1980 MIPAULA CT RESA22-0026 JOHNSON ARCH DWGSJOHNSON RESIDENCE1980 MIPAULA COURTATLANTIC BEACH, FL 32233JNOverby, LLC
Architectural and Interior Design
Julianne N. Overby, R.A.
2452 Pullian Street
Jacksonville Beach, Florida 32250
904-704-8628
Email: jno@jnoverby.com
FL. AR-0017060 FL. ID-4621
NOTE:
DO NOT SCALE DRAWINGS.
IF PRINTED ON 11"X17"
MEDIA, DRAWING SCALE
IS HALF-SIZED.
DATE ISSUED:
OCTOBER 14, 2022
PERMIT SET
T1
TITLE
SHEET
BUILDING CODE SUMMARY
CODE ENFORCEMENT JURISDICTION:
CITY OF ATLANTIC BEACH
OCCUPANCY CLASSIFICATION: RESIDENTIAL (R-3)
BUILDING CODE:
CONSTRUCTION TYPE: TYPE V-B (WOOD FRAME)
SPRINKLED: NO
FIRE DISTRICT: NO
WORK AREA-
EXISTING A/C AREA:2,029 S.F.
NEW ADDITION 2ND FLOOR:1,197 S.F.
NEW ADDITION 1ST FLOOR: 89 S.F.
TOTAL NEW A/C AREA:3,315 S.F.
EXISTING FRONT PORCH: 54 S.F.
FRONT PORCH ADDITION:102 S.F.
TOTAL NEW FRONT PORCH:156 S.F.
PROVIDE INSULATION PER CODE
R-38 IN CEILING, R-13 IN WALLS
ALTERATION LEVEL: 2
Florida Building Code 7th Edition (2020) Building
Florida Building Code 7th Edition (2020) Residential
Florida Building Code 7th Edition (2020) Plumbing
National Electric Code 2014 - NFPA 70-2011
Florida Building Code 7th Edition (2020)
Energy Conservation
Florida Building Code 7th Edition (2020) Mechanical
Florida Fire Prevention Code 7th Edition
ARCHITECTURAL DRAWINGS:
T1 TITLE SHEET
D1 DEMOLITION PLAN
A1 NEW FIRST FLOOR PLAN
A2 NEW SECOND FLOOR PLAN
A3 EXTERIOR ELEVATIONS
A4 EXTERIOR ELEVATIONS
A5 ROOF PLAN AND DETAILS
A6 FIRST FLOOR ELECTRICAL LAYOUT PLAN
A7 SECOND FLOOR ELECTRICAL LAYOUT PLAN
DRAWING INDEX
JOHNSON RESIDENCE RENOVATION
1980 MIPAULA COURT
ATLANTIC BEACH, FLORIDA 32233
FRONT ELEVATION
NEW
SECOND FLOOR
ADDITION
AT
EXISTING
FOOTPRINT
LOT COVERAGE:
TOTAL LOT 10,719 S.F.
HOUSE 2,633 S.F.
DRIVEWAY & WALK 880 S.F.
POOL DECK 1,185 S.F.
SHED 66 S.F.
A/C POOL PADS 18 S.F.
TOTAL IMPERVIOUS 4,782 S.F. (45%)
EXISTING SITE PLAN TO REMAIN
NO CHANGE TO SITE PLAN
OR IMPERVIOUS CALCULATIONS
Julianne
N. Overby
Digitally signed by
Julianne N. Overby
Date: 2022.10.14
15:35:41 -04'00'
By Toni Gindlesperger at 5:08 pm, Oct 26, 2022
By Mike Jones at 3:08 pm, Oct 31, 2022
JOHNSON RESIDENCE1980 MIPAULA COURTATLANTIC BEACH, FL 32233JNOverby, LLC
Architectural and Interior Design
Julianne N. Overby, R.A.
2452 Pullian Street
Jacksonville Beach, Florida 32250
904-704-8628
Email: jno@jnoverby.com
FL. AR-0017060 FL. ID-4621
NOTE:
DO NOT SCALE DRAWINGS.
IF PRINTED ON 11"X17"
MEDIA, DRAWING SCALE
IS HALF-SIZED.
DATE ISSUED:
OCTOBER 14, 2022
PERMIT SET
D1
DEMOLITION
PLAN
GENERAL DEMOLITION NOTES:
1.ALL DEMOLITION WORK TO BE PERFORMED UNDER G.C. CONTRACT. G.C. TO FIELD VERIFY ALL EXISTING CONDITIONS.
2.SURVEY EXISTING CONDITIONS OF THE BUILDING TO DETERMINE IF REMOVING ANY ELEMENT MIGHT RESULT IN STRUCTURAL
DEFICIENCY TO ANY PORTION OF THE STRUCTURE OR ADJACENT STRUCTURES. NOTIFY THE ARCHITECT AND STRUCTURAL
ENGINEER IN WRITING PRIOR TO COMMENCING ANY ADDITIONAL WORK FOR DIRECTION IF DEFICIENCIES ARE NOTED.
3.TURN OFF NECESSARY POWER AND UTILITIES PRIOR TO COMMENCING ANY DEMOLITION WORK.
4.ITEMS INDICATED TO BE REMOVED SHALL BE REMOVED AND LEGALLY DISPOSED OF IN ACCORDANCE WITH APPLICABLE CODES.
5.PROTECT EXISTING ITEMS TO REMAIN. THESE ITEMS TO BE COORDINATED WITH THE OWNER PRIOR TO ANY DEMO WORK.
6.DEMO AND REMOVE EXISTING INTERIOR DOOR / DOOR FRAME / DOOR SILL / CASING UNLESS OTHERWISE NOTED (U.O.N) ON PLAN.
7.CUT OPENINGS NEATLY AND HOLES PLUMB, SQUARE AND TRUE TO DIMENSIONS REQUIRED. USE CUTTING METHODS LEAST LIKELY
TO DAMAGE CONSTRUCTION TO REMAINING OR ADJOINING CONSTRUCTION.
8. ANY FIRE EXTINGUISHERS TO BE REMOVED AND STORED FOR FUTURE USE.
9. AUTHORIZED CONSTRUCTION PERSONNEL ONLY WITHIN THE CONSTRUCTION AREA.
10. WORK TO BE DONE IN SUCH A MANNER AS TO HAVE MINIMUM DISRUPTION TO ONGOING CITY BUSINESS AND PARKING LOT.
11. CODES AND REGULATIONS: COMPLY WITH GOVERNING CODES AND REGULATIONS.
12. USE EXPERIENCED WORKERS.
13. OCCUPANCY: IMMEDIATE AREAS OF WORK MAY BE OCCUPIED DURING DEMOLITION BY THE HOME OWNERS.
14. DEMOLISH DESIGNATED IMPROVEMENTS AS NECESSARY TO IMPLEMENT RENOVATION PLAN.
15. IMPLEMENT POLLUTION CONTROL DURING BUILDING DEMOLITION.
16. HAZARDOUS MATERIALS: IF HAZARDOUS MATERIALS ARE NOTED THEY WILL BE REMOVED UNDER
SEPARATE CONTRACT. NOTIFY OWNER IF HAZARDOUS MATERIAL IS DISCOVERED TO BE PRESENT.
17. DO NOT DAMAGE BUILDING ELEMENTS AND IMPROVEMENTS INDICATED TO REMAIN. ITEMS OF SALVAGE
VALUE, NOT SPECIFIED ITEMS TO BE RETURNED TO OWNER, SHALL BE REMOVED FROM STRUCTURE.
STORAGE OR SALE OF ITEMS IS PROHIBITED.
18. UTILITIES: LOCATE, IDENTIFY, DISCONNECT, AND SEAL OR CAP OFF UTILITIES IN AREAS TO BE DEMOLISHED.
19. SHORING AND BRACING: PROVIDE AND MAINTAIN INTERIOR AND EXTERIOR SHORING AND BRACING AS
REQUIRED.
20. OCCUPIED SPACES: DO NOT CLOSE OR OBSTRUCT STREETS, WALKS, DRIVES, PARKING SPACES OR OTHER
OCCUPIED OR USED SPACES OR FACILITIES WITHOUT THE WRITTEN PERMISSION OF THE OWNER AND THE
AUTHORITIES HAVING JURISDICTION. DO NOT INTERRUPT UTILITIES SERVING OCCUPIED OR USED FACILITIES
WITHOUT THE WRITTEN PERMISSION OF THE OWNER AND AUTHORITIES HAVING JURISDICTION. IF
NECESSARY, PROVIDE TEMPORARY UTILITIES.
21. RESTORATION: RESTORE FINISHES OF PATCHED AREAS.
1/4" = 1'-0"
DEMOLITION FLOOR PLAN
AC
WH
PANTRY
REF
REMOVE EXISTING
KITCHEN FIXTURES
AND WALLS FOR NEW
LAYOUT
REMOVE
WALLS & DOORS
RELOCATE W&D
4'-0"
REMOVE
EXISTING
KITCHEN
WALLS &
WINDOWS
5'-4" NEW OPENING
RELOCATE
EXISTING
HWH
REMOVE
EXISTING
DOOR
REMOVE
EXISTING DOOR &
RELOCATE
NEW DOORS REMOVE
EXISTING
EXTERIOR
WALL
REMOVE
EXISTING
WALLS &
DOORS
REMOVE
EXISTING
CLOSET
REMOVE
EXISTING FIREPLACE
FOR NEW FIREPLACE
LOCATION
REMOVE
EXISTING
CLOSET
REMOVE
EXISTING
WINDOW
REMOVE EXISTING
EXTERIOR WALL
& WINDOWS
REMOVE EXISTING
WALLS
& WINDOWS
REMOVE
EXISTING
DOOR Julianne
N. Overby
Digitally signed
by Julianne N.
Overby
Date: 2022.10.14
15:35:52 -04'00'
JOHNSON RESIDENCE1980 MIPAULA COURTATLANTIC BEACH, FL 32233JNOverby, LLC
Architectural and Interior Design
Julianne N. Overby, R.A.
2452 Pullian Street
Jacksonville Beach, Florida 32250
904-704-8628
Email: jno@jnoverby.com
FL. AR-0017060 FL. ID-4621
NOTE:
DO NOT SCALE DRAWINGS.
IF PRINTED ON 11"X17"
MEDIA, DRAWING SCALE
IS HALF-SIZED.
DATE ISSUED:
OCTOBER 14, 2022
PERMIT SET
A1
NEW
FIRST
FLOOR
PLAN
GENERAL NOTES:
1. ALL WORK TO BE DONE IN ACCORDANCE TO THE MOST RECENT EDITION OF FLORIDA
BUILDING CODES AND ALL OTHER APPLICABLE NATIONAL, STATE AND LOCAL CODES AND
ORDINANCES.
2. VERIFY ALL EXISTING CONDITIONS AND MEASUREMENTS IN FIELD PRIOR TO
CONSTRUCTION. VERIFY LAYOUT WITH REFERENCE TO EXISTING CONDITIONS. ANY
DISCREPANCIES SHALL BE COMMUNICATED IN WRITING TO THE ARCHITECT BEFORE
CONSTRUCTION PROCEEDS.
3. IT IS THE BUILDER'S RESPONSIBILITY TO ASSURE THAT ALL WORK IS IN STRICT
ACCORDANCE WITH THE LATEST EDITION OF ALL APPLICABLE CONSTRUCTION
STANDARDS.
4. ALL DIMENSIONS ARE TO FACE OF DRYWALL OR CENTERLINE OF STRUCTURE UNLESS
OTHERWISE NOTED.
5. FLOOR PENETRATIONS TO BE WATERPROOFED.
6. ALL INTERIOR WALLS TO BE WOOD STUDS UNLESS OTHERWISE NOTED.
7. WHERE G.C. IS TO PROVIDE TYPE 'X' GYP. BD. FOR A RATED ASSEMBLY, THE TYPE 'X'
GYP. BD. IS REQUIRED TO GO BENEATH THE SHEATHING AND FINISHES.
8. INTERIOR DOORS ARE TO BE 5" OFF PERPENDICULAR WALLS UNLESS OTHERWISE
NOTED.
9. IT IS THE BUILDER'S RESPONSIBILITY TO ASSURE THAT ALL MANUFACTURED ARTICLES,
MATERIAL AND EQUIPMENT ARE APPLIED, INSTALLED, CONNECTED, ERECTED, USED,
CLEANED, ADJUSTED, OPERATED AND CONDITIONED AS DIRECTED BY THE
MANUFACTURERS, UNLESS HEREIN SPECIFIED TO THE CONTRARY. BUILDER SHALL
FOLLOW ALL INSTRUCTIONS TO SUSTAIN AND PRESERVE ALL EXPRESSED OR IMPLIED
WARRANTIES AND GUARANTEES.
10. IT IS THE BUILDER'S RESPONSIBILITY TO CHECK ALL PLAN DIMENSIONS & DETAILS FOR
OVERALL ACCURACY APPROPRIATE TO THE SITE & FINAL SELECTION OF MASONRY, FLOOR
JOISTS, LUMBER, STRUCTURAL MEMBERS, VENEER, ROOFING, ETC.
11. SUBSTITUTES FOR SPECIFIC MATERIALS & MANUFACTURERS SHOWN ON THESE PLANS
MAY BE OFFERED, BUT MUST BE APPROVED IN WRITING BY THE ARCHITECT AND OWNER
PRIOR TO PROCURING OR INSTALLING.
12. RESPONSIBILITY OF THE GC INCLUDES, BUT IS NOT LIMITED TO, PROPER INSTALLATION
OF MATERIALS, NAILING, GLUING, CAULKING, INSULATING, FLASHING, ROOFING,
WEATHERPROOFING & ANY OTHER SMALL ITEMS OR DETAILS NOT NECESSARILY
INDICATED ON THE PLANS.
13. THESE PLANS ARE NOT INTENDED TO BE COMPLETE IN ALL DETAILS OF
WEATHERPROOFING. USE OF A VARIETY OF DIFFERENT MATERIALS CAN CHANGE DETAILS.
ADDITIONALLY, VARYING CODES & REGULATIONS, FOUNDATION REQUIREMENTS,
ELECTRICAL AND MECHANICAL PLANS CAN CHANGE THESE DETAILS.
14. FURNITURE TO BE COORDINATED, INSTALLED AND SCHEDULED BY G.C. AND THE
OWNER
15. ALL KITCHEN APPLIANCES INSTALLED TO BE COORDINATED AND SCHEDULED BY G.C.
16. G.C. TO SCHEDULE & COORDINATE THE INSTALLATION OF OWNER PROVIDED ITEMS,
INCLUDING, BUT NOT LIMITED TO, FURNITURE & AUDIO/VIDEO SYSTEMS.
A
A31/4" = 1'-0"
FIRST FLOOR PLAN
GARAGE
BEDROOM #3BEDROOM #2
EXTENDED
FRONT PORCH
FOYER
BATH #2
MASTER
BEDROOM
AC
MUD
ROOM
FAMILY ROOM
BATH #1
PLANTER
D
A4
C
A3
B
A3
INFILL FLOOR TO ALIGN
W/ EXISTING FINISHED
FLOOR LEVEL
MASTER
CLOSET
EXTENDED
KITCHEN
DRYER
WASHER 10'-0" ISLAND4'-0"16'-6"WALL
OVEN
5'-6"
5'-0"3'-0"4'-0"3'-0"12'-0" SLIDER WINDOWS
1593'-6"12'-0" SLIDER WINDOWS(2) 3'-6"x6' WINDOWS7'-712"
3'-6"4'-0"REF
2'-6"7'-0"3'-6"13'-0"7'-0"DINING
3/07'-412"7'-412" BEVERAGE3/0
10'-6"
WH
STORAGE
UNDER STAIR
5/0
RELOCATE
ELECT
PANEL GASFIREPLACE3'-0"10'-0"
20'-0" WIDEN EXISTING DRIVEWAY
10'-0"4'-0" HALLWAY3'-6"PANTRY
2/8
8'-5"4'-0"3'-6"DROP ZONE9'-0"DOG
BATH 5'-0"DW
2'-4"10'-8"2'-4"
3/0
7'-1012"POT
FILLER
WINE
COOLER
ICE
5'-0"2'-6"7'-1012"
2/8
18" D.LINENCABINET6'-0"3'-0"6'-0"2'-4"1'-0"8'-8"1'-0"2'-4"1'-0"6'-0" EXISTING PORCH2/8
8'-612" NEW VANITY
1'-0"x3'-6"
WINDOW
1'-0"x3'-6"
WINDOW
6'-412"
Julianne
N. Overby
Digitally signed by
Julianne N. Overby
Date: 2022.10.14
15:36:01 -04'00'
JOHNSON RESIDENCE1980 MIPAULA COURTATLANTIC BEACH, FL 32233JNOverby, LLC
Architectural and Interior Design
Julianne N. Overby, R.A.
2452 Pullian Street
Jacksonville Beach, Florida 32250
904-704-8628
Email: jno@jnoverby.com
FL. AR-0017060 FL. ID-4621
NOTE:
DO NOT SCALE DRAWINGS.
IF PRINTED ON 11"X17"
MEDIA, DRAWING SCALE
IS HALF-SIZED.
DATE ISSUED:
OCTOBER 14, 2022
PERMIT SET
A2
NEW
SECOND
FLOOR
PLAN
1/4" = 1'-0"
SECOND FLOOR PLAN
BONUS ROOM
11'-10"STORAGE
OR OFFICE/WORK
SPACE
2/8
2/8
6'-0" VANITY2/8
2/87'-6"3'-6"6'-10"2/8
BEDROOM 1
BEDROOM 2
BATHHALF
BATH 6'-5"2/8
CLOSET 1
CLOSET 2
7'-0" MEDIA WALL
7'-7" BUILT-IN KITCHENETTE2/8
5'-6"12'-5"
5'-0"5'-0"
21'-0" ALIGN W/ FLOOR BELOW
11'-5"5'-6"
12'-5"3'-6"12'-0"3'-6"3'-0"6'-6"4'-6"6" WALL6" WALL
2/8
93'-6"3'-6"3'-6"121610'-11"7'-11"25'-8"18'-5"
3'-0"
2/8
5'-8"
3'-5"3'-11"10'-11"8'-0"3'-5"2'-6"2'-6"4'-0"
9'-8"37'-8"2'-6"2'-6"
4'x4' WINDOW 4'x4' WINDOW (3) 2'x2'-6" WINDOWS 4'x5' EGRESS4'x2'-6" WINDOW4'x5' EGRESS
(3) 2'x2'-6" WINDOWS6'-5"4'x5' WINDOW15'-4"9'-6"4'x5' WINDOW9'-512"4'x5' WINDOW3'-4"4'-2"3'-10"4'x4'-6" WINDOWU.C.
REF
1718Julianne
N. Overby
Digitally signed by
Julianne N. Overby
Date: 2022.10.14
15:36:10 -04'00'
A3
EXTERIOR
ELEVATIONSJOHNSON RESIDENCE1980 MIPAULA COURTATLANTIC BEACH, FL 32233JNOverby, LLC
Architectural and Interior Design
Julianne N. Overby, R.A.
2452 Pullian Street
Jacksonville Beach, Florida 32250
904-704-8628
Email: jno@jnoverby.com
FL. AR-0017060 FL. ID-4621
NOTE:
DO NOT SCALE DRAWINGS.
IF PRINTED ON 11"X17"
MEDIA, DRAWING SCALE
IS HALF-SIZED.
DATE ISSUED:
OCTOBER 14, 2022
PERMIT SETSCALE:
LEFT ELEVATION
1/4" = 1'-0"
B
A3
6
12
10'-0" FIRST FLOOR CEILING1'-6"10'-0" SECOND FLOOR CEILING8'-0" TOP OF WINDOWS8'-0" TOP OF WINDOWS5'-6" WINDOWSSCALE:
FRONT ELEVATION
1/4" = 1'-0"
A
A3
6
12
10'-0" FIRST FLOOR CEILING1'-6"10'-0" SECOND FLOOR CEILING8'-0" TOP OF WINDOWS10'-0"30'-7" ABOVE FINISHED GRADE4'-0"2'-6"Julianne
N. Overby
Digitally signed by
Julianne N. Overby
Date: 2022.10.14
15:36:18 -04'00'
A4
EXTERIOR
ELEVATIONSJOHNSON RESIDENCE1980 MIPAULA COURTATLANTIC BEACH, FL 32233JNOverby, LLC
Architectural and Interior Design
Julianne N. Overby, R.A.
2452 Pullian Street
Jacksonville Beach, Florida 32250
904-704-8628
Email: jno@jnoverby.com
FL. AR-0017060 FL. ID-4621
NOTE:
DO NOT SCALE DRAWINGS.
IF PRINTED ON 11"X17"
MEDIA, DRAWING SCALE
IS HALF-SIZED.
DATE ISSUED:
OCTOBER 14, 2022
PERMIT SETSCALE:
RIGHT ELEVATION
1/4" = 1'-0"
D
A4 2'-0"2'-6"10'-0" FIRST FLOOR CEILING1'-6"10'-0" SECOND FLOOR CEILING8'-0" TOP OF WINDOWS8'-0" TOP OF WINDOWS4'-6"5'-0"SCALE:
REAR ELEVATION
1/4" = 1'-0"
C
A4 8'-0"6
12
5'-6"2'-6"10'-0" FIRST FLOOR CEILING1'-6"10'-0" SECOND FLOOR CEILING8'-0" TOP OF WINDOWS8'-0" TOP OF WINDOWSJulianne
N. Overby
Digitally signed by
Julianne N. Overby
Date: 2022.10.14
15:36:27 -04'00'
JOHNSON RESIDENCE1980 MIPAULA COURTATLANTIC BEACH, FL 32233JNOverby, LLC
Architectural and Interior Design
Julianne N. Overby, R.A.
2452 Pullian Street
Jacksonville Beach, Florida 32250
904-704-8628
Email: jno@jnoverby.com
FL. AR-0017060 FL. ID-4621
NOTE:
DO NOT SCALE DRAWINGS.
IF PRINTED ON 11"X17"
MEDIA, DRAWING SCALE
IS HALF-SIZED.
DATE ISSUED:
OCTOBER 14, 2022
PERMIT SET
A5
ROOF
PLAN
AND
DETAILS
ROOF VENTS/PENETRATIONS:
ALL RIDGE VENTS AND PENETRATIONS TO BE INSTALLED PER THE MANUFACTURER'S
RECOMMENDATIONS-
APPLY ROOFNG CEMENT OR SELF ADHERING FLASHING OVER VENT FLANGE AT THE HEAD
INSTALL SHINGLE OVER THE VENT FLANGE HEAD
ROOF PLAN NOTES:
1. DO NOT SCALE DRAWINGS.
2. IF DIMENSIONS ARE IN QUESTION, THE ROOFER SHALL BE RESPONSIBLE FOR OBTAINING
CLARIFICATION BEFORE CONTINUING WITH CONSTRUCTION
3. BUILDER SHALL VERIFY ALL DIMENSIONS & CONDITIONS AT JOBSITE.
4. SEE FLOOR PLAN FOR BUILDING DIMENSIONS.
5. ALL ROOFING AND ROOFING DETAILS SHALL BE INSTALLED IN STRICT ACCORDANCE WITH INDUSTRY
STANDARDS AND MANUFACTURER'S INSTRUCTIONS.
6. ROOFING SUBCONTRACTOR SHALL HAVE APPROPRIATE LICENSE(S) AS REQUIRED IN JURISDICTION OF
CONSTRUCTION.
7. NO WORK SHALL CONFLICT WITH THE MANUFACTURER'S GUARANTEE OR WARRANTY.
8. WRITTEN WARRANTY SHALL BE PROVIDED TO OWNER AND INCLUDED IN THE CLOSE OUT DOCUMENTS
PROVIDED BY GC.
9. PROVIDE FLASHING AS PER DETAILS OR AS PER SMACNA IF NO DETAILS ARE SHOWN WHERE ROOF
PITCH CHANGES OR WHERE ROOFING INTERSECTS WITH VERTICAL SURFACES.
10. THE INSTALLATION SUBCONTRACTOR SHALL BE FULLY RESPONSIBLE FOR ALL ROOFING WORK .
11. ALL EXHAUST FAN, VENT, FLUE & STACK OPENINGS ARE TO BE CUT & SEALED BY BUILDER.
12. ROOF VENT TERMINALS SHALL BE 12' AWAY FROM AND 2' ABOVE ANY AIR INTAKE, DOOR OR
WINDOW, 18" AWAY FROM ANY VERTICAL WALL EXTENDING ABOVE ROOF VENT, AND NOT BELOW ANY
ROOF EAVE, OR AS REQUIRED BY LOCAL CODES.
NOTE: THESE DETAILS USED FOR DOORS & WINDOW. LL FLASHING TO MEET FBC R903.2.1,
R905.2.8. & R703.8 AND INSTALLED PER MANUFACTURER'S RECOMMENDATIONS.
1/4" = 1'-0"
ROOF PLAN 6:12ROOF SLOPENEW6:12ROOF SLOPENEW6:12ROOF SLOPEEXISTING TO REMAIN6:12
ROOF SLOPE
NEW
6:12
ROOF SLOPE
NEW
6:12
ROOF SLOPE
NEW
6:12
ROOF SLOPE
EXISTING TO REMAIN
6:12
ROOF SLOPE
EXISTING TO REMAIN
6:12
ROOF SLOPE
EXISTING TO REMAIN
6:12ROOF SLOPEEXISTING TO REMAIN6:12ROOF SLOPEEXISTING TO REMAIN6:12ROOF SLOPEEXISTING TO REMAIN6:12
ROOF SLOPE
NEW
6:12
ROOF SLOPE
NEW
1'-6"1'-6"1'-6"1'-6"1'-6"1'-6"1'-6"1'-6"1'-6"1'-6"1'-6"1'-6"1'-6"1'-6"SCALE:
TYP. WALL SECTION
3/4" = 1'-0"
1
A5
NOTE:
ALL STRUCTURAL SIZES TO BE VERIFIED WITH LICENSED
STRUCTURAL ENGINEER OF RECORD FOR THIS PROJECT.
THESE WALL SECTIONS SHOWN FOR DESIGN INTENT.10'-0" EXISITNG CEILINGMAXIMIZE CEILING WITH JOISTS TO ALIGN W/ EXISTING FINISHED FLOORNOTE:
METAL DRIP EDGE TO OVERLAP
3"MIN. AND EXTEND 1/2"MIN.
BELOW SHEATHING AND
EXTEND BACK ON THE ROOF 2" MIN.
INSTALL OVER UNDERLAYMENT
WITH A 4"MIN. WIDTH OF ROOF
CEMENT INSTALLED OVER THE
DRIP EDGE FLANGE.
MECHANICALLY FASTEN THE
DRIP EDGE @12" O.C. MAX.
TO MEET CODE.
FLOOR JOISTS
SEE STRUCTURAL10'-1 1/2" CEILING1/2" GYP. BOARD
OVER FRAMING W/
R-13 INSULATION
EXISTING 4" CONCRETE SLAB OVER
VAPOR BARRIER
TO REMAIN
EXISTING FOOTING TO REMAIN
2x WOOD FRAME SPECIFIED
BY STRUCTURAL ENGINEER
WITH 7/16" OSB OR ZIP
SHEATHING AND HOUSE
WRAP APPLIED TO OSB PER
MANUFACTURER'S
RECOMMENDATIONS WITH
BOARD & BATTEN SIDING
EXISTING WALLS
TO REMAIN
DRIP EDGE AT BRICK LEDGER
SLOPED TO PREVENT
PONDING
EXISTING BRICK
VENEER TO REMAIN
R-13 INSULATION
2'-0"
MATCH EXISTING
OVERHANG
METAL ROOF
ON 15# ROOFING
FELT OVER 7/16"
EXT. SHEATHING
12
6
R-38 INSULATION
1/2" GYP. BOARD
METAL DRIP
OVER FASCIA
OVER 2X6 SUB
FASCIA MATCH
EXISTING TRIM
PRE-ENGINEERED
WOOD TRUSSES
1"7 5/8"11"
SCALE:
STAIR DETAIL
1/4" = 1'-0"
2
A5
CONFIRM TO
MATCH
EXISTING
Julianne
N. Overby
Digitally signed by
Julianne N. Overby
Date: 2022.10.14
15:36:37 -04'00'
JOHNSON RESIDENCE1980 MIPAULA COURTATLANTIC BEACH, FL 32233JNOverby, LLC
Architectural and Interior Design
Julianne N. Overby, R.A.
2452 Pullian Street
Jacksonville Beach, Florida 32250
904-704-8628
Email: jno@jnoverby.com
FL. AR-0017060 FL. ID-4621
NOTE:
DO NOT SCALE DRAWINGS.
IF PRINTED ON 11"X17"
MEDIA, DRAWING SCALE
IS HALF-SIZED.
DATE ISSUED:
OCTOBER 14, 2022
PERMIT SET
A6
FIRST FLOOR
ELECTRICAL
LAYOUT
PLAN
ELECTRICAL LAYOUT PLAN NOTES:
1. VERIFY ALL EXISTING CONDITIONS.
2. COORDINATE LIGHT FIXTURE LOCATIONS CONTRACTOR ANY
DISCREPANCIES SHALL BE COMMUNICATED TO THE ARCHITECT
BEFORE CONSTRUCTION PROCEEDS FOR COORDINATION.
3. LIGHT FIXTURES SHALL BE LOCATED AS CLOSELY AS POSSIBLE TO
LOCATIONS SHOWN ON THIS PLAN.
4. FIXTURES SHALL ALIGN WITH OR CENTER ON EACH OTHER OR
WITH ADJACENT ARCHITECTURAL ELEMENTS.
5. COORDINATE LOCATION OF LIGHT FIXTURES WITH HVAC GRILLS
SO THAT THEY ALIGN WITH OR ARE SYMMETRICAL WITH EACH OTHER
WHERE THERE MAY BE CONFLICTS.
6. GRILLS & REGISTERS SHALL BE BLOCKED AS REQUIRED SO THAT
THEY CAN ALIGN WITH LIGHT FIXTURES.
7. LIGHT FIXTURE & SWITCH LOCATIONS SHALL BE REVIEWED &
APPROVED BY OWNER OR DESIGNER BEFORE INSTALLATION OF
SHEET ROCK OR OTHER WALL & CEILING FINISHES.
8. SWITCHES SHALL BE LOCATED ADJACENT TO, BUT NOT
INTERSECTING DOOR CASING OR TRIM.
9. GROUPED SWITCHES SHALL BE GANGED TIGHT TOGETHER &
SHALL BE COVERED WITH A SINGLE PLATE DESIGNED FOR THAT
PURPOSE.
10. SWITCHES SHALL TYPICALLY BE MOUNTED 48" A.F.F. TO CENTER
OF THE SWITCH.
11. SUPPORT ALL FIXTURES FROM STRUCTURE OF BUILDING.
REFER TO STRUCTURAL SHEETS FOR SPECIFIC DETAILS AS
REQUIRED FOR SPECIALTY FIXTURES.
12. VERIFY DEVICE & PLATE COLORS WITH OWNER OR DESIGNER.
13. VERIFY LIGHTING TYPE & SWITCHING.
14. FLUORESCENT LAMPS SHALL BE "WARM WHITE DELUXE"
UNLESS OTHERWISE NOTED OR SPECIFIED ON THE SCHEDULE.
15. ALL LIGHT BULBS SHALL BE COMPACT FLUORESCENT OR LED
BULBS UNLESS OTHERWISE NOTED.
16. COORDINATE THERMOSTAT AND DOORBELL LOCATIONS WITH OWNER.
TV
ELECTRICAL LEGEND
CABLE
GFI RECEPTACLE
EXTERIOR/GFI RECEPTACLE
3-WAY SWITCH
SWITCH
DUPLEX OUTLET
NOTES:
1. TELEPHONE OUTLETS TO BE 'CAT 5E' WIRE.
2. SMOKE DETECTION PER FIRE CODE.
3. SERVICE PANEL AND ELECTRIC METER
LOCATION TO BE DETERMINED W/ INPUT FROM THE
OWNER AND LOCAL UTILITY COMPANY.
4. ALL RECEPTACLE TO HAVE ARC-FAULT CIRCUIT
INTERRUPTERS PER ARTICLE 210-12.
5. HVAC DISCONNECT TO BE PROVIDED BY
MECHANICAL SUBCONTRACTOR.
6. ALL ELECTRICAL WIRING TO BE IN ACCORDANCE
WITH LATEST EDITION OF NEC AND FBC.
7. 100% OF ALL INTERIOR AND EXTERIOR
PERMANENT LIGHT FIXTURES TO USE CFL/LED
LAMPS.
COUNTERTOP HEIGHTCH
SD SMOKE DETECTOR CM
CARBON
MONOXIDE
DETECTOR
220 OUTLET
3/16" = 1'-0"
FIRST FLOOR ELECTRICAL LAYOUT PLAN
GARAGE
BEDROOM #3BEDROOM #2
EXTENDED
FRONT PORCH
FOYER
BATH #2
MASTER
BEDROOM
AC
MUD
ROOM
FAMILY ROOM
BATH #1
PLANTER
MASTER
CLOSET
KITCHEN
DINING3'-0"6'-0"
WH
PANTRY4'-6"333333333 3 3 3 3
333333 3 3 3
33333 3
CHCHCHCH5'-6" A.F.FTVCHCHCH
SD
SD
CM
CH
CHJulianne
N. Overby
Digitally signed by
Julianne N. Overby
Date: 2022.10.14
15:36:53 -04'00'
JOHNSON RESIDENCE1980 MIPAULA COURTATLANTIC BEACH, FL 32233JNOverby, LLC
Architectural and Interior Design
Julianne N. Overby, R.A.
2452 Pullian Street
Jacksonville Beach, Florida 32250
904-704-8628
Email: jno@jnoverby.com
FL. AR-0017060 FL. ID-4621
NOTE:
DO NOT SCALE DRAWINGS.
IF PRINTED ON 11"X17"
MEDIA, DRAWING SCALE
IS HALF-SIZED.
DATE ISSUED:
OCTOBER 14, 2022
PERMIT SET
A7
SECOND FLOOR
ELECTRICAL
LAYOUT
PLAN
ELECTRICAL LAYOUT PLAN NOTES:
1. VERIFY ALL EXISTING CONDITIONS.
2. COORDINATE LIGHT FIXTURE LOCATIONS CONTRACTOR ANY
DISCREPANCIES SHALL BE COMMUNICATED TO THE ARCHITECT
BEFORE CONSTRUCTION PROCEEDS FOR COORDINATION.
3. LIGHT FIXTURES SHALL BE LOCATED AS CLOSELY AS POSSIBLE TO
LOCATIONS SHOWN ON THIS PLAN.
4. FIXTURES SHALL ALIGN WITH OR CENTER ON EACH OTHER OR
WITH ADJACENT ARCHITECTURAL ELEMENTS.
5. COORDINATE LOCATION OF LIGHT FIXTURES WITH HVAC GRILLS
SO THAT THEY ALIGN WITH OR ARE SYMMETRICAL WITH EACH OTHER
WHERE THERE MAY BE CONFLICTS.
6. GRILLS & REGISTERS SHALL BE BLOCKED AS REQUIRED SO THAT
THEY CAN ALIGN WITH LIGHT FIXTURES.
7. LIGHT FIXTURE & SWITCH LOCATIONS SHALL BE REVIEWED &
APPROVED BY OWNER OR DESIGNER BEFORE INSTALLATION OF
SHEET ROCK OR OTHER WALL & CEILING FINISHES.
8. SWITCHES SHALL BE LOCATED ADJACENT TO, BUT NOT
INTERSECTING DOOR CASING OR TRIM.
9. GROUPED SWITCHES SHALL BE GANGED TIGHT TOGETHER &
SHALL BE COVERED WITH A SINGLE PLATE DESIGNED FOR THAT
PURPOSE.
10. SWITCHES SHALL TYPICALLY BE MOUNTED 48" A.F.F. TO CENTER
OF THE SWITCH.
11. SUPPORT ALL FIXTURES FROM STRUCTURE OF BUILDING.
REFER TO STRUCTURAL SHEETS FOR SPECIFIC DETAILS AS
REQUIRED FOR SPECIALTY FIXTURES.
12. VERIFY DEVICE & PLATE COLORS WITH OWNER OR DESIGNER.
13. VERIFY LIGHTING TYPE & SWITCHING.
14. FLUORESCENT LAMPS SHALL BE "WARM WHITE DELUXE"
UNLESS OTHERWISE NOTED OR SPECIFIED ON THE SCHEDULE.
15. ALL LIGHT BULBS SHALL BE COMPACT FLUORESCENT OR LED
BULBS UNLESS OTHERWISE NOTED.
16. COORDINATE THERMOSTAT AND DOORBELL LOCATIONS WITH OWNER.
TV
ELECTRICAL LEGEND
CABLE
GFI RECEPTACLE
EXTERIOR/GFI RECEPTACLE
3-WAY SWITCH
SWITCH
DUPLEX OUTLET
NOTES:
1. TELEPHONE OUTLETS TO BE 'CAT 5E' WIRE.
2. SMOKE DETECTION PER FIRE CODE.
3. SERVICE PANEL AND ELECTRIC METER
LOCATION TO BE DETERMINED W/ INPUT FROM THE
OWNER AND LOCAL UTILITY COMPANY.
4. ALL RECEPTACLE TO HAVE ARC-FAULT CIRCUIT
INTERRUPTERS PER ARTICLE 210-12.
5. HVAC DISCONNECT TO BE PROVIDED BY
MECHANICAL SUBCONTRACTOR.
6. ALL ELECTRICAL WIRING TO BE IN ACCORDANCE
WITH LATEST EDITION OF NEC AND FBC.
7. 100% OF ALL INTERIOR AND EXTERIOR
PERMANENT LIGHT FIXTURES TO USE CFL/LED
LAMPS.
COUNTERTOP HEIGHTCH
SD SMOKE DETECTOR CM
CARBON
MONOXIDE
DETECTOR
220 OUTLET
3/16" = 1'-0"
SECOND FLOOR ELECTRICAL LAYOUT PLAN
BONUS ROOM
STORAGE
OR OFFICE/WORK
SPACE
BEDROOM 1
BEDROOM 2
BATHHALF
BATH
CLOSET 1
CLOSET 212'-4"33333
33
333
333
CH
CHCHCH
5'-6" A.F.F
TV
CH
SD
SD
CM
SD
Julianne
N. Overby
Digitally signed by
Julianne N. Overby
Date: 2022.10.14
15:37:03 -04'00'