Loading...
156 Seminole Road- MCRS22-0012 Solar PV Plans revision 8-30-22_1Godwin Engineering and Design, LLC 8378 Foxtail LoopPensacola, FL 32526D. Chad Godwin, PEChad@godwineng.com R-1 # Modules (18) Pitch: 0°Azimuth: 292° 6'-10" 3'-5" FRONT OF HOUSE R-1 6/28/2022 AZ 8/19/2022 AZ Meets all requirements of NFPA-1 7th Edition and NFPA-101 3' Access Pathway 1st Responder Accessminimum of 36" unobstructed as perSection R324 of the 2020 IRC Customer Info: 11"x17" S-1 Date:Drawn by:Revised by:Rev #: 01Rev Date:Page: Represents all Fire Clearance including Alternative methods Utility Meter Meets the requirements of the following- (2020 FL Residential Code & FBC, 7th Edition (2020 International Residential Code) - 2nd Printing modified by the FL Building Standards, 2020 Florida Building EnergyConservation Code 7th edition, City of Atlantic Beach Code, 2017 National Electric Code.) Legend First responder access Sheet IndexS-1 Cover Sheet / Site PlanS-2 DetailE-1 One - LineE-2 Electrical CodeS-1A Mounting Plan Utility Meter PV Disconnect Vent Pipe Chimney Satellite N -COGEN Disconnect Located adjacent toUtility meter Inverter Type:PV Panel:Racking:Total Wattage:Roof Type:Wind Load:Fastener Type: Iron Ridge XR-10 Use Roof Tech Minis (18)Enphase IQ8A-72-2-US(18) Sunpal SP460M-72HB 8,280W DCEPDM0 to 7 Deg F R O N T O F H O U S E Layout Subject to Change Based on Site Conditions Meets All Editions of Florida Fire Prevention Code 2020 7th Edition Compass for Aerial System meets the requirements of NFPA 70th Edition, Chapter 11.12 Install will be done to Manufacturer Spec David Siefken156 Seminole Road Atlantic Beach, FL32233 General Notes:-Enphase IQ8A-72-2-US Micro Inverters are located on roof behind each module.-First responder access maintained andfrom adjacent roof.-Wire run from array to connection is 40 feet. Ground Access 3'1'-6" -New MSP Located adjacent toUtility meter Tesla Backup Gateway 125A Generation Panel Enphase Combiner Box Interior PanelTesla Powerwall BatteryLocated Inside Utility Room Smoke Alarms and/or Heat Detectors will beInstalled in Utility Room Donnie C Godwin 2022.08.1 9 10:00:50 '00'05- By Toni Gindlesperger at 3:41 pm, Aug 30, 2022 By Mike Jones at 8:59 am, Sep 01, 2022 8:59 am, Sep 01, 2022 Godwin Engineering andDesign, LLC8378 Foxtail Loop Pensacola, FL 32526 D. Chad Godwin, PEChad@godwineng.com 6/28/2022 AZ . . -Roof Height 15' -Per 2020 FBC, the Roof Mounted PV System will be subject to the following design criteria: Design Wind Speed(Vult) - 130mph 3 sec gust, Exposure Category - C-Designed as per ASCE7-16 Customer Info: 11"X17" S-2 Date:Drawn by:Revised by:Rev #: 00Rev Date:Page: Inverter Type:PV Panel:Racking:Total Wattage: Roof Type: Wind Load:Fastener Type: Iron Ridge XR-10 Use Roof Tech Minis (18)Enphase IQ8A-72-2-US(18) Sunpal SP460M-72HB 8,280W DCEPDM0 to 7 Deg Install will be done to Manufacturer Spec David Siefken 156 Seminole RoadAtlantic Beach, FL 32233 General Notes: - Roof Tech Mini II are secured to rafters using (2) M5 x 60mm stainless steel Lag bolts. - Subject roof has One layer. All penetrations are sealed. Roof Section Pitch Roof Rafter and Spacing Overhang Notes: R1 0/12 2"x6" @ 16 O.C.12"Truss Ironridge XR-10 @ 48" O.C. in Zone 1', @ 48" O.C in Zone 1, @ 32" O.C. in Zone 2, @ 16" O.C. in Zone 3 Roof Tech Mini II Donnie C Godwin 2022.08.19 '00'05- 10:01:18By Toni Gindlesperger at 3:41 pm, Aug 30, 2022 Godwin Engineering andDesign, LLC 8378 Foxtail Loop Pensacola, FL 32526D. Chad Godwin, PEChad@godwineng.com 6/28/2022 AZ . . In Case of Emergency Call Go Solar Powerat 800-530-9597EC 13007879 CVC56962 Customer Info: 11"x17" E-1 Date:Drawn by:Revised by:Rev #: 00Rev Date:Page: GEC NOTES- Ungrounded system per 690.41(A)(4)- GEC must be installed per 250.64- GEC must be continuous un-spliced or irreversibly spliced frominverter to existing service ground system or continuous from thearrays to the existing service ground system.- GEC must be min #8 AWG and installed in conduit- If GEC is not in conduit, it must be #6 min Install will be done to Manufacturer Spec Including the label below David Siefken 156 Seminole Road Atlantic Beach, FL 32233 Inverter Type:Enphase IQ8A-72-2-USPV Panel:(18)Sunpal SP460M-72HBTotal Wattage:8,280W DC #10 AWG THWN for Home runs over 100'(1) Line 1(1) Line 2Per Circuit #8 AWG THWN(1) EGCInside @ least 3/4" Conduit (tbd on site) Photovoltaics: (18) Sunpal SP460M-72HB Inverters: (18) Enphase IQ8A-72-2-US Micro Inverters Circuits:(2) circuits of (9) Modules Maximum Inverters Per 20A Circuit (11)Roof NEC LABEL NOTES: 1. THE WARNING SIGN(S) OR LABEL(S) SHALL COMPLY WITH NEC 110.21(B) 2. LABELS SHALL BE SUITABLE FOR THE ENVIRONMENT WHERE THEY ARE INSTALLED. 3. LABELS TO BE A MIN LETTER HEIGHT OF 3/8" AND PERMANENTLY AFFIXED. 4. LABELS SHALL ALSO COMPLY WITH THE SPECIFIC REQUIREMENTS OF THE AUTHORITY HAVING JURISDICTION. NEMA 3R Junction BoxBlack - L1Red - L2Green - Ground Enphase IQ Trunk CableQ-12-240 #12AWG THHN-THWN-2 UL 9703 Grounding Conductorto be bare #8 Awg Tesla BackupGateway Interior Panel AC Max Output Current AC Max Output Current * 1.25%Overcurrent Protection (A)No. of Current Carrying CondConductor Gauge (AWG) 13.0516.3120<410 Enphase Output Ckt Per String To Overcurrent Protection Device Enphase Total Output Ckt AC Max Output CurrentAC Max Output Current * 1.25% Overcurrent Protection (A)No. of Current Carrying CondConductor Gauge (AWG) 26.132.6340<4 8 Each Telsa Power Wall Output Ckt AC Max Output Current AC Max Output Current * 1.25%Overcurrent Protection (A)No. of Current Carrying CondConductor Gauge (AWG) 243030<410 Combined Total Output Ckt AC Max Output CurrentAC Max Output Current * 1.25% Overcurrent Protection (A)No. of Current Carrying CondConductor Gauge (AWG) 50.162.6370<4 4 Note: -All wiring to meet the 2017 NEC andFlorida electric codes.100A Disconnect-Type of conduit to be determined on site by contractor. All Labels & Markings for photovoltaic system will bereflective and meet all requirements for NFPA 11.12 150A Disconnects will be Visible, lockable, adjacent toand within 10' of utility meter Meets 11.12.2.1.5 #1 AWG THWN(1) Line 1(1) Line 2(1) Neutral #6 (1) EGCin @ least 1.25"Conduit Typically PHOTOVOLTAIC SYSTEM ! AC DISCONNECT ! RATED AC OUTPUT CURRENT: 50.1A NOMINAL OPERATING VOLTAGE: 240VAC M GEC #1 AWG THWN(1) Line 1(1) Line 2(1) Neutral #6 (1) EGCin @ least 1.25"Conduit Typically No loads to be added to meter main combo New Main Service 150A Main 200A Bus #8 AWG THWN(2) Hot(1) Neutral #8 AWG EGCin @ least 3/4" Conduit Typically 30A #10 L1,L2,N#10 GroundIn Min 3/4"Conduit 40A (1) 13.5kWhTelsa PowerWallNEMA 3R 100A Service RatedFused DisconnectAC Disconnect 70A Fuse Manual Disconnect #4 AWG THWN(1) Line 1(1) Line 2(1) Neutral #8 (1) EGCin @ least 1" Conduit Typically 125A Generation Panel Enphase Combiner Box (1) - 20A BreakerPer Circuit #X-IQ-AM1-240Solar Combiner Box 240V125A Rated 2 Circuits Disconnect10/15A Breaker for Envoy Donnie C Godwin 2022.08. 19 10:01:35 '00'05- By Toni Gindlesperger at 3:41 pm, Aug 30, 2022 Godwin Engineering andDesign, LLC 8378 Foxtail Loop Pensacola, FL 32526D. Chad Godwin, PEChad@godwineng.com 6/28/2022 AZ . . In Case of Emergency Call Go Solar Powerat 800-530-9597EC 13007879 CVC56962 In Case of Emergency CallGo Solar Powerat 800-530-9597EC 13007879 CVC56962 Customer Info: 11"x17" E-2 Date:Drawn by:Revised by:Rev #: 00Rev Date:Page:Install will be done to Manufacturer Spec Including the label below David Siefken 156 Seminole Road Atlantic Beach, FL 32233 Inverter Type:Enphase IQ8A-72-2-USPV Panel:(18)Sunpal SP460M-72HBTotal Wattage:8,280W DC System meets the grounding requirements of NEC 690.43 Note:-Subject PV Systems has been designedto meet the requirments of the NEC 2017, and those set forth by the Florida SolarEnergy Center Certification, IncludingMaximum Number of Module Strings,Maximum number of modules per string,Maximum Output, Module Manufacturer andmodel number, inverter manufacturer and modelnumber, as applicable. Rapid Shutdown Built inPer Code NEC 690.12 Conductors have a min ampacity of 60 amperesPer Code NEC 230.79(D) PV AC disconnect islockable in the open positionper code NEC 705.22(7) Labels will be placedin the correct locationPer Code NEC 690.56(B),690.56(C), & 690.53 Include required label for metallic raceways and conduits to sheet E-1 per NEC article 690.31(G)(3). Add required label to sheet E-1 per NEC article 705.10. Include required label to sheet E-1 per NEC article 705.12(B) Photovoltaic AC disconnect shall be capable of being locked in the open position per NEC article 705.22(6). Photovoltaic AC Overcurrent protection shall be located within 10 feet of the point where conductors are connected to the service per NEC 705.31. 705.12(B)(3) 705.12(B)(2)(3)(b) NEC 705.10 A permanent plaque or directory, denoting the location ofall electric power source disconnecting means on or in the premises, shallbe installed at each service equipment location and at the location(s) ofthe system disconnect(s) for all electric power production sources capableof being interconnected. One sign required for each PV system. -Markings Shall Be reflective, Weather Resistant and suitable for the environment. -Markings Shall be red with white lettering with minimum 38" Capital Letters Disconnect means shall be provided for all disconnecting all ungrounded conductors that supply or pass through the building or structure Per Code2017 NEC Section 225.31 & Section 225.32 In compliance with NEC250.58, NEC 690.8,NEC 250.24, NEC250.24(D) NEC 690.31 (G)(3) NEC 690.13 E04. Construction documents specify PV system circuits installed on or in buildings include a rapid shutdown function that controls specific conductors in accordance with NEC article 690.12. E05. These construction documents specify that a label is provided with the method to initiate rapid shut down per 690.12(4). E06. Construction drawings specify buildings or structures with both utility service and a PV system, complying with NEC article 690.l2 shall have a permanent plaque or directory including the following wording: “PHOTO VOLTAIC SYSTEM EQUIPPED WITH RAPID SHUTDOWN” as per NEC article 690.56 (C). E07. Construction documents specify PV power circuit labels shall appear on every section of the wiring system that is separated by enclosures, walls, partitions, ceilings, or floors. E08. Construction documents specify all warning sign(s) or label(s) shall comply with NEC article 110.21 (B). Label warnings shall adequately warn of the hazard. Labels shall be permanently affixed to the equipment, and Labels required shall be suitable for the environment. Markings shall be placed on all DC Conduits, DC Combiners,Raceways, Enclosures, Junction Boxes, and Cable Assembliesat every 10', turns, and above and below penetrations incompliance with NFPA System is in compliance with FFPC 1:11.12 7th Edition. Smoke Detectors will be added as per FBC 553.883 Permanent sticker added to disconnectApply to Main Disconnect Figure 690.56(C)(1)(a) Label for PV Systems that Shut down the array and the conductors leaving the array Disconnect is in compliance 230.72 Supply side disconnect adjacent to Msp Over Current Protection Device is "Next size up" Based on Inverter Maximum Continuous Output Current Rating 2017 NEC 240.4(B) All Exterior equipment is A minimum of Nema-R3 Rated All Interactive System(S) Points of interconnection with other sources shall be marked at an accesible location at the disconnecting means as a power source and with the rated ac output current and the nominal operating AC voltage. Per NEC 690.54 -A placard will be added withinstructions and locations to bein compliance with 690.12,690.56(B) and NEC 705.10 -All new equipmentlocated adjacent toMeter on exterior wall Everything will be built to Code without all Specifics labeled on plan In compliance with 230.71 The Placard shall be permanentlyriveted..., and shall be made of red,weatherproof, hard plastic, withengraved white block lettering. WARNING: DUAL POWER SUPPLY SOURCES: UTILITY GRID AND PV SOLAR ELECTRIC SYSTEM WARNING: INVERTER OUTPUT CONNECTION: DO NOT RELOCATE THIS OVERCURRENT DEVICE PHOTOVOLTAIC SYSTEM EQUIPPED WITH RAPID SHUTDOWN WARNING: DEDICATED SOLAR PANEL DO NOT CONNECT ANY OTHER LOADS WARNING:PHOTOVOLTAIC POWER SOURCE SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY. SOLAR ELECTRICPV PANELS 3/8 IN MIN. TEXT 3/16 IN MIN. TEXT ! WARNING ! POWER SOURCE OUTPUT CONNECTION: DO NOT RELOCATE THIS OVERCURRENT DEVICE Plans Satisfy NEC 250.94 & NEC250.53(A)(2) Combiner box in compliance Per Code NEC 705.12 2* 20A < 125A*No other loads to be added Solar will be installed into the Lugs of the Tesla Gateway located adjacentto Utility Meter J-Box not penetrating roofJ-Box not penetrating roof Smoke Alarms per F.S. 553.883 -All Electrical Service Equipment shall be located at or aboveBFE+1' or 8.00' NAVD Donnie C Godwin 2022.08.19 '00'05- 10:01:51 By Toni Gindlesperger at 3:41 pm, Aug 30, 2022 Godwin Engineering and Design, LLC8378 Foxtail LoopPensacola, FL 32526 D. Chad Godwin, PEChad@godwineng.com 14' Splice Bar Iron Ridge UFO'sIron Ridge Sleeves/End Caps Iron Ridge Ground Lugs Iron Ridge XR-10 Rail Sunpal SP460M-72HB Enphase IQ8A-72-2-US 6x6 J-Box Roof Tech Mini II 70A Fuses Enphase Combiner Box 100A Fused Disconnect 20A 2P Breaker 7' 4' R-1 # Modules (18) Pitch: 0° Azimuth: 292° 6'-10" 3'-5" 59'-4" 21'-11" L L L L L L L L L L L L L L L LL L L L L L L L L L L L L L L L L LL L 125A Generation Panel30A Breaker40A BreakerTesla Powerwall BatteryTesla Backup Gateway200A Meter-Main Combo 150A Main Breaker 6/28/2022 AZ . . Customer Info: 11"x17" S-1A Date:Drawn by:Revised by:Rev #: 00Rev Date:Page: Inverter Type: PV Panel: Racking: Total Wattage:Roof Type:Wind Load:Fastener Type: Iron Ridge XR-10 Use Roof Tech Minis (18)Enphase IQ8A-72-2-US (18) Sunpal SP460M-72HB 8,280W DCEPDM0 to 7 Deg Install will be done to Manufacturer Spec David Siefken 156 Seminole Road Atlantic Beach, FL 32233 Plans satisfy zones FBC-1510.7.1 L Proposed Mounting locations Max cantilever is 16" as per manufacturer spec. Max Cantilever = Max Span * (13)=48"*(13)=16"Zone 1': Zone 1: Zone 2: Max cantilever is 16" as per manufacturer spec. Max Cantilever = Max Span * (13)=48"*(13)=16" Max cantilever is 10.67" as per manufacturer spec. Max Cantilever = Max Span * (13)=32"*(13)=10.67" Zone 3:Max cantilever is 5.33" as per manufacturer spec. Max Cantilever = Max Span * (13)=16"*(13)=5.33" Donnie C Godwin 2022.08.19 '00'05- 10:02:20 By Toni Gindlesperger at 3:42 pm, Aug 30, 2022 425~460WHigh Efficiency LowLID Mono PERC withMBB & Half-cut TechnologyQuality GuaranteeSP460M-72HB25years Warranty for Materials and ProcessingSunpal PowerPositive power tolerance(0 +5W) guaranteed(up to 21.1%)Slower power degradation0.55% year 2-25Solid PID resistanceReduced resistive lossHigher energy yieldReduced hot spot riskQuality Guarantee25yearsWarrantyforMaterials andProcessing21.1%0~+5WPositive Tolerance91.2%87.7%84.5%80.7%98.0%100%105115 20 25 yearBlack1038425~460WSP460M-72HBSunpal PowerCell OrientationJunction BoxOutput CableGlass Frame Weight:DimensionPackaging144 (6x24)20~+5W,1.2meter in length,40mm45±2°CII5400Pa3600PaOperational TemperaturePower Output ToleranceVoc & Isc ToleranceMax. System VoltageMax. Series Fuse RatinNOCTSafety ClassFire RatingMax. Static Load(Front)Max. Static Load(Back)Electrical CharacteristicsDesign (mm)Model NumberTesting ConditionMaximum Power (Pmax/W)Open Circuit Voltage (Voc/V)Short Circuit Current (Isc/A)Voltage at Maximum Power (Vmp/V)Current at Maximum Power (Imp/A)2222222222222Voltage(V)Voltage(V)Voltage(V)14121064205004504002502001501005001412106420Power (W)SP425M-72HB20.020.220.520.7SP430M-72HB SP435M-72HB SP440M-72HB SP445M-72HB SP450M-72HB SP455M-72HB-0.270%/°C42540.510.5040.710.5745.510.6445.744011.4641.110.7144546.045011.6041.546.245511.6641.746.421.1SP460M-72HB46046.6I-V CurveCurrent-Voltage Curve(SP440M-72HB)Current-Voltage Curve(SP440M-72HB)Current-Voltage Curve(SP440M-72HB)Black209413009004009899144.53.57103535352535BBDCAACDB-BBy Toni Gindlesperger at 3:42 pm, Aug 30, 2022 IQ8M and IQ8A MicroinvertersOur newest IQ8 Microinverters are the industry’s first microgrid-forming, software-defined microinverters with split-phase power conversion capability to convert DC power to AC power efficiently. The brain of the semiconductor-based microinverter is our proprietary application-specific integrated circuit (ASIC) which enables the microinverter to operate in grid-tied or off-grid modes. This chip is built in advanced 55nm technology with high speed digital logic and has super-fast response times to changing loads and grid events, alleviating constraints on battery sizing for home energy systems.Part of the Enphase Energy System, IQ8 Series Microinverters integrate with the Enphase IQ Battery, Enphase IQ Gateway, and the Enphase App monitoring and analysis software.IQ8 Series Microinverters redefine reliability standards with more than one million cumulative hours of power-on testing, enabling an industry-leading limited warranty of up to 25 years.Connect PV modules quickly and easily to IQ8 Series Microinverters using the included Q-DCC-2 adapter cable with plug-n-play MC4 connectors.IQ8 Series Microinverters are UL Listed as PV Rapid Shut Down Equipment and conform with various regulations, when installed according to manufacturer’s instructions.Easy to install• Lightweight and compact with plug-n-play connectors• Power Line Communication (PLC) between components• Faster installation with simple two-wire cablingHigh productivity and reliability• Produce power even when the grid is down*• More than one million cumulative hours of testing• Class II double-insulated enclosure• Optimized for the latest high-powered PV modulesMicrogrid-forming• Complies with the latest advanced grid support**• Remote automatic updates for the latest grid requirements• Configurable to support a wide range of grid profiles• Meets CA Rule 21 (UL 1741-SA) requirements© 2022 Enphase Energy. All rights reserved. Enphase, the Enphase logo, IQ8 Microinverters, and other names are trademarks of Enphase Energy, Inc. Data subject to change. IQ8MA-DS-0003-01-EN-US-2022-03-17 * Only when installed with IQ System Controller 2, meets UL 1741.** IQ8M and IQ8A supports split phase, 240V installations only.DATA SHEET(1) No enforced DC/AC ratio. See the compatibility calculator at https://link.enphase.com/module-compatibility (2) Maximum continuous input DC current is 10.6A (3) Nominal voltage range can be extended beyond nominal if required by the utility. (4) Limits may vary. Refer to local requirements to define the number of microinverters per branch in your area.IQ8M and IQ8A MicroinvertersINPUT DATA (DC)IQ8M-72-2-USIQ8A-72-2-USCommonly used module pairings1W260 – 460295 – 500Module compatibility60-cell/120 half-cell, 66-cell/132 half-cell and 72-cell/144 half-cellMPPT voltage rangeV33 – 4536 – 45Operating rangeV25 – 58Min/max start voltageV30 / 58Max input DC voltageV60Max DC current2 [module Isc]A15Overvoltage class DC portIIDC port backfeed currentmA0PV array configuration 1x1 Ungrounded array; No additional DC side protection required; AC side protection requires max 20A per branch circuitOUTPUT DATA (AC)IQ8M-72-2-USIQ8A-72-2-USPeak output powerVA330366Max continuous output powerVA325349Nominal (L-L) voltage/range3V240 / 211 – 264Max continuous output currentA1.351.45Nominal frequencyHz60Extended frequency rangeHz50 – 68AC short circuit fault current over 3 cycles Arms2Max units per 20 A (L-L) branch circuit411Total harmonic distortion<5%Overvoltage class AC portIIIAC port backfeed currentmA30Power factor setting1.0Grid-tied power factor (adjustable) 0.85 leading – 0.85 laggingPeak efficiency%97.697.6CEC weighted efficiency%9797.5Night-time power consumptionmW60MECHANICAL DATAAmbient temperature range-40ºC to +60ºC (-40ºF to +140ºF)Relative humidity range4% to 100% (condensing)DC Connector typeMC4Dimensions (HxWxD)212 mm (8.3”) x 175 mm (6.9”) x 30.2 mm (1.2”)Weight1.08 kg (2.38 lbs)CoolingNatural convection – no fansApproved for wet locationsYesPollution degreePD3EnclosureClass II double-insulated, corrosion resistant polymeric enclosureEnviron. category / UV exposure ratingNEMA Type 6 / outdoorCOMPLIANCECertificationsCA Rule 21 (UL 1741-SA), UL 62109-1, UL1741/IEEE1547, FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO. 107.1-01This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC 2014, NEC 2017, and NEC 2020 section 690.12 and C22.1-2018 Rule 64-218 Rapid Shutdown of PV Systems, for AC and DC conductors, when installed according to manufacturer’s instructions.IQ8MA-DS-0003-01-EN-US-2022-03-17By Toni Gindlesperger at 3:42 pm, Aug 30, 2022 X-IQ-AM1-240-4The Enphase IQ Combiner 4/4C with Enphase IQ Gateway and integrated LTE-M1 cell modem (included only with IQ Combiner 4C) consolidates interconnection equipment into a single enclosure and streamlines IQ microinverters and storage installations by providing a consistent, pre-wired solution for residential applications. It offers up to four 2-pole input circuits and Eaton BR series busbar assembly.Enphase IQ Combiner 4/4CX-IQ-AM1-240-4 X-IQ-AM1-240-4CTo learn more about Enphase offerings, visit enphase.comData SheetEnphase NetworkingSmart• Includes IQ Gateway for communication and control• Includes Enphase Mobile Connect cellular modem (CELLMODEM-M1-06-SP-05), included only with IQ Combiner 4C• Includes solar shield to match Enphase IQ Battery EIWXLIXMGWERHHIƥIGXLIEX• Flexible networking supports Wi-Fi, Ethernet, or cellular• Optional AC receptacle available for PLC bridge• Provides production metering and consumption monitoringSimple• Centered mounting brackets support single stud mounting• Supports bottom, back and side conduit entry• Up to four 2-pole branch circuits for 240 VAC plug-in breakers (not included)• 80A total PV or storage branch circuitsReliableŵ (YVEFPI2680GIVXMƤIH2)1%X]TI6IRGPSWYVI• Five-year limited warranty• Two years labor reimbursement program coverage included for both the IQ Combiner SKU's•UL listedX-IQ-AM1-240-4CXIQAM1240X-IQ-AM1-240-40-4C04CTo learn more about Enphase offerings, visit enphase.com© 2021 Enphase Energy. All rights reserved. Enphase, the Enphase logo, IQ Combiner 4/4C, and other names are trademarks of Enphase Energy, Inc. Data subject to change. 10-21-2021MODEL NUMBERIQ Combiner 4 (X-IQ-AM1-240-4)IQ Combiner 4 with Enphase IQ Gateway printed circuit board for integrated revenue grade PV production metering (ANSI C12.20 +/- 0.5%) and consumption monitoring (+/- 2.5%). Includes a silver solar shield to match the IQ Battery system and -57]WXIQ'SRXVSPPIVERHXSHIƥIGXLIEXIQ Combiner 4C (X-IQ-AM1-240-4C)IQ Combiner 4C with Enphase IQ Gateway printed circuit board for integrated revenue grade PV production metering (ANSI C12.20 +/- 0.5%) and consumption monitoring (+/- 2.5%). Includes Enphase Mobile Connect cellular modem (CELLMODEM-M1-06-SP-05), a plug-and-play industrial-grade cell modem for systems up to 60 microinverters. (Available in the US, Canada, Mexico, Puerto Rico, and the US Virgin Islands, where there is adequate cellular service in XLIMRWXEPPEXMSREVIE -RGPYHIWEWMPZIVWSPEVWLMIPHXSQEXGLXLI-5&EXXIV]ERH-57]WXIQ'SRXVSPPIVERHXSHIƥIGXLIEXACCESSORIES AND REPLACEMENT PARTS(not included, order separately)Ensemble Communications Kit COMMS-CELLMODEM-M1-06 CELLMODEM-M1-06-SP-05 CELLMODEM-M1-06-AT-05 - Includes COMMS-KIT-01 and CELLMODEM-M1-06-SP-05 with 5-year Sprint data plan for Ensemble sites- 4G based LTE-M1 cellular modem with 5-year Sprint data plan- 4G based LTE-M1 cellular modem with 5-year AT&T data planCircuit Breakers BRK-10A-2-240V BRK-15A-2-240V BRK-20A-2P-240V BRK-15A-2P-240V-B BRK-20A-2P-240V-B7YTTSVXW)EXSR&6&6&6&6&6&6ERH&6GMVGYMXFVIEOIVW Circuit breaker, 2 pole, 10A, Eaton BR210 Circuit breaker, 2 pole, 15A, Eaton BR215 Circuit breaker, 2 pole, 20A, Eaton BR220 Circuit breaker, 2 pole, 15A, Eaton BR215B with hold down kit support Circuit breaker, 2 pole, 20A, Eaton BR220B with hold down kit supportEPLC-01Power line carrier (communication bridge pair), quantity - one pairXA-SOLARSHIELD-ESReplacement solar shield for IQ Combiner 4/4C<%409+Accessory receptacle for Power Line Carrier in IQ Combiner 4/4C (required for EPLC-01)<%)2:4'&%Replacement IQ Gateway printed circuit board (PCB) for Combiner 4/4CX-IQ-NA-HD-125AHold down kit for Eaton circuit breaker with screws.ELECTRICAL SPECIFICATIONSRatingContinuous dutySystem voltage120/240 VAC, 60 HzEaton BR series busbar rating125 AMax. continuous current rating65 AMax. continuous current rating (input from PV/storage) 64 AMax. fuse/circuit rating (output)90 ABranch circuits (solar and/or storage)Up to four 2-pole Eaton BR series Distributed Generation (DG) breakers only (not included)Max. total branch circuit breaker rating (input)80A of distributed generation / 95A with IQ Gateway breaker includedProduction metering CT200 A solid core pre-installed and wired to IQ GatewayConsumption monitoring CT (CT-200-SPLIT)A pair of 200 A split core current transformers MECHANICAL DATADimensions (WxHxD)\\GQ ű\ű\ű ,IMKLXMW GQ [MXLQSYRXMRKFVEGOIXWWeightOK PFW Ambient temperature range -40º C to +46º C (-40º to 115º F)Cooling Natural convection, plus heat shieldEnclosure environmental rating3YXHSSV2680GIVXMƤIH2)1%X]TI6TSP]GEVFSREXIGSRWXVYGXMSRWire sizes • 20 A to 50 A breaker inputs: 14 to 4 AWG copper conductors• 60 A breaker branch input: 4 to 1/0 AWG copper conductors• Main lug combined output: 10 to 2/0 AWG copper conductors• Neutral and ground: 14 to 1/0 copper conductorsAlways follow local code requirements for conductor sizing.Altitude To 2000 meters (6,560 feet)INTERNET CONNECTION OPTIONSIntegrated Wi-Fi802.11b/g/nCellularCELLMODEM-M1-06-SP-05, CELLMODEM-M1-06-AT-05 (4G based LTE-M1 cellular modem). Note that an Enphase Mobile Connect cellular modem is required for all Ensemble installations.Ethernet3TXMSREP'EX) SV'EX 984)XLIVRIXGEFPI RSXMRGPYHIH COMPLIANCECompliance, IQ Combiner90'%2'7%'2S'*64EVX'PEWW&-')7Production metering: ANSI C12.20 accuracy class 0.5 (PV production)Consumption metering: accuracy class 2.5Compliance, IQ Gateway UL 60601-1/CANCSA 22.2 No. 61010-1 Enphase IQ Combiner 4/4CBy Toni Gindlesperger at 3:43 pm, Aug 30, 2022 TESLA.COM/ENERGYBackup Gateway 2POWERWALL660411149The Backup Gateway 2 for Tesla Powerwall provides energy management and monitoring for solar self-consumption, time-based control, and backup. The Backup Gateway 2 controls connection to the grid, automatically detecting outages and providing a seamless transition to backup power. When equipped with a main circuit breaker, the Backup Gateway 2 can be installed at the service entrance. When the optional internal panelboard is installed, the Backup Gateway 2 can also function as a load center. The Backup Gateway 2 communicates directly with Powerwall, allowing you to monitor energy use and manage backup energy reserves from any mobile device with the Tesla app. ENVIRONMENTAL SPECIFICATIONSOperating Temperature–20°C to 50°C (–4°F to 122°F)Operating Humidity (RH)Up to 100%, condensingMaximum Elevation3000 m (9843 ft) EnvironmentIndoor and outdoor ratedEnclosure TypeNEMA 3RPERFORMANCE SPECIFICATIONSAC Voltage (Nominal)120/240VFeed-In TypeSplit PhaseGrid Frequency60 HzCurrent Rating200 AMaximum Input Short Circuit Current10 kA1Overcurrent Protection Device100-200A; Service Entrance Rated1Overvoltage CategoryCategory IVAC MeterRevenue accurate (+/– 0.2 %)Primary ConnectivityEthernet, Wi-FiSecondary ConnectivityCellular (3G, LTE/4G)2User InterfaceTesla AppOperating ModesSupport for solar self-consumption, time-based control, and backupBackup TransitionAutomatic disconnect for seamless backupModularitySupports up to 10 AC-coupled PowerwallsOptional Internal Panelboard200A 6-space / 12 circuit Eaton BR Circuit BreakersWarranty10 yearsCOMPLIANCE INFORMATIONCertificationsUL 67, UL 869A, UL 916, UL 1741 PCS CSA 22.2 0.19, CSA 22.2 205EmissionsFCC Part 15, ICES 003NA 2020-05-231 When protected by Class J fuses, Backup Gateway 2 is suitable for use in circuits capable of delivering not more than 22kA symmetrical amperes.2 The customer is expected to provide internet connectivity for Backup Gateway 2; cellular should not be used as the primary mode of connectivity. Cellular connectivity subject to network operator service coverage and signal strength.MECHANICAL SPECIFICATIONSDimensions660 mm x 411 mm x 149 mm(26 in x 16 in x 6 in)Weight20.4 kg (45 lb)Mounting optionsWall mount, Semi-flush mountBy Toni Gindlesperger at 3:43 pm, Aug 30, 2022 TESLA.COM/ENERGYPOWERWALL                                                    RZQHUVWRTXLFNO\UHDOL]HWKHEHQH¿WVRIUHOLDEOHFOHDQSRZHUPERFORMANCE SPECIFICATIONSAC Voltage (Nominal)120/240 VFeed-In TypeSplit PhaseGrid Frequency60 HzTotal Energy14 kWhUsable Energy13.5 kWhReal Power, max continuous5 kW (charge and discharge)Real Power, peak (10s, off-grid/backup)7 kW (charge and discharge)Apparent Power, max continuous5.8 kVA (charge and discharge)Apparent Power, peak (10s, off-grid/backup)7.2 kVA (charge and discharge)Maximum Supply Fault Current10 kAMaximum Output Fault Current32 AOvercurrent Protection Device30 AImbalance for Split-Phase Loads100%Power Factor Output Range+/– 1.0 adjustablePower Factor Range (full-rated power)+/– 0.85Internal Battery DC Voltage50 VRound Trip Efficiency1,390%Warranty10 yearsENVIRONMENTAL SPECIFICATIONSOperating Temperature–20°C to 50°C (–4°F to 122°F)Recommended Temperature0°C to 30°C (32°F to 86°F)Operating Humidity (RH)Up to 100%, condensingStorage Conditions–20°C to 30°C (–4°F to 86°F)Up to 95% RH, non-condensingState of Energy (SoE): 25% initialMaximum Elevation3000 m (9843 ft) EnvironmentIndoor and outdoor ratedEnclosure TypeNEMA 3RIngress RatingIP67 (Battery & Power Electronics) IP56 (Wiring Compartment)Wet Location RatingYesNoise Level @ 1m< 40 dBA at 30°C (86°F)MECHANICAL SPECIFICATIONSDimensions11150 mm x 755 mm x 147 mm (45.3 in x 29.6 in x 5.75 in)Weight1114 kg (251.3 lbs)Mounting optionsFloor or wall mount 1Dimensions and weight differ slightly if manufactured before March 2019. 1Values provided for 25°C (77°F), 3.3 kW charge/discharge power.2In Backup mode, grid charge power is limited to 3.3 kW.3AC to battery to AC, at beginning of life.COMPLIANCE INFORMATIONCertificationsUL 1642, UL 1741, UL 1973, UL 9540, IEEE 1547, UN 38.3Grid ConnectionWorldwide CompatibilityEmissionsFCC Part 15 Class B, ICES 003EnvironmentalRoHS Directive 2011/65/EUSeismicAC156, IEEE 693-2005 (high)753 mm (29.6 in)147 mm (5.75 in)1150 mm (45.3 in)Contact Tesla for additional information.TESLA.COM/ENERGYTYPICAL SYSTEM LAYOUTS        Main panelSub panelSolarHome loadsSolar inverterUtility meter GridBackup GatewayPowerwallBackup loadsOptionalNA - BACKUP - 2019-06-11Utility meterGridBackup Gatewayincludingservice disconnectMain panelSolarWhole homebackupSolar inverterPowerwallOptionalBy Toni Gindlesperger at 3:43 pm, Aug 30, 2022 Tech BriefSolar Is Not Always SunnyOver their lifetime, solar panels experience countless extreme weather events. Not just the worst storms in years, but the worst storms in 40 years. High winds capable of ripping panels from a roof, and snowfalls weighing enough to buckle a panel frame. XR Rails are the structural backbone preventing these results. They resist uplift, protect DJDLQVWEXFNOLQJDQGVDIHO\DQGHIÀFLHQWO\transfer loads into the building structure. Their superior spanning capability requires fewer roof attachments, reducing the number of roof penetrations and the amount of installation time.XR Rail FamilyForce-Stabilizing CurveSloped roofs generate both vertical and lateral forces on mounting rails which can cause them to bend and twist. The curved shape of XR Rails is specially designed to increase strength in both directions while resisting the twisting. This unique feature ensures greater security during extreme weather and a longer system lifetime.Compatible with Flat & Pitched RoofsRoof Mount utilizes XR Rails, along with optional all-in-one attachments, WRVHFXUHV\VWHPVÁXVKagainst residential roofs.Roof Mount utilizes XRRails, along with optionalall-in-one attachments,WRVHFXUHV\VWHPVÁXVKagainst residential roofs.Corrosion-Resistant MaterialsXR Rails are compatible with FlashFoot and other pitched roof attachments.IronRidge offers a range of tilt leg RSWLRQVIRUÁDWroof mounting applications.All XR Rails are made of 6000-series aluminum alloy, then protected with an DQRGL]HGÀQLVK$QRGL]LQJSUHYHQWVVXUIDFHand structural corrosion, while also providing a more attractive appearance. XR Rail Family7KH;55DLO)DPLO\RIIHUVWKHVWUHQJWKRIDFXUYHGUDLOLQWKUHHWDUJHWHGVL]HV(DFKVL]HVXSSRUWVVSHFLÀFdesign loads, while minimizing material costs. Depending on your location, there is an XR Rail to match. © 2020 IronRidge, Inc. All rights reserved. Visit www.ironridge.com or call 1-800-227-9523 for more information. Version 1.20Tech BriefRail SelectionThe table below was prepared in compliance with applicable engineering codes and standards.* Values are based on the following criteria: ASCE 7-16, Gable Roof Flush Mount, Roof Zones 1 & 2e, Exposure B, Roof 6ORSHRIWRGHJUHHVDQG0HDQ%XLOGLQJ+HLJKWRIIW9LVLW,URQ5LGJHFRPIRUGHWDLOHGFHUWLÀFDWLRQOHWWHUVLoadRail SpanSnow (PSF) Wind (MPH) 4’5’ 4”6’8’10’12’None90120140XR10XR100XR100016020901201401603090160409016080160120160XR100XR100 is the ultimate residential mounting rail. It supports a range of wind and snow conditions, while also maximizing spans up to 10 feet.• ·VSDQQLQJFDSDELOLW\• Heavy load capability• &OHDU EODFNDQRGL]HGÀQLVK• Internal splices availableXR10;5LVDVOHHNORZSURÀOHPRXQWLQJrail, designed for regions with light or no snow. It achieves spans up to 6 feet, while remaining light and economical.• ·VSDQQLQJFDSDELOLW\• Moderate load capability• &OHDU EODFNDQRGL]HGÀQLVK• Internal splices availableXR1000XR1000 is a heavyweight among VRODUPRXQWLQJUDLOV,W·VEXLOWWRKDQGOHextreme climates and spans up to 12 feet for commercial applications.• ·VSDQQLQJFDSDELOLW\• Extreme load capability• &OHDUDQRGL]HGÀQLVK• Internal splices available;HISLPZTLHU[[VILHZPTWSPÄLKZWHUJOHY[MVYJVU]L`PUNNLULYHSYHPSJHWHIPSP[PLZ<ZLHWWYV]LKJLY[PÄJH[PVUSL[[LYZMVYHJ[\HSKLZPNUN\PKHUJLBy Toni Gindlesperger at 3:42 pm, Aug 30, 2022 GODWIN ENGINEERING AND DESIGN, LLC 8378 Foxtail Loop, Pensacola, FL 32526 | (850)712-4219 | chad@godwineng.com July 15, 2022 To: City of Atlantic Beach Zoning Department 800 Seminole Rd Atlantic Beach, FL 32233 Re: Siefken – Residential PV Roof Mount Installation 156 Seminole Road Atlantic Beach, FL 32233 Plan Reviewer, This letter is regarding the installation of a new roof mounted Solar PV System on the existing residential structure at the address above. I have reviewed the attachment plan and have determined that the roof mounted PV system is in compliance with the applicable sections of the following Codes as amended and adopted by the jurisdiction: 2020 Florida Building Code 7th Edition, FBC ASCE 7 Min. Design Loads for Buildings & Other Structures Per 2020 FBC, the Roof Mounted PV system will be subject to the following design criteria: Design Wind Speed (Vult) - 130mph 3sec gust, Exposure Category – C The PV System consist of the modules, railing, and connection hardware. The system will add a dead load of approximately 3 psf to the roof. The existing roof covering is EPDM with min. ½” plywood decking and 2” x 6” roof trusses 16” O.C. The roofing, decking, and roof trusses are in good condition. The existing structure will be adequate for supporting the additional PV dead load and wind loads. The securement method of the PV system is to be flush mounted to the EPDM roof with the Iron Ridge railing and Roof Tech Minis. The attachments can be attached up to 48” apart in roof zones 1’ & 1 and 32’’ apart in the roof zone 2 and 16’’ apart in the roof zone 3. The mounts should be staggered, where possible, to allow distribution of the design loads evenly to the structure. The mounts shall be installed 2 x M5 x 60mm stainless steel Lag bolts. with minimum 2-5/16” thread length directly to roof truss. Please see attached documents and contact me should you have any questions. Sincerely, D. Chad Godwin, PE 81360 Exp. 02/28/2023 Donnie C Godwin 2022.08. 19 10:02:42 '00'05- By Toni Gindlesperger at 3:42 pm, Aug 30, 2022 Risk Category II Table 1.5-1 Wind Speed (asd)101 mph FRC R301.2.1.3 Basic Wind Speed (Ult)130 mph Figure 26.5-1B Effective Wind Area 23.40 ft2 26.20 Roof Angle Wind Directionality Kd 0.85 Table 26.6-1 Roof Type Flat Topographic factor Kzt 1.00 26.8 or 26.8.2 Exposure Cat. B,C, or D C Section 26.7 Ground Elevation Factor Ke 1.00 Table 26.9-1 Mean Roof Height h 15.00 ft Velocity Exposure Coefficient Kz 0.85 Table 26.10-1 Roof attachment Array Edge Factor gE 1.50 29.4.4 *Modules are considered Exposed Rafter/Truss Spacing 16 in O.C.Solar Panel Equalization Factor ga 0.65 Fig. 29.4-8 No. of Rails 2 Velocity Pressure qh 18.75 psf qh=0.00256 KzKztKdKeV2 No. of Modules - Portrait 18 Added Safety Factor 1.2 No. of Modules - Landscape 0 Allowable Pullout per mount 569.0 lbs Module Model Number 0.4h or 0.6h 9.00 ft Flat - 0.6h, Gable, Hip - 0.4h bldg. least horizontal dim (typ.)360 in 10% of least horizontal dim 3.00 ft Elevation <1000 ft Roof Zone Set Back a 9.00 ft Est. # of attachment points 36 h2 5 in Not > 10in(panel height above roof) 2h2 10 in *min distance array shall be from the roof edge, Gable Ridge, or hip ridge 18 0.25 in min gap between all panels but not > 6.7ft Wmod 52 lbs 3.41 ft d1 1.00 ft Horizontal distance orthogonal to panel edge Wmods 932 lbs 6.87 ft d2 0.25 ft Horizontal distance from edge of one panel to the nearest edge in the next row Wmic 72 lbs 23.40 ft2 0.5h 7.50 ft *modules are considered exposed that are within 1.5Lp from roof edge WPV rail 13 lbs Wtotal 1018 lbs Ultimate Allowable AT 421.17 ft2 113.4 75.6 Eq.1 Point Load = Roof Zone psf * Aeff DPV 2.42 psf -75.6 -50.4 Eq.2 Aeff = (Module Length /2) * Max Span Weight/attachment 28.3 lbs Eq.3 *Max span Equation, SF = Allowable pullout / Point Load Eq.4 Max Span = Allowable Pullout / (SF * Roof Zone psf * L/2) 1' 1 2 3 0 0 a) GCp - Uplift -0.9 -1.7 -2.3 -3.2 #N/A #N/A GCp - Down 0.3 0.3 0.3 0.3 #N/A #N/A b)Allowable Module load ratings are determined by SF = 1.5 p = qh(GCp)(gE)(γa)-14.1 -28.8 -39.8 -56.3 #N/A #N/A psf 29.4-7 p = qh(GCp)(gE)(γa)5.5 5.5 5.5 5.5 #N/A #N/A psf 29.4-7 Max Allowable Span 5.33 4 2.67 1.33 #N/A #N/A ft *notes Max Cantilever (in)22 16 11 6 #N/A #N/A Max span * 33% (in) ASCE 7-16 CHAPTER 29 WIND LOADS - Rooftop Solar Panels Minimum Design Loads - Part 1: Enclosed(Gable,Hip,Flat h<60ft, 0°<θ<45°) Notes PV Attachment - Results Total Weight Total Area Dead Load Array Width Micro/optimizer Length PV Rail Module Area PV Dead Load Module and Racking Specs # of Modules The Max span between attachment points must not exceed the rail spans provided by racking manufacture. Wind Load Paramaters 0° to 7° SP4xxM-72HB Roof Zones - Flat 0° to 7° 10% of least hor. Dim. Or 0.4h, whichever is smaller, but not less than either 4% of Least hor. Or 3ft. (flat roof - 0.6h) Module Dimensions, LxWxH (in) Load Rating - Snow(psf) Load Rating - Wind(psf) Wind Load Parameters - Inputs RT-Mini 60mm to Rafter 82.44 x 40.87 x 1.57 Module load ratings Donnie C Godwin 2022.08. 19 10:03:02 '00'05- By Toni Gindlesperger at 3:42 pm, Aug 30, 2022