Loading...
1628 BEACH AVE ROOF22-0055 r **ALrS''' Building Permit Application Updated 10/9/18 �� City of Atlantic Beach Building Department L INFORMATION l 800 Seminole Road, Atlantic Beach FL 32233 HIGHLIGHTED IN GRAY `'b;09.% Phone: (904) 247-5826 Email: Building-Dept@coab.us IS REQUIRED. Job Address: 1628 Beach Ave.Atlantic Beach, FL 32233 Permit Number: F Z Z 00 3 Legal Description 15-82 09-2S-29E OCEAN GROVE UNIT NO 1 S/D PT LOT 7 LOT 7 BLK 1 RE# 169548-0000 Valuation of Work(Replacement Cost)$ 19,800 Heated/Cooled SF Non-Heated/Cooled • Class of Work: ❑New Addition RAlteration ❑Repair ❑Move ❑Demo ❑Pool ❑Window/Door • Use of existing/proposed structure(s): ❑Commercial L3Kesidential • If an existing structure, is a fire sprinkler system installed?: ❑Yes LINo • Will tree(s)be removed in association with proposed proiect? ❑Yes(must submit separate Tree Removal Permit) Colo Describe in detail the type of work to be performed: Re-roof using architectural shingles and modified rubber on small flat section i re-- rye, Ar`-i- A /.v'5/.ec. i Mod(I,-U/lib te o F7 1rb,r( At -r-,,4 r‘ .(i.- ,1.1 Florida Florida Product Approval#GA-t-----A-46. FL /612,4 /R.Z/, FI2c33 ?/y for_multiple products use product approval form Property Owner Information Fl /cleft/2'7 r► '^)f-I.44�:� (7.4 ,t,-.1.s-c-0-0 Name James Schwab Address 1628 BEach Ave. City Atlantic Beach State FL Zip 32233 Phone 917-696-0737 E-Mail jamesschwab@gmail.com Owner or Agent(If Agent, Power of Attorney or Agency Letter Required) Contractor Information Name of Company Pimentel Roofing,lnc Qualifying Agent Ramon Pimentel Address 402 St.Augsutine Blvd City Jax Bch State FL Zip 32250 Office Phone 904-608-9950 Job Site Contact Number State Certification/Registration# CCC1330935 E-Mail pimentelroofing@gmail.com Architect Name&Phone# Engineer's Name& Phone# Workers Compensation Insurer OR Exempt ❑ Expiration Date 8/31/2024 Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all the laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING,SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS,TANKS,and AIR CONDITIONERS,etc. NOTICE: In addition to the requirements of this permit,there may be additional restrictions applicable to this property that may be found in the public records of this county,and there may be additional permits required from other governmental entities such as water management districts,state agencies, or federal agencies. OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTOY 7.FORE REC• 'D L G Y• R,NOTIZE OF COMMENCEMENT,, f Ea L d) w •(Sign r•dr wner or Agent) (Signature of Contractor) �II11inti 1// . \\\\\ G• -igt-d'ia,9• s i, . o(or affirm-d)befor- me this i - day of.Signed and sworn to(or affir ed)before m V `lL7•.•44'.,!:51,5)� ,, c..,\ •'0.1'.E E 'JUI Y('i �i � , by �_r= I 1 ( r 'i "`�/ s i� b� t� ,, f` ,-,_..0 �S, 1/ / 11t • ^ 0 0 o- P AG ,, = (Signat re of Notary) (Signat ieiif Nt ryf ,,9 _ c,: L �.• 2 �f{L'1y ,, cr ••.NH 30.:%-' $ • "//ii,/ S M d Idea f cawn nR t on I I Produced Identification /////�O�FLOR���P�\\\\\ TA)T ''"///IIIT�MPe\Ofs'Identification: Type of Identification: NOTICE OF COMMENCEMENT State of CriC16- Tax Folio No. County of DMVGI ' To Whom It May Concern: The undersigned hereby informs you that improvements will be made to certain real property, and in accordance with Section 713 of the Florida Statutes,the following information is stated in this NOTICE OF COMMENCEMENT. Legal Description of property being improved: 126a- 1(P'6 -OCct IS 9Z 09-25- 2% Oc AIJ C-t11eiNC JN(r 140 I. 5/0 7r Lc r 7 yer7 31K Address of property being improved: 1 4N 2 D �Gq„1'1ti it- /4 tCUtfL 3)'2' 72-3 General description of improvements: t\)€.1r-> Owner:3-td.kEs 514viptz, Address: I 1076 BeA * t E" 322.33 Owner's interest in site of the improvement: 0 (;1.) ) 12-{ Fee Simple Titleholder(if other than owner): Nam Contractor: 'Rik��r .� AA2 va C Address: /fd 2 < i t ( Z�5.1) Telephone No.0410) 5--G/' Cg'y Fax No: Surety(if any) Address: Amount of Bond$ Telephone No: Fax No: Name and address of any person making a loan for the construction of the improvements Name: Address: Phone No: Fax No: Name of person within the State of Florida,other than himself,designated by owner upon whom notices or other documents may be served: Name: Address: Telephone No: Fax No: In addition to himself, owner designates the following person to receive a copy of the Lienor's Notice as provided in Section 713.06(2)(b), Florida Statues. (Fill in at Owner's option) Name: Address: Telephone No: Fax No: Expiration date of Notice of Commencement(the expiration date is one (1)year from the date of recording unless a different date is specified): THIS SPACE FOR RECORDER'S USE ONLY OWNER Doc tt-YrrY13u nR BK 20459 Page 160, Signed. � AI a Date: 1 17)2° Number Pages: 1 v v Before me this 1 day of SP r PVYI Se(in the County.of Duval,State Recorded 10/10/2022 11:30 AM, Of Florida,has personally appeared gt ma>Cr lv 'C.'k\I t)c1b JODY PHILLIPS CLERK CIRCUIT COURT DUVAL COUNTY Notary Public at Large,State of Florida,County of I36uv• 4 I . - -- ------ RECORDING $10.00 My commission expires: 17/1/1?, ) !?O . "''•t• Personally Known: .11:1 brt(:Ui i FH 228151: Produced Identification: FL- 1 '`\V e r c I I Ceo. i" d.;, tArnr.8:June 14 2028 . . certalnTeed o COMMERCIAL AUJFiNG SYSTE,.:,_ Technical Data FLINTLASTIC° SA Self-Adhering SBS Modified Bitumen Mid Ply and Cap Sheet and SBS Modified Bitumen Base Sheet for SA Roof Systems. Product Ffintlastic SA roofing membrane is a premium, self-adhering SOS modified bitumen roll roofing Information material suitable for use in accordance with CertainTeed specifications for most low slope roof system applications. Refer to the CertainTeed Commercial Roof Systems Specification Manual for complete self adhered roof system specifications and application requirements. *" The Flintlastic SA line of products is more than a single membrane, it is a complete roof .- . it system designed for base and cap or base, mid-ply and cap roof system configurations. Use of Flintlastic SA Base permits complete mechanical attachment to nailable substrates; preserving the integrity of the substrate for future tear-offs and adding additional waterproofing i performance capabilities to the overall system. For larger industrial/institutional applications, Fiintlastic SA Base, Mid Ply and Cap in combination represent a premium roof system capable of meeting the performance criteria of a larger roof. Use of Flintiastic SA Base also adds to the 61171010 fire resistance of the roof system, enabling UL Listing of the roof system. When using self-adhering roofing products, particular attention must be paid to storage and handling, deck preparation, slope and drainage, and application requirements to assure a successful installation and long-term performance. Compliances Flintlastic SA roofing membranes are manufactured on state of the art, dedicated roofing lines specifically designed for the production of modified bitumen roofing membrane, and meet or St,,,-it AN°iotys� exceed the following ASTM standards: --- °�F ASTM Standard �� _. 1 . .- g��r. Flintlastic SA Base D 4601, Type Ii 1_ / S `� R�y ^ N Flintlastic SA Mid Ply D 6164 I— I(, 70 Color Companion Products" Flintlastic SA Cap 0 6164 l + �° Refer to the current UL Roof Systems Directory, or "''�- -,isti,ti �, unto en tern r<< UL's web site, WGVw.UI.COR# Labaratotie.Inc. "'°°" for the most current information on UL listing for Flintlastic SA Products. tist en External Fire aPOstva Ony .Fv Flintlastic SA Base Flinflastic SA Mid Ply Flintlastic SA Cap Sheet FlintFlashTM SA Roll Dimensions 66'5" x 39-318" 33'11°x 39-318" 33'11'x 39-3l8" 33'11"x 13-1/8" (or 9-3/4°) Thickness 1.5 mm 3.0 mm 4.0 mm 3.0 mm Weight 84 lbs 68 lbs 97 lbs 22.5 lbs (or 17 lbs) Coverage 2 Squares 1 Square 1 Square 1/3 Square (or 1/4 Square) Top Surface Permanent Film Permanent Film Mineral-Variety of Colors Permanent Film Bottom Surface Sand Removable Release Film Removable Release Film Removable Release Film Reinforcement Fiberglass Mat Polyester/Fiberglass Polyester/Fiberglass Polyester/Fiberglass Scrim Combination Mat Scrim Combination Mat Scrim Combination Mat Tensile(rhrin; 65/40 (MD/CD) 80/60 (MD/CD) 80;'55 (MD/CD) 80/60 (MD/CD) Elongation(% 6/5 (MD/CD) 50/55 (MD/CD) 50/55 (MD/CD) 50/55 (MD/CD) Packaging Palletized, Bands Individual Cartons Individual Cartons 20 rolls per pallet 20 rolls per pallet 20 rolls per pallet 3 rolls pepeIndividual Cartons, r carton (or 4) 60 rolls per pallet (or 80) installation Refer to the CertainTeed Commercial Roof Systems Specification Manual for complete product installation details and requirements. Below is a general guideline: Deck Preparation CertainTeed recommends the use of Flintlastic SA Base in conjunction with all self-adhering membrane roof installations. Non-nailable roof decks may receive direct application of 4,4\\ dki -P/9\-I'L'i k' 0\ CI!) l NEMoIetc. / 5.8 Tile Slippage Limitations(TAS 103 per FRSA/TRI April 2012(04-12)): When loading roof tiles on the underlayment in direct-deck tile assemblies, the maximum roof slope shall be as follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles. �4 ' -- ONV. , ._•`..e ms , w e6 if ,Mal :,411x ,:' , ,tt �ti t4� ,...,,,,,WA, �E+Cit'(i�E NsTALLAtion, Underlayment Tile Profile Staging Method Maximum Slope Flat Max. 10-tile stack 6:12 Lugged Max.10-tile stack 5:12 Max.10-tile stack(bottom 2-tile stack shall be inverted, •• followed by 8 tiles high on slope,as shown below) 6:12 1 Lastobond TU HT *-*-j Lugged za • Flat Max.10-tile stack 1 Colphene FR GR 5:12 --.....____4Lugged Max.10-tile stack 6:12 6- INSTALLATION: 6.1 Soprema Roof Underlayments shall be installed in accordance with Soprema published installation requirements subject to the Limitations set forth in Section 5 herein and the specifics noted below. 6.2 Re-fasten any loose decking panels,and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application,and prime the substrate with Elastocol Stick,Elastocol Stick Zero or RESISTO EXTERIOR PRIMER(if applicable). 6.3 Lastobond TU HT, Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT, Lastobond Pro HT-S,EnviroShield,Lastobond Eaves Protection Sheet, Lastobond 195, Lastobond Eco, Lastobond Smooth Seal HT,Grip-Rite Smooth Seal HT, RESISTO LB1236,Grip-Rite Eave&Valley Protector, RESISTO 181244 or Colphene FR GR: 6.3.1 Non-Tile Applications: Shall be installed in compliance with the requirements for ASTM 01970 underlayment in FBC Table 1507.1.1 or R905.1.1 for the type of prepared roof covering to be installed,and Soprema published requirements. 6.3.2 Tile Applications(Lastobond TU HT or Colphene FR GR only): Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual for Self-Adhered Membrane, and Soprema published requirements. For mechanically fastened tile roofing over a 2-ply system, consisting of Base Sheet and Self-Adhered Membrane, fastening of the ASTM D226,Type II base sheet shall be in accordance with Soprema requirements,but not less than that the densities set forth in FRSA/TRI April 2012(04-12),Table 1. For foam-on tile applications(Lastobond TU HT only), reference is made to Section 5.6.5 herein for wind resistance limitations that fall outside the scope of FRSA/TRI April 2012(04-12). Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the underlayment. See Table 3 herein,and Soprema published requirements for tile staging. MEMO ETC,LLC Evaluation Report 518010.06.09-R15 Certificate of Authorization#32455 6'EDITION(2017)FBC NON-HVHZ EVALUATION - -. Soprema Roof Underlayments Revision 15:06/19/2019 Page 7 of 8