1291 Beach Avenue SURVEY 03.01.2018A/C. -AIR CONDITIONER ON PAD
BAL. = BALCONY
B.O.H.= BUILDING OVERHANG/EAVE
FND. = FOUND.
S. F.N.F. = SEARCHED FOR NOTHING FOUND
ESM'T. = EASEMENT
CONC. = CONCRETE
COV. = COVERED
CO. = COUNTY
D.W. = DRIVEWAY
S/W = SIDEWALK
TR. = TRAIL
ST. = STATE
C.M. = CONCRETE MONUMENT
i = CENTERLINE
I = BOUNDARY LINE
I = PROPERTY LINE
9.= FLOW LINE
DEGREE OF ARC
L = ANGLE
MORE OR LESS
1 3 T H S T
ABBREVIATION & SYMBOL LEGEND
D)= DEED
P) = PLAT
FM) = FIELD MEASURED
FEMA = FEDERAL EMERGENCY MANAGEMENT AGENCY
MON. = MONUMENT
I.P. = IRON PIPE
I.R. =IRON ROD
A = DELTA ANGLE
CHD. = CHORD
C.B. = CHORD BEARING
A = ARC LENGTH
R = RADIUS
R) = RADIAL
N.R.) = NON -RADIAL
R/W = RIGHT OF WAY MARGIN
W) = WITNESS
F.F.E. = FINISH FLOOR ELEVATION
F.P.& L = FLORIDA POWER AND LIGHT
I.E.A. = JACKSONVILLE ELECTRIC AUTHORITY
1.E.A.E. =JACKSONVILLE ELECTRIC AUTHORITY
EASEMENT
N83'35'36"E
OCEAN AVEN
J.E.A.E.E. -JACKSONVILLE ELECTRIC AUTHORITY
EQUIPMENT EASEMENT
C,E.C.= CLAY ELECTRIC CO-OPERATIVE
C.C.U.A. = CLAY COUNTY UTILITY AUTHORITY
B.M, = BENCH MARK
B.R.L. BUILDING RESTRICTION LINE
J.W.L. =JURISDICTIONAL WETLANDS LINE
T.B.M. =TEMPORARY BENCH MARK
U.D. = UNDERDRAIN
U.G. = UNDERGROUND
U.D.E. = UNOBSTRUCTED DRAINAGE EASEMENT
U.G.E. - UNDERGROUND ELECTRIC
P.P. = POWER POLE
P.B. = PLAT BOOK
PG. = PAGE
U.P.= UTILITY POLE
G.P.S. = GLOBAL POSITIONING SURVEY
G.I.S. = GEOGRAPHIC INFORMATION SYSTEM
LAT. = LATITUDE NORTH
LON. = LONGITUDE WEST
P.C.C. = POINT OF COMPOUND CURVE
j GU(ANCHDR [2 UTI LITY METER AS NOTED 7 FOUND CONCRETE MONUMENT AS NOTED L FIRE HYDRANT 0 WELL
Q POWER POLE 0 FOUND SURFACE MONUMENT 1) SET REM &CAP, IS NO. 4257 iY FIRE DEPARTMENT CONNECTION OVERNEABPOWERUNE
POWER TRANSFORMER p FOUND CORNERS AS NOTED—_—
x FE CE '
E- W —
WATER METER
WATER VALVE ADJACENT PROPEIM UNE
Y LIGNf POST R CENTEWNE EN sR.O.W.
MAP SHOWING BOUNDARY SURVEY OF:
LOT 11 AND LOT 17, BLOCK 51, ATLANTIC BEACH, ACCORDING TO THE MAP OR PLAT THEREOF RECORDED IN PLAT BOOK 6, PAGE 1 OF THE CURRENT PUBLIC RECORDS OF DUVAL COUNTY FLORIDA.
CORNER MONUMENT NOTE:
RECOVERED CORNERS ARE 1/2" IRON PIPES WITH NO CAP IDENTIFICATION UNLESS OTHERWISE NOTED.
CORNERS SET ARE 1/2" IRON RODS WITH CAP I.D. OF "PORTER-4257-
I
R E E T
INTERSECTION
308.52
AT S. W.
FROM 2" I P'. " IRON PIPE iFM
AND
13TH
STREET TO "12
I
307.5' (P)
1
I
I
i
N
I
I
I O
I
I
I
I
I
I
I
RECOVERED
112' IRON
PIPE, CAP I.D. ILLEGIBLE
F.E.M.A. = FEDERAL EMERGNCY MANAGEMENT
AGENCY
P.T. - POINT OF TANGENCY
P.O.B. = POINT OF BEGINNIfG
P.O.C. = POINT OF COMMErEMENT
P.I. =POINT OF INTERSECTIOI
P.R.C. = POINT OF REVERSE NRVE
P.R.M. = PERMANENT REFEENCE MONUMENT
P.C.P. = PERMANENTCONTOL POINT
P.K.N. = PARKER KALON NAI
P.L.S. = PROFESSIONAL LANISURVEYOR
T.O.B. = TOP OF BANK
B.O.B. = BOTTOM OF BANK
E.O.W. = EDGE OF WATER
M.N. = MAGNETIC NAIL
M.T.S. = MINIMUM TECHNIA_ STANDARDS
NGVD29 = NATIONAL GEODMC VERTICAL DATUM OF
1929
NAVD88 = NORTH AMERICAI VERTICAL DATUM OF 1988
X" - X -CUT IN CONCRETE
XFMR - TRANSFORMER
H = HORIZONTAL
V • VERTICAL
F.B. = FIELD BOOK
F.N. = FIELD NOTES
M
12
a
Fu
r
4
C
s•
20' 0 20 40'
1 "=20'
fi-- N'-7- E 122'+1_
I \
OI ` C
TVVE N pLp AT
p,ND y 1 z
LANDSBE
vV NTFP- L1I iE _ - l
ORDINARY
I
HIGH
m
E
130' (
FM)
N83'27'41
1
1
1 1
1
I '
MR
C)
M
o
z
RECEIVED
SEP 14 2018
BUilding DepartmentIHEREBYACERTIFYTO: City Of Atlantic Beach, FL
CHRIS HIONIDES
THAT THE LANDS HEREIN WERE SURVEYED UNDER MY RESPONSIBLE SUPERVISION AND
DIRECTION, THAT THERE ARE NO OBSERVABLE ABOVE GROUND ENCROACHMENTS EXCEPT
AS SHOWN, AND THAT THE SURVEY SHOWN HEREON MEETS THE MINIMUM TECHNICAL
STANDARDS SET FORTH BY THE FLORIDA BOARD OF PROFESSIONAL SURVEYORS AND
MAPPERS PURSUANT TO CHAPTER 472.027 / CHAPTER SJ-17.FLORIDA, STATUTES.
SURVEY NOTES: OFFICE COPY
1. BASIS OF BEARINGS: FIELD MEASURED BEARINGS REFER TO THE FLORIDA STATE PLANE GRID SYSTEM, EAST ZONE 901, NAD83, IN U.S. SURVEY FEET.
DEED BEARINGS ARE REFERENCED AND SHOWN AS (D). PLAT BEARINGS (IF ANY) AND DISTANCES ARE REFERENCED AND SHOWN THUS (D).
p000000002. UNDERGROUND UTILITIES AND/OR FOUNDATIONS, OR PLUMBNESS OF WALLS SERVING THIS OR ADJACENT PROPERTIES HAVE NOT BEEN LOCATED, SHOWN, OR p0 Op
DETERMINED. o° P 000
3. THERE MAY BE ESMT'S & CONDITIONS OF RECORD & NOT PART OF THIS RECORDED PLAT THAT HAVE NOT BEEN LOCATED OR SHOWN, WHICH MAY OR MAY o° 000000 ®
Ao0
NOT AFFECT THE SUBJECT PROPERTY. o ° ®$®
o
o v o
4. THIS SURVEY IS TO BE CONSIDERED INVALID IF MAP DOES NOT HAVE SURVEYORS ORIGINAL SIGNATURE AND AN EMBOSSED RAISED SURVEYORS 0
SEAL.
oo
CSD 0 , 4257 . o oS. LAST DATE OF FIELD SURVEY IS MARCH 1, 2018. LEGAL DESCRIPTION FURNISHED BY CLIENT AND NO ATTEMPT HAS BEEN MADE TO RESEARCH THE o TAS o 0 0
PUBLIC RECORDS FOR OTHER MATTERS OF TITLE. o c o o
6. THIS PROPERTY IS LOCATED IN FEMA FLOOD ZONE "A0-2 FOOT DEPTH" & "VE-ELEV. 14.0 [NAVD88)" AS DEPICTED ON FEMA FLOOD INSURANCE MAP
NO. 12031CO409H, DATED JUNE 3, 2013. oo STATE® o ® o
7. NO ATTEMPT HAS BEEN MADE TO LOCATE OR DETERMINE THE STATUTE ORDINARY HIGH WATER LINE, JURISDICTIONAL LANDS OF THE STATE OR
o
o0
0°
0
oSOVEREIGN, NOR HAS THIS SURVEYOR MADE A DETERMINATION OF THE OWNERSHIP OF FENCES OR UTILITIES. o o°
0
0
8. ELEVATIONS SHOWN HEREON ARE BASED ON GPS OBSERVATIONS USING THE TRIMBLE VIRTUAL REFERENCE NETWORK SOFTWARE AND A SPECTRA BO o ® °oOZ, 0R !`O- C°
GPS RECEIVER HAVING AN OBSERVATION PDOP 1.6 AND A VERTICAL PUBLISHED ERROR OF +/- 0.05'. gyp° ® °°0°0°0°
00
SURVEYED BY: CP F.N. NO. 218062 PG'S 1-2 DRAWN BY: CEP CHECKED BY: CEP ORIGINAL MAPPING DATE: 03/02/2018
SURVEY AND MAP REVISED 03/05/18 TO SHOW ADDITIONAL RECOVERED CORNERS ON 03/03/2018.
0000000 0000W3
24 6 5 S1TOCKTON DRIVE, FLEMING ISLAND, FL 32003
OFFICE: 904-234-5574 / cporter@porteriss.com
THIS 01(l,lTdl SFA/ 1C APIAlf; n1CPl dVP] RV PPRAAICCInN nC rwARI Pc P ono o 01 c