1209 Beach Avenue SURVEY 03.26.2021DocuSign Envelope ID: BD7209AF-3370-4C08-A157-73D03323D445
MAP SHOWING SURVEY OF
Q
LOTS 1, 2 AND 3, BLOCK 51, ATLANTIC BEACH CORPORATION, A REPLAT OF MAYPORT
00
I�•., Q N
TERMINAL COMPANY'S MAP AS RECORDED IN PLAT BOOK 6, PAGE 1
OF THE CURRENT
PUBLIC RECORDS OF DUVAL COUNTY, FLORIDA. TOGETHER WITH THOSE LANDS LYING
EASTERLY OF AND ADJACENT TO SAID LOTS 1, 2 AND 3, BLOCK 51,
EASTERLY
TO THE
o
EROSION CONTROL LINE OF THE ATLANTIC OCEAN AS RECORDED iN
PLAT BOOK
35,
GENERAL PROJECT N 0 T E S e
W
x
PAGES 59, 59A, AND 59B OF SAID PUBLIC RECORDS, AND BEING BOUNDED ON
THE
W
NORTH BY AN EASTERLY PROJECTION OF THE NORTH LINE OF SAID
LOT 3 AND
ON
W W
THE SOUTH BY AN EASTERLY PROJECTION OF THE SOUTH LINE OF SAID LOT 1.
THE ATTACHED DRAWINGS DESCRIBE PROPOSED ALTERATIONS TO A SINGLE FAMILY
Z
W Z
RESIDENCE AT 1209 BEACH AVENUE IN ATLANTIC BEACH, FLORIDA. ALTERATIONS WILL
W
W W UN
D.E.P. MONUMENT
OCCUR SEAWARD OF THE COASTAL CONSTRUCTION CONTROL LINE. A FIELD PERMIT
U
pC U � o
a � W
No. 72-81—A19
FOR THE PROPOSED WORK HAS BEEN ACQUIRED FROM THE FLORIDA DEPARTMENT OF
,� F
ENVIRONMENTAL PROTECTION.
QQp�W�
r
THE BUILDING DESIGN AS DESCRIBED HEREIN IS INTENDED TO BE COMPLIANT WITH
�" Z 7t
ZNGLE
l
14 40(���
ALL REQUIREMENTS OF THE FLORIDA BUILDING CODE, RESIDENTIAL— 7TH EDITION
� POINT
a
l
SCALE. 1" 20'
(FBC)' THE 2014 EDITION OF THE NATIONAL ELECTRIC CODE' THE 6TH EDITION OF
�+
I
—
c OPPOSITE R47
-i-I �
'10
THE NEPA 101 LIFE SAFETY CODE, THE 6TH EDITION OF FLORIDA FIRE PREVENTION
� Q•i
z
I�
10 rn
CODE, AND ALL PERTINENT ZONING REGULATIONS OF THE CITY OF ATLANTIC BEACH,
4
r-AFLORIDA.
ALL REQUIREMENTS OF THESE CODES, WHETHER REFERENCED HEREIN OR
0�
NOT, MUST BE OBSERVED THROUGHOUT THE CONSTRUCTION PROCESS.
4
,�"'
rn
I
D.E.P. CERTIFICATION: THESE DESIGN DRAWINGS ARE IN COMPLIANCE WITH STANDARDS
"'�
IROL
ESTABLISHED IN SECTION 62B-33.008 OF THE FLORIDA ADMINISTRATIVE CODE. THE
LOT 4
f'1
PIPE. N47 LEGI9LE
FIFE. NOT
SITE FALLS BETWEEN RANGE MARKERS DU R-045 AND DU R-046 BOTH SHOWING A
0 a.4'
100 YEAR STORM WAVE CREST ELEVATION OF 17.4 NGVD '29 OR 16.3 NAVD '88.
s
Q6,' (FIELD)
C
ALL BUILDING STRUCTURE IS TO BE PLACED ABOVE THAT ELEVATION. ALL GRADE
IIf
y
237.7--a2
��
X 7.45 6 WOOD F NICE
w
G7
;
REFERENCES IN THESE DRAWINGS ARE MEASURED RELATIVE TO NAVD'88,
o
1
40"E
83.214G"�
�,
I
I
THE STRUCTURE WILL COVER LAND DESIGNATED AS FLOOD ZONE X PER THE
I
FOUND 112" tiRflN
g' WODO FENCE
COT
0Ln
.S
��
n
"'
(]
ENCLOSED SURVEY.
PIPE. NO CAP
D.
10.88
ROCK WALL 1
h>
ip
WOOD DEQ TSIl CCHE tp
p
l
�r
A
�
WALK44
��
�
ZONING INFORMATION:
i
BRIC9
'
TILE POOL. DECK
°= °' 15g
N
c`
-� SPA
s.ism
WOOD wA+� �4�
�g�
THE BUILDING DESCRIBED HEREIN IS AN EXISTING TWO STORY, SINGLE FAMILY
�� wAu
�
ArG�{
RESIDENCE RESTING ON LOTS 1, 2 AND 3, BLOCK 51, ATLANTIC BEACH
0p
AIc$
+
PO O� ta.�
�¢s-- -- r
p �
0
CORPORATION, A REPLAT OF MAYPORT TERMINAL COMPANY'S MAP AS RECORDED IN
b0
13iI
PAL}
of
s.0
Two STORY FRAME
1Sa. 12a�
..
PLAT BOOK 6, PAGE 1 OF THE CURRENT PUBLIC RECORDS OF DUVAL COUNTY,
..�..
Q1
W
.6 , 2.0' 2s.1 V
12rn
TWO S-fORY r�
N RESIQENCE
iiLEWALK 0. _— —��
o
FLORIDA TOGETHER WITH....
THE PROPERTY IS ZONED RS -1, ALL BUILDING SETBACK DIMENSIONS HAVE NOT
Q
-Pb`'
zo
FRAME W
GARAGE/
���RESiDENCF-
LOT }
:fi
CHANGED AND ALL RELATED REQUIREMENTS HAVE BEEN MET. MAXIMUM BUILDING
O
HEIGHT HAS NOT CHANGED AND REMAINS LESS THAN 35' ABOVE ANY CONSERVATIVE
0
>
n•"
soDVFs�
2.9'
� ---
1.s FOUND t12'IRa�a
` X72
ESTIMATION OF AVERAGE GRADE.
d Q
p
z+i.t. f 1
yC 14.01
ROCK WALL 9'J
PIPE'
ANY FILL DERIVED FROM NEW FOOTING EXCAVATIONS OR WALKWAY MANIPULATION WILL
C
A �.
0
BRICK wAL� 27.z'
BE PLACED IMMEDIATELY ADJACENT TO THE WORK AREA. ANY ADDITIONAL STRUCTURAL
Q'
L)cA1�
9R1CK WALK sp,,
�acK WALL fl.9'
�
� �
FILL REQUIRED WILL MEET FLDEP REQUIREMENTS FOR SOIL TYPE.
���++++
PROPOSED IMPERVIOUS SITE COVERAGE IS LESS THAN 45% OF TOTAL SITE AREA. IT
W
a ri
I.
WeLLPLl1AP
6D
l�
HAS INCREASED OVER EXISTING COVERAGE BY LESS THAN 250 SF SUCH THAT NO
OQ
p
a
HOUSE I
51.69' ROCK WA L
�'45"W 239.
S83 2, L FIELD)
0
IIa
STORM WATER RETENTION IS REQUIRED. EXISTING DRAINAGE PATTERNS HAVE NOT
0.5
,
�.
S83.21 4s VN 237.7
CHANGED. SEE SHEET 1.2 FOR COVERAGE NOTES.
FpUHD 1 /2" IRON iNO
CAP 0
O
z
EXISTING TREES WILL BE REMOVED OR REPLACED.
PIPE. NO
STREET
BUILDING INFORMATION:
7
I+I
r� ��,,,,, ROAD
� �WAI
NOTES-
nl
PAVED pLjBUC
O
l �z
�`
40' R0AT
a
a
THE PROPOSED BUILDING OCCUPANCY IS TO BE SINGLE FAMILY RESIDENTIAL, GROUP
(�
1. THIS IS A BOUNDARY SURVEY.
+cst
�
�
R-3.
2. BOUNDARY INFORMATION SHOWN HEREON IS BASED ON
THIS FIRM, JOB NO. 2014-0139 DATED FEBRUARY 7, 2D14.
SURVEY BY
� t
l
r Q l
THE PROPOSED CONSTRUCTION TYPE IS HERE CONSIDERED TYPE V—B. EXISTING
3. NO BUILDING RESTRICTION LINE AS PER PLAT.
m�m
00CONTINUOUS
IMPERVIOUS:
FLOORS AND WALLS ARE WOOD FRAME OVER A PERIMETER STEM WALL WITH
4. THE EROSION CONTROL LINE SHOWN HEREON HAS BEEN ESTABLISHED
AS THE SEAWARD BOUNDARY of ALL OCEANFRONT PROPERTY IN DUVAL
�
HOUSE = 1,780 SQUARE FEET
FOOTINGS AND ISOLATED INTERNAL PIERS. THE PROPOSED ELEVATOR
COUNTY, FLORIDA.
z -x
�
o
�
GARAGE = fi18 SQUARE FEET
ADDITION WILL REST ON A MONOLYTHIC CONCRETE SLAB AND FOOTING. THE ROOF IS
5. EROSION CONTROL LINE BASED ON STATE PLANE COORDINATES
AS
o
.�
HARDSCAPE = 4,353 SQUARE FEET
AND WILL BE CONVENTIONALLY FRAMED WOOD. THE WORK DESCRIBED HERE IS
O
RECORDED IN PLAT BOOK 35, PAGES 59 — 59B.r'
r
lj
WOOD = 1,075 SQUARE FEET
CONSIDERED TO CONSTITUTE A LEVEL 2 ALTERATION PER FBC SUCH THAT ALL NEW
— AR FEET
TOTAL IMPERVIOUS -11,510 SQUARENOT
WORK WILL MEET CURRENT CODE REQUIREMENTS BUT THE EXISTING STRUCTURE WILL
BE MODIFIED TO MEET CURRENT CODE REQUIREMENTS. SEE STRUCTURAL
OPpn TE HR -48
LOT SIZE=17,885 SQUARE FEET
DRAWINGS FOR STRUCTURAL DETAIL.
0
PERCENTAGE OF IMPERVIOUS=43.8%
NO PROPOSED WORK WILL VIOLATE ANY PREVIOUSLY ISSUED PERMITS OR ADVANCE
i
THE SEAWARD LIMITS OF THE EXISTING STRUCTURE. THE PROPOSED WORK IS NOT
CONSIDERED A SUBSTANTIAL IMPROVEMENT TO THE EXISTING STRUCTURE. THE
MATERIAL COST OF THE WORK IS CONSIDERED TO BE LESS THAN 50% OF THE
MARKET VALUE OF THE EXISTING STRUCTURE. NO NEW EXTERIOR LIGHTING WILL BE
;�
ADDED.
I�
ANGLE POINT
THIS SURVEY WAS MADE FOR THE BENEFIT OF
THE PROPERTY DESCRIBED HEREON LIES IN FLOOD ZONESl
"X" (AREA OF MINIMAL FLOOD HAZARD) AND COASTAL
oP�osITE-4g
ss�•58'2s" z2s.1i'
I
_ --o Q.E.P. MONUMENT
No. 72-81—A20
JUDITH S. BEAUBOUEF.
PROPOSED PROJECT SCOPE INCLUDES:
N
FLOODPLAIN ZONE "VE" (EL 12 FEET) AS WELL
AS CAN BE
s
DETERMINED FROM THE FLOOD INSURANCE RATE MAP
1. THE REMOVAL OF SOME EXISTING WINDOWS AND KITCHEN CABINETS. EXISTING
WE
(D
NUMBER 12031CO409J REVISED NOVEMBER 2, 2018
FOR
ROOF OVERHANG WILL BE CUT BACK IN PLACES.
DUVAL COUNTY, FLORIDA.
2. THE INSTALLATION OF A NEW ELEVATOR TO BE HOUSED IN A STRUCTURAL
JASON D. BOATWRIGHT, P.S.M.
ADDITION TO THE HOUSE. THE FOOTPRINT OF THE ADDITION WILL BE
S
"NOT VALID WITHOUT THE SIGNATURE AND THE ORIGINAL
FLORIDA LICENSED SURVEYOR and MAPPER No. LS 7292
APPROXIMATELY 36 SF. A NEW ROOF WILL COVER THE ADDITION AND EXTEND
SEAL OF A FLORIDA LICENSED SURVEYOR AND MAPPER."
FLORIDA LICENSED SURVEYING & MAPPING BUSINESS No. LB 3572
BACK OVER THE EXISTING HOUSE ROOF TO TIE INTO IT. ALL NEW MATERIALS
WILL MATCH THOSE EXISTING. ALL NEW WATERPROOF MEMBRANES AT ROOF AND
10' 20' 40
CHECKED BY:
FILE: 2021-0286
DRAWN BY: DAF
BOATWRIGHT LAND SURVEYORS, Inc. 150❑ ROBERTSDRIVE, JACKSONVILLE BEACH, FLORIDA241-8550 ���: MARCH 2s, 2021
SHEET 1 OF 1
WALLS WILL BE PROPERLY FLASHED AND MARRIED TO EXISTING IN ORDER TO
MAINTAIN THE INTEGRITY OF THE BUILDING ENCLOSURE ENVELOPE.
DRAW NG INDEX:
EXISTING
SURVEY
AND
PROJECT
ARCHITECTURAL DRAWINGS:
NOTES
SHEET 1.0= EXISTING SURVEY AND PROJECT NOTES
SHEET 1 .1 = SITE PLANS
SHEET 2.0= FIRST FLOOR PLANS
SHEET 3.0= SECOND FLOOR AND ROOF PLANS
10
SHEET 4.0= BUILDING ELEVATIONS
•
SHEET 5.0= WALL SECTION AND DETAILS
06-04-21
SHEET 6.0= ELEVATOR DETAILS
STRUCTURAL DRAWINGS:
SHEET S-1= FOUNDATION PLAN AND WALL SECTION
,��.•�.�,,�••.,�
SHEET S-2= FRAMING DETAILS
`'�`
Docu Signed by: -
SHEET S-3= GENERAL NOTES
90C3D8g9746D ...;
T-9
�. 6/4/2021 G