Loading...
1980 MIPAULA CT RESA22-0026 FL14911_R12_AE_PER7261 SS 2020-10-21398 East Dania Beach Blvd. Suite 338 Dania Beach, FL 33004 954.399.8478 PH 954.744.4738 FX contact@buildingdrops.com Hermes F. Norero, P.E. Florida P.E. No. 73778 BUILDING DROPS A Perfect Solution in Every Drop! Certificate of Authorization: 29578 Product Evaluation Report of American Craftsman Windows Silver Line Windows and Doors 50 Series / V1 Series / (2200 / 2300) Single-Hung Windows (NON-HVHZ) (NON-IMPACT) for Florida Product Approval FL# FL14911 Report No. 7261 Current Florida Building Code Method: 1 – D (Engineering Evaluation) Category: Windows Sub – Category: Single Hung Product: 50 Series / V1 Series / (2200 / 2300) Single- Hung Windows Material: Vinyl Product Dimensions: See Installation Instructions, SWD019 Prepared for: Silver Line Windows and Doors One Silverline Dr. North Brunswick, NJ 08902 Prepared by: Hermes F. Norero, P.E. Florida Professional Engineer # 73778 Date: 10/14/2020 Contents: Evaluation Report Pages 1 – 3 Digitally signed by Hermes F Norero Reason: I am approving this document Date: 2020.10.22 02:29:32 +02'00' FL#: FL14911 Date: 10/14/20 Report No: 7261 Hermes F. Norero, P.E. Florida P.E. No. 73778 Page 2 of 3 BUILDING DROPS A Perfect Solution in Every Drop! Certificate of Authorization: 29578 Certificate of Authorization: 29578 Manufacturer: Silver line Windows & Doors Product Category: Windows Product Sub-Category: Single Hung Compliance Method: State Product Approval Method (1)(d) Product Name: 50 Series / V1 Series / (2200 / 2300) Single-Hung Windows (NON-HVHZ) (NON-IMPACT) Scope: This is a Product Evaluation Report issued by Hermes F. Norero, P.E. (FL # 73778) for Silver Line Windows and Doors based on Method 1d of the State of Florida Product Approval, Florida Department of Business and Professional Regulation - Florida Building Commission. Hermes F. Norero, P.E. does not have nor will acquire financial interest in the company manufacturing or distributing the product or in any other entity involved in the approval process of the product named herein. This product has been evaluated for use in locations adhering to the current Florida Building Code. See Installation Instructions SWD019, signed and sealed by Hermes F. Norero, P.E. (FL # 73778) for specific use parameters. Limits of Use: 1. This product has been evaluated and is in compliance with the current Florida Building Code, excluding the “High Velocity Hurricane Zone” (HVHZ). 2. Product anchors shall be as listed and spaced as shown on details. Anchor embedment into substrate material shall be beyond wall dressing or stucco. 3. When used in areas requiring wind borne debris protection this product complies with Chapter 16 of the current Florida Building Code and does require an impact resistant covering. 5. Site conditions that deviate from the details of Installation Instructions SWD019 require further engineering analysis by a licensed engineer or registered architect. 6. See Installation Instructions SWD019 for size and design pressure limitations. FL#: FL14911 Date: 10/14/20 Report No: 7261 Hermes F. Norero, P.E. Florida P.E. No. 73778 Page 3 of 3 BUILDING DROPS A Perfect Solution in Every Drop! Certificate of Authorization: 29578 Certificate of Authorization: 29578 Quality Assurance Entity: The manufacturer has demonstrated compliance of products in accordance with the Florida Building Code for manufacturing under a Quality Assurance Entity through Window and Door Manufacturers Association (FBC Organization #QUA2515). Performance Standards: The product described herein has been evaluated per: • AAMA/WDMA/CSA 101/I.S.2/A440-08/11 Referenced Data: 1. Product Testing performed by Architectural Testing, Inc. (FBC Organization # TST1795) Report #: G0995.01-109-47 Report Date: 07/27/2016 Report #: D0714.01-109-47 Report Date: 09/27/2013 Report #: D0990.01-109-47 Report Date: 10/07/2013 Report #: C7069.01-109-47 Report Date: 05/14/2013 Report #: H2545.01-201-47 Report Date: 06/14/2017 Report #: C6383.01-109-47 Report Date: 11/12/2013 Report #: H0480.01-201-47 Report Date: 04/26/2017 Report #: F9655.01-109-47 Report Date: 07/21/2016 2. Quality Assurance Entity Window and Door Manufacturers Association (FBC Organization #QUA2515) Installation Method: Please refer to installation instructions, SWD019, for anchor methods, selection, spacing, edge distances, embedment’s and further details of installation. Design Pressure: Please refer to installation instructions, SWD019, for mull combination grouping, configurations, and corresponding design pressures.