBS-SA (Optional) SBS-SA SBS-SA -192.5 G-3. Existing sound gypsum or gypsum plank Min. 1.5-inch ACFoam II, FlintBoard ISO or ENRGY 3 OB500 Min. 0.25-inch Dens Deck primed with FlintPrime or FlintPrime SA or SECUROCK Gypsum-Fiber Roof Board OB500 SBS-SA (Optional) SBS-SA SBS-SA -135.0 G-4. Existing sound gypsum or gypsum plank Min. 1.0-inch ISO 95+ GL, H-Shield, H-Shield CG, ENRGY 3 or min. 1.3-inch ACFoam III, Min. 1.5-inch Multi-Max FA3 or Ultra-Max CR-20 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board CR-20 SBS-SA (Optional) SBS-SA SBS-SA -172.5 G-5. Existing sound gypsum or gypsum plank Min. 1.0-inch ISO 95+ GL, H-Shield, H-Shield CG, ENRGY 3 or min. 1.3-inch ACFoam III, Min. 1.5-inch Multi-Max FA3 or Ultra-Max CR-20 Min. 0.25-inch Dens Deck primed with FlintPrime or FlintPrime SA CR-20 SBS-SA (Optional) SBS-SA SBS-SA -192.5 CONVENTIONAL SYSTEMS: G-6. Existing sound gypsum or gypsum plank Min. 1.5-inch ACFoam II, FlintBoard ISO, ENRGY 3 or H-Shield M-OSFA Min. 0.5-inch Structodek High Density Fiberboard M-OSFA BP-AA or SBS-AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -127.5 G-7. Existing sound gypsum or gypsum plank Min. 1.5-inch ACFoam II, FlintBoard ISO, ENRGY 3 or H-Shield M-OSFA Min. 0.25-inch Dens Deck M-OSFA BP-AA or SBS-AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -232.5 G-8. Existing sound gypsum or gypsum plank Min. 2-inch ACFoam II, FlintBoard ISO, ENRGY 3 or H-Shield M-OSFA Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board M-OSFA BP-AA or SBS-AA, SBS-TA or APP-TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -202.5 G-9. Existing sound gypsum or gypsum plank Min. 1.5-inch ACFoam II, FlintBoard ISO, ENRGY 3 or H-Shield OB500 Min. 0.5-inch Structodek High Density Fiberboard OB500 BP-AA or SBS-AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -120.0 G-10. Existing sound gypsum or gypsum plank Min. 1.5-inch ACFoam II, FlintBoard ISO, ENRGY 3 or H-Shield OB500 Min. 0.25-inch Dens Deck, Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 BP-AA, SBS-AA, SBS-TA or APP-TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -135.0 G-11. Existing sound gypsum or gypsum plank Min. 1.0-inch ISO 95+ GL, H-Shield, H-Shield CG, ENRGY 3 or min. 1.3-inch ACFoam III, Min. 1.5-inch Multi-Max FA3 or Ultra-Max CR-20 Min. 0.25-inch Dens Deck or Dens Deck Prime CR-20 SBS-TA (Optional) SBS-TA SBS-TA -180.0 Exterior Research and Design, LLC. d/b/a Trinity|ERD Evaluation Report 3520.03.04-R20 for FL2533-R19 Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 20: 09/14/2017 Prepared by: Robert Nieminen, PE-59166 CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 651-5847 Appendix 1, Page 49 of 57 TABLE 6A: GYPSUM DECKS – REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER System No. Deck Base Insulation Layer Top Insulation Layer Roof Cover (Note 14) MDP (psf) Type Attach Type Attach Base Ply Cap G-12. Existing sound gypsum or gypsum plank Min. 1.0-inch ISO 95+ GL, H-Shield, H-Shield CG, ENRGY 3 or min. 1.3-inch ACFoam III, Min. 1.5-inch Multi-Max FA3 or Ultra-Max CR-20 Min. 0.5-inch Structodek High Density Fiberboard or DuraBoard (homogeneous) or min. 1.5-inch FescoBoard (laminated) CR-20 BP-AA or SBS-AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -180.0 G-13. Existing sound gypsum or gypsum plank Min. 1.0-inch ISO 95+ GL, H-Shield, H-Shield CG, ENRGY 3 or min. 1.3-inch ACFoam III, Min. 1.5-inch Multi-Max FA3 or Ultra-Max CR-20 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board CR-20 BP-AA or SBS-AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -225.0 G-14. Existing sound gypsum or gypsum plank Min. 1.0-inch ISO 95+ GL, H-Shield, H-Shield CG, ENRGY 3 or min. 1.3-inch ACFoam III, Min. 1.5-inch Multi-Max FA3 or Ultra-Max CR-20 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board CR-20 SBS-TA or APP-TA (Optional) SBS-TA or APP-TA SBS-TA or APP-TA -232.5 G-15. Existing sound gypsum or gypsum plank Min. 1.0-inch ISO 95+ GL, H-Shield, H-Shield CG, ENRGY 3 or min. 1.3-inch ACFoam III, Min. 1.5-inch Multi-Max FA3 or Ultra-Max CR-20 Min. 0.25-inch Dens Deck CR-20 BP-AA or SBS-AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -240.0 Exterior Research and Design, LLC. d/b/a Trinity|ERD Evaluation Report 3520.03.04-R20 for FL2533-R19 Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 20: 09/14/2017 Prepared by: Robert Nieminen, PE-59166 CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 651-5847 Appendix 1, Page 50 of 57 TABLE 6B: GYPSUM DECKS – REROOF (TEAR-OFF) SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 14) MDP (psf) Type Fasteners Attach Type Attach Type Attach Base Ply Cap HYBRID SYSTEMS: G-16. Existing sound gypsum or gypsum plank Glasbase; Flexiglas Base; Flintlastic Base 20; All Weather / Empire Base; Yosemite Trufast Twin Loc-Nail Assembled Fastener ;min͘ ϭ͘ϴ͟Ϳ 7-inch o.c. at the 4-inch lap and 7-inch o.c. in two (2), equally spaced, staggered center rows Min. 1.5-inch ACFoam II, FlintBoard ISO, ENRGY 3 or Multi-Max FA3 HA None N/A SBS-SA-H (Optional) SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -60.0 CONVENTIONAL SYSTEMS: G-17. Existing sound gypsum or gypsum plank All Weather / Empire Base; Yosemite Trufast FM-75 or FM-90 Base Sheet Fastener 9-inch o.c. at the 4-inch lap and 18-inch o.c. in two (2), equally spaced, staggered center rows (Optional) Min. 1.5-inch ACFoam II, FlintBoard ISO, ENRGY 3 or Multi-Max FA3 HA Min. 0.75-inch FescoBoard (homogeneous) or min. 0.5-inch Structodek High Density Fiberboard HA BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-AA, SBS-TA or APP-TA -45.0* G-18. Existing sound gypsum or gypsum plank Glasbase; Flexiglas Base; Flintlastic Base 20; All Weather / Empire Base; Yosemite Trufast Twin Loc-Nail Assembled Fastener ;min͘ ϭ͘ϴ͟Ϳ 7-inch o.c. at the 4-inch lap and 7-inch o.c. in two (2), equally spaced, staggered center rows Min. 1.5-inch ACFoam II, FlintBoard ISO, ENRGY 3 or Multi-Max FA3 HA Min. 0.75-inch FescoBoard (homogeneous) or min. 0.5-inch Structodek High Density Fiberboard HA BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-AA, SBS-TA or APP-TA -60.0 Exterior Research and Design, LLC. d/b/a Trinity|ERD Evaluation Report 3520.03.04-R20 for FL2533-R19 Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 20: 09/14/2017 Prepared by: Robert Nieminen, PE-59166 CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 651-5847 Appendix 1, Page 51 of 57 TABLE 6C: GYPSUM DECKS – REROOF (TEAR-OFF) SYSTEM TYPE C: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer(s) Top Insulation Layer Roof Cover (Note 14) MDP (psf) Type Fasteners Attach Base Ply Cap G-19. Existing sound gypsum or gypsum plank (Optional) One or more layers, any combination, loose laid Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation OMG PolLJmer GLJpTec ǁith ϯ͟ GypTec Plate 1 per 2 ft2 BP-AA or SBS-AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -45.0* G-20. Existing sound gypsum or gypsum plank (Optional) One or more layers, any combination, loose laid Min. 0.25-inch Dens Deck or Dens Deck Prime OMG PolLJmer GLJpTec ǁith ϯ͟ GypTec Plate 1 per 1.78 ft2 BP-AA, SBS-AA, SBS-TA or APP-TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -45.0* G-21. Existing sound gypsum or gypsum plank (Optional) One or more layers, any combination, loose laid Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation Trufast Twin Loc-Nail Assembled Fasteners (minimum 1-inch embedment into deck) 1 per 2 ft2 BP-AA or SBS-AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -45.0* G-22. Existing sound gypsum or gypsum plank (Optional) One or more layers, any combination, loose laid Min. 0.25-inch Dens Deck or Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board Trufast Twin Loc-Nail Assembled Fasteners (minimum 1-inch embedment into deck) 1 per 2 ft2 BP-AA, SBS-AA, SBS-TA or APP-TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -45.0* TABLE 6D: GYPSUM DECKS – REROOF (TEAR-OFF) SYSTEM TYPE E: MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Base Sheet Roof Cover (Note 14) MDP (psf) Base Fasteners Attach Ply Cap SELF-ADHERING SYSTEMS: G-23. Existing sound gypsum or gypsum plank Flintlastic SA NailBase Trufast Twin Loc-Nail Assembled Fastener ;min͘ ϭ͘ϴ͟Ϳ 9-inch o.c. at the 4-inch lap and 9-inch o.c. in two (2), equally spaced, staggered center rows SBS-SA SBS-SA -60.0 CONVENTIONAL SYSTEMS: G-24. Existing sound gypsum or gypsum plank All Weather / Empire Base; Yosemite Trufast FM-75 or FM-90 Base Sheet Fastener 9-inch o.c. at the 4-inch lap and 18-inch o.c. in two (2), equally spaced, staggered center rows BP-AA or SBS-AA SBS-AA -45.0* G-25. Existing sound gypsum or gypsum plank Glasbase; Flexiglas Base; All Weather / Empire Base; Yosemite Simplex Turbo Tube-Lok 9-inch o.c. at the 4-inch lap and 12-inch o.c. in two (2), equally spaced, staggered center rows SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -45.0* G-26. Existing sound gypsum or gypsum plank Glasbase; Flexiglas Base; Flintlastic Base 20; All Weather / Empire Base; Yosemite Trufast Twin Loc-Nail Assembled Fastener ;min͘ ϭ͘ϴ͟Ϳ 9-inch o.c. at the 4-inch lap and 9-inch o.c. in two (2), equally spaced, staggered center rows BP-AA or SBS-AA SBS-AA, SBS-TA or APP-TA -67.5 Exterior Research and Design, LLC. d/b/a Trinity|ERD Evaluation Report 3520.03.04-R20 for FL2533-R19 Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 20: 09/14/2017 Prepared by: Robert Nieminen, PE-59166 CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 651-5847 Appendix 1, Page 52 of 57 TABLE 7A: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER System No. Substrate (Notes 1 & 11) Base Insulation Layer Top Insulation Layer Roof Cover (Note 14) MDP (psf) Type Attach Type Attach Base Ply Cap SELF-ADHERING SYSTEMS: R-1 Existing fully bonded BUR or modified bitumen roof cover Min. 0.25-inch Dens Deck primed with FlintPrime or FlintPrime SA; or SECUROCK Gypsum-Fiber Roof Board. HA None N/A SBS-SA (Optional) SBS-SA SBS-SA -105.0 R-2 Existing fully bonded BUR or modified bitumen roof cover Min. 1.5-inch ACFoam II, FlintBoard ISO, ENRGY 3, H-Shield or Multi-Max FA3 HA Min. 0.25-inch Dens Deck primed with FlintPrime or FlintPrime SA; or SECUROCK Gypsum-Fiber Roof Board. HA SBS-SA (Optional) SBS-SA SBS-SA -105.0 R-3 Existing fully bonded, smooth surface BUR or modified bitumen Min. 0.25-inch Dens Deck primed with FlintPrime or FlintPrime SA or SECUROCK Gypsum-Fiber Roof Board A-PD, 6-inch o.c. None N/A SBS-SA (Optional) SBS-SA SBS-SA -105.0 R-4 Existing fully bonded, mineral surface modified bitumen Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board A-PD, 6-inch o.c. None N/A SBS-SA (Optional) SBS-SA SBS-SA -172.5 R-5 Existing fully bonded, mineral surface modified bitumen Min. 0.25-inch Dens Deck primed with FlintPrime or FlintPrime SA A-PD, 6-inch o.c. None N/A SBS-SA (Optional) SBS-SA SBS-SA -180.0 R-6 Existing fully bonded, smooth surface BUR or modified bitumen Min. 1.5-inch ACFoam II, FlintBoard, ENRGY 3 or Multi-Max FA3 A-PD, 6-inch o.c. Min. 0.25-inch Dens Deck primed with FlintPrime or FlintPrime SA or SECUROCK Gypsum-Fiber Roof Board A-PD, 6-inch o.c. SBS-SA (Optional) SBS-SA SBS-SA -52.5 R-7 Existing fully bonded, mineral surface BUR or modified bitumen Min. 1.5-inch ACFoam II, FlintBoard, ENRGY 3 or Multi-Max FA3 A-PD, 6-inch o.c. Min. 0.25-inch Dens Deck primed with FlintPrime or FlintPrime SA or SECUROCK Gypsum-Fiber Roof Board A-PD, 6-inch o.c. SBS-SA (Optional) SBS-SA SBS-SA -172.5 R-8 Existing fully bonded BUR or modified bitumen roof cover Min. 1.5-inch ACFoam II, FlintBoard, ENRGY 3 or H-Shield M-OSFA Min. 0.25-inch Dens Deck primed with FlintPrime or FlintPrime SA or SECUROCK Gypsum-Fiber Roof Board M-OSFA SBS-SA (Optional) SBS-SA SBS-SA -157.5 R-9 Existing fully bonded, smooth- or granule-surface BUR or modified bitumen Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board M-PG1 None N/A SBS-SA (Optional) SBS-SA SBS-SA -172.5 R-10 Existing fully bonded, smooth- or granule-surface BUR or modified bitumen Min. 0.25-inch Dens Deck primed with FlintPrime or FlintPrime SA M-PG1 None N/A SBS-SA (Optional) SBS-SA SBS-SA -180.0 R-11 Existing fully bonded BUR or modified bitumen roof cover Min. 1.5-inch ACFoam II, FlintBoard, ENRGY 3 or H-Shield M-PG1 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board M-PG1 SBS-SA (Optional) SBS-SA SBS-SA -172.5 Exterior Research and Design, LLC. d/b/a Trinity|ERD Evaluation Report 3520.03.04-R20 for FL2533-R19 Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 20: 09/14/2017 Prepared by: Robert Nieminen, PE-59166 CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 651-5847 Appendix 1, Page 53 of 57 TABLE 7A: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER System No. Substrate (Notes 1 & 11) Base Insulation Layer Top Insulation Layer Roof Cover (Note 14) MDP (psf) Type Attach Type Attach Base Ply Cap R-12 Existing fully bonded BUR or modified bitumen roof cover Min. 1.5-inch ACFoam II, FlintBoard, ENRGY 3 or Multi-Max FA M-PG1 Min. 0.25-inch Dens Deck primed with FlintPrime or FlintPrime SA M-PG1 SBS-SA (Optional) SBS-SA SBS-SA -180.0 R-13 Existing fully bonded, smooth- or granule-surface BUR or modified bitumen Min. 0.25-inch Dens Deck primed with FlintPrime or FlintPrime SA or SECUROCK Gypsum-Fiber Roof Board OB500 None N/A SBS-SA (Optional) SBS-SA SBS-SA -120.0 R-14 Existing fully bonded BUR or modified bitumen roof cover Min. 1.5-inch ACFoam II, FlintBoard ISO or ENRGY 3 OB500 Min. 0.25-inch Dens Deck primed with FlintPrime or FlintPrime SA or SECUROCK Gypsum-Fiber Roof Board OB500 SBS-SA (Optional) SBS-SA SBS-SA -120.0 R-15 Existing fully bonded, smooth- or granule-surface BUR or modified bitumen Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board CR-20 None N/A SBS-SA (Optional) SBS-SA SBS-SA -172.5 R-16 Existing fully bonded, smooth- or granule-surface BUR or modified bitumen Min. 0.25-inch Dens Deck primed with FlintPrime or FlintPrime SA CR-20 None N/A SBS-SA (Optional) SBS-SA SBS-SA -192.5 R-17 Existing fully bonded BUR or modified bitumen roof cover Min. 1.0-inch ISO 95+ GL, H-Shield, H-Shield CG, ENRGY 3 or min. 1.3-inch ACFoam III, Min. 1.5-inch Multi-Max FA3 or Ultra-Max CR-20 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board CR-20 SBS-SA (Optional) SBS-SA SBS-SA -172.5 R-18 Existing fully bonded BUR or modified bitumen roof cover Min. 1.0-inch ISO 95+ GL, H-Shield, H-Shield CG, ENRGY 3 or min. 1.3-inch ACFoam III, Min. 1.5-inch Multi-Max FA3 or Ultra-Max CR-20 Min. 0.25-inch Dens Deck primed with FlintPrime or FlintPrime SA CR-20 SBS-SA (Optional) SBS-SA SBS-SA -192.5 HYBRID SYSTEMS: R-19 Existing fully bonded BUR or modified bitumen roof cover Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board HA None N/A SBS-SA-H (Optional) SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -105.0 R-20 Existing fully bonded, smooth surface BUR or modified bitumen Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board A-PD, 6-inch o.c. None N/A SBS-SA-H (Optional) SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -105.0 R-21 Existing fully bonded, mineral surface modified bitumen Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board A-PD, 6-inch o.c. None N/A SBS-SA-H (Optional) SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -180.0 R-22 Existing fully bonded, smooth- or granule-surface BUR or modified bitumen Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board M-PG1 None N/A SBS-SA-H (Optional) SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -180.0 R-23 Existing fully bonded, smooth- or granule-surface BUR or modified bitumen Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 None N/A SBS-SA-H (Optional) SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -120.0 Exterior Research and Design, LLC. d/b/a Trinity|ERD Evaluation Report 3520.03.04-R20 for FL2533-R19 Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 20: 09/14/2017 Prepared by: Robert Nieminen, PE-59166 CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 651-5847 Appendix 1, Page 54 of 57 TABLE 7A: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER System No. Substrate (Notes 1 & 11) Base Insulation Layer Top Insulation Layer Roof Cover (Note 14) MDP (psf) Type Attach Type Attach Base Ply Cap R-24 Existing fully bonded, smooth- or granule-surface BUR or modified bitumen Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board CR-20 None N/A SBS-SA-H (Optional) SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -195.0 CONVENTIONAL SYSTEMS: R-25 Existing fully bonded BUR or modified bitumen roof cover 0.5-inch Structodek High Density Fiberboard or min. 0.75-inch Fesco Board (homogeneous) HA None N/A BP-AA, SBS-AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -105.0 R-26 Existing fully bonded BUR or modified bitumen roof cover 0.25-inch Dens Deck, Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board HA None N/A BP-AA, SBS-AA, SBS-TA or APP-TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -105.0 R-27 Existing fully bonded BUR or modified bitumen roof cover Min. 1.5-inch ACFoam II, FlintBoard ISO, ENRGY 3, H-Shield or Multi-Max FA3 HA Min. 0.5-inch Structodek High Density Fiberboard, Min. 0.75-inch FescoBoard (homogeneous) or Min. 0.5-inch DuraBoard (homogeneous) HA BP-AA or SBS-AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -105.0 R-28 Existing fully bonded BUR or modified bitumen roof cover Min. 1.5-inch ACFoam II, FlintBoard ISO, ENRGY 3, H-Shield or Multi-Max FA3 HA Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board, Dens Deck, Dens Deck Prime HA BP-AA, SBS-AA, SBS-TA or APP-TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -105.0 R-29 Existing fully bonded, smooth surface BUR or modified bitumen Min. 0.5-inch Structodek High Density Fiberboard A-PD, 6-inch o.c. None N/A BP-AA, SBS-AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -105.0 R-30 Existing fully bonded, mineral surface modified bitumen Min. 0.5-inch Structodek High Density Fiberboard A-PD, 6-inch o.c. None N/A BP-AA, SBS-AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -180.0 R-31 Existing fully bonded, smooth surface BUR or modified bitumen Min. 0.25-inch Dens Deck, Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board A-PD, 6-inch o.c. None N/A BP-AA, SBS-AA, SBS-TA or APP-TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -105.0 R-32 Existing fully bonded, mineral surface modified bitumen Min. 0.25-inch Dens Deck, Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board A-PD, 6-inch o.c. None N/A BP-AA, SBS-AA, SBS-TA or APP-TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -180.0 R-33 Existing fully bonded, smooth surface BUR or modified bitumen Min. 1.5-inch ACFoam II, FlintBoard ISO, ENRGY 3 or H-Shield A-PD, 6-inch o.c. Min. 0.5-inch Structodek High Density Fiberboard A-PD, 6-inch o.c. BP-AA or SBS-AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -52.5 R-34 Existing fully bonded, smooth surface BUR or modified bitumen Min. 2-inch ACFoam II, FlintBoard ISO, ENRGY 3 or H-Shield A-PD, 6-inch o.c. Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board or Dens Deck A-PD, 6-inch o.c. BP-AA or SBS-AA, SBS-TA or APP-TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -52.5 Exterior Research and Design, LLC. d/b/a Trinity|ERD Evaluation Report 3520.03.04-R20 for FL2533-R19 Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 20: 09/14/2017 Prepared by: Robert Nieminen, PE-59166 CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 651-5847 Appendix 1, Page 55 of 57 TABLE 7A: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER System No. Substrate (Notes 1 & 11) Base Insulation Layer Top Insulation Layer Roof Cover (Note 14) MDP (psf) Type Attach Type Attach Base Ply Cap R-35 Existing fully bonded, mineral surface BUR or modified bitumen Min. 1.5-inch ACFoam II, FlintBoard ISO, ENRGY 3 or H-Shield A-PD, 6-inch o.c. Min. 0.5-inch Structodek High Density Fiberboard A-PD, 6-inch o.c. BP-AA or SBS-AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -172.5 R-36 Existing fully bonded, mineral surface BUR or modified bitumen Min. 2-inch ACFoam II, FlintBoard ISO, ENRGY 3 or H-Shield A-PD, 6-inch o.c. Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board or Dens Deck A-PD, 6-inch o.c. BP-AA or SBS-AA, SBS-TA or APP-TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -172.5 R-37 Existing fully bonded BUR or modified bitumen roof cover Min. 1.5-inch ACFoam II, FlintBoard ISO, ENRGY 3 or H-Shield M-OSFA Min. 0.5-inch Structodek High Density Fiberboard M-OSFA BP-AA or SBS-AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -127.5 R-38 Existing fully bonded BUR or modified bitumen roof cover Min. 1.5-inch ACFoam II, FlintBoard ISO, ENRGY 3 or H-Shield M-OSFA Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board or Dens Deck M-OSFA BP-AA or SBS-AA, SBS-TA or APP-TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -157.5 R-39 Existing fully bonded, smooth- or granule-surface BUR or modified bitumen Min. 0.5-inch Structodek High Density Fiberboard M-PG1 None N/A BP-AA, SBS-AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -180.0 R-40 Existing fully bonded, smooth- or granule-surface BUR or modified bitumen Min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board M-PG1 None N/A BP-AA, SBS-AA, SBS-TA or APP-TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -180.0 R-41 Existing fully bonded BUR or modified bitumen roof cover Min. 1.5-inch ACFoam II, FlintBoard ISO, ENRGY 3 or H-Shield M-PG1 Min. 0.5-inch Structodek High Density Fiberboard M-PG1 BP-AA or SBS-AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -180.0 R-42 Existing fully bonded BUR or modified bitumen roof cover Min. 1.5-inch ACFoam II, FlintBoard ISO, ENRGY 3 or H-Shield M-PG1 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board or Dens Deck M-PG1 BP-AA or SBS-AA, SBS-TA or APP-TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -180.0 R-43 Existing fully bonded, smooth- or granule-surface BUR or modified bitumen Min. 0.5-inch Structodek High Density Fiberboard OB500 None N/A BP-AA, SBS-AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -120.0 R-44 Existing fully bonded, smooth- or granule-surface BUR or modified bitumen Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 None N/A BP-AA, SBS-AA, SBS-TA or APP-TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -120.0 R-45 Existing fully bonded BUR or modified bitumen roof cover Min. 1.5-inch ACFoam II, FlintBoard ISO, ENRGY 3 or H-Shield OB500 Min. 0.5-inch Structodek High Density Fiberboard OB500 BP-AA or SBS-AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -120.0 Exterior Research and Design, LLC. d/b/a Trinity|ERD Evaluation Report 3520.03.04-R20 for FL2533-R19 Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 20: 09/14/2017 Prepared by: Robert Nieminen, PE-59166 CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 651-5847 Appendix 1, Page 56 of 57 TABLE 7A: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER System No. Substrate (Notes 1 & 11) Base Insulation Layer Top Insulation Layer Roof Cover (Note 14) MDP (psf) Type Attach Type Attach Base Ply Cap R-46 Existing fully bonded BUR or modified bitumen roof cover Min. 1.5-inch ACFoam II, FlintBoard ISO, ENRGY 3 or H-Shield OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board, Dens Deck or Dens Deck Prime OB500 BP-AA, SBS-AA, SBS-TA or APP-TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -120.0 R-47 Existing fully bonded, smooth- or granule-surface BUR or modified bitumen Min. 0.5-inch Structodek High Density Fiberboard CR-20 None N/A BP-AA, SBS-AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -195.0 R-48 Existing fully bonded, smooth- or granule-surface BUR or modified bitumen Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board CR-20 None N/A BP-AA, SBS-AA, SBS-TA or APP-TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -195.0 R-49 Existing fully bonded BUR or modified bitumen roof cover Min. 1.0-inch ISO 95+ GL, H-Shield, H-Shield CG, ENRGY 3 or min. 1.3-inch ACFoam III, Min. 1.5-inch Multi-Max FA3 or Ultra-Max CR-20 Min. 0.25-inch Dens Deck or Dens Deck Prime CR-20 SBS-TA (Optional) SBS-TA SBS-TA -180.0 R-50 Existing fully bonded BUR or modified bitumen roof cover Min. 1.0-inch ISO 95+ GL, H-Shield, H-Shield CG, ENRGY 3 or min. 1.3-inch ACFoam III, Min. 1.5-inch Multi-Max FA3 or Ultra-Max CR-20 Min. 0.5-inch Structodek High Density Fiberboard or DuraBoard (homogeneous) or min. 1.5-inch FescoBoard (laminated) CR-20 BP-AA or SBS-AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -180.0 R-51 Existing fully bonded BUR or modified bitumen roof cover Min. 1.0-inch ISO 95+ GL, H-Shield, H-Shield CG, ENRGY 3 or min. 1.3-inch ACFoam III, Min. 1.5-inch Multi-Max FA3 or Ultra-Max CR-20 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board CR-20 BP-AA or SBS-AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -225.0 R-52 Existing fully bonded BUR or modified bitumen roof cover Min. 1.0-inch ISO 95+ GL, H-Shield, H-Shield CG, ENRGY 3 or min. 1.3-inch ACFoam III, Min. 1.5-inch Multi-Max FA3 or Ultra-Max CR-20 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board CR-20 SBS-TA or APP-TA (Optional) SBS-TA or APP-TA SBS-TA or APP-TA -232.5 R-53 Existing fully bonded BUR or modified bitumen roof cover Min. 1.0-inch ISO 95+ GL, H-Shield, H-Shield CG, ENRGY 3 or min. 1.3-inch ACFoam III, Min. 1.5-inch Multi-Max FA3 or Ultra-Max CR-20 Min. 0.25-inch Dens Deck CR-20 BP-AA or SBS-AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -240.0 COLD-APPLIED SYSTEMS: R-54 Existing fully bonded BUR or modified bitumen roof cover (Optional) Min. 0.5-inch ACFoam II, FlintBoard ISO, H-Shield, FlintBoard ISOH OB500 Min. 1.5-inch ACFoam III, FlintBoard Iso Cold, H-Shield CG or FlintBoard Iso ColdH OB500 SBS-CA1 None SBS-CA1 -82.5 R-55 Existing fully bonded BUR or modified bitumen roof cover (Optional) Min. 0.5-inch ACFoam II, FlintBoard ISO, H-Shield, FlintBoard ISOH CR-20 Min. 1.5-inch ACFoam III, FlintBoard Iso Cold, H-Shield CG or FlintBoard Iso ColdH CR-20 SBS-CA1 None SBS-CA1 -82.5 Exterior Research and Design, LLC. d/b/a Trinity|ERD Evaluation Report 3520.03.04-R20 for FL2533-R19 Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 20: 09/14/2017 Prepared by: Robert Nieminen, PE-59166 CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 651-5847 Appendix 1, Page 57 of 57 TABLE 7A: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER System No. Substrate (Notes 1 & 11) Base Insulation Layer Top Insulation Layer Roof Cover (Note 14) MDP (psf) Type Attach Type Attach Base Ply Cap R-56 Existing fully bonded, smooth- or granule-surface BUR or modified bitumen Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board A-PD, 6-inch o.c. None N/A SBS-CA1 None SBS-CA1 -105.0 R-57 Existing fully bonded, smooth surface BUR or modified bitumen Min. 0.5-inch ACFoam II, FlintBoard ISO, H-Shield, FlintBoard ISOH A-PD, 6-inch o.c. Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board A-PD, 6-inch o.c. SBS-CA1 None SBS-CA1 -52.5 R-58 Existing fully bonded, mineral surface BUR or modified bitumen Min. 0.5-inch ACFoam II, FlintBoard ISO, H-Shield, FlintBoard ISOH A-PD, 6-inch o.c. Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board A-PD, 6-inch o.c. SBS-CA1 None SBS-CA1 -105.0 R-59 Existing fully bonded, smooth- or granule-surface BUR or modified bitumen Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board M-PG1 None N/A SBS-CA1 None SBS-CA1 -105.0 R-60 Existing fully bonded, mineral surface BUR or modified bitumen Min. 0.5-inch ACFoam II, FlintBoard ISO, H-Shield, FlintBoard ISOH M-OSFA, M-PG1 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board M-OSFA, M-PG1 SBS-CA1 None SBS-CA1 -105.0 R-61 Existing fully bonded, smooth- or granule-surface BUR or modified bitumen Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 None N/A SBS-CA1 None SBS-CA1 -105.0 R-62 Existing fully bonded, mineral surface BUR or modified bitumen Min. 0.5-inch ACFoam II, FlintBoard ISO, H-Shield, FlintBoard ISOH OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 SBS-CA1 None SBS-CA1 -105.0 R-63 Existing fully bonded, smooth- or granule-surface BUR or modified bitumen Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board CR-20 None N/A SBS-CA1 None SBS-CA1 -105.0 R-64 Existing fully bonded, mineral surface BUR or modified bitumen Min. 0.5-inch ACFoam II, FlintBoard ISO, H-Shield, FlintBoard ISOH CR-20 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board CR-20 SBS-CA1 None SBS-CA1 -105.0 TABLE 7B: RECOVER APPLICATIONS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE F: NON-INSULATED, BONDED ROOF COVER System No. Substrate (Notes 1 & 11) Primer Roof Cover (Note 14) MDP (psf) Base Ply Cap R-65 Existing fully bonded BUR over structural concrete deck (Optional) FlintPrime (ASTM D41) SBS-CA1 None SBS-CA1 -187.5 !! !! !! !! !! !! !! ! ! ! ATTENTION:! ! PLEASE!DO!NOT!REMOVE! THIS!PACKET!FROM!DOOR! UNTIL!YOU!HAVE! CONTACTED!BIGFOOT! ROOFING!AT!904;751;6112.! ! ! ! INSPECTOR!WILL!FAIL!INSPECTIONS!IF!PAPERWORK! IS!REMOVED!PRIOR!TO!FINAL!INSPECTION.! ALL WEATHER/EMPIRE ™BASE SHEET MODIFIED BITUMEN COATED FIBER GLASS BASE SHEET Product Use:ALL WEATHER/EMPIRE Base Sheet is designed for use as a base sheet for both hot and cold applied, built-up roofing systems. It is suitable for use in the construction of various types of membranes for both new construction and reroofing, over a variety of substrates. ALL WEATHER/EMPIRE will provide additional strength, moisture resistance and asphalt uniformity when used as the first ply over nailable, non-nailable and insulated substrates. In addition, it will perform as a venting base sheet when spot mopped over plastic foam-type insulations. It is acceptable for use with both organic and inorganic roof membranes whenever a heavy duty base sheet is desired. ALL WEATHER/EMPIRE Base Sheet is also acceptable for use as a UL Classified underlayment beneath CertainTeed Symphony™Slate Roofing. Limitations: ALL WEATHER/EMPIRE Base Sheet may be applied in either hot asphalt or approved cold adhesive such as FlintBond™ depending on system design and selection. Rolls should be stored upright, off ground, completely protected from the weather. Roof decks shall be structurally sound, dry, smooth and meet or exceed minimum requirements of the deck manufacturer, local code and CertainTeed.Roof decks shall provide positive drainage. Additional specifications and precautions are contained in the CertainTeed Commercial Roof Systems Manual. Product Composition and Features:ALL WEATHER/ EMPIRE Base Sheet is manufactured on a durable, high-quality fiber glass mat that receives a coating of modified bitumen compound. The final product is lightly surfaced with a mineral release agent. The modified bitumen coating provides excellent moisture resistance and durability. ALL WEATHER/EMPIRE Base Sheet is pliable and will conform to most surfaces for ease of application. Applicable Standards:ALL WEATHER / EMPIRE Base Sheet is approved by Underwriters Laboratories for use in various Class A, B, or C roof assemblies, ICC-ES (ESR-1388), Factory Mutual, Miami-Dade, Florida Building Code Statewide Approval (FL 477 and FL 479). Consult www.certainteed.com/lowslopetechinfo for details. Meets ASTM D4601, Type II. The following information represents typical average properties of ALL WEATHER/EMPIRE Base Sheet: Support Mat: Fiber glass base mat. Surfacing: Mineral release agent. Approximate Product Weight: 70 Ibs. per roll. Dimensions: 393/8" X 65'10" (216 square feet). Coverage: Two squares. Thickness: 1.3mm (50 mils) Tensile @ 73°F: MD 85 XD 75. Pliability @ 77°F: Passed. Water-Vapor Permeance: < 0.3 perms. Technical Product Data ProductInformation Technical Data Roof systems constructed with ALL WEATHER/EMPIRE Base Sheet as the base ply shall be applied in accordance with installation procedures contained in the CertainTeed Commercial Roof Systems Manual. The following information is intended for general information purposes only and is not all-inclusive. Preparation:Substrates to receive a roof system shall be firmly attached, smooth, dry, clean and free of sharp projections and depressions. Flashing shall be in place and roof accessories available prior to application of materials. Substrates requiring priming shall be primed with asphalt primer such as FlintPrime™and be allowed to completely dry. Substrates shall provide positive drainage. Roof insulation shall be tapered to drains. Installation:ALL WEATHER/EMPIRE Base Sheet shall be installed with 2" side laps and 4" end laps, with end laps diagonally staggered not less than 3 feet apart. For nailable substrates, mechanically fasten ALL WEATHER/EMPIRE Base Sheet 9" o.c. at side laps and 18" o.c. in two rows, 12" in from each edge with approved fasteners. For non-nailable or insulated substrates, ALL WEATHER/EMPIRE Base Sheet shall be set in either a spot or solid mopping of bitumen as required by the CertainTeed Commercial Roof Systems Manual. Spot mopping, when specified, shall be applied in 9" diameter circles, 24" o.c. in all directions. Solid moppings shall be applied at the rate of 25 Ibs. per 100 sq. ft. Bitumen shall be heated and applied within temperature guidelines as set by CertainTeed according to type and grade. Precautions:Cold weather applications require special handling to prevent damage to the rolls and to ensure satisfactory installation. Do not apply roofing systems over improperly prepared substrates or substrates which contain moisture. Maintenance:CertainTeed Commercial Roof Systems do not require any additional maintenance beyond normal yearly roof maintenance procedures. CertainTeed recommends regular roof maintenance and inspection to determine the condition of drains, flashings and other similar items, and to prolong the life expectancy of the roof system. CertainTeed offers a number of different types of Roof Membrane Warranties designed to meet the building owner’s specific requirements. Please contact your nearest CertainTeed office for additional information and requirements. CertainTeed provides technical assistance in the design, selection, specification and application guidelines for all CertainTeed Commercial Roof Systems. Architectural and field representatives are available for consultation within each region. For more information, contact CertainTeed’s Customer Support at 800-233-8990. Product Application TechnicalAssistance andService Warranties © 2004 Rev 3/09 CertainTeed Corporation, Printed in U.S.A.Code No. COMM-026 CertainTeed Corporation P.O. Box 860 Valley Forge, PA 19482 Professional: 800-233-8990 www.certainteed.com ASK ABOUT OUR OTHER CERTAINTEED PRODUCTS AND SYSTEMS: EXTERIOR:ROOFING • SIDING • WINDOWS • FENCE • RAILING • TRIM • DECKING • FOUNDATIONS • PIPE INTERIOR:INSULATION • GYPSUM • CEILINGS Technical Product Data FLINTLASTIC ®GTA™ APP MODIFIED BITUMEN ROLL ROOFING PRODUCTS Product Use: FLINTLASTIC GTA is designed for use as a roofing membrane over various types of substrates for both new construction and reroofing installations. It is suitable for most low sloped roof decks and may be used for roof system flashings including wall treatments, base flashings and field flashings. Limitations:FLINTLASTIC GTA is intended for torch application only and should not be exposed to adhesives or solvent based materials. Rolls should be stored upright, off ground, completely protected from the weather. Roof decks shall be structurally sound, dry, smooth and meet or exceed minimum requirements of the deck manufacturer, local code and CertainTeed. Additional specifications and precautions are contained in the CertainTeed Commercial Roof Systems Manual. Product Composition and Features:FLINTLASTIC modified bitumen membranes are manufactured on state-of-the-art, dedicated roofing lines that were exclusively designed for the production of modified bitumen products. FLINTLASTIC GTA is produced with a high performance, non-woven polyester mat which is impregnated and coated with a superior grade, modified bitumen compound. Size:393/8" X 32'10"Coverage*:One square (*When applied according to CertainTeed’s specification) Approximate Weight:105 Ibs. per rollTop Surface:Mineral GranuleBack Surface:Torchable Polyethylene Film Applicable Standards: FLINTLASTIC GTA is approved by Underwriters Laboratories for use in various Class A, B, and C roof assemblies, ICC-ES (ESR-1388), Factory Mutual, Miami-Dade, Florida Building Code Statewide Approval (FL 479), and Texas Department of Insurance (RC-47). Consult www.certainteed.com/lowslopetechinfo for details. Meets ASTM D6222, Grade G, Type I. FLINTLASTIC GTA White is an approved ENERGY STAR®product for slopes greater than 2"/12". Initial Solar Reflectance: 0.27; Aged Solar Reflectance: 0.27; Thermal Emittance: 0.87. Modified Bitumen Coating:Non-oxidized (flux) asphalt, blended with various thermoplastic atactic polypropylene polymers and co-polymers. Support Mat:High performance, puncture and tear resistant, non-woven polyester mat. Test Description Test Method Results* Solar Reflectance Index (SRI):ASTM E1980 27 Softening Point:ASTM D36 310°F Tensile Strength:ASTM D5147 @ 73.4 +/- 3.6°F MD/XD 106/92 lbs./in. @ 0 +/- 3.6°F MD/XD 133/116 lbs./in. Elongation:ASTM D5147 @ 73.4 +/-3.6°F MD/XD 57%/62% @ 0 +/- 3.6°F MD/XD 20%/22% Dimensional Stability:ASTM D5147 MD/XD 0.5%/0.3% Low Temperature Flex:ASTM D5147 Pass @ 8°F Compound Stability:ASTM D5147 250°F Thickness:ASTM D5147 4.2mm (168 mils) Tear Strength:ASTM D5147@ 73.4 +/-3.6°F MD/XD 120/95 lbs. *NOTE: Published results are nominal production values confirmed by independent laboratory testing. ProductInformation Technical Data Initial Weathered Solar Reflectance 0.27 0.27Thermal Emittance 0.87 0.90 Rated Product ID 0008 Licensed Manufacturer ID 0668 Classification Production Linen Cool Roof Rating Council ratings are determined for a fixed set of conditions, and may not be appropriatefor determining seasonal energy performance. The actual effect of solar reflectance and thermal emittance on building performance may vary. Manufacturer of product stipulates that these ratings were determined in accordance with the applicable Cool Roof Rating Council procedures. FLINTLASTIC modified bitumen roofing systems shall be applied in accordance with installation procedures contained in the CertainTeed Commercial Roof Systems Manual. The following information is intended for general information purposes only and is not all-inclusive. Preparation:Substrates to receive a roof system shall be firmly attached, smooth, dry, clean and free of sharp projections and depressions. Substrates requiring priming shall be primed with asphalt primer such as CertainTeed’s FlintPrime™and be allowed to completely dry. Substrates shall provide positive drainage. Roof shall be tapered to drains. Installation:Install one ply of GLASBASE or other CertainTeed approved alternate base sheet lapping 2" on sides and 4" on ends. Base sheet shall be mechanically fastened to nailable substrates, and either solid or spot mopped in hot asphalt to non-nailable or insulated substrates as specified in the CertainTeed Commercial Roof Systems Manual. Apply base sheet in such a manner to provide and maintain a minimum 6" offset between side and end laps of base ply and FLINTLASTIC finishing membrane. Over the base ply, install one ply of FLINTLASTIC GTA lapping 3" on sides and 6" on ends with end laps diagonally staggered not less than 3 feet apart. Side and end laps should be inspected to ensure a minimum 3/8" flow of modified compound has been achieved. Precautions:Cold weather applications require special handling to prevent damage to the rolls and to ensure satisfactory installation. Do not apply roofing systems over improperly prepared substrates or substrates which contain moisture. Follow all safety recommendations relating to the use and maintenance of liquid propane gas torches and equipment. Refer to the CertainTeed Commercial Roof Systems Manual for additional safety information. Maintenance:FLINTLASTIC Roof Systems do not require any additional maintenance beyond normal yearly roof maintenance procedures. CertainTeed recommends regular roof maintenance and inspection to determine the condition of drains, flashings and other similar items, and to prolong the life expectancy of the roof system. CertainTeed offers a number of different types of Roof Membrane Warranties designed to meet the building owner's specific requirements. Please contact your nearest CertainTeed office for additional information and requirements. CertainTeed provides technical assistance in the design, selection, specification and application guidelines for all CertainTeed Roof Systems. Architectural and field representatives are available for consultation within each region. For more information, contact CertainTeed’s Customer Support at 800-233-8990. Torch application of this product may create a risk of FIRE, including SMOLDERING FIRES. The roofing applicator is solely responsible for ensuring and enforcing safe and proper application of CertainTeed’s roofing products by competent and qualified personnel. Only properly trained roofing professionals are authorized to install this product. Never apply flame directly to combustible materials or allow the flame to enter into hidden or protected areas that may contain combustible materials. Follow all local code requirements. Have a Class A-B-C fire extinguisher available to each applicator. Thoroughly inspect the job site whenever torching equipment has been used. Be certain that all chances of a fire have been eliminated. Refer to the CertainTeed Commercial Roof Systems Manual, Midwestern Roofing Contractors Association (MRCA) CERTA program, National LP Gas Association, National Roofing ContractorsAssociation (NRCA), National Fire Protection Association (NFPA), and Asphalt Roofing Manufacturers Association (ARMA) for further information and safety recommendations. Technical Assistance and Services Warranties Caution: Fire Hazard © 2000 Rev 11/09 CertainTeed Corporation, Printed in U.S.A.Code No. COMM-020 CertainTeed Corporation P.O. Box 860 Valley Forge, PA 19482 Professional: 800-233-8990 www.certainteed.com ASK ABOUT OUR OTHER CERTAINTEED PRODUCTS AND SYSTEMS: EXTERIOR:ROOFING • SIDING • WINDOWS • FENCE • RAILING • TRIM • DECKING • FOUNDATIONS • PIPE INTERIOR:INSULATION • GYPSUM • CEILINGS ProductApplication CC ee rr tt aa ii nn TTee ee dd Application Handbook CertainTeed Flintlastic®Modified Bitumen roofing products represent the finest in quality roofing materials. Beyond quality materials, proper application is the key to the successful performance of any roofing system. This pocket guide is intended as a handy reference tool only. It is not all-inclusive, and before installation of any Flintlastic Modified Bitumen Roof System the CertainTeed Commercial Roof Systems Manual must also be referenced. CertainTeed Flintlastic Modified Bitumen roofing products are intended for use by professional roofing contractors only. It is the sole responsibility of the applicator to exercise all appropriate safety precautions in the application and handling of roofing products utilizing torches, hot asphalt, cold adhesive and related equipment. For more information concerning safety contact the following agencies: NRCA (National Roofing Contractors Association) 10255 W. Higgins Rd., Ste. 600, Rosemont, IL 60018-5607 Ph. 847-299-9070 MRCA (Midwest Roofing Contractors Association) 4840 Bob Billings Parkway, Ste. 1000, Lawrence, KS 66049-3876 Ph. 800-497-6722 NERCA (North East Roofing Contractors Association) 150 Grossman Drive Street, Ste. 313, Braintree, MA 02184 Ph. 781-849-0555 WSRCA (Western States Roofing Contractors Association) 465 Fairchild Drive, Ste. 210, Mountain View, CA 94043 Ph. 800-725-0333/650-938-5441 ARMA (Asphalt Roofing Manufacturers Association) 1156 15th St. NW, Ste. 900, Washington, DC 20005 Ph. 202-207-0917 NFPA (National Fire Protection Association) 1 Batterymarch Park, Quincy, MA 02169-7471 Ph. 617-770-3000 Contents 2Flintlastic®Modified Bitumen Product Quick Reference Chart 4Material Handling and Storage Weather Precautions Roof Slope and Drainage Substrate Preparation 5Base Sheet Application 6Vapor Retarders Insulation 7Re-Cover Considerations Roof Relief Vents Proper Tools 8Proper Attire Roof Layout 10 Basic Application: Flintlastic APP Modified Bitumen 12 Flashing Details: Flintlastic APP Modified Bitumen 20 Basic Application: Flintlastic SBS Modified Bitumen 23 Flashing Details: Flintlastic SBS Modified Bitumen 29 Application of Flintlastic SA NailBase Application of Flintlastic SA Mid Ply or PlyBase 31 Before Installing Flintlastic SA Cap (or SA Cap FR) 32 Application of Flintlastic SA Cap (or SA Cap FR) 33 Some of the Accessory Products and Tools You’ll Need 34 Important Application Considerations 35 The Proper T-Seam Detail 36 Typical Construction Details (Flintlastic SA 2-Ply System) 42 Typical Construction Details (Flintlastic SA 3-Ply System) 46 Job Completion Safety Tips 52 Reference Tables 1 What’s in a name? Each roll of CertainTeed Flintlastic Modified Bitumen has a 3-letter identification code in its name. Example: Flintlastic GTS CertainTeed Flintlastic Modified Bitumen Product Quick Reference Chart Mineral surfaced cap sheets are also available with CoolStar™, factory-appplied ENERGY STAR®coating. 2 1st letter designates surface, SMOOTH or GRANULAR 2nd letter designates application process, TORCH or MOP 3rd letter designates modifier, SBS or APP Product Type Specs Uses GlasBase™Fiber glass; Type G2 3 sq.roll; 75 lbs./roll Base sheet FlexiGlas™Fiber glass; Type G2 3 sq.roll; 90 lbs./roll Base sheet Base Sheet or Mid Ply Flintlastic®FR SBS Modified,1 sq. roll; 81 lbs./roll Base sheet Base T fiber glass reinforced Flintlastic®SA SBS Modified, self-adhering, 2 sq. roll; 88 lbs./roll Base sheet PlyBase fiber glass reinforced Flintlastic®SA SBS Modified,2 sq. roll; 84 lbs./roll Base sheet NailBase fiber glass reinforced All Weather/ SBS Modified,2 sq. roll; 70 lbs./roll Base sheet Empire™Base fiber glass Yosemite®Fiber glass 1 sq. roll; 85 lbs./roll Buffer base sheet Buffer Base Black SBS Modified,2 sq. roll; 75 lbs./roll Self-adhering base Diamond®Base fiber glass reinforced;or mid ply with fine Type G2 mineral particle surfacing Channel Vent™Fiber glass base sheet with 1 sq. roll; 78 lbs./roll Base sheet with channels for lateral venting ventilating capability Flintlastic®SBS base sheet,2 sq. roll; 90 lbs./roll Base sheet or Poly SMS™polyester reinforced Mid Ply sheet Flintlastic®Premium, heavy SBS base 1 sq. roll; 90 lbs./roll Base sheet or Ultra Poly SMS™sheet, polyester reinforced Mid Ply sheet Flintlastic®SA SBS Modified, self-adhering, 1 sq. roll; 68 lbs./roll Mid Ply sheet Mid Ply polyester fiber glass, reinforced Flexiglas™SBS Modified,1 sq. roll; 100 lbs./roll Mineral surfaced Premium Cap 960 fiber glass, reinforced Cap sheet Flintlastic®FR SBS Modified,1 sq. roll; 100 lbs./roll Mineral surfaced Cap T fiber glass, reinforced fire rated Cap sheet Flintlastic®SA Cap SBS Modified, self-adhering, 1 sq. roll; 97 lbs./roll Mineral surfaced fiber glass, reinforced Cap sheet 3 Product Type Specs Uses Flintlastic®SA SBS Modified, self-adhering, 1 sq. roll; 90 lbs./roll Fire rated, mineral Cap FR fiber glass, reinforced surfaced Cap sheet Flintlastic®GTA APP Modified,1 sq. roll; 105 lbs./roll Mineral surfaced polyester reinforced Cap sheet Flintlastic®STA APP Modified,1 sq. roll; 90 lbs./roll Smooth surfaced Cap polyester reinforced or Mid Ply sheet Flintlastic®GTS SBS Modified,3/4 sq. roll; 90 lbs./roll Mineral surfaced polyester reinforced Cap sheet Flintlastic®GMS SBS Modified,1 sq. roll; 100 lbs./roll Mineral surfaced polyester reinforced Cap sheet Flexiglas™FR Base SBS Modified,1.5 sq. roll; 90 lbs./roll Base sheet fiber glass reinforced Flintglas®Cap Fiber glass; Type G3 1 sq. roll; 78 lbs./roll Mineral surfaced Cap sheet Flintglas®Ply 4 Fiber glass; Type G1 5 sq. roll; 38 lbs./roll Mid Ply sheet Flintglas®Fiber glass; Type G1 5 sq. roll; 48 lbs./roll Mid Ply sheet Premium Ply 6 Flintlastic®STA APP Modified,1 sq. roll; 95 lbs./roll Mineral surfaced White Diamond GTA polyester reinforced Cap sheet Flintlastic®FR Cap SBS Modified,1 sq. roll; 90 lbs./roll Mineral surfaced fiber glass reinforced Cap sheet Flintlastic®FR-P SBS Modified,1 sq. roll; 105 lbs./roll Mineral surfaced polyester reinforced Cap sheet Flintlasticv GTA-FR APP Modified,1 sq. roll; 105 lbs./roll Mineral surfaced polyester reinforced Cap sheet Flintlastic®SBS Modified,1 sq. roll; 105 lbs./roll Mineral surfaced Premium FR-P polyester reinforced Cap sheet Flintlastic®SBS Modified,1 sq. roll; 105 lbs./roll Mineral surfaced Premium GMS polyester reinforced Cap sheet Flintlastic®APP Modified,1 sq. roll; 100 lbs./roll Smooth surfaced STA Plus polyester reinforced Cap sheet Material Handling and Storage • Store rolls upright on pallet in dry area. • Store indoors in a ventilated area. • Keep rolls protected from exposure to heat, sun, cold and moisture. • Do not double stack pallets. • Do not store rolls on their sides. • Use care in the handling of the rolls. • Do not overload the roof. Stagger the rolls across the roof. Avoid excessive weight in a concentrated area. Weather Precautions Do not attempt application if weather conditions and substrate are not dry. Do not attempt application if ice, frost, moisture or snow is present. Rolls can be installed in cold weather if conditions are dry, the rolls have not been allowed to freeze and proper cold weather handling and storage procedures are followed. Store rolls in a heated area until just prior to use and do not proceed with installation if rolls have been allowed to freeze or weather conditions are unsuitable. In extremely warm weather, use caution when walking on freshly installed material to avoid ”tracking” warm asphalt; when torch applying smooth APP membrane in very warm weather the installer can walk beside the sheet being applied (as is the standard torch method with mineral surfaced APP and SBS membrane) to avoid tracking. Roof Slope and Drainage All roof decks to which the Flintlastic modified bitumen roof system is to be installed must have a minimum slope of 1/4" per foot (as recommended by the NRCA) and must have positive drainage. See also “Roof Layout” on page 8 of this handbook. Greater slope may be necessary as part of the structural design, depending upon the particular building, to accommodate rapid and thorough run-off of precipitation. Substrate Preparation All surfaces to which the Flintlastic modified bitumen is to be installed must be smooth, dry, free from dust or debris, free from settling or distortion, and free from cracks, knotholes, or other defects. Primer Concrete decks must be properly primed with suitable asphalt primer (meeting ASTM D-41) and the primer must be thoroughly dry. 4