ABC 5V Crimp Manual September_2019Technical/Installation Information 5V CRIMP IMPORTANT NOTICE READ THIS MANUAL OCMPLETELY PRIOR TO BEGINNING THE INSTALLATION OF THE 5V CRIMP PANEL SYSTEM. ALWAYS INSPECT EACH AND EVERY PANEL AND ALL ACCESSORIES BEFORE INSTALLATION. NEVER INSTALL ANY PRODUCT IF ITS QUALITY IS IN QUESTION. NOTIFY ABC IMMEDIATELY IF ANY PRODUCT IS BELIEVED TO BE OUT OF TOLERANCE, SPECIFICATION OR HAS BEEN DAMAGED DURING SHIPMENT. IF THERE IS A CONFLICT BETWEEN PROJECT ERECTION DRAWINGS PROVIDED OR APPROVED BY THE MANUFACTURER AND DETAILS IN THIS MANUAL, PROJECT ERECTION DRAWINGS WILL TAKE PRECEDENCE. Descriptions and specifications contained herein were in effect at the time this publication was approved for printing. In a continuing effort to refine and improve products, ABC reserves the right to discontinue products at any time or change specifications and/or designs without incurring obligation. To ensure you have the latest information available, please inquire or visit our website at www.abcmetalroofing.com. Application details are for illustration purposes only and may not be appropriate for all environmental conditions, building designs, or panel profiles. Projects should be engineered to conform to applicable building codes, regulations, and accepted industry practices. Insulation is not shown in these details for clarity. For complete performace specifications, product limitations, and disclaimers, please consult ABC's Paint and Galvalume Plus® warranties. Upon receipt of payment in full, these warranties are availalbe upon request for all painted or Galvalume Plus® prime products. Sample copies can be found at www.abcmetalroofing.com or contact your local ABC Sales Representative. ©Copyright Cornerstone Building Brands 2019 All Rights Reserved The Engineering data contained herein is for the expressed use of customers and design professionals. Along with this data, it is recommended that the design professional have a copy of the most current version of the North American Specification for the Design of Cold-Formed Steel Structural Members published by the American Iron and Steel Institute to facilitate design. This Specification contains the design criteria for cold-formed steel components. Along with the Specification, the designer should reference the most current building code applicable to the project jobsite in order to determine environmental loads. If further information or guidance regarding cold-formed design practices is desired, please contact the manufacturer. 5V Crimp TABLE OF CONTENTS PRODUCT INFORMATION Application, Storage and Handling Information .................................V-4 - V-5 Architect/Engineer Information...................................................V-6 General Description ...........................................................V-7 UL 90 Construction Numbers....................................................V-8 Section Properties ............................................................V-9 Product Checklist ............................................................V-10 Fastener Patterns............................................................V-11 DETAILS Ridge ....................................................................V-12 Endlap ....................................................................V-13 Valley ....................................................................V-14 Hip ....................................................................V-15 Rake ....................................................................V-16 Eave ....................................................................V-17 Gutter ....................................................................V-18 Slope Change...............................................................V-19 PRODUCT INFORMATION 5V Crimp V-4 REV 00.02 SEE www.abcmetalroofing.com FOR CURRENT INFORMATION SUBJECT TO CHANGE WITHOUT NOTICE APPLICATION, STORAGE AND HANDLING INFORMATION SAFETY PRECAUTIONS Improper unloading and handling of bundles and crates may cause bodily injury or material damage. Use extreme care in the operation of power lifting devices such as cranes and forklifts and follow the safety instructions provided by their manufacturer. Crates, boxes and bundles may be bulky, heavy, or both. The improper or unaided lifting of them may cause bodily injury. The manufacturer is not responsible for bodily injuries or material damage due to improper handling during unloading, storage, or job site placement. Protective heavy duty gloves should be worn when handling metal panels and trim products. Safety goggles or face shield should be worn while cutting or drilling metal products with power tools. Follow the safety instructions provided by the manufacturer of the power tools. Use extreme care when walking, sitting, standing, or kneeling on a metal roof to avoid a fall. Galvalume® and galvanized panels have a light coating of oil to protect the panels from moisture prior to erection. They can be extremely slippery, as are painted panels, when they are wet. If necessary, remove the oil coating with a non-abrasive detergent and water mixture followed by a clear water rinse. Insure the panels are dry prior to installation. STORAGE AND HANDLING To preserve and protect the attractive appearance of ABC's roofing and siding from damage caused by moisture, corrosive chemicals or improper handling, it is necessary that you take a few simple precautions. When material is received bundled, panels should be inspected for moisture. If there is moisture, the panels should be separated and dried. If shipping damage is found, the carrier should be advised and a notation made on the bill of lading. On job sites, reasonable care should be taken when handling painted surfaces during installation in order to protect the finish. Although the paint coating is tough and provides impact resistance, dragging panels across the surface of one another will almost certainly mar the finish. Prolonged storage of sheets in bundles is not recommended. If conditions do not permit immediate erection, extra care must be taken to protect the material from damage caused by moisture. Store bundled sheets ONLY IN A DRY PLACE. Sheets should be unbundled, stood on end against an interior wall to allow for air circulation. If unable to store sheets in an upright position, strapping bands should be broken and sheets should be blocked off the floor with one end slightly elevated. Stacked sheets should then be completely protected from the elements while maintaining good airflow to prevent condensation. A properly draped canvas tarpaulin, that allows air flow, is an example of a good protective cover. Do not use plastic as it causes sweating or condensation to occur. BUILDING DESIGN AND CONSTRUCTION It is important to protect metal panels from potentially corrosive situations and materials. This will insure the good performance and long life of the metal. If installing metal panels over green lumber, damp lumber, or treated lumber (CCA or ACQ), a barrier must be installed to separate the wood from the metal. A barrier may be formed with plastic or other suitable material. Avoid contact with, or water runoff from, dissimilar metals such as copper, lead or graphite. Dissimilar metals under the roof panels may be separated with asphalt, builders felt, caulking compounds or gasket material. Metal panels must further be protected from contact with strong chemicals such as fertilizers, lime acids, animal waste and soil. All of these have the potential to initiate corrosion in metal panels. Metal panels should not be in permanent contact with soil. Temperature variations, (dew point) between the outside air and the interior building air mass can cause condensation to occur on the inside of the building on the panel's surfaces. Proper venting and air flow consideration and the use of a vapor barrier such as vinyl backed insulation can eliminate this problem. If left unattended, condensation can cause the premature degradation of the metal and void any applicable warranties. For information on this subject, please refer to MCA's white paper on controlling condensation in steep slope metal roofing systems. The substructure, on which the panels are to be installed, must be “on plane” (1/4" tolerance) from eave to ridge. Maximum recommended panel length is 36'; minimum panel length is 3'. PRODUCT INFORMATION 5V Crimp SUBJECT TO CHANGE WITHOUT NOTICE SEE www.abcmetalroofing.com FOR CURRENT INFORMATION REV 00.02 V-5 APPLICATION, STORAGE AND HANDLING INFORMATION VENTILATIONSufficient air movement should be provided by means of a ridge or rotary vent, power operated fans, or other openings to minimize condensation. Contact the equipment manufacturer for specific information or a qualified mechanical engineer. ROOFING INSTALLATION Check substructure for proper alignment and uniformity to avoid panel distortion. ABC recommends the use of 5/8" plywood for the substructure. Minimum 5/8" plywood substructure is MANDATORY for UL 90 Uplift Rating. THE MINIMUM roof slope recommended is 3 inches of rise per foot. This ensures that sufficient slope is present for adequate drainage. The panels must be installed over a completely water-proofed substructure. It is important to remember that in the installation of roof sheets, the sidelaps should face away from the direction of the prevailing wind. The first sheet should be installed square with the eave and at the down-wind end of the roof, farthest from the direction of the wind. For proper fastener application, refer to our published guide. Remember to sweep the roof clean of any metal filings created from fastener placement or cutting of panels to prevent rust marks on the surface of the painted panels. Installing Slimline® panels over an uneven substrate will cause distortion of the panel. It is the responsibility of the installer to insure a suitable substrate prior to panel application. Distortion in the panel caused by an uneven substrate, ripples or laps in the vapor barrier, debris, etc., are not defects in the material, and are not the responsibility of ABC. Slimline® panels cannot be endlapped. CLOSURES AND SEALANTS To thoroughly protect the contents of any structure from moisture, regardless of building size or roof slope, closure strips should be used at the roof ridge, hip and eave. For maximum protection, all caulking used should be urethane. Silicone caulks are not recommended for panels or trims. CUTTING METAL PANELS ABC recommends the use of power shears or nibblers that can follow the contour of the panel’s profile. While not recommended, If a power saw is to be used, you must use a blade designed to cut the metal at a low temperature to prevent melting of the Galvalume® coating, such as the Slasher® from Dynamic Fasteners. You should protect the panel during the cutting process to prevent marring the panel surface. Panels should be thoroughly brushed after cutting to remove any particles of metal and caution should be taken that filings from cutting don’t settle on other panels. Follow the safety instructions provided by the manufacturer when using any tools. PANEL SELECTIONABC’s bare Galvalume® (Galvalume Plus®), and color coated products are produced from material that meets or exceeds the specifications outlined in ASTM-792. If you chose a bare Galvalume® (Galvalume Plus®), for your application you should be aware that this product is recommended for applications where aesthetic appearance is not your prime concern. Unpainted products may not weather uniformly and while they may be shiny and bright when new, they will fade or “patina” with age. Acid rain and other corrosive atmospheres, as well as the accumulation of airborne debris and dirt will affect this aging process and the products’ appearance. If aesthetic appearance is one of your concerns, ABC recommends you choose one of our many color coated panel selections. Copies of ABC’s color coated panel warranty are available at your point of purchase, or from the ABC office located nearest to you. PRODUCT INFORMATION 5V Crimp V-6 REV 00.02 SEE www.abcmetalroofing.com FOR CURRENT INFORMATION SUBJECT TO CHANGE WITHOUT NOTICE ARCHITECT/ENGINEER INFORMATION 1. Minimum recommended slope is 3:12. For slopes less than 3:12, call ABC. 2. Use a properly aligned and uniform substructure to avoid panel distortion. Typical substructure - B\," plywood; alternate substructure metal or wood stringers. Spacing of stringers to be determined by load tables. For illus-tration purposes, details are shown over plywood. 3. 5V Crimp panels are water shedding panels and therefore must be installed on a minimum 3:12 roof slope. The panels must be installed over a completely waterproofed substructure. If the waterproof membrane is mechani-cally attached with metal fasteners of any type, fasteners should be covered to protect the back side of the roof panels. Any mechanical attachment device that does not lay flat on the deck will telegraph through the panels. 4. Panels are subject to surface distortion due to improperly applied fasteners. Overdriven fasteners will cause stress and induce oil canning across the panel at or near the point of attachment. Oil canning is not a cause for rejection. 5. For proper fastener application, see Product Checklist. 6. For continuous panels over 25', please inquire. Panels may be endlapped. 7. All panel ends must be sealed at eave and valley conditions. Refer to Pages V-11, V-14 and V-15 for end seal-ant details. 8. Fastener spacings across the width of the panel are shown on Page V-7. For fastener spacings along the length of the panel, use the wind load table on Page V-5 in conjunction with the governing code. CAUTION Most of the 5V Crimp load tables indicate panels can obtain a 20# live load on 2'-6" centers when installed over stringers. Please keep in mind these are uniform live loads and will not support a 200 pound man standing on one square foot. From an erectability and industry standard point of view, it is recommended that you should not span the panels more than 2'-6". PRODUCT INFORMATION 5V Crimp SUBJECT TO CHANGE WITHOUT NOTICE SEE www.abcmetalroofing.com FOR CURRENT INFORMATION REV 00.02 V-7 GENERAL DESCRIPTION PRODUCT SELECTION CHART 12" 24"Z\x" Coverage Width - 24" Minimum Slope - 3:12 Panel Attachment - Wood screws Panel Substrate - Galvalume Plus® Gauges - 32, 29 or 26 Finishes - Smooth or Embossed Coating - Galvalume Plus®, Signature 200® (Siliconized Polyester), G-40 Galvanized l - Available in any quantity. n - Minimum quantity may be required. Product Galvalume Plus Galvalume Plus Signature 200 5V Crimp 29 26 26 24" Wide l l l PRODUCT INFORMATION 5V Crimp V-8 REV 00.02 SEE www.abcmetalroofing.com FOR CURRENT INFORMATION SUBJECT TO CHANGE WITHOUT NOTICE UL 90 Requirements 5V Crimp Construction # 453 1. Metal Panels (26 gauge) – 24"wide, continuous over two or more spans. 2. Fastener spacing along the length of the panel is 3 feet on center. 3. Fasteners – No.14-10 x 1Z\x" Type A, Hex Head with separate B\, in. O.D. steel washer and a bonded neoprene washer. Fastener spacing is as follows: a line of fasteners is to be installed adjacent to the double "V" in the middle of the panel for a total of four fasteners across the width of the panel. Fastener spacing along the length of the panel is 3 feet on center. FIRE RESISTANCE RATING The panel qualifies for a Class A fire rating when installed over a non-combustible substrate in compliance with Underwriters Laboratories Standard UL-263. Panels installed over combustible substrate will qualify for a Class C Fire Rating only. IMPACT RESISTANCE The 5V panels carry a Class 4 rating under UL-2218 "Test Standard For Impact Resistance". For UL 90 Rated Roofs, the above requirements must be followed. See UL Roofing Materials and Systems Directory for additional requirements. If you have any questions, call ABC before proceeding. State of Florida Approval Numbers: FL#11903.1 Miami Dade County NOA: 11-0810.10, see special installation instructions, www.miamidade.gov. PRODUCT INFORMATION 5V Crimp SUBJECT TO CHANGE WITHOUT NOTICE SEE www.abcmetalroofing.com FOR CURRENT INFORMATION REV 00.02 V-9 12" 24"Z\x" 5V CRIMP 24" Coverage PANEL Fy WEIGHT Ixe Sxe Maxo Ixe Sxe Maxo GAUGE (KSI)(PSF) (IN.4/FT.) (IN.3/FT.) (KIP-IN.) (IN.4/FT.) (IN.3/FT.) (KIP-IN.) 29 60 *0.60 0.0011 0.0045 0.161 0.0022 0.0060 0.285 26 60 *0.95 0.0016 0.0063 0.225 0.0030 0.0081 0.386 * Fy is 80-ksi reduced to 60-ksi in accordance with the 2012 edition of the North American Specification For Design Of Cold-Formed Steel Structural Members - A2.3.2. NOTES: 2. Ixe is for deflection determination. 3. Sxe is for bending. 4. Maxo is allowable bending moment. 5. All values are for one foot of panel width. SECTION PROPERTIES NEGATIVE BENDING POSITIVE BENDING 1. All calculations for the properties of 5V Crimp panels are calculated in accordance with the 2012 edition of the North American Specification For Design Of Cold-Formed Steel Structural Members. 29 Gauge (0.0133"), Fy = 60 ksi, Fu = 61.5 ksiSPAN TYPE 1.0 1.5 2.0 2.5 3.0 3.5 4.0NEGATIVE WIND LOAD 107.04 47.57 26.76 17.13 11.89 8.74 6.41LIVE LOAD/DEFLECTION 130.26 57.28 24.17 12.37 7.16 4.51 3.02NEGATIVE WIND LOAD 162.81 78.38 45.49 29.56 20.70 15.29 11.74LIVE LOAD/DEFLECTION 101.37 46.40 26.38 16.97 11.82 8.70 6.67 NEGATIVE WIND LOAD 167.25 74.33 41.81 26.76 18.58 13.65 10.45LIVE LOAD/DEFLECTION 123.94 57.39 32.78 21.13 13.61 8.57 5.74NEGATIVE WIND LOAD 173.39 77.06 43.35 27.74 19.27 14.15 10.84LIVE LOAD/DEFLECTION 116.57 53.77 30.66 19.75 13.76 9.10 6.09 26 Gauge (0.0181"), Fy = 60 ksi, Fu = 61.5 ksiSPANTYPE 1.0 1.5 2.0 2.5 3.0 3.5 4.0NEGATIVE WIND LOAD 150.26 66.78 37.57 24.04 16.70 12.27 9.39 LIVE LOAD/DEFLECTION 224.74 77.61 32.74 16.76 9.70 6.11 4.09NEGATIVE WIND LOAD 220.22 106.12 61.62 40.05 28.05 20.72 15.91LIVE LOAD/DEFLECTION 141.66 65.00 36.99 23.80 16.58 12.20 9.35NEGATIVE WIND LOAD 234.79 104.35 58.70 37.57 26.09 19.17 14.67LIVE LOAD/DEFLECTION 172.89 80.32 45.93 29.63 18.33 11.54 7.73 NEGATIVE WIND LOAD 243.40 108.18 60.85 38.94 27.04 19.87 15.21LIVE LOAD/DEFLECTION 162.72 75.27 42.97 27.70 19.31 12.25 8.21 Notes: 1. Strength calculations based on the 2012 AISI Standard "North American Specification for the Design o Cold-formed Steel Structural Members."2. Allowable loads are applicable for uniform loading and spans without overhangs3. LIVE LOAD/DEFLECTION load capacities are for those loads that push the panel against its supports. The applicable limit states are flexure, shear, combined shear and flexure, web crippling at end and interio supports, and a deflection limit of L/180 under strenght-level loads4. NEGATIVE WIND LOAD capacities are for those loads that pull the panel away from its supports. The applicable limit states are flexure, shear, combined shear and flexure, and a deflection limit of L/60 under 10-year wind loading.5. Panel pullover and Screw pullout capacity must be checked separately using the screws employed fo each particular application when utilizing this load chart6. Effective yield strength has been determined in accordance with section A2.3.2 of the 2012 NAS specification. 7. The use of any accessories other than those provided by the manufacturer may damage panels, void all warranties and will void all engineering data 8. This material is subject to change without notice. Please contact MBCI for most current data SPAN IN FEET 1-span 2-span 3-span The Engineering data contained herein is for the expressed use of customers and design professionals. Along with this data, it is recommended that the design professional have a copy of the most current version of the North American Specification for the Design of Cold-Formed Steel Structural Members published by the American Iron and Steel Institute to facilitate design. This Specification contains the design criteria for cold-formed steel components. Along with the Specification, the designer should reference the most current building code applicable to the project jobsite in order to determine environmental loads. If further information or guidance regarding cold-formed design practices is desired, please contact the manufacturer. 4-span LOAD TYPE LOAD TYPE SPAN IN FEET 1-span 2-span 3-span 4-span Notes:1. Strength calculations based on the 2012 AISI Standard "North American Specification for the Design of Cold-formed Steel Structural Members."2. Allowable loads are applicable for uniform loading and spans without overhangs. 3. LIVE LOAD/DEFLECTION load capacities are for those loads that push the panel against its supports. The applicable limit states are flexure, shear, combined shear and flexure, web crippling at end and interior supports, and a deflection limit of L/180 under strenght-level loads.4. NEGATIVE WIND LOAD capacities are for those loads that pull the panel away from its supports. The applicable limit states are flexure, shear, combined shear and flexure, and a deflection limit of L/60 under 10-year wind loading.5. Panel pullover and Screw pullout capacity must be checked separately using the screws employed for each particular application when utilizing this load chart.6. Effective yield strength has been determined in accordance with section A2.3.2 of the 2012 NAS specification. 7. The use of any accessories other than those provided by the manufacturer may damage panels, void all warranties and will void all engineering data.8. This material is subject to change without notice. Please contact ABC for most current data. The Engineering data contained herein is for the expressed use of customers and design professionals. Along with this data, it is recommended that the design professional have a copy of the most current version of the North American Specification for the Design of Cold-Formed Steel Structural Members published by the American Iron and Steel Institute to facilitate design. This Specification contains the design criteria for cold-formed steel components. Along with the Specification, the designer should reference the most current building code applicable to the project jobsite in order to determine environmental loads. If further information or guidance regarding cold-formed design practices is desired, please contact the manufacturer. Notes:1. All calculations for the properties of 5V Crimp panels are calculated in accordance with the 2012 edition of the North American Specification for the Design of Cold-Formed Steel Structural Members.2. Ixe is for deflection determination. 3. Sxe is for bending.4. Maxo is allowable bending moment.5. All values are for one foot of panel width. ALLOWABLE UNIFORM LOADS IN POUNDS PER SQUARE FOOT DETAILS 5V Crimp V-10 REV 00.02 SEE www.abcmetalroofing.com FOR CURRENT INFORMATION SUBJECT TO CHANGE WITHOUT NOTICE PRODUCT CHECKLIST 5V Crimp Panel Rake Trim Eave Trim Zee Closure Outside Closure Tri-Bead Tape Sealer Inside Closure Triple Bead Tape Sealer Ridge/Hip Box Gutter 12"24"Z\x"6" SPECIFY ANGLE COLOR 6" 2 Z\x" 1"B\,"3"B\,"COLOR 3 Z\x" 3" B\," SPECIFYANGLE COLOR 3" B\," COLOR 90° 4" 1Z\x" C\v" 1" 1"135ºZ\x" COLOR 3" B\," COLOR 90° 4" 1Z\x" 3Z\,"4" 4"COLOR 1"B\," 3Z\x" SPECIFY ANGLE 105° 105° SPECIFY ANGLE 9⁄"45° ⁄" 9⁄" COLOR ⁄"20³⁄"20³⁄" SPECIFY ANGLE COLOR Standard - Forvalley runs under 30' Extended - Forvalley runs over 30'q q q q q AG-202 q AG-279 q HW-452 q HW-504 q AG-242 qAG-250 q AG-246 q FL-338q White HW-540qAG-274q AG-292 q Specify Roof Pitch Specify Roof Pitch Specify Roof Pitch Valley AG-296 q HW-450 q HW-502 q Drip Edge Continuous Cleat Urethane Tube Sealant Fastener #910 x 1Z\x" Long Life Wood Fastener Fastener #13 10 x 1" Pancake Head Fastener #414 x M\," Long LifeLap Tek Fastener #14 Z\, x C\zn" Pop Rivet Stainless Steel DETAILS 5V Crimp SUBJECT TO CHANGE WITHOUT NOTICE SEE www.abcmetalroofing.com FOR CURRENT INFORMATION REV 00.02 V-11 FASTENER PATTERN AT EAVE AND ENDLAP SUBSTRUCTURE 5V CRIMP PANEL WATERPROOF MEMBRANE FASTENER #9 FASTENER PATTERN AT INTERIOR OF PANEL SUBSTRUCTURE 5V CRIMP PANEL FASTENER #9 ALTERNATE FASTENER PATTERN SUBSTRUCTURE 5V CRIMP PANEL FASTENER #9 WATERPROOF MEMBRANE WATERPROOF MEMBRANE FASTENER PATTERNS DETAILS 5V Crimp V-12 REV 00.02 SEE www.abcmetalroofing.com FOR CURRENT INFORMATION SUBJECT TO CHANGE WITHOUT NOTICE TYPICAL DETAILS RIDGE CROSS SECTION OF RIDGE OVER WOOD DECK WATERPROOF MEMBRANE (NOT BY MBCI) WATERPROOF MEMBRANE (NOT BY MBCI) 5V CRIMP PANEL ⁄" PLYWOOD MINIMUM(NOT BY MBCI) ⁄" PLYWOOD MINIMUM (NOT BY MBCI) TRI-BEAD TAPE SEALER (HW-504) TOP ANDBOTTOM OF CLOSURE TRI-BEAD TAPE SEALER (HW-504) TOP ANDBOTTOM OF CLOSURE OUTSIDE CLOSURE(HW-452) RIDGE FLASH(AG-202) RIDGE FLASH(AG-202) OUTSIDE CLOSURE(HW-452) 5V CRIMP PANEL 10 x 1¹⁄" LONG LIFE WOOD FASTENER @ 1'-0" O.C.(FASTENER #9) 10 x 1¹⁄" LONG LIFE WOOD FASTENER @ 1'-0" O.C.(FASTENER #9) ISOMETRIC VIEW OF RIDGE OVER WOOD DECK NOTE:1. Stop panels 2" from center line of ridge.2. Install first row of fasteners across panel to substrate 1'-0" down from bottom edge of ridge trim and space 1'-0" O.C.3. Install Tri-Bead tape sealer across width of panels. Top edge of tape sealer is 1C\v" from top edge of panel. Install outside closures on top of Tri-Bead tape sealer. Install additional run of tape sealer on top of outside closure.4. Attach ridge flash with Fastener #9 (10 x 1Z\x" Long Life Wood Fastener)1'-0" O.C. Install fasteners at each "V" in the panel to avoid dimpling the ridge flash. DETAILS 5V Crimp SUBJECT TO CHANGE WITHOUT NOTICE SEE www.abcmetalroofing.com FOR CURRENT INFORMATION REV 00.02 V-13 TYPICAL DETAILS ENDLAP CROSS SECTION OF ENDLAP OVER WOOD DECK 5V CRIMP PANEL 6 "L A P 2 " 5V CRIMP PANEL ISOMETRIC VIEW OF ENDLAP OVER WOOD DECK 10 x 1¹⁄" LONG LIFE WOOD FASTENER (4) PER PANEL(FASTENER #9) 10 x 1¹⁄" LONG LIFE WOOD FASTENER (4) PER PANEL (FASTENER #9) ⁄" PLYWOOD MINIMUM (NOT BY MBCI) ⁄" PLYWOOD MINIMUM (NOT BY MBCI) TRI-BEAD TAPE SEALER (HW-504) TRI-BEAD TAPE SEALER (HW-504) WATERPROOF MEMBRANE (NOT BY MBCI) WATERPROOF MEMBRANE (NOT BY MBCI) NOTE:1. Panel endlap is 6".2. Install Tri-Bead tape sealer across width of bottom panel before installation of top panel. Top edge of tape sealer is 4C\v" from uplsope end of bottom panel. 3. Fastener pattern at endlap is shown on page V-7. DETAILS 5V Crimp V-14 REV 00.02 SEE www.abcmetalroofing.com FOR CURRENT INFORMATION SUBJECT TO CHANGE WITHOUT NOTICE TYPICAL DETAILS VALLEY CROSS SECTION OF VALLLEY OVER WOOD DECK 5V CRIMP PANEL VALLEY TRIM(AG-237) INSIDE CLOSURE (HW-450) TRIPLE BEAD TAPESEALER (HW-502) URETHANE SEALANT (HW-540) 4¹⁄" MIN. FOR STD. VALLEY 9" FOR EXTENDED VALLEY WATERPROOFMEMBRANE WATERPROOF MEMBRANE (NOT BY MBCI) PANEL BEVEL CUT PANELTO MATCH SLOPE OF VALLEY TRIM WOOD DECK(NOT BY MBCI) VALLEY TRIM(AG-237) INSIDE CLOSURE URETHANESEALANT PANEL END DETAIL TRIPLE BEADTAPE SEALER TRIPLE BEAD TAPE SEALER ISOMETRIC VIEW OF VALLLEY OVER WOOD DECK WATERPROOF MEMBRANE 10 x 1¹⁄" LONG LIFE WOOD FASTENER(FASTENER #9)WATERPROOF MEMBRANE (NOT BY MBCI) 10 x 1¹⁄" LONG LIFE WOOD FASTENER @ 4" O.C.(FASTENER #9) 12-11 X 1" PANCAKE HEAD SELF-TAPPER @ 5'-0" O.C. (FASTENER #13) ⁄" PLYWOOD MINIMUM(NOT BY MBCI) NOTE:1. For valleys 30' or less in length, use standard valley trim. Valleys longer than 30' require extended valley trim.2. Use waterproof membrane as a waterproof membrane in the valley area.3. Apply Triple bead tape sealer to valley trim parallel to slope. Bottom edge of tape sealer is 1" from end of panel. 4. Bevel cut panel to match slope of valley trim.5. Cut "V" from inside closure. Install "V" under panel and ontop of Triple bead tape sealer. Install a bed of urethane sealant to top of "V".6. Fasten panel at valley with Fastener #9 (10 x 1Z\x" Long Life Wood Fastener) 4" O.C. maximum. DETAILS 5V Crimp SUBJECT TO CHANGE WITHOUT NOTICE SEE www.abcmetalroofing.com FOR CURRENT INFORMATION REV 00.02 V-15 TYPICAL DETAILS HIP CROSS SECTION OF HIP 5V CRIMP PANEL TRI-BEAD TAPE SEALER (HW-504) TRI-BEAD TAPE SEALER(HW-504) TRI-BEAD TAPE SEALER (HW-504) OUTSIDE CLOSURE (HW-452) (OPTIONAL) OUTSIDE CLOSURE (HW-452) (OPTIONAL) ¹⁄" x ³⁄" POP RIVET @ 6" O.C. (FASTENER #14) ¹⁄" x ³⁄" POP RIVET @ 6" O.C. (FASTENER #14) ZEE CLOSURE(AG-274) ZEE CLOSURE (AG-274) (FIELD NOTCH ATPANEL RIBS) RIDGE FLASH (AG-202) RIDGE FLASH (AG-202) ISOMETRIC VIEW OF HIP 5V CRIMP PANEL WATERPROOFMEMBRANE (NOT BY MBCI) WATERPROOF MEMBRANE(NOT BY MBCI) ⁄" PLYWOOD MINIMUM(NOT BY MBCI) ⁄" PLYWOOD MINIMUM(NOT BY MBCI) 10 x 1¹⁄" LONG LIFE WOOD FASTENER @ 1'-0" O.C.(FASTENER #9) 10 x 1¹⁄" LONG LIFE WOOD FASTENER @ 1'-0" O.C.(FASTENER #9) URETHANE SEALANT (HW-540) TO FILL VOIDS AT NOTCHEDZEE CLOSURES LOCATIONS URETHANE SEALANT (HW-540) TO FILL VOIDS AT NOTCHEDZEE CLOSURES LOCATIONS NOTE:1. Bevel cut panels to match slope of hip and install. 2. Install Tri-Bead tape sealer across panels parallel to slope of hip. Top edge of tape sealer is 1Z\x" center of hip. 3. Notch bottom flange and web of Zee closure at each "V" of the panel. Install Zee closure with Fastener #9 (10 x 1Z\x" Long Life Wood Fastener) 1'-0" O.C. Set bottom flange of Zee closure on top of tape sealer.4. Install Tri-Bead tape sealer to top flange of Zee closure and attach hip flash with Fastener #14A (Z\," x C\," Pop Rivet) 1'-0" O.C. Do not attach to Panel Rib. DETAILS 5V Crimp V-16 REV 00.02 SEE www.abcmetalroofing.com FOR CURRENT INFORMATION SUBJECT TO CHANGE WITHOUT NOTICE TYPICAL DETAILS RAKE BEGINNING/FINISHING RAKE TRIM 5V CRIMP PANEL RAKE TRIM (AG-250) RAKE TRIM(AG-250) ISOMETRIC VIEW OF BEGINNING WITH RAKE TRIM ALTERNATE BEGINNING/FINISHING DRIP TRIM 12-11 X 1" PANCAKE HEAD@ 2'-0" O.C. (FASTENER #13) 12-11 X 1" PANCAKE HEAD@ 2'-0" O.C. (FASTENER #13) 12-11 X 1" PANCAKE HEAD@ 2'-0" O.C. (FASTENER #13) 5V CRIMP PANEL DRIP TRIM(AG-279) CONTINUOUS CLEAT (FL-338) CONTINUOUS CLEAT (FL-338) 10 x 1¹⁄" LONG LIFEWOOD FASTENER (FASTENER #9) ⁄" PLYWOOD MINIMUM(NOT BY MBCI) WATERPROOF MEMBRANE(NOT BY MBCI) 10 x 1¹⁄" LONG LIFE WOOD FASTENER (FASTENER #9) 10 x 1¹⁄" LONG LIFE WOOD FASTENER (FASTENER #9) ⁄" PLYWOOD MINIMUM (NOT BY MBCI) WATERPROOF MEMBRANE (NOT BY MBCI) TRI-BEAD TAPE SEALER(HW-504) NOTE:Rake Trim1. Install rake trim to roof panels with Fastener #9 (10 x 1Z\x" Long Life Wood Fastener) 1'-0" O.C. Fasteners must go through Tri-Bead tape sealer.2. When finishing off module, field bend a Z\x" leg up on panel before installing rake trim. Alternate Drip Trim1. Fasten drip trim to roof deck with Fastener #13 (10 x 1" Pancake Head) 2'-0" O.C. 2. Cut panel and bend a 1" open hem along length of panel.3. Hook panel onto extending leg of drip trim and fasten panel to roof deck in normal manner. DETAILS 5V Crimp SUBJECT TO CHANGE WITHOUT NOTICE SEE www.abcmetalroofing.com FOR CURRENT INFORMATION REV 00.02 V-17 TYPICAL DETAILS EAVE TRIM 5V CRIMP PANEL TRI-BEAD TAPESEALER (HW-504) TRI-BEAD TAPE SEALER (HW-504) TRI-BEAD TAPESEALER (HW-504) INSIDE CLOSURE(HW-450) INSIDE CLOSURE (HW-450) EAVE TRIM (AG-246) EAVE TRIM (AG-246)CROSS SECTION OF EAVE TRIM ISOMETRIC VIEW OF EAVE TRIMPANEL END DETAIL 5V CRIMP PANEL EAVE TRIM(AG-246) WATERPROOF MEMBRANE (NOT BY MBCI) WATERPROOF MEMBRANE(NOT BY MBCI) CONTINUOUS CLEAT FASTENER #132'-0" O.C. ALTERNATE CROSS SECTION OF EAVE TRIM URETHANE SEALANT(HW-540)CONTINUOUS BEAD TOP OF CLOSURE ⁄" PLYWOOD MINIMUM(NOT BY MBCI) ⁄" PLYWOOD MINIMUM (NOT BY MBCI) 10 x 1¹⁄" LONG LIFE WOOD FASTENER @ 1'-0" O.C. (4) PER PANEL (FASTENER #9) 10 x 1¹⁄" LONG LIFE WOOD FASTENER @ 1'-0" O.C.(4) PER PANEL (FASTENER #9) 12-11 X 1" PANCAKE HEAD@ 2'-0" O.C. (FASTENER #13) URETHANE SEALANT (HW-540) CONTINUOUS BEAD TOP OF CLOSURE NOTE: 1. Attach eave trim to roof deck with Fastener #13 (10 x 1" Pancake Head) (2 fasteners per 10' section).2. Install Tri-Bead tape sealer along top leg of eave trim. Install inside closure on top of Tri-Bead tape sealer. Apply a bead of urethane sealant to top of outside closure.3. Attach panel at eave with Fastener #9 (10 x 1Z\x" Long Life Wood Fastener). Fastener pattern is shown on Page V-7. DETAILS 5V Crimp V-18 REV 00.02 SEE www.abcmetalroofing.com FOR CURRENT INFORMATION SUBJECT TO CHANGE WITHOUT NOTICE TYPICAL DETAILS GUTTER 5V CRIMP PANEL WATERPROOF MEMBRANE(NOT BY MBCI) INSIDE CLOSURE(HW-450) INSIDE CLOSURE (HW-450) GUTTER STRAP4'-0" O.C. (AG-244) BOX GUTTER(AG-242) BOX GUTTER(AG-242) PANEL END DETAIL WATERPROOF MEMBRANE (NOT BY MBCI) GUTTER STRAP 4'-0" O.C. (AG-244) 5V CRIMP PANEL CROSS SECTION OF EAVE WITH GUTTER ISOMETRIC VIEW OF EAVE WITH GUTTER TRI-BEAD TAPE SEALER (HW-504) TRI-BEAD TAPESEALER (HW-504) TRI-BEAD TAPE SEALER (HW-504) ⁄" PLYWOOD MINIMUM (NOT BY MBCI) ⁄" PLYWOOD MINIMUM(NOT BY MBCI) 10 x 1¹⁄" LONG LIFE WOOD FASTENER (4) PER PANEL (FASTENER #9) ¹⁄" x ³⁄" POP RIVET @ 6" O.C. (FASTENER #14) URETHANE SEALANT (HW-540) CONTINUOUS BEAD TOP OFCLOSURE URETHANE SEALANT (HW-540) CONTINUOUS BEAD TOP OFCLOSURE ¹⁄" x ³⁄" POP RIVET @ 6" O.C. (FASTENER #14) 10 x 1¹⁄" LONG LIFEWOOD FASTENER (4) PER PANEL (FASTENER #9) 12-11 X 1" PANCAKE HEAD@ 5'-0" O.C. (FASTENER #13) NOTE: 1. Fastener #14 (pop rivet) gutter strap to gutter 4'-0" O.C. and attch gutter to roof deck with two Fastener #13 (10 x 1" Pancake Head) per 10' section.2. Install Tri-Bead tape sealer along top leg of gutter. Install inside closure on top of Tri-Bead tape sealer. Apply a bead of urethane sealant to top of outside closure.3. Attach panel at eave with Fastener #9 (10 x 1Z\x" Long Life Wood Fastener). Fastener pattern is shown on Page V-7. DETAILS 5V Crimp SUBJECT TO CHANGE WITHOUT NOTICE SEE www.abcmetalroofing.com FOR CURRENT INFORMATION REV 00.02 V-19 TYPICAL DETAILS SLOPE CHANGE ISOMETRIC VIEW SLOPE CHANGE 5V CRIMP PANEL 5V CRIMP PANEL WATERPROOFMEMBRANE(NOT BY MBCI) WATERPROOF MEMBRANE(NOT BY MBCI) TRI-BEAD TAPE SEALER (HW-504) TOP AND BOTTOM OF CLOSURE TRI-BEAD TAPE SEALER (HW-504) TOP AND BOTTOM OF CLOSURE INSIDE CLOSURE(HW-450) INSIDE CLOSURE(HW-450) CROSS SECTION SLOPE CHANGE SLOPE TRANSITION TRIM OUTSIDE CLOSURE (HW-452) OUTSIDE CLOSURE(HW-452) 5V CRIMP PANEL TRI-BEAD TAPE SEALER PANEL END DETAIL 10 x 1¹⁄" LONG LIFEWOOD FASTENER(4) PER PANEL (FASTENER #9)⁄" PLYWOOD MINIMUM(NOT BY MBCI) ⁄" PLYWOOD MINIMUM(NOT BY MBCI) TRI-BEAD TAPE SEALER (HW-504) 12-11 X 1" PANCAKE HEAD@ 2'-0" O.C. (FASTENER #13) 10 x 1¹⁄" LONG LIFE WOOD FASTENER (4) PER PANEL(FASTENER #9) 10 x 1¹⁄" LONG LIFE WOOD FASTENER (4) PER PANEL(FASTENER #9) URETHANE SEALANT (HW-540)CONTINUOUS BEAD TOP OF CLOSURE URETHANE SEALANT (HW-540) CONTINUOUS BEAD TOP OFCLOSURE NOTE: 1. Install eave panel with Fastener #9 (10 x 1Z\x" Long Life Wood Fastener). Apply Tri-Bead tape sealant on the bottom and top of the outside closure that is mounted down hill from the end of panel.2. Install transition trim on top of the outside closure with hem of the trim being 1 inch from Fastener #9 (10 x 1Z\x" Long Life Wood Fastener) that is located 1'-0" O.C. and placed in the high part of the rib.3. Fasten down top of trim with two Fasteners #13 (10 x 1" pancake head) per 10'-0" section of trim. Place Tri-Bead tape sealant on top of trim prior to placement of inside closure. Closure should be 1" from end of panel.4. Apply a large bead of urethane sealant to top of the inside closure prior to placing panel on top of closure.5. Attach uphill panel with Fastener #9 (10 x 1Z\x" Long Life Wood Fastener). Fastener pattern is shown on Page V-7. NOTES V-20 REV 00.02 SEE www.abcmetalroofing.com FOR CURRENT INFORMATION SUBJECT TO CHANGE WITHOUT NOTICE September 3, 2019/ Rev 00.02 For the most current information available, visit our Web site at www.abcmetalroofing.com Adel, GA1601 Rogers RoadAdel, GA 31620877-595-6604 Lubbock, TX5711 East FM-40Lubbock, TX 79401877-695-0477 Memphis, TN300 Highway 51 NorthHernando, MS 38632877-774-0157 Mt. Pleasant, IA305 N. Iris RoadMt. Pleasant, IA 52641877-768-9460 Frankfort, KY1099 US-421Frankfort, KY 40601877-780-2119 Oklahoma City, OK7000 S. Eastern AvenueOklahoma City, OK 73149877-795-4399 Phoenix, AZ660 South 91st AvenueTolleson, AZ 85353877-774-6219 Rome, NY6168 State Route 233Rome, NY 13440877-785-0821 Salt Lake City, UT1155 W 2300 NSalt Lake City, UT 84116877-814-1419