36 Dudley Street PROPERTY INSPECTION 02.25.2020 / 4
North Coast Property Inspections LLC
Property Inspection Report
yam}{ �� •
fi e
na
ii4 L pS R t
At
" 111M
1 ip e
36 Dudley St., Atlantic Beach, Fl. 32233
Inspection prepared for: Matthew Poindexter & Taylor Burdette
Real Estate Agent: Kendra Robertson - Keller Williams
Date of Inspection: 2/25/2020 Time: 4:30 pm
Age of Home: Built 1962 Size: 1 ,196 sqf
Weather: Rain 65
Inspector: Daniel Cavanaugh
License #HI8077
Ponte Vedra, FL
Phone: 904-891-6674
Email: dan.cavanaugh@comcast.net
northcoastpropertyinspections.com
NORTWCOAST
PROPERTY INSPECTIONS
North Coast Property Inspections LLC 36 Dudley St., Atlantic Beach, Fl.
INTRODUCTION:
We appreciate the opportunity to conduct this inspection for you! Please carefully read your entire
Inspection Report. Call us after you have reviewed your report, so we can go over any questions
you may have. Remember, when the inspection is completed and the report is delivered, we are still
available to you for any questions you may have, throughout the entire closing process.
Properties being inspected do not "Pass" or "Fail." - The following report is based on an inspection
of the visible portion of the structure; inspection may be limited by vegetation and possessions.
Depending upon the age of the property, some items like GFCI outlets may not be installed; this
report will focus on safety and function, not current code. This report identifies specific non-code,
non-cosmetic concerns that the inspector feels may need further investigation or repair.
For your safety and liability purposes, we recommend that licensed contractors evaluate and repair
any critical concerns and defects. Note that this report is a snapshot in time. we recommend that
you or your representative carry out a final walk-through inspection immediately before closing to
check the condition of the property, using this report as a guide.
Page 1 of 35
North Coast Property Inspections LLC 36 Dudley St., Atlantic Beach, Fl.
What We Inspect:
A Home Inspection is a non-invasive visual examination of a residential dwelling, performed for a
fee, which is designed to identify observed material defects within specific components of said
dwelling. Components may include any combination of mechanical, structural, electrical, plumbing,
or other essential systems or portions of the home, as identified and agreed to by the Client and
Inspector, prior to the inspection process.
A home inspection is intended to assist in evaluation of the overall condition of the dwelling. The
inspection is based on observation of the visible and apparent condition of the structure and its
components on the date of the inspection and not the prediction of future conditions.
A home inspection will not reveal every concern that exists or ever could exist, but only those
material defects observed on the day of the inspection.
A material defect is a condition with a residential real property or any portion of it that would have a
significant adverse impact on the value of the real property or that involves an unreasonable risk to
people on the property. The fact that a structural element, system or subsystem is near, at or beyond
the end of the normal useful life of such a structural element, system or subsystem is not by itself a
material defect.
An Inspection report shall describe and identify in written format the inspected systems, structures,
and components of the dwelling and shall identify material defects observed. Inspection reports may
contain recommendations regarding conditions reported or recommendations for correction,
monitoring or further evaluation by professionals, but this is not required.
Page 2 of 35
•
North Coast Property Inspections LLC 36 Dudley St., Atlantic Beach, Fl.
Report Summary
The summary below consists of potentially significant findings. These findings can be a safety
hazard, a deficiency requiring a major expense to correct or items I would like to draw extra attention
to. The summary is not a complete listing of all the findings in the report, and reflects the opinion of
the inspector. Please review all pages of the report as the summary alone does not explain all of the
issues. All repairs should be done by a licensed & bonded tradesman or qualified professional. I
recommend obtaining a copy of all receipts, warranties and permits for the work done.
Grounds
Page 6 Item: 3 Driveway and • There is a cracked and displaced area of concrete noted in
Walkway the driveway. It appears the sub base under the concrete has
eroded in this area creating the displaced area. Recommend
repair as needed - (see photo)
Exterior Areas
Page 8 Item: 1 Exterior walls • There an exterior window that has been covered up with
OSB plywood. OSB plywood is not an acceptable exterior
grade plywood. Recommend removing the OSB and filling the
window opening with block to match the existing exterior-
(see photo)
Roof components f s *
Page 11 Item: 3 Roof covering • There is improperly installed flashing noted on the roof
surface. This condition has resulted in water intrusion.
Recommend contacting a qualified contractor for repairs -
(see photos and interior ceiling photos)
• There are no installed roof jacks around the vent pipes. This
condition can and has resulted in water intrusion.
Recommend contacting a qualified contractor for repairs -
(see photos and interior ceiling photos)
• There has been a vent pipe removed from the roof surface
and the hole was never repaired. Recommend contacting a
qualified contractor for repairs - (see photos)
• There is a bulge noted on the roof surface. The roof
sheathing in this area appears to be damaged or overlapped
in this area. Recommend contacting a qualified contractor for
repairs - (see photo)
Electrical
Page 23 Item: 6 Branch circuits & • There is an open ground receptacle present in the kitchen.
fixtures This means the third prong on an appliance plug is not getting
ground protection. This is a safety hazard. Recommend
contacting a qualified contractor for repairs - (see photo)
Water Heater
Page 29 Item: 1 Water Heater • The hot water was run for 5 minutes. No hot water was
measured with a temperature meter. The circuit breaker was
in the on position. Recommend contacting a qualified
contractor for further evaluation and repairs (see yhoto
Interior Areas
Page 3 of 35
North Coast Property Inspections LLC 36 Dudley St., Atlantic Beach, Fl.
Page 31 Item: 2 Interior ceilings • There is water damage noted on the hall bathroom and
laundry room ceilings. These area were tested with a moisture
meter and shows a high moisture content. This condition
would suggest a probable roof leak in this area. Recommend
contacting a qualified contractor for further evaluation and
repairs - (See photos)
Page 33 Item: 8 Cabinets / Counter • The cabinet drawer next to the dishwasher hits the handle of
tops the dishwasher and does not fully open. Recommend
installing a dishwasher that has a concealed handle - (see
photo)
Page 4 of 35
r
North Coast Property Inspections LLC 36 Dudley St., Atlantic Beach, Fl.
Inspection Details
1 . Attendance
In Attendance: Client present • Buyer Agent present
2. Home type
Home Type: Single Family Home
3. Occupancy
Occupancy: Vacant - Furnished • Access to some items such as: electrical
outlets/receptacles, windows, wall/floor surfaces, and cabinet interiors may
be restricted by furniture or personal belongings. Any such items are
excluded from this inspection report.
Page 5 of 35
i
North Coast Property Inspections LLC 36 Dudley St., Atlantic Beach, Fl.
Grounds
1 . Grading
Goon r� r ,r
Observations:
X • At the time of this inspection there are no noted concerns regarding the
grading and drainage.
2. Vegetation
Good Fair Poor N/A None
Observations:
X • At the time of this inspection there are no noted concerns regarding the
vegetation.
• Maintenance Tip: When landscaping, keep plants, even at full growth, at
least a foot (preferably 18 inches) from house siding and windows. Keep
trees away from foundation and roof. Plants in contact or proximity to home
can provide pathways for wood destroying insects, as well as abrade and
damage siding, screens and roofs.
3. Driveway and Walkway
Good Fair Poor N/A None
Materials: Concrete driveway noted.
X Observations:
• NOTE: It appears the original concrete under the structural posts has been
cut out and poured to a greater depth. This condition greatly increases the
stability of the footing.
• There is a cracked and displaced area of concrete noted in the driveway. It
appears the sub base under the concrete has eroded in this area creating the
displaced area. Recommend repair as needed - (see photo)
A
r,
1111
Concrete driveway Cracked and displaced concrete - carport
4. Gas meter
Good Fair Poor N/A None
X
Page 6 of 35
North Coast Property Inspections LLC 36 Dudley St., Atlantic Beach, Fl.
Foundation/crawlspace
1 . Foundation / Crawlspace
Good Fair Poor N/A None Foundation Type: Raised slab foundation
X Observations:
• At this time the foundation appears to be providing adequate support for
this dwelling based on a limited visual observation. I did not observe any
evidence that would indicate the presence of significant deflections in the
foundation. There were no notable functional problems resulting from
foundation movement.
2. Crawlspace access
Good Fair Poor N/A None
X
3. Crawlspace ventilation
Good Fair Poor N/A None
X
4. Posts and Girders
Good Fair Poor N/A None
X
5. Crawlspace electrical m _.. , , r
Good Fair Poor N/A None i
X
6. Crawlspace plumbing
tj Good Fair Poor N/A None
X
7. Crawlspace ducting "'
Good Fair Poor N/A None
X
8. Sub flooring
Good Fair Poor N/A None
X
Page 7 of 35
North Coast Property Inspections LLC 36 Dudley St., Atlantic Beach, Fl.
Exterior Areas
1 . Exterior walls
Good Fair Poor N/A None Materials: Block wall construction. • Wood siding, wood frame construction.
X Observations:
• There are two damaged window sills noted.
• There an exterior window that has been covered up with OSB plywood.
OSB plywood is not an acceptable exterior grade plywood. Recommend
removing the OSB and filling the window opening with block to match the
existing exterior- (see photo)
� vf.A
� 9t t - ,' ' *i1�
s
t.7 c
A ti i.
. e a
,t - #.
f i • a ^-a..,.„ _a_,.r,F,,,._.. .
.• $
z
.•c
a aj995R 'FR�dk+` ase_ •.... ..
Front elevation Right elevation
,L. ', e k
/i'
Rear elevation Left elevation
Page 8 of 35
North Coast Property Inspections LLC 36 Dudley St., Atlantic Beach, Fl.
i t
i,.'' ..- it f ..,-_____-_,. . ,''•
OSB inlayed in an exterior window opening - right Damaged window sill - left elevation
elevation
��:. - ;--.: �-Y
r ,. ,
__„....,,,,i.,
V
'
Damaged window sill - right elevation
2. Exterior doors
Good Fair Poor N/A None
Observations:
X • At the time of this inspection there are no noted concerns regarding the
exterior doors.
3. Exterior electrical
Good Fair Poor N/A None
Observations:
X • At the time of this inspection there are no noted concerns regarding the
exterior electrical components.
4. Exterior faucets
Good Fair Poor N/A None Faucet location: Left side of house.
X Observations:
• At the time of this inspection there are no noted concerns regarding the
exterior faucet
Page 9 of 35
North Coast Property Inspections LLC 36 Dudley St., Atlantic Beach, Fl.
5. Porches, Balconies, Decks and Carport
Good Fair Poor N/A None
Observations:
X • At the time of this inspection there are no noted concerns regarding the
side porch.
6. Exterior gates
Good Fair Poor N/A None
Gate material: Wood
X Observations:
• The gate on the left side of the house does not latch shut. Recommend
readjusting the latching hardware so the gate can be properly secured.
t L'---,...-L7
,,,
ti
I {
II
t.
r T t
v*
Gate dose not latch shut
7. Exterior fence
Good Fair Poor N/A None
Fence material: Wood
X Observations:
• At the time of this inspection there are no noted concerns regarding the
fence. yyr
- '' ' ' to' .'-6,Jkii4
t
i 11
i !
ruv
yMy ,
1 i.
a 3
am•. - ' .4'.'r'' % ,y.. ',...4`,,,,,'
Sc f f s
sv»^
^,7
Fencing
Page 10 of 35
North Coast Property Inspections LLC 36 Dudley St., Atlantic Beach, FL
Roof components
1 . Soffit & Fascia
Good Fair Poor N/A None
Observations:
X • At the time of this inspection there are no noted concerns regarding the
soffits or fascia.
2. Gutter & Down spouts
Good Fair Poor N/A None
Observations:
X • IMPROVE: No gutters or down spouts. Full installation recommended to
keep water away from structure. Water can weaken the foundation and
deteriorate the siding. Be sure to install splash blocks or extensions to carry
water away from the structure.
3. Roof covering
Good Fair Poor N/A None Materials: Architectural shingles noted.
X Observations:
• There is improperly installed flashing noted on the roof surface. This
condition has resulted in water intrusion. Recommend contacting a qualified
contractor for repairs - (see photos and interior ceiling photos)
• There are no installed roof jacks around the vent pipes. This condition can
and has resulted in water intrusion. Recommend contacting a qualified
contractor for repairs - (see photos and interior ceiling photos)
• There has been a vent pipe removed from the roof surface and the hole
was never repaired. Recommend contacting a qualified contractor for repairs
• (see photos)
• There is a bulge noted on the roof surface. The roof sheathing in this area
appears to be damaged or overlapped in this area. Recommend contacting a
qualified contractor for repairs - (see photo)
a
„
-34P4C "ft
e 'keit
•
y 1.
x r
Roof covering Roof covering
Page 11 of 35
t ,
North Coast Property Inspections LLC 36 Dudley St., Atlantic Beach, FI.
- a , ' •• Ir,.- :,-;- '-,'.: --, .., . i i
', t -,
wy.
-, u, -
_ " `
Mti�"y' . •::-i • 3
syr{`
k
\`* ,\\� s e
.
`pp..
th' ;t
Roof covering Improperly installed flashing
,,,,,1-* i .l ~ �=
p --
\ v ti ,.. '� � ✓
<,„
S
_y
y
No installed roof jack- hole in roof. No installed roof jacks
t
-. .. _.
i
r
f
f.
No installed roof jack - Improperly installed Bulging roof sheathing
flashing
Page 12 of 35
North Coast Property Inspections LLC 36 Dudley St., Atlantic Beach, Fl.
4. Chimney
Good Fair Poor N/A None
X
5. Skylights
Good Fair Poor N/A None
X
Page 13 of 35
North Coast Property Inspections LLC 36 Dudley St., Atlantic Beach, Fl.
Attic
1 . Attic access
Good Fair Poor N/A None
Observations:
X • NOTE: There is no attic access
2. Attic area
Good Fair Poor N/A None
X
3. Attic ventilation
Good Fair Poor N/A None
Observations:
X X • At the time of this inspection there are no noted concerns regarding the
ventilation of the attic.
• Soffit and ridge vent noted.
11110
tl
Under eave ventilation
4. Attic insulation
Good Fair Poor N/A None
X
5. Attic electrical
Good Fair Poor N/A None
X
6. Attic plumbing
Good Fair Poor N/A None
X
7. Attic duct Work
Good Fair Poor N/A None
X
Page 14 of 35
North Coast Property Inspections LLC 36 Dudley St., Atlantic Beach, FL
Garage
1 . Garage roof
Good Fair Poor N/A None
X
2. Garage walls -
Good Fair Poor N/A None
X
`14 Yt y:
•
.1/It
3
Carport
3. Garage floor
Good Fair Poor N/A None
X
4. Garage ceiling
Good Fair Poor N/A None
Observations:
X • At the time of this inspection there are no noted concerns regarding the
carport ceiling.
5. Garage electrical
Good Fair Poor N/A None
X
6. Garage exterior door
Good Fair Poor N/A None
X
7. Garage / House door
Good Fair Poor N/A None
X
Page 15 of 35
North Coast Property Inspections LLC 36 Dudley St., Atlantic Beach, Fl.
8. Garage vehicle door
Good Fair Poor N/A None
X
Page 16 of 35
North Coast Property Inspections LLC 36 Dudley St., Atlantic Beach, Fl.
Heat/AC
The heating, ventilation, and air conditioning and cooling system (often referred to as HVAC) is the
climate control system for the structure. The goal of these systems is to keep the occupants at a
comfortable level while maintaining indoor air quality, ventilation while keeping maintenance costs at
a minimum. The HVAC system is usually powered by electricity and natural gas, but can also be
powered by other sources such as butane, oil, propane, solar panels, or wood.
The inspector will usually test the heating and air conditioner using the thermostat or other controls.
For a more thorough investigation of the system please contact a licensed HVAC service person.
1 . AC Compressor / Condenser
Good Fair Poor N/A None Condenser Type: Central air : Heat pump - MFR date 2019
X Condenser location: The compressor/ condenser is located in the back of the
house.
Observations:
• At the time of this inspection there are no noted concerns regarding the AC
compressor/condenser.
• This unit achieved a temperature of 111 degrees in the heating mode.
• The typical temperature differential split between supply and return air in an
air conditioner of this type is 15 - 20 degrees F. This system responded and
achieved an acceptable differential temperature of 18 degrees - cooling
mode
• A heat pump is basically a compressor- cycle air conditioning system that
can operate in reverse. As long as the unit is functioning properly in either
the heating or cooling mode, it is an indication that the major components
(compressor, fans, and coils) are operational.
Goodman AC unit- MFR date - 2019 AC disconnect
2. Air handler / Furnace
Good Fair Poor N/A None Location: The air handler is located in the hall closet.
X Type: Forced air heat pump - MFR date 2019
Observations:
• At the time of this inspection there are no noted concerns regarding the air
handler.
Page 17 of 35
North Coast Property Inspections LLC 36 Dudley St., Atlantic Beach, Fl.
I. 11i
t
1 \ b
II a
r
as
aut
Goodman air handler- MFR date - 2019 Evaporating coil
- :., -; i ' ,.
t
4411414111 - 17, -
.- P�
Condensate drain line - condensate pump - safety switch
3. Air supply / return
Good Fair Poor N/A None
Observations:
X • The air return/supply system is functional.
Page 18 of 35
North Coast Property Inspections LLC 36 Dudley St.. Atlantic Beach, FI.
I / il :'s F
iI -in F r 2s
t 1 1
Nitzisoil d,i- 4 , _. ,.
Airgatomer ,i 1:: ' 7!''':.S.
k 'i C !- ...rr
Supply air - 111 degrees - heating mode Return air- 63 degrees - cooling mode
'el. 1
illi 11-2:—:-.
Supply air - 45 degrees - cooling mode
4. Filter
Good Fair Poor N/A None Filter location: Located inside air handler cabinet.
X Observations:
• The HVAC filter was checked and is clean and functional.
Page 19 of 35
North Coast Property Inspections LLC 36 Dudley St., Atlantic Beach, Fl.
� ,
nix
t
Filter size - 16 x 20 x 1
5. Thermostat
Good Fair Poor N/A None
Observations:
X • The thermostat was operated in normal mode and was functioning normally
at the time of this inspection.
• Thermostats are not checked for calibration or timed functions.
• Location: Living room
entyoA
C
en
z
Pro Stat digital thermostat
6. Venting
Good Fair Poor N/A None
X
7. Window / Wall AC or Heat
Good Fair Poor N/A None
X
Page 20 of 35
North Coast Property Inspections LLC 36 Dudley St., Atlantic Beach, Fl.
Electrical
1 . Service entrance
Good Fair Poor N/A None
Observations:
X • At the time of this inspection there are no noted concerns regarding the
service entrance wires.
• There is overhead service noted.
//
0 i 1 : * ' . - i,-;_.7-7"..4 ,„:
Pir7 ‘ --., '.„: 1 •"-- -,, 0,
fp
,kYy- =. .fir to
ti`
Overhead service wires
2. Electrical panel
Good Fair Poor N/A None
Observations:
X • At the time of this inspection there are no noted concerns regarding the
electrical service panel.
. !
Op MI; ', •r is
l' -
I
Siemens- 150 amp service panel
3. Main breaker
Good Fair Poor N/A None
Main breaker size: 150 amp
X Cable feeds:
• The main shut off breaker is located on the left side of the house.
• Aluminum cable feeds noted
Page 21 of 35
North Coast Property Inspections LLC 36 Dudley St., Atlantic Beach, Fl.
•
ffy r —
e '. ' i
`r3
e _
Main electrical shut off breaker
4. Circuit breakers
Good Fair Poor N/A None
Breaker type: Siemens
X Branch wire type: Copper sheathed cable . • Aluminum sheathed cable noted
- 240 circuits only
Observations:
• At the time of this inspection there are no noted concerns regarding the
circuit breakers.
•
iii , 4
I
1,.....
S'r- iesS ,j .
4„,
e ;.
Siemens circuit breakers
5. Fuses
Good Fair Poor N/A None
X
Page 22 of 35
North Coast Property Inspections LLC 36 Dudley St., Atlantic Beach, Fl.
6. Branch circuits & fixtures
Good Fair Poor N/A None
Observations:
X • All accessible receptacles were tested and functioning.
• All accessible GFI receptacles were tested and functioning.
• The reset for the bathroom GFI receptacles is in the hall bath.
• All light fixtures were turned on and functioning.
• There is an open ground receptacle present in the kitchen. This means the
third prong on an appliance plug is not getting ground protection. This is a
safety hazard. Recommend contacting a qualified contractor for repairs -
(see photo)
.. _
mar
4
I" t., LLA
. mo. 's ''''''=:. s. ~ ' _
Open ground receptacle - kitchen
7. Smoke detectors
Good Fair Poor N/A None
Observations:
X • All smoke detectors were tested and are functioning.
8. Ceiling fans
Good Fair Poor N/A None
Observations:
X • At the time of this inspection there are no noted concerns regarding the
ceiling fans.
9. Bath exhaust fan
Good Fair Poor N/A None
Observations:
X • The bathroom exhaust fans were operated and functioning normally.
10. Door bell
Good Fair Poor N/A None
X
Page 23 of 35
North Coast Property Inspections LLC 36 Dudley St., Atlantic Beach, FL
Plumbing
Plumbing is an important concern in any structure. Moisture in the air and leaks can cause mildew,
wallpaper and paint to peel, and other problems. The home inspector will identify as many issues as
possible but some problems may be undetectable due to problems within the walls or under the
flooring.
Note : If in a rural location, sewer service and/or water service might be provided by private a waste
disposal system and/or well. The Inspection, testing, analysis, or opinion of condition and function of
private waste disposal systems and wells is not within the scope of this home inspection.
Recommend
consulting with seller concerning private systems and inspection, if present, by appropriate licensed
professional familiar with such private systems. If a Septic System is on the property, pumping is
generally recommended prior to purchase, and then every three years.
1 . Water shut off location
Good Fair Poor N/A None
Location:
X • The water shut off valve is located on the left side of the house.
, , ....•, ...,- ,, v. ,., _ , 4 it V * i ft*
ftit,
b
'- t , * ts` V~ i4 ".fir
f^ o'
,
f
-s 1 "3s ,
"r v
r
ii. / . .
Main water shut off valve
2. Water pressure
Good Fair Poor N/A None
Static Pressure:
X • Typical
3. Pressure regulator
Good Fair Poor N/A None
X
4. Water supply lines
Materials: Fixture supply line: CPVC
Materials: Drain piping: Unable to determine
Page 24 of 35
North Coast Property Inspections LLC 36 Dudley St., Atlantic Beach, Fl.
5. Sinks / Faucets / Drains
Good Fair None
Observations:
X • At the time of this inspection there are no noted concerns regarding the
sinks, faucets or drains.
• IMPROVE: The kitchen fixture is slightly loose at the counter top.
Recommend resecuring the fixture
r-1.-r--',.-_. -,1111-11 PIIIIIIILINITS111.1"51" _ mow
t
r fly ' r
'� 7 Ya,
" ,fi►; „
•
r-
;t ,
t:{ i a �.' f t '".o i ,,, ., 414; •
,,may„
a
a.=
Kitchen Loose at counter top
� ,:
•.
L--
_ ,
,,
1
•+� { - f { 1
It '.,.8. i .,..: • : •.!
I
..P , .b._: _w
4 L r .
r 1 P► T"1"1.: 'yam
. • ,• )r .. i.. '/ i. .,7 ,?.. ° . ` �rY . • a x
Kitchen sprayer Master bath - right side
Page 25 of 35
North Coast Property Inspections LLC 36 Dudley St., Atlantic Beach, Fl.
{
-
r
v- .,
f'r
r h - - :
r' ,. t*,ti a ll . 't :•••• :41.—
A ..
r `4.
111111
AP
w
4a
Master bath - left side Hall bath
6. Showers
Good Fair Poor N/A None
Observations:
X • At the time of this inspection there are no noted concerns regarding the
showers.
111P _
motti.......� xs illi.
.-.t,i�
3 'r w.. nsisii _
Master bath Hall bath
7. Bath tubs
Good Fair Poor N/A None
X
Page 26 of 35
North Coast Property Inspections LLC 36 Dudley St., Atlantic Beach, Fl.
,« j
I
IA44
1,;',„''''''::: ,—; A
Hall bath
8. Toilets
Good Fair Poor N/A None
Observations:
X • At the time of this inspection there are no noted concerns regarding the
toilets.
• IMPROVE: The hall bathroom toilet tank is awkwardly mounted.
Recommend repair as needed - (see photo)
a
•
Master bath Hall bath
Page 27 of 35
North Coast Property Inspections LLC 36 Dudley St., Atlantic Beach, Fl.
411111.:::;
Toilet tank is awkwardly mounted - hall bath
9. Hydro - Therapy tub
Good Fair Poor N/A None
X
Page 28 of 35
North Coast Property Inspections LLC 36 Dudley St., Atlantic Beach, Fl.
Water Heater
1 . Water Heater
Good Fair Poor N/A None
Energy source: Electric
X Location: The water heater is located in the laundry room.
Observations:
• Water temperature observed to be: 67 degrees.
• The hot water was run for 5 minutes. No hot water was measured with a
temperature meter. The circuit breaker was in the on position. Recommend
contacting a qualified contractor for further evaluation and repairs - (see
photo)
_
•
AO Smith- 40 gallon water heater Water temperature 67 degrees
2. Number of gallons
ood Fair Poor N/A None
obsevations: 40 gallons
X
3. TPR valve
Good Fair Poor N/A None
Observations:
X • At the time of this inspection there are no noted concerns regarding the
TPR valve.
• A Temperature and Pressure Relief Valve (TPR Valve) is present. This
safety valve releases water (and thus relieves pressure) if either the temp or
pressure in the tank gets too high.
Page 29 of 35
North Coast Property Inspections LLC 36 Dudley St., Atlantic Beach, Fl.
.k
4
1
1
\ it..
TPR valve
4. TPR drain line
Good Fair Poor N/A None
Materials: CPVC
X Observations:
• At the time of this inspection there are no noted concerns regarding the
TPR drain line.
1p
r
L
}
F
TPR drain line
5. Venting
Good Fair Poor N/A None
X
Page 30 of 35
a
North Coast Property Inspections LLC 36 Dudley St., Atlantic Beach, Fl.
Interior Areas
Interior areas consist of bedrooms, baths, kitchen, laundry, hallways, foyer, and other open areas.
All exposed walls, ceilings and floors will be inspected. Doors and windows will also be
investigated for damage and normal operation.Although excluded from inspection requirements, we
will inform you of obvious broken gas seals in windows. Please realize that they are not always
visible, due to temperature, humidity, window coverings, light source, etc. Our inspection will report
visible damage and moisture problems if seen. Personal items in the structure may
prevent the inspector from viewing all areas, as the inspector will not move personal items.
1 . Interior walls
Good Fair Poor N/A None Wall material: There are drywall walls noted.
X Observations:
• At the time of this inspection there are no noted concerns regarding the
interior walls.
2. Interior ceilings
Good Fair Poor N/A None Ceiling material: There are drywall ceilings noted.
X Observations:
• There is water damage noted on the hall bathroom and laundry room
ceilings. These area were tested with a moisture meter and shows a high
moisture content. This condition would suggest a probable roof leak in this
area. Recommend contacting a qualified contractor for further evaluation
and repairs - (See photos)
63.3 L F 71.3
ABY? y,
---9--
•
FLIR 62.2
Water damaged ceiling - Hall bath Thermal image of water intrusion - Hall bathroom
Page 31 of 35
r a
North Coast Property Inspections LLC 36 Dudley St., Atlantic Beach, Fl.
' yes't4 d ' ''.q..,‘"‘,R $ k
.may } �`'�`�� �'�
krM
Huh moisture content - hall bathroom ceiling Water damaged ceiling - Laundry room
»63.5 'F - 68.6
Y
-
�,e
.``
—, _
L
. ket k
ms{ .
0 1.2
Thermal image of water intrusion - Laundry room High moisture content - Laundry room ceiling
ceiling
3. Interior floors - - - .raA.
Good Fair Poor N/A None Flooring Material: Tile flooring is noted. • Vinyl flooring is noted
X Observations:
• At the time of this inspection there are no noted concerns regarding the
floors.
4. Interior windows
Good Fair Poor N/A None Window type: Aluminum framed, single hung, single pane windows noted.
X Observations:
• All accessible windows were operated and functioning.
• NOTE: A visual inspection of the windows indicates that all of the screens
are missing.
5. Interior doors
Good Fair Poor N/A None
Observations:
X • At the time of this inspection there are no noted concerns regarding the
interior doors.
Page 32 of 35
A , i
North Coast Property Inspections LLC 36 Dudley St., Atlantic Beach, Fl.
6. Interior closets
Good Fair Poor N/A None
Observations:
X • At the time of this inspection there is no noted concerns regarding the
closets.
7. Stairs & Handrail „F
Good Fair Poor N/A None
X
8. Cabinets / Counter tops
Good Fair Poor N/A None
Observations:
X • The cabinet drawer next to the dishwasher hits the handle of the _,,,,i,,,,,,:,,,,,,,,..\:,,,z1:7:1,,,b....:::,.....,..,
dishwasher and does not fully open. Recommend installing a dishwasher that
has a concealed handle - (see photo)
imik
w �, .,�
T _ < ' "-
4 FF 7
F
IIII
fr.:
rq:
.,+, a -.,, .•,.yz=xx"a."- '., ate;
a
slio
vil ..l
Ilk 2
Kitchen cabinets and counter tops Cabinet drawer hits dishwasher handle
9. Fireplace
Good Fair Poor N/A None
X
Page 33 of 35
4 . . .
North Coast Property Inspections LLC 36 Dudley St., Atlantic Beach, Fl.
Appliances
1 . Dishwasher
Good Fair Poor N/A None
Observations:
X • The dishwasher was operated in normal mode and is functioning normally.
.r _ v w.m. •�4_
igi:_,..2-4-zi7;7424-._ , ' 4: _ . ,
;,
Samsung dishwasher
2. Cook top / Range
Good Fair Poor N/A None
Observations:
X • Cook top / Range: Electric heating coils.
• All elements operated when tested.
• 1111411 ;
r
#Y
..., us �. 1.
— — = '"-----,, —__=.--
Samsung range
3. Oven
Good Fair Poor N/A None
Observations:
X • The oven was operated in a normal mode and is functioning normally.
Page 34 of 35
Y
.1 I , V
North Coast Property Inspections LLC 36 Dudley St., Atlantic Beach, Fl.
fro s
.. . .41t1:11111 ‘ i .
.�..— 1 eta- .,., F
D
Iskanl fRlnu.ltll Y _
_
a
11.:-:--/ ' ' 1111.-- - _
. 1*;
ti-111
f7—_7 T-7-7i ,
/ / / 7-r--------r ______
Baking mode Broiling element
4. Vent
Good Fair Poor N/A None
Vent type: Recirculating
X Observations:
• The exhaust fan under the microwave was operated and is functioning
normally.
5. Microwave
Good Fair Poor N/A None
Observations:
X • The microwave was operated in a normal mode and is functioning normally.
it I
11 '
I
I
�r
4i
Samsung microwave
6. Garbage disposal
Good Fair Poor N/A None
X
7. Dryer vent
Good Fair Poor N/A None
Observations:
X • The dryer vent appears to properly vent to the exterior.
Page 35 of 35