Loading...
1120 OCEAN BLVD RERF23-0004 t"'r REROOF SHINGLE PERMIT PERMIT NUMBER cr.) RERF23-0004 :� CITY OF ATLANTIC BEACH ISSUED:��. 800 SEMINOLE ROAD 1/10/2023 `loy ATLANTIC BEACH. FL 32233 EXPIRES: 7/9/2023 MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION. ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES . ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY. !NOTICE: In addition to the requirements of this permit,there may be additional restrictions applicable to this property ;that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. JOB ADDRESS: PERMIT TYPE: i DESCRIPTION: VALUE OF WORK: 1120 OCEAN BLVD REROOF SHINGLE SHINGLE ROOF $16000.00 TYPE OF REAL ESTATE ZONING: BUILDING USE SUBDIVISION: CONSTRUCTION: I NUMBER: GROUP: 170285 0000 ATLANTIC BEACH COMPANY: ADDRESS: CITY: STATE: ZIP: FORD ROOFING SYSTEMS INC 3839 Millpoint Drive Jacksonville FL 32257 OWNER: ADDRESS: CITY: STATE: ZIP: JEFF CHARTRAND 1120 OCEAN BV ATLANTIC BEACH FL 32233-5740 WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. LIST OF CONDITIONS Roll off container company must be on City approved list . Container cannot be placed on City right-of-way. FEES DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT BUILDING PERMIT 455-0000-322-1000 0 $135.00 STATE DBPR SURCHARGE 455-0000-208-0700 0 $2.03 STATE DCA SURCHARGE 455-0000-208-0600 0 $2.00 TOTAL:$139.03 Issued Date: 1/10/2023 1 of 2 (4 ; l3uiiding Permit Application;, Updated 10/9/18 .City of Atlantic Beach Building Department **ALL INFORMATION _, r/" 800 Seminole Road, Atlantic Beach, FL 32233 HIGHLIGHTED IN GRAY }� ),� IS REQUIRED. Phone: (904) 247-5826rEmail: Building-Dept@coab.us Job Address: ( 1.26Oec�-t. 8j tV(�• Permit Number: R E ?....P-213 - 0 004, Legal Description 5-C:4- 16 -.25 - 2qe Goad Bei L2 81k4iRE# 1702$5 —0000 Valuation of Work(Replacement Cost) $ 16/ oe)0 Heated/Cooled SF Non-Heated/Cooled • Class of Work: ❑New ❑Addition ❑Alteration ❑Repair ❑Move DDemo ❑Pool ❑Window/Door • Use of existing/proposed structure(s): ❑Commercialesidential • If an existing structure, is a fire sprinkler system installed?: ❑Yes ❑N`—�• Will tree(s) be removed in association with proposed project? ❑Yes(must submit separate Tree Removal Permit) Ale—...... Describe in detail the type of work to be performed: . _It_; [e__ Re. qQe Florida Product Approval# I O I 24_ ) for multiple products use product approval form Propert Ownerl' Inform•tion 4-re-,<A) ^ �f Name 'f-4' Address l� Ceeu•A_ IJ j Aid. City L ,'C at G`,,G� State FL zip .�,Z.23 3 Phone 964- 759 9 8(t, 7 E-Mail r2 -)C •'i til,9 W �`j l .C'I '`o ma Owner or Agent(If Agent, Power of Attorney or Agency Letter Required) ContractorInformation —/ ,fin I Name of�pany F r d /vpr' - , $ mac` Qualif in A ent R T"'A4,...-a.� '7--' Address c91 CityState Office Phone 9•' 314 , "760 ? I Job Site C tact jJ�umber se------e--- /�L Zip 3�r2 State Certification/Registration #ice/3,276 9e E-Mail ... "---d r , �1 - ��wL Architect Name& Phone# �f ` Engineer's Name& Phone# Workers Compensation Insurer ;Ce-04-t,_ �ocr-,'e. & OR Exempt 0 Expiration Date /•2- 3//.2.5 Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all the laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS,TANKS, and AIR CONDITIONERS, etc. NOTICE: In addition to the requirements of this permit,there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE 0 . COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS - OU ' PROPERTY. IF YOU INTEND TO OBTAIN FINANCING NSUI,T WITH YOUR LEN e R OR • ATTOR _ EFORE RECO I YOUR N ICE OF COMMENCEME OL- (Signature of Owner or Agent) /411.- / •�� o .��or) (Signatu Con Signed and sworn to (or affirmed) before me this ..y of Si n i and sworn to (or affirm-•) bet. d. of _-S/`/" \ ,2/923 , by I- , ; !./rl,, , 0 G.•!-t,tly, .20;3 , by .t�'! < I_� i .r— (Si a�2t 1 8ER AAA ) g it 1 (Si .re .f o .r Notary Public .41;... ., JACOB MAUST State of Washington ', Netary mission=Pcblic StateHb212979 of Florida r# [ J Personally Known OR Commission 21033704 sonally Known OR ti.:4Com Produced Identification My Comm. Expires Oct 29, 2025 [ I Produced Identificati. MyComm,Expires Jan 3,2026 '? , Type of Identification: Type of Identification: Bon. :'-ouch National Notary Assn. DOL •GG3 -u32.—N-%33i—a _ NOTICE OF COMMENCEMENT State of Florida 170285-0000 Tax Folio No. County of Duval To Whom It May Concern: The undersigned hereby informs you that improvements will be made to certain real property, and in accordance with Section 713 of the Florida Statutes,the following information is stated in this NOTICE OF COMMENCEMENT. legal Description of property being improved: 5-64 16-2S-29E ATLANTIC BEACH LOT 2 BLK 44 Address of property being improved: 1120 OCEAN BLVD Atlantic Beach FL 32233 General description of improvements: Shingle Re Roof Owner: Jeff Chartrand Address: 1120 OCEAN BLVD Atlantic Beach FL 32233 O0�c--mzc Owner's interest in site of the improvement: m O o C 0 ocoo 9 n Oz Fee Simple Titleholder(if other than owner): 2 a -N o rLw Name: m o Contractor: Ford Roofing Systems Inc. o n o 0 Mo 0 Address: 3839 Millpoint Dr.Jacksonville, FL 32257 0 Po Telephone No.: (904)314-7671 Fax No: 0 D o cu' Surety(if any) 0 0 Address: Amount of Bond$ Telephone No: Fax No: (3) Name and address of any person making a loan for the construction of the improvements r- Name: Address: Phone No: Fax No: Name of person within the State of Florida,other than himself,designated by owner upon whom notices or other documents may be served: Name: Address: Telephone No: Fax No: In addition to himself, owner designates the following person to receive a copy of the Lienor's Notice as provided in Section 713.06(2)(b), Florida Statues. (Fill in at Owner's option) Name: Address: Telephone No: Fax No: Expiration date of Notice of Commencement(the expiration date is one (1)year from the date of recording unless a different date is specified): 02/15/2023 THIS SPACE FOR RECORDER'S USE ONLY OWN • C Xvin 44r �, p� Date: �/��,G /V. , Befo•- �r a this "`-9 t day'-i ' ,.. in the Countyof ?State PARMINDER KAUR Of F •a, as personally appeared / Notary Publicill_ State of Washington Notary Public at Large,State of Florida,' my o Duval. Commission# 21033704 My commission expires: `-/ My Comm. Expires Oct 29, 2025 Personally Known: or Produced Identification: 1) , C4-3‘---14 3 2.--7q—T 1 S—D NEMO I etc. Certificate of Authorization#32455 353 Christian Street, Unit#13 Oxford, CT 06478 (203)262-9245 ENGINEER EVALUATE TEST CONSULT EVALUATION REPORT BY FLORIDA P.E. GAF Evaluation Report 01506.01.08-R34 1 Campus Drive FL10124-R32 Parsippany,NJ 07054 Date of Issuance:01/03/2008 (800)766-3411 Revision 34:06/10/2022 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code. The product described herein has been evaluated for compliance with the 7th Edition(2020)Florida Building Code sections noted herein. DESCRIPTION: GAF Asphalt Roof Shingles for use in FBC non-HVHZ jurisdictions LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted herein and FBC 1507.2.7.1/R905.2.6.1 CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s)changes,the referenced Quality Assurance or production facility location(s)changes,or Code provisions that relate to the product(s)change. Acceptance of our Evaluation Reports by the named client constitutes agreement to notify NEMO ETC,LLC of any changes to the product(s),the Quality Assurance or the production facility location(s). NEMO ETC,LLC requires a complete review of its Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT:The Florida Product Approval Number(FL#) preceded by the words"NEMo P.E. Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety. INSPECTION: Upon request,a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 7. *••••" ••. Prepared by: •••'���� N j�M/4 ••• Digitally signed :•�� ••��CEivsF• F2••. by Robert This item has been digitally signed and sealed by NO. 59166 • Robert Nieminen,P.E. Printed copies of this document are not •• * * * ; Nieminenconsidered signed and sealed,and the signature ^/ ^/ must be verified on any electronic copies. ••4 •:• '•• Date: 2.06.1 0 Robert Nieminen,Florida P.E.59166,FBC ANE1983 . •%0 •, STATE OF LL� . 202 NEMO • ETC,LLC,Florida CA#32455 • O ••• F V ••••� ' •. l ORIOP.••G•1: '16:46.41 -04'00 ss! rva�� ••'' CERTIFICATION OF INDEPENDENCE: 1. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. NEMO ETC,LLC is not owned,operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen,P.E. are, in any way,the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. ©2018 NEMO ETC,LLC I NEMO etc. ROOFING SYSTEMS EVALUATION: 1. SCOPE: Product Category: Roofing Sub-Category: Asphalt Shingles Product Approval Method: Method 1,Option D-Codified Material, Evaluation by Engineer Compliance Statement: GAF Asphalt Roof Shingles, as produced by GAF, have demonstrated compliance with the following sections of the 7th Edition (2020) Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1507.2.4,R905.2.3 Material standard ASTM D1970 2015 1507.2.5,R905.2.4 Material standard ASTM D3462 2010 1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D3161 2016 1507.2.7.1, R905.2.6.1 Wind Resistance ASTM D7158 2019 1507.2.7.1,R905.2.6.1 Wind Resistance TAS 107 2020 3. REFERENCES: ENTITY EXAMINATION REFERENCE DATE PRI(TST 5878) ASTM D1970 GAF-324-02-01 2011-12-01 PRI(TST 5878) ASTM D3462 GAF-897-02-01 2018-11-08 PRI(TST 5878) ASTM D3462 GAF-898-02-01 2018-11-08 PRI(TST 5878) ASTM D3462 GAF-899-02-01 2018-11-15 PRI(TST 5878) ASTM D3462(IN-MV) 376T0133 2021-02-05 PRI(TST 5878) ASTM D3462(CA-S) 37670135 2021-02-05 PRI(TST 5878) ASTM D3462(IN-MV) 37670163 2021-04-20 UL(TST 1740) ASTM D3462 93NK6295 1993-11-29 UL(TST 1740) TAS 107 94NK9632 2000-03-29 UL(TST 1740) ASTM D3161 04NK30546 2005-03-10 UL(TST 1740) ASTM D3462,D3161 04NK22009 2005-05-06 UL(TST 1740) ASTM D3161, D3462 06CA35251 2006-10-18 UL(TST 1740) ASTM D3462 06CA31603 2006-12-01 UL(TST 1740) ASTM D3161,D3462 06CA41095 2006-12-27 UL(TST 1740) ASTM D3161 06CA31611 2007-04-04 UL(TST 1740) ASTM D3161 06CA61148 2007-04-09 UL(TST 1740) ASTM D3161,D3462 07CA31742 2007-11-08 UL(TST 1740) ASTM 03161,D7158,D3462 08CA06100 2008-03-13 UL(TST 1740) ASTM D3161,D3462 09CA10592 2009-03-26 UL(TST 1740) ASTM D3161,D3462 09CA06856 2009-05-15 UL(TST 1740) ASTM D3161,D7158,D3462 09CA27281 2009-08-27 UL(TST 1740) ASTM D3161,D7158,D3462 10CA35554 2010-03-05 UL(TST 1740) ASTM D3161,D7158,D3462 10CA13686 2010-05-15 UL(TST 1740) ASTM D3462 10CA11953 2010-10-29 UL(TST 1740) ASTM D3161,D7158,D3462 10CA53934 2011-03-31 UL(TST 1740) ASTM D3161,D7158,D3462 11CA48924 2011-10-22 UL(TST 1740) ASTM D3161,D7158,D3462 11CA47919 2011-12-03 UL(TST 1740) ASTM D3161,D7158,D3462 11CA48725 2011-12-09 UL,LLC. (TST 9628) ASTM D3462 12CA34891 2012-10-12 UL,LLC.(TST 9628) ASTM D3161 12CA38083 2013-02-26 UL,LLC.(TST 9628) ASTM 03161,D7158,D3462 4786875675 2015-07-27 UL,LLC. (TST 9628) ASTM 03161,D7158, D3462 4787434542 2016-05-17 UL,LLC.(TST 9628) ASTM D3161,D7158,D3462 4788717529 2016-09-09 UL,LLC.(TST 9628) ASTM D3161,D7158,D3462 4788198026 2017-11-28 NEMO ETC,LLC Evaluation Report 01506.01.08-R34 Certificate of Authorization#32455 7'EDITION(2020)FBC NON-HVHZ EVALUATION(Method 1D) FL10124-R32 GAF Asphalt Roof Shingles Revision 34:06/10/2022 Page 2 of 7 NEMO I etc. ENTITY EXAMINATION REFERENCE DATE UL,LLC.(TST 9628) ASTM D3161 4788698165 2018-11-09 UL,LLC.(TST 9628) ASTM D3161 4788669132 2018-12-13 UL,LLC.(TST 9628) ASTM D3161 4788891098 2019-02-14 UL,LLC.(TST 9628) ASTM D3161,D7158,D3462 4788932264 2019-08-16 UL,LLC.(TST 9628) ASTM D3161,D7158,D3462 4789115488 2019-10-03 UL,LLC.(TST 9628) ASTM D3161,D3462 4788959558 2019-10-17 UL,LLC.(TST 9628) ASTM D3161,D7158,D3462 4786508528 2019-11-01 UL,LLC.(TST 9628) ASTM D3161 4789132672 2020-10-27 UL,LLC.(TST 9628) ASTM D3161 4789732437 2021-04-15 UL,LLC.(TST 9628) ASTM D3462 4790002635 2022-01-26 UL,LLC.(TST 9628) ASTM D3161,D7158,D3462 4788198026 2022-05-23 UL,LLC.(QUA 9625) Quality Control Service Confirmation 2018-10-18 UL,LLC.(QUA 9625) Quality Control Florida BCIS Current 4. PRODUCT DESCRIPTION: TABLE 1:ASPHALT SHINGLE COMPONENTS TYPE PRODUCT DESCRIPTION MATERIAL PLANT(S) STANDARD sin*Starter Strip Shing starter strips for asphalt roof shingles ASTM D3462 CA-S,IN-MV ACCESSORY mineral-surfaced,fiberglass-reinforced,self- STARTER QuickStart®Peel&Stick Starter adhering SBS modified bitumen starter strip, ASTM D1970 CA-S STRIPS Roll nominal 9-inch x 33 ft roll,for use with asphalt shingles with exposure of 6-inch or less color-coordinated starter strips for use with StarterMatch°Starter Strip Grand Canyon°and Grand Sequoia®series ACCESSORY Shingles asphalt shingles. StarterMatch®are installed as ASTM D3462 CA-F STARTER the second starter for Grand Canyon®and STRIPS Grand Sequoia°series installations WeatherBlocker "Premium starter strips for asphalt roof shingles ASTM D3462 IN-MV Starter Strip Shingles Marquis WeatherMax® IN-MV fiberglass reinforced 3-tab asphalt roof Royal Sovereign® shingles ASTM D3462 AL,CA-F,FL,GA,IN-MV, PA,TX-D Camelot°II _ IN-MV Fortitude° PA Glenwood° IN-MV Grand Canyon° CA-F,IN-MV Grand Sequoia° CA-F,IN-MV Grand Sequoia°AS _ CA-F Timberline®AH AL,CA-F, IN-MC, PA Timberline°AS II TX-E ASPHALT Timberline°CS CA-F SHINGLES AL,CA-S,CA-F,FL,IN- fiberglass reinforced,laminated asphalt Timberline HD° roof shingles ASTM D3462 MC, MD, MN, PA,TX-D, _ TX-E _Timberline°Solar HD CA-F,CA-S, IN-MV AL,CA-F,CA-S, FL, IN- MC,MD,MN,PA,TX-D, TX-E Timberline°Solar HDZ® IN-MV Timberline°NS AL,CA-S,FL,IN-MC, _ MD, MN, PA,TX-D,TX-E Timberline Ultra HD® AL,CA S,IN MC,MN, PA,TX-E NEMO ETC,LLC Evaluation Report 01506.01.08-R34 Certificate of Authorization#32455 7i"EDITION(2020)FBC NON-HVHZ EVALUATION(Method 1D) FL10124-R32 GM Asphalt Roof Shingles Revision 34:06/10/2022 Page 3 of 7 NEMO I etc. TABLE 1(CONTINUED):ASPHALT SHINGLE COMPONENTS MATERIAL TYPE PRODUCT DESCRIPTION STANDARD PLANT(S) Timberline®UHD fiberglass reinforced,laminated asphalt AL,CA-S,IN MC,MN, ASPHALT roof shingles ASTM D3462 PA,TX-E Woodland® IN-MV SHINGLES Slateline'" fiberglass reinforced 5-tab asphalt roof ASTM D3462 IN MV shingle Seal-A-Ridge®AS ArmorShield® SBS-Modified IR Ridge Cap GA HIP& Shingles RIDGE fiberglass reinforced,hip and ridge ASTM D3462 SHINGLES asphalt roof shingles GA,IN-MV Timbertex®Premium Ridge Cap IN-MV Shingles 5. LIMITATIONS: 5.1 This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E.are,in any way,the Designer of Record for any project on which this Evaluation Report,or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC High Velocity Hurricane Zone jurisdictions (i.e., Broward and Miami- Dade Counties). 5.3 This Evaluation Report pertains to above-deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. 5.4 This Evaluation Report does not include evaluation of fire classification. Refer to FBC 1505 for requirements and limitations regarding roof assembly fire classification. Refer to FBC 2603 for requirements and limitations concerning the use of foam plastic insulation. 5.5 Wind Classification: Refer to Section 6 for installation requirements to meet wind classifications TABLE 2A:WIND CLASSIFICATIONS,ASPHALT SHINGLES PRODUCT FBC TABLE 1507.2.7.1 OR R905.2.6.1 Marquis WeatherMax® ASTM D3161(F)&ASTM 07158(H) Royal Sovereign® ASTM 03161(F)&ASTM D7158(H) Camelot®II ASTM D3161(F)&ASTM D7158(H) Fortitude® ASTM D3161(F)&ASTM D7158(H) Glenwood® ASTM 03161(F)&ASTM D7158(H) Grand Canyon® ASTM D3161(F)&ASTM D7158(H) Grand Sequoia® ASTM D3161(F)&ASTM D7158(H) Grand Sequoia®AS ASTM D3161(F)&ASTM D7158(H) Timberline®AH ASTM D3161(F)&ASTM D7158(H) Timberline®AS II ASTM D3161(F)&ASTM D7158(H) Timberline®CS ASTM D3161(F)&ASTM 07158(H) Timberline HD® ASTM D3161(F)&ASTM D7158(H) Timberline®Solar HD ASTM D3161(F)&ASTM D7158(H) 11111111.11111, ASTM D3161(F)&ASTM D7158(H) Timberline®Solar HDZ® ASTM D3161(F)&ASTM D7158(H) Timberline®NS ASTM D3161(F)&ASTM D7158(H) Timberline Ultra HD® ASTM 03161(F)&ASTM D7158(H) Timberline®UHD ASTM D3161(F)&ASTM D7158(H) NEMO ETC,LLC Evaluation Report 01506.01.08-R34 Certificate of Authorization#32455 7`"EDITION(2020)FBC NON-HVHZ EVALUATION(Method 1D) FL10124-R32 GAF Asphalt Roof Shingles Revision 34:06/10/2022 Page 4 of 7 NEMoIetc. TABLE 2A:WIND CLASSIFICATIONS,ASPHALT SHINGLES PRODUCT FBC TABLE 1507.2.7.1 OR R905.2.6.1 Woodland® ASTM D3161(F)&ASTM D7158(H) SlatelineT" ASTM D3161(F)&ASTM D7158(H) 5.5.1 Classification by ASTM D7158: ASTM D7158,Class H applies only to exposure category B or C and a building height of 60 feet or less. Calculations by a qualified design professional are required for conditions outside these limitations. Contact the shingle manufacturer for data specific to each shingle. TABLE 2B:WIND CLASSIFICATIONS,STARTER STRIPS AND HIP&RIDGE TYPE PRODUCT FBC TABLE 1507.2.7.1 OR R905.2.6.1 STARTER STRIPS ASTM D3161,Class F WeatherBlockerT"Premium Starter Strip Shingles ASTM D3161,Class F Seal-A-Ridge®AS ArmorShield®SBS-Modified IR Ridge Cap Shingles ASTM D3161,Class F HIP&RIDGE ASTM D3161,Class F SHINGLES ASTM D3161,Class F(sealant Timbertex®Premium Ridge Cap Shingles required,See Section 6) 5.6 All components in the roof assembly shall have quality assurance audit in accordance with F.A.C. Rule 61G20-3. Refer to the Product Approval of the component manufacturer for components that are produced by a Product Manufacturer other than the report holder on Page 1 of this Evaluation Report. 6. INSTALLATION: 6.1 GENERAL: 6.1.1 Roof deck, slope, underlayment and fasteners shall comply with FBC 1507.2 / R905.2 and the shingle manufacturer's minimum requirements. 6.1.2 Underlayment shall be acceptable to GAF and shall hold current Florida Statewide Product Approval,or be Locally Approved per Rule 61G20-3, per FBC Sections 1507.2.3, 1507.2.4 or R905.2.3. 6.1.3 Fasteners shall be in accordance with manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.1.4 GAF asphalt shingles are acceptable for use in reroof(tear-off)or recover applications, subject to the limitations set forth in FBC Section 1511 or R908 and GAF published installation instructions. 6.2 STARTER SHINGLES OR STARTER STRIP: 6.2.1 Installation of Pro-Start®Starter Strip Shingles,WeatherBlockerT" Premium Starter Strip Shingles and QuickStart® Peel &Stick Starter Roll shall comply with the GAF current published instructions. 6.3 ASPHALT SHINGLES: 6.3.1 Installation of asphalt shingles shall comply with the GAF current published instructions, using minimum four(4) nails per shingle in accordance with FBC 1507.2.7 or R905.2.6,with the following exceptions: Camelot® II, Grand Canyon®,Grand Sequoia®and Woodland® require minimum five(5) nails per shingle. SlatelineT" requires minimum six(6) nails per shingle. • NEMO ETC,LLC Evaluation Report 01506.01.08-R34 Certificate of Authorization#32455 7T"EDITION(2020)FBC NON-HVHZ EVALUATION(Method 1D) FL10124-R32 GAF Asphalt Roof Shingles Revision 34:06/10/2022 Page 5 of 7 • NEMO I etc. 6.3.2 The following depict nail-placement locations for GAF shingles designed with a 'target nail zone'. Where the roof slope exceeds 21 units vertical in 12 units horizontal,special methods of fastening are required. Contact the GAF for details. 6.3.2.1 Fortitude®,Timberline® - "-11 orro AH,Timberline®CS and Timberline® HDZ®;slopes _,. ,� c TARGET° NAIL ZONE 'l 2:12 up to 21;12, ZONA OBJETIVO DE CLAVADO STANDARD NAILING PATTERN: natety 6 7/8'(174 rnml from bottom of shinglein nailing areaas shown.Nails must not be expoced.Not for use on ,lo. , . 6.3.2.2 Fortitude®,Timberline® AH,Timberline®CS and Timberline® HDZ®;slopes 5131661r4'itO greater than 21:12 ° a 3--- - ' $mm 159 mmi FNHANCFD NAILING PATTERN - - ..1 nominal 6 (152 mm)from bottom of shingleabove the cut-outsas shown.Nails must not he exposed. 6.3.2.3 Timberline®Solar HDZ®; 40"11016 mm) slopes 2:12 up to 21:12. TARGET 17-1/8' • • •- --I NAIL ZONE (435 mm) . 19C0d- 243mm1 147 6.3.2.4 Timberline®Solar HDZ®; 40"(1016 mm) slopes greater than 21:12 _ ,.rmm:_ _ - .. -614' i. TARGET 17 1/8" ` • !:_ • •. • w +_ —r NAIL ZONE (435 mm) •11,,5 - 3,11 1190- 240mm1 147 1 NEMO ETC,LLC Evaluation Report 01506.01.08-R34 Certificate of Authorization#32455 7u1 EDITION(2020)FBC NON-HVHZ EVALUATION(Method 10) FL10124-R32 GAF Asphalt Roof Shingles Revision 34:06/10/2022 Page 6 of 7 NEMO I etc. 6.4 HIP&RIDGE SHINGLES: 6.4.1 Installation of Seal-A-Ridge® Ridge Cap Shingles shall comply with the GAF , current published instructions with a ,'" minimum two (2) nails, minimum 3/8- ''a". Nail inch head diameter located 6-7/8-inch \ \ / Clavo back from the exposed end and 0.5- -' Clouer inch from the edge. -- \`1�' ., 6.4.2 Installation of Seal-A-Ridge®AS Nail ArmorShield®SBS-Modified IR Ridge - Cap Shingles shall comply with the GAF current published instructions \\ ° with a minimum two(2) nails, ;,\ 100 minimum 3/8-inch head diameter, per . shingle located 5.25-inch back from ..,\ ` >. the exposed end and 1-inch from the \Ki��mn "�,�' `,so edge. \ „ , 6.4.3 Installation of Timbertex® Premium 11.5' 1 (292 mm) Sealant Ridge Cap Shingles shall comply with (25 mm) (251mm, senante GAF current published instructions (—'1 I--� Enduitd'htancheite with a minimum two (2) nails, minimum 3/8-inch head diameter, per shingle and beads of Henkel"Loctite PL Roof&Flashing Polyurethane Sealant". caHo 12 Clouer (305 mm) 9' (229 mm) 12' (305 mm) 7. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction to properly evaluate the installation of this product. B. MANUFACTURING PLANTS: Contact the named QA entity for manufacturing facilities covered by F.A.C.Rule 61G20-3 QA requirements. Refer to Section 4 herein for products and production locations having met codified material standards. 9. QUALITY ASSURANCE ENTITY: UL, LLC—QUA9625: (360)817-5512; *1,)ns@ul.com - END OF EVALUATION REPORT- NEMO ETC,LLC Evaluation Report 01506.01.08-R34 Certificate of Authorization#32455 7'EDITION(2020)FBC NON-HVHZ EVALUATION(Method 1D) FL10124-R32 GAF Asphalt Roof Shingles Revision 34:06/10/2022 Page 7 of 7