725 ATLANTIC BLVD #11 - AWNING DWGFASTEN TO
METAL FRAMING W/
%4" X 4" S.S. SELF TAPPING
SCREWS AT 24" O/C MAX.
THRU FRAME
i
1 X2 X0.093"
FASTEN TO
METAL FRAMING W/
%4' X 4" S.S. SELF TAPPING �.
SCREWS AT 24" O/C AX.
THRU FRAME
20'-0"
3/4' O TIE BAR
ADVANCED AWNING & DESIGN
2155 CORPORATE SQUARE BOULEVARD
BUILDING 100
JACKSONVILLE, FLORIDA 32216
(904)724-5567
PROJECT:
CANTINA LOUIE
725 ATLANTIC BLVD,
ATLANTIC BEACH, FL 32233
1
/1
10/3/17 SCALE: N.T.S. BY: JR
#04572225
GENERAL NOTES
1_ ALL MEMBERS SHALL BE 6063-T6 ALUMINUM TUBE.
2: ALL OTHER MATERIAL SHALL BE 6063-T6 ALUMINUM (U.O.N.)
3. ALL CONNECTIONS SHALL BE FULLY WELDED,
4. ALL WELDS SHALL COMPLY WITH A.W.S. CODE (LATEST
EDITION)
5. ` COVER ALL WELDS WITH CORROSION RESISTANT
COATING.
6. ALL STRUCTURES DESIGNED IN ACCORDANCE WITH
SECTION 31 AND SECTION 16 OF THE FLORIDA BUILDING
CODE (2014 5TH EDITION) - ASCE 7-10.
7. AWNING COVERS SHALL BE REMOVED IN PERIODS OF HIGH
$�� 9�—��� WINDS; SPECIFICALLY WINDS IN EXCESS OF 75 M.P.H.
AWNING W/COVER WILL SUSTAIN 105 M.PH. (3 SECOND
GUST) -RISK CATEGORY 11, EXPOSURE C.
8. FRAMES WITHOUT FABRIC WILL SUSTAIN 150 M.P.H. WINDS
(3 SECOND GUST), EXPOSURE D.
9. ALL FRAMES HAVE BEEN DESIGNED USING RATIONAL
ANALYSIS.
10, ALL DIMENSIONS TO BE VERIFIED IN FIELD PRIOR TO
FABRICATION.
APPLICABLE CODES (INCLUDING LOCAL AMENDMENTS):
e 2014- 5TH EDITION FLORIDA BUILDING CODE / ASCE 7-10
���
COMPLIA 5TH EDITION FLORIDA FIRE PREVENTION CODE
REv1 wED ®� CODE
C,. OF ATLP►63 TIC 13EA :a FRAMING TO BE 1"X1"X0.093" (U.O.N.)
C SPACES EQUAL (U.O.N.)
SEE P�,FtNIITS FOR ADDITIONAL..
REQUiREME�TS AND CONDITIONS d
1 X2 X0.093 � DATE: O As
`t G�
REVIEWED By .:
o � io
O 04 V ' STA OF •° �4/
1SOMETR n Ila.; !✓
�(J LEONARD A. TYLKA JR., P.E.
Ll �n� u,��1 T &, �TED � FLORIDA LIC. NO 31738
.+TIMI �
5HEE T STRUCTURAL ENGINEER:
LTL ASSOCIATES, INC.
CONS1Jl.TINp ENGINEERS
CERTIFICATE OF AUTHORIZATION NO. 6116
5725 Corporate Way, Suite 202, West Palm Beach, Florida 33407
(561)478-1845 Fax: (561) 478-6881