Loading...
102 Aquatic Drive (Bldg 6) ELEVATION 09.15.2017 U.S. DEPARTMENT OF HOMELAND SECURITY OMB No. 1660-0008 Federal Emergency Management Agency Expiration Date: November 30,2018 National Flood Insurance Program ELEVATION CERTIFICATE Important: Follow the instructions on pages 1-9. Copy all pages of this Elevation Certificate and all attachments for(1)community official,(2)insurance agent/company,and(3)building owner. SECTION A—PROPERTY INFORMATION FOR INSURANCE COMPANY USE Al. Building Owner's Name Policy Number: TBR AQUATIC OWNER LLC A2. Building Street Address(including Apt., Unit,Suite, and/or Bldg. No.)or P.O.Route and Company NAIC Number Box No. 102 AQUATIC DRIVE-BLDG 6 City State ZIP Code ATLANTIC BEACH Florida 32233 A3. Property Description(Lot and Block Numbers,Tax Parcel Number, Legal Description,etc.) PART OF SECTION 38,TOWNSHIP 2 SOUTH, RANGE 29 EAST; RE#177603-0000 A4. Building Use(e.g., Residential, Non-Residential,Addition,Accessory,etc.) RESIDENTIAL A5. Latitude/Longitude: Lat. 30° 19'33.3"N Long. 81°24'49.1"W Horizontal Datum: ❑ NAD 1927 ❑x NAD 1983 A6. Attach at least 2 photographs of the building if the Certificate is being used to obtain flood insurance. A7. Building Diagram Number 1B A8. For a building with a crawlspace or enclosure(s): a) Square footage of crawlspace or enclosure(s) N/A sq ft b) Number of permanent flood openings in the crawlspace or enclosure(s)within 1.0 foot above adjacent grade N/A c) Total net area of flood openings in A8.b N/A sq in d) Engineered flood openings? ❑Yes ❑ No A9. For a building with an attached garage: a) Square footage of attached garage 882 sq ft b) Number of permanent flood openings in the attached garage within 1.0 foot above adjacent grade 6 c) Total net area of flood openings in A9.b 740 sq in d) Engineered flood openings? x❑Yes ❑ No SECTION B—FLOOD INSURANCE RATE MAP(FIRM) INFORMATION B1. NFIP Community Name&Community Number B2. County Name B3. State CITY OF ATLANTIC BEACH 120075 DUVAL Florida B4. Map/Panel rB5. Suffix B6. FIRM Index 87. FIRM Panel 88. Flood Zone(s) B9. Base Flood Elevation(s) Number I Date Effective/ (Zone AO,use Base Revised Date Flood Depth) 12031C0408 H 06/03/2013 06/03/2013 AE 6 B10. Indicate the source of the Base Flood Elevation(BFE)data or base flood depth entered in Item B9: ❑FIS Profile ❑x FIRM ❑ Community Determined ❑ Other/Source: B11. Indicate elevation datum used for BFE in Item B9: ❑ NGVD 1929 ❑x NAVD 1988 ❑ Other/Source: B12. Is the building located in a Coastal Barrier Resources System(CBRS)area or Otherwise Protected Area(OPA)? ❑Yes x❑ No Designation Date: ❑ CBRS ❑ OPA FEMA Form 086-0-33(7/15) Replaces all previous editions. Form Page 1 of 7 OMB No. 1660-0008 ELEVATION CERTIFICATE Expiration Date:November 30,2018 IMPORTANT: In these spaces,copy the corresponding information from Section A. FOR INSURANCE COMPANY USE Building Street Address(including Apt, Unit,Suite,and/or Bldg.No.)or P.O. Route and Box No. Policy Number 102 AQUATIC DRIVE-BLDG 6 City State ZIP Code Company NAIC Number ATLANTIC BEACH Florida 32233 SECTION C—BUILDING ELEVATION INFORMATION(SURVEY REQUIRED) Cl. Building elevations are based on: 0 Construction Drawings* ❑Building Under Construction* ❑x Finished Construction *A new Elevation Certificate will be required when construction of the building is complete. C2. Elevations—Zones A1—A30,AE,AH,A(with BFE),VE,V1—V30,V(with BFE),AR,AR/A,AR/AE,AR/A1 A30,AR/AH,AR/AO. Complete Items C2.a—h below according to the building diagram specified in Item A7.In Puerto Rico only,enter meters. Benchmark Utilized: 4.96(COMMENT) Vertical Datum: NAVD 1988 Indicate elevation datum used for the elevations in items a)through h)below. ❑ NGVD 1929 ❑x NAVD 1988 ❑Other/Source: Datum used for building elevations must be the same as that used for the BFE. Check the measurement used. a) Top of bottom floor(including basement,crawlspace,or enclosure floor) 8. 5 ❑x feet ❑ meters b) Top of the next higher floor 19. 9 x❑ feet ❑ meters c) Bottom of the lowest horizontal structural member(V Zones only) NSA. ❑ feet 0 meters d) Attached garage(top of slab) 8. 0 ❑X feet ❑ meters e) Lowest elevation of machinery or equipment servicing the building 8. 5 ❑x feet ❑ meters (Describe type of equipment and location in Comments) f) Lowest adjacent(finished)grade next to building(LAG) 7. 7 ❑x feet ❑ meters g) Highest adjacent(finished)grade next to building(HAG) 7. 9 0 feet ❑ meters h) Lowest adjacent grade at lowest elevation of deck or stairs,including NSA. ❑ feet 0 meters structural support SECTION D—SURVEYOR,ENGINEER,OR ARCHITECT CERTIFICATION This certification is to be signed and sealed by a land surveyor,engineer,or architect authorized by law to certify elevation information. I certify that the information on this Certificate represents my best efforts to interpret the data available.I understand that any false statement maybe punishable by fine or imprisonment under 18 U.S.Code, Section 1001. Were latitude and longitude in Section A provided by a licensed land surveyor? El Yes ❑No ❑x Check here if attachments. Certifier's Name License Number DONN W BOATWRIGHT,PSM LS 3295 Title PRESIDENT nQ Company Name '''a - ' '`) BOATWRIGHT LAND SURVEYORS, INC '"eal " 41 Address r ere-• MA) 1500 ROBERTS DE City State ZIP Code 3' JACKSONV LE B.AC Florida 32250 Signature ' Date Telephone 9/15/2017 904241-8550 Copy all pages of th "evation Certificate and all attachments for(1)community official,(2)insurance agent/company,and(3)building owner. Comments(including type of equipment and location,per C2(e),if applicable) A5-INFORMATION OBTAINED FROM ITOUCHMAP.COM A9-SMARTVENT 1540-570-COVERAGE IS 200 SQUARE FEET PER VENT-TOTAL COVERAGE 1200 C2-BENCHMARK-N RIM SMH C/L OF AQUATIC DR @ RESIDENCE#561 AQUATIC DR. C2a-LOWEST FINSIHED FLOOR OF HABITABLE SPACE C2b-2ND STORY FINISHED FLOOR HABITABLE SPACE. C2e-WATER HEATER&AIR HANDLER LOCATED IN MECHANICAL ROOM ATTACHMENTS-FIRMETTE, 1ST FLOOR PLAN, FLOOD VENT CERTIFICATION FEMA Form 086-0-33(7/15) Replaces all previous editions. Form Page 2 of 7 ELEVATION CERTIFICATE OMB No. 1660-0008 Expiration Date: November 30,2018 IMPORTANT:In these spaces,copy the corresponding information from Section A. FOR INSURANCE COMPANY USE Building Street Address(including Apt., Unit, Suite,and/or Bldg. No.)or P.O. Route and Box No. Policy Number: 102 AQUATIC DRIVE-BLDG 6 City State ZIP Code Company NAIC Number ATLANTIC BEACH Florida 32233 SECTION E—BUILDING ELEVATION INFORMATION(SURVEY NOT REQUIRED) FOR ZONE AO AND ZONE A(WITHOUT BFE) For Zones AO and A(without BFE),complete Items El—E5. If the Certificate is intended to support a LOMA or LOMR-F request, complete Sections A, B,and C. For Items E1—E4, use natural grade, if available. Check the measurement used. In Puerto Rico only, enter meters. El. Provide elevation information for the following and check the appropriate boxes to show whether the elevation is above or below the highest adjacent grade(HAG)and the lowest adjacent grade(LAG). a) Top of bottom floor(including basement, crawlspace, or enclosure)is ❑feet ❑metersabove or ❑ ❑below the HAG. b) Top of bottom floor(including basement, crawlspace, or enclosure)is ❑feet ❑meters ❑above or ❑below the LAG. E2. For Building Diagrams 6-9 with permanent flood openings provided in Section A Items 8 and/or 9(see pages 1-2 of Instructions), the next higher floor(elevation C2.b in the diagrams)of the building is . —, ❑ ❑meters ❑above or ❑below the HAG. E3. Attached garage(top of slab)is ❑feet ❑meters ❑above or ❑below the HAG. E4. Top of platform of machinery and/or equipment servicing the building is ❑feet ❑meters ❑above or ❑below the HAG. E5. Zone AO only: If no flood depth number is available, is the top of the bottom floor elevated in accordance with the community's floodplain management ordinance? ❑ Yes ❑ No ❑ Unknown. The local official must certify this information in Section G. SECTION F—PROPERTY OWNER(OR OWNER'S REPRESENTATIVE)CERTIFICATION The property owner or owner's authorized representative who completes Sections A, B,and E for Zone A(without a FEMA-issued or community-issued BFE)or Zone AO must sign here.The statements in Sections A, B,and E are correct to the best of my knowledge. Property Owner or Owner's Authorized Representative's Name Address City State ZIP Code Signature Date Telephone Comments ❑Check here if attachments. FEMA Form 086-0-33(7/15) Replaces all previous editions. Form Page 3 of 7 OMB No. 1660-0008 ELEVATION CERTIFICATE Expiration Date: November 30,2018 IMPORTANT:In these spaces,copy the corresponding information from Section A. FOR INSURANCE COMPANY USE Building Street Address(including Apt.,Unit,Suite,and/or Bldg.No.)or P.O.Route and Box No. Policy Number. 102 AQUATIC DRIVE-BLDG 6 City State ZIP Code Company NAIC Number ATLANTIC BEACH Florida 32233 SECTION G—COMMUNITY INFORMATION(OPTIONAL) The local official who is authorized by law or ordinance to administer the community's floodplain management ordinance can complete Sections A, B,C(or E),and G of this Elevation Certificate.Complete the applicable item(s)and sign below.Check the measurement used in Items G8—G10.In Puerto Rico only,enter meters. G1. ❑ The information in Section C was taken from other documentation that has been signed and sealed by a licensed surveyor, engineer,or architect who is authorized by law to certify elevation information.(Indicate the source and date of the elevation data in the Comments area below.) G2 0 A community official completed Section E for a building located in Zone A(without a FEMA-issued or community-issued BFE) or Zone AO. — G3. 0 The following information(Items G4—G10)is provided for community floodplain management purposes. G4. Permit Number G5. Date Permit Issued G6. Date Certificate of Compliance/Occupancy Issued G7. This permit has been issued for: ❑ New Construction ❑ Substantial Improvement G8. Elevation of as-built lowest floor(including basement) of the building: ❑feet 0 meters Datum G9. BFE or(in Zone AO)depth of flooding at the building site: 0 feet Elmeters Datum G10. Community's design flood elevation: 0 feet ❑meters Datum Local Official's Name Title Community Name Telephone Signature Date Comments(including type of equipment and location,per C2(e), if applicable) ❑ Check here if attachments. FEMA Form 086-0-33(7/15) Replaces all previous editions. Form Page 4 of 7 BUILDING PHOTOGRAPHS OMB No. 1660-0008 ELEVATION CERTIFICATE See Instructions for Item A6. Expiration Date: November 30, 2018 IMPORTANT: In these spaces, copy the corresponding information from Section A. FOR INSURANCE COMPANY USE Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.)or P.O. Route and Box No. Policy Number: 102 AQUATIC DRIVE- BLDG 6 City State ZIP Code Company NAIC Number ATLANTIC BEACH Florida 32233 If using the Elevation Certificate to obtain NFIP flood insurance, affix at least 2 building photographs below according to the instructions for Item A6. Identify all photographs with date taken; "Front View"and"Rear View"; and, if required, "Right Side View" and "Left Side View." When applicable, photographs must show the foundation with representative examples of the flood openings or vents, as indicated in Section A8. If submitting more photographs than will fit on this page, use the Continuation Page. r ii 11 a + • �,T '1•1111,1111E IM MI III • • NI III III IN IN III . :77,4441114 09/15/2017 09 .09 ‘4411111111111i 4s. 111,1111111111111 Photo One Caption FRONT VIEW _ m.3333f.� . ../ RAP.Aferrill Ilya,illi ._ ,,. n ., II44 „ ,..---: ..44.-.., itf ..{t i# F +l jJ1fliiiLId[UUIII , JI!IIinhtlflu1tMIIIIiJ1LJIIt..JII' J!t11L, _ o°aigaaon o° :n Photo Two Caption REAR VIEW FEMA Form 086-0-33(7/15) Replaces all previous editions. Form Page 5 of 7 BUILDING PHOTOGRAPHS OMB No. 1660-0008 ELEVATION CERTIFICATE Continuation Page Expiration Date: November 30, 2018 IMPORTANT: In these spaces, copy the corresponding information from Section A. FOR INSURANCE COMPANY USE Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.)or P.O. Route and Box No. Policy Number: 102 AQUATIC DRIVE-BLDG 6 City State ZIP Code Company NAIC Number ATLANTIC BEACH Florida 32233 If submitting more photographs than will fit on the preceding page, affix the additional photographs below. Identify all photographs with: date taken; "Front View" and "Rear View"; and, if required, "Right Side View" and "Left Side View." When applicable, photographs must show the foundation with representative examples of the flood openings or vents,as indicated in Section A8. • 1 illlllllll I r WI Ei ii 111 14 1 '' , ,_ .11' ii i 1. s1 -1~ :n�! L. IIIIIII IIIIIIIIIIIIIIII IIIIIIIIIIIIILII IIIIIIIIIIIIIIII IIIIIIIIIIIIiiil r 09r1:5i/2.017 09:10 Photo One Caption RIGHT SIDE VIEW 3. g.. 4 A14...4,4,i 4A ,.,.,..,0 -' ' ' n t. 4t#4,— 0 ,«1 ti ..x 41: 5. ., : # F 3.11111/iii, .,►owilimiop Li, . -tit , _... , „.. .._. ...,,. ... ....:. . „ a . t S �A,� 09115/2017109:12k': .; Photo Two Caption LEFT SIDE VIEW FEMA Form 086-0-33(7/15) Replaces all previous editions. Form Page 6 of 7 BUILDING PHOTOGRAPHS OMB No. 1660-0008 ELEVATION CERTIFICATE Continuation Page Expiration Date: November 30, 2018 IMPORTANT: In these spaces, copy the corresponding information from Section A. FOR INSURANCE COMPANY USE Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.)or P.O. Route and Box No. Policy Number: 102 AQUATIC DRIVE- BLDG 6 City State ZIP Code Company NAIC Number ATLANTIC BEACH FL 32233 If submitting more photographs than will fit on the preceding page. affix the additional photographs below. Identify all photographs with: date taken; "Front View" and "Rear View"; and, if required, "Right Side View" and "Left Side View." When applicable, photographs must show the foundation with representative examples of the flood openings or vents,as indicated in Section A8. 4. .gam - - ��— ENGINEERED 4 •r ---`— _ FLOOD i 7- s, b OPENINGS IIIII�II' "" _ r 08/1J57P29?79048•- P.' Photo One Caption TYPICAL FLOOD OPENINGS ENGINEERED r . , FLOOD ,--- 'orium iv • • Nill im um MI OM II 111 1111 OPENINGS -4 -- fll+� -_ 119piY 09/15/2017 09:09 w Photo Two Caption TYPICAL FLOOD OPENING FEMA Form 086-0-33(7/15) Replaces all previous editions. Form Page 7 of 7 National Flood Hazard Layer FIRMette 30'19'45.18"N .' 0 Legend rn ,i %,.` tic4.- ' . — Cross-Sections N �,` .lit ov 74 i ,-• • -' Base Flood Elevations NIP Flood Hazard Zones t.t -- ' 1%Annual Chance Flood "1 •$ t.-:. , "'' r..3 +...� ,� ■ Regulatory Floodway . •-" { . .-�. � • • . Special Floodway •• ` es s ''ter . , Area of Undetermined Flood Hazard G t _ ,, 0.2%Annual Chance Flood fs� ' ----IL... 4 • • ,�. , , 7 ult.......„......;„:„..,' ir Future Conditions 1%Annual Chance •' • %� Flood Hazard ^� + • , BLDG 6 - 102 ~. ,1 FA Area with Reduced Risk Due to Levee + _ t.. • ( • -- AQUATIC DRIVE ., _ LOMRs �, t """ Effective • - y 12Wt'408H ;w.;rr, �r . ..,.. i .ti .r^ a .ir •f V% .. i 7 Map Panels ..._:e 2013 G _ h: , y _ i al Data - #A��'e Digit — y — t "..a l ' rti. • : ` -+ Unmodernized Maps L"V •. . � ` 4".." Unmapped • - AREA OF MINIMAL FLOOD HAZARD Zone".. .* : ... -± . �7: + +r t +° ..✓� • -1 ' This mapcomplies with FEMA's standards for the use of •;.e ° _ - . j, * L digital flood maps. The flood hazard information is '� '" a� 3 * �+ t r derived directly from the authoritative NFHL web services „„ 3 -- .- s• :f ro ; t +” p ' , • .11 ti' provided by FEMA. The base map shown complies with t • '1w..• I. FEMA's base map accuracy standards.ie r �• - .�7»� ;, r .F.� _ • { The NFHL is a living database, updated daily, and this 1*� • '�+- -•,t ''� • `' maprepresents a snapshot of information at a specific l���� J400006time. t �! R II Flood risks are dynamic and can change frequently due to 4 , a variety of factors, including weather patterns, erosion, • r,' V 1\ , s"""''..4 and new development. FEMA flood maps are continually a j ' - • 1 ` � r ' updated through a variety of processes. Users should " '1 .�� 1'1 • -''1iiii: always verify through the Map Service Center A„," �; ISsemir - t, (http'//msc fema.gov) or the Community Map Repository �' \ e " '# . V►, - - y ` that they have the current effective information. .-1 kr 'it :" ` NFHL maps should not be created for unmapped or ,y , ` , ., or, -• • unmodernized areas. rt ! ♦' ,llik ra • 1 '• ti '4.\ P- ,r 0*`14i' `t. A ~ f !"" ' T-4 tvotry . it . - , - _ - . • -• � i. t4. ^w } FEMA ,..., ,,.w .. .,..,,,, ,„ .. ,'�! 4... • • ...,,. • i ,� 1., - �'v t - fCal:I tuI1 g hoimagery "IND sF`• mose Feet ,. - .:7"N 0 250 500 1,000 1,500 2,000 Date: 10/2/2017 Time: 12:17:07 PM ESICC Most Widely Accepted and Trusted EVALUATION SERVICE Innovation PESEARGH LnB5 ICC-ES Evaluation Report ESR-2074 Reissued 02/2019 ICC-ES 1 (800)423-6587 I (562) 699-0543 1 www.icc-es.org This report is subject to renewal 02/2021. DIVISION: 08 00 00—OPENINGS SECTION: 08 95 43—VENTS/FOUNDATION FLOOD VENTS REPORT HOLDER: SMART VENT PRODUCTS, INC. EVALUATION SUBJECT: SMART VENT® AUTOMATIC FOUNDATION FLOOD VENTS: MODELS #1540-520; #1540-521; #1540-510; #1540-511; #1540-570; #1540-574; #1540-524; #1540-514 FLOOD VENT SEALING KIT #1540-526 ICCICCECS---4441$ ICC PMG44) LISTED 9I" "2014 Recipient of Prestigious Western States Seismic Policy Council jINTERNATIONAL (WSSPC)Award in Excellence" A Subsidiary of COVECOUNCR ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed,nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use. ANSI There is no warranty by ICC Evaluation Service, LLC, express or implied, as to any finding or other matter in this A.ll,. Il) report, or as to any product covered by the report. Pros.ci a soar moo Copyright°2019 ICC Evaluation Service, LLC. All rights reserved. ES ' Most Widely Accepted and Trusted ICC-ES Evaluation Report ESR-2074 Reissued February 2019 This report is subject to renewal February 2021. www.icc-es.orq J (800)423-6587 I (562)699-0543 A Subsidiary of the international Code Council® DIVISION:08 00 00—OPENINGS Each unit is fabricated from stainless steel. Smart Vent® Section:08 95 43—Vents/Foundation Flood Vents Automatic Foundation Flood Vents are available in various models and sizes as described in Table 1. The REPORT HOLDER: SmartVENT®Stacking Model#1540-511 and FloodVENT® Stacking Model #1540-521 units each contain two SMART VENT PRODUCTS, INC. vertically arranged openings per unit. 3.2 Engineered Opening: EVALUATION SUBJECT: The FVs comply with the design principle noted in Section SMART VENT®AUTOMATIC FOUNDATION FLOOD 2.7.2.2 and Section 2.7.3 of ASCE/SEI 24-14 [Section VENTS:MODELS#1540-520;#1540-521;#1540-510;#1540- 2.6.2.2 of ASCE/SEI 24-05 (2012, 2009, 2006 IBC and 511;#1540-570;#1540-574;#1540-524;#1540-514 IRC)j for a maximum rate of rise and fall of 5.0 feet per FLOOD VENT SEALING KIT#1540-526 hour(0.423 mm/s). In order to comply with the engineered opening requirement of ASCE/SEI 24, Smart Vent FVs 1.0 EVALUATION SCOPE must be installed in accordance with Section 4.0. Compliance with the following codes: 3.3 Ventilation: • 2018,2015, 2012, 2009 and 2006 international Building Code® The SmartVENT® Model #1540-510 and SmartVENT® ®(IBC) Overhead Door Model#1540-514 both have screen covers with 11a-inch-by-1/4-inch (6.35 by 6.35 mm) openings, • 2018, 2015, 2012, 2009 and 2006 international yielding 51 square inches(32 903 mm2)of net free area to Residential Code®(IRC) supply natural ventilation. The SmartVENT® Stacking • 2018 International Energy Conservation Code®(IECC) Model #1540-511 consists of two Model #1540 510 units in one assembly, and provides 102 square inches • 2013 Abu Dhabi International Building Code(ADIBC)1 (65 806 mm2)of net free area to supply natural ventilation. tThe ADIBC is based on the 2009 IBC.2009 IBC code sections referenced Other FVs recognized in this report do not offer natural in this report are the same sections In the ADIBC. ventilation. Properties evaluated: 3.4 Flood Vent Sealing Kit: • Physical operation The Flood Vent Sealing Kit Model#1540-526 is used with SmartVENT® Model #1540-520. It is a Homasote 440 ( • Water flow Sound Barrier® (ESR-1374) insert with 21 – 2-inch-by-2- 2.0 USES inch(51 mm x 51 mm)squares cut in it.See Figure 4. The Smart Vent® units are engineered mechanically 4.0 DESIGN AND INSTALLATION operated flood vents (FVs) employed to equalize 4.1 SmartVENT®and FloodVENT®: hydrostatic pressure on walls of enclosures subject to SmartVENT® and FloodVENT® are designed to be rising or falling flood waters. Certain models also allow installed into walls or overhead doors of existing or new natural ventilation. construction from the exterior side. Installation of the 3.0 DESCRIPTION vents must be in accordance with the manufacturer's 3.1 General: instructions, the applicable code and this report. installation clips allow mounting in masonry and concrete When subjected to rising water, the Smart Vent® FVs walls of any thickness. in order to comply with the internal floats are activated,then pivot open to allow flow in engineered opening design principle noted in Section either direction to equalize water level and hydrostatic 2.7.2.2 and 2.7.3 of ASCE/SEI 24-14 [Section 2.6.2.2 of pressure from one side of the foundation to the other.The ASCE/SEI 24-05 (2012, 2009, 2006 IBC and IRC)], the FV pivoting door is normally held in the closed position by Smart Vent®FVs must be installed as follows: a buoyant release device. When subjected to rising water, • With a minimum of two openings on different sides of the buoyant release device causes the unit to unlatch, each enclosed area. allowing the door to rotate out of the way and allow flow. The water level stabilizes, equalizing the lateral forces. • With a minimum of one FV for every 200 square iCC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed,nor are they to be construed a as an endorsement of the subject of the report or a recommendation for its use.There is no warranty by ICC Evaluation Service,LLC,express or implied as to any finding or other matter in this report,or as to any product covered by the report. Copyright®2019 ICC Evaluation Service,LLC. All rights reserved. Page 1 of 5 ESR-2074 I Most Widely Accepted and Trusted Page 2 of 5 feet (18.6 m2) of enclosed area, except that the 5.2 The Smart Vent FVs must not be used in the place SmartVENTe Stacking Model #1540-511 and of"breakaway walls"in coastal high hazard areas, but FloodVENT® Stacking Model #1540-521 must be are permitted for use in conjunction with breakaway installed with a minimum of one FV for every walls in other areas. 400 square feet(37.2 m2)of enclosed area. 6.0 EVIDENCE SUBMITTED ■ Below the base flood elevation. 6.1 Data in accordance with the ICC-ES Acceptance ■ With the bottom of the FV located a maximum of Criteria for Mechanically Operated Flood Vents 12 inches (305.4 mm) above the higher of the final (AC364), dated August 2015 (editorially revised grade or floor and finished exterior grade immediately October 2017). under each opening. 6.2 Test report on air infiltration in accordance with ASTM 4.2 Flood Vent Sealing Kit E283. The Flood Vent Sealing Kit Model 1540-526 is used in 7.0 IDENTIFICATION conjunction with FloodVENTQ° Model #1540-520. When 7.1 The Smart VENT'models and the Flood Vent Sealing installed and tested in accordance with ASTM E283, the Kit recognized in this report must be identified by a FV and Flood Vent Sealing Kit assembly have an air label bearing the manufacturer's name (Smartvent leakage rate of less than 0.2 cubic feet per minute per Products, Inc.), the model number,and the evaluation lineal foot (18.56 I/min per lineal meter) at a pressure differential of 1 pound per square foot (50 Pa) based on report number(ESR 2074). 12.58 lineal feet(3.8 lineal meters)contained by the Flood 7.2 The report holder's contact information is the Vent Sealing Kit. following: 5.0 CONDITIONS OF USE SMART VENT PRODUCTS,INC. 430The Smart Vent® FVs described in this report comply with, PITMAN,NEW JERSEY,U08071IT 1 or are suitable alternatives to what is specified in, those (877) 1 68 codes listed in Section 1.0 of this report, subject to the www.smartvent.com followingconditions: info(a)smartvent.com 5.1 The Smart Vents FVs must be installed in accordance with this report, the applicable code and the manufacturer's installation instructions.In the event of a conflict,the instructions in this report govern. TABLE 1—MODEL SIZES MODEL NAME MODEL NUMBER MODEL SIZE(in.) COVERAGE(sq.ft.) FloodVENTe 1540-520 153/4"X 73/4" 200 SmartVENT® 1540-510 15314"X 73/4" 200 FloodVENT®Overhead Door 1540-524 _ 153/4"X 73/4' 200 • SmartVENT®Overhead Door 1540-514 153/4"X 73/4" 200 Wood Wall FloodVENTe 1540-570 14"X 83/4" 200 Wood Wall FloodVENTe Overhead Door 1540-574 14"X 83/4" 200 ! SmartVENT®Stacker 1540-511 16"X 16" 400 I FloodVente Stacker _ 1540-521 16"X 16" 400 For SI: 1 inch=25.4 mm;1 square foot=m2 • , j i su --axu -s:ceG `'-` k, F.e, r!raearaarrar aerate! t '��aeaaaeaaerare■rr6 aaaeaearatareter, r/1 '1 Al r arraeaeaeieeenSV 'eco rautre"rrgas'13a"o I ' QraTi atera"rrarraarablt QaL""aa6Cr6 stifaee6"S Er,. ..A. [# 14•tcaaia"a3 taaaaeeeer e•• • aeasaef9Gaia" ceetae, 44 a. •seaieYrr'raccceeeaaaaae'•eY Ca..' a a....a aII s•su, aea:6 ar ai0eQQ ee Q6' ,#S E1... .71 ; 19taitYci!66acY1 3 ,-tcaaeeaea.Yaaaea ias a♦iI SRateei 2846 : waseeaaeaeeri cacerc"eeaar C. ca n rlsaaeirar ereo '---comas"-J-"crani--i e :obwairaataci"6 . . . - _ < ' tri x S.: ••l.e e.. - itieaa.rteaei aY e•enreo,taepraeaaaadi '#g...er',coalreeeer1 fri-1 "rr:-.7.1-...leeeSGaaaicaY:Qe ,i� `, _. ■■■ 4 tireaaas8aarraaaalia .aa .la.. aareer®actc)GfeY ' ,i \ I7sS.ter.-=2Z3= 5:::a.__—'Z _ fF m1,rs-+-a....-.•e .. +:: I l{ ,77,""N.,-,sri-s .'i' -'"r...-r. vc....wr ,. 4^ /F2 R - �� FIGURE 1—SMART VENT:MODEL 1540-510 y ' ESR-2074 I Most Widely Accepted and Trusted Page 3 of 5 • • ,. FIGURE 2—SMART VENT MODEL 1540-520 Mr 4 �'t F FIGURE 3—SMART VENT: SHOWN WITH FLOOD DOOR PIVOTED OPEN • 4 I 11111111 1� INTERIOR EXTERIOR FIGURE 4—FLOOD VENT SEALING KIT ES4'F ^nz.a,�n Most Widely Accepted and Trusted ICC-ES Evaluation Report ESR-2074 CBC and CRC Supplement Reissued February 2019 This report is subject to renewal February 2021. www.icc-es.orq I (800) 423-6587 I (562) 699-0543 A Subsidiary of the International Code Council® DIVISION:08 00 00—OPENINGS Section: 08 95 43—Vents/Foundation Flood Vents REPORT HOLDER: SMART VENT PRODUCTS, INC. EVALUATION SUBJECT: SMART VENT®'AUTOMATIC FOUNDATION FLOOD VENTS:MODELS#1540-520;#1540-521;#1540-510;#1540-511;#1540- 570;#1540-574;#1540-524;#1540-514 FLOOD VENT SEALING KIT#1540-526 1.0 REPORT PURPOSE AND SCOPE Purpose: The purpose of this evaluation report supplement is to indicate that Smart Vent® Automatic Foundation Flood Vents, recognized in ICC-ES master evaluation report ESR-2074, have also been evaluated for compliance with codes noted below. Applicable code edition: • 2016 California Building Code(CBC) • 2016 California Residential Code(CRC) 2.0 CONCLUSIONS 2.1 CBC: The Smart Vent®Automatic Foundation Flood Vents, described in Sections 2.0 through 7.0 of the master evaluation report ESR-2074, comply with 2016 CBC Chapter 12, provided the design and installation are in accordance with the 2015 International Building Code® (IBC) provisions noted in the master report and the additional requirements of CBC Chapters 12, 16 and 16A, as applicable. The products recognized in this supplement have not been evaluated under CBC Chapter 7A for use in the exterior design and construction of new buildings located in any Fire Hazard Severity Zone within State Responsibility Areas or any Wildland-Urban Interface Fire Area. 2.2 CRC: The Smart Vent®Automatic Foundation Flood Vents, described in Sections 2.0 through 7.0 of the master evaluation report ESR-2074, comp with the 2016 CRC, provided the design and installation are in accordance with the 2015 International Residential Code (IRC)provisions noted in the master report. The products recognized in this supplement have not been evaluated under 2016 CRC Chapter R337, for use in the exterior design and construction of new buildings located in any Fire Hazard Severity Zone within State Responsibility Areas or any Wildland-Urban Interface Fire Area. The products recognized in this supplement have not been evaluated for compliance with the International Wildland–Urban Interface Code®. This supplement expires concurrently with the master report, reissued February 2019. 1CC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed,nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use.There is no warranty by ICC Evaluation Service,LLC,express or implied,as to any finding or other matter in this report,or as to any product covered by the report. Copyright©2019 ICC Evaluation Service,LLC. All rights reserved. Page 4 of 5 ES Most Widely Accepted and Trusted ICC-ES Evaluation Report ESR-2074 FBC Supplement Reissued February 2019 This report is subject to renewal February 2021. www.icc-es.orq I (800)423-6587 I (562) 699-0543 A Subsidiary of the International Code Council® DIVISION:08 00 00—OPENINGS Section:08 95 43—Vents/Foundation Flood Vents REPORT HOLDER: SMART VENT PRODUCTS,INC. EVALUATION SUBJECT: SMART VENT®AUTOMATIC FOUNDATION FLOOD VENTS:MODELS#1540-520;#1540-521;#1540-510;#1540-511; #1540-570;#1540-574;#1540-524;#1540-514 FLOOD VENT SEALING KiT#1540-526 1.0 REPORT PURPOSE AND SCOPE Purpose: The purpose of this evaluation report supplement is to indicate that Smart Vent®Automatic Foundation Flood Vents,recognized in ICC-ES master report ESR-2074,have also been evaluated for compliance with the codes noted below. Applicable code editions: ■ 2017 Florida Building Code—Building ■ 2017 Florida Building Code—Residential 2.0 CONCLUSIONS The Smart Vent®Automatic Foundation Flood Vents, described in Sections 2.0 through 7.0 of the master evaluation report ESR-2074, comply with the Florida Building Code—Building and the FRC, provided the design and installation are in accordance with the 2015 International Building Code®provisions noted in the master report. Use of the Smart Vent®Automatic Foundation Flood Vents has also been found to be in compliance with the High-Velocity • Hurricane Zone provisions of the Florida Building Code—Building and the Florida Building Code—Residential. For products falling under Florida Rule 9N-3,verification that the report holder's quality assurance program is audited by a quality assurance entity approved by the Florida Building Commission for the type of inspections being conducted is the responsibility of an approved validation entity(or the code official when the report holder does not possess an approval by the Commission). This supplement expires concurrently with the master report,reissued February 2019. ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributer not specifically addressed,nor are they to be construed II ANSI as an endorsement of the subject of the report or a recommendation far its use There is no warranty by iCC Evaluation Service,LLC,express or implied as to any finding or other matter in this report,or as to any product covered by the report. . aa _ .. Copyright C 2019 ICC Evaluation Service,LLC. All rights reserved. Page 5 05