1889 BEACH AVE ROOF22-0063 COAB Permit Form with ConditionsOWNER:ADDRESS:CITY:STATE:ZIP:
EMANS CHRISTOPHER F 1651 SEMINOLE RD ATLANTIC BEACH FL 32233-5855
COMPANY:ADDRESS:CITY:STATE:ZIP:
FORD ROOFING SYSTEMS
INC 3839 Millpoint Drive Jacksonville FL 32257
TYPE OF
CONSTRUCTION:
REAL ESTATE
NUMBER:ZONING:BUILDING USE
GROUP:SUBDIVISION:
169686 0000 NORTH ATLANTIC BCH
UNIT 2
JOB ADDRESS:PERMIT TYPE:DESCRIPTION: VALUE OF WORK:
1889 BEACH AVE ROOF NON SHINGLE METAL ROOF $58000.00
LIST OF CONDITIONS
Roll off container company must be on City approved list . Container cannot be placed on City right-of-way.
1 BUILDING NOTICE OF COMMENCEMENT INFORMATIONAL
Notes:
No inspections may be scheduled until a copy a recorded Notice of Commencement has been submitted to the Building Department
NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property
that may be found in the public records of this county, and there may be additional permits required from other
governmental entities such as water management districts, state agencies, or federal agencies.
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN
YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT
MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU
INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE
RECORDING YOUR NOTICE OF COMMENCEMENT.
MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION.
ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING
CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES .
ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY.
1 of 2Issued Date:
PERMIT NUMBER
ROOF22-0063
ISSUED:
EXPIRES:
ROOF NON SHINGLE PERMIT
CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
ATLANTIC BEACH, FL 32233
FEES
DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT
BUILDING PERMIT 455-0000-322-1000 0 $312.00
BUILDING PLAN CHECK 455-0000-322-1001 0 $156.00
STATE DBPR SURCHARGE 455-0000-208-0700 0 $7.02
STATE DCA SURCHARGE 455-0000-208-0600 0 $4.68
TOTAL: $479.70
2 BUILDING ROOF IN-PROGRESS INSPECTION REQUIRED INFORMATIONAL
Notes:
a. The roof sheathing for all new construction must remain uncovered until the Roof Sheathing Inspection is approved.
b. All roofing projects require an In-Progress Inspection.
c. Sheathing installation and replacement guidelines per APA.
d. Underlayment must conform to FBC-R Table 905.1.1
e. Shingles must conform to ASTM D3161 G or H, or ASTM D7158 F
2 of 2Issued Date:
PERMIT NUMBER
ROOF22-0063
ISSUED:
EXPIRES:
ROOF NON SHINGLE PERMIT
CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
ATLANTIC BEACH, FL 32233
Building
V ccd-e_s RES Ol,,
Permit Application Updated 10/9/18Pp
q
City of Atlantic Beach Building Department ALL INFORMATION
800 Seminole Road, Atlantic Beach, FL 32233 HIGHLIGHTED IN GRAY
Phone: (904) 247-5826 Email: Building-Dept coab.us,,
IS REQUIRED. /
Job Address: Fii- b r:O O F Z 6(v
Legal Description — # - r .
C
as — M e,titik V rove' (A-k-T-Ft”RE# 167-454, 641,01,C--1
Valuation of Work(Replacement Cost)$ J'g 000 Heated/Cooled SF Non-Heated/Cooled
Class of Work: New IXAddition Alteration Repair Move Demo Pool Window/Door
Use of existing/proposed structure(s): Commercial A132.sidential
If an existing structure,is a fire sprinkler system installed?: Yes No N/4
Will tree(s) be removed in association with proposed roiect? Yes(must submit separate Tree Removal Permit) 44.1110
1----Describe in detail the type of work to be performed: me cv
f
R
Florida Product Approval# 3 g D I % I for multiple products use product approval form
Pro•ert Owner Information
Name C> ' i1 c-•-'- Address f 4, 51 Se.-.1A-c.;‘,1.0/e., I2 L
City A , ' iG e.e State G- Zip 3.9-23 Phone —75q — 9.Y. 6, .-7
E-Mail re--y- a. 5.;,..,£eotc,,a,AL 5 S -Gower
Owner or Agent(If Agent, Power of Attorney or Agency Letter Required) /e S( We -c-c._.
Contractor Information
R2o' 15} s Qualifyingg h r '] MNameofCompany -t)T'c. + f Agent '-
Address j$3q AA ;/!po,.1-c•t City 73—A x State FL— Zip 3.2257
Office Phone f d` ' 5'f 4 .
2C6,-
7 I Job Site Contact Number „....5-c-4-4-44-A--e„....5-c-4-4-44-A--e___/„....5-c-4-4-44-A--e___
State Certification/Registration# C-/ 76 9 E-Mail _.0, - Ch ?5'f" .lJl [` L l -Co
Architect Name& Phone#
Engineer's Name& Phone#
Workers Compensation Insurer OR Exempt o Expiration Date
Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has
commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all the laws regulating
construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS,
WELLS, POOLS, FURNACES, BOILERS, HEATERS,TANKS, and AIR CONDITIONERS, etc. NOTICE: In addition to the requirements of this
permit,there may be additional restrictions applicable to this property that may be found in the public records of this county, and
there may be additional permits required from other governmental entities such as water management districts,state agencies, or
federal agencies.
OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all
applicable laws regulating construction and zoning.
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY
RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND
TO OBTAIN FIN; NCING, CONSULT WITH YOUR LENDER OR A A : : : EY BEFORE
RECORDI , =
Atoo01
tiR NO -0E-COMMENCEMENT.
Signature o •w r Agent)Signature of Contractor)
Si ed a d •' Orn to(or affirm e • - r• this 7 da. of Si ed nd sworn to(or affir -.) •efore e this . dae____Jgrow,
s Y 47ure o k d6`,1AUs' 1 v)-------------
z /.,,.... Notary Public-State or Flonda
G; Commission#HH 212979
4p .P`B`
c GREGORY J.BARTHOLOMEW
PersonallyKnown OR '?crc°' My Comm.Expires Jan 3,2026 Personal) Known OR951321yCommission#GG
OLOME
Produced Identification Bonded through National Notary Assn. [
J Produced Identification '", ”°'o Expires February 6,2024
Type of Identification: Type of Identification: FOFFLO" Bonded Nu BudgetNotary$ms
By Mike Jones at 2:25 pm, Nov 29, 2022
REVIEWED FOR CODE COMPLIANCE
,i,,,='-','''-,,,..,,,, Building Permit Application Updated 10/9/18
City of Atlantic Beach Building Department **ALL INFORMATION
;V / 800 Seminole Road, Atlantic Beach, FL 32233 HIGHLIGHTED IN GRAY
�';�r IS REQUIRED.
Phone: (904) 247-5826 Email: Building-Dept@coab.us
Job Address: 1889 BEACH AVE Atlantic Beach FL 32233 Permit Number:
Legal Description 15-57 09-2S-29E NORTH ATLANTIC BEACH UNIT NO 02 LOT 47 RE# 169686-0000
Valuation of Work(Replacement Cost)$ 65000 Heated/Cooled SF Non-Heated/Cooled
• Class of Work: ❑New ❑Addition gAlteration ORepair ❑Move ❑Demo ❑Pool ❑Window/Door
• Use of existing/proposed structure(s): ❑Commercial ❑Residential
• If an existing structure,is a fire sprinkler system installed?: ❑Yes ❑No
• Will tree(s)be removed in association with proposed project? ❑Yes(must submit separate Tree Removal Permit) ❑No
Describe in detail the type of work to be performed: Metal Re Roof
Florida Product Approval# 33818.1 for multiple products use product approval form
Property Owner Information
Name Christopher Emans Address 1651 Seminole Rd.
City Atlantic Beach State FL Zip 32233 Phone 9047599867
E-Mail rex(@_sighomesf).com
Owner or Agent(If Agent,Power of Attorney or Agency Letter Required) Rex Williams
Contractor Information
Name of Company Ford Roofing Systems Inc. Qualifying Agent Robert Maust
Address 3839 Millpoint Dr City Jacksonville State FL Zip 32257
Office Phone 9043147671 Job Site Contact Number 9043147671
State Certification/Registration# CCC1327698 E-Mail fordroofing(a�gmail.com
Architect Name&Phone#
Engineer's Name&Phone#
Workers Compensation Insurer OR Exempt❑ Expiration Date
Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has
commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all the laws regulating
construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING,SIGNS,
WELLS, POOLS,FURNACES, BOILERS,HEATERS,TANKS,and AIR CONDITIONERS,etc. NOTICE: In addition to the requirements of this
permit,there may be additional restrictions applicable to this property that may be found in the public records of this county,and
there may be additional permits required from other governmental entities such as water management districts,state agencies,or
federal agencies.
OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all
applicable laws regulating construction and zoning.
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE 0 :, MENCEMENT MAY
RESULT IN YOUR PAYING CE FO' PROVEMENTS TO •U t 'ROPERTY. IF YOU INTEND
TO OBT f AN •NS I H YOUR LEN O' ATTORNEY : FORE
PP
REC• :'6 0 ,i• lt• e I • : . ,•i,,-ICE, , - IT
rtur- !,,,O#e'r or Agent) , i ature of Contractor)
Si:j•: and .;orn to(or affirm-d .- or- this da. . "S ned arid sworn to(or affirmet be • - is AMP day of
°f- f/ , J022 ,by • i DJ ApV 1r, x.012 b - 0'cr�ii(r
JACOB MAUST JACOB MAUSTf Flor da
/ A_PUB .'LIy-Y P�je
;=°�\(r Notary Public-State of Florida _����Lr, Notary Public State o
~`" Commission;HH 22979
[ ]Personally Known OR ` '..a. "a Commission Ht-182n123"29026
H 2;2979 ,.- .- .Wally Known OR'.=-.; - `
' aN My Comm.Extiires;ar 3,2025 ,.,�o , My Comm.Expires Jan 3,2026
I ]Produced Identification [ I Produced Identificati e. h National Notary Assn.
Type of Identification: Bonded through National notary Assn. Type of Identification: Bonded throng
Building Permit Application Updated 10/9/18
4k.:J
_T City of Atlantic Beach Building Department **ALL INFORMATION
800 Seminole Road, Atlantic Beach, FL 32233 HIGHLIGHTED IN GRAY
� ;�
�' r IS REQUIRED.
Phone: (904) 247-5826 Email: Building-Dept@coab.us
Job Address: 1889 BEACH AVE Atlantic Beach FL 32233 Permit Number:
Legal Description 15-57 09-2S-29E NORTH ATLANTIC BEACH UNIT NO 02 LOT 47 RE# 169686-0000
Valuation of Work(Replacement Cost)$ 65000 Heated/Cooled SF Non-Heated/Cooled
• Class of Work: ❑New ❑Addition tfAlteration ❑Repair ❑Move ❑Demo ❑Pool ❑Window/Door
• Use of existing/proposed structure(s): ❑Commercial ❑Residential
• If an existing structure, is a fire sprinkler system installed?: ❑Yes ❑No
• Will tree(s)be removed in association with proposed project? ❑Yes(must submit separate Tree Removal Permit) ❑No
Describe in detail the type of work to be performed: Metal Re Roof
Florida Product Approval# 33818.1 for multiple products use product approval form
Property Owner Information
Name Christopher Emans Address 1651 Seminole Rd.
City Atlantic Beach State FL Zip 32233 Phone 9047599867
E-Mail rex(c sighomesfl.com
Owner or Agent(If Agent,Power of Attorney or Agency Letter Required) Rex Williams
Contractor Information
Name of Company Ford Roofing Systems Inc. Qualifying Agent Robert Maust
Address 3839 Millpoint Dr city Jacksonville State FL Zip 32257
Office Phone 9043147671 Job Site Contact Number 9043147671
State Certification/Registration# CCC1327698 E-Mail fordroofingna gmail.com
Architect Name&Phone#
Engineer's Name&Phone#
Workers Compensation Insurer OR Exempt o Expiration Date
Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has
commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all the laws regulating
construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING,SIGNS,
WELLS, POOLS,FURNACES, BOILERS,HEATERS,TANKS,and AIR CONDITIONERS,etc. NOTICE:In addition to the requirements of this
permit,there may be additional restrictions applicable to this property that may be found in the public records of this county,and
there may be additional permits required from other governmental entities such as water management districts,state agencies,or
federal agencies.
OWNER'S AFFIDAVIT:I certify that all the foregoing information is accurate and that all work will be done in compliance with all
applicable laws regulating construction and zoning.
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE 0 o' MENCEMENT MAY
RESULT IN YOUR PAYING CE FO' : PROVEMENTS TO •U : •ROPERTY. IF YOU INTEND
TO OBT h'AN •NS I H YOUR LEN •' O' ATTORNEY : FORE
REC• :j„�,�i►• • I • ' • ,•'► .CE► , - ,T
atur .f er or Agent) /_�ature of Contractor)
Si:j•: and .' orn to(or affirmcd .• or this da• .'� Si ned and sworn to(or affirme- be . - is day of
°f” e JP 2 ,by • . 11) ivo va•4 e--, 201.2- ,b - •, /i(�
^��pv r�.,. JACOB MAUS^f JACOB MAUST
' �r:- Notary Public-State Florida /� (Z' ''',":..PUNotary Public-State of Florida
-.
PersonallyKnown OR '.a'. o; Commission HH 2:2979 .. Commission HH 212979
[ ] / .Wally Known OR�,.'.�-��:\,,S7'. %.71
[ J Produced Identification ' '', d'` My Comm.Ex;ires;ar 3.2026 [ ]produced Identificati., MY Comm.Expires Jan 3,2026
Bonded through National Notary Assn.
Type of Identification: Bonded through National-otary Assn. Type of Identification: _
r1752E.,: Registry No. 29824
c,»
Rn
CREEK 0 Edinburgh Dr
Tampa, FL 33647
TECHNICAL SERVICES. LLC 813)480-3421
EVALUATION REPORT FLORIDA BUILDING CODE,7TH EDITION(2020)
Manufacturer: GULF COAST SUPPLY& MANUFACTURING, LLC Issued October 21, 2021
14429 SW 2nd Place, Suite G30
Newberry, FL 32669
352)498-7852
www.gulfcoastsupply.com
Manufacturing Locations: Alachua, FL
Sebring, FL
Montgomery, AL
Quality Assurance: PRI Construction Materials Technologies, LLC (QUA9110)
SCOPE
Category: Roofing
Subcategory:Metal Roofing
Code Sections: 1504.3
Properties: Wind Resistance
REFERENCES
Entity Report No. Standard Year
Force Engineering&Testing(TST5328) 72-0313T-06A-C UL 580 2006
UL 1897 2012
Force Engineering&Testing(TST5328) 72-0198T-07A-C UL 580 2006
UL 1897 2012
Force Engineering&Testing(TST5328) 117-0033T-05 UL 580 2006
UL 1897 2012
Force Engineering&Testing(TST5328) 117-0053T-05 UL 580 2006
UL 1897 2012
Force Engineering&Testing(TST5328) 117-0062T-07A-C UL 580 2006
UL 1897 2012
Force Engineering&Testing(TST5328) 117-0062T-07D-F UL 580 2006
UL 1897 2012
Force Engineering&Testing(TST5328) 117-0062T-07G-1 UL 580 2006
UL 1897 2012
Force Engineering&Testing(TST5328) 117-0062T-07J-K UL 580 2006
UL 1897 2012
Force Engineering&Testing(TST5328) 117-0065T-07A-C UL 580 2006
UL 1897 2012
Force Engineering&Testing(TST5328) 117-0076T-12A UL 580 2006
UL 1897 2012
Force Engineering&Testing(TST5328) 117-0089T-05.1 UL 580 2006
UL 1897 2012
Force Engineering&Testing(TST5328) 117-0089T-05.2 UL 580 2006
UL 1897 2012
Force Engineering&Testing(TST5328) 117-0102T-05 UL 580 2006
UL 1897 2012
Force Engineering&Testing(TST5328) 117-0165T-11B UL 580 2006
UL 1897 2012
Force Engineering&Testing(TST5328) 117-0238T-09D FM 4471 1992
Force Engineering&Testing(TST5328) 117-0238T-09E FM 4471 1992
Force Engineering&Testing(TST5328) 117-0238T-11A FM 4471 1992
Force Engineering&Testing(TST5328) 117-0248T-07A,B UL 580 2006
UL 1897 2012
Force Engineering&Testing(TST5328) 117-0284T-09A UL 580 2006
UL 1897 2012
GCS20002.2a FL33818-R2 Page 1 of 6
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
By Mike Jones at 2:25 pm, Nov 29, 2022
CREEK GULF COAST SUPPLY&MANUFACTURING, LLC
Metal Roofing
TECHNICAL SERVICES, LLC
Entity Report No. Standard Year
Force Engineering&Testing(TST5328) 117-0285T-09A UL 580 2006
UL 1897 2012
Force Engineering&Testing(TST5328) 117-0301T-10A-C UL 580 2006
UL 1897 2012
Force Engineering&Testing(TST5328) 117-0330T-10A-B UL 580 2006
UL 1897 2012
Force Engineering&Testing(TST5328) 117-0331T-08A UL 580 2006
UL 1897 2012
Force Engineering&Testing(TST5328) 117-0331T-08B UL 580 2006
UL 1897 2012
Force Engineering&Testing(TST5328) 117-0331T-08D UL 580 2006
UL 1897 2012
Force Engineering&Testing(TST5328) 117-0337T-10 UL 580 2006
UL 1897 2012
Force Engineering&Testing(TST5328) 117-0378T-11A FM 4471 1992
Force Engineering&Testing(TST5328) 117-0378T-11B FM 4471 1992
Force Engineering&Testing(TST5328) 117-0378T-11C FM 4471 1992
Force Engineering&Testing(TST5328) 117-0407T-09 UL 580 2006
UL1897 2012
Force Engineering&Testing(TST5328) 117-0407T-09A UL 580 2006
UL 1897 2012
Intertek-West Palm Beach(an ATI company) (TST1527) B9000.01-450-18 UL 580 2006
UL 1897 2012
Intertek-West Palm Beach(an ATI company) (TST1527) C0308.01-450-18 UL 580 2006
UL1897 2012
Intertek-West Palm Beach(an ATI company) (TST1527) D0818.01-450-18 UL 580 2006
Intertek-West Palm Beach(an ATI company) (TST1527) D1692.01-450-44 UL 580 2006
UL 1897 2012
ASTM E 8
Intertek-West Palm Beach(an ATI company) (TST1527) G7287.01-450-44 UL 580 2006
PRI Construction Materials Technologies(TST5878) 1272T0005 ASTM G 155 2013
PRI Construction Materials Technologies(TST5878) 2292T0001 UL 580 2006
UL 1897 2012
PRI Construction Materials Technologies(TST5878) 2292T0002
UL 580 2006
UL 1897 2012
PRI Construction Materials Technologies(TST5878) 2292T0011 UL 580 2006
UL 1897 2012
GCS20002.2a FL33818-R2 Page 2 of 6
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK GULF COAST SUPPLY&MANUFACTURING,LLC
Metal Roofing
TECHNICAL SERVICES. LLC
PRODUCT DESCRIPTION
GulfLok Profile: 1 in. snap lock seam: Max 16 in. coverage]
Description: Non-structural, snap lock standing seam roof panel with 7/8 in. slotted nail strip
Material: Min. 26 ga. ASTM A792 AZ50 or ASTM A653 G90; Optional Fluropon®paint
finish; Fy= min. 50 ksi; Shall conform with FBC Section 1507.4.3
Mm Q.032 in.ASTM B209, 3105 H24 aluminum;Optional Fluropon®paint finish;
F,,= min.24 ksi; Shall conform with FBC Section 1507.4.3
11
12" and 16" Coverage
GulfSeam I Profile:i 1 3/4 in. snap lock seam; Max. 18 in. coverage
Description: ! Non-structural, snap lock standing seam roof panel
Material: ' Min. 26 ga.ASTM A792 AZ50 or ASTM A653 G90; Optional Fluropon®paint
finish; F = min. 50 ksi; Shall conform with FBC Section 1507A.3
Min. 0.032-inch ASTM B209, 3105 H24 aluminum, Optional Fluropon®paint finish;
Ft= min. 21 ksi; Shall conform with FBC Section 1507.4.3
fur 11
14", 16",and 18"Coverage
MegaLoc Profile:1..._2in. mechanical seam; Max. 18 in.coverage ._....._.__..._..............____._...._..._..._......................._-.._
Description: ! Non-structural, mechanical lock 180°standing seam roof panel
Material: 1 Min. 24 ga.ASTM A792 AZ50 or ASTM A653 G90; Optional Fluropon®paint
i finish; Fy= min.50 ksi; Shall conform with FBC Section 1507A.3
9$
2" d ;
16 -fig-Coverage
GCS20002.2a FL33818-R2 Page 3 of 6
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK GULF COAST SUPPLY&MANUFACTURING, LLC
a? Metal Roofing
TECHNICAL SERVICES, LLC
VersaLoc Profile:11.5 in.mechanical seam; Max. 18 in. coverage
Description: I Non-structural, mechanical lock 180°standing seam roof panel
Material: Min.24 ga.ASTM A792 AZ50 or ASTM A653 G90; Optional Fluropon®paint
finish; Fy=min.50 ksi; Shall conform with FBC Section 1507.4.3
M
lin
16"•18"Coverage
5V Crimp Profile:7/16 in. ribs at 12 in. o.c.; 24 in.coverage
Description: Non-structural, through fastened roof panel
Material: i Min. 26 ga. ASTM A792 AZ50 or ASTM A653 G90; Optional Fluropon®paint
finish; Fy= min. 50 ksi; Shall conform with FBC Section 1507.4. 3
Min. 0.032 in.ASTM B209, 3105 H24 aluminum; Optional Fluropon®paint finish;
Fy= min.25 ksi; Shall conform with FBC Section 1507.4.3
7/161 12"
24" Coverage
GuIfPBR Profile: 1 1/4 in. ribs at 12 in.o.c.; 36 in.coverage
Description:1. Non-structural, through fastened roof pan&
Material: i Min. 26 ga. ASTM A792 AZ50 or ASTM A653 G90; Optional Fluropon®paint
finish; Fy= min.80 ksi; Shall conform with FBC Section 1507.4.3
11/41 12"
36"Coverage
GCS20002.2a FL33818-R2 Page 4 of 6
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK GULF COAST SUPPLY&MANUFACTURING, LLC
Metal Roofing
TECHNICAL SERVICES. LLC
GulfRib Profile: 3/4 in. ribs at 9 in.o.c.; 36 in. coverage
Description: Non-structural,through fastened roof panel
Material: Min. 29 ga. ASTM A792 AZ50 or ASTM A653 G90; Optional Fluropon®paint
finish; Fy= min. 80 ksi; Shall conform with FBC Section 1507.4.3
Netf 9"
36" Coverage
GulfWave Profile:i 3/4 in. corrugation;29 in.coverage
Description: i Non-structural,through fastened roof panel
Material: I Min. 26 ga.ASTM A792 AZ50 or ASTM A653 G90; Optional Fluropon®paint
I finish; Fy=min.80 ksi; Shall conform with FBC Section 1507.4.3
hf
3/4 1t
29" Coverage
GCS20002.2a FL33818-R2 Page 5 of 6
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
RING,LLC
J .._. CREEK GULF COAST SUPPLY&MANUFACMeUtal Roofing
TECHNICAL SERVICES, LLC
LIMITATIONS
1. Fire classification is not within the scope of this evaluation.
2. This report is not for use in the HVHZ.
3. The roof deck and the roof deck attachment shall be designed by others to meet the minimum design loads
established for components and cladding and in accordance with FBC requirements.
4. Roof slope shall be in accordance with FBC Section 1507.4.2.
5. Reroofing shall be in accordance with FBC Section 1511. Recovery versus replacement shall be evaluated
in accordance with FBC Section 1511.3.
6. Installation of the evaluated products shall comply with this report, the FBC and the manufacturer's
published application instructions. Where discrepancies exist between these sources, the more restrictive
and FBC compliant installation detail shall prevail.
7. All products listed in this report shall be manufactured under a quality assurance program in compliance with
Rule 61G20-3.
COMPLIANCE STATEMENT
The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building
Code, 7th Edition(2020)as evidenced in the referenced documents submitted by the named manufacturer.
RYR. Pt,", This item has been
P.•\G•E •NS'. cc-, digitally signed and 2021 .10.21F •. )‘ . sealed by Zachary R.
No 74021 Priest, PE,on 10/21/2021. 10:40:51
Printed copies of this M
p;
Z.' considered
document are not 04'00'
53%. STATE OF it/Z. considered signed and
0 4 sealed and the signatureA` ••'° p':••• %Zachary R. Priest, P.E.O R .O•• •% must be verified on any
SS' •" " .`electronic copies. Florida Registration No. 74021
ft, ON VS Organization No.ANE9641
CERTIFICATION OF INDEPENDENCE
CREEK Technical Services, LLC does not have, nor will it acquire,a financial interest in any company manufacturing or distributing
products under this evaluation.
CREEK Technical Services, LLC is not owned,operated,or controlled by any company manufacturing or distributing products under
this evaluation.
Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products
under this evaluation.
Zachary R.Priest, P. E.does not have, nor will acquire,a financial interest in any other entity involved in the approval process of the
product.
APPENDICES
1) APPENDIX A—Installation (5 pages)
2) APPENDIX B—Approved Roof Systems (7 pages)
3) APPENDIX C—Design Wind Loads (4 pages)
GCS20002.2a FL33818-R2 Page 6 of 6
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK GULF COAST SUPPLY&MANUFACTURING, LLC
Metal Roofing
TECHNICAL SERVICES. LLC
APPENDIX A
INSTALLATION
Note-Refer to the APPROVED ROOF SYSTEMS section of this report for specific installation details of a selected system.
Unless otherwise specified in this report the following installation details shall be met for the named products:
Component Product Installation Detail
9-15 HWH wood screw
with sealing washer
9-15 HWH WoodZAC
screw
10- 12 Pancake Type A
screw
10- 14 HWH WoodTite Shall penetrate through the sheathing a minimum 3/ 8 in. Shall be corrosion
Fastener with sealing resistant in accordance with FBC section 1507.4.4.
Fasteners washer
12-11 Pancake Type A
screw
12- 8 HWH Woodgrip
XG screw with sealing
washer
1/4-14 HWH ZAC Impax Installed at panel side lap;Shall be corrosion resistant in accordance with FBC
Lap screw section 1507.4. 4.
24 ga.in-seam clip
GulfLok Clip i7....
aii
T-------:--:
1-314° L
1 1
Clips
18 ga.in-seam clip
14i.Fixed Clip t
r- I
s,„,,,,,,,,,,,
c_, ,,,-,..„...„:
J,",,,,,
GCS20002.2a FL33818-R2 Page 1 of 5
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK GULF COAST SUPPLY&MANUFACTURING,LLC
Metal Roofing
TECHNICAL SERVICES. LLC APPENDIX A
Component Product Installation Detail
0. 78
4-1/4"
2"
NC-33003-3 Sliding Clip
I1JrElijOO
1/2"
o
Clips(Coned)
22 ga.top; 16 ga.base; in-seam clip
1500SC Sliding Clip
11ClfC
i
r d
TSealantsMetal
d rmaster
Shall be applied in 1/4"-5/16"continuous beads on the male rib along the seamMetalRoofSealant
Fastening Details
Nomenclature Attachment
1) #10-12 X 1" TYPE A PANCAKE
US x43 STAINLESS
GULF LOK PANEL STEEL RIVET 6"
OVERLAP SIDE) O C
J
ulfLok Ove,1aiS GULF LOK PANEL
IUNDERLAP SIDE!
PANCLIP SCREW
GCS20002.2a FL33818-R2 Page 2 of 5
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK GULF COAST SUPPLY&MANUFACTURING, LLC
Metal Roofing
TECHNICAL SERVICES. LLC
APPENDIX A
Fastening Details
Nomenclature Attachment
GulfLok'" CLIP 24 GA.
GulfLok Type 2
i
fr
1) #10- 12 X 1" TYPE A PANCAKE
Ga. Fixed Clipf
N
T
GulfSeam Type 1
j N
72) #10-12 Pancake Type A Per Clip.
N
MegaLoc Type 1 N
R'.
NC-33003 SLIDING CLIP I J
2) #10- 12 x 1" per Clip
AVriN
T
Versaloc Type 1 i
1500SC SLIDING CLIP
2) #12-11 x 1"Panhead per Clip
1 ) #9-15 x 1 -1 /2" HWH w/Sealing Washer
5V Type 1 12"1 2" q
At Panel Lap /
1 ) #9-15 x 1 -1 /2" HWH w/Sealing Washer
5VType2
fr 2" - 9.5" 1214r 9.5" g2"
rt it/Nt--
1
GCS20002.2a FL33818-R2 Page 3 of 5
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
4w.
CREEK GULF COAST SUPPLY&MANUFACTURING,LLC
Metal Roofing
TECHNICAL SERVICES, LLC
APPENDIX A
Fastening Details
Nomenclature Attachment
12"4r 12"
5V Type 3
At Panel Lap
1 ) #9-15 x 1 - 1 /2" HWH w/Sealing Washer
At Panel Lap
1/4-14 x 7/8"Lap Screw @ 24"O.C. Max.-----\
12" 12" ----------11- - 12" -
GuIfPBR Type 1
Th___—______—______/7-4_—
1) #9-15x 1-1/2"
1/4-14 x 7/8" Lap Screw @ 24"O.C. Max. -,,
0,_ 511. 0 7" 0,___ 5511711 .-.,.- 11'._-e'- '-_-_711 --_ -.. ,,\,51.---
7r
GuIfPBR Type 2 1
1
i_____
1) #9-15 x 1-1/2"
9" ---t-- 9"- 9" 9" r
At Panel Lap,
GulfRib Type 1
1
I l _
L(1)#9-15 x 1- 1/2"w/Sealer Washer
1 1—— r 2.5" 6.5" ¶ 2.5" i ---6.5"—--i-2.5"-+5' 5"--
GulfRib Type 2
Z(1)#9-15 x 1-1!2"w/Sealer Washer
GCS20002.2a FL33818-R2 Page 4 of 5
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
C R E E K GULF COAST SUPPLY&MANUFACTURING,LLC
Metal Roofing
TECHNICAL SERVICES, LLC
APPENDIX A
Fastening Details
Nomenclature Attachment
1
91,
GulfRib Type 3 4 f
9-15 x 2"w/Sealer Washer
At Panel Lap--7
9' 9 9"6.5" 2.5"-v
GulfRib Type 4 f I
1)#12-8 x 1-1/2"WoodGr p XG W/Sealer Washer
At Panel Lap
811 8" 8"5.33I
GulfWave Type 1
L (1) #9-15 x 1-1/2" HWH w/Sealing Washer
GCS20002.2a FL33818-R2 Page 5 of 5
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEKGULF COAST SUPPLY&MANUFACTURING,LLC
G Metal Roofing
TECHNICAL SERVICES. LLC
APPENDIX B
APPROVED ROOF SYSTEMS
The following notes shall be observed when using the assembly tables below.
1. Maximum Design Pressure(MDP)was calculated using a 2:1 margin of safety per FBC Section 1504.9.
2. Refer to LIMITATIONS and sections of this evaluation when using the table(s)below.
3. Refer to INSTALLATION section of this report for installation detail when the information is not explicitly stated for the selected assembly.
4. The on-center(o.c.)spacing given is the maximum allowable attachment spacing for the rated system.
5. The panel thickness or gauge is the minimum allowable.
6. Steel Deck shall be designed by others in accordance with FBC requirements and shall be minimum 22 ga(F,=min.40 ksi)Wide Rib Deck(Type WR)
conforming to ANSI/SDI-RD1.0& FBC.
7. Wood Deck shall be designed by others in accordance with FBC requirements and shall be minimum 15/32-inch thick APA Span-Rated plywood
sheathing at maximum 24-inch span.
Roof System Numbers and Definitions
LOK-W# GulfLok over Wood Deck New or Existin )
SEAM-W# GulfSeam over Wood or Existing)
MEGA-W# MegaLoc over Wood Deck(New or Existing)
VL-W# 1.5"VersaLoc over Wood Deck(new or Existing)
5V-W# 5V Crimp over Wood Deck(New or Existing)
PBR-W# GuIfPBR over Wood Deck(New or Existing)
RIB-W# GulfRib over Wood Deck(New or Existing)
WAVE-W# GulfWave over Wood Deck(New or Existing)
Approved Systems for GulfLok over Wood Deck(New or Existing)
System MDP
Deck Fire Barrier Underlayment Roof Panel Panel AttachmentNo. psf)
OPTIONALMin. 15/32 Min.0.032"Al GulfLok GulfLok Type 1 attachment with #10-12 x 1"
Uttfere;B-C plywood
Approved fire barrier As required per FBC Max. 16-inch coverage' Pancake Type A screws spaced 5-3/16 in.o.c. -65.5
or insulation
OPTIONAL
GulfLok Type 1 attachment with #10-12 x 1"
Min. 15/32 Min.0.032"Al GulfLok Pancake Type A screws spaced 5-3/16 in.o.c.LOK-W-2 Approved fire barrier As required per FBC 116
B-C plywood
or insulation Max. 16-inch coverage Titebond Weathermaster Metal Roof Sealant
applied to male rib.
OPTIONAL GulfLok Type 1 attachment with#10- 12 x 1"
Min. 15/32 Min.0.040"Al GulfLok Pancake Type A screws spaced 6 in.o.c.LOK-W-3 CDX plywood
Approved fire barrier As required per FBC Max. 16-inch coverage Female leg snap-fit to male leg with 93.5
or insulation
GulfLok Overlap
GCS20002.2a FL33818-R2 Page 1 of 8
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or
quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use,or other
product attributes that are not specifically addressed herein.
Either method will
meet the
requirements at
critical areas (3ft
lengths) from
ridges. MJones,
11.29.2022
r CREEK GULF COAST SUPPLY&MANUFACTURING, LLC
Metal Roofing
TECHNICAL SERVICES. LLC
APPENDIX B
Approved Systems for GulfLok over Wood Deck(New or Existing)
System Deck Fire Barrier Underlayment Roof Panel Panel Attachment
MDP
No. psf)
OPTIONAL GulfLok Type 1 attachment with#10-12 x 1"
Min. 15/32 26 ga. GulfLok Pancake Type A screws spaced 5-3/16 in.o.c.LOK-W-4 CDX plywood
Approved fire barrier As required per FBC Max. 16-inch coverage Titebond Weathermaster Metal Roof Sealant -121.75
or insulation
applied to male rib.
OPTIONALMin. 15/32 26 ga.,Grade 80 GulfLok GulfLok Type 1 attachment #10-12 x 1"LOK-W-5 B-C plywood
Approved fire barrier As required per FBC Max. 16-inch coverage Pancake Type A p screws spaced 5-3/16 in.o.c -
63.5
or insulation
Min. 15/ 32 OPTIONAL 26 ga.,Grade 80 GulfLok GulfLok Type 2 attachment with
LOK-W-6 B-C plywood Approved fire barrier As required per FBC Max. 16-inch coverage 10-12 x 1"Pancake Type A screws through -161
or insulation clip and spaced 5-3/16 in.o.c.
Min. 15/32 OPTIONAL 24 ga. GulfLok GulfLok Type 1 attachment with#10-12 x 1"LOK-W-7 Approved fire barrier As required per FBC 81.75B-C plywoodywood
or insulation Max. 16-inch coverage Pancake Type A screws spaced 10-1/4 in.o.c.
Min. 15/32 OPTIONAL
24 ga.GulfLok GulfLok Type 1 attachment with#10- 12 x 1"LOK-W-8 B-C plywood
Approved fire barrier As required per FBC Max. 16-inch coverage ' Pancake Type A screws spaced 5-1/8 in.o.c. -
96.75
or insulation
Approved Systems for GulfSeam over Wood Deck(New or Existing)
System
Deck Fire Barrier Underlayment Roof Panel Panel Attachment MDP
No. psf)
OPTIONALMin. 15/32 Min.0.032"PJ GulfSeam GulfSeam Type 1 attachmentSEAM-W-1 CDX plywood
Approved fire barrier As required per FBC Max. 16-inch coverage with stainless steel clips spaced 18 in.o.c.
60
or insulation
OPTIONALMin. 15/32 Min.0.032"Al GulfSeam GulfSeam Type 1 attachmentSEAM-W-2 CDX plywood
Approved fire barrier As required per FBC Max. 16-inch coverage with stainless steel clips spaced 6 in.o.c.
75
or insulation
OPTIONALMin. 15/32 Min.0.032"Al GulfSeam GulfSeam Type 1 attachmentSEAM-W-3 CDX plywood
Approved fire barrier As required per FBC Max. 18-inch coverage with stainless steel clips spaced 18 in.o.c.
86
or insulation
GCS20002.2a FL33818-R2 Page 2 of 8
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or
quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use,or other
product attributes that are not specifically addressed herein.
CREEKGULF COAST SUPPLY&MANUFACTURING,LLC
Metal Roofing
F TECHNICAL SERVICES. LLC APPENDIX B
Approved Systems for GulfSeam over Wood Deck(New or Existing)
System MDP
Deck Fire Barrier Underlayment Roof Panel Panel AttachmentNo. psf)
Min. 15/32
OPTIONAL Min.26 ga.GulfSeam GulfSeam Type 1 attachmentSEAM-W-4 CDX plywood
Approved fire barrier As required per FBC Max. 16-inch coverage with clips spaced 18 in.o.c.
60
or insulation
Min. 15/32 OPTIONAL Min.26 ga.GulfSeam GulfSeam Type 1 attachment
SEAM-W-5 CDX plywood
Approved fire barrier As required per FBC Max. 16-inch coverage with clips spaced 6 in.o.c.
75
or insulation
Min. 1x4 No.2
SYP wood
purlins spaced OPTIONAL Min.24 ga.GulfSeam GulfSeam Type 1 attachment with clips spacedSEAM-W-6 18 in.o.c. Approved fire barrier As required per FBC 93.5
Max. 16 inch coverage 18 in.o.c.over wood purlins
over or insulation
Min. 15/32
B-C plywood
Min. 15/32 OPTIONAL Min.24 ga.GulfSeam GulfSeam Type 1 attachmentSEAM-W-7 B-C plywood
Approved fire barrier As required per FBC Max. 18-inch coverage with clips spaced 24 in.o.c.
69.25
or insulation
Min. 15/32 OPTIONAL Min.24 ga.GulfSeam GulfSeam Type 1 attachment
SEAM-W-8 B-C plywood
Approved fire barrier As required per FBC Max. 18-inch coverage with clips spaced 12 in.o.c.
108.5
or insulation
Min. 1x4 No.2
SYP wood
purlins spaced OPTIONAL Min.24 ga.GulfSeam GulfSeam Type 1 attachment with clips spaced
SEAM-W-9 24 in.o.c. Approved fire barrier As required per FBC 114.25Max. 18-inch coverage 24 in.o.c.over wood purlins
over or insulation
Min. 15/32
CDX plywood
Min. 1x4 No.2
SYP wood
purlins spaced OPTIONAL Min.24 ga.GulfSeam GulfSeam Type 1 attachment with clips spaced
SEAM-W-10 12 in.o.c. Approved fire barrier As required per FBC Max. 18 inch coverage 12 in,o.c.over wood purlins 159.25
over or insulation
Min. 15/32
CDX plywood
GCS20002.2a FL33818-R2 Page 3 of 8
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or
quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use,or other
product attributes that are not specifically addressed herein.
C REEK GULF COAST SUPPLY&MANUFACTURING,LLCCF- Metal Roofing
TECHNICAL SERVICES. LLC APPENDIX B
Approved Systems for MegaLoc over Wood Deck(New or Existing)
System MDP
Deck Fire Barrier Underlayment Roof Panel Panel Attachment
No. psf)
Min. 15/32 OPTIONAL Min. 24 ga. MegaLoc MegaLocType 1 attachmentMEGA-W-1 B-C plywood
Approved fire barrier As required per FBC
Max. 18-inch coverage with clips spaced 24 in.o.c.
71
or insulation
Min. 15/32 OPTIONAL Min.24 ga.MegaLoc MegaLocType 1 attachmentMEGA-W-2 B-C plywood
Approved fire barrier As required per FBC Max. 18-inch coverage with clips spaced 12 in.o.c.
108.5
or insulation
Approved Systems for VersaLoc over Wood Deck(New or Existing)
System MDP
Deck Fire Barrier Underlayment Roof Panel Panel AttachmentNo. psf)
Min. 15/32
OPTIONAL Min.24 ga.VersaLoc VersaLoc Type 1 attachment
VL-W-1 B-C plywood
Approved fire barrier As required per FBC Max. 16-inch coverage with clips spaced 24 in.o.c.
59.75
or insulation
Min. 15/32 OPTIONAL Min. 24 ga.VersaLoc VersaLoc Type 1 attachment
VL-W-2 B-C plywood
Approved fire barrier As required per FBC Max. 16-inch coverage with clips spaced 6 in.o.c.
123.5
or insulation
Approved Systems for 5V Crimp over Wood Deck(New or Existing)
System Fire Barrier/ MDP
No. Deck Insulation Underlayment Roof Panel Panel Attachment psf)
OPTIONALMin. 15/32 Min.0.032"Al 5V Crimp 5V Crimp Type 1 attachment with#9-15 HWH wood5V-W-1 B-C plywood
Approved fire barrier As required per FBC
24-inch coverage screws with sealing washers spaced 12 in.o.c.
108.5
or insulation
OPTIONAL 5V Crimp Type 3 attachment with#10- 14 HWH
layer of WoodTite Fasteners with sealing washersOPTIONALASTMD3462Min.26 ga.5V Crimp into wood purlins installed 16 in.o.c.counter to the
5V-W-2
shingles over
Approved fire barrier As required per FBC 24-inch coverage structural supports and attached with 75
Min. 15/32 or insulation min.0.113"x 2-3/8"ring shank nails spaced 4 in.o.c.
B-C plywood beginning 1 in.from the edge
GCS20002.2a FL33818-R2 Page 4 of 8
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or
quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other
product attributes that are not specifically addressed herein.
GULF COAST SUPPLY&MANUFACTURING, LLCCREEKMetalRoofing
r" TECHNICAL SERVICES. LLC APPENDIX B
Approved Systems for 5V Crimp over Wood Deck(New or Existing)
System Fire Barrier/ MDP
No. Deck Insulation Underlayment Roof Panel Panel Attachment
psf)
OPTIONAL
Min. 15/ 32 Min.26 ga.5V Crimp 5V Crimp Type 3 attachment with#9-15 HWH wood5V-W-3 Approved fire barrier As required per FBC 94.25
B-C plywood
or insulation 24-inch coverage screws with sealing washers spaced 16 in.o.c.
OPTIONALMin. 15/ 32 Min.26 ga.5V Crimp 5V Crimp Type 1 attachment with#9-15 HWH wood5V-W-4 B-C plywood
Approved fire barrier As required per FBC 24-inch coverage screws with sealing washers spaced 12 in.o.c.
108.5
or insulation
OPTIONAL
Min. 15/32 Min.26 ga.5V Crimp 5V Crimp Type 2 attachment with#9-15 HWH wood5V-W-5 B-C plywood
Approved fire barrier As required per FBC 24-inch coverage screws with sealing washers spaced 16 in.o.c.
131
or insulation
Min. 15/32 OPTIONAL Min.26 ga.5V Crimp 5V Crimp Type 1 attachment with
5V-W-6 Approved fire barrier As required per FBC 9-15 HWH wood screws with sealing washers spaced 6 -156.5
B-C plywood
or insulation 24-inch coverage in.o.c.
Approved Systems for GuIfPBR over Wood Deck(New or Existing)
System Fire Barrier/ MDP
No.
Deck Insulation Underlayment Roof Panel Panel Attachment
Psi
OPTIONAL
GuIfPBR Type 1 attachment with#9-15 15 HWH WoodZAC
Min. 15/32 Min.26 ga.GuIfPBR screws spaced 24 in.o.c.PBR-W-1 B-C plywood
Approved fire barrier As required per FBC
36-inch coverage Laps fastened with 1/4-14 x 7/T HWH ZAC Impax Lap
60.5
or insulation screws spaced 24 in.o.c.
Min. 1x4 No.2
SYP wood GuIfPBR Type 1 attachment with#9-15 HWH WoodZAC
purlins spaced OPTIONAL Min.26 ga.GuIfPBR screws spaced 24 in.o.c.into wood purlins
PBR-W-2 24 in.o.c. Approved fire barrier As required per FBC 100.5
36-inch coverage Laps fastened with 1/4-14 x 7/8 ZAC Impax Lap screwsoverorinsulation
Min. 15/32 spaced 24 in.o.c.
B-C plywood
GCS20002.2a FL33818-R2 Page 5 of 8
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or
quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use,or other
product attributes that are not specifically addressed herein.
CREEK GULF COAST SUPPLY&MANUFACTURING, LLC
Metal Roofing
TECHNICAL SERVICES, LLC APPENDIX B
Approved Systems for GuIfPBR over Wood Deck(New or Existing)
System Fire Barrier/ MDP
No. Deck Insulation Underlayment Roof Panel Panel Attachment
psi
Min. 1x4 No.2
SYP wood GuIfPBR Type 2 attachment with#9-15 15 HWH
purlins spaced OPTIONAL Min.26 ga.GuIfPBR WoodZAC screws spaced 12 in.o.c.into wood purlins
PBR-W-3 12 in.o.c. Approved fire barrier As required per FBC 151.75
over or insulation 36-inch coverage Laps fastened with 1/4-14 x 7/8"HWH ZAC Impax Lap
Min. 15/32 screws spaced 24 in.o.c.
B-C plywood
OPTIONAL
GuIfPBR Type 2 attachment with#9-15 HWH WoodZAC
PBR-W-4 Min. 15/32 Approved fire barrier As required per FBC Min.26 ga.GuIfPBR screws spaced 12 in.o.c. 154.75
B-C plywood or insulation 36-inch coverage Laps fastened with 1/4-14 x 7/8"HWH ZAC Impax Lap
screws spaced 24 in.o.c.
Approved Systems for GulfRib over Wood Deck(New or Existing)
System MDP
Deck Fire Barrier/ Underlayment Roof Panel Panel AttachmentNo. Insulation psf)
OPTIONAL Min.29 ga.GulfRib GulfRib Type 4 attachment with#12-8 HWH Woodgrip XGRIB-W-1 Min.7/16 OSB Approved fire barrier As required per FBC 22.66
36-inch coverage wood screws with sealing washers spaced 24 in.o.c.or insulation
Min. 15/32
OPTIONAL Min.29 ga.GulfRib GulfRib Type 3 attachment with#9-15 HWH wood screwsRIB-W-2 CDX plywood Approved fire barrier As required per FBC 36-inch coverage with sealing washers spaced 24 in.o.c.
56
or insulation
Min. 15/32 OPTIONAL Min.29 ga. GulfRib GulfRib Type 1 attachment with#with#9-15 HWH
RIB-W-3 B-C plywood
Approved fire barrier As required per FBC 36-inch coverage WoodZAC screws spaced 24 in.o.c
71.75
or insulation
Min. 1x4 No.2
SYP wood
purlins spaced OPTIONAL GulfRib Type 1 attachment with#9-15 x 1 1/2"HWH wood
RIB-W-4 24 in.o.c. Approved fire barrier As required per FBC Min.29 ga. GulfRib screws with sealing washers spaced 24 in.o.c. 76.75
over or insulation 36 inch coverage into wood purlins
Min. 15/32
B-C plywood
GCS20002.2a FL33818-R2 Page 6 of 8
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or
quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other
product attributes that are not specifically addressed herein.
CREEK GULF COAST SUPPLY&MANUFACTURING, LLC
Metal Roofing
TECHNICAL SERVICES. LLC APPENDIX B
Approved Systems for GulfRib over Wood Deck(New or Existing)
System Fire Barrier/ MDP
No.
Deck Insulation Underlayment Roof Panel Panel Attachment psf)
Min. 1x4 No.2
SYP wood OPTIONAL GulfRib Type 1 attachment with#9-15 x 1 1/2"HWH wood
RIB-W-5 Purlins spaced Approved fire barrier As required per FBC
Min.29 ga.GulfRib
screws with sealing washers spaced 24 in.o.c. 101
24 in.o.c.
or insulation 36-inch coverage into wood purlins
over
Min.7/16 OSB
Min. 15/32 OPTIONAL Min.29 ga.GulfRib GulfRib Type 3 attachment with#9-15 HWH wood screwsRIB-W-6 CDX plywood
Approved fire barrier As required per FBC 36-inch coverage with sealing washers spaced 12 in.o.c.
101
or insulation
OPTIONAL Min.29 ga.GulfRib GulfRib Type 4 attachment with#12-8 HWH Woodgrip XGRIB-W-7 Min.7/16 OSB Approved fire barrier As required per FBC 116.0
36-inch coverage wood screws with sealing washers spaced 6 in.o.c.or insulation
Min. 1x4 No.2
SYP wood
purlins spaced OPTIONAL GulfRib Type 2 attachment with#9-15 x 1 1/2"HWH wood
RIB-W-8 24 in.o.c. Approved fire barrier As required per FBC Min.29 ga.GulfRib
screws with sealing washers spaced 24 in.o.c. 123.5
over or insulation 36-inch coverage into wood purlins
Min. 15/32
B-C plywood
Min. 15/32
OPTIONAL Min.29 ga.GulfRib GulfRib Type 2 attachment with#9-15 HWH wood screws
RIB-W-9 B-C plywood Approved fire barrier As required per FBC 36-inch coverage with sealing washers spaced 12 in.o.c.
146.0
or insulation
Min. 1x4 No.2
SYP wood
purlins spaced OPTIONAL Min.26 ga.GulfRib GulfRib Type 1 attachment with#9-15 HWH WoodZACRIB-W-10 24 in.o.c. Approved fire barrier As required per FBC 106.7536-inch coverage screws spaced 24 in.o.c.into wood purlins
over or insulation
Min. 15/32
B-C plywood
Min. 15/32
OPTIONAL Min.26 ga.GulfRib GulfRib Type 2 attachment with#9-15 HWH WoodZAC
RIB-W-11 B-C plywood
Approved fire barrier As required per FBC 36-inch coverage screws spaced 12 in.o.c. 159.25
or insulation
GCS20002.2a FL33818-R2 Page 7 of 8
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or
quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use,or other
product attributes that are not specifically addressed herein.
CREEK GULF COAST SUPPLY&MANUFACTURING, LLC
Metal RoofingillTECHNICALSERVICES. LLC
APPENDIX B
Approved Systems for GulfRib over Wood Deck (New or Existing)
System Fire Barrier/ MDP
No. Deck Insulation Underlayment Roof Panel Panel Attachment
psf)
Min. 1x4 No.2
SYP wood
purlins spaced OPTIONAL Min.26 ga.GulfRib GulfRib Type 1 attachment with#9-15 HWH WoodZACRIB-W-12 12 in.o.c. Approved fire barrier As required per FBC 36 inch coverage screws spaced 12 in.o.c.into wood purlins
164.25
over or insulation
Min. 15/32
B-C plywood
Approved Systems for GulfWave over Wood Deck (New or Existing)
System Fire Barrier/ MDP
No. Deck
Insulation
Underlayment Roof Panel Panel Attachment
psf)
Min. 15/32 OPTIONAL Min.26 ga.GulfWave GulfWave Type 1 attachment with
WAVE-W-1 B C
plywoodApproved
fire As required per FBC 9- 15 HWH wood screws with sealing washers 78.5
barrier or insulation 29-inch coverage spaced 24 in.o.c.
GCS20002.2a FL33818-R2 Page 8 of 8
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or
quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use,or other
product attributes that are not specifically addressed herein.
IA CREEK GULF COAST SUPPLY&MANUFACTURING,LLC
Metal Roofing
TECHNICAL SERVICES. LLC
APPENDIX C
DESIGN WIND LOADS
The following tables provide design wind loads for components and cladding in accordance with Section 1609 of the FBC and ASCE 7-16 under the following
provisions:
1. Wind speeds for risk category I, II, Ill, and IV buildings shall be as defined in Section 1609 of the FBC.
2. Exposure B,C,and D shall be as defined in section 1609 of the FBC.
3. Design wind load provided only for gable/hip roofs with roof slopes between 2:12 and 6.1:12
4. All calculations are based on an effective wind area of 10-ft2 or less.
5. Topographic factors such as escarpments or hills have been excluded from the analysis
6. Overhangs have been excluded from the analysis.
7. Wind directionality factor, Kd=0.85
8. V,,,t is shown in the tables below. Design wind loads are calculated using Vasd=V,,1t\'0. 6 per 1609.3.1.
9. Zone 2 is inclusive of Zone 2e,Zone 2n, and Zone 2r
10. Zone 3 is inclusive of Zone 3e and Zone 3r
11. Projects with mean roof heights greater than 60-ft shall be evaluated by a licensed design professional
12. Zones 1,2, and 3 shall be defined as shown below. Dimension"a"shall be 10%of the least horizontal dimension or(0.4 x Mean Roof Height), whichever
is smaller, but not less than either 4%of the least horizontal dimension or 3ft
Gable Hip
3 2 3 3 2 3 a 2 3# a
Nr.
2 1 2 2 1 2 2 1 2 2 2
31 2 3 3, 2 ' 3 a 3 2 3 a
lal gala lal lal lal
GCS20002.2a FL33818-R2 Page 1 of 4
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or
quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use,or other
product attributes that are not specifically addressed herein.
o `3ic0oJpXOM1 Ln N W O M M N Ln N V M N a m m O N N N O N O N m m N (O V N f ) (O N N mOOOOm m N m M .- (D (D V N N m O m r N• m C./ ^ M (n V m 0 0 h 46 In C pZNnwDaOQNCDO1- N- N M V N M M co co (D N 00 0 0 r- N- N N V Ln to co V O a n t y111111111111111111111111111 (00 ,D d d d 7.-5 Ov2doa)Q o'oLLV0.) 0') a m V 1- V M a N I `- v- N Ln N C./. 7 m 1" V M a cpZO16comcoNCr) mto Ln co EZmMco co M 10 Na V co O m -464 .a O .a n N M N N- (n N (O 00 co (D C2mm ^ n m m m O O N NN . . N M ' N co O m 0 0 N N M V N Cr) M V co m o fC0302J •J J OaNOM .-- m to Ln m co `- `- (O (D 00 (D Cr' st N N a) F,
D N Cp (O V N Cr) M Ln O a n U@Hoc0054o6mM4OOstaiO - N N M cD ^ 6 M „ M O O
4
N N O r N M V V Z
11111 11111111111 W.-
Q U C
U t m
L U 03JOVinNco. N m - m (O O co N
O m <n CO m V V O N N V co a0 Ln .- m a0 .- a0 00f-
9 In Ih N (D m V O h NO o0 N m o N m f- M I M m M O O
oi N M Y anLnLnTco .5 a0 . rn rn - a0 rn rn o r` oo a0 a0 T _ - cr.)
L W EW
E U c
ON- Z.N
O 0)
C 0- O N 00 O V O m m N V 00 .- M M N- V O M W .- 1- 00 O V O m .- N m O m .- m C a
co N co Ln m Ln 4 O (D O co OD (O N 8 N N- m m N M m M O (D O m N N- LU N @ XND - 1 / 99 (ncoco r ooaornr aorn - - ( 9L9WconoQrnrn - aornrn c u) o
N a) C
C ° 7 N
CDRI 0 O
m w
cr,co V O V co y
h V00 O v n Ih n co ( • 00 7 r
0
O CnmNV0 N n 6 m wv (h O 46 O N DO M m Mm co n n N 0 M a
N - M YINtLn U) Ln (O (O1iN- N- ONm ) 1- toLc n O (D DON- N00ODN- W00mm EE
aO N
To CCt O
F-O
O Op
CC co (vj
O m V .- V N V Ln N O m m N O C0 N- LO V N m N N. (D m Ln M m (O O (O N W N M N O M J y
V 1- m N Ln 1- O N- co m 0 N- co 00 N O co (n m N Ln co co co m co h (n V O co co LL 0 N7MM / I (n 19 L9 (c (q ( o (O 9 (q n n °4 Ln Ln (n (4 (4 ( 4 )` (q a0 a0 rn rcol_
N a)
a g
LUCC
C O O N1O O m nMO0D m V V O m N DOOLOn O DNW NC.
co m N M mm O M )- m M (O m n O Mh 07h m N n (h O N 4 m M O co 4 m V r: o rwO - NM M M ', / Ln n N NLnnD (On "; MIvfN (t7 n (D (DLnD (OCD O
ao
cC o
aa N
N
a) L
6• O V (n N- N N CO ,- m V, V, O ,- (O O0 O O V h W V OO M a N- n h .- N V M (D M N M 7.- C
N (f) 1- W M 1- O Ln 00 O4 1- m N O m N M 66 c; .- <1. 6 O466 hi 4 mcri (O r `)
N N M M M Y I I I Ln In (O M M (N M 7 1- (n U) (n ( n (O (O a .L
O O'D
C O 0)
O'- N
V LIN N
J @ p" 5-2;-13
J p)N N COQ) cl (On (OO N N M V (n (D N N
CO')
V (On (OD N N M .7 M (OD N N COQ) M- N (OO N N M V Ln (OD 0 07
E. J+rn a)
W O(U of
70 O N
W O O
W
No
r N M N Cr)y C
CI
Lii I;
U
U
W yQ
O N N h'
C
c OU (O O co (
a ( N
5 W r aW N
aa))
7
IL' m d V N2o
A CREEK GULF COAST SUPPLY&MANUFACTURING, LLC
Metal Roofing
TECHNICAL SERVICES. LLC
APPENDIX C
Gable/Hip Roofs in Exposure C(Roof slope between 2:12 and 12:12)
Mean Basic Wind Speed(mph)
Building Type Zone Roof
120 130 140 150 160 170 180 190 200Height(ft)
20 36.9 43.3 50.2 57.6 65.6 74.0 83.0 92.5 102.5
25 38.5 45.2 52.4 60.2 68.5 77.3 86.7 _ -96.6 107.0
1
30 40.2 47.1 54.7 62.8 71.4 80.6 90.4 100.7 111.6
40 42.6 50.0 58.0 66.6 75.8 85.6 95.9 106.9 118.4
50 44.7 52.4 60.8 69.8 79.4 89.7 100.5 112.0 124.1
60 46.3 54.4 63.0 72.4 82.3 93.0 104.2 116.1 128.7
20 53.8 63.2 73.2 84.1 95.7 108.0 121.1 134.9 149.5
25 56.2 66.0 76.5 87.8 99.9 112.8 126.5 140.9 156.1
Enclosed/ 30 58.6 68.8 79.8 91.6 104.2 117.6 131.8 146.9 162.8
Partially Open 2
40 62.2 73.0 84.6 97.2 110.5 124.8 139.9 155.9 172.7
50 65.2 76.5 88.7 101.8 115.9 130.8 146.6 163.4 181.0
60 67.6 79.3 92.0 105.6 120.1 135.6 152.0 169.4 187.7
20 64.0 75.1 87.1 99.9 113.7 128.4 143.9 160.3 177.7
25 66.8 78.4 90.9 104.4 118.8 134.1 150.3 167.5 185.6
3
30 69.7 81.7 94.8 108.8 123.8 139.8 156.7 174.6 193.5
40 73.9 86.7 100.6 115.5 131.4 148.3 166.3 185.3 205.3
50 77.5 90.9 105.4 121.0 137.7 155.5 174.3 194.2 215.2
60 80.3 94.3 109.3 125.5 142.8 161.2 180.7 201.3 223.1
20 43.2 50.6 58.7 67.4 76.7 86.6 97.1 108.2 119.9
25 45.1 52.9 61.3 70.4 80.1 90.4 101.4 113.0 125.2
1
30 47.0 55.1 64.0 73.4 83.5 94.3 105.7 117.8 130.5
40 49.9 58.5 67.9 77.9 88.6 100.1 112.2 125.0 138.5
50 52.3 61.3 71.1 81.7 92.9 104.9 117.6 131.0 145.2
60 54.2 63.6 73.7 84.7 96.3 108.7 121.9 135.8 150.5
20 60.1 70.5 81.8 93.9 106.8 120.6 135.2 150.6 166.9
25 62.7 73.6 85.4 98.0 111.5 125.9 141.2 157.3 174.3
Partially 30 65.4 76.8 89.0 102.2 116.3 131.3 147.2 164.0 181.7
Enclosed 2 40 69.4 81.5 94.5 108.5 123.4 139.3 156.2 174.0 192.8
50 72.8 85.4 99.0 113.7 129.3 146.0 163.7 182.4 202.1
60 75.4 88.5 102.7 117.8 134.1 151.4 169.7 189.1 209.5
20 70.2 82.4 95.6 109.7 124.8 140.9 158.0 176.0 195.1
25 73.3 86.1 99.8 114.6 130.4 147.2 165.0 183.9 203.7
3
30 76.5 89.7 104.1 119.5 135.9 153.5 172.0 191.7 212.4
40 81.1 95.2 110.5 126.8 144.3 162.9 182.6 203.4 225.4
50 85.0 99.8 115.8 132.9 151.2 170.7 191.4 213.2 236.2
60 88.2 103.5 120.0 137.8 156.7 177.0 198.4 221.0 244.9
GCS20002.2a FL33818-R2 Page 3 of 4
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or
quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other
product attributes that are not specifically addressed herein.
ill CREEK GULF COAST SUPPLY&MANUFACTURING,LLC
Metal Roofing
TECHNICAL SERVICES. LLC
APPENDIX C
fAr
Mean Basic Wind Speed(mph)
Building Type Zone Roof
120 130 140 150 160 170 180 190 200Height(ft)
20 44.3 52.0 60.3 69.2 78.7 88.8 99.6 111.0 123.0
25 45.9 53.9 62.5 71.7 81.6 92.1 103.3 115.1 127.5
1 30 47.5 55.8 64.7 74.3 84.5 95.4 107.0 119.2 132.1
40 50.0 58.7 68.1 78.1 88.9 100.4 112.5 125.4 138.9
50 52.1 61.1 70.9 81.3 92.5 104.5 117.1 130.5 144.6
60 53.7 63.0 73.1 83.9 95.5 107.8 120.8 134.6 149.1
20 64.6 75.8 87.9 100.9 114.8 129.6 145.3 161.9 179.4
25 67.0 78.6 91.1 104.6 119.0 134.4 150.7 167.9 186.0
30 69.4 81.4 94.4 108.4 123.3 139.2 156.0 173.9 192.6
y Open 40 72.9 85.6 99.3 114.0 129.7 146.4 164.1 182.9 202.6
50 75.9 89.1 103.3 118.6 135.0 152.4 170.8 190.4 210.9
60 78.3 91.9 106.6 122.4 139.2 157.2 176.2 196.3 217.6
20 76.8 90.1 104.5 119.9 136.5 154.0 172.7 192.4 213.2
25 79.6 93.4 108.3 124.4 141.5 159.7 179.1 199.5 221.1
30 82.4 96.8 112.2 128.8 146.6 165.4 185.5 206.7 229.0
40 86.7 101.8 118.0 135.5 154.1 174.0 195.1 217.4 240.8
50 90.3 105.9 122.8 141.0 160.5 181.1 203.1 226.3 250.7
60 93.1 109.3 126.7 145.5 165.5 186.8 209.5 233.4 258.6
20 51.8 60.8 70.5 80.9 92.1 103.9 116.5 129.8 143.8
25 53.7 63.0 73.1 83.9 95.5 107.8 120.8 134.6 149.2
1
30 55.6 65.3 75.7 86.9 98.9 111.6 125.1 139.4 154.5
40 58.5 68.7 79.6 91.4 104.0 117.4 131.6 146.6 162.5
50 60.9 71.5 82.9 95.1 108.2 122.2 137.0 152.6 169.1
60 62.8 73.7 85.5 98.1 111.7 126.0 141.3 157.5 174.5
20 72.1 84.6 98.1 112.6 128.2 144.7 162.2 180.7 200.2
25 74.8 87.7 101.7 116.8 132.9 150.0 168.2 187.4 207.6
Partially 30 77.4 90.9 105.4 121.0 137.6 155.4 174.2 194.1 215.1
Enclosed 2 40 81.4 95.6 110.8 127.2 144.8 163.4 183.2 204.1 226.2
50 84.8 99.5 115.4 132.4 150.7 170.1 190.7 212.5 235.5
60 87.4 102.6 119.0 136.6 155.4 175.5 196.7 219.2 242.9
20 84.3 98.9 114.7 131.7 149.8 169.1 189.6 211.3 234.1
25 87.4 102.6 118.9 136.5 155.4 175.4 196.6 219.1 242.7
3
30 90.5 106.2 123.2 141.4 160.9 181.6 203.6 226.9 251.4
40 95.2 111.7 129.6 148.7 169.2 191.0 214.2 238.6 264.4
50 99.1 116.3 134.9 154.8 176.2 198.9 223.0 248.4 275.2
60 102.2 120.0 139.1 159.7 181.7 205.1 230.0 256.2 283.9
GCS20002.2a FL33818-R2 Page 4 of 4
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or
quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use,or other
product attributes that are not specifically addressed herein.